Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹10.0 L+₹21,525 (2.21%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹15.5 L+₹5.7 L (58.7%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹20.4 L+₹10.6 L (108.6%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
4 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Chandigarh
GE Chandigarh
REPAIR AND MAINTENANCE OF VARIOUS SUMMER AND WINTER APPLIANCES AT K AREA AND SEC 28/29 UNDER GE CHANDIGARH.
2021_MES_433998_1
GE/CHD-02/2021-22
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
class E Cat b i
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹40,000
Yes
7 Jun 2021
1 Apr 2021
6 May 2021
1 Apr 2021
4 May 2021
22 Apr 2021
1 Apr 2021 - 6 Apr 2021
60 days
Amount
Taking down Ceiling fan of Sweep, any make, 1200/1400/1500mm, 230 volts of any make & size from any height of the building for finding out the defects such as Capacitor, winding, bearing etc and servicing / overhauling the same, including replacing minor accessories like locking pins, rubber real, PVC sleeve, greasing, clamps, etc as required, and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge. Note:- The spares referred / mentioned here-In- after shall only be paid under supply only. Rest of the spares required for functioning of the fans is deemed to be included in the unit rate quoted. The labour element required for replacing the spares listed here-In -after shall be deemed to included in the unit rate quoted.
Taking down Exhaust fans heavy duty of Sweep 225 to 450mm, 230 volts of any make & size from walls/ trusts for finding out the defects such as Capacitor, winding, bearing etc and servicing/ overhauling the same and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge. Note:- The spares referred / mentioned here-In- after shall only be paid under supply only. Rest of the spares required for functioning of the fans is deemed to be included in the unit rate quoted. The labour element required for replacing the spares listed here-In -after shall be deemed to included in the unit rate quoted.
Taking down Wall mounted/Pedestal fans of Sweep 300 to 450mm, 230 volts of any make & size from walls/floors for finding out the defects such as Capacitor, winding, bearing etc and servicing/ overhauling the same and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer in charge.. Note for Item Sl No 1 to 3 : (i). Cost of Bearing, Capacitor and rewinding will be measured and paid separately under the respective item of the Schedule. (ii) Labour element for removing and refixing the Bearing and removing and rewinding the winding will be measured in the respective of the schedule. (iii) Misc items such as nut & bolts, Rubber bush & locking pin etc required for satisfactory completion of job deemed to be inclusive of the unit rate.
Rewinding of fan motor of any make Sweep 1200 and rewinding the same with single strand fine enamel copper conductor of same guage weight and turns and keeping the windings into hot air oven till the moisture evaporates including testing and commissioning complete. Make :Devi Dayal/Atlas/BPL Note : (1) All the misc items such as impregranted paper, warnising, cotton tape and other misc items required for satisfactory completion of job deemed to be included in the unit rate. (2) The above repairs are considered to meet the anticipated requirement if any and based on the site requirement the scope will be handed over to the Contractor.
All as item No 04 here in above but for Ceiling fan1400/1500mm sweep.
All as item No 04 here in above but for Exhaust fan 225 to 300mm sweep.
All as item No 04 here in above but for Exhaust fan 350 t0 450mm sweep.
All as item No 04 here in above but for Pedestal / Wall mounted fan upto 450mm sweep.
S&f of Capacitor 2.5/3.15 MFD, AC 250 volts capacity all as directed. Make :Usha / Bajaj / Tibco / CG
Supply only Ball bearing suitable for 1200/1400/1500 mm sweep ceiling fans. Make: NBC/Tata
S&f in repair M.S rod including clamp, nut & split pin suitable for 1200/1400mm sweep fan complete all as specified and as directed by Engineer-in-charge.
S&f in repair PVC canopy suitable for 1200/1400/1500mm sweep fan complete all as specified and as directed by Engineer-in-charge.
S&f in repair fan blades (set of three blades) for 1200/1400 mm sweep ceiling fans complete all as specified and as directed by Engineer-in-charge.
Supply only gun metal bush suitable for 1200/1400/1500 mm sweep ceiling fans
Supply only Mild steel shaft suitable for 1200/1400/1500 mm sweep ceiling fans
Supply only Rubber real for ceiling fan any type any description.
Preparation of surface and painting the Ceiling fan unit of sweep 1200/1400/1500mm (consisting of Fan motor, blades, canopy and downrod) with one coat of synthetic enamel paint of existing colour and marking the MES number on the fan motor with suitable paints all as directed by the Eng-in-Charge complete. Make :- Asian / Berger / Johnson.
Disconnecting and removing the U/S Ceiling/fan and S&f in repair AC ceiling fan 1200 mm (BLDC) sweep with Accessires Complate with set of lades, down rod and set of canopy. Make :Usha/Crompton/Havells.
Supply only Ball bearing suitable for 225 to 450 mm sweep Exhaust / Wall mounting fan/Pedestal fan.Make: NBC/Tata
Supply only gun metal bush suitable for 225mm to 450 mm sweep Exhaust / Wall mounting fan
Supply only Mild steel shaft suitable for 225mm to 450 mm sweep Exhaust / Wall mounting fan
S&f in repair fan blades (set of one blades) for 300 to 450mm Exhaust fan complete all as specified and as directed by Engineer-in-charge.
S&f of Capacitor 4/4.5 MFD, AC 250 volts Make :- Usha / Bajaj / Tibco / CG
M&L for lathe work to any type of fan for taking out bush from the lower body part of Ceiling/Exhaust fan and replacing it with suitable size of ball bearing as per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft Complete all as specified and as directed by Engineer-in-charge. Note : - Supply & fixing to Bearing shall be measured and paid separately under respective item of this Schedule.
Disconnecting and removing the U/S exhaust fan and S&f in repair Exhaust fan 250 mm/300mm sweep high air delivery low noise complete with diffusers Make : USHA/Crompton/Havells.
Disconnecting and removing the unserviceable Geyser electrically operated of capacity 25 to 50 Capacity from its original position including disconnecting the electrical and water connections and to finding out the defects and refixing the same after making the same in serviceable condition in its original position connecting up of Electric and water connections, testing and commissioning complete all as specified and directed by Engg-in-Charge. Note : (i) Spare parts such as Inner copper container, thermostat, element, hot & cold water inter connected pipes and cord flexible will be measured and paid separatley. (ii) Misc items and brazing to the Inner copper container and welding to the outer container as required for satisfactory completion of Job deemed to be included in the unit quoted rate. (iii) Existing glass wool to be used after repairs.
S&F thermostat for Geyser 0 to 80 degrees capacity 230 volts as suits the existing geyser of any type and capacity all as specified and directed by Engg-in-Charge. Make :- Bajaj / Racold / Veenus / usha
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 28 here-in-before but 50 litre capacity.
Disconnecting and removing the unserviceable Supply and fix in repairs Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembled & fixed at site complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 30 here-in-before but 50 ltr capacity.
Supply and fix in repairs Heating element 2 KW ISI Marked complate all as specified and as directed. MAKE:-RECOLD / VENUS / GILCO / PREMIER / THEETA
Supply and fix in repairs Heating element 2/3 KW triangle shape complate all as specified and as directed. MAKE:-Recold/ Venus /Crompton
Supply and fix in repairs 06/08 hole Assembly for water heateer ISI Marked complate all as specified and as directed. MAKE:-Crompton/Havells/ Venus.
Supply and fix in repairs Safety valve
Supply and fix in repairs Indicating Lamp Round /Square
Supply and fix in repairs 23 to 30 cm long, C.P Connection with brass union
Supply and fix in repairs Gun metal non return valve ,15 mm bore
S&F PVC connection 450mm long for cold / hot water heavy duty PK Aqua made out of double layer at Nylon & wire fabric at pressure 6Kg / CM both side, CP brass 15mm bore coupling or nuts.
S&F in repairs Apparatus plate for 25 litre / Syphon Assy
S&F in repairs Apparatus plate for 50 litre / Syphon Assy
S&F in repairs Bottom plates in two holes for 25/50 liter.
S&F in repairs Plug top 3-pin, 16 Amp
S&F in repairs Rubber 'O' ring /gaskit for 25 ltrs
Disconnecting and removing the unserviceable & Supply and fix in repairs Electric water storage Heater (vertical type Geysers) 25 Ltrs 230 volts, AC single phase with and including grouting with high tensile rag bolt, nut & washer etc as directed as per site requirement .Geysers to have glass lines tank, fero glass coated container,PUF insulation, glass coated heating element, 8 BAR rated pressurer, thermostat cut off etc.including cutting holes and making good the disturbed surface complete all as specified and as directed by Engineer in charge. Make : Havells/Venus/Bajaj
M&L for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying two coats of synthetic enamel paint over a coat of red oxide primer and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying two coats of synthetic enamel paint over a coat of red oxide primer and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
S&F for replacement to unserviceable flexible PVC insulated lead in lieu of provided with new flexible PVC insulated sheathed copper conductor connection lead 3-core ,size 40/0.0076 cable suitable for Geyser Complete all as specified and as directed by Engineer-in-Charge. MAKE :- Havells / finolex/Palaza/RR Kable
Cutting chasing in bricks/walls or concrete surfaces for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge
S&F for sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt including MCB SP,20Amp as in repair complete all as specified and as directed by Engineer-in-Charge. Make :- Indoasian / Havells/ Legrand
S&F for 15mm bore stop valve cast copper alloy chromium plated fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge. Make :Kiran/Leader/Prayag
S&F for 20mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.Make :KIRAN/LEADER/PRAYAG
Taking down to 15mm bore steel tubing and connection including cleaning for re-fixing or remove from site complete all as directed by Engineer-in-Charge.
Disconnecting and removing the unserviceable GI Tubing and S&F for 15mm bore steel water tubing medium grade, galvanised with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors complete all as specified and directed by Engineer-in-charge. Make - Jindal/Suryaparkash/tata
All as per item No 54 here in above but of 20mm bore
Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm dia, IN REPAIRS, complete all as specified. MAKE: SANT,BIR, ZOLOTA,
Arresting of water leakage from existing pipe line in position from GI pipe of size 15/20mm bore, including wall/roof through Men/Mechnical power, cutting threading as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified.
Disconnecting and removing the unserviceable sealed compressor of water cooler of capacity 150/180liters and replaceed with new sealed compressor of existing capacity & model including soldering of liquid/gas pipe cleaning the system arresting the leaking etc complete all as specified and as directed by Engineer-in Charge. Make: Sri Ram/Tikamshah/Kirlosker. NOTE:- Recharging of refrigerant gas shall be measured & paid separately under respective item of this schedule 'A'.
All as per above item No 58 here in before but water cooler of capacity 40/80Liters.
Cleaning the system with CTC and charging the refrigerant gas R-22/134 including replacing strainer and rectification of leakage of the system from water cooler of 150 litres capacity complete all as specified and as directed by Engineer-in-charge.
All as per above item No 60 here in before but water cooler of capacity 40/80 liters
S&F for internal wiring for water coolers 150/80/40 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.Make :-- Kalinga/Finolex/Palaza.
Supply and fix in repairs starting relay assembly suitable for water cooler of 150 liter capacity Complete all as specified and as directed by Engineer-in-Charge . Make :Indfos/Danfos
All as per above item No 63 hereinbefore but water cooler of capacity 40/80 liter
Supply and fix in repairs over load protector suitable for water cooler of 150 liter capacity Complete all as specified and as directed by Engineer-in-Charge. Make :- Renutral/ Indfos
All as per above item No 65 hereinbefore but water cooler of capacity 40/80 liter
S&F in repair fan motor suitable for water cooler of 150 liter capacity Complete all as specified and as directed by Engineer-in-Charge. Make :- COOL-HOME/ AUE
All as per above item No 67 hereinbefore but water cooler of capacity 40/80 liter
Replacement to unserviceable Condenser unit with new condenser unit of existing make and model suitable for water cooler of capacity 150/180 liters, complate all as specified and as directed.
All as per above item No 69 here in before but water cooler of capacity 40/80Liters.
S& F for 15 mm bore self closing tap push type cast copper alloy chromium plated fixed to water cooler as in repair Complete all as specified and as directed by Engineer-in-Charge.
Disconnection and removing the unserviceable Ball valve of PVC high pressure with polythene float & flynut and S&F Ball valve of PVC high pressure with polythene float & flynut of 15 mm dia and capacity suitable for 40 to 150 Ltrs Water Cooler as per sample .
M&L for Cleaning to water coolers upto 150 ltrs capacity internal & external surfaces of suitable repairs to body & stop leakage etc, replacing unserviceable nut bolts & washers etc including preparation of external surfaces of bottom body and painted with anticorrosive synthetic enamel paint with help of spray gun machine over a coat of red oxide primer Complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 73 hereinbefore but water cooler of capacity 40/80 liter
S&F for replacement to unserviceable thermo-state switch in lieu of provided with new thermo-state switch suitable for water cooler any capacity Complete all as specified and as directed by Engineer-in-Charge. Make :- RENUTRAL/ INDFOS/BAJAJ
Disconnecting and removing the u/s and Supply fixing incl testing in repairs of Pure-R Refrigerator single phase electric driven of (500 watt) water dispenser complete all as specified and as directed by Engineer-in-Charge. Make: Voltas/blue star
Supply and fix in repairs sealed compressor for refrigerator of capacity 165/315 liter of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & the leakage etc complete all as specified and as directed by Engineer-in-charge. Make :- SHRI-RAM/ TIKAMSHAH/ KIRLOSKER / WHIRLPOOL .
Recharging of Gas R-10/12/134a in refrigerant Cap 180/210 litre complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Freezer door plastic with tension spring as per existing model suitable 160/210 liter cap.
S&F in repairs Door liner ( Plastic ) for upto 310 liter capacity
S&F in repairs Door magnetic gaskest for upto 310 litre cap.
S&F in repairs Relay box type for any cap.
S&F in repairs over load protector for any Cap.
S&F Bulb Unit of same size and capacity suitable for 165 to 315 ltrs refrigerator
S&F Fan Motor of same size and capacity suitable for 165 to 315 ltrs refrigerator
S&F Over Load Protector Unit of same size and capacity suitable for 165 to 315 ltrs refrigerator
Opening to refrigerator frezzer of capacity 180 to 320ltr Refixing the same after flushing out and removal of blockge brazing replacement of liquid line, filter and recharging to refrigerator with F-22/134a gas to obtain the desired cooling complete all as specified and as directed by engineer-in-charge
Opening to refrigerator PCB Circuit plate of capacity 180 to 308ltr and S&F PCB Circuit plate fixing the same size (as per site require) Complete all as specified and as directed by engineer-in-charge
Supply fixing incl testing in repairs of Refrigerator single phase electric driven of 308 ltrs BEE 3 star capacity complete all as specified and as directed by Engineer-in-Charge. Make: Voltas/Samsung/LG
Disconnection and removing the unserviceable Split AC Outdoor & Indoor Unit/ window type of Capacity 1.5 to 2 Ton capacity from the existing position carefully for finding of the defects and to replace the unserviceable spare parts such as Compressor, Condensor Fan Motor, Condensor Coil, Suction & Discharge valves, mother plates including carry out leak detection test, Gas charging, servicing such as cleaning and removing the dust particles accumulated in the unit and filters carefully and washing the cooling unit and Indoor unit with water and refixing the same in its original position complete including connecting up of the Copper Tubes and cable connections, testing and commissioning complete all as specified and as directed by Engineer in charge. Make of existing ACs. Make:- LG/Blue Star/Hitachi/Voltas . (i) Cost of spares such as Compressor, Condensor Fan Motor, Condensor Coil, Suction & Discharge valves, mother plates, leak detection test, Gas charging shall be measured and paid separately under the respective Schedule 'A' Item. (ii) Makes & Specifications of the spare parts for replacement should be identical equivalent to the spares suitable for existing ACs.
Supply only Outdoor hermatically sealed Compressor Unit of Capacity 1.5 Ton Single Phase for Split Type ACs complete all as specified and directed by Engineer in charge. Make:LG/Hitachi/Voltas/Blue Star
Supply only indoor sealed Compressor Unit of Capacity 1.5 Ton Single Phase for window ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Outdoor hermatically sealed Compressor Unit of Capacity 2 Ton Single Phase for Split Type ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only indoor sealed Compressor Unit of Capacity 2.0 Ton Single Phase for window ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Condensor Fan Motor 230 Volt suitable for 1.5 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Fan Motor 230 Volt suitable for window type AC of 1.5 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Fan Motor 230 Volt suitable for window type AC of 2.0 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Blower Unit of Indoor unit Split type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only blower motor suitable for window type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit made out of Copper tubing suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of window Type Air Conditioning complete all as directed.
Supply only PCB/Mother Board Unit alongwith Remote Control Unit suitable for 1.5/2 Ton Indoor Unit of Split Type Air Conditioning complete all as directed.
Disconnection and Removing the unserviceable /broken Fan Blade from the Outdoor units of Split AC Unit 1.5 / 2 Ton Capacity and S&F New Fan Blade Unit complete suitable for existing AC Unit.
Disconnection and Removing the unserviceable running capacitors from the Outdoor units of Split Type AC Unit 1.5/2 Ton Capacity and S&F New Capacitors of capacity 36MFD, 230 Volts, ISI Marked.
Disconnection and Removing the unserviceable Starting Capacitors from the Outdoor units of Split Type AC Unit 1.5/2 Ton Capacity and S&F New Capacitors of capacity 100-120MFD, 230 Volts, ISI Marked.
Disconnection and removing the unserviceable Display Unit and S&F Digital Display for indicating Temperature, Temperature Sensor for 1.5/2 Ton Split AC Unit complete all as directed. Make :- LG/Hitachi/Voltas
Supply and Charge Refrigerant (R-22)/410a/407C Suitable for existing 1.5 Ton Capacity Split / Window type air conditioning unit complete all as directed.
Supply and Charge Refrigerant (R-22)/410a suitable for existing 2 Ton Capacity Split / Window type air conditioning unit complete all as directed.
Disconnection and Removing the damaged Flexible PVC Drain Pipe of dia 25mm and S&F New Standard Flexible PVC Drain Pipe of dia 25mm for capacity 1.5 ton, 2.0 ton Capacity.
Disconnection and removing the Old unserviceable Copper Pipe between Indoor & Outdoor Unit and S&F New Copper Pipe of 1/2" dia and connecting alongwith Insulation Sleeves to the existing position incl leak testing complete all as directed by Engineer in charge.
All as per Item No 111 here in above but of capacity 1/4" dia
S&F Suction Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
S&F Suction Valve made of Brass suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Material and labour for Internal wiring for split unit of any capacity with single core copper conductor FRLS cable as per existing size only complete all as specified and as directed by Engineer-in-Charge.
Disconnection and Removing the Cable connection and Copper pipe alongwith all connection items carefully from the existing indoor and out door units and Pump down the refrigerant from out door unit of tonnage 1.5/2 ton including stablizer from the existing position and shifting the AC unit at new place and refixing the out door and indoor units with necessary copper tubing including topping up of gas and connecting stablizer etc for its proper functioning all as direcred and specified by Engineer-in-charge.
Disconnection and Removing the defective/damaged Industrial Plug & Socket Board and supply & fix Industrial Plug & Socket controlled 15/16Amp Single Pole ISI Marked in and including sheet metal enclosure suitable for 1.5/2 Ton capacity
Carried out of Leak Proof Test for detection of leakage of gas from the cooling unit & Copper Tubing for Indoor/Outdoor Unit of Air conditioner, Refrigerator, Water Cooler with liquid nitrogen gas and arresting by gas welding method complete and charging of refrigerant into the Air conditioner/Refrigerator/Water Cooler complete. Note :- The leakage to be observed for 24 Hours and after confirmation only the refrigerant is to be provided to the unit.
Disconnection and removing the unserviceable / burnt out Copper Cable between Indoor & Outdoor Unit and S&F PVC Insulated, PVC Sheathed, Multistranded Copper Cable 3Core 6 Sqmm, ISI Marked, 1100 volts Grade and connecting to the unit along with necessary fixing materials complete. Make: Polycab/Finolex/Havells
Disconnection and Removing the damaged Outdoor unit Split type and Supply fixing incl testing repairs Outdoor unit suitable for Split type AC 1.5 ton capacity complete accessories ( fan, fan motor,Condensor Coil Unit, Compressor) all as specified and directed by Engr-in-Charge.
S&F for Replacement to unserviceable air filter in live of Provied with new air filter suitable for window type/Split type AC 1.5/2 ton capacity complete all as specified and directed by Engr-in-Charge.
Disconnection and removing the U/S indoor unit and S&F Indoor unit suitable for Split type AC 1.5/2 ton capacity complete accessrise all as specified and directed by Engr-in-Charge.
Supply and fixing and testing in repairs split type air condioner 3star rating unit with indoor and out door having hot & cold provn poerated unit single phase 220volt complete of capacity 1.5 ton Installation includes copper tubing as reguired up to 10 mtr and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge Make:Voltas/hitachi/LG
Supply and fixing in repair voltage stablizer for automatic operation single naturally air cooled indoor type and designed for input variation between 170votl to 250volt with out put voltage stabilised at 230volt with accuracy of plus minus 2.5% and of capacity 20Amp/5KVA. Make: V Guard/servokon/
Disconnection and removing the U/S and fixing and testing in repairs window type air condioner 3star rating having hot & cold provn poerated unit single phase 220volt complete of capacity 1.5 ton Installation includes as reguired and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in Charge Make:Voltas/hitachi/LG
Disconnection and removing the old u/s Outdoor Stand and S&F New Outdoor Stand made of Iron bracket to accomodate the air conditioner along with fixing materials complete
Taking down carefully dismantling voltage stabilizer of capacity 03 KVA to 5 KVA, single phase 240 volt AC of any make and any size opening up for inspection necessary repair and replacement of worn out/defective spare parts, rewinding of main transformer with supper enameted copper wire of existing gauge and weight reassembling, connecting up, testing etc complete all as directed by Engineer-in-Charge (Necessary spare parts required for replacement shall be measured and paid for separately as supply only) and fixing is included under this item. Make of winding wire : Devi Dayal/Atlas/BPL
S&F relay condenser and electronic circuit suitable for voltage stabilizer of capacity 3 KVA to 5 KVA of existing make and size complete all as specified and as directed by Engineer-in-charge.
Disconnection and removing the U/S Desert Cooler of capacity 120/80 Ltrs from the existing position and transporting to local workshop for finding out the defects and to replace the unserviceable spare parts such as Fan Motor, Water Pump, Khas-Khas Pads etc and refixing the desert cooler to its original position complete all as specified and as directed. Make :- Mamta Products/Swastik/SM Coolers
S&F in repair fan motor with outer frame & blade working on 230 Volts, 50 HZ, 1/6 HP Make: Khaitan/CG/Bajaj.
S&F in repair Submersible Tulu pump/water lifting on 230 Volts, 50 HZ Make: Khaitan/CG/Bajaj.
S&F in repair 3Pin plug top, 5Amp, on 230 Volts AC.
Supply only Khas - Khas / wood wool pads of same size and good thickness set of 3 for desert cooler to the satisfaction of Engineer-in-Charge.
Taking out the old damaged front grill unit and replace the same with new front grill as per sample. Suitable for desert cooler
Taking out faulty distributer system consisting of PVC Elbow and PVC pipe and Supply and fix new water distributer 3 way consisting 3 Nos of PVC elbow and 1/2 " heavy duty PVC Pipe of length upto 2 mtrs suitable for existing desert coolers.
S&F in replacement brackets for fan motors of desert cooler made out of flat iron of size 25mmX3mm, 300 mm long, bent to shape and including drilling of holes (set of four) etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of shaft bush set of fan motor of desert cooler complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair fan blades (set of one blades) for 350 to 450mm desert cooler complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair mild steel Body desert cooler (elect drivn) single phase having air flow/delivery 3000cum/hrs duly painted with synthetic enamel paint on external surface & black japan paint on internal surface with gun spary machine. The desert cooler body shall be fabricated with the sections as under. (a) Top & bottom of the body shall be galteel.vanised sheet. (b) Side panel of the body (set of three) made out 1mm thick MS galvanised sheet with wire GI wire, dia 25mm mesh for holding pads. (c) front grill of suitable size and approved quality mild steel. (d) fixing of fan motor with blades, water lifting pump and electric wiring/fitting. (e) Desert cooler shall be fitted with kits consisting of fan motor, submersible tullu pump & three step regulator of Make: bajaj/Khaitan/CG.
Disconnecting and removing the U/S Body desert cooler and S&f in repair mild steel Body desert cooler (elect drivn) single phase having air flow/delivery 120/80Ltr duly painted with synthetic enamel paint on external surface & black japan paint on internal surface with gun spary machine. The desert cooler body shall be fabricated with the sections as under. (a) Top & bottom of the body shall be galteel.vanised sheet. (b) Side panel of the body (set of three) made out 1mm thick MS galvanised sheet with wire GI wire, dia 25mm mesh for holding pads. (c) front grill of suitable size and approved quality mild steel complete all as specified and as directed by Engineer-in-charge.
Taking out existing burnt / unserviceable compressor unit from the deep freezer, replacing the same with factory build hermatically sealed compressor unit alongwith its connected items, including carried out leak testing by dry nitrogen gas, charging of refrigerant after ensuring leak proof conditioned, Testing and commissioning of deep freezer of capacity 210 TO 315 ltrs. Make :- Blue Star/LG/Samsung
Disconnection and removing the unserviceable burnt Fan motor unit from the deep freezer and S&F New Fan Motor unit , Single phase, 230 volts 50 Hz of same size and capacity suitable for 165/210 / 310 ltrs deep freezer as per sample
Disconnection and removing the unserviceable starting relay unit, and S&F New Relay unit of same size and capacity suitable for 165 to 315 ltrs refrigerator
Disconnection and removing the unserviceable Timer switch, and S&F Timer switch of same size and capacity suitable for 165 to 315 ltrs refrigerator
Disconnection and removing the unserviceable broken freezer door plastic, and S&F New Door unit of same size and capacity suitable for 165 to 315 ltrs refrigerator
Disconnection and removing the unserviceable fused electric bulb, and S&F Bulb Unit of same size and capacity suitable for 165 to 315 ltrs refrigerator
Disconnection and removing the unserviceable Over Load Protector Unit, and S&F Over Load Protector Unit of same size and capacity suitable for 165 to 315 ltrs refrigerator
Cleaning the system with CTC and charging the refrigerant gas R-22/134 including replacing strainer and rectification of leakage of the system from deep frezzer of 320ltr capacity complete all as specified and as directed by Engineer-in-charge.
Disconnecting and removing the unserviceable Solar water heater of capacity 100 to 500 LPD from its original position along with connected items and to finding out the defects and refixing the same after repairs, making the same in serviceable condition in its original position connecting up water connections, testing and commissioning complete all as specified and directed by Engg-in-Charge. Note : (i) Spare parts such as Solar Water tank, water heater will be measured and paid separatley. (ii) Misc items required for satisfactory completion of Job deemed to be included in the unit quoted rate.
S&F Solar water tank made out of stainless steel alongwith puff insulation of capacity 500 ltrs with electrical heating backup of 2 KW including taking down old U/S solar water tank. Make of existing geyser :-Kamal / BHEL / Tata BP / inter solar
Supply only Solar water heater collector (heat exchanger) for 500 ltrs solar water heater of same size and capacity complete for 500 ltrs solar water heater of same size and capacity complete connecting up of connections complete all as specified and as directed. Make :-Kamal/BHEL/Tata BP/ inter solar
Disconnecting and removing the unserviceable PVC water tank of capacity 500 Ltr from its original position along with connected items and to finding out the defects and refixing the same after repairs, making the same in serviceable condition in its original position connecting up water connections, complete all as specified and directed by Engg-in-Charge.
Taking down carefully u/s point wiring and M&L for Point wiring complete with 1.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc, including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc all as specified and as directed for One 3 pin socket outlet 5 Amps on independent board .(for Desert Coolers)
All as per Item No 154 here in above but for One ceiling fan/ exhaust fan point controlled by one, one way 5 Amps switch
Taking down carefully u/s point wiring and M&L for Point wiring complete with 4 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 4 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc all as specified and as directed for One 3 pin socket outlet 5 Amps on independent board. (for geyser & AC Point)
Taking down carefully u/s point wiring and M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and modular type metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc all as specified and as directed for one switch socket outlet 15 Amps on independent board complete all as specified and as directed by Engineer-in-charge.(Water coolers and Refrigerators)
Supply and Fixing switch socket combination flush type universal 2 in 1, 3 pin 5 Amps
Supply and Fixing switch socket combination flush type universal 2 in 1, 3 pin 15 Amps
Supply and fix MCB SPN 230 volts 32 Amps with 10KA breaking capacity.Make-Standard/Havells/Indo asian.
Supply and fix MCB SP 230 volts 6-32 Amps with 10KA breaking capacity. Make-Standard/Havells/Indo asian.
Supply and fix MCB DB SPN 4 way double door with 200 amps rated bus bar complete all as spfd and directed.
Disconnection and removing the u/s 3X1.5 Sqmm PVC insulated unsheathed cable from the existing conduit and M&L for 3X1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor drawn in the existing metal/ PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete. Note : Three runs of cable measured as one unit.
All as per Item No 163 here in above but of 3X2.5 Sqmm.
All as per Item No 163 here in above but of 3X4 Sqmm.
All as per Item No 163 here in above but of 2X6 Sqmm.
Disconnection and removing the u/s regulator and Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling / exhaust fan flush type.
Disconnection and removing the u/s ceiling rose and S&F Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body.
Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete.
M/s badrinath Traders
M/S BALWINDER SINGH
GURU NANAK CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .