Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC | ₹43.3 L Quoted ₹43.4 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹45.6 LRejected-AOC | ₹45.6 L | L2 | Rejected-AOC Not Lowest Bidder |
| Sl No | Description | Qty | Unit | JAMWAY MATA CONSTRUCTION COMPANY L1 | Savitri Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below/above ground level) including floor finishes & removing debris outside the premises complete all as specified & directed by the Engineer-in-Charge. | 13.37 | Cum | 800 ₹10,696 | 100 ₹1,337 |
| 2.00 | Taking down old existing roof treatment(APP membrane) and removing from site complete all as specified and as directed | 1,750 | Sqm | 100 ₹1.8 L | 10 ₹17,500 |
| 3.00 | Demolition of cement concrete of any type description and in any position complete including removing debris outside the premises complete all as specified & directed. | 50.2 | Cum | 800 ₹40,160 | 100 ₹5,020 |
| 4.00 | Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified. | 350 | RM | 50 ₹17,500 | 150 ₹52,500 |
| 5.00 | Brushing neat cement slurry with 3kg of cement per Sqm complete all as specified. | 1,120 | Sqm | 50 ₹56,000 | 30 ₹33,600 |
| 6.00 | M & L for 40 mm thick cement concrete 1:2:4 type B-0 m (12.5 mm graded stone aggregate) in padding finishing surface of concrete topping even and smooth without using extra cement complete all as specified. | 1,120 | Sqm | 240 ₹2.7 L | 340 ₹3.8 L |
| 7.00 | M & L for cement concrete 1:2:4 type B-0 (12.5 mm graded stone aggregate) in tank platforms even and smooth without using extra cement complete all as specified. | 9 | Cum | 240 ₹2,160 | 4,000 ₹36,000 |
| 8.00 | M & L for 10mm thick plastering in cm 1:3 on green concrete roof surfaces with water proofing compound @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified.. Note :- WPC shall be measured and paid separately. | 1,788.48 | Sqm | 210 ₹3.8 L | 220 ₹3.9 L |
| 9.00 | Supply only integral water proofing compound ISI Marked | 451.53 | Kg | 48 ₹21,673.44 | 50 ₹22,576.50 |
| 10.00 | M&L APP modified membrane minimum weighting 3 Kg/Sqm and minimum 3mm thick with polyster non woven polyster reinforcement ( weight not less than 150 gms/sqm )shall be laid by torch application method and overlapped by 100 mm in all sides including applying evenly a tack coat of industrial bitumen 85 / 25 @ 1.20 Kg per Sqm including cleaning of surface as directed by Engr-in-Charge. | 1,750 | Sqm | 400 ₹7 L | 400 ₹7 L |
Updated dates
Tender Value
₹49.3 L
EMD Value
₹98,680
Closing Date
13 Dec 2025, 6:00 pmClosed
GE (AF) No.2 Jodhpur
GE (AF) No. 2 Jodhpur AF Stn Jodhpur
Special repair to roof treatment at certain Building at Site 1B Provn of certain Works services for 751 SU Provn of Washroom at shoping Complex Provn of Grease trap for sullage at DSC Mess Provn of Steel gate at Site 1A Provisioning and Installation
2025_MES_740052_1
8555/E8
Open Tender
Construction Works
210 days
GE (AF) No.2 Jodhpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) No. 2 Jodhpur
₹98,680
Yes
9 Jan 2026
15 Nov 2025
15 Dec 2025
15 Nov 2025
13 Dec 2025
1 Dec 2025
15 Nov 2025 - 22 Nov 2025
Amount
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below/above ground level) including floor finishes & removing debris outside the premises complete all as specified & directed by the Engineer-in-Charge.
Taking down old existing roof treatment(APP membrane) and removing from site complete all as specified and as directed
Demolition of cement concrete of any type description and in any position complete including removing debris outside the premises complete all as specified & directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified.
Brushing neat cement slurry with 3kg of cement per Sqm complete all as specified.
M & L for 40 mm thick cement concrete 1:2:4 type B-0 m (12.5 mm graded stone aggregate) in padding finishing surface of concrete topping even and smooth without using extra cement complete all as specified.
M & L for cement concrete 1:2:4 type B-0 (12.5 mm graded stone aggregate) in tank platforms even and smooth without using extra cement complete all as specified.
M & L for 10mm thick plastering in cm 1:3 on green concrete roof surfaces with water proofing compound @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified.. Note :- WPC shall be measured and paid separately.
Supply only integral water proofing compound ISI Marked
M&L APP modified membrane minimum weighting 3 Kg/Sqm and minimum 3mm thick with polyster non woven polyster reinforcement ( weight not less than 150 gms/sqm )shall be laid by torch application method and overlapped by 100 mm in all sides including applying evenly a tack coat of industrial bitumen 85 / 25 @ 1.20 Kg per Sqm including cleaning of surface as directed by Engr-in-Charge.
Forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30cm thick, watering, ramming/rolling and finishing to required size, shape, etc., including supply of approved earth obtained from Air Force campus or from with Air Force station if approved including excavation and carrying to work site and including surface dressing not exceeding 15cm deep and cleaning away all grass, vegetation, saplings, shrubs, bush wood under growth roots, soft/loose soil etc and removal of old soil etc complete all as specified and directed.
M&L for Providing cement concrete 1:2:4 Type B0 using 12.5 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified..
Disconnecting existing tanks of capacity 500 ltr to 1000 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing etc. measured separately).
Dismantling of existing water tank (PVC/RCC/AC) exc 500 ltr but n exc 1000 ltr capcity and removing from site to store yard complete as directed by Engr -in-charge.
Dismantling of existing water tank (PVC/RCC/AC)exc 250 ltr but n exc 500 ltr capcity and removing from site to store yard complete as directed by Engr -in-charge.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl 20mm bore ball PTMT. valve high pressure with polythyne float and flynut complete.
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl 20mm bore ball PTMT. valve high pressure with polythyne float and flynut complete.
Demolition and breaking up 100/150mm dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar
S&F for PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to wall of 110 mm dia complete all as specified and directed by Engr-in-Charge.
S&F for PVC(SWR) bend of 110 mm dia.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 15 mm complete all as specified.
S&F 15 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
Refixing old steel tubing and connections in new or old position as in walls ceiling floors etc bore of pipe 15mm complete all as specified.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 20 mm complete all as specified.
S&F 20 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
Refixing old steel tubing and connections in new or old position as in walls ceiling floors etc bore of pipe 20mm complete all as specified.
S&F in repair Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 15 mm dia complete all as specified.
S&F in repair Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20 mm dia complete all as specified.
Taking down and refixing the earthing strip over the finished roof surfaces, fixed on batten or any other indicated situation complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc.30 cm deep and averaging 15 cm deep and getting out soft/loose soil all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out as soft soil all as specified and directed.
Removing excavated material exc. 1.5km but n exc. 5 m and depositing where directed complete all as specified.
M & L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
M&L Cement concrete type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass-concrete complete all as specified and directed.
Formwork to flat Rough finished surfaces of concrete sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to better complete all as specified and directed.
Formwork square, rectangular or polygonal to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
Formwork to flat Rough finished surfaces of concrete sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed
Formwork to flat Rough finished surfaces of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide
S&F for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,Beams,footing, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
S&F for TMT steel bars 6-8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slab,hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M & L RCC nomonal mix 1:1.5:3, Type B1(20 mm graded aggregate) for foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
M&L RCC nomonal mix 1:1.5:3, B1(20 mm graded aggregate) for Columns, pillars, piers, posts and struts complete all as specified.
M&L RCC nomonal mix 1:1.5:3, B1(20 mm graded aggregate) for slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like
M&L RCC nomonal mix 1:1.5:3, B1(20 mm graded aggregate) for Beams,roof beam, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M&L for preparation of new plastered surfaces and applying two coats of Polyurethene(PU) acrylic based water proofing liquid compound over one coat of diluted self priming with reinforcing fabric sheet as per manufacturer instruction to stop leakage/seepage from roof/wall complete all as specified and directed for work in building/structure of any height.
Earth filling under floor spreading and leveling in layers n.exc 25cm thick including welll ramming including watering as required all as specified and as directed.
M&L for 150 mm thick Hard core of gauge n.exc 63mm of branch stone, and leveled in layers n. exc 15 cm thick watered and rammed to true surface all as specified as directed.
M&L for 75 mm thick cement concrete type D2, 1:4:8 (40mm stone aggregate) as in sub base complete all as specified and directed
M & L for Pre-cast cement concrete block masonry, 1:3:6 (20 mm graded ) with solid blocks, exc. 10 cm in width and setting built in CM 1:6 complete all as specified and directed
M&L for cement plaster 1:6 Rendering 10 mm thick on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed
M&L for cement plaster 1:3 Rendering 5mm thick on ceiling complete all as specified and directed
M&L for cement plaster 1:4 rendering 15 mm thick on external surface finished even and smooth (without using extra cement) complete all as specified and directed
M&L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over Screed bed or bedding layer or mortar 15mm CM 1:4 complete all as specified and directed
M&L for glazed ceramic tiles,coloured,350x250x7mm /450x350x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces all as specified and directed.
M & L for preparing of new surfaces, plastered or unplastered and applying three coat of white wash on ceiling complete all as specified and directed.
M & L for preparing of new surfaces, plastered or unplastered and applying two coat of oil emulsion distemper on walls over one coat of alkali resist primer over a 1 mm thick putty complete all as specified and directed
M & L for preparing of new surfaces, plastered or unplastered two coat of cement base paint over one coat of primer on external walls complete all as specified and directed
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm wood grain printed PVC sheet & edges will be painted to match with printed sheet PVC sheet reinforced with M.S. square tube, fixing in opening as per specification and drawing.
S&F factory made solid panel wood grain printed PVC sheet door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable decorative PVC sheet beading 10mm x 10mm (90 Degree) and joined together with solvent cement, and fixing in the frame at site as per specification & drawing.
S&F for 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 complete all as specified and directed
S&F 150 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F aluminium handles, cast type, anodized, of size 100 mm complete all as specified and directed
S&F Aluminium window and ventilator powder coating shutters of any colour ( thickness of powder coating not less than 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-Charge
S&F Powder coated aluminium (minimum thickness of powder coating 50micron) work for doors, windows, louver type ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge complete all as specified and as directed. Note :- S& F of 4mm thick glass & SS wire mesh payment will be made seprately)
M&L 4 mm thick sheet glass, ordinary quality n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F Aluminium anodised powder coating grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge.
Granite (of any type) tiles 18mm to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment tomatch the shade of granite stone including grinding and polishing over 20 mm thick Screed bed or bedding layer for laying floor finishes in CM 1:6 completed all as directed by Engineer-in-Charge
S&F stainless steel soap dish made of stainless steel 1.00mm thick, approximate 150x150 mm fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges.
S&F , EWC vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed complete all as specified and as directed by Engineer-in-Charge
S&F vitreous china wash basin, white, flat back/Angle Back , size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe PVC connection 15 mm size with nuts of length 450 mm.complete all as specified and as directed by Engineer-in-Charge
S&F vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including PVC 'P' trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor as directed by Engineer-in-Charge.
S&F valveless, syphonic action type, low level flushing cistern 10 ltr capacity white, with inlet, ball valve, float including brackets and flush pipe 32mm dia connections to pies pvc connection 450mm long an fixing complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed by Engineer-in-Charge.
S&F stainless steel toilet paper holder fixed to walls with chromium plated (CP) brass screws all as directed by Engr-in-charge
M&L for PVC (SWR) floor trap of oulet dia 75 mm, plain with grating including jointing with solvent cement complete all as specified.
S&F , 15 mm bore stop valve, fancy type, chromium plated with long shank and cup , screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions as directed by Engineer-in-Charge.(Minium weight 15 mm-400 gms)
S&F 15 mm bore bib taps fancy type cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed by Engineer-in-Charge.
S & F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. including urinal spreader 15 mm dia , waste pipe , PVC connection 600 mm long and waste coppling all as specified and directed
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed
M&L for 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete.
S&F PVC (SWR) Vent Cowl 110 mm dia
S&F PVC (SWR) door bends 75 mm dia
S&F PVC (SWR), junction single, (Single T) with acess door 75 mm dia equal or unequal
S&F PVC (SWR), junction single, (Single T) with acess door 110 mm dia equal or unequal
S & F 100 mm Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof all as specified & directed.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 150 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested.
M & L for salt glazed stone ware drain pipes of 150 mm internal dia. Meter grade “A” laid in trenches and jointed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in cills, steps, bands, copings, bed plates, blocks for inserting hold fasts etc. and the like including weathering, slightly rounded or chamfered angles and throating as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered/stopped ends, etc all as specified.
Cutting into existing manholes/SEPTIK TANK for connecting new drains of 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( ½ round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required.
Material & labour for precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab for manhole etc with plane faces complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft /loose soil
Supply and fix mm dia Hand rails, half round or other steel section or core for wooden hand-rail straight portion, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 → drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hipps, roof covering/cladding to wall, fixed with self tapping screws as specified
M & L for Fibre glass reinforced translucent corrugated sheeting , 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc all as specified & directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240 all as specified and directed by Engr-in-Charge
M & L preperation of new steel surfaces of any description, over 10cm in width or girth with two coat synthetic enamel paint over a coat of red oxide complete.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation etc. or for shaft,wells,cesspits,pier holes not exc. 10 sqm area on plan and getting out hard rock complete all as specifed
Excavation in trenches, n exc 1.5m wide and exc 1.5m in depth but n exc 3 m depth for foundation etc. or for shaft,wells,cesspits,pier holes not exc. 10 sqm area on plan and getting out hard rock complete all as specifed
S&F for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binder, cut to length, bent shape required, including cranking , bending, hooking etc and binding with MS wire 0.9mm dia(annealed as directed by Engineer-in-Charge.
M&L for concrete bed to drain including packing under and completely surrounding pipes with concrete after they are laid and tested : in cement concrete 1:3:6 type C-2 bore of pipe in 150 mm complete all as specified and directed by Engineer -in- Charge
M & L for reinforcement pipes of dia 150 mm class NP2, laid and jointed complete with collar all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed by the Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by the Engineer -in-charge.
S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, MS Sheet any thick and similar work conforming to Fe.290.Gde-E-165
Dismantling structural steel work including doors, gates but excluding framed truss etc.
M & L nominal mix 1:2:4 B1 ( using 20mm graded stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M & L nominal mix 1:2:4 B1 ( using 20mm graded stone aggregate) in Columns, pillars, piers, posts and struts
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing ( Fe- 290, Gde E-165) complete all as specified and directed
S & F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
Removing excavated soils to a distance nexc. 50m & depositing where directed a level not exc. 1.5m above the starting point all as specified and directed by Engineer-in-charge.
Surface excavation n exc 30 cm deep and averging 15 cm deep and getting out in Hard rock all as specified nd directed
M & L for 75 mm thick PCC 1 :3:6 Type C-2 (20 mm graded aggregate ) as in floor all as specified and directed
Supply, installation, testing & commissioning of tower AC 4.0 TR capacity, Air conditioner is electric driven, three phase, charged with Eco friendly Refrigerent, comes with special health filter with all connected accessories, including connection of copper piping from indoor to outdoor unit, making of hole in any type of wall, including connection of PVC drain pipe from indoor unit to Outdoor unit, fixing of wall mounted/ floor mounted stand, flexible PVC casing pipe minimum 40mm dia covered on all exposed insulated copper pipe line and PVC wire etc complete all as specified and directed by eng-in-charge. (Note : Cost of copper pipe, wiring, drain pipe shall be measured and paid separately under respective items of this schedule) Make : Voltas/ Carrier Midea/ Blue star or equivalent
Supply only Copper pipe of 5\8'' size for inlet and outlet with nitrile insulation complete all as specified and directed.
Supply only Copper pipe of 3\8'' size for inlet and outlet with nitrile insulation complete all as specified and directed.
Supply only PVC drain pipe flexible type of suitable size as per requirement complete all as specified and directed.
Supply only PVC drain pipe Hard type of suitable size as per requirement complete all as specified and directed.
Supply only of electric cable, XLPE insulated, unarmoured, 1100 volts grade with stranded copper conductor of size 4.0 sqmm 4 core complete all as specified and directed.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 40 to 100 amp.
Supply and fixing single pole neutral Sheet metal enclosure for 08 way DBs when SPN to be used single phase 240 volts, single door complete all as specified and as directed.
S&F TPN sheet metal enclosure, with a three pin and earth plug with socket complete with one TPN MCB 32 amp complete all as specified and directed .
M&L for sub main wiring with 4 runs of 6.0 sqmm single core, PVC insulated & unsheathed (FR) cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed rigid PVC conduit as per ISS and one run of 6.0 sqmm size as earth wire PVC insulated copper conductor complete all as specified and directed.(Note. four run of cable and earth conductor shall be measured as one length) .
One light / fan /exhaust fan point controlled by one switch one way.
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
One 3 pin 5 Amp switch & socket outlet on Independant board.
S&F switch piano, flush type single pole one way 6 Amps 230 volt .
S&F Socket outlet 3 pin, 5A, flush type
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, complete with driver and lamp complete all as specified by Engr-in-Charge.
Supply and fixing in repair metalic body round/ square type shutters suitable for up to 300 mm sweep exhaust fans), colour- Grey, complete all as specified and directed.
Supply and fixing single pole neutral distribution board for 04 way DBs when SPN to be used single phase 240 volts, single door complete all as specified and as directed.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of SPN 40 to 63 amp.
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Supply and Fixing of XLPE insulated ,Armoured heavy duty electric cable with aluminium conductor ,1100 volts grade , cross sectional area 10 Sqmm
One light / fan point controlled by one switch one way.
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
S&F switch modular single pole one way 6 Amps 230 volt 1 module.
S&F Socket modular 6 Amp 2/3 pin combined two module.
S&F Ceiling rose moduler surface bakelite 65x50mm three terminal.
Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 20 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.
Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 9/10 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.
S&F LED light fitting 1 x 10W bulkhead luminaires including inbuild LED light driver perfect interior and exterier application connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F Exhaust fan 250 mm sweep, made of sturdy engineering plastic, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified.
Supply and fixing wall mounted fans complete with blades and accessories, 230 V , 400mm sweep including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including making of MES number and fixed in position as recommended by manufacturer complete all as specification.
Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connecting with galvanizing iron & steel GI earth wire 4 mm dia by means of bolt nut check nuts and washers of galvanised iron, 15 mm dia GI Pipe for protection to earth lead including PCC with 1:2:4 type B1 using 20mm graded stone aggregate CI frame and cover of angle iron 25 X 25 X 3 mm with 6 mm dia MS bar made to shape GI medium 20 mm bore pipe for watering in any type of soil returning filling in and removal of surplus soil to a distance n.exc 5.0 mm all as per electric plate no.3OF SSR 2009 Part I connected to earth test point all as specified and indicated including testing on completion.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of SPN 32 amp.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core
Savitri Enterprises (BID ID -3496647)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tender_8555.pdf
Tender Documents • 3.50 MB
BOQ_828665.xls
BOQ • 0.80 MB
Download all tender documents and submit your bid