| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.5 LAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹59.2 L+₹2.8 L (4.99%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹59.8 L+₹3.5 L (6.14%)Rejected-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L3 | Rejected-AOC Rejected |
Tender Value
₹58.4 L
EMD Value
₹1.1 L
Closing Date
2 Jun 2025, 6:00 pmClosed
CWE (NW) KOCHI
CWE (NW) KOCHI
COMPREHENSIVE MAINTENANCE AND REPAIRS TO PASSENGER AND GOODS LIFTS OF DERA COMPLEX, VARSHA, VARUNA, TARANGINI, FERSON AND DAWSON VIHAR APARTMENTS AT SATELLITE AREA IN KOCHI UNDER GE(NW) KOCHI
2025_MES_705778_1
CWE(NW)KOCHI/81539
Open Tender
Civil Works
Item Rate
365 days
CWE (NW) KOCHI
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE(NW) KOCHI
₹1.1 L
Yes
4 Jul 2025
28 Apr 2025
4 Jun 2025
28 Apr 2025
2 Jun 2025
19 May 2025
Amount
Comprehensive Maintenance, Repairs including AMC and Periodical Servicing of lift shall be done through OEMs/ Authorised agency, of following electrically operated Passenger and Goods lifts complete with Electrical / Control Panels and all connected Gadgets / Devices incl ARD's including removal/replacement of defective parts and sundry item viz grease, lubricant oil, cotton waste, small pieces of cable, lugs, including all spares like PCBs, Bearing, Relay, Door Motor repairing / replacement, COP Button, Din Rail, Contactor, SMPS, Door guide shoe, cabin fan, stop switch, indicator, Belt, pully, Hardware card, reed switch, Pushbutton, Auto door contact, car door skate, DC contactor, DC relay, Alarm unit, door latch , PVC vinyal sheet, VVVF drive, door sensors and drivers of any type, size, make, batteries for ARD/ UPS of any type, size, capacity, make, blower fans, cabin lights and speaker phone etc for running the lift smoothly as per user satisfaction for different capacity lifts at various locations of satellite area kochi as per details given below:-
08 Passenger lift No. 1 at Chandrasekhar Apartments. Make: Thyssenkrupp Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 12 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
08 Passenger lift No. 2 at Chandrasekhar Apartments. Make: Thyssenkrupp Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 12 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
13 Passenger lift at Chandrasekhar Apartments. Make: Thyssenkrupp Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 11 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
13 Passenger lift at Panigrahi Apartments. Make: Johnson Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 12 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
08 Passenger lift at Nalinakshan Apartments. Make: Thyssenkrupp Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 8 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
Passenger cum Goods lift 1000Kg at Nalinakshan Apartments. Make: Thyssenkrupp Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 8 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
08 Passenger lift Block IA at Dawson Vihar Complex. Make: Thyssenkrupp Speed 1- 1.5 M/Sec, Geared, Drive - V3, Floor G + 7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
Passenger cum Goods lift 1000Kg Block IA at Dawson Vihar Complex. Make: Thyssenkrupp Speed 1- 1.5 M/Sec, Geared, Drive - V3, Floor G + 7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
08 Passenger lift Block IB at Dawson Vihar Complex. Make: Thyssenkrupp Speed 1- 1.5 M/Sec, Geared, Drive - V3, Floor G + 7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
Passenger cum Goods lift 1000Kg Block IB at Dawson Vihar Complex. Make: Thyssenkrupp Speed 1- 1.5 M/Sec, Geared, Drive - V3, Floor G + 7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
08 Passenger lift Block IC at Dawson Vihar Complex. Make: Thyssenkrupp Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
08 Passenger lift Block IIA at Dawson Vihar Complex. Make: Thyssenkrupp Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
Passenger Cum Goods lift 1000 Kg Block IIA at Dawson Vihar Complex. Make : OTIS Speed 1 - 1.5 M/Sec, Geared, Drive - V3, Floor G+7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen.
08 Passenger lift Block IIB at Dawson Vihar Complex. Make: Thyssenkrupp Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
Passenger Cum Goods lift 1000 Kg Block IIB at Dawson Vihar Complex. Make : OTIS Speed 1 - 1.5 M/Sec, Geared, Drive - V3, Floor G+7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen.
08 Passenger lift Block IIIC at Dawson Vihar Complex. Make: Thyssenkrupp Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 7 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
13 Passenger lift 884 Kgs at Varsha Apartments. Make: Kone Elevator India Pvt. Ltd. Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 9 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen (Lift No. 1)
13 Passenger lift 884 Kgs at Varsha Apartments. Make: Kone Elevator India Pvt. Ltd. Speed 1-1.5 M/Sec, Geared, Drive - V3, Floor G + 9 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen (Lift No. 2)
08 Passenger lift at Viswanathan Apartment. Make: Otis Speed 1- 1.5 M/Sec, Geared, Drive - V3, Floor G + 10 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
Passenger cum goods lift 1000 Kgs at Viswanathan Apartment. Make: Otis Speed 1- 1.5 M/Sec, Geared, Drive - V3, Floor G + 10 all safety precautions like door lock, limit switch, over speed governer, car top stop and IR screen
Note for item No.1 (i) Spare parts other than those included in item No.1 and incorporated in Sch 'A' which required for lift maintenance / repair / replacement shall be genuine and orignal equipment manufcturer will be measured and paid seperately. (ii) Customer Care Contact Number of the repair / rescue agency is to be displayed at each lift. The firm should attend defects / breakdown calls of all ifts round the clock and repair rescue action to be initiated immediately with out delay. Record for the same is also to be maintained and updated telephonically to the Engineer in Charge. (iii) Well trained, Certified Technicians are to be employed at site for Lift Maintenance. The technicians employed by the firm should have thorough knowledge of all types / makes / models of lifts. Prior approval in this regard is to be obtained from accepting officer. (iv) The work will be of continous in nature without Sundays, Holidays or Strikes and the contractor must employ Lift Technicians for the Lift Maintenance round the clock as and when necessity arises. (v) The technician should ensure the serviceability of the Lifts for every odd situation. The contractor should ensure full safety and functionability of the assets being maintained by him. Any casualty or injury sustained by the technician during the currency of contact at the defence premises shall be sole liability of the contractor. No claim on this account shall be entertained by the Department. (vi) All Tools & Plants or Transport required for carrying out Comprehensive Maintenance and necessary stationary & documents (log books, test records etc.) for maintaining the recods at each lift installation will be arranged by the contractor and nothing extra will be admissible on this account. (vii) The quoted rates are deemed to be included for provision of communication facility by technician with JE / AGE / GE or with Testing agencies.
(viii) The rate quoted by contractor shall deem to be included for cleaning of the Lift Machineries, Lift Panels, Lift Rooms, Lift Car Cabin, Lift Well, LIft Shaft etc. for keeping the lift installation neat and tidy in all the manners and all inspections by higher authorities. (ix) The contractor should ensure all provions as laid down by State / Central Govt. labour commissions, Employees Provident Fund, ESI and in Contract Labour Act 1970 such as payments of minimum fair wages, working conditions etc. are complied. (x) The spare parts shall be genuine and origional equipment manufactorer (OEM) as approved by GE and all purchase vouchers to be produceed in origional. (xi) Comprehensive maintenance of lifts shall be done through origional equipment manufacturor or authorised agency (xii) All labour cost and other sundry items lik nuts, bolts screws, washers, lubricants etc are deemed included in the quoted rate. (xiii) Contractor needs to carryout fort nightly (15 days), Monthly, Quarterly and Half yearly tests as specifiedd in particular specification of this CA and submit report for each lift in triplicate includes all necessary stationery items. (xiv) The contractor shall submit MoU/Authorisation letter from OEM for maintenance /repair/AMC of all the lifts before commencement of work. (xv) The lifts to be keep in running condition at all the time. If the complaint/break down of lifts occured shall be rectified within 3 hours of notification. If the complaint /break down has not rectified within 3 hours a penalty of Rs. 1000.00 will be levied from the contractor for every hour. (xvi) The contractor shall viit the site examine carefully the type of lift and its present condition and make himself familiar with the nature of maintenance works required to be carried out. (xvii) The spares shall be mesuared as supply under relevant items of BOQ.
Material & Labour for load testing of all above lifts with 120% load in presence of the license holder of OEM, Contractor Rep and Engr-in-Charge all as specifiedd and as directed.
Supply the following spares :-
Car top inverter battery 12 V, 7 AH
ARD Battery 12 V, 12 AH
ARD Battery 12 V, 17 AH
Variable voltage, variable frequency unit for OTIS / Johnson/ Thyssenkrupp Lifts
VVVF Door Drive suitable for Thyssenkrupp/ OTIS/ Johnson Lifts
Mother board card, TIC-2
Infrared door screen of 2 meter height suitable for any type of lifts
Lift car of fan 350 mm sweep
ARD unit with uninterrupted power supply for lifts voltage input 220-240 Volt, 1 KVA – 2.2 KVA including suitable capacity of batteries
Complete ARD system 3 phase, 2 phase with suitable type batteries
Lift Car Cabin Top UPS 230V, 600 VA.
Recessed mounted LED light 3 to 5 Watt, min 120 Lumen/Watt, 230 Volts, 50 Hz with fittings and fixtures complete all as specified and as directed by Engr-in-Charge.
SMF Battery 12 Volts 18 AH complete all as specified and directed by Eng-in-charge
Landing Operating Panel complete all as specified and directed by Eng-in-charge
Landing Operating Display PCB complete all as specified and directed by Eng-in-charge
Mother Board complete all as specified and directed by Eng-in-charge
Door motor encoder complete all as specified and directed by Eng-in-charge
IR Door sensor complete all as specified and directed by Eng-in-charge
Encoder card complete all as specified and directed by Eng-in-charge
Door driver complete all as specified and directed by Eng-in-charge
Car door contact complete all as specified and directed by Eng-in-charge
Landing door contact complete all as specified and directed by Eng-in-charge
Car guide shoe complete all as specified and directed by Eng-in-charge
Read Switch complete all as specified and directed by Eng-in-charge
Door Synchronization Rubber belt upto 2 m length complete all as specified and directed by Eng-in-charge
Door Hanger Roller complete all as specified and directed by Eng-in-charge
Door eccentric roller complete all as specified and directed by Eng-in-charge
Landing door synchronization rope multi stranded of size 3 mm complete all as specified and directed by Eng-in-charge
Limit Switch 110 V, 10 Amp complete all as specified and directed by Eng-in-charge
Break Coil 110 V DC complete all as specified and directed by Eng-in-charge
Relay 110 V, 6A, AC 2/3 Pole complete all as specified and directed by Eng-in-charge
Relay 24 V, 5A DC complete all as specified and directed by Eng-in-charge
SMPS 24 V DC 6 A complete all as specified and directed by Eng-in-charge
SMPS 5 V DC 5 A complete all as specified and directed by Eng-in-charge
Fire man glass assembly unit with fireman switch complete all as specified and directed by Eng-in-charge
Lift car top fan metal/PVC body 300 mm sweep complete all as specified and directed by Eng-in-charge
Single phase preventer complete all as specified and directed by Eng-in-charge
Toggle Switch complete all as specified and directed by Eng-in-charge
Alarm unit comprising of PCB, battery with indication lamp and speaker 20 W complete all as specified and directed by Eng-in-charge
Floor Announicater system (FAS) with PCB complete all as specified and directed by Eng-in-charge
COP display complete all as specified and directed by Eng-in-charge
Blower Fan FB- 9B AC 220 V/50 Hz/22 W complete all as specified and directed by Eng-in-charge
AISWARYA ENTERPRISES (BID ID -3309684)
M/s Dhapola Elevator and Engineering (BID ID -3309995)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .