| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹44.0 L+₹8.5 L (24.1%)Rejected-AOC DOOR NO 18 13 3 3RD FLOOR HILL CREST APARTMENTS SEETHAMMADHARA NORTH EXTENSION VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹45.9 L+₹10.4 L (29.5%)Rejected-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | NTR | ANDHRA PRADESH | 520001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹48.2 L+₹12.8 L (36.0%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹48.3 L+₹12.9 L (36.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | pavan putra enterprises L9 | NEELESH ENTERPRISES L8 | M/s Sai Venkata Durga Constructions L5 | HARISH CONSTRUCTION L2 | RATNA ENTERPRISES L1 | venkata sai constructions L7 | sai ganesh enterprises L3 | SRK PROFESSIONAL ENGINEERING L6 | K NAGARAJU L4 | N V S S K N SIVA PRASAD L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: B/R WORKS | |||||||||||||
| 1.00 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth and getting out in soft/ loose soil. | 61 | Cum | 180 ₹10,980 | 805 ₹49,105 | 275 ₹16,775 | 90 ₹5,490 Lowest | 250 ₹15,250 | 805 ₹49,105 | 800 ₹48,800 | 810 ₹49,410 | 350 ₹21,350 | 400 ₹24,400 |
| 2.00 | M&L for plain cement concrete (1:4:8), type D2 (using 40mm graded stone aggregate) as in foundation, filling of mass concrete. | 5.4 | Cum | 4,600 ₹24,840 | 4,820 ₹26,028 | 3,500 ₹18,900 Lowest | 5,400 ₹29,160 | 4,500 ₹24,300 | 4,855 ₹26,217 | 4,800 ₹25,920 | 4,850 ₹26,190 | 5,000 ₹27,000 | 4,000 ₹21,600 |
| 3.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils. | 19 | Cum | 200 ₹3,800 | 292 ₹5,548 | 75 ₹1,425 Lowest | 180 ₹3,420 | 100 ₹1,900 | 300 ₹5,700 | 300 ₹5,700 | 295 ₹5,605 | 120 ₹2,280 | 200 ₹3,800 |
| 4.00 | Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point. | 43 | Cum | 200 ₹8,600 | 515 ₹22,145 | 260 ₹11,180 | 270 ₹11,610 | 150 ₹6,450 Lowest | 400 ₹17,200 | 400 ₹17,200 | 410 ₹17,630 | 360 ₹15,480 | 500 ₹21,500 |
| 5.00 | Moorum/sand filling in floors laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering to required level and gradient. | 35 | Cum | 200 ₹7,000 Lowest | 1,160 ₹40,600 | 1,250 ₹43,750 | 1,800 ₹63,000 | 1,600 ₹56,000 | 1,100 ₹38,500 | 1,200 ₹42,000 | 1,150 ₹40,250 | 1,500 ₹52,500 | 1,800 ₹63,000 |
| 6.00 | M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders | 10.5 | Cum | 380 ₹3,990 Lowest | 1,430 ₹15,015 | 1,400 ₹14,700 | 1,800 ₹18,900 | 4,000 ₹42,000 | 1,450 ₹15,225 | 1,450 ₹15,225 | 1,425 ₹14,962.5 | 1,200 ₹12,600 | 1,900 ₹19,950 |
| 7.00 | M&L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring | 69.5 | Sqm | 280 ₹19,460 Lowest | 362 ₹25,159 | 365 ₹25,367.5 | 450 ₹31,275 | 300 ₹20,850 | 350 ₹24,325 | 350 ₹24,325 | 360 ₹25,020 | 450 ₹31,275 | 500 ₹34,750 |
| 8.00 | M&L for cement concrete 40mm thick type B-1 ( 20mm graded aggregate) as in floor surface finishing even and smooth with using extra cement. | 69.5 | Sqm | 250 ₹17,375 | 262 ₹18,209 | 225 ₹15,637.5 | 540 ₹37,530 | 230 ₹15,985 | 250 ₹17,375 | 250 ₹17,375 | 260 ₹18,070 | 200 ₹13,900 Lowest | 300 ₹20,850 |
| 9.00 | Supply only Integral water proofing compound | 80 | Kg | 450 ₹36,000 | 62 ₹4,960 | 45 ₹3,600 | 45 ₹3,600 | 40 ₹3,200 Lowest | 50 ₹4,000 | 65 ₹5,200 | 60 ₹4,800 | 80 ₹6,400 | 300 ₹24,000 |
Tender Value
₹43.8 L
EMD Value
₹87,500
Closing Date
13 Dec 2025, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVISION OF ATTACHED TOILET FOR LMO 02 03 ROOMS VACCINATION ROOM DRIVERS REST ROOM AND AMBULANCE PARKING SHED AT BUILDING NO P54 MI ROOM SVN COLONY 104 AREA VISAKHAPATNAM
2025_MES_741055_1
8535/GEND/E8
Open Tender
Civil Works
Works
180 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹87,500
Yes
19 Feb 2026
21 Nov 2025
15 Dec 2025
21 Nov 2025
13 Dec 2025
6 Dec 2025
Amount
SCHEDULE 'A' PART-I: B/R WORKS
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth and getting out in soft/ loose soil.
M&L for plain cement concrete (1:4:8), type D2 (using 40mm graded stone aggregate) as in foundation, filling of mass concrete.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point.
Moorum/sand filling in floors laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering to required level and gradient.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders
M&L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring
M&L for cement concrete 40mm thick type B-1 ( 20mm graded aggregate) as in floor surface finishing even and smooth with using extra cement.
Supply only Integral water proofing compound
Demolition of brickwork built in cement mortor including all quoins arches, pillars etc complete & removal as specified.
M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6
All as Per item No. 11 above but half brick CM 1:4
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finishing the surface fair and even.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finishing the surface fair and even using WPC as on external surface all as directed.
M&L fo Rendering 5 mm thick on fair faces of concrete surfaces in cement mortar 1:3 and finished even and smooth without using extra cement
M & L for preparation of new internal plastered wall surfaces and applying two coats of oil emulsion distemper over a coat of primer after finishing wall surfaces with JK/Birla wall care putty n.exc 3mm thick to get a smooth finish all as specified and as directed.
Material & Labour for preparation of new external plastered wall /ceiling surfaces applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces
M & L for preparing newly plastered surfaces of walls and applying three coats of white wash on ceiling
M & L for reinforced cement concrete M-30 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete.
M & L for reinforced cement concrete M-30(using 20 mm graded stone aggregate) in beams, cantilevers, lintels over 1.5 m span.
M & L for reinforced cement concrete M-30 (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc.
M & L for reinforced cement concrete M-30 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, chajjas, landings, balconies, canopies, deck slabs and in shelves etc.
M & L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter.
M & L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves, including supports, overhangs, etc, also splays between floors and beams etc.
M & L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings, Chajja and similar work, not exceeding 200mm thick (Horizontal or sloping).
M & L for Mild steel TMT bars upto 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
M&L for Vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36sqm, as in floors etc set & jointed in neat cement slurry & pointed in white or dark coloured cement to match including screed bed of 15mm thick in CM 1:6 complete all as specified and as directed.
M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding. 0.18 sqm on vertical surfaces for skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in cement mortar (1:4) for backing of tiles.
M & L for Coloured Glazed ceramic tiles 300 x 450 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 10 mm thick rendering in cement morter (1:4)
M & L for preparation of new wood surfaces of any descrition, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
M & L for preparation of new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide priming.
S&F of 2nd class HW plain chowkhats and framed, rebated on the solid rounded or chamfered lput together with glue pinned at joints all as specified and directed by Engr-in-Charge
M&L for plain cement concrete type C1, (1:3:6) (using 20mm graded stone aggregate) cast in situ in cills and other similar bands, plinth courses, parapets, copings, hold fast, bed plated and the like including use and waste of form work, weathering, slightly rounded or chamfered angles and throating as required.
S&F mild steel hold fast made out of MS flat iron 40x6mm thick for chowkats and other small articles including making shape, drilling holes etc.
S&F 35mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides.
S&F butt hinges, medium weight 100mm long cold rolled mild steel upto 2nd floor
S&F 200mm aluminium anodised barrel tower bolts of stove enameled black, with bright bolt and fixed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp and staple, (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer?in-charg upt 10th storey
S&F Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc
Excavation in post hole(or similar holes) each n.exc 0.50 Cum getting out returning filling in and ramming earth around in layers n.exc 25cm watering and removed surplus soil to a distance n.exc 50m and making good surface in soft/loose soil.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
M & L for 0.50mm thick prepainted galvalume aluminium zinc coating G.I. based corrugated steel sheet of on colour having tensile strength of 550MPa as in roof covering, fixed with and including self tapping screw complete all as per manufacturer instructions (Make : DYNA ROOF / TATA).
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions
S&F anodised aluminium snap grid 605x605mm frame work for false ceiling all as specified
Taking down shutters of any description exc 1sqm but n.exc 2 sqm each and refixing in same opening
Taking down shutters of any description exc 2 sqm each and refixing in same opening
Taking down cement plaster on brick work, racking out joints, hacking for key scrubbing down with water etc complete and removing outside MD land .
M&L for rendering 5mm thick in CM 1:3 on fair faces of ceiling surfaces finished even & smooth without using extra cement complete all as directed
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the top surface even and smooth without using extra cement with necessary safety measures i.e.scaffoldings/hanging platform complete all as directed
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M&L for Preparing newly Plastered surfaces of ceiling and applying two coats of white wash, complete all as specified and directed
M&L for Preparing newly Plastered surfaces of walls and applying two coats of distemper oil emulsion (Oil bound washable distemper) over a Coat of chalk whitening complete all as specified and directed.
Material & Labour for preparation of new external plastered wall /ceiling surfaces applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces
Complete removal of existing treatment over wall surfaces applying including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over n.exc 3mm thick wall care putty complete all as specified and as directed.
Complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
S&F rotational moulded polyethylene water storage tanks (cyclindrical vertical with closed top) hoisted and fixed in position all as 1000 Litres
S&F 20mm ball brass valves,high pressure,with polythane float and flynut complete,screwed for iron pipe or brass ferrule .
S&Fof 15 mm stop valve cromium plated ,long shank & cup screwd down,high pressure,with crutch or butterfly, handle,screwd both end for iron pipe or for unions and fix.
S&F for pillar taps, cast copper alloy with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore. ( Make:Jaquar or equivalent).
S&F of 20 mm stop valve cromium plated ,long shank & cup screwd down,high pressure,with crutch or butterfly, handle,screwd both end for iron pipe or for unions and fix.
S&F 3-layer PP-R Polypropylene random copolymer)pipes 15 mm dia PN1.6 SDR 7.4 & SDR 11 UV stablised laid & concealed in walls including bends, elbows, unions etc, laid on walls for vertical stacks including chasing the wall and making good complete all as specified and as directed.
All as per item No. 65 above but 20 mm dia
S&F solid PVC door frame of size 50mm & 47 mm made out of 5mm plain colour PVC sheet reinforce with MS square tube supply & fixing in opening as per specification & drawing
S&F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with 2,4,6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supply and fixing in frame at site as per specification & drawing
S&F 75 mm size stainless steel butt hinges ,bright finished .
S&F 125mm AL anodised cast type handle,.
S&F 150mm AL anodised extruded barrel tower bolts with bright bolt .
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls,75 mm bore.
S&F PVC (SWR) vent cowl,75 mm bore
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent including proper bedding and jointing with existing pipe
S&F 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.
S&F Vitreous China Urinal, Half stall type, white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S & F Vitreous China wash down water closet pan (Pedestal pattern), white (ETWC) with ‘P’ or ‘S’ trap, white including connection to drain or outgoing pipe and to PVC flushing pipe, antisyphonage pipe,10 litres capacity PVC flushing cistern low level , valve less, symphonic action type complete with inlet ball valve, float and handle with brackets and plastic water closet seat cover, white, closed pattern with recessed bottom cover and mild steel chromium plated hinge all as specified and directed.
S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect all as specified Floor
S&F wash hand basin vitreous china white (flat back) of size 550x400mm including , CI bracket, 15mm dia polythene connection , 32mm dia chromium plated (CP) waste coupling chain and plug waste filling union and 32mm dia PVC waste pipe 90cm long etc. complete all as specified, and all necessary inlet outlet connections complete all as specified and directed.
S&FSheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long
S&F chromium plated 20 mm dia tubular Towel Rail of 600 mm long including brackets and CP screws and fixing to wall complete .
S&F for Bib taps fancy type cast copper alloy, chromium plated for 15 mm bore pipe, screwed for iron pipes or for brass ferrule all complete as specified and as dierected.
S&F in repairs Brass chromium plated mixer 15 mm bore for hot & cold water screwed down for iron pipe fixed in repairs complete all as specified and directed.
Brushing neat cement slurry with 3 kg of cement per square metre .
Rendering 10 mm thick on concrete surfaces in cement mortar 1:4 mixed with WPC as directed and finished even and smooth to receive water proof treatment above 8 th storey upto 2nd floor complete all as specified and directed [NOTE: Supply only WPC shall be measured and paid separately]
S&F of APP based polymeric water proofing membrane priming the surface with a coat of cold applied bituminous primer " 0.50Kg/Sqm, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg/Sqm, lying Polymeric water proofing membrane of weight not less than 150 Grams per Sqm by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 " 1.2 Kg/Sqm complete all as specifed and as directed.
S&F cement concrete tiles 250x250x22 mm thick machine pressed jointed and pointed in neat cement slurry in floors with grey cement and no pigments incl screed 15mm thick in CM 1:6 complte all as specified and as directed.
M & L for along the external wall below concrete or masonry spron using chemecal emulsion @ 2.25 ltrs per liners metre incl drilling and plugging holes etc in apron
M & L treatment of soil under existing floors using emulsion @ one lts per hole 300mm apart incl drilling and plugging 12mm dia holes with cement mortor 1:2 (1cement : 2sand) to match the existing floors
M & L at points of contact to wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5ltr/hole by drilling 6mm dia holes at a downward angle of 45 degree at 1.5mm centre to centre and sealing the same from ground floor to 3rd floor.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer in Charge.
M&L cement concrete type C1 ,1:3:6 ( using 20 mm graded stone aggregate) 75mm thick as in plinth protection,path etc finished the surface even and fair w/o using extra cement complete all as specified and directed.
M&L for 15 mm thick screed bed in CM(1:6) set jointed in neat cement slurry and pointed with colour cement to match the tiles complete.
M & L for precasted PCC Chequared tiles prepolished machine pressed chemically treated for antifurgal 300 X 300mm size X 25 mm thick of approved coloured complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, set and jointed in CM (1:4) with grey cement and pigment including 30mm thick sand filling complete all as specified and as directed.
M&L for precast RCC (1:2:4) type B1 using 20mm graded aggregate as in cover slabs/ shelves set in CM1:4 including necessary form work.
M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief.
Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
M&L for 12mm thick prelaminated particle board, interior grade prelaminated both side with decorative choice lamination fixed with frame all as specified and directed.
S&F plain glass 5.5mm thick ordinary quality glazing with oil putty in squares each pane exc 0.50 sqm fixed with glazing clips complete all as specified
S&F aluminium extruded section body door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed ®
S&F 150mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls
PVC (SWR) bends any 110mm bore
S&F Vitreous China Ladies urinal of minimum size 430x350x100mm white with grating and union for discharge pipe complete.
S/F PP-R Gate valves (brass insert) of 20mm dia with iron wheel head screwed both ends for iron pipe and fixed etc .
SCHEDULE 'A' PART-II: E/M WORKS
M & L For Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through PVC Conduit concealed in Walls / Roofs / Floors / Ceiling etc. and Modular Type Pressed Metal Flush Box made out of 1mm thick GI Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell point controlled by One Switch complete all as specified. [Note- The PVC Conduit to Concealed in wall through cutting,Chassing,Pining in making good surfacing where required and pointing in cement mortar and making good for same unit rates are inculded for same]
Description all as per item No. 1 above but for 5 / 6 Amps switch socket out let, independent board complete all as specified
Description all as per item No. 1 above but for 15/16Amp switch socket out let, independent with 4.0sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, including taking down old point wiring, complete all as specified
Supply and fixing Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
Supply and fixing of Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.
Supply and fixing of Socket 6A/16A - 2/3 pin combined 2 module, 230 volt,multipurpose, complete all as specified.
Supply and fixing Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge.
Supply and fix modular electronic fan regulator, socket type, 2 module 120 Watt.
Supply and fixing ceiling rose surface bake lite with 3 terminals complete all as specified and directed by Engr-in-charge.
S & F bell push modular, one way 6 Amps, 1 module 230V complete all as specified and directed.
S & F in repairs of calling bell AC 230V,complete as specified by Engg-in-Charge
Supply and fixing LED lights fitting 18W / 20W, 220V, AC decorative box type with driver including LED tube light batten fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete complete all as specfied and directed
Supply and fixing LED lights fitting 9W / 10W, 220V, AC with driver including LED tube light batten fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete complete all as specfied and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repairs Building Security light LED type of minimum 3500 Lumens (35 Watt) Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair Square recessed mounted LED light (2'x2') of minimum 3600 Lumens (36W) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repairs LED CIrcular lights fitting 12W, 220V, Ceiling cutout: Ø 160 mm, height 16 mm, with driver including LED round light fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete complete all as specfied and directed
Supply and fixing in repairs LED Dome lights fitting 7W, 220V, AC with driver including LED tube light batten fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete complete all as specfied and directed
Supply and fixing Ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix Exhaust fan, heavy duty, steel body AC single Phase. 230V of size 300mm sweep with blades, frame and louvers including making suitable hole for fixing Exhaust fan and making good to disturbed surface, matching with existing paint complete all as specified and directed.
Supply and fixing in repairs of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 12 Way, IP-42 protection with 100 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , including taking down old unserviceable DB of any type/make and making good and matching with existing surface complete all as specified.
Supply and fixing of Factory made sheet metal enclosure for VTPN DB 4 way (Fixed flush to the wall), with provision of MCCB 100 Amps,16 KA, 415 volt, IP-43 protection with 200 Amp rated bus bar and 6.0 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified.
Supply and fixing in repairs of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 100 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , including taking down old unserviceable DB of any type/make and making good and matching with existing surface complete all as specified.
Supply and fixing in repair of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified
Supply and fixing in repair of MCB 40 to 63 Amp, 415 Volt, TP/TPN, breaking capacity 10 KA 'C' series, complete all as specified
Supply and fixing in repair of MCB 32 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, complete all as specified
Taking down existing ceiling fan / exhaust fan of any size, sweep and make from its position and doing complete overhauling of fan including replacement of fan clamp , split pin, rubber bush, fan capacitor of 2.5mfd, bearings and Rewinding of ceiling fan motor with super enameled copper wire of appropriate gauge and other spares including painting with synthetic enamel paint over a paint of primer refixing the same after repairs complete all as directed by Engr-in-Charge. .
S & F Modular Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20A rating complete all as specified and as directed.
M&L for sub main wiring 2 runs of 4 sqmm PVC insulated unsheathed copper cable 1100V grade FRLS single core drawn in and including non metallic rigid PVC concealed conduit not less than 20mm dia including all specials and 4.0 sqmm PVC insulated copper conductor for earth continuity conductor including taking down old unserviceable sub main wiring of any size and make, complete all as specified and directed. (NOTE :- 3 run of 4 sqmm and one run of concealed conduit will be measured as one length i.e RM.)
M&L for sub main wiring 2 runs of 6.0 sqmm PVC insulated unsheathed copper cable 1100V grade FRLS single core drawn in and including non metallic rigid PVC concealed conduit not less than 25mm dia including all specials and 6.00sqmm PVC insulated copper conductor for earth continuity conductor including taking down old unserviceable sub main wiring of any size and make, complete all as specified and directed. (NOTE :- 3 run of 6.0 sqmm and one run of concealed conduit will be measured as one length i.e RM.)
M&L for sub main wiring 4 runs of 10.0 sqmm PVC insulated unsheathed copper cable 1100V grade FRLS single core drawn in and including non metallic rigid PVC concealed conduit not less than 25mm dia including all specials and one run 10.0 sqmm PVC insulated copper conductor for earth continuity conductor including taking down old unserviceable sub main wiring of any size and make, complete all as specified and directed. (NOTE :- 5 run of 10.0 sqmm and one run of concealed conduit will be measured as one length i.e RM.)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core, including taking down old unsv XLPE cable of any size and make, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4 core, including taking down old unsv XLPE cable of any size and make, complete all as specified and directed.
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply and laying in trenches bricks common burnt clay building brick , sub class B designation 75 complete all as specified & directed.
Material and labour for 40 mm dia GI steel tubes 'light grade' for cable protection including sealing both ends complete all as specified and as directed by Engineer-in-charge
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including taking down old perished earthing complete all as specified and directed.
Labour for Taking down ACs of any type (Split/Window) any capacity 2.0/1.5) indoor/outdoor unit complete after disconnecting from supply mains and restoring the refrigerent gas and sealing the copper pipe line, servicing of AC with electrical blower and motor, cleaning with castic soda and soap water to all the parts including evaporator, condenser, grills, etc and checking of all the electrical connections, including replacing of copper pipes of suitable size including insulation complete all as specified and directed by Engineer in Charge and refixing the same after necessaary concreat and painting work on walls complete all as specified. Note -(i) It is the responsibility of the contractor to keep the AC units in safe custody during the exicution of work. (ii) Any damaged to existing AC units done during taking down and refixing process has to be beared by the contractor on its own cost and no extra cost is given for this.
HARISH CONSTRUCTION (BID ID -3497092)
sai ganesh enterprises (BID ID -3495771)
K NAGARAJU (BID ID -3495710)
M/s Sai Venkata Durga Constructions (BID ID -3496653)
SRK PROFESSIONAL ENGINEERING (BID ID -3495847)
venkata sai constructions (BID ID -3497229)
NEELESH ENTERPRISES (BID ID -3495843)
pavan putra enterprises (BID ID -3495594)
N V S S K N SIVA PRASAD (BID ID -3496433)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TENDER8535.pdf
Tender Documents • 4.18 MB
BOQ_829803.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .