Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC 122 SAMHARIYA ASOPUR TANDA AMBEDKAR NAGAR UTTAR PRADESH 224190 | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | L1 | Accepted-AOC lowets competative bidder | |
| 2 | L2₹43.2 L+₹1.8 L (4.30%)Rejected-Finance | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹53.8 L+₹12.4 L (29.8%)Rejected-Finance | L3 | Rejected-Finance Rejected being |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Sept 2020, 6:00 pmClosed
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
WELCOME MAINT , DAY TO DAY MAINT AND REPAIR TO JOINERY , PLUMBING, SANITARY , ROOF, PLASTERING AND OTHER CONNECTED BLDG REPAIR WORKS IN AREA I MD ACCCN AND OTHER AREAS OF AGE B/R-1(N) AMBALA CANTT
2020_MES_338625_4
GE(N)Amb-08(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹80,000
Yes
24 Oct 2020
8 Sept 2020
2 Oct 2020
8 Sept 2020
30 Sept 2020
16 Sept 2020
9 Sept 2020 - 16 Sept 2020
Amount
B/R Schedule
M&L rendering 10 mm thick cement plaster in CM 1:3 on concrete surfaces finished even and smooth with out using extra cement on ceiling including taking down cement lime plaster applying three coats of white wash on ceiling complete all as specified and as directed by the Engineer-in-Charge
M&L rendering 15 mm thick cement plaster on fair faces of bricks or concrete walls in CM 1:6 finished even and smooth with out using extra cement on brick work or concrete surfaces including taking down cement lime plaster including applying two coats of Acrylic distemper using painting roller including 2 to 3mm thck wall care putty complete all as specified and as directed by the Engineer-in-Charge
M&L rendering 15 mm thick cement plaster on other then fair faces of brick works in CM 1:4 finished even and smooth with out using extra cement on brick work or concrete surfaces mixed with water proofing compound including taking down cement lime plaster and applying two coats of cement based paint over a coat of primer complete all as specified and as directed by the Engineer-in-Charge
M&L rendering for rough cast plastering including 15 mm thick rendering in cement plaster 1 :3 complete as specified in SSR Part-I clause 14.22 as given .Note : Rough cast finish : After applying under coat of cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied complete including taking down cement lime plaster and applying two coats of cement based paint over a coat of primer complete all as specified and as directed by the Engineer-in-Charge
Complete removing to existing treatment on wall by washing , rubbing,down and stooping and applying applying two coats of Acrylic distemper using painting roller including 2mm thick wall care putty (JK wall / BIRLA white) to make surface smooth in all repair complete all as specified and as directed by the Engineer-in-Charge
Complete removing to existing treatment on wall by washing , rubbing,down and stooping and applying applying two coats of Apex paint over a coat of primex and thin layer of wall putty of complete all as specified and as directed by the Engineer-in-Charge
Complete removal of existing treatment on wall by washing, dwn and stopping and applying two coat of cement based paint complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of of old plastered surfaces of wall and applying two coat of white wash complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed by the Engineer-in-Charge.
Preparation of old surfaces of steel any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
Preparation of old surfaces of wooden of any description not other wise decribed over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
Preparation of old/new surfaces of wooden of any description not other wise decribed over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
S&Fin repair grating doom 100mm dia of PTMT (min weight 25gms) complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 15mm dia size PVC connection with PTMT nuts of length 600mm complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair mild steel powder coated wooden finish curtain rod 25mm dia fixed with decorative brackets, stop roller and glass at the end etc complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair bib taps 15mm dia fency type brass Chromium Plated with long body screwed down for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair brass CP wall/sink mixer for mixing hot & cold water for 15mm bore dia, pipes, screwed down for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge. Note : for Wash hand basin and wall mixer including all connecting fittings except PVC connection)
S&F in repair brass CP WHB mixer for mixing hot & cold water for 15mm bore dia, pipes, screwed down for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge. Note : for Wash hand basin and wall mixer including all connecting fittings except PVC connection)
S&F in repair fancy type pillar tap 15mm bore dia, cast copper alloy with capstan heads, chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
M & L for 75mm bore PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
S&F in repair 15mm bore stop valve, fancy type, brass chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair brass chromium plated tublar towel rail, 20mm dia, D type 60cm long between fkabges complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for 15 mm dia angular stop valves of chromium plated with long shank and cup cocealed type screwed down high pressure with crutch or butterfly handle complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair viterious china white wash hand basin wall hung with pedestal white in colour ISI marked of size 550mm x 410mm x 190mm with chromium plated waste coupling and PVC waste pipe fixed to walls with CI breckets 2 Nos embedded in CM 1:4 type complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs viterous china squatting pan Orrisa pattern size 580 x 440mm white with "P" and "S" trap front or back inlet etc including connectipon to trap and to flishing to pipe , anti syphonage pipe etc incl provisioning of lime concrete complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair vitreous china wash down water closet pan ( pedestal pattern) white including connection to out going pipe and to flushing pipe and antysyphonic pipe etc including seat cover complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 10 ltr PVC valveless syphonic action type flushing cistern with brackets flush pipe etc complete including inlet ball valve float and handle including brackets of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for chromium plated toilet paper holder complete fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for chromium plated shower rose 100mm dia or square including shower arms complete fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair glass sheet assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed by the Engineer-in-Charge.
S&F for chromium plated jet sprey (fusset) for EWC complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for stainless steel sink with out drainage board made of stainless steel 1 mm thick sheet for kitchen with waste coupling waste pipe , washer and including all necessary item including fixing to brackets and connected union to pipe complete of overall size 495 x 420 mm with bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC corner Self(Set of three) fixed with screws complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair plastic water closet seat black closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair stainless steel plate rack standred of min size 750mm x900mm fixing with steel screw and complete all as necessary items complete all as specified and as directed by the Engineer-in-Charge.
S&F for cabinet type looking mirror size 450 mm x 600 mm box type complete all as necessary items complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for 32 mm dia PVC waste pipe for wash hand basin / Kitchen sink etc complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for chromium plated hand shower ( health faucut) with 8 mm dia 1 mtr long flexible tube and wall hook complete fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
M & L in repair for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete including ball valve 20mm dia all as specified and as directed by the Engineer-in-Charge
M & Lin repair for 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete including ball valve 20mm dia all as specified and as directed by the Engineer-in-Charge.
S & F in repair 20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S & F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer-in-Charge
S & F 110mm bore PVC (SWR) bends of any radius, complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) bends of any radius, complete all as specified and as directed by the Engineer-in-Charge.
S&F for 15mm bore `Medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete including taking down GI tubing including taking down existing tubing all as specified and as directed by the Engineer-in-Charge
S&F for 20mm bore `Medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors including taking down GI tubing including taking down existing tubing complete all as specified and as directed by the Engineer-in-Charge
Demolition of cement concrete in ground floors and pavings not exc 15 cm thick below or above G.L. complete all as specified and as directed by the Engineer-in-Charge.
M& L 25mm thick cement concrete 1:2:4 type B1 as in sub base of floors using 20mm stone aggregate, complete all as specified and as directed by the Engineer-in-Charge.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tiles exc 0.11 but not exc 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 15mm cement screed bed in CM (1:4) including dismantling of existing tiles complete all as specified tiles.
M&L for glazed coloured ceramic tiles in vertical surfaces such as skirting /dados and riser to steps area of tiles 350mm x250mm x7mm/450x350x7mm thick set and jointed and pointing in white or coloured cement to match over 10 mm thick plaster in CM 1:4 including dismantling of existing tiles complete all as specified and as directed by the Engineer-in-Charge.
M&L for premium qualty vitrified tiles joint free 10 mm thick (square/ rectangular) area of each tiles exc 0.42 Sqm but n exc 1.00 sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over 15mm cement screed bed in CM (1:4) including dismantling of existing tiles complete all as specified and as directed by the Engineer-in-Charge.
Ditto as per item No 54 above but as in vertical, dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick plaster in CM 1:4 including dismantling of existing tiles complete all as specified and as directed by the Engineer-in-Charge.
M & L for brickwork with sub-class `B` bricks, straight or curved on plan to any radius brick thick walls built in CM 1:4 including dismantling of existing brickwork complete all as specified and as directed by the Engineer-in-Charge
M & L for 20 mm thick granite (Black Jet colour) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding the edges including dismantling of stone slabs complete all as specified and as directed by the Engineer-in-Charge
S&F II class HW 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply of 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (part-1) kiln seasoned and chemically pressure treated and making good to distrubed portion with match the existing surfaces all as specified including taking out of existing shutter, complete all as specified and as directed by the Engineer-in-Charge.
S&F for 35 mm thick II class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc. (with out sash bars) ,edges or framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc and making good distrubed portion with existing surface all as specified including taking out of existing shutter.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification & drawing including taking out of existing shutter complete all as specified and as directed by the Engineer-in-Charge.
S & F Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge. including taking out of existing shutter.
M & L for cutting holes into exc. half brick but not exc. one brick thick walls, built in cement mortar or cement lime mortar and stone walls, for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B1 as required (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall) complete all as specified and as directed by the Engineer-in-Charge
S&F II class HW Plain , Solid ,Straight Chowkhats and frames ,wrought , framed rebated on the solid ,rounded or champhered put together with glue pinned at joints, complete all as specified and as directed by the Engineer-in-Charge.
M&L for 18 mm thick MDF board prelaminated MDF board , exterier grade (grade-1) confirming IS 14587, fixed with screws for kitchen cupboard and cabinet ,self for cupboard including cut edges of prelaminated board to be sealed with 6mm teak lipping and all necessary fittings including dismantling of board of any description and type complete all as specified and as directed by the Engineer-in-Charge.
M&L for 12 mm thick prelaminated partical board interior grade prelaminated both side with decorative choice lamination fixed with screw to timber frame work/aluminium frame work including dismantling of board of any size and type complete all as specified and as directed by the Engineer-in-Charge.
S&F 30mm wide Continuous (piano) hinges, mild steel, bright finish or electrogalvanised fixing to wooden frame complete all as specified and as directed by the Engineer-in-Charge.
S&F 100mm long fency type Stainless steel handles, cast type, polished bright complete all as specified and as directed by the Engineer-in-Charge.
S&F magnet catcher fixed in cabnet shutter (one portion) and wooden frame (other portion) with screw complete all as specified and as directed by the Engineer-in-Charge.
S&F for aluminium section of any size as directed for frame / shutter for door, window, ventilator, and all necessary aluminum hinges complete all as specified and as directed by the Engineer-in-Charge.
M&L for aluminium grill for window and other similar works 10 mm dia including fixing for frame complete all as specified and as directed by the Engineer-in-Charge.
M&L for 4.8 mm thick tinted glass fixed to aluminium frame including rubber bead complete all as specified and as directed by the Engineer-in-Charge.
S & F 100mm long mortice latch with two levers (vertical type), mild steel body complete all as specified and as directed by the Engineer-in-Charge
S&F for framed work as in door of angle or other section with gusset plate , rails , braces, etc complete drilled for fixing of steel sheeting or other covering. Door etc, to be prepared hanging or sliding with and including either hooks and hinges or steel hanging door fitting and hanging also fastening and fixing including one shop coat of zink chromate primer paint confirming to F-410W GDe-250 A complete all as specified including taking out of existing shutter.
S&F for steel window box type double shutter ( glazed with wire gauge)with side hung shutters including hinges with steel handle and steel peg stay complete with glazing bar dovetailed or welded and including window guard bar, tower bolt,flat iron for fixing wire netting including one shop coat of zink chromate primer paint and making good to distrubed portion match with existing surfaces complete all as specified and as directed by the Engineer-in-Charge.
S & F 150mm aluminium handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge
S & F rubber strips 3 to 4 mm thick and 65 to 75 mm wide on bottom rail of door for covering geps between door and floor to avoid entry of inseeds , dust etc, complete all as specified and as directed by the Engineer-in-Charge.
S & F 200mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing for butt hinge ISI Marked 100mm size, medium weight, cold rolled mild steel complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel Hydraulic door closer fixed to chowkats suitable for wooden shutter complete all as specified and as directed by the Engineer-in-Charge.
M & L for hacking out old broken glass exc 1.5 sq m (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by the Engineer-in-Charge
M & L for sheet glass 3.0mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
S & F in repair galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples for new or old door/windows complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair 5mm PVC hollow sheet (wall panelling) inclusive of solvent cement and fixing at site with U clip or PVC frame as per specifications and drawing complete all as specified and as directed by the Engineer-in-Charge
S&F in repair 5-6mm thick mirror including ingraved any pattern, or with wooden beading of any size fixed to wall with CP screwd with top cap and all connected fitting complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering /cladding to wall fixed with self taping screws complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for pre painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering /cladding to wall fixed with self taping screws complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of wooden scantling as in purlins, rafters etc complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel work of angles or tees with tubular , plates cut to shape , drilled and counter sunk for screw , including bending and welding angles as necessary , gusset plates, riveting , etc such as purlin, rafters, post etc confirming to Fe-290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
S & F wash hand basin chinaware including cabinet , drawers complete set as approved by GE including waste coupling bodal trap complete all as specified and as directed by the Engineer-in-Charge.
Taking out existing kitchen cabinets including drewers and refixing in the same position after easing repairing the existing channels , wooden fillets / members (replacement of handles , telescope channel, fillets )boards will be measured & paid seperatly complete all as specified and as directed by the Engineer-in-Charge.
Cleaning of water tanks of any size 500 to 1000 ltr capacity including removel of all scales , dusts etc , opening of stop valva, float valva & refixing in the same position and complete all as specified and as directed by the Engineer-in-Charge.
Cleaning of bushes , removel of trees , vegetation not exc from wall , roof not exc 30 cm girth, complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L concrete bed to drain pipes of 110 mm bore including packing under and harching against the sides of pipes after they are laid and tested in PCC 1:3:6 type C1 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of brick tiles single layer laid on roofs etc complete all as specified and as directed by the Engineer-in-Charge.
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and as directed by the Engineer-in-Charge.
M & L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed by the Engineer-in-Charge.
M & L for brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in roof kerbs, mud stops , padding or filling roof depressions finished even and smooth with out using extra cement etc, complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3, complete, all as specified and as directed by the Engineer-in-Charge.
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25'C temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shell be under ;- (i) Joint strength in longitudinal and transverse direction at 23'C at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150'C when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
M&L 40mm thick Brick tiles laid over and including 15mm thick layer of screed bed of cement mortar 1:6 and joints grouted with 5 % of crude oil by weight of cement complete all as specified and as directed by the Engineer-in-Charge.
All as per Srl item No 2.04 above but except bricks and -ditto- complete all as specified and as directed by the Engineer-in-Charge.
E/M Schedule
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit ot less than 20 mm dia with accessories, concealed/surface type on wall/ceiling and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volts grade ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes (modular type, size/modules as required at site) with and including screws, washers and modular covere plate over sunken box for housing the modular switches , socket outlets & fan regulators etc and making good the disturbed surfaces as per existing for:- One light point/bell/fan point controlled by one switch. Note:-1. Modular metal flush/sunken Box alongwith modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 2. Only switch, socket and fan regulators to be measured and paid separately.
All as per Item No. 3.02 here-in-before but One 3 pin socket point 5 Amps on independent board, complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 3.02 here-in-before but One 3 pin socket point 5 Amps on same board, complete all as specified and as directed by the Engineer-in-Charge
All as per item No 3.02 here-in-before but for one socket point 15 Amp with 4 sq mm PVC unsheathed FRLS-H, 1100 volts grade ISI marked with multi stranded copper conductor cable along with 4 sq mm green colour FRLS-H, 1100 volts grade ISI marked copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge
S&F modular switch 6 Amp 1 way 1 module 230 volts including disconnecting and taking down existing old U/S complete all as specified and as directed by the Engineer-in-Charge
S&F switch modular 16 Amp 1 way 1 module 230 volts including disconnecting and taking down existing old U/S complete all as specified and as directed by the Engineer-in-Charge
S&F socket modular 2/3 pin 5 Amp 2 module 230 volts including disconnecting and taking down existing old U/S complete all as specified and as directed by the Engineer-in-Charge
S&F socket modular 6 pin 6/16 Amp 2 module 230 volts including disconnecting and taking down existing old U/S complete all as specified and as directed by the Engineer-in-Charge
S&F of electronic Fan regulator modular 100 watt 2 module including disconnecting and taking down existing old U/S complete all as specified and as directed by the Engineer-in-Charge
S&F modular bell push 6 Amp 1 way 1 module 230 volts including disconnecting and taking down existing old U/S complete all as specified and as directed by the Engineer-in-Charge
S & F Calling bell ding dong type SP AC supply, 230 volts including disconnecting and taking down existing old U/S complete all as specified and as directed by the Engineer-in-Charge
Supply and fix ceiling rose surface type 2/3 terminal including disconnecting and taking down existing old U/S complete all as specified and as directed by the Engineer-in-Charge
Supply and fix lamp holder, insulated body, with back plate for angular batten fittings including disconnecting and taking down existing old U/S complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing LED batten fitting 18-20 watt, 4 feet, aluminium body including driver, tube rod cool/warm white industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing LED batten fitting 10-12 watt, 2 feet, aluminium body, including driver, tube rod cool/warm type, industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing LED surface mounted bulk head luminaries 8-10 W with min 800 lumen, industrial model, IP 65, Aluminum housing, surge protection including drivers & LED lamp etc complete with all accessories connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by the Engineer-in-Charge
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB 20 Amp including removing old Unserviceable enclosure complete all as specified and as directed by the Engineer-in-Charge
Supply and fix sheet metal MCB DBs 8 way with 200 Amps rated bus bar single pole and neutral IP-43, double door fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surface after removing old Unserviceable MCB DB complete all as specified and as directed by the Engineer-in-Charge
Supply and fix sheet metal enclosure Vertical triple pole & neutral (VTPN) with TPN MCCB 125 Amp for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge
Supply and fix MCB SP 6-32 Amps, 240 volt, 10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge
Supply and fix RCBO 40 Amps 2 Pole, 2 module 100 mA (HI immunity) sensitivity 230 volts 50 Hz, including removing old Unserviceable RCBO complete all as specified and as directed by the Engineer-in-Charge
Supply and fix in repair over voltage release 230 V, single phase in one module complete all as specified and as directed by the Engineer-in-Charge
S&laying sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volt grade ISI marked with multi stranded copper conductor with one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified including taking out of old U/s sub main wiring of any size . Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
All as per srl item No 3.24 here-in-before but submain wiring with 10 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volts grade ISI marked with multi stranded copper conductor cable, complete all as specified and as directed by the Engineer-in-Charge
Refixing only existing serviceable LED light fittings of any description after cleaning complete all as specified and as directed by the Engineer-in-Charge
Refixing only existing serviceable switch 5 Amps with sunken boxes of any type after cleaning complete all as specified and as directed by the Engineer-in-Charge
Refixing only existing serviceable switch 15 Amps with sunken boxes of any type after cleaning complete all as specified and as directed by the Engineer-in-Charge
Refixing only existing serviceable socket 15 Amps with sunken boxes of any type after cleaning complete all as specified and as directed by the Engineer-in-Charge
Refixing only existing serviceable socket 5 Amps with sunken boxes of any type after cleaning complete all as specified and as directed by the Engineer-in-Charge
Refixing only existing serviceable fan regulators with sunken boxes of any type after cleaning complete all as specified and as directed by the Engineer-in-Charge
Refixing only existing PVC conduits of any description by providing new GI/PVC saddles as per site requirment complete all as specified and as directed by the Engineer-in-Charge
bhagwandasswazirchand
Karishan Kumar goel
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .