Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹16 L
EMD Value
₹16,000
Closing Date
27 Nov 2026, 6:00 pmDue today
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
MEDICAL SUPERINTENDENT, SMIMER HOSPITAL
Tender for supplying & installing equipments / instruments for Physiotherapy Department of SMIMER Hospital
363539
SMIMER/HOSPITAL/MEDICAL SUPERINTENDENT/10/2026-27
Open
Miscellaneous Works
Works
Surat
4 documents required · 4 mandatory
₹1,062
Commissioner, Surat Municipal Corporation
₹16,000
6 Nov 2026
6 Nov 2026
6 Nov 2026
27 Nov 2026
6 Nov 2026
120 days
Total Estimated Cost of Tender. Rs.16,00,000.00
Tender (Bid) Fee (Non Refundable) Rs.1,062.00/- (By DD or Pay Order Only)
Downloading of tender documents From : 06/11/2026 10.30 Hrs to
Pre-bid Conference D-Block, College Council Room, SMIMER, Opp.
Bombay Market, Umarwada, Surat on
Online submission (Last Date) On or before Dt.: 27/11/2026, upto 18:00 Hrs.
Last Date of Submission of Tender fee, On or before Dt.: 04/12/2026 up to 17.00 Hrs. To
EMD and other documents in Hard Chief Accountant, Surat Municipal Corporation,
copy. Tapipura (Muglisara), Surat-395003 Gujarat (By
R.P.A.D. / Speed Post Only) The envelope
containing the tender form should be properly
sealed and superscribed with: "Tender for
supplying & installing equipments / instruments
for Physiotherapy Department of SMIMER
Opening of online Technical Bid On Dt.: 30/11/2026 (if possible)
Opening of online price Bid Will be intimated later, if required.
The commercial bid submission should be done on the website https://smctender.nprocure.com
only before the last date & time for submission.
Price bid in physical form shall not be accepted in any case.
Submission of Tender fee, EMD and other documents in hard copy is to be done at above
mentioned address by R.P.A.D. / Speed Post only. S.M.C. shall not be responsible for any postal
Incase bidder needs any clarification or if training required for participating in online Bid, they can
contact the following office :-
nCode solution – A division of GNFC Ltd.
403, GNFC, Infotower, Bodakdev, Ahmedabad-380 054 Gujarat (India)
E-mail : [email protected] Website : www.nprocure.com
For further particulars contact above office/or visit on following website.
(i) https://nprocure.com
(ii) https://smctender.nprocure.com
MEDICAL SUPERINTENDENT
SMIMER HOSPITAL
SURAT MUNICIPAL CORPORATION
SR. PARTICULARS PAGE
1. NOTICE INVITING TENDER
2. INFORMATION OF TENDERER
3. TERMS & CONDITIONS
5. HIGHER PRICE / LOWER PRICE CERTIFICATE
6. AUTHORITY LETTER FOR SALES
7. AUTHORITY LETTER FOR AFTER SALES SERVICE
8. MANUFACTURER’S PRODUCT & SERVICE ASSURANCE
LETTER (as per tender terms no.38(b))
9. TENDER FORMAT (GENERAL)
10. SCHEDULE OF DOCUMENTS ATTACHED
11. ITEMWISE DETAILED SPECIFICATION
12. PRICE BID -
1.0 NOTICE INVITING TENDER :
(A) Tender Fee & EMD :
The tenderer should pay non-refundable tender fee Rs.1,062/- (Rupees One Thousand Sixty Two
only) and Earnest Money Deposit Rs.16,000/- by separate Demand Draft or Banker's Cheque of any
scheduled / nationalised bank payable at Surat in favour of Commissioner, Surat Municipal Corporation
in sealed envelope strictly by R.P.A.D./ Postal Speed on or before 04/12/2026 up to 17:00 hrs. to Chief
Accountant, Surat Municipal Corporation, Tapipura (Mugalisara), Surat- 395003 Gujarat. The envelope
containing the tender form should be properly sealed and superscribed with: "ONLINE TENDER
NOTICE NO. SMIMER / HOSPITAL / MEDICAL SUPERINTENDENT / 10 / 2026-27" & "TENDER
& INSTALLING EQUIPMENTS / INSTRUMENTS FOR
PHYSIOTHERAPY DEPARTMENT OF SMIMER HOSPITAL "
Tenderer should pay Earnest Money Deposit along with the submission of tender and also
invariably furnish details of EMD as mentioned. Tender/Bid without EMD or that of
insufficient amount or Non MICR DD or pay order will not be considered
(B) Security Deposit, agreement, surety & under taking:
The successful Tenderer will be required to place Security Deposit (SD) @ 5%
(Five percent) of the consideration of the contract value not more than Rs.2 Crore by
demand draft or Banker's Cheque only of any scheduled / nationalized bank payable
at Surat drawn in favour of "Commissioner, Surat Municipal Corporation" or contract
value more than Rs.2 Crore security deposit (SD) @ 5% (Five percent) should be
paid in the form of F.D.R. only of Nationalized bank of Surat Branch in the name of
Commissioner, Surat Municipal Corporation. Security deposit must be submitted
within 15 days from the date of notice of award of contract, failing which a penalty
@ 0.065% of the amount of security deposit will be imposed for delay of each day.
Upon a request received from the tenderer, EMD placed may be converted into
Security Deposit (SD). The Security Deposit will be returned after the completion of
defect liability period one / two years and after the fulfillment of obligation created
under the contract awarded.
On awarding the contract, the awardee agency will have to enter into a written
agreement using Gujarat State Stamp Paper value of Rs.300/- in case of security
deposit submitted by cash or demand draft or @ 4.90% of security deposit in case of
S.D. submitted by Fixed Deposit (FDR) at its own cost as mentioned above.
The awardee agency will have to submit third party surety on Gujarat Stamp Paper
of Rs.300/- have to produce before the undersigned.
The awardee agency will have to submit undertaking on Gujarat Stamp Paper of
Rs.300/- have to produce before the undersigned.
(C) Period of liability for defects :
12/24 Months after completion of work.
(D) Tender validity period :
The offer should be valid for acceptance for a minimum period of 120 days from the
date of opening of price bid. If needed the extension will have to be given by the
tenderer for the same period or more.
(E) Supply period and penalty for work delay :
The successful awardee must supply the equipments/ instruments as per the order and
terms & conditions as laid down in the tender within the 30 (thirty) days from the date
(after 10th (Tenth) day of issue date) of order otherwise the penalty will be imposed
@ 0.2% per day generally up to 10% of the amount of individual
equipment/instruments. The unforeseen circumstances, in the request of Tenderer
time limit may be extended by Hon. Commissioner, Surat Municipal Corporation,
depending upon the case. The request should be made before the completion of the
30 days of the date on the order.
(F) Opening of tender :
The tenders will be opened in presence of bidders & opening authority subject to
receipt of tender fee, EMD and other documents in hard copy. The tenders will be
opened in two stages i.e. technical bid & commercial bid.
(G) Purchase of tender document :
Tender documents can be downloaded from https://smctender.nprocure.com from
Dt.06/11/2026, 10.30 Hrs to Dt.27/11/2026 up to 18:00 Hrs. Submission of Tender
fee, EMD and other documents in hard copy is to be done at above mentioned address
by R.P.A.D. / Speed Post only. S.M.C. shall not be responsible for any postal delay.
(H) Instructions for Tenderer :
1. The tenders should be filled in clearly indicating the figures and its value in words too.
2. Those firms registered under small scale industries of Gujarat State and holding
subsequent registration with CSPO/NSIC for the item under tender will be eligible for
exemption from payment of Tender Fee and EMD on submission of attested copies of
their SSI & CSPO/NSIC/DGS&D registration certificates in namely [1] Tender Fee & [2]
EMD cover. Participants not covered under this category shall have to pay Tender Fee
and EMD compulsorily as prescribed, failing which the tender will be treated as rejected
at the time of opening of Bid in such cases. Technical Bid as well as Commercial Bid will
be ignored. Any basic document with regards to Tender Fee and EMD will not be
acceptable after closing time of tender.
3. DELIVERY PLACE :
Name & Address Name & Address
PHYSIOTHERAPY DEPARTMENT,
SMIMER HOSPITAL,
OPP. BOMBAY MARKET, UMARWADA,
7. Addenda & Corrigendum :
If required the Addenda and Corrigenda will be issued pursuant to the pre-bid conference
and the same will form the part of the original bid documents and shall override any
contradicting effects in the original bid document.
8. Sealing, marking and submission of the bid :
This “Technical Bid” duly filled in, sealed and superscripted as “Technical Bid, ONLINE
TENDER NOTICE NO. SMIMER / HOSPITAL / MEDICAL SUPERINTENDENT/10/
2026-27": Bid for Tender for "TENDER FOR SUPPLYING & INSTALLING
EQUIPMENTS / INSTRUMENTS FOR PHYSIOTHERAPY DEPARTMENT OF
SMIMER HOSPITAL" shall be put in a separate envelope, along with the Earnest Money
Deposit (EMD) & Bid Fee and send to:
Details to be mentioned on sealed envelope
TENDER DETAILS To,
Notice No.: SMIMER/HOSPITAL/MEDICAL The Chief Accountant,
SUPERINTENDENT/10/2026-27 Surat Municipal Corporation,
"Tender for supplying & installing equipments Mahanagar Seva Sadan,
/ instruments for Physiotherapy Department of Gordhandas Chokhawala Marg,
SMIMER Hospital " Tapipura (Muglisara), Surat - 395
Last Submission Date (Submission of Tender Gujarat, INDIA
fee, EMD & other documents in Hard copy
etc : On or before Dt.: 04/12/2026 up to
9. The tenderers are advised to read the tender documents carefully.
10. The bidder shall bear all costs associated with the preparation and submission of the bid,
including cost of presentation for the purposes of clarification of the response, if so
desired by SMIMER Hospital. SMIMER Hospital will in no case be responsible or liable
for such costs, regardless of the conduct or outcome of the evaluation process.
11. No modification should be done by the tenderer in the name of item, and in the
specifications / grade / quality / packing of the item given in the enquiry document. In
Technical Bid, all information asked / required including specification available in
offered models should be mentioned clearly. Additional specifications / features if any
available in the offered models shall be provided in additional sheet
12. No financial quotes are to be attached in Technical proposal.
13. This tender notice shall form a part of tender document.
(I) Disqualifications of Tender :
A tender shall be disqualified and will not be considered at all if :-
The Earnest Money, tender fee and affidavit is not submitted in the manner specified in
Submission of tender without document fees, EMD and Affidavit.
The tender documents submitted online, are incomplete and/or ambiguous in any respect.
The successful tenderer does not agree to deposit required amount of Security Deposit as
specified in terms and condition.
The validity period of tender specified by the tenderer is less than that specified by the
S.M.C. in Terms and Conditions.
The tender is not submitted in the manner specified in the Notice inviting the tender.
The Price Bid is submitted physically along with Technical Bid which leads to revelation of
prices before the due date of opening of the Price Bid.
Unsatisfactory past performance and manufacturing experience of tenderer.
Submission of misleading / contradictory / false statement or information and fabricated /
invalid documents.
Conditional offers or vague offers.
Items with major changes/deviations in the specification/standard packing/quality.
The tender is filled in a language other than English.
Offering an accessory as optional even though it is required to operate the instrument.
Non-submission of CMC Rates in prescribed format (in Commercial Bid).
Wherever any certificate is mentioned / specified as mandatory in the tender and is not
submitted by the tenderer.
Does not quote rates inclusive of all taxes in price bid.
Any eraser is made in the tender unauthenticated or any page or pages is/are removed or
Stipulates the validity period less than what is stated in the form or tender.
Does not disclose the full names and address of the all his partners in the case of
partnership firm.
Does not submit the tender before the stipulated time and specified date in the Account
Office as directed.
MEDICAL SUPERINTENDENT
SMIMER HOSPITAL
2.0 INFORMATION OF TENDERER
"TENDER FOR SUPPLYING & INSTALLING EQUIPMENTS / INSTRUMENTS FOR
PHYSIOTHERAPY DEPARTMENT OF SMIMER HOSPITAL"
Specimen Signature of the Tenderer
AFFIX LATEST PASSPORT SIZE PHOTOGRAPH OF ALL PARTNERS
Specimen signature of all partners incase of partnership agency.
Submission of Registered
2._____________________________ Agreement is compulsory
in case of partnership
5. Submission of GST certificate, with proof of residence is compulsory for
6. In case of Government royalty applicable to tenderer, it is compulsory to
submit a receipt of royalty payment with tender.
7. The photograph and specimen signature of contractor will be cross checked,
whenever tenderer receives payment in account section of SMC.
8. The specimen signature of tenderer will be cross checked by Account
Department of SMC, in case of representative of tenderer alongwith letter of
authority of a person who signed an agreement, receives payment.
9. All partners of tenderer should put their specimen signature at the relevant places
in the tender. A passport size photograph of all partners who have signed the
tender shall be affixed in the tender. The successful tenderer shall be required to
execute necessary agreement where in the same partners shall put on their
signatures. If required, make xerox copy of this page and attach the same duly
filled with this Tender Document.
MEDICAL SUPERINTENDENT
Signature of the Tenderer. SMIMER HOSPITAL
TERMS AND CONDITIONS
"TENDER FOR SUPPLYING & INSTALLING EQUIPMENTS / INSTRUMENTS FOR
PHYSIOTHERAPY DEPARTMENT OF SMIMER HOSPITAL"
1. The awardee agency shall have to submit a "test report" as to examination analysis
having been done regarding purity, genuineness, fitness, satisfaction of the product,
material, goods, articles supplied every time. In addition, SMC may also send the
materials supplied by the successful tenderer for test(s) / analysis to ensure that the supply
made is not of inferior standard, quality but conforming IP/BP/USP and/or BIS/ISO
standard(s) as the case be taking into consideration the specification(s). Also, the SMC will
have the right to reject the defective products, materials, goods, articles as well as the same
having working life less than the normal required time and/or the working life of the same is
falling overdue in near future and/or expiry period, date is abnormally less and falling due in
near future preventing the use, utilization of the required supplies. The awardee agency will
have to pay the cost thereof and will also have to pay the cost of products, materials, goods,
articles of inferior quality or to replace them against particular batch supplied plus such other
amount towards liquidated damages for each default and any such decision at SMC end shall
be final and binding upon the tenderer.
2. On awarding the contract, the tenderer i.e. the awardee agency if fails to fulfill the provisions
of any of the clauses to supply the products, materials, goods, articles in quantity, time and at
such rate as mentioned in work/purchase order/Notice of award of contract, fails to replace
the rejected supplies to the SMC's satisfaction, the required products, materials, goods,
articles will be procured from the open market at the risk and cost of the tenderer.
3. Tender should be faultless in figures and entirely free from erasures. Any tender
containing corrections, alterations, erasures or mistake in figures which are not purely
clerical will be rejected unless the Surat Municipal Corporation's authority directs otherwise
after personal inspection, the tender is in a language other than English and does not contain
its English translations. The tender must be quoted in figures and words and preferably type-
written otherwise the tender shall not be received for due consideration.
4. Tenderer shall sign and submit the all documents duly signed by tenderer.
5. The lowest price, rate shall not be the sole criterion but emphasis will be given on quality of
said articles required etc. After opening of price bid if the L-1 Bidder is incapable / fails to
supply the goods or provide services as per the tender terms & conditions in that case the
next lower bidders (as per chronological order) will be asked & work order will be awarded
to them at the price quoted by L-1 Bidder with the tender terms & conditions after getting
approval from competent authority of SMC.
6. "THE DELIVERY OF THE SUPPLIES WILL BE ACCEPTED ONLY DURING
OFFICE HOURS ON WORKING DAYS." ANY LOSS ARISING OUT DUE TO
NON OBSERVANCE OF THIS INSTRUCTION WILL BE BORNE BY THE
7. The tenderer/bidder shall extend all the benefits to the SMC such as free samples of products,
materials, goods, articles including any kind of discount, rebate, commission, incentives
normally offered to any other buyer in the form of gift or otherwise as part of the Sales
Promotion Scheme(s). If any such sales promotion scheme(s) is/are already launched by the
tenderer and is/are in force while the tender process is on, mention of details such scheme(s)
be made at item-7 of Tender Format (General), (If no such sales promotion scheme(s) exist
mention NIL.), if any sales promotion scheme(s) is/are launched after submission of tender
and the tenderer is awarded with the contract by the SMC, all the benefits of the said sales
promotion scheme(s) during the continuance of said scheme(s) shall have to be made
available during the period of contract.
8. Literature mentioning detailed specification of instruments/equipments and operation manual
in detail on products, materials, goods, articles quoted must be submitted along with
9. If the successful tenderer (awardee agency ) fails to ensure the required supplies in time of
specified quantity and/or quality and/or the performance of such supply/supplies is/are found
of an inferior quality, the Earnest Money Deposit ( EMD ) and /or Security Deposit ( SD )
will be forfeited at once.
10. No interest shall be paid by the Surat Municipal Corporation on Earnest Money Deposit
(EMD) as well as Security Deposit (SD).
11. Rates/Prices to be quoted should be inclusive of all Central/State taxes, custom duty,
custom clearance/handling charges, GST, local levies/fees etc. Transportation, handling
charges packing, forwarding transit losses, insurance, loading and unloading charges and all
other breakage, leakage, losses shall be borne by the tenderer.
(i) Surat Municipal Corporation does not hold "C" or "D" certificate under the Sales-Tax
(ii) Surat Municipal Corporation is a "local authority" & the procurement of products,
materials, goods, articles are going to be solely used, utilised for Medical College & public
amenities & purposes & also for relief to the poor through its various departments. Hence,
pass on benefit of exemption, concession etc., if any, in Central/State taxes, levies etc., to the
(iii) Manufacturer's name, how products, materials, goods, articles are packed vis a vis
quantity in each container shall be specified against each item while quoting the rates.
(iv) Rate must be quoted in Indian Rupees only. 100% payment will be released after
satisfactory installation & commissioning.
(v) Instrument/equipments packing should be water proof.
12. GST CLAUSE FOR CONSTRUCTION/ ERECTION/ COMMISSIONING /INSTALLATION/ REPAIRE/
MAINTENANCE/RENOVATION/ FABRICATION OF STRUCTURE INCLUDING BUILDING(MEANS
ALL WORKS CONTRACT/TURN KEY PROJECTS/SUPPLY OF MATERIAL/GOODS)
GST(Goods & Service Tax) has come in existence from 1st July,2017.Contractor/Successful
Bidder is bound to pay any amount of GST prescribed by the Govt. of India as per the
Terms of contract agreed upon during the course of execution of this Contract.
During the course of execution of contract, if there is any change in Rate of GST(Goods &
Service Tax) by the Government, the same shall be reimbursed / recovered separately by
SMC, subject to the submission of original Receipt/Proof for the amounts actually remitted
by the successful Tenderer /Contractor to the Competent Authority along with a Certificate
from Chartered Accountant of Contractor / Successful Bidder certifying that the amount of
GST paid to the Government and the same shall be intimated / submitted/claimed within
( Thirty ) Days from the date of payment. Remittance of GST within stipulated period shall
be the sole responsibility of the Successful Bidder/Contractor, failing which, SMC may
recover the amount due, from any other payable dues with SMC and decision of Municipal
Commissioner shall be final and binding on the Contractor / Successful Bidder in this
regard. Further, the non-payment of GST to the Government may lead to the termination of
the contract and forfeiture of Security Deposit / Performance Guarantee Amount.
If imposition of any other new Taxes /Duties /Levies / Cess or any other incidentals etc. or
any increase in the existing Taxes / Duties / Levies /Cess or any other incidentals
etc.(Excluding GST) are imposed during the course of the contract, the same shall be borne
by the Contractor / Successful Bidder only, in no case SMC shall be liable for the same.
The contractor will submit the invoice to the SMC having GSTIN of SMC mentioned
therein and the taxes shall be shown separately on the face of the invoice so as to claim as
13. The terms & conditions mentioned in this tender are binding to all tenderers.
CONDITIONAL TENDER WILL NOT BE ACCEPTED.
14. The tenderer should give their rate according to the specifications. Wherever the asked
equipment contains more than one component/instrument, the tenderer will preferably also
give the breakup of the total quoted cost. Tenderer should also mention the rate of any
additional options/components available for the equipment.
15. If any accessory is demanded as mandatory in the tender enquiry, under no circumstances it
should be shown as an optional accessory and quoted separately. The price of the product
offered must include the accessories required for operation of the instrument and no separate
payment will be made even if such an accessory is not included in the quotation. Only those
accessories which are specifically recommended by the manufacturer of the instrument /
equipment should be offered as part of the equipment and under no circumstances a cheaper
variety of an accessory not approved / recommended by the manufacturer should be offered.
16. Furnish photographs of all the partners, co-partners etc. in case of partnership firm or HUF as
the case may be giving signature of all them for day-to-day dealing with the SMC as well as
for obtaining payment for obligation created under this bid, in such number of sets as
required by the SMC.
17. The tenderer will have to provide on a separate letter-head details as to names and residential
addresses including phone nos. of all the partners, Karta and co-partners/beneficiaries in case
of HUF along with the tender (but not by the tenderer being legal person/entity). The
EMD/SD shall be forfeited in case the above information is not furnished during the period
of process of tender as well as throughout the period of contractual obligation. Even non-
observance of this stipulation will lead to the termination of Contract and no payment will be
made nor any damages shall be considered.
18. Tender once filled in and submitted shall not be allowed to be withdrawn till the validity of
the tender remains in force or else the EMD shall be liable for forfeiture.
19. Any monetary claim arising due to any of the terms and conditions of the tender/ supply,
including the difference arising due to risk purchase, will be recovered in the following
(a) From any pending bills of the party:
(b) From any security deposits of the party:
20. The E.M.D. / Security Deposit shall liable to be forfeited in the following circumstances
(a) Tender is rejected due to failure to furnish the requisite documents in the proper format or
giving any misleading statement or submission of false affidavit or fabricated documents.
(b) Party fails to sign the agreement for entering into contract, due to any reason whatsoever.
(c) Party fails to supply the goods / items as per the orders placed by SMIMER Hospital,
Surat Municipal Corporation.
(d) Party fails to replace the goods declared to be not of standard quality or not conforming to
acceptable standards or found to be decayed / infected /spoiled before the date of expiry have
to refund the cost of such goods.
21. Tender should not be submitted for the product/products for which the concerned/company
has been blacklisted/ debarred either by Surat Municipal corporation, GMSCL or any other
State/ Central Government and its Drug/Equipment /Instrument Procurement Agencies.
22. The concerned company/firm/bidder who has been blacklisted / debarred by GMSCL or any
other State/ Central Government and its Drug/Equipment /Instrument Procurement Agencies
due to failure in supply of Quality goods, shall not participate in the tender during the period
of debarring / blacklisting. If any product of company/firm/bidder were blacklisted/ debarred
at the time of bidding, for a specified period, then the same will become eligible after
blacklisting/debarring period is over. In case the period is not specified in the debarment
order, the firm shall be eligible to participate in bidding only after two years of the date of
issue of the order of blacklisting/ debarment. If any tenderer is debarred or black listed due to
failure in supply of Quality goods during the tender validity or during the validity of the rate
contract by any other State and Central Government and its Drug/Equipment /Instrument
Procurement Agencies, it is his (tenderer’s) responsibility to inform such thing to the
SMIMER Hospital, Surat Municipal Corporation.
23. Non-Disclosure of blacklisting/ debarment will invite forfeiture/recovery of EMD or SD or
Risk Purchase or disqualification for appropriate period or any other penal action at the
discretion of Surat Municipal Corporation without any further reference.
24. The right to accept, reject any or all tender (s) received is reserved by SMC and no
reason therefore will be given.
25. Tenderer will carry out demonstration / trial of each instrument/equipment at his cost only, if
required by Head of the Department. Price bid will be opened after satisfactory
demonstration / trial of each instrument/ equipment.
26. If the items quoted are approved under DGS & D, CSPO, CMSO Rate contract, the latest
copy thereof currently in force should be provided by the tenderer along with the tender.
27. If the tenderer fails to fulfill the provisions of the clauses to supply the material as stated
above within the prescribed period mentioned in the order or fails to replace or rejected
materials by those of approved quantity to the satisfaction of the authority, Surat Municipal
Corporation will be entitled to forfeit the Security Deposit.
28. Tenderer is required to quote the DETAILED SPECIFICATION of the quoted product on
separate sheet of paper along with the item number. This is IN ADDITION to the
DETAILED LITERATURE/ INFORMATION BROCHURE / DATA SHEET on the
quoted equipments, which also has to be necessarily supplied.
29. Besides submitting the specifications & literature of the quoted products, it is
MANDATORY to mention in the relevant column in the technical bid, WHETHER THE
SPECIFICATIONS OF THE QUOTED PRODUCT DIFFER FROM THE
SPECIFICATIONS MENTIONED IN THE TENDER. If they differ, the features of the
product which are absent or differing from the tender specifications should be clearly
described & justified.
If this column is not filled, it will be considered that the product is as per the tender
specifications & the tenderer will be bound to supply the equipment as per the tender
specifications & not as per the specifications quoted by himself or mentioned in the product
literature. In such case, if the product is found to be differing from the tender specifications at
the time of commissioning, then it is liable to be rejected & the tenderer will have to arrange
to transport the product back to his premises at his own cost.
30. SERVICE CENTRE : The tenderer must have and give details of a full-fledged service
centre in / near Surat with group of qualified engineers. The down time for equipment repair
shall be less than 7 (Seven) days under any circumstances with calls being attended within
hours of complaint. Incase repairs requires more than 7 days, the equipment shall have to be
kept running by arranging for backup spare parts/components.
31. INSTRUCTION MANUALS : The successful tenderer shall supply detailed operation and
servicing manuals prior to the delivery of the equipment so that the operating staff of Surat
Municipal Corporation will get familiar with the various parts and terminology of the
equipment well in time to witness installation and commissioning tests of the equipments.
32. TRAINING : Exhaustive training for operation and proper use of equipments with Do's and
Don'ts shall be given to teaching – non teaching operating staff at the time of installation of
the equipment or if required in future also. Even if it requires out-station training for few
days tenderer is bound for the same at his own cost.
33. INSTALLATION :In case it is found that equipment/accessories, spares accompanying the
equipment has been damaged during transit or found to be wrongly supplied, then it is the
responsibility of the tenderer to replace the equipment totally at his own risk and cost. No
payment under any circumstances will be certified in such cases. Thus, confirmed that the
equipments are in acceptable condition, Surat Municipal Corporation will allow the engineers
of tenderers to install the same. The Engineers of the tenderers shall get themselves satisfied
fully for the installation of the equipment. If the equipment gets damaged during
commissioning / WARRANTY period due to improper installation, it will be totally the
responsibility of the tenderer to replace the equipment at his own risk and cost. Any delay in
this case shall be liable for severe action against the tenderer.
34. COMMISSIONING : Commissioning will be considered complete only after proper
installation and submission of Manufacturer’s Product & Service Assurance Letter as per
requirement of HOD. A team consisting of doctors and technicians will witness all the
commissioning from clinical and technical point of view. The supplied representative shall
perform all the necessary tests to demonstrate and ensure the performance of the equipment
as per required standards and expectations matching with those claimed by the tenderer in
their offer. If it is observed that the equipment is not giving required performance it shall be
pointed out to the representative of the tenderer. The tenderer shall be fully responsible to
make good/remove defects from the equipment so as to demonstrate the required
performance (clinical as well as technical) to the satisfaction of the above mentioned
personnel of Surat Municipal Corporation/SMIMER. No compromise in the case shall be
tolerated by Surat Municipal Corporation/SMIMER.
35. WARRANTY CLAUSE :
(a) All the equipment(s)/instrument(s) should be warranted for 1/2 years from the date of
successful commissioning of the equipment/instrument.
(b) The warranty shall be EXHAUSTIVE for the entire equipment(s)/instrument(s) including
all attachments. PM Kit (if any) as per manufacturer guidelines, all sensors, UPS, UPS
Batteries and inbuilt printer assembly (if any) must be covered in warranty and as per
mentioned in specifications.
(c) Tenderer will have to provide free preventive maintenance services and calibration
during warranty period at a frequency of one every four months as well as unlimited
number of breakdown calls.
(d) During the warranty period if any defects are noticed in the equipment(s)/ instrument(s),
it is the sole responsibility of the tenderer to rectify the same within the specified
minimum down-time at his/her own risk and cost.
(e) If the down-time for the equipment(s)/ instrument(s) exceeds one week from the date of
intimation to the tenderer, the warranty period will be extended by equal period of time to
(f) Wherever expiry date is applicable tenderer will supply the items with longest possible
expiry date, and if required Surat Municipal Corporation will intimate the tenderer
(six) months prior to expiry date to replace the near expiry stock with the item having
longest expiry date.
(g) All accessories assembled parts & other peripherals such as printer, UPS, etc. provided
with the machine should be supplied with the standard warranty with their respective
manufacturer / supplier.
(h) Before the completion of warranty period supplier has to initiate the procedures of CMC.
36. Tenders should quote only those instruments/equipments which are readily available and in
37. The liability as to any damages and/or loss otherwise to any movable or immovable
properties, assets during loading, unloading or otherwise during the period of supply,
whether knowingly or unknowingly done or occurred shall be made good forthwith to the
SMIMER/SMC by the Awardee agency upon a communication made therefore.
38. (a) Authority letter for sales: Tender should preferably be quoted from actual manufacturer.
Tender from 1st stage dealer/2nd stage dealer/authorized distributor may also be considered
if such tender is accompanied with valid Sales Authority letter from the actual
manufacturer to the 1st stage dealer/2nd stage dealer/authorized distributor to market their
product, provided further, that such authority letter is valid at the time of bidding with the
undertaking that the required warranty cover for the product will be provided by the
(b) Authority letter for service: Equipment should preferably be serviced by the actual
manufacturer. If separate Service Agency is quoted by the tenderer, then there should be a
valid Service Authority letter from the actual manufacturer authorizing the Service
Agency to service their product, provided further, that such authority letter is valid at the
time of bidding with the undertaking that the required warranty cover for the product will be
provided by the manufacturer.
(c) Tenderer will have to submit Back-up Assurance letter from manufacturer for
availability of spare parts and service support for minimum 10 years from the date of
39. Reference letters: Reference letters from current users of the quoted models stating their
experience & specifying the model in use should be provided. Contact details of the users
should also be provided.
40. Any conditional discount given by the bidder such as discount applicable on total order
value, minimum order value on certain group of items etc. will not be considered for
evaluation purpose. However, for ordering purpose, such discount shall be considered.
41. Discount offered after price bid opening shall also not be considered for evaluation. However
in case tenderer happens to be selected bidder (without considering discount) such discount
shall be considered while placing the order.
42. In case there is a discrepancy in the claim made by the tenderer and the specifications shown
in the product literature / photograph, reliance will be placed on the specifications shown in
the product literature / photograph, ignoring the claim of the tenderer. Any change or
alteration in the product literature / photograph must be authenticated by the
manufacturer and an affidavit from the manufacturer for supplying the item as altered
or changed should also be submitted failing which such changes / alterations will be
43. Spares & CMC Rates (If applicable) : The tenderer/manufacturer should quote the amount
for comprehensive annual maintenance contract (CMC) in the price bid for next Eight years
after expiry of warranty period of two years. The party should provide minimum
preventive maintenance services per year along with unlimited number of breakdown calls
that will be provided under the maintenance contract. It should also provide the list of
services (job card) that will be carried out during its maintenance service.
If the maintenance contract is to be done by an authorized service agency an authority letter
of the manufacturer allowing and taking responsibility of the authorized agency for the CMC
must be provided. The terms & conditions for the CMC will be as under :
The authorized service agency will have to sign a letter of agreement with the SMC for
the maintenance contract.
He will have to place 5% of the contract amount with the SMC as security deposit.
Payments will be made on half yearly/quarterly basis after submission of satisfactory
service report from the H.O.D. of the concerned department.
CMC of 8 years after warranty on the entire unit with preventive maintenance kit if any.
UPS & UPS Batteries, all sensors and AC/DC adapters, all printers must be covered in
44. The undersigned reserves the right to accept "the tenders either in full or in part" or reject any
or all tender(s) received without assigning any reasons thereof.
45. ANY DISPUTE ARISING OUT OF THE CONTRACT SHALL BE SUBJECT TO SURAT
46. The specifications given in the tender represent an approximation only. Latitude to the
nearest & most suitable specification is allowed, within clinically permissible limits.
47. Any software upgradation introduced by manufacturer which is important for patient
safety, should be updated immediately in the equipment/instrument supplied by
tenderer free of cost during the warranty / CMC period.
48. Eight years CMC cost will be taken into consideration for price comparison, wherever
and as asked for.
49. After completion of warranty period, supplier will have to enter into a comprehensive
maintenance contract for 8 years. The same would include free replacement of any part /
component, if required, during the period of the contract. The maintenance contract of the
above shall be made operative from any time during the first eight years after completion of
warranty period. Any offer for service contract contrary to this condition will not be
accepted. Tenderers will also have to guarantee regular and timely supply of all the spare
parts required for the normal working of the item at a cost not exceeding the cost of such a
part charged to any other Government organization.
50. Any requirement in form of civil / electrical work / or any other such pre-requisite for
installation should be clearly mentioned along with the tender.
51. Break up of taxes has to be clearly mentioned with price quoted. If supply product/service is
exempted for GST, the bidder has to provide supporting exemption certificate of authorized
person for the same.
52. Arbitration
52.1. Arbitrator
In the event of any dispute arising between the Parties in relation to or under this Contract,
the same shall be settled by arbitration conducted by an arbitration tribunal consisting of
three arbitrators, one to be appointed by each party and the third arbitrator being appointed
by the two arbitrators so appointed. The decision of the arbitration tribunal shall be final and
52.2. Place of Arbitration
The place of arbitration shall be Surat.
The request for arbitration, the answer to the request, the terms of reference, any written
submissions, any orders and rulings shall be in English and, if oral hearings take place,
English shall be the language to be used in the hearings.
52.4. Procedure
The procedure to be followed within the arbitration, / arbitral tribunal and the rules of
evidence which are to apply shall be in accordance with the Arbitration and Conciliation Act,
1996, as amended from time to time.
52.5. Enforcement of Award
Any decision or award resulting from arbitration shall be final and binding upon the Parties.
The Parties hereto agree that the arbitral award may be enforced against the Parties to the
arbitration proceedings or their assets wherever they may be found and that a judgment upon
the arbitral award may be entered in any Court having jurisdiction thereof.
52.6. Fees and Expenses
The fees and expenses of the arbitrators and all other expenses of the arbitration shall be
initially borne and paid by respective Parties equally subject to determination by the
arbitrators. The arbitrators may provide in the arbitral award for the reimbursement to the
prevailing party of its costs and expenses in bringing or defending the arbitration claim,
including legal fees and expenses incurred by the said Party.
52.7. Performance during Arbitration
Pending the submission of and/or decision on a Dispute, difference or claim or until the
arbitral award is published; the Parties shall continue to perform all of their obligations under
this Contract without prejudice to a final adjustment in accordance with such award.
53. Compliance of Restrictions under Rule 144 (xi) of GFR 2017 as per DOE Order
(Public Procurement No.4) dated 23.02.2023 (as amended from time to time)
Restrictions on procurement from a bidder of a country which shares a land border with
I. a) Any bidder from a country which shares a land border with India will be eligible to bid
in this tender, whether of goods or services (including consultancy services and non-
consultancy services),only if the bidder is registered with the Competent Authority.
b) Further, any bidder (including an Indian bidder) who has a Specified Transfer of
Technology (ToT) arrangement with an entity from a country which shares a land border
with India will be eligible to bid in any procurement whether of goods or services
(including consultancy services and nonconsultancy services) only if the bidder is
registered with the Competent Authority.
II. The requirement of registration for bidders covered by I (b) above will be applicable for
all procurements where bids are issued / published after 01.04.2023.
III. "Bidder" (Seller / Service Provider) means any person or firm or company, including any
member of a consortium or joint venture (that is an association of several persons, or
firms or companies), every artificial juridical person not falling in any of the descriptions
of bidders stated hereinbefore, including any agency branch or office controlled by such
person, participating in a procurement process.
IV. "Bidder (or entity) from a country which shares a land border with India" for the purpose
of the Order means:
a. An entity incorporated, established, or registered in such a country; or
b. A subsidiary of an entity incorporated, established, or registered in such a country; or
c. An entity substantially controlled through entities incorporated, established, or
registered in such a country; or
d. An entity whose beneficial owner is situated in such a country; or
e. An Indian (or other) agent of such an entity; or
f. A natural person who is a citizen of such a country; or
g. A consortium or joint venture where any member of the consortiumor joint venture
falls under any of the above.
V. The beneficial owner for the purpose of (iv) above will be as under
1. In case of a company or Limited Liability Partnership, the beneficial owner is the
natural person(s), who, whether acting alone or together, or through one or more juridical
person, has a controlling ownership interest or who exercises control through other
a. "Controlling ownership interest" means ownership of or entitlement to more than
twenty-five per cent. of shares or capital or profits of the company;
b. "Control" shall include the right to appoint majority of the directors or to control the
management or policy decisions including by virtue of their shareholding or management
rights or shareholders agreements or voting agreements;
2. In case of a partnership firm, the beneficial owner is the natural person(s) who, whether
acting alone or together, or through one or more juridical person, has ownership of
entitlement to more than fifteen percent of capital or profits of the partnership;
3. In case of an unincorporated association or body of individuals, the beneficial owner is
the natural person(s), who, whether acting alone or together, or through one or more
juridical person, has ownership of or entitlement to more than fifteen percent of the
property or capital or profits of such association or body of individuals;
4. Where no natural person is identified under (1) or (2) or (3) above, the beneficial owner
is the relevant natural person who holds the position of senior managing official;
5. In case of a trust, the identification of beneficial owner(s) shall include identification of
the author of the trust, the trustee, the beneficiaries with fifteen percent or more interest
in the trust and any other natural person exercising ultimate effective control over the
trust through a chain of control or ownership.
VI. An Agent is a person employed to do any act for another, or to represent another in
dealings with third person.
VII. The registration shall be valid at the time of submission of bid and at the time of
acceptance of bid.
VIII. If the bidder was validly registered at the time of acceptance / placement of order,
registration shall not be a relevant consideration during contract execution.
IX. “Transfer of Technology” means dissemination and transfer of all forms of commercially
usable knowledge such as transfer of know-how, skills, technical expertise, designs,
processes and procedures, trade secrets, which enables the acquirer of such technology to
perform activities using the transferred technology independently.
Any false declaration and non-compliance of the above would be a ground for debarment
and further legal action in accordance with law.
Signature of Tenderer with Seal
MEDICAL SUPERINTENDENT,
SURAT MUNICIPAL INSTITUTE OF MEDICAL EDUCATION & RESEARCH,
SMIMER, OPP-BOMBAY MARKET,
UMARWADA, SURAT.
(To be signed on a Rs. 300/- stamp paper attested by notary)
I/We have carefully read all the terms and conditions & have satisfied ourselves of the
meaning implied therein and after fully understanding all the implications of these terms
and conditions. We agree with them without any reservation, and undertake to abide by it
fully and unconditionally. We understand that in the event of any declarations and
contents being false or untrue the contract is liable to be terminated & black-listed.
I/We, the undersigned, do hereby certify that all the statements made in the required
attachments are true and correct. I/We also understand that in case of wrongful / false
information, corporation is entitles to take any civil & criminal punitive action against me
The undersigned also hereby certifies that neither our firm M/s
____________________________________ nor any of its constituent partners have
abandoned any work in India nor any contract awarded to us has been rescinded during
last five years, prior to the date of this bid.
The undersigned hereby authorize(s) and request(s) any bank, person, authorities,
government or public limited institutions, firm or corporation to furnish pertinent
information deemed necessary and requested by the SMC to verify our statements or our
competence and general reputation etc.
The undersigned understands and agrees that further qualifying information may be
requested, and agrees to furnish any such information at the request of the SMC.
The SMC and its authorized representatives are hereby authorized to conduct any
inquiries or investigations to verify the statements, documents, and information submitted
in connection with this bid and to seek clarification from our bankers and clients
regarding any financial and technical aspects. This Affidavit will also serve as
authorization to any individual or authorized representative to any institution referred to
in the supporting information, to provide such information deemed necessary and
requested by representative of Surat Municipal Corporation to verify statements and
information provided in the Tender or with regard to the resources, experience and
competence of the Applicant.
Signed by the Authorize signatory of the firm
Title of the office
Name of the firm
Note:- The affidavit format as indicated above to be furnished on non-judicial stamp paper of
Rs.300/- and duly notarized.
HIGHER PRICE / LOWER PRICE CERTIFICATE
certify that the prices quoted by us in Tender Enquiry # TENDER NOTICE NO:
SMIMER/HOSPITAL/MEDICAL SUPERINTENDENT/10/2026-27 are not higher
than the prices: Charged by us to wholesalers or for institutional supplies;
2. I/We further certify that I/We have not supplied or quoted for any item in Tender Enquiry
# TENDER NOTICE NO: SMIMER/HOSPITAL/MEDICAL
SUPERINTENDENT/10/2026-27 at prices lower than those quoted for the relevant
items to any Government / Semi Government / Public / Charitable Trust Organization /
Institution within the period of 180 days preceding the last date of submission of the
SIGNATURE & STAMP OF
AUTHORITY LETTER FOR SALES
(On Manufacturer’s Letterhead)
The Medical Superintendent,
SMIMER Hospital,
Subject: Authority letter for sales
Reference : Tender Notice No.SMIMER/Hospital/Medical Superintendent/10/2026-27
authorized distributor/dealer for Gujarat in India. They are authorized to sale, market
& distribute our products in regards to this Tender Notice
No.SMIMER/Hospital/Medical Superintendent/10/2026-27.
{SIGNATURE & STAMP OF THE AUTHORIZED SIGNATORY OF MANUFACTURER}
AUTHORITY LETTER FOR AFTER SALES SERVICE
(On Manufacturer’s Letterhead)
The Medical Superintendent,
SMIMER Hospital,
Subject: Authority letter for after sales & Service
Reference : Tender Notice No.SMIMER/Hospital/Medical Superintendent/10/2026-27
We hereby state that the preventive & breakdown services during warranty and
post warranty will be carried out by us or our sole authorized service provider whose
details are as follows. We further undertake to provide full support to the said authorized
service provider and in case of failure of the latter, to provide the required service support
Name Address of Email Contact No. Name &
Service Centre Qualification of
Service Engineer
{SIGNATURE & STAMP OF THE AUTHORIZED SIGNATORY OF MANUFACTURER}
MANUFACTURER’S PRODUCT & SERVICE ASSURANCE LETTER
(as per tender terms no.38(b))
(On Manufacturer’s Letterhead)
The Medical Superintendent,
SMIMER Hospital,
Subject: Back-up assurance letter for product & service assurance
hereby certify that in reference to tender enquiry # TENDER NOTICE NO:
SMIMER/HOSPITAL/MEDICAL SUPERINTENDENT/10/2026-27, I/We hereby will
provide our product, spares and service for minimum ten (10) years from the date of
installation, either directly or through our authorized parties, as per the tender terms &
conditions and will inform the customer immediately if there is any change of our
authorized dealer/service provider/service person. Moreover in case of failure of the
service provider, we undertake to provide the required service support ourselves.
{SIGNATURE & STAMP OF THE AUTHORIZED SIGNATORY OF MANUFACTURER}
TENDER FORMAT (GENERAL)
"TENDER FOR SUPPLYING & INSTALLING EQUIPMENTS / INSTRUMENTS FOR
PHYSIOTHERAPY DEPARTMENT OF SMIMER HOSPITAL"
1 (a) Name of the Tenderer :
(b) Party Code as awarded by SMC :
(c) Are you a Manufacturer/ :
Authorized Dealer/ Sub Dealer/
Any Other (Please specify)
(d) Income Tax No. (PAN) : No. :
(e) GST : No. :
(f) Professional Tax No. : No. :
(g) Details of Other Licenses held : Yes / No. :
Registration Details/ Validity Date
[Submit attested copy of certificates]
(h) What is the firm of Business :
You submit this tender at
-Sole Proprietor ?
(Registration No. under shops &
Establishment Act.)
-Sole Proprietor ? :
(Registration No. under shops &
Establishment Act.)
-Hindu Undivided Family (HUF)? :
-Partnership Firm ? :
-Public Limited Company under :
the Companies Act ?
-Private Limited Company under :
the Companies Act ?
-State Govt. owned Undertaking :
Corporation/ Enterprise?
-Central Govt. owned :
Undertaking Corporation/
-Co-Operative Society? :
-Unit known as “Khadi & Village :
Industries” as per Khadi and
Village Industries Commission
-Association of Persons ? :
-Any Other, Please Specify. :
2 Complete Address of the Tenderer :
(a) Head Office :
(b) Main Office in Gujarat :
(c) Office Nearest to Surat :
(d) Phone No. : :
Name of Contact Person
3 Give details about your mode of :
ensuring supply to SMC.
4 If you are a dealer, kindly state the :
name of your principals for each
item. (Submit a copy authenticated
by the Principal)
5 If you are a manufacturer, kindly :
provide the manufacturing
facilities that you have, giving
details of the quality control set-up
that you may have ( The details
may be given as an annexure.)
6 Fully fledged Service Center :
nearest to Surat (For each
manufacturing company, if dealer)
Name and address of local
engineer including contact no.
7 Is any sales promotion scheme(s) : [ ] Yes
launched by you? ( Pl. Tick Mark) [ ] No.
If yes, mention detail thereof.
8 Do you agree to all the terms and : [ ] Yes
conditions of the Tender? [ ] No.
If no, then please specify where
and how you differ.
9 EMD Details :
(a) Bank Name & Address :
(b) Pay Order / Draft No. :
Pay Order Amount . :
Date: Signature and Seal of
Authorized Person
Tenderer's Seal : _______________________
Schedule of documents attached
Sr. Documents Mandatory / Attached Your
No. Preferable Yes/No/Not Page
1 Copy of PAN Card Mandatory
2 Copy of GST Registration Mandatory
3 Copy of Registration of Firm Mandatory
4 Affidavit on non judicial stamp paper of Rs.300/-. Mandatory
6 Details of Tender Fee, Earnest Money Deposit - Mandatory
Amount, Banker's Cheque / DD / Pay Order Number,
6 Higher price / lower price certificate (Annexure-II) Mandatory
7 Copy of Authority letter for after sales service Mandatory
8 Manufacturer’s Product & Service Assurance Letter Mandatory
9 Certified / notarized copy of valid Small Scale Industry Mandatory if
Registration, if applicable. applicable
10 Certified / notarized copy of Certificate from Practicing Mandatory if
Chartered Accountant or Practicing company Secretary applicable
that the unit / bidder still continues to be Small Scale,
Tiny/ Cottage Industry as on last date of submission of
bid if applicable..
9 Manufacturing License / Product Permission / Mandatory if
Registration Certificate with C.S.P.O. applicable
10 Partnership deed / Memorandum of Articles / Mandatory if
Registration of firm etc, if applicable. applicable
11 Copy of Profession Tax if applicable. Mandatory if
12 Bank solvency certificate of nationalized/scheduled bank Mandatory
(20% of the quoted amount of tender) for current any one (out
financial year / Turn over certificate of CA for last three of three)
financial years / Copy of Income Tax Returns of last
three financial years (Out of three - anyone)
13 Copy of Authority letter for sales (Annexure-III) if not Mandatory if
OEM (Original Equipment Manufacturer) applicable
14 Copy of Quality Certificate with validity period like Mandatory as
ISO/CE/US FDA etc. per tender
15 Details of Nearest Authorized Service Centre Mandatory
Note : It is verified that all the certificates / permissions / documents are valid and current as
on date and have not been withdrawn / cancelled by the issuing authority.
(i) Additional documents other than above if any, required for supporting the claims made
by the bidder should be attached.
(ii) Demand draft for E.M.D. & Tender (Bid) fee shall be submitted in electronic format through
online mode (by scanning) while uploading the bid. This submission shall mean that E.M.D.
& tender fee are received for purpose of opening of the bid. Accordingly offer / tenders of
those tenderers whose E.M.D. & tender fee is received electronically shall be opened.
However, for the purpose of realization of E.M.D. & Tender Fee bidder shall send the
E.M.D. as well as Tender Fee in required format in original through RPAD/Speed post so as
to reach to Chief Accountant, Account department (main office) SMC within 7 days from
the last date of online submission of the price bid. Punitive action shall be initiated for non
submission of E.M.D. & Tender Fee in original to Account department (main office) by
bidder as follows :
In the first case of non-receipt of the original demand draft in the office of the Chief
Accountant of Surat Municipal Corporation within the stipulated time, penal action will
be taken to recover the penalty as per the table given below.
No. Tender Amount Penalty Amount Rs.
1 Up to Rs. 1.00 crore 10,000/-
2 more than Rs. 1.00 crore and Up to Rs. 10.00 crore 20,000/-
3 More than Rs. 10.00 crore and up to Rs. 50,000 crore 30,000/-
4 More than Rs. 50.00 crore and up to Rs. 100.00 crore 70,000/-
5 More than Rs. 100.00 crore 1,00,000/-
If the tenderer does not deposit the above penalty amount with the Municipal Corporation
If the tenderer commits such a default/mistake for the second time,
In both the cases punitive action (if the contractor does not pay the tender fee and the security
deposit within the stipulated time, the registration of the contractor will be kept in abeyance
for 06 (six) months and the e-tendering code will be cancelled for 06 (six) months.) will be
taken against the contractor
EMD, Tender fee and affidavit should be submitted in hard copy alongwith technical bid.
E.M.D. & Tender fee & affidavit on non-judicial stamp paper of Rs.300.00 shall be submitted
online in electronic format also (by scanning) while uploading the bid. Scanned documents
must be coloured scans to be seen as original. Scanning in black & white or grey shall not
Affidavit must be notarized clearly displaying stamp, number and name of the notary and all
other documents should be duly signed & stamped by the tenderer.
No documents will be accepted before or after opening of technical bid.
Company/Firm name with seal_____________
PHYSIOTHERAPY DEPARTMENT - SMIMER HOSPITAL
ITEMWISE DETAILED SPECIFICATIONS :
Item No.1 : COMBINATION THERAPY UNIT – ELECTROTHERAPY & ULTRASOUND
Manufacturer Name : Brand Name : Model Name :
Required Specifications : Specifications available in offered model compared to column (A)
(1) General Requirements :
The offered Combination Therapy Unit shall be a microprocessor-controlled physiotherapy system
integrating electrotherapy and therapeutic ultrasound in a single unit. The system shall be suitable
for individual, simultaneous, and combined treatment applications.
The unit shall comply with the following minimum requirements:
The system shall support both low-frequency and medium-frequency electrotherapy
The system shall provide electrotherapy and ultrasound therapy for individual,
simultaneous, and combination treatment.
The system shall be capable of treating up to three patients simultaneously, as applicable to
the selected therapy configuration.
The system shall have minimum four independent electrotherapy channels.
Independent intensity adjustment shall be available for each electrotherapy channel.
The system shall provide therapeutic ultrasound at 1 MHz and 3 MHz.
The system shall include condition-wise pre-programmed treatment protocols, with a
minimum of 132 programs.
The system shall provide user-programmable memory with facility to store patient name
and treatment settings.
The system shall have cable and electrode checking facility.
The system shall incorporate an advanced patient safety system.
Ultrasound contact monitoring shall be provided through an acoustic/contact sensor.
The unit shall be compact, lightweight and suitable for clinical use.
The unit shall have an easy-to-operate user interface.
Intensity adjustment shall be provided through an encoder/control knob.
The unit shall be supplied with suitable ultrasound transducers, including large and small
size transducers, as specified.
Provision for a static ultrasound transducer shall be available.
(2) User Interface and Display
Parameter Minimum Requirement
Display 7-inch Colour Resistive Touch Display or more
User Interface Touch-screen based, user-friendly interface
Intensity Control Encoder-based control
Treatment Selection Manual and pre-programmed selection
Patient Memory User-settable memory with patient name
Technical Data Treatment parameters shall be displayed on screen
Minimum 120 condition-wise pre-programmed
3. Electrotherapy Channels
Parameter Minimum Requirement
Electrotherapy Channels 4 channels
Channel Control Independent intensity adjustment for each channel
Simultaneous Treatment Up to 3 patients
Therapy Selection Individual / simultaneous / combined operation
Safety Monitoring Cable and electrode checking facility
4. Interferential Therapy (IFT)
The unit shall provide Interferential Therapy with the following minimum specifications:
Parameter Specification
Carrier Frequency 2,000–4,000 Hz, adjustable in 100 Hz steps
Carrier Frequency 4,000–10,000 Hz, adjustable in 500 Hz steps
Base Frequency 1–250 Hz, adjustable in 1 Hz steps
Sweep Frequency 0–250 Hz, adjustable in 1 Hz steps
Sweep Modulation Programs 1/1 sec, 5/5 sec, 6/6 sec
Therapy Modes Four Pole Classic
Four Pole Vector 90°
Four Pole Vector 45°
Two Pole Pre-modulated
5. Russian Current
Parameter Specification
Carrier Frequency 2,000–4,000 Hz, adjustable in 100 Hz steps
Carrier Frequency 4,000–10,000 Hz, adjustable in 500 Hz steps
Modulation Constant / Surge
Ramp Rise/Fall 1–10 sec, adjustable in 1 sec steps
Burst Frequency 30–250 Hz, adjustable in 1 Hz steps
Hold ON Time 1–99 sec, adjustable in 1 sec steps
Hold OFF Time 1–99 sec, adjustable in 1 sec steps
The system shall provide TENS therapy with the following minimum specifications:
Parameter Specification
Frequency 2–250 Hz
Pulse Width 20–250 μsec
Pulse Width Adjustment 1 μsec
Burst Frequency 1–10 Hz
Sweep Frequency 2–245 Hz to 7–250 Hz
Waveforms Symmetric / Asymmetric
Operating Modes Continuous
7. Diadynamic Currents
The unit shall provide the following Diadynamic current types:
Parameter Specification
Current Types DF
8. VMS – Vibratory Motor Stimulation
Parameter Specification
Frequency 2–250 Hz
Waveform Inverted Symmetric
Pulse Width 20–250 μsec
9. Muscle Stimulator Currents
9.1 Galvanic Currents
Parameter Specification
Plain Galvanic Continuous DC current
Interrupted Galvanic Available
Diagnostic Pulse Duration
Therapeutic Pulse Duration 30–300 msec
Adjustment Step 10 msec
9.2 Faradic / Surge Faradic
Parameter Specification
Frequency 50 Hz
Pulse Width 0.7 msec
Surge ON Time 1–10 sec, 1 sec step
Surge OFF Time 1–6 sec, 1 sec step
Parameter Specification
Frequency 142.8 Hz
OFF Time 5 msec
10. HV Pulse Current
Parameter Specification
Frequency 1–200 Hz, adjustable in 1 Hz steps
Pulse Width 100 μsec
Output Type Constant / Surge
11. Microcurrent
Parameter Specification
Frequency 1–1,000 Hz
Intensity 10–1,000 μA
12. Iontophoresis
Parameter Specification
Dosage 2–150 mA/min
Dosage Adjustment 2 mA/min step
Intensity 1–5 mA
Intensity Adjustment 0.5 mA step
Output Type Constant / Interrupted
13. Therapeutic Ultrasound
The unit shall incorporate therapeutic ultrasound suitable for physiotherapy applications.
Parameter Minimum Requirement
Ultrasound Frequency 1 MHz and 3 MHz
Operating Modes Continuous / Pulsed
Pulse Frequency 16 Hz / 48 Hz / 100 Hz
Pulse Settings 9 settings
Maximum Intensity 3 W/cm²
Beam Type Collimated
Beam Non-Uniformity Ratio (BNR) Maximum 5:1
Contact Control Acoustic Sensor
14. Ultrasound Transducers
The unit shall be supplied with suitable ultrasound transducers as specified below:
Effective Radiating Area
Transducer Requirement
Large Ultrasound Transducer 5 cm² Standard
Small Ultrasound Transducer 1 cm² Optional
Provision shall be
Static Ultrasound Transducer 5 cm²
15. Combination Therapy Operation
The system shall provide integrated operation of electrotherapy and ultrasound therapy.
Requirement Specification
Electrotherapy Shall be available independently
Ultrasound Therapy Shall be available independently
Combination Therapy Electrotherapy + Ultrasound
Simultaneous Operation Shall be supported
Channel Intensity Control Independent for each channel
Treatment Configuration User selectable
The system shall allow the operator to select appropriate electrotherapy parameters and ultrasound
parameters according to the prescribed treatment protocol.
16. Pre-Programmed and User-Defined Programs
The unit shall have a minimum of 120 condition-wise pre-programmed treatment protocols.
Treatment protocols shall be selectable according to the clinical condition.
The system shall permit modification of treatment parameters where applicable.
The unit shall provide user-settable memory for storing customized treatment settings.
Patient name shall be capable of being associated with stored treatment settings.
Stored settings shall be accessible through the user interface.
17. Patient Safety and Monitoring
The system shall incorporate appropriate safety features, including:
Advanced patient safety monitoring system.
Cable checking facility.
Electrode checking facility.
Ultrasound contact/acoustic sensor for monitoring appropriate coupling/contact.
Independent intensity control for individual channels.
Controlled intensity adjustment to minimize unintended output.
Appropriate output indication on the display.
Safety provisions in accordance with applicable medical electrical equipment standards.
18. Physical and Construction Requirements
Parameter Minimum Requirement
Construction Compact clinical design
Cabinet Plastic cabinet or anything better
Dimensions (L × B × H) 30 × 26 × 15 cm approximate
Weight 3.2 kg approximate
Design Lightweight and compact
Operation Easy to operate
Display 7-inch Colour Resistive Touch Display or more
19. Electrical and Safety Specifications
Parameter Specification
Mains Voltage 240 V AC ± 10 V AC,with Indian 3 pin top
Mains Frequency 50 Hz
Safety Class Class I
Applied Part Type BF
Safety Standard IEC 60601-1
Shall comply with applicable international standards
International Compliance
and specifications
20. Minimum Scope of Supply
The offered system shall be supplied as a complete, ready-to-use combination therapy system,
Main combination therapy unit.
Electrotherapy cables and required accessories.
Suitable electrodes and electrode accessories.
Large ultrasound transducer, 5 cm² ERA.
Small ultrasound transducer, 1 cm² ERA, where specified.
Static ultrasound transducer, 5 cm² ERA, where specified.
Mains power cable and necessary standard accessories.
User/operation manual.
Any other standard accessories required for safe and functional operation of the system.
21. ACCESSORIES AND FITTINGS
1. All standard accessories required for normal operation of the equipment shall be supplied
along with the unit.
2. The quoted price shall include all accessories required for combination therapy system..
3. Any accessory essential for normal functioning of the quoted equipment shall not be
supplied as an optional item and shall be included in the basic quoted price.
4. The bidder shall provide a complete list of accessories supplied with the quoted model.
5. Any accessory essential for normal functioning of the quoted equipment shall not be
supplied as an optional item and shall be included in the basic quoted price.
22 . SAFETY FEATURES
1. The equipment shall have appropriate safety features for safe clinical operation..
2. Appropriate fault/error indication shall be provided wherever applicable.
3. The equipment shall prevent unintended operation as far as practicable.
23 . INSTALLATION AND COMMISSIONING
1. The successful bidder shall supply, install and commission the complete equipment at the
consignee's premises.
2. Installation and commissioning shall be carried out by the manufacturer's
authorized/service-trained personnel.
3. The supplier shall demonstrate all functions of the equipment after installation.
4. The supplier shall demonstrate all modes as specified in the tender.
5. Basic operational training shall be provided to the concerned hospital/physiotherapy staff
without additional cost.
1. The complete equipment shall be covered under a comprehensive warranty for a period of
2 (two) years from the date of successful installation, commissioning and acceptance.
2. The warranty shall cover the complete unit without any exclusion.
3. The comprehensive warranty shall include, but not be limited to:
4. Main unit, Motor, Mechanical components, Electrical/electronic components ,Display,
Control panel, Internal wiring, , Standard accessories supplied with the unit, Labour, Service
charges and Replacement of defective components.
5. There shall be no exclusion of any component forming part of the supplied equipment
during the warranty period.
6. The warranty shall include breakdown service and preventive maintenance.
25. COMPREHENSIVE MAINTENANCE CONTRACT (CMC)
1. After completion of the 2-year warranty period, the complete equipment shall be covered
under Comprehensive Maintenance Contract (CMC) for 8 (eight) years.
2. The CMC shall cover the complete units as specified above without any exclusion.
3. The total period of warranty and CMC support shall therefore be 10 years from the date of
successful installation/commissioning/acceptance.
4. The CMC shall include:Preventive maintenance, Breakdown maintenance, Labour/service
charges, Replacement of defective components, Mechanical components,
Electrical/electronic components, Motor, Display and control system, Internal wiring,
Standard accessories supplied with the equipment.
5. There shall be no exclusion of any component of the complete unit under CMC..
26. PREVENTIVE MAINTENANCE SERVICE (PMS)
1. During the 2-year warranty period, a minimum of 2 PMS visits per year shall be provided.
2. Thus, a minimum of 4 PMS visits shall be provided during the complete warranty period.
3. During the 8-year CMC period, a minimum of 3 PMS visits per year shall be provided.
4. Thus, a minimum of 24 PMS visits shall be provided during the complete CMC period.
6. A service/PMS report shall be submitted after every preventive maintenance visit and
acknowledged by the concerned hospital representative.
27. BREAKDOWN SERVICE AND RESPONSE TIME
1. The service complaint shall be attended/responded to within 24 hours from the time of
complaint registration.
2. The breakdown shall be resolved within 48 hours from the time of complaint registration,
wherever technically feasible.
28. SERVICE CENTRE REQUIREMENT
1. The bidder/manufacturer or its authorized dealer/service provider shall have an established
and functional service centre in Gujarat or in a location reasonably accessible to Surat.
2. The service centre shall be capable of providing preventive and breakdown maintenance for
the quoted model.
3. The bidder shall submit the organization chart of service engineers and their contact details.
29. Certificates :-
The quoted model should be USFDA or European CE or CDSCO certified product only.
Item No.2 : Class IV High Power Laser
Manufacturer Name : Brand Name : Model Name :
Required Specifications : Specifications available in offered model compared to column (A)
1. General Requirements
The offered system shall be a Class IV High Power Laser Therapy System intended for non-invasive
pain management, therapeutic treatment, and biostimulation applications.
The system shall incorporate a dual-wavelength fiber laser source and shall provide single-
wavelength as well as dual-wavelength operation.
2. Laser System Specifications
Parameter Minimum Technical Requirement
Laser Classification Class IV High Power Laser
Laser Technology High-power fiber laser
Wavelengths 980 nm and 1064 nm
Output Power at 980 nm 30 W
Output Power at 1064 nm 15 W
Total Rated Output Power 45 W
Wavelength Operation Single-wavelength and dual-wavelength operation
Operating Modes Continuous and Pulsed
Pulse Frequency 0.2 Hz to 20 kHz
Pulse Width 10 μs to 3 seconds
Control Accuracy/Resolution ≤ 50 ns, as applicable to the pulse-control parameter
Laser Source Fiber laser
3. User Interface and Control
The system shall have:
1. A 12-inch or larger touch screen display for operation and parameter selection.
2. Precise control of treatment parameters.
3. Preset clinical treatment protocols.
4. Recommended treatment parameters for preset protocols.
5. User-selectable treatment parameters.
6. Provision for customization and storage of treatment protocols.
7. Professional treatment guidance through preset treatment parameters.
8. Selection of single or dual wavelength operation, as applicable.
9. Selection of continuous or pulsed operating modes.
4. Treatment Applicators / Working Heads
The system shall be supplied with minimum four (4) treatment applicators/working heads,
Small laser beam.
Suitable for treatment of small anatomical areas such as fingers and wrist.
Medium laser beam.
Suitable for anatomical areas such as elbow, ankle, foot and neck.
Large laser beam.
Suitable for anatomical areas such as shoulder, lower back, thigh and calf.
Glass Ball Applicator
Designed for direct skin contact.
Shall permit smooth movement over the treatment area.
Suitable for uniform application of laser therapy over the treatment area.
5. Therapy Programs and Protocols
The system shall provide:
Minimum nine (9) body-part-specific preset treatment protocols.
Recommended treatment parameters for preset protocols.
Preset clinical treatment protocols.
Customizable treatment settings.
Provision for user-defined treatment protocols.
Professional treatment guidance through the preset treatment programs.
6. Clinical Applications
The system shall be suitable for therapeutic application in pain management and related
musculoskeletal conditions, including but not limited to:
Cervical Spondylosis
Frozen Shoulder
Osteoarthritis
Wrist Arthritis
Foot Arthritis
Myofascial Pain Syndrome
Muscle Injuries
Muscle Contusions
General Pain Management
7. Safety Features
The system shall incorporate the following safety features:
Emergency Safety Button
Safety Filter Cup
Integrated cooling fan system
Appropriate laser safety provisions for Class IV laser operation
8. Physical / Technical Data
Parameter Specification
Display 12-inch Touchscreen
Laser Source Fiber Laser
Number of Treatment Applicators Minimum
Preset Treatment Protocols Minimum
Package Dimensions Approximately 62 × 58 × 43 cm
Gross Weight Approximately 30 kg
9. Functional Requirements
The offered equipment shall:
Be a Class IV High Power Laser Therapy System.
Provide 980 nm and 1064 nm wavelengths.
Provide 30 W output at 980 nm and 15 W output at 1064 nm.
Support continuous and pulsed operating modes.
Provide single- and dual-wavelength operation.
Provide deep-tissue laser therapy capability.
Include minimum four treatment applicators/working heads.
Include minimum nine preset body-part-specific treatment protocols.
Provide customizable treatment parameters/protocols.
Include a touchscreen user interface of minimum 12.1 inches.
Include an emergency safety button and laser safety provisions.
Be supplied complete with all standard accessories required for normal operation.
10. Compliance Documentation
The bidder shall provide, along with the technical bid:
Manufacturer's technical datasheet/brochure.
Detailed technical specifications of the offered model.
Product catalogue, where applicable.
Details of supplied treatment applicators/accessories.
User/operation manual.
Training details for the operating personnel.
11. General terms and conditions:-
Warranty: 2 years comprehensive warranty followed by 8 years CMC.
Warranty & CMC Coverage: Warranty and CMC shall cover the complete unit without any
exclusion. All electrical, electronic and mechanical parts, all motor, sensors, power cable , AC to DC
adapter, LASER unit, all cables, displays. keypads.
PMS: 2 Preventive Maintenance Services (PMS) per year during the warranty period and 2 PMS
per year during the CMC period.
Breakdown Calls: CMC shall include unlimited breakdown calls without any additional charges.
Service Support: The service provider shall have trained service engineers preferably based in
Surat or nearby Surat, with a service centre in Gujarat or nearby Gujarat for prompt support.
Breakdown Response: Breakdown calls shall be attended within 24 hours and the issue shall be
resolved within 48 hours.
Certification: The unit shall be CDSCO/BIS/CE/USFDA certified, as applicable, and shall comply
with the latest applicable electrical safety standards.
Product Demonstration: On-site demonstration of the quoted product at SMIMER Hospital, Surat
shall be mandatory.
Item No.3 : Decompression Therapy Unit with Table
Manufacturer Name : Brand Name : Model Name :
Required Specifications : Specifications available in offered model compared to column (A)
A. GENERAL TECHNICAL REQUIREMENTS
1. The equipment shall be a Cervical and Lumbar Traction Unit suitable for
hospital/physiotherapy clinical use.
2. The equipment shall be new, unused and of current production.
3. The unit shall be suitable for regular and continuous clinical use.
4. The equipment shall provide Static, Intermittent and Cyclic traction modes.
5. The equipment shall have provision for both:
o Cervical traction.
o Lumbar traction.
6. The unit shall provide progressive traction and step-increment facility.
7. The unit shall provide variable/selectable traction speed.
8. The equipment shall have a high traction force range of up to 90 kg.
9. The equipment shall have a base/low force range of up to 85 kg.
10. The equipment shall operate on a wide input voltage range of 100–240 V AC.
11. The user shall be able to define:
Hold time, Rest time and Treatment time.
12. The equipment shall have a Graphic LCD display or equivalent digital display for displaying
all relevant treatment parameters.
13. The equipment shall have a user-friendly digital interface for setting and monitoring
treatment parameters.
14. The equipment shall have provision for Saunders fitting or equivalent standard traction
15. The traction mechanism shall be provided with a reliable, durable and heavy-duty motor.
16. The unit shall provide low-noise/noiseless operation during normal operation.
17. The equipment shall be compact and suitable for easy mounting on a treatment table.
18. The equipment shall be lightweight and convenient to handle.
B. TECHNICAL SPECIFICATIONS OF TRACTION UNIT
1. Traction Force: 3 kg to 90 kg.
2. Traction Force Increment: 1 kg step.
3. Base Force: 2 kg to 85 kg.
4. Base Force Increment: 1 kg step.
5. Traction Mode: Cervical and Lumbar.
6. Traction Type/Mode: Static, Intermittent and Cyclic.
7. Treatment Time: 01 to 99 minutes.
8. Treatment Time Increment: 1 minute.
9. Hold Time: 01 to 99 seconds.
10. Hold Time Increment: 1 second.
11. Rest Time: 01 to 99 seconds.
12. Rest Time Increment: 1 second.
13. Traction Speed: Minimum 5 selectable speed levels.
14. Progressive Step: 1 to 10 steps maximum.
15. The equipment shall permit appropriate setting of traction force, base force, hold time, rest
time, treatment time and speed according to the selected treatment mode.
C. DISPLAY AND USER INTERFACE
1. The equipment shall have a Graphic LCD display or equivalent display.
2. The display shall clearly indicate relevant treatment parameters.
3. The display shall, as applicable, show:
4. Traction mode, Cervical/Lumbar mode., Traction force, Base force, Hold time, Rest time,
Treatment time, Traction speed ,Progressive step, Treatment status and Error/safety
5. The control panel shall be digital and user-friendly.
6. The parameters shall be easy to set and monitor during treatment.
D. MOTOR AND MECHANICAL REQUIREMENTS
1. The unit shall be provided with a reliable and durable heavy-duty motor.
2. The motor and traction mechanism shall be suitable for regular hospital/clinical use.
3. The traction force shall be applied and released smoothly.
4. The equipment shall operate with minimum operational noise.
5. The equipment shall have durable construction suitable for long-term clinical use.
6. The equipment shall be designed for easy mounting/placement on a suitable treatment
7. The unit shall be compact and lightweight for convenient handling.
E. ELECTRICAL SPECIFICATIONS
1. Input Voltage: 240 V AC ± 10 V AC
2. Frequency: 50 Hz.
3. Power Consumption: 50 Watts approximate.
4. The equipment shall be supplied with suitable power cable, plug and necessary electrical
5. The equipment shall comply with applicable electrical and medical equipment safety
F. Approximate DIMENSIONS AND WEIGHT
1. Length: 285 mm.
2. Breadth: 198 mm.
3. Width: 324 mm.
4. Weight: 9.5 kg.
5. Minor variation in dimensions and weight may be acceptable provided the equipment
meets all specified functional and performance requirements.
G. Technical Specifications – Decompression Treatment Table
1. Features and Treatment Options
Saunders cervical traction system.
Supine, prone, and side-lying decompression (antalgic positioning).
Carpal/wrist traction device.
Hip/ankle traction device.
Multipurpose treatment and manipulation table.
Treatment options for back, neck, hip, knee, carpal, and wrist traction/decompression.
Patient stabilization system with axilla posts.
Manually adjustable pelvic tilt section from 0° to 20°.
Repositionable headpiece.
Adjustable armrests.
Designed to support decompression treatment for patients with disc-related conditions.
2. Technical Specifications
Parameter Specification
Mains power supply 240 V AC ± 10 V AC, 50 Hz with Indian 3 pin top
Total length (table + traction arm) 252 cm
Head angle inclination −20° to +40°
Armrest angle inclination −20° to +40°
Pelvic angle inclination 0° to +20°
Leg angle inclination 0° to +45°
Leg section displacement 13 cm
Minimum table height 59 cm
Maximum table height 108 cm
Dynamic lifting capacity Less than 201 kg
Maximum working load Less than 276 kg
Table weight Approx 165 kg
H. ACCESSORIES AND FITTINGS
1. All standard accessories required for normal operation of the equipment shall be supplied
along with the unit.
2. The quoted price shall include all accessories required for Cervical and Lumbar traction.
3. The equipment shall have provision for Saunders fitting or equivalent standard fitting.
4. Any accessory essential for normal functioning of the quoted equipment shall not be
supplied as an optional item and shall be included in the basic quoted price.
5. The bidder shall provide a complete list of accessories supplied with the quoted model.
I. SAFETY FEATURES
6. The equipment shall have appropriate safety features for safe clinical operation.
7. The equipment shall have provision for emergency/manual release of traction.
8. The equipment shall have protection against excessive/unintended traction force.
9. The equipment shall provide safe release/termination of traction upon completion of
10. Appropriate fault/error indication shall be provided wherever applicable.
11. The equipment shall prevent unintended operation as far as practicable.
J. INSTALLATION AND COMMISSIONING
1. The successful bidder shall supply, install and commission the complete equipment at the
consignee's premises.
2. Installation and commissioning shall be carried out by the manufacturer's
authorized/service-trained personnel.
3. The supplier shall demonstrate all functions of the equipment after installation.
4. The supplier shall demonstrate all modes as specified in the tender.
5. Basic operational training shall be provided to the concerned hospital/physiotherapy staff
without additional cost.
1. The complete equipment shall be covered under a comprehensive warranty for a period of
2 (two) years from the date of successful installation, commissioning and acceptance.
2. The warranty shall cover the complete unit without any exclusion.
3. The comprehensive warranty shall include, but not be limited to:
4. Main unit, Motor, Mechanical components, Electrical/electronic components ,Display,
Control panel, Internal wiring, Traction mechanism, Standard accessories supplied with the
unit, Labour, Service charges and Replacement of defective components.
5. There shall be no exclusion of any component forming part of the supplied equipment
during the warranty period.
6. The warranty shall include breakdown service and preventive maintenance.
L. COMPREHENSIVE MAINTENANCE CONTRACT (CMC)
1. After completion of the 2-year warranty period, the complete equipment shall be covered
under Comprehensive Maintenance Contract (CMC) for 8 (eight) years.
2. The CMC shall cover the complete unit without any exclusion.
3. The total period of warranty and CMC support shall therefore be 10 years from the date of
successful installation/commissioning/acceptance.
4. The CMC shall include:Preventive maintenance, Breakdown maintenance, Labour/service
charges, Replacement of defective components, Mechanical components,
Electrical/electronic components, Motor, Display and control system, Traction mechanism,
Internal wiring, Standard accessories supplied with the equipment.
6. There shall be no exclusion of any component of the complete unit under CMC.
M. PREVENTIVE MAINTENANCE SERVICE (PMS)
1. During the 2-year warranty period, a minimum of 2 PMS visits per year shall be provided.
2. Thus, a minimum of 4 PMS visits shall be provided during the complete warranty period.
3. During the 8-year CMC period, a minimum of 3 PMS visits per year shall be provided.
4. Thus, a minimum of 24 PMS visits shall be provided during the complete CMC period.
7. A service/PMS report shall be submitted after every preventive maintenance visit and
acknowledged by the concerned hospital representative.
N. BREAKDOWN SERVICE AND RESPONSE TIME
1. The service complaint shall be attended/responded to within 24 hours from the time of
complaint registration.
2. The breakdown shall be resolved within 48 hours from the time of complaint registration,
wherever technically feasible.
O. SERVICE CENTRE REQUIREMENT
1. The bidder/manufacturer or its authorized dealer/service provider shall have an established
and functional service centre in Gujarat or in a location reasonably accessible to Surat.
2. The service centre shall be capable of providing preventive and breakdown maintenance for
the quoted model.
3. The bidder shall submit the organization chart of service engineers and their contact details.
P. CERTIFICATES:-
1. The quoted model should be USFDA or European CE or CDSCO certified product only.
Item No.4 : Wall mount Resistive Exercise Unit Setup
Manufacturer Name : Brand Name : Model Name :
Required Specifications : Specifications available in offered model compared to column (A)
1. Product Description
The TheraBand Wall Station shall be a compact, total-body rehabilitation and strength-training
system designed for in-clinic use. The system shall support progressive resistance exercises for both
upper and lower extremities and enable patients to practice movement patterns that can be
continued using the TheraBand resistance system at home.
2. Functional Requirements
The wall station shall provide a multi-dimensional exercise platform with three planes of
The system shall support rehabilitation and strengthening exercises for upper and lower
The system shall be suitable for in-clinic rehabilitation, physical therapy, and strength-
training applications.
The design shall accommodate the use of TheraBand clip-connect resistance tubing.
The system shall facilitate progressive resistance training using the familiar TheraBand
resistance-level/color system.
The wall-mounted configuration shall provide a compact footprint suitable for clinical
3. Construction
Main structural components shall be manufactured from high-quality anodized aluminum.
Construction shall be robust and suitable for repeated clinical use.
Surfaces shall be corrosion-resistant and easy to clean and maintain.
The unit shall be designed for secure wall installation and repeated attachment/removal of
exercise accessories
The wall station shall be supplied with a comprehensive accessory package comprising:
Sr. No. Accessory Specification Qty.
Soft-grip handles with D-ring
1 Soft Exercise Handles
2 Extremity Straps Straps with D-ring connector
3 Head Strap Strap with D-ring connector
4 Exercise Posters Full-color instructional posters
5. Exercise and Movement Features
The system shall provide attachment and positioning options allowing exercises to be performed
through three-dimensional planes of movement. It shall be suitable for exercises targeting the arms,
shoulders, trunk, legs, and other major muscle groups as appropriate to a rehabilitation program.
6. Design Requirements
Compact wall-mounted design.
Three-plane/multi-directional movement capability.
Compatibility with TheraBand clip-connect tubing and associated accessories.
Ergonomic accessory interfaces using D-ring connections.
Durable anodized aluminum construction.
Suitable for professional clinical rehabilitation environments.
Parameter Specification
Quantity 1 complete wall station
Overall Width Approx. 900–1,000 mm
Overall Height Approx. 1,800–2,000 mm
Overall Projection from Wall Approx. 150–250 mm
Material High-quality anodized aluminum
Movement Three planes of movement
Mounting Wall-mounted
Resistance Tubing Compatible with TheraBand clip-connect tubing
Upper- and lower-extremity rehabilitation and total-
body strengthening
7. Scope of Supply
The complete system shall include:
1. TheraBand Wall Station.
2. Two soft exercises handle with D-ring connectors.
3. Two extremity straps with D-ring connectors.
4. One head strap with D-ring connector.
5. Two full-color exercise/instructional posters.
6. All standard hardware and components required for installation and normal operation.
8. Quality and Safety
The wall station and accessories shall be manufactured to a high standard of quality and shall be
suitable for repeated use in professional rehabilitation settings. Installation shall be performed using
appropriate wall-mounting hardware suitable for the installation surface and intended clinical load.
9. General terms and conditions:-
Warranty: 2 years comprehensive warranty.
Warranty Coverage: Warranty shall cover the complete unit without any exclusion.
Breakdown Calls: Warranty shall include unlimited breakdown calls without any additional
Service Support: The service provider shall have trained service engineers preferably based in
Surat or nearby Surat, with a service centre in Gujarat or nearby Gujarat for prompt support.
Breakdown Response: Breakdown calls shall be attended within 24 hours and the issue shall be
resolved within 48 hours.
Certification: The unit shall be CDSCO/BIS/CE/USFDA certified, as applicable, and shall comply
with the latest applicable electrical safety standards.
Product Demonstration: On-site demonstration of the quoted product at SMIMER Hospital, Surat
shall be mandatory.
Item No.5 : Shortwave Diathermy
Manufacturer Name : Brand Name : Model Name :
Required Specifications : Specifications available in offered model compared to column (A)
Sr. No. Technical Parameter Required Specification
1. Equipment Short Wave Diathermy (SWD) Unit
2. Application Therapeutic use in physiotherapy
3. Maximum RF Output Power 500 Watt continuous output
4. Operating Frequency 27.12 MHz
5. Wavelength Approximately 11 metres
Continuous mode; pulsed mode preferred, if
6. Operating Modes
7. Output Control Adjustable intensity control
8. Timer 0–30 minutes with automatic cut-off
9. Display Digital or analogue timer and output indicator
10. Tuning System Manual or automatic tuning
Condenser pad electrodes with connecting
leads of high quality.
12. Cooling System Built-in cooling fan, where applicable
220–240 V AC, 50 Hz with ISI quality Indian 3 pin
13. Power Supply
top and 2 meters or more power cable.
Proper earthing, fuse/overcurrent protection
14. Electrical Safety
and applicable electrical safety provisions
Stable trolley-mounted with wheels for easy
15. Mobility movement within the Physiotherapy
Mains cable, electrode leads, pads,
16. Accessories
covers/spacers as required, and user manual
Applicable Indian medical-device regulatory
17. Regulatory Compliance requirements and relevant safety standards,
supported by documentation.
Minimum one-year comprehensive warranty on
the complete unit including the vacuum tube
valve, silicon pads, cable and wheels.Two PMS
must be carried out during the warranty period.
Delivery, installation, demonstration and user
19. Installation and Training
training to be included
Should have a service center or service person
20. Service center in or nearby Surat to attend the breakdown
calls immediately and provide routine PMS.
A separate price list for accessories, valid for
21. List of accessories
one year, shall be provided before installation.
The calibration and testing report certifying that
22. Calibration / Test report the equipment is safe and ready for patient use
shall be provided at the time of installation.
Special conditions:
The manufacturer must confirm that the 500 W rating refers to continuous RF output, not
merely pulsed peak output.
The supplier must provide a technical datasheet, applicable regulatory documents and
warranty details.
The complete system must be supplied ready for clinical use.
Note: All bidders are required to submit the mandatory documents listed in the "Schedule of Documents" on page
Please note that failure to provide any of the required documents will result in disqualification. No additional documents will be accepted
after the submission deadline during the bidding period.
Signature of Tenderer with Seal Medical Superintendent
SMIMER Hospital
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Online Tender-10-2026-27-Physiotherapy.pdf
Online Tech bid for Tender10-2026-27 Physiotherapy.pdf
Online Price bid for Tender10-2026-27 Physiotherapy PB1.pdf
Online Price bid for Tender10-2026-27 Physiotherapy-PB2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .