Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
26 Jul 2021, 6:00 pmClosed
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-20/2021-22 CERTAIN SANCTIONED LBWS AND SPECIAL REPAIR WORKS OF 867 FD WORKSHOP, 640 EME BN, 47 FD WORKSHOP AND 148 FD WORKSHOP UNDER AGE B/R-I(NORTH) OF GE (NORTH) AMBALA CANTT
2021_MES_453485_1
GE(N)Amb-20/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹90,000
Yes
14 Oct 2021
28 Jun 2021
28 Jul 2021
28 Jun 2021
26 Jul 2021
12 Jul 2021
28 Jun 2021 - 12 Jul 2021
Amount
Schedule 'B' Part-I (B/R itmes) Surface excavation not exceeding 30cm deep and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removal of excavated material to a distance not exc. 50 m and depositing at a level nexc 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 CM thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits and sides of roof beams,lintels over 1.5 metre span for rough finished surfaces of concrete flats complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits of chajjas including sides for rough finished surfaces of concrete flat complete all as specified and as directed by the Engineer-in-Charge.
Formwork to sides of pillars, posts,struts, piers, columns and stanchions flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregates in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate in chajjas complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in pillars, posts,struts, piers, columns and stanchions complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 5 mm dia upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 6 to 8 mm dia cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks in half brick thick wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc. 63mm, deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M&L moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed by the Engineer-in-Charge.
M&L treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed by the Engineer-in-Charge.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed by the Engineer-in-Charge.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by the Engineer-in-Charge.
M & L 100 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete , of frame size 165 x 60 mm, made from 1.25mm thick plain black iron sheet complete all as specified and as directed by the Engineer-in-Charge.
M&L for providing cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.0mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by Engineer in Charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill fabricated from 10mm square MS bar as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately.
S&F Galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 10 mm thick on fair faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rendring 15mm thick in cement plaster 1:6 on any faces of brick work or concrete wall surfaces and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in charge.
M&L rendering 15 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:4 using water proofing compound and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge. ( water proofing compound shall be measured and paid for separately) .
M&L rough cast plaster complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:3 not less than 15 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of celing and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer with painting roller complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing new plastered surfaces of wall and applying two coats of oil emulsion distemper with painting roller over and including 1 to 2mm thick wall care putty white cement based in two or more coats to achieve smooth surfaces complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing new plastered surfaces and applying two coats of exterior emulsion paint over a coat of primer with painting roller on surfaces of walls, chajjas, roof projection complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 9 to 10 mm thick, area of each tile exc 0.18 sqm but not exc 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/skirtings/dados of size 350x250x7mm/450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
M & L providing 50 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
M&L rolled mild steel framed work as in chowkats door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410-W (Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm prelam PVC sheet on single side used instead of plain colour PVC sheet reinforced with MS square tube, edges will be painted to match with prelam sheet and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
S&F box type using ERW hollow 'P' section ventilators glazed/gauged including MS grills of square bar 10mm dia @ 100 c/c complete with glazing bars dovetailed or welded, including two coat of synthetic enamel ordinary tint paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
M&L prepration of new wooden surface and apply two coats of synthetic enamel paint over a coat of pink primer on surface of any description , not otherwise described over 10cm width or girth complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new steel surface and applying two coats of synthetic enamel ordinary tint paint over a coat of red oxide primer on steel or iron surfaces of any description over 10cm in width or grith, not otherwise described complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing stainless steel butt hinges 100 mm long medium weight and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 150 mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe) but including brass chromium plated spreader, PVC waste pipe , providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern) including plastic water closet seat white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device and brass chromium plated Jet spray with PVC with complete accessories complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves fancy type with long shank and cup (concealed), screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy angular type chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type bib tap 15mm bore cast copper alloy chromium plated long body with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated toilet paper holder complete fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S&F 100mm bore PVC (SWR) vent cowl complete all as specified and as directed by the Engineer-in-Charge.
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 mm wide with chromiun plated brackets guard and railing 60 cm long complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing pillar tap 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 100mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S&F 125 mm dia brass chromium plated shower rose swivel type with arms of standard length complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors or fixed to walls complete all as specified and as directed by the Engineer-in-Charge .
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors or fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC(SWR) bends of any radius, diminishing pieces or tapers (larger bore measured ) complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC(SWR) bends of any radius, diminishing pieces or tapers (larger bore measured )complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and as directed by the Engineer-in-Charge.
S & F 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) tripple layer body, 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I, complete all as specified and as directed by the Engineer-in-Charge. Note : Water storage tank shall be White in colour.
S&F 20mm bore Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
M&L for 10mm thick cement plaster in CM 1:4 on roof slab mixed with water proofing compound, surface finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for speartely
M & L carring out roof treatment consisting of following:- (a) Cleaning of plastered roof surface by sweeping and washing down with water to remove dust etc, (b). Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shell be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
M & L cutting into existing manholes for connecting new drain, making good to pipe 150 mm dia and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and as directed by the Engineer-in-Charge.
M & L precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete with joints to match, except blocks or slabs complete all as specified and as directed by the Engineer-in-Charge.
M&L Machine pressed rubber moulded coloured precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge.
M & L for providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M&L for providing precast ce- ment concrete 1:2:4 type B-1(20mm graded crushed stone aggregate) in win- dow or door cills and setting in mortar 1:4 complete with joints to match complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel powder coated wooden finish curtain rod 25mm dia fixed with and including decorative brackets ,stop roller and glass at the end etc complete all as specified and as directed by the Engineer-in-Charge.
M & L stack clamp out of 50mm x5mm flat iron stays including bolt and nuts and securing ends of stays to walls or roof for 100mm bore pipe complete all as specified and as directed by the Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 Type B2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe-410-W(Gde E-250) quality-B complete all as specified and as directed by the Engineer-in-Charge.
M&L rolled mild steel compound girders and stanchions, as in vertical section, llattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. of Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed by the Engineer-in-Charge.
S&F plates (plain or chequered) Channels, square, cut or notched (ordinary and counter sunk) forming holes without any attachment of Fe-410-W (Grade E-250) quality B complete all as specified and as directed by the Engineer-in-Charge.
S & F 150mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge.
M&L for concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports complete all as specified and as directed. Note:-(i) Thickness of bed belew barrel of pipe -10 cm (ii) Width of bed :- outer dia of pipe plus 30 cm.
Dismantling of plain or corrugated asbestos cement sheet of any thickness incl Nainital or similar pattern coverings, complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 gm per Sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150gm/Sqm (Az-150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and as directed by the Engineer-in-Charge.
M&L Double charged vitrified tiles joint free 10 mm thick, 1st quality (square/ rectangular) area of each tiles not exc. 0.36 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 15mm cement screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L Double charged vitrified tiles joint free 10 mm thick, 1st quality (square/ rectangular) cut from area of each tiles not exc 0.36 Sqm in skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates confirming to Fe-410-W (Gde- E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
Dismantiling timber framed work scantling 40 Sqm cm and over in section in any position complete all as specified & directed by the Engr-in-Charge.
M & L complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, wasing down with water to remove loose particles etc and applying two coats of oil bound distemper with painting roller complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on walls, pillars, cornices etc (any number of layers) by scrapping with steel scrappers or any other means, wasing down with water to remove loose particles etc and applying two coats of cement base paint complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old previously treated wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
Schedule 'B' Part-II (E/M itmes) Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 121 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 121 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and incuding provision of 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Material and labour for Point wiring with 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and incuding provision of 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 16amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,with one PVC block of size 75mm x75mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED Bulb, retrofit 9 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
Supply and fix TV modular socket 2/3 pin, 5 Amp, 1 way, 2 module of complete all as specified and as directed by Engineer-in-Charge.
S&F step type electronic Fan regulator modular 120 watt, 2 module complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB single pole, 240 volt, 6 to 40 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing of SPN distribution board 12 way, double door, IP 43, as per IS 8623 including 200amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimble, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix RCBO 40 Amps, 2 Pole, 300 mA (HI immunity) sensitivity, 230 volts, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing of SPN distribution board 8 way, double door, IP 43, as per IS 8623 including 200amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimble, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole and netural, 240 volt, 32 to 40 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve complete all as specified and as directed by the Engr-in-charge.
Supply and fix over and Low voltage release 1 module, 230 volts AC, suitable for single phase adjustabe from 170 volts to 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix over and Low voltage release 1 module, 230 volts AC, suitable for three phase adjustabe from 170 volts to 230 volts complete all as specified and as directed by Engineer-in-Charge.
S & laying sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supplying and fixing 1100 volts grade heavy duty cable 16 Sqmm muilti stranded aluminium conductor, PVC insulated served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-Charge.
Supplying and fixing 1100 volts grade heavy duty cable 10 Sqmm muilti stranded aluminium conductor, PVC insulated served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-Charge.
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing indoor decorative LED tube light fitting Batten type 18/20 watt with opal diffuser, high efficient aluminium housing body in CRCA body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 18/20 watt LED tube rod luminaries (Warm/Cool as per site requirement) environment friendly, high efficient, T8 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
S & F recess mounted indoor decoraative, vertically/horizontally mounting, top opening, LED light fitting 2'x2' box type with a unique drop down opal diffuser, leading to uniform lighting experience illuminating high efficient aluminium housing body in CRCA body suitable for LED, high efficient, AC 220-240 volts, 50 Hz and including 36-40 watt LED luminaries (Warm/Cool as per site requirement) environment friendly , aluminium extrusion heat sink and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
S&F mirror light 9/12W LED wall mounting fixture, aluminium housing compact & energy efficient epoxy powder coated CRCA light luminaire, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
S & F decorative indirect post top LED light fitting for gate light and landscape lighting with IP 65 protection, resistant to impact and corrosin, anti glare & uniform distribution of 45/60watt cap LED with all mounting fixture, compact & energy efficient epoxy powder coated CRCA light luminaire complete all as specified and as directed by the Engr-in-charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection complete all as specified and as directed by the Engineer-in-Charge.
S&F light grade GI Tubing of size 40 mm dia for cable protection and fixed with clamp to pole and wall with nut, bolts and washers complete all as specified and as directed by the Engineer-in-Charge.
Material & labour earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron wire earth lead of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron, earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
Supply & Fix Water heater (Geyser) storage type electric of capacity 25 Ltrs , BEE 5 Star rated, ABS body, metal tank with glasss lined coating, multiple heating option, shock safe plug, puf insulation, incoloy glass coated anode rod / copper heating element of capacity 2KW with ISI mark , adjustable knob for temp setting with minimum 8 Bar high working pressure, multi functional safety valve & whirl/Swirl flow technology, thermostat electronic type, thermal cutout capillary type complete including superior quality copper connection pipe heavy duty 15mm dia 450mm long, brass adopter for water connection with nikhel coated ISI marked with fastner, nut bolts, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per existing surface, connecting to inlet and outlet valves, testing complete all as specified and as directed by Engineer-in-Charge. Note :- Warranty certifcate to be produced by the Contractor from OEM for the following components before processing the bill. a) for Product - 02 Years b) for Heating element - 03 Years c) for metal tank - 07 Years
Supply and fix ceiling fans, AC, single phase, 230 V, 50 Hz, copper wounded of 1200 mm sweep with BLDC technology , max power input up to 35 watt, copper wire induction motor with 5 star BEE ratings, including remote and set of batteries complete along with canopy cover, down rod 'U' clamp, 3 core PVC flexible cable 1sqmm for making connection of fan and hanging the fan in clamp, connecting with electrical connection all as specified and as directed by Engr-in-charge. Note ; - MES No shall be written by the contractor with permanent marker over ceiling fan of specified size and colour and quoted rate shall be deemed to be included of this element.
M & L rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and as directed by Engineer-in-Charge.
Sham Sunder Bansal
MAYANK ENTERPRISES
bhagwandasswazirchand
Swami Enterprises
M/s Vridhi Construction Co.
Durga Enterprises
SMT Construction
singh traders
Karishan Kumar goel
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .