Loading…
Loading…
Tender Value
₹56.5 Cr
EMD Value
₹56.5 L
Closing Date
15 Oct 2026, 11:00 am
NBCC Bhawan
NBCC Bhawan
Comprehensive ARM and Operation of Civil, E and M Services (Internal and External), Housekeeping, Security Services, STP, Horticulture, Landscaping works, etc. at Office Block 1 to 4, East Kidwai Nagar, New Delhi
NBCC/SBGRFM/EKN/2026/16~EWf89e5267be75bbc10da49131
NBCC/SBGRFM/EKN/2026/16
Open Tender-Domestic
Miscellaneous Services
NBCC Bhawan
₹1.2 L
₹56.5 L
24 Sept 2026
24 Sept 2026
15 Oct 2026
24 Sept 2026
15 Oct 2026
ABSTRACT OF COST
Sr. Non-Schedule Amount
Description including Cost
A Civil, Electrical & Mechanical
CIVIL WORKS i/c SANITARY , WATER SUPPLY & SEWERAGE SYSTEM,
2.0 INTERNAL ELECTRICAL INSTALLATIONS 2,26,55,964.63
ARM OF WET RISER & SPRINKLER SYSTEM, DRINKING WATER & SUMP
3.0 PUMP SYSTEM, FIRE ALARM, DETECTION SYSTEM RAIN WATER 1,58,60,032.59
HARVESTING AND STP.
ANNUAL RUNNING & OPERATION OF EXTERNAL ELECTRIFICATION,
4.0 ELECTRIC SUB-STATION EQUIPMENT, GAS GENSET, ROOFTOP ON GRID 2,86,77,859.96
SOLAR POWER SYSTEM.
5.0 LIFTS OPERATION 1,43,12,876.10
6.0 ANNUAL REPAIR OPERATION & MAINTENANCE OF HVAC & BMS 2,21,10,779.86
7.0 HORTICULTURE WORK 70,27,442.19
8.0 Cleaning Water tank 8,77,206.42
10.0 DISPOSAL OF GARBAGE ETC. 5,38,794.40
11.0 Day-Today CIVIL WORKS : INTERNAL & EXTERNAL FINISHING 76,47,154.89 51,76,890.20
12.0 Civil works for Maintenance 1,79,61,696.19 66,34,954.55
13.0 Electrical Works 45,65,843.37 36,58,405.57
15.0 AMC of GG SETS 1,96,06,684.67
16.0 CAMC of Boom Barriers, Flap Barriers and ANPR Cameras 1,14,26,276.75
Comprehensive Annual Maintenance Contract (CAMC) for Chiller
C Watch & Ward
D Special Repair
Total Cost (DSR Amount + Non-Schedule items Amount) in Rs. 56,45,06,082.67
Say in Cr. 56.45
Digitally signed by RAJ PAL
NBCC (INDIA) LIMITED
COMPREHENSIVE ARM AND OPERATION OF CIVIL, E & M SERVICES (INTERNAL & EXTERNAL), HOUSEKEEPING, SECURITY SERVICES, HORTICULTURE/LANDSCAPING & STP WORKS, ETC. AT OFFICE BLOCK 1 TO 4 AT EAST KIDWAI NAGAR, NEW DELHI .
BILL OF QUANTITIES
DSR CIVIL-2023 Description of item of work RATE IN RS. AMOUNT IN RS
S.No. Unit QTY
DSR ELECT.-2025 DSR NS DSR NS
1.00 SH - I: CIVIL WORKS i/c SANITARY , WATER SUPPLY & SEWERAGE SYSTEM, HOUSEKEEPING
Annual repair & maintenance and upkeep of all internal and external assets i/c watch and ward, security of service centre,
under ground & over head tanks, complete with all materials labour, T&P , machines , trucks etc. as required on all days
1 NS including Sunday and holidays comprising of following operations as per the details of common service area with external
services as per enclosed GCC, Special & other conditions, specifications etc. complete and as per direction of the engineer
Cleaning and maintenance of roads, pavements, footpaths, open areas, drains, floor of common areas such as lift, lobby,
staircases, basement parking/ spaces etc. inside the campus and disposing of resulting rubbish/ garbage etc,
includingtransportation of garbage to the nearest to the municipal dumping dhalao/ yard/ treatment plant complete to keep
a) the entire office campus neat and clean including mechanised wet mopping periodically of Lift, lobby, staircase at least
alternate days with phenyl and terrace cleaning once in a week complete to the entire satisfaction and as per directions of
Engineer- in- charge.
Sweeping and wet mopping of service centre, office, common area in all commercial blocks, toilets, staircase, lifts, lobby,
pump house, STP, adjoining open area, roads, pavements, security room, basement parking etc twise a day cleaning of
glass panes, facia/facade of building, (periodically as and when required) and Atrium, washing of parking area and
b) surrounding once in a week brooming wet mopping daily of fire escape staircase, main staircase, entrance lobbies and
terrace cleaning, terrace solar panels to be done weekly and attrium alternate daysincluding mechanised wet mopping
periodically of Lift, lobby, staircase at least alternate days with phenyl complete to the entire satisfaction and as per
direction of Engineer- in- charge.
Periodical cleaning & Maintenance of sewerage, drainage network & Rain water harvesting system manually or using
Pressure jetting machines twice in a year or more, if required, i/c desiliting of gully traps, manholes, gratings, chocked
c) sewer line, water closet including all the vertical stacks of Sanitary and rain water pipes of all sizes i/c khurrah twice in a
year or more ,if required, to the entire satisfaction of Engineer - in - Charge.
Maintenance and cleaning of chajjas, cornice basement, roofs, expansion joints etc, and removing of cobwebs, beehives,
vegetation including disposal of slit, vegetation, malba. waste garbage etc. to the authorized dumping ground outside the
campus at the location approved by MCD/NDMC complete to the entire satisfaction and as per the direction of Engineer - in -
Maintenance and operation of water supply grid and valves including unfiltered water supply line, STP effluent water line in
e) the entire campus to keep the water supply system efficient and operational at all times to the entire satisfaction and as
per direction of the Engineer - in - Charge.
Maintenance and repairing and fixing of damaged doors, windows, ventilators of steel, aluminium, wood , PVC including
replacement of broken glass panes etc. at all floors & heights i/c repair/ replacement of necessary fittings & fixtures of
f) approved make and quality, wherever required to keep them in proper functional conditions to the entire satisfaction and as
per the direction of the Engineer - in - charge .
Maintenance and repair of plumbing system of the entire campus including stopping leakages or over flow of water from
PVC/RCC over head tanks, cisterns and replacement of damaged fittings i/c CP Brass fitting, ball cocks and G.I., PVC
fittings sensor device etc to keep the entire water supply system efficient and functional to the entire satisfaction and
as per direction of Engineer - in - charge .
Maintenance and repair of internal & external plaster, flooring, pavements/Footpaths, masonry & RCC works, pointing on
roof tiles , patch plaster on area upto 2.5 sqm, CC gola i/c fixing of W.C. seat, gully trap, W.C trap, floor traps and
h) sealing of leakages from gully trap, W.C trap, floor trap, drainage and vertical stacks, expansion joints etc. and restoration
of existing finishing in the affected areas to match with adjacent finishes and to the entire satisfaction and as per direction
of Engineer -in - charge.
Welding by electric plant including transportation of electric welding plant at site to weld broken grills, hinges, doors,
i) windows, gates, railing and any other steel work in building, etc. complete as per direction and as per direction of Engineer -
Investigating causes of seepage / dampness/ leakage from roof, wall, floors, pipes expansion joints of all kinds etc.,
dismantling existing affected portion, arranging required materials, labours, T&P, lift/ ladder including taking all necessary
measures, rectification complete in all respect in time bound manner to the entire satisfaction and as per direction of
Engineer - in - charge
Replacement of broken, damaged, edge depressed & reverse flow flooring
/pavements with different kind of stones/ tiles including base mortar/ adhesive to match with surrounding colour, shade
and pattern of stones/ tiles etc to the entire satisfaction and as per direction of the Engineer - In- Charge.
l) Maintenance and replacement of the damaged convex reflective mirror
Periodical cleaning & Maintenance including repalcement of the damaged external façade stone of any size/area and at any
m) height without any extra cost
Fabrication works in Main Gates, Stair cases, i.e realignments, additional tower bolts, sliding bolt, hold fasts etc including
n) making holes & welding wherever required and finished to the entire satisfaction and as per direction of Engineer in-
Digitally signed by RAJ PAL
Operation & maintenance of command & control centre at each tower connecting CCTV, fire, lifts, parking & other services
etc. and reporting of any service including fire, water, lift operation, theft or any other incident to the supervisior/ manager
of the contractor and Engineer In-charge and nearest fire station/ police station as the case be.
p) Cutting RCC & providing hooks for additional ceiling fans including repair to original finished surface .
Closing holes in walls, ceilings, floors or any wherelse including repairing with cement mortar to prevent entry of rats &
others animals.
Providing services of one office attendant/ computer operator to assist the NBCC staff at maintenance service centre at
commercial blocks of Kidwai nagar, New Delhi.
s) Downloading the complaints received on IVRS/ Emails on daily basis.
Operation, Recording & maintenance of the complaints register received at service centres in person or through telephone
t) and assigning the complaint to the workers of respective trade.
Uploading all the complaints received at the service centre in the IVRS/ Emails/ E- sewa system on daily basis.
uploading the status of attending of the complaints on daily basis on IVRS/ Emails/ E- sewa system so that the backlog is
not more then one day.
Preparing the abstract of attended / unattended complaints on daily, weekly and monthly basis and submitting the same
w) with reasons of unattended complaints and action plan for redressal of pending complaint to the Engineer- in - charge of
the service centre or his authorized representative.
x) Any other miscellaneous works connection with above as per direction of Engineer- in- charge.
Cleaning of RCC/PVC drinking water storage Under ground & over head tanks twice in a year or more, if required, by
adopting 6 stage process i.e dewatering, sludge removal, high pressure cleaning, vacuum cleaning, antibacterial spray and
y) ultra violet-radiation i/c mentioning the date of cleaning on each tank. complete in all respect to the entire satisfaction of the
Engineer- in-charge. (this item will be paid separetly as per actual execution at site)
All inclusive Annual Repair & maintenance, repair/replacement of motors/pumps/all water incoming/ outgoing lines and
providing services for running operation of water supply of centrifugal/ submersible pump sets i/c associated motor, control
panel, auto system, all the installation in two shifts on all days including Sundays & Holidays, as per terms and conditions
and as per dire ction of Engineer -in-charge.
The contractor shall be mixing bleaching and chlorine of standard quality as per requirement in the drinking water supply.
The rate shall be inclusive of all the material and operation, labour etc. involved.
Any other civil works such as cleaning of glass panes, Signage’s, murals, paintings & furniture etc daily and the items in
ab) connection with the smooth operation & maintenance work not mentioned above, but required to be carried out with in
the cost and/ or also as per direction of the Engineer -in - charge .
NS maintenance for above work:
SUB TOTAL OF INTERNAL CIVIL WORK INCLUDING HOUSEKEEPING Per Month 36.00 41,75,040.30 15,03,01,450.84
2 SH-II : INTERNAL ELECTRICAL INSTALLATIONS
All inclusive Annual Repair & maintenance, upkeep of all electrical internal & external installations, Lights, Fans, Geysers
a etc. as per details below at Commercial block, kidwai nagar, New Delhi in 24x7 for all days in a month i/c sundays and
holidays complete with materials, and as per direction of Engineer -in-Charge.
• Light points/ Fan pts/ Ex-fan pts./ Call bell pts.
• 5 amp plug points, 15 amp power plug points
• 20/30 amp Ind. Power plug points
• Telephone outlet, TV Outlet
• Telephone wire, TV Wire , OFC, Splitters
• LED light fittings
• All type of light fittings
• Ceiling fans, Ex-fans
• Call bells,DBS,Rising Mains tap of box
• SP, SPN, TP & TPN MCB DB’s with MCB’s
• Bus Bars, Bus duct and Tap off box of different ratings
• Cable trays of different size
b • 63/100 amps TP & N Switch units
• 125 Amp. TP MCCB’s
• Street Lights, and compound lights with LED fittings, control gears etc.
• All type of feeder pillars with switch gears etc.
• All HT, LT, UG cables for streetlights.
• And others as desired by Engineer-in-charge.
• All panels i/c UPS Panels and common area lights Street light, pump house, basement parking, STP etc.
• Lightning Arrestor System
• Earthing system
c Pump House, UG Tank
d Any other pumpset/ other installation
Any other works in connection with the smooth operation & maintenance work not mentioned above, but required to be
carried out with in the cost and/ or also as per direction of the Engineer -in - charge .
Digitally signed by RAJ PAL
maintenance for above work
SUB TOTAL OF INTERNAL ELECTRICAL WORK Per Month 36.00 6,29,332.35 2,26,55,964.63
3 SH-III : ARM OF WET RISER & SPRINKLER SYSTEM, DRINKING WATER & SUMP PUMP SYSTEM, FIRE ALARM, DETECTION SYSTEM RAIN WATER HARVESTING AND STP.
All inclusive AR & maintenance of fire-fighting system i.e. including providing services for operation of manual fire alarm
3.1 ,detection system, down comer system, Pumps intercom & Lift intercom, 24x7 on all days of the year including Holidays as
per terms and conditions attached i/c periodical fire testing, mock drill & obtaining fire clearance certificate as & when
NS All water lines, motor, pumps, electrical wiring, intake, any other Pump/machinery installed etc.
Any other works in connection with the smooth operation & maintenance work not mentioned above, but required to be
3.3 carried out with in the cost and/ or also as per direction of the Engineer -in - charge .
maintenance for above work
SUB TOTAL OF ARM OF WET RISER & SPRINKLER SYSTEM, DRINKING WATER & SUMP PUMP SYSTEM, FIRE
ALARM, DETECTION SYSTEM, ETC.
SH-IV : ANNUAL RUNNING & OPERATION OF EXTERNAL ELECTRIFICATION, ELECTRIC SUB-STATION EQUIPMENT, GAS GENSET,
All inclusive AR & maintenance i/c providing services for operation of electric sub-station equipments and Gas Genset i/c
their cooling towers, Solar power generation system, on all days of the year including Sunday & Holidays as per terms and
Running, Operation & AR & maintenance of - 12 nos. ( 8 nos. 1450 KVA and 4 nos. 720 KVA) stand by Gas Generator sets
on all the days including Sundays & Holidays complete with all materials i/c Oil etc as per terms and conditions attached.
Gas Generator sets
(i) 1450 KVA Gas Genset (T1-2, T2-4, T3-1, T4-1)
(ii) 720 KVA Gas Genset (T1-2, T3-1, T4-1) including transformer & panel of each tower with gas genset
Ring Main Unit ( RMU ), SF6 Circuit Breaker ( 630 A each ) HT Panel Board 11KV VCB 630A each ( I/C - 1 & O/G - 2 )24V
DC Supply System ( BTU ) 220V AC UPS with SMF Batteries 11KV , 3C x 185
4 sq.mm. XLPE Aluminium cable 11KV , 3C x 240 sq.mm. XLPE Aluminium cable Main LT Panel
Incommer - 1 Gas Genset - 1 ( 1250A ACB ) Incommer - 2 Gas Genset - 2 (2500A ACB ) Incommer - 3 Gas Genset - 3
( 2500A ACB ) Incommer - 4 Transformer - 2 (3200A ACB ) Incommer - 5 Transformer - 2 ( 3200A ACB ) Incommer - 6
Gas Genset - 4 (1250A ACB ) Bus Coupler - 1 - 2500A ACB Bus Coupler - 2 - 3200A ACB
Bus Coupler - 3 - 2500A ACB Outgoing - 43 Nos (Please refer SLD)
Weekly preventive maintenance shall be essentially carried out by deploying full team on Tuesday to check each & every
civil , electrical,fire fighting, fire alarm , pumps items etc and maintained the record.
Any other item(s)/ work(s) in connection with above shall be carried out as per direction of the Engineer -in - charge .
maintenance for above work
Sub Total of ANNUAL RUNNING & OPERATION OF EXTERNAL ELECTRIFICATION, ELECTRIC SUB-STATION
EQUIPMENT, GAS GENSET, ROOFTOP ON GRID SOLAR POWER SYSTEM.
5 SH-V : LIFTS OPERATION
Providing services for running operations i/c cleaning and safety, security, watch& ward of following lifts on all days of the
a NS year including Sunday & Holidays as per terms and conditions.
Lift of M/s. Schindler Elevators (16 Passenger with Gearless MRL Elevator System - 9Nos for each block)
Lift of M/s. Schindler Elevators (1500 kgs Service Lift with Gearless MRL Elevator System - 2Nos for each block)
d 4 nos. Lift of M/s Schindler for Exhibition Centre
Sub-Total of Lifts Operation Per Month 36.00 3,97,579.89 1,43,12,876.10
6 SH-VI : ANNUAL REPAIR OPERATION & MAINTENANCE OF HVAC & BMS
All inclusive AR & maintenance i/c providing services for operation of four nos HVAC Plant of T3&T4 - 200 TR, T1- 325TR,
T2- 500TR as per terms and conditions attached i/c , their cooling towers , Basement Ventillation system, AHUs, etc. with
all materials such as refrigerant gas, moble oil, grease etc complete as per direction of Engineer-in -charge. (Maintenance
NS of Chiller shall be carried out through OEM)
Annual Maintenance Contract (AMC) of 14 Nos. of Chillers through the Original Equipment Manufacturer (OEM), i.e. DAIKIN,
or its authorized agency. The agency shall engage the OEM for carrying out the AMC, and the original copy of the
b contract/agreement with the OEM shall be submitted to NBCC immediately after award of the work. Subsequent AMC
payments shall be released only upon submission of a certificate from the OEM confirming receipt of the previous payment
by the agency, along with the respective RA Bill.
c NS Basement ventilation, supply/ exhaust & fresh air system (Ground & above)
maintenance for above work
Sub-Total of ANNUAL REPAIR OPERATION & MAINTENANCE OF HVAC & BMS Per Month 36.00 6,14,188.33 2,21,10,779.86
7 SH-VIII : HORTICULTURE WORK
Digitally signed by RAJ PAL
Complete maintenance of the entire garden features of the garden area i/c lawn, tress, shrubs, hedge, potted plants,
flower beds, creepers etc. and other garden features including watering, hoeing, making of plants basin, manuring,
trimming and cleaning of hedges/ plants beds, spraying of insecticides, fungicides, weeding, mowing and top dressing of
a NS lawn with good earth and manure and hedge clipping and removal of the garden waste as per direction and satisfaction of
the officer-in- charge (including the cost of manure and good earth) to maintain the plants, hedge and lawns in good
and healthy conditions at all the time during the maintenance period as mentioned in general terms & conditions
Entire Commercial Complex and inside the compound wall and outer periphery of front side compound wall & at entrance
maintenance for above work
Sub-Total for Horticulture Work Per Month 36.00 1,95,206.73 70,27,442.19
8 SH-IX : Cleaning Water tank
Cleaning of under ground sump, over head RCC Tank (independent staging) including disposal of silt and rubbish, all as per
a 14.78 direction of Engineer- in- charge. The cleaning shall consist following operations:-
b (i) Tank shall be empited of water by pumping & bottom shall be cleaned of silt and other deposits.
Entire surface area of the sump shall then scrubbed throughly with wire brush etc. and pressure washed with water.
d (iii) Chlorination of RCC internal surface by liquid chlorine.
The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.
f (v) Finally the surface shall be treated ultraviolet radiation etc. as per direction of Enginerr- in - charge.
maintenance for above work
Sub-Total for Cleaning of Water Tank Sqm 10,520.00 83.38 8,77,206.42
NS Subject: Comprehensive Operation and maintenance of 1 no. sewage treatment plant (1500KLD) based on SBR technology at Office Complex, Kidwai Nagar (East), New Delhi-110023.
comprehensive operation and maintenance of the 2 no. STP plant (1x1500KLD + 1x650KLD) 24*7hours
Maintenace, Repairing including major & minor all type of maintenance and all instrument installed should be kept in
a operation and in good health at the satisfaction of Engineer Incharge per month 36.00 2,78,115.56 1,00,12,160.11
Supply of various chemical, consumables etc. for plant operation for 1 no. sewage treatment plant (1500KLD)
b based on SBR technology at Office Complex, Kidwai Nagar (East), New Delhi-110023. are followings.
iv Bio Culture Ltr 81.00 587.21 47,563.99
v Sodium Hypo Chloride Ltr. 32,400.00 27.33 8,85,555.07
vi Salt for Softener KG 14,400.00 10.76 1,54,972.14
viii Multi grade filter (Media), once in 2 years Kgs. 19,500.00 10.25 1,99,864.86
ix Pebble & Gravel for Activated carbon filter, once in 2 years Kgs. 7,800.00 10.25 79,945.94
x Activated carbon for activated carbon filter, once in 2 years Kgs. 3,000.00 89.68 2,69,048.85
xi Softener Resin, once in 2 years Kgs. 4,000.00 181.93 7,27,713.08
Lab Chemicals & consumables.
Daily Lab testing of Inlet and Outlet water at Sewage Treatment Plant (BOD, COD, TSS, ph, Hardness, TDS,
Total Coliform, Oil & Grease, etc.)
1. Test will be done on daily basis of inlet/outlet/treated water/soft water.
2. Frequency of testing of treated water on half yearly basis from NABL approved laboratory is also included in this price.
3. Cost of all chemicals to be used in testing and cost of calibration including maintenance & replacement of damage part of
xii Non-DSR lab equipment shall be included with in the quoted rates. month 36.00 20,000.00 7,20,000.00
4. Test record will be maintained on daily basis.
5. Testing of Domestic water from NDMC on half yearly basis in contractors scope within the quoted rates.
NOTE: The contractor will maintain a regular IMIR (Inward Material Inspection register) for the cosumables.
Following items will be replaced in case these are damaged and non repairable as per direction of Engineer in
Chage complete in all respect.
xiii Electrical -spare parts
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of
Xiii-1 2.10 following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Xiii-5 2.10.5 Triple pole and neutral NOS. 10.00 1,240.28 12,402.80 -
Xiii-8 NS Over Load Relay 5 amp - 8 amp Nos. 1.00 3,372.52 3,372.52
Xiii-9 NS Over Load Relay 10 amp - 16 amp Nos. 1.00 4,215.65 4,215.65
Xiii-10 NS Over Load Relay 12.5 amp - 20 amp Nos. 1.00 3,091.48 3,091.48
Xiii-11 NS Over Load Relay 6.3 amp - 10 amp Digitally Nos. 1.00
signed by RAJ PAL 2,810.43 2,810.43
Xiii-12 NS Over Load Relay 1 amp - 1.6 amp Nos. 1.00 2,810.43 2,810.43
Xiii-13 NS Over Load Relay 20 amp - 32 amp Nos. 1.00 7,728.69 7,728.69
Xiii-14 NS Over Load Relay 0.8 amp - 1.25 amp Nos. 1.00 3,513.04 3,513.04
Xiii-15 NS Over Load Relay 0.9 amp - 1.5 amp Nos. 1.00 3,232.00 3,232.00
Xiii-16 NS Contactor, 12 amp Nos. 1.00 2,810.43 2,810.43
Xiii-17 NS Contactor, 09 amp Nos. 1.00 2,248.35 2,248.35
Xiii-18 NS Contactor, 16 amp Nos. 1.00 3,091.48 3,091.48
Xiii-19 NS Contactor, 32 amp Nos. 1.00 9,274.43 9,274.43
Xiii-25 NS Star Delta Timmer Nos. 1.00 3,232.00 3,232.00
Xiii-26 NS PLC with programing Nos. 1.00 2,52,938.97 2,52,938.97
Xiii-27 NS HMI with programing NOS. 1.00 83,148.91 83,148.91
Xiii-28 NS Indicating lights, 220 Watt Nos. 20.00 562.09 11,241.73
Xiii-29 NS Selector Switches Nos. 25.00 702.61 17,565.21
Xiii-30 NS Mechanical parts & Spares Blower parts & Spares - -
Xiii-33 NS Bearing , for 770 m3 blower Nos. 2.00 47,777.36 95,554.72
Xiii-34 NS Bearing , for 1200 m3 blower Nos. 2.00 49,013.95 98,027.90
Xiii-35 NS Gear set , for 770 m3 blower Nos. 2.00 84,312.99 1,68,625.98
Xiii-36 NS Gear set , for 1200 m3 blower Nos. 2.00 89,933.86 1,79,867.71
Xiii-37 NS Rotor for , 770 m3 blower Nos. 2.00 95,554.72 1,91,109.45
Xiii-38 NS Rotor for , 1200 m3 blower Nos. 2.00 1,06,796.46 2,13,592.91
Xiii-39 NS Packing for 770 m3 blower Nos. 4.00 2,698.02 10,792.06
Xiii-40 NS Packing for 1200 m3 blower Nos. 4.00 2,698.02 10,792.06
Xiii-41 NS Belt ( flat belt ) for 770 m3 blower Nos. 4.00 2,107.82 8,431.30
Xiii-42 NS Belt ( flat belt ) for 1200 m3 blower Nos. 4.00 2,248.35 8,993.39
Xiii-43 NS Oil seal for 770 m3 blower Nos. 4.00 7,588.17 30,352.68
Xiii-44 NS Oil seal for 1200 m3 blower Nos. 4.00 7,588.17 30,352.68
Xiii-45 NS Safety valve for 770 m3 blower Nos. 2.00 11,241.73 22,483.46
Xiii-46 NS Safety valve for 1200 m3 blower Nos. 2.00 11,241.73 22,483.46
Xiii-47 NS NRV for 770 m3 blower Nos. 2.00 11,241.73 22,483.46
Xiii-48 NS NRV for 1200 m3 blower Nos. 2.00 14,052.17 28,104.33
Xiii-49 NS Re-Winding of the Motors Capacity in Horse Power - -
Xiii-50 NS Re-Winding of the Motors Capacity in Horse Power: 2 Nos. 1.00 3,202.96 3,202.96
Xiii-51 NS Re-Winding of the Motors Capacity in Horse Power: 5 Nos. 1.00 6,405.93 6,405.93
Xiii-52 NS Re-Winding of the Motors Capacity in Horse Power: 7.5 Nos. 1.00 8,327.70 8,327.70
Xiii-53 NS Re-Winding of the Motors Capacity in Horse Power: 10 Nos. 1.00 8,968.30 8,968.30
Xiii-54 NS Re-Winding of the Motors Capacity in Horse Power: 12.5 Nos. 1.00 10,890.07 10,890.07
Xiii-55 NS Re-Winding of the Motors Capacity in Horse Power: 15 Nos. 1.00 11,530.67 11,530.67
Xiii-56 NS Re-Winding of the Motors Capacity in Horse Power: 20 Nos. 1.00 15,374.22 15,374.22
Xiii-57 NS Bush for Motors Capacity in Horse Power - -
Xiii-60 NS Bush for Motors Capacity in Horse Power: 7.5 Nos. 1.00 3,202.96 3,202.96
Xiii-61 NS Bush for Motors Capacity in Horse Power: 10 Nos. 1.00 3,843.56 3,843.56
Xiii-62 NS Bush for Motors Capacity in Horse Power: 12.5 Nos. 1.00 3,843.56 3,843.56
Xiii-63 NS Bush for Motors Capacity in Horse Power: 15 Nos. 1.00 4,484.15 4,484.15
Xiii-64 NS Bush for Motors Capacity in Horse Power: 20 Nos. 1.00 4,484.15 4,484.15
Xiii-65 NS Shaft for Motors Capacity in Horse Power - -
Xiii-66 NS Shaft for Motors Capacity in Horse Power: 2 Nos. 1.00 3,202.96 3,202.96
Xiii-67 NS Shaft for Motors Capacity in Horse Power: 5 Nos. 1.00 5,765.33 5,765.33
Xiii-68 NS Shaft for Motors Capacity in Horse Power: 7.5 Nos. 1.00 7,046.52 7,046.52
Xiii-69 NS Shaft for Motors Capacity in Horse Power: 10 Nos. 1.00 9,608.89 9,608.89
Xiii-70 NS Shaft for Motors Capacity in Horse Power: 12.5 Nos. 1.00 9,608.89 9,608.89
Xiii-71 NS Shaft for Motors Capacity in Horse Power: 15 Nos. 1.00 10,249.48 10,249.48
Xiii-72 NS Shaft for Motors Capacity in Horse Power: 20 Nos. 1.00 12,171.26 12,171.26
Xiii-73 NS Impeller for Pumps Capacity in Horse Power - -
Xiii-74 NS Impeller for Pumps Capacity in Horse Power: 2 Nos. 1.00 4,484.15 4,484.15
Xiii-75 NS Impeller for Pumps Capacity in Horse Power: 5 Nos. 1.00 8,327.70 8,327.70
Xiii-76 NS Impeller for Pumps Capacity in Horse Power: 7.5 Nos. 1.00 10,249.48 10,249.48
Xiii-77 NS Impeller for Pumps Capacity in Horse Power: 10 Nos. 1.00 11,530.67 11,530.67
Xiii-78 NS Impeller for Pumps Capacity in Horse Power: 12.5 Nos. 1.00 11,530.67 11,530.67
Xiii-79 NS Impeller for Pumps Capacity in Horse Power: 15 Nos. 1.00 14,093.04 14,093.04
Xiii-80 NS Fan ( Backward curve blade ) Capacity in Horse Power - -
Xiii-81 NS Fan ( Backward curve blade ) Capacity in Horse Power: 2 Nos. 1.00 640.59 640.59
Xiii-82 NS Fan ( Backward curve blade ) Capacity in Horse Power: 5 Nos. 1.00 896.83 896.83
Xiii-83 NS Fan ( Backward curve blade ) Capacity in Horse Power: 7.5 Nos. 1.00 960.89 960.89
Xiii-84 NS Fan ( Backward curve blade ) Capacity in Horse Power: 10 Nos. 1.00 1,024.95 1,024.95
Xiii-85 NS Fan ( Backward curve blade ) Capacity in Horse Power: 12.5 Nos. 1.00 1,281.19 1,281.19
Xiii-86 NS Fan ( Backward curve blade ) Capacity in Horse Power: 15 Nos. 1.00 1,537.42 1,537.42
Xiii-87 NS Fan ( Backward curve blade ) Capacity in Horse Power: 20 Nos. 1.00 1,537.42 1,537.42
Xiii-96 NS Connection Plate Capacity in Horse Power - -
Xiii-97 NS Connection Plate Capacity in Horse Power: 2 Nos. 1.00 320.30 320.30
Xiii-98 NS Connection Plate Capacity in Horse Power: 5 Nos. 1.00 320.30 320.30
Xiii-99 NS Connection Plate Capacity in Horse Power : 7.5 Nos. 1.00 512.47 512.47
Xiii-100 NS Connection Plate Capacity in Horse Power : 10 Nos. 1.00 960.89 960.89
Digitally signed by RAJ PAL
Xiii-101 NS Connection Plate Capacity in Horse Power : 12.5 Nos. 1.00 960.89 960.89
Xiii-102 NS Connection Plate Capacity in Horse Power: 15 Nos. 1.00 1,089.01 1,089.01
Xiii-103 NS Connection Plate Capacity in Horse Power: 20 Nos. 1.00 1,089.01 1,089.01
Xiii-104 NS Connection Box Capacity in Horse Power - -
Xiii-105 NS Connection Box Capacity in Horse Power: 2 Nos. 1.00 448.41 448.41
Xiii-106 NS Connection Box Capacity in Horse Power: 5 Nos. 1.00 448.41 448.41
Xiii-107 NS Connection Box Capacity in Horse Power: 7.5 Nos. 1.00 512.47 512.47
Xiii-108 NS Connection Box Capacity in Horse Power: 10 Nos. 1.00 512.47 512.47
Xiii-109 NS Connection Box Capacity in Horse Power: 12.5 Nos. 1.00 640.59 640.59
Xiii-110 NS Connection Box Capacity in Horse Power: 15 Nos. 1.00 640.59 640.59
Xiii-111 NS Connection Box Capacity in Horse Power: 20 Nos. 1.00 768.71 768.71
Xiii-112 NS Glade Plate Capacity in Horse Power - -
Xiii-113 NS Glade Plate Capacity in Horse Power: 2 Nos. 1.00 960.89 960.89
Xiii-114 NS Glade Plate Capacity in Horse Power: 5 Nos. 1.00 960.89 960.89
Xiii-115 NS Glade Plate Capacity in Horse Power: 7.5 Nos. 1.00 1,281.19 1,281.19
Xiii-116 NS Glade Plate Capacity in Horse Power: 10 Nos. 1.00 1,537.42 1,537.42
Xiii-117 NS Glade Plate Capacity in Horse Power: 12.5 Nos. 1.00 1,537.42 1,537.42
Xiii-118 NS Glade Plate Capacity in Horse Power: 15 Nos. 1.00 1,793.66 1,793.66
Xiii-119 NS Glade Plate Capacity in Horse Power: 20 Nos. 1.00 1,921.78 1,921.78
Xiii-120 NS Glade Plate Capacity in Horse Power: 40 Nos. 1.00 1,921.78 1,921.78
Xiii-121 NS Coupling Set ( Tyre Coupling ): Capacity in Horse Power - -
Xiii-122 NS Coupling Set ( Tyre Coupling ): Capacity in Horse Power: 2 Nos. 1.00 2,562.37 2,562.37
Xiii-123 NS Coupling Set ( Tyre Coupling ): Capacity in Horse Power: 5 Nos. 1.00 3,202.96 3,202.96
Xiii-124 NS Coupling Set ( Tyre Coupling ): Capacity in Horse Power: 7.5 Nos. 1.00 3,202.96 3,202.96
Xiii-125 NS Coupling Set ( Tyre Coupling ): Capacity in Horse Power: 10 Nos. 1.00 3,587.32 3,587.32
Xiii-126 NS Coupling Set ( Tyre Coupling ): Capacity in Horse Power: 12.5 Nos. 1.00 3,587.32 3,587.32
Xiii-127 NS Coupling Set ( Tyre Coupling ): Capacity in Horse Power: 15 Nos. 1.00 3,587.32 3,587.32
Xiii-128 NS Coupling Set ( Tyre Coupling ): Capacity in Horse Power: 20 Nos. 1.00 4,484.15 4,484.15
Xiii-138 NS Silicon Seal Capacity in Horse Power: 2 Nos. 1.00 3,074.84 3,074.84
Xiii-139 NS Silicon Seal Capacity in Horse Power: 5 Nos. 1.00 4,932.56 4,932.56
Xiii-140 NS Silicon Seal Capacity in Horse Power: 7.5 Nos. 1.00 5,380.98 5,380.98
Xiii-141 NS Silicon Seal Capacity in Horse Power: 10 Nos. 1.00 5,380.98 5,380.98
Xiii-142 NS Silicon Seal Capacity in Horse Power: 12.5 Nos. 1.00 6,149.69 6,149.69
Xiii-143 NS Silicon Seal Capacity in Horse Power: 15 Nos. 1.00 7,046.52 7,046.52
Xiii-144 NS Silicon Seal Capacity in Horse Power: 20 Nos. 1.00 10,890.07 10,890.07
Xiii-145 NS Ozonator and its Parts - -
Xiii-146 NS OZONATOR: QUARTZ TUBE NOS. 12.00 12,558.81 1,50,705.73
Xiii-147 NS OZONATOR: HT Transformer NOS. 8.00 29,682.50 2,37,459.97
Xiii-148 NS OZONATOR: ozone card NOS. 8.00 27,399.23 2,19,193.82
Xiii-149 NS OZONATOR: seeds kg 100.00 7,307.13 7,30,712.59
Xiii-150 NS OZONATOR: ozone cell complete set 1.00 41,098.84 41,098.84
Supply, installation, testing and commissioning of Variable Frequency Drive (VFD) for Decanter operation of STP Plant.
Rating: 0.75 KW/1 HP
CHASSIS/IP20, IE2 2.4% Temp. 40 degree C
Sub-Total Of STP Works 1,70,37,634.68
10 DISPOSAL OF GARBAGE ETC.
"Disposal of moorum/ building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport
including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete
as per directions of Engineer-in-Charge.
Note - Item to be applicable in urban areas having directions for restricted hours for movement/plying of load carriying
motor vehicle of 3.5 cum or more." (only waste material which can not be recyled at in house Solid waste treatmnet plant
or in case SWMP is not working)
11 Day-Today CIVIL WORKS : INTERNAL & EXTERNAL FINISHING
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over
the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of
b approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 12,667.00 90.41 11,45,238.16
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of
c approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 8,176.33 135.08 11,04,428.26
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
e 13.99.1 One or more coats on old work. sqm 12,000.00 101.02 12,12,295.73
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
g 13.45 Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @
Melamine polishing on wood work (one or more coat).
signed by RAJ PAL
Finishing walls and ceiling with one or more coats of epoxy paint including surface preparation, base coat all complete as per
directions of Engineer-in-Charge
k NS Supply, painting and finishing of THERMO COOL PAINT ON OVERHEAD TANKS, complete as required Sqm 1,600.00 577.00 - 9,23,200.00
SUB TOTAL OF INTERNAL & EXTERNAL FINISHING SUB TOTAL 76,47,154.89 51,76,890.20
12 Civil works for Maintenance
Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power
pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and
consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to
centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of
cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of
angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to
which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5
mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting
12-a1 12.45.1 clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick Sqm 667.00 1,332.39 8,88,701.02
27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl
plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling
section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and
finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes ,
finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable
for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills,
diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and
direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler
false ceiling tiles of Size 595x1195 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient)
of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire
performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM
518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron
section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile
(white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length
1200 mm and secondary intermediate cross- T of size 15x42 mm of length 600mm to form grid module of size 600 x 600
mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm
outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of
size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on
periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws.
The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 26.23.1 With
15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of
the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base
of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing
12-a3 11.51.1 with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all Sqm 400.00 6,489.31 25,95,724.06
complete as specified and as directed by the Engineer-in-Charge.
18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Providing and fixing machine cut, mirror/ eggshell polished, Marble stone work for wall lining (verneer work) including dado,
skirting, riser of steps etc., in required design and pattern whenever required, stones of different finished texture, on 12mm
(average) thick cement mortar 1:3 (1cement:3 coarse sand) laid and joined with white cement slurry @ 3.3 kg/sqm
12-a4 8.11.1 including pointing with white cement slurry admixed with pigment with matching shades, including rubbing, curing, sqm 267.00 10,234.94 27,32,728.02
polishing etc. all complete as per architecutral drawings, and as directed by the engineer- in- charge.
18 mm thick italian Marble stone, Perlato, rosso verona, Fire red and Dark emperadore etc
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by
12-a5 8.31 Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sqm 100.00 1,246.05 1,24,605.25
sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of
matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water
absorption less than 0.08%and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick
12-a6 11.41.2 cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., sqm 100.00 1,526.62 1,52,662.19
Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear
portions of the building all complete as per the architectural drawings with 18 mm thick stoneslab over 20 mm (average)
12-a7 11.55.1 thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white sqm 533.00 3,131.67 16,69,177.81
cement slurry admixed with pigment of matching shade including rubbing,curing and polishing etc. all complete as specified
and as directed by the Engineer-in-Charge
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying broken glazed China mosaic tile flooring on roof/terrace, using broken glazed tiles of approved quality,
size and colour, laid over a bed of cement mortar 1:3 (1 cement : 3 coarse sand), including preparation of surface, proper
12-a8 NS slope towards outlets, filling and finishing of joints with white cement, making necessary rounding at junctions and sqm 1,200.00 1,285.00 15,42,000.00
extending the treatment up the parapet/wall as required, including all materials, labour, scaffolding, curing, cleaning and
finishing complete in all respects as per the direction of Engineer-in-Charge.
Grading roof for water proofing treatment with
12-a9 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Cum 200.00 7,903.41 15,80,681.90
Digitally signed by RAJ PAL
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with
pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1
cement : 4 coarse sand) :
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming
12-a11 10.25.2 coat of approved steel primer using structural steel etc. as required. kg 1,333.00 169.62 2,26,102.39
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block
making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern
over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the
direction of Engineer-in-charge.
Supply and laying of cobble stone size 100 x 100 x 50 mm rough surface with required cement morter 1:3 (1 cement 3
12-a13 NS coarse sand) making design as per approved sample by Engineer-in-charge Sqm 67.00 10,954.00 7,33,918.00
Providing and fixing white viterious china battery based infrared sensor operated urinal of approx. size 610x390x370 mm
having pre & post flushing with water (250ml& 500ml consumption), having water inlet from back side, including fixing to
12-a14 NS wall with suitable brackets all as per manufacturers specification and direction of Engineer- in- charge. each 100.00 15,200.50 15,20,050.00
(Reference make Jaguar Urinal, Range:Urinals, Code:URS-WHT-13263 or equivalent from other approved makes)
Providing and fixing mirror of 5.5 mm thick superior glass (of approved quality) and of required shape and size including
12-a15 NS edge grinding, making holes for fixing to the wall using SS 304 studs of 40 mm dia, of required nos@4 per Sqm sqm 200.00 5,224.00 10,44,800.00
Providing and fixing white vitreous china wall hung water closet of Jaquar-Solo- SLS-WHT-0117 OR Equivalent, including
providing & fixing concealed cistern of Grohe/Gebrit/ Jaquar with dual flush fitting of flushing capacity 3 litre/6 litre
(adjustable to 4 litre/ 8 litre ), including seat cover and cistern fitting, nuts, bolts and gasket etc. complete.
Providing and fixing of Health Faucet with metal hose and holder in polished chrome, (Hindware-F160059) or Equivalent
along with all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per
direction of Engineer-Incharge.
Providing and fixing toilet paper holder.
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated
glass (doubleglazed) vision panel units of size and shape as required and specified,comprising of an outer heat strengthened
float glass 6 mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and
shade, an inner Heat strengthned clear float glass 6 mm thick, spacer tube 12 mm wide, dessicants, including primary seal
and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural
drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be 200.00 3,654.48 7,18,273.04
assembled in the factory/ workshop of the glass processor. For payment, only the actual area of glass on face # 1 of the
glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be
measured in sqm (i) Coloured tinted float glass 6 mm thick substrate with reflective soft coating on face # 2, + 12 mm
Airgap + 6 mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of
25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U
value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning
Float glass panes
12-a20 9.7.7.2 5.0 mm thick glass panes (weight not lessthan 12.50 kg/sqm). sqm 167.00 2,555.54 4,26,775.22
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed
with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed
with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
12-a21 22.5 (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This sqm 667.00 606.39 4,04,464.50
layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface,
treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of
concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per
12-a22 NS direction of Engineer-in-charge. (The payment shall be made on the basis of actual weight of approved grout injected). a) Kg 1,333.00 1,105.00 14,72,965.00
Epoxy injection grout in concrete/RCC work of approved make. (In small patches at diffrent location)
Providing and fixing dry cladding upto 10 metre height with 30 mm thick gang saw cut stone with machine cut edges of
uniform colour and sizeupto 1mx1m, fixed to structural steel frame work and/ or with the help ofcramps, pins etc. and
12-a23 8.20.1 sealing the joints with approved weather sealantas per Architectural drawing and direction of Engineer-in-charge. (Thesteel sqm 267.00 2,852.52 7,61,623.17
frame work, stainless steel cramps and pins etc. shall be paid forseparately).
Red sand stone - 30 mm thick gang saw cut stone
Providing and applying 2.5 mm thick road marking strips (retro- reflective)of specified shade/ colour using hot thermoplastic
material by fully/ semiautomatic thermoplastic paint applicator machine fitted with profile shoe,glass beads dispenser,
12-a24 16.62 propane tank heater and profile shoe heater,driven by experienced operator on road surface including cost of Sqm 267.00 734.89 1,96,214.43
material,labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per
direction of Engineer-in-charge andaccordance with applicable specifications.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in
9.1.3 position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for cum 10.00 81,938.11 8,19,381.11
Kiln seasoned and chemically treated hollock wood
Digitally signed by RAJ PAL
Supplying, Installation, Testing and commissioning of Water Level Indicator Unit (Model - Flexibell) : Supplying display
unit of continuous wireless water level indicator with 7-segment LED display (56mm height) to indicate water level of
12-a26 NS single/ multiple tanks (Maximum 6 Tanks)in percentage with 1 % resolution. It will also indicate Flow status and audio/ each 2.00 48,268.64 96,537.29
visual alarm for Full/Low/ Overflow condition. ( Only Receiver/ Display unit without transmitters. Water level data
Transmitters unit will be charged separately) [Size in mm: 426(H) x225(W)x95(D)]
Supplying, Installation, Testing and commissioning of Digital Sump Transmitter with 25ft Sensor Length: Supplying
NS battery powered water level data transmitter with water level sensors to measure water level with 1% resolution and flow/ each 8.00 12,281.44 98,251.52
overflow status and transmit the data wirelessly to controller cum receiver unit.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block
board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or
12-a28 9.21.1 cross bands and face veneers on both faces of shutters: SQM 333.00 2,351.33 7,82,992.54
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing in wall lining medium density fibre board IS: 14587:1998 marked, Pre-laminated one side decorative
lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete.
Treatment of area for termites, pest, wood borers, rodents etc. complete as per directions of Engineer-in-Charge
Supplying and fixing of Stainless Steel trays (SS-316 Grade), minimum 1.5 mm thickness, below basement shafts and
NS expansion joints to prevent spillage of water in the basement area including all supporting arrangement like GI tie rod, sqm 67.00 3,939.64 2,63,956.14
Bullet Fasteners, Solid/Slotted GI angles for supports complete in all respect or as per direction of Engineer In-Charge.
Cleaning of Rain Water Harvesting pits by manually complete in all respect upto the satisafaction of Engineer Incharge.
Cleaning of Rain Water Harvesting pits by machine complete in all respect upto the satisafaction of Engineer Incharge.
Half brick masonry with non-modular fly ash bricks of class designation 10, conforming IS:12894, in super structure above
12-a34 6.45.2 plinth and upto floor V level. cement mortar 1:4 (1 cement : 4 coarse sand) sqm 100.00 1,086.70 1,08,670.28
SUB TOTAL OF Civil works for maintenance 1,79,61,696.19 66,34,954.55
13 Electrical Works
Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor
single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and
a 1.10.2 earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Point 50.00 1,375.62 68,781.00 -
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of
insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper
winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as
DSR FOR BLDC fans per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control
9.1.3 and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation
resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan
Supply,earthing etc. complete as req.
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
j 2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature Single Pole each 20.00 287.85 5,757.00 -
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.)
l with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the 133.00 1,67,375.18
point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor,
m 1.14.1 single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth metre 1,000.00 269.67 2,69,670.00 -
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor,
n 1.14.2 single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth metre 667.00 314.11 2,09,511.37 -
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor,
o 1.14.3 single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire metre 667.00 376.73 2,51,278.91 -
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor,
p 1.14.4 single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire metre 333.00 486.82 1,62,111.06 -
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor,
q 1.14.5 single core cable in surface/ recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire metre 333.00 627.21 2,08,860.93 -
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor,
r 1.14.9 single core cable in surface/ recessed medium class PVC conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire metre 333.00 821.13 2,73,436.29 -
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor,
s 1.14.10 single core cable in surface/ recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire metre 333.00 1,088.78 3,62,563.74 -
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor,
t 1.14.11 single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire metre 333.00 1,468.54 4,89,023.82 -
Digitally signed by RAJ PAL
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/
u 1.17.3 recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm metre 1,000.00 105.04 1,05,040.00 -
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/
v 1.17.12 recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm metre 1,000.00 149.48 1,49,480.00 -
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/
w 1.17.21 recessed steel/ PVC conduit as required. 3 x 4 sq. mm metre 1,000.00 224.22 2,24,220.00 -
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/
x 1.17.30 recessed steel/ PVC conduit as required. 3 x 6 sq. mm metre 333.00 329.26 1,09,643.58 -
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/
y 1.17.33 recessed steel/ PVC conduit as required. 6 x 6 sq. mm metre 333.00 647.41 2,15,587.53 -
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but
z 1.24.6 excluding modular plate etc. as required. Telephone socket outlet Nos. 100.00 169.68 16,968.00 -
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but
aa 1.24.7 excluding modular plate etc. as required. TV antenna socket outlet Nos. 100.00 169.68 16,968.00 -
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but
ab 1.24.8 excluding modular plate etc. as required. Bell push each 100.00 160.59 16,059.00 -
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including
ac 1.21.2 cutting the wall and making good the same in case of recessed conduit as required. 25 mm meter 667.00 169.68 1,13,176.56 -
Re-filling of all types of fire extinguishers ( e.g. 4.5kg /9 kg CO2 Type ,6kg /9 kg ABC type, 9kg water co2 type etc)
ad NS including transporation to & fro get to be done as per DFS/ manufacturers recommondations . Nos. 900.00 422.79 3,80,511.95
Telephone wiring in Existing Conduits: Supplying and drawing following pair 0.61 sq mm FR PVC insulated annealed copper
ae 1.18.2 conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair RM 500.00 39.39 19,695.00 -
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing
af 1.31 and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. each 200.00 550.45 1,10,090.00 -
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing
ag 1.32 and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. each 200.00 665.59 1,33,118.00 -
Supply & Installation of high discharge sealed maintenance free battery of 12V 12AH for Lifts/UPS inculding deduction for
ah NS unserviceable batterys (Rs.100) complete as required. each 901.00 2,049.90 - 18,46,956.30
Supply & Installation of high discharge sealed maintenance free battery of 12V 180AH for HT Panel/DGs inculding deduction
ai NS for unserviceable batteries (Rs.2000) complete as required. each 32.00 21,375.80 - 6,84,025.70
Supply & Installation of DC Power pack is used as a source of DC power in Power substations of 24V 7AH complete as
Supply & Installation of Informatory signage comprising of ACP sheet sides Facia, angle iron frame, backlit star flex, sheet in
ak NS MS tube frame having monogram and printing fix on both faces including LED module and all fixing arrangement clamp etc. sqm 20.00 8,594.19 1,71,883.78
complete at different locations at site and as per direction of EIC.
Supply & Installation of Informatory signage comprising of Acrylic signage board, both side refelctive, sheet in MS tube
al NS frame having monogram and printing fix on both faces and all fixing arrangement clamp etc. complete at different locations sqm 30.00 2,306.13 69,183.99
at site and as per direction of EIC.
Supply, Installation, Testing & commissioning of Brass Air Release Valve of 25mm.
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing
conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for
an 39.17.1 compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating meter 533.00 60.60 32,299.80 -
Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc.
complete as required.
Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting
complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,supports, bends, transitions, reducers,
30.12.2.3 end caps,collars etc as required complete in all respect in
E&M confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required.
Thickness 1.00 mm sheet
Supply of cleaner for stainless steel chrome, aluminium and metal surfaces having weight of 0.63 grams or as per direction
ap NS of EIC. (Ref make & model: 3M Stainless steel cleaner and polish or from other approved makes) Nos. 323.00 1,377.27 4,44,859.46
14 Comprehensive ARM of OF LIFTS/ELEVATORS, ETC. For 1st to 12 months
a NS Lifts in Office Blocks 1 to 4 (44 nos) Per Month 12.00 9,64,187.24 1,15,70,246.82
Digitally signed by RAJ PAL
b NS Exhibition Centre Lifts (3 nos) Per Month 12.00 36,418.06 4,37,016.67
Comprehensive ARM of OF LIFTS/ELEVATORS, ETC. For 13th to 24th month
c NS Lifts in Office Blocks 1 to 4 (44 nos) Per Month 12.00 10,12,396.60 1,21,48,759.16
d Ns Exhibition Centre Lifts (3 nos) Per Month 12.00 40,059.86 4,80,718.34
Comprehensive ARM of OF LIFTS/ELEVATORS, ETC. For 25th to 36th month
e NS Lifts in Office Blocks 1 to 4 (44 nos) Per Month 12.00 10,63,016.43 1,27,56,197.12
f NS Exhibition Centre Lifts (3 nos) Per Month 12.00 44,065.85 5,28,790.17
SUB TOTAL OF ARM OF Lifts Total - 3,79,21,728.30
15 AMC of GG SETS
a NS 1450 KVA GG SETS for 1st month to 12th month Per Month 12.00 4,55,714.53 54,68,574.30
b NS 720 KVA GG SETS for 1st month to 12th month Per Month 12.00 62,569.50 7,50,834.00
d NS 1450 KVA GG SETS for 13th month to 24th month Per Month 12.00 4,78,500.25 57,42,003.02
e NS 720 KVA GG SETS for 13th month to 24th month Per Month 12.00 65,697.98 7,88,375.70
g NS 1450 KVA GG SETS for 25th month to 36th month Per Month 12.00 5,02,425.26 60,29,103.17
h NS 720 KVA GG SETS for 25th month to 36th month Per Month 12.00 68,982.87 8,27,794.49
Sub Total of GG sets AMC 1,96,06,684.67
16 CAMC for Boom Barrier
Comprehensive AMC Charges for Boom Barrier 20 Nos., Controller 14 Nos., Long Range Reader 14 Nos., with Photocell and
a NS Push Button and Other Accessories for 1st month to 12th month. Per Month 12.00 95,557.39 11,46,688.70
Comprehensive AMC Charges for Boom Barrier 20 Nos., Controller 14 Nos., Long Range Reader 14 Nos., with Photocell and
b NS Push Button and Other Accessories for 13th month to 24th month. Per Month 12.00 98,424.11 11,81,089.36
Comprehensive AMC Charges for Boom Barrier 20 Nos., Controller 14 Nos., Long Range Reader 14 Nos., with Photocell and
d NS Push Button and Other Accessories for 25th month to 36th month. Per Month 12.00 1,01,376.84 12,16,522.04
Comprehensive AMC Charges for Flap Barrier P Type/Automatic Door/Access Control Installed at Office Block site for 1st
e NS month to 12th month. Per Month 12.00 2,08,385.74 25,00,628.86
Comprehensive AMC Charges for Flap Barrier P Type/Automatic Door/Access Control Installed at Office Block site for 13th
g NS month to 24th month. Per Month 12.00 2,14,637.31 25,75,647.73
Comprehensive AMC Charges for Flap Barrier P Type/Automatic Door/Access Control Installed at Office Block site for for
h NS 25th month to 36th month. Per Month 12.00 2,21,076.43 26,52,917.16
Comprehensive AMC Charges for ANPR System with accessories for 1st month to 12th month.
Comprehensive AMC Charges for ANPR System with accessories for 13th month to 24th month.
Comprehensive AMC Charges for ANPR System with accessories for 25th month to 36th month.
Sub Total CAMC for Boom Barrier, Flap Barrier & ANPR Cameras
Comprehensive Annual Maintenance Contract (CAMC) for Chiller Plants
Comprehensive AMC For Chiller, Model No: PFS2202DARY of 6 nos. qty. for 1st 12 months (Tower 3 & 4)
Comprehensive AMC For Chiller, Model No: PFS3703DARY of 4 nos. qty. for 1st 12 months (Tower 1)
Comprehensive AMC For Chiller, Model No: SA5E01C01V4BXA-WSC087M of 4 nos. qty. for 1st 12 months (Tower 2)
Comprehensive AMC For Chiller, Model No: PFS2202DARY of 6 nos. qty. for 13 to 24 months (Tower 3 & 4)
Comprehensive AMC For Chiller, Model No: PFS3703DARY of 4 nos. qty. for 13 to 24 months (Tower 1)
Digitally signed by RAJ PAL
Comprehensive AMC For Chiller, Model No: SA5E01C01V4BXA-WSC087M of 4 nos. qty. for 13 to 24 months (Tower 2)
Comprehensive AMC For Chiller, Model No: PFS2202DARY of 6 nos. qty. for 25 to 36 months (Tower 3 & 4)
Comprehensive AMC For Chiller, Model No: PFS3703DARY of 4 nos. qty. for 25 to 36 months (Tower 1)
Comprehensive AMC For Chiller, Model No: SA5E01C01V4BXA-WSC087M of 4 nos. qty. for 25 to 36 months (Tower 2)
Sub Total CAMC Chiller plats
Providing services of Watch & Ward at required locations round the clock with all requisite accessories etc complete in all
a NS respect or as per direction of Engineer Incharge. Per Month 36.00 25,49,980.17 9,17,99,286.20
D Special Repair
19 Special Repair works
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power
driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including
19-a1 NS cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts Sqm 4,000.00 332.00 13,28,000.00
all complete as per direction of Engineer-In- Charge (In small patches at diffrent location)
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline
chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with
19-a2 NS wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Metre 26,667.00 12.00 3,20,004.00
Bars upto 12 mm diameter (In small patches at diffrent location)
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and
direction of Engineer-in-charge complete in all respect. a) Epoxy bonding adhesive having coverage 2.20 sqm/kg of
19-a3 NS approved make. (In small patches at diffrent location) Sqm 4,000.00 54.00 2,16,000.00
Polymer Modified Mortar for Cracked & Spalled Portions: Building up the profile of structural members 10/25/50 mm
average depth by using emulsified SBR latex having solid content not less than 40% and conforming to ASTM C-10 59
Type1/Type-II in dam aged areas (1 Cement-3 part graded cleaned river sand + 20% latex by weight of cement) with 0.35
w/c ratio, in maximum 15- 20 mm thick layers wise providing SBR bond coat in between successive layers, including
19-a4 NS leveling profiling complete. Proper moist curing to be done for the repair work. Gunny bags may be used for effective Sqm 4,000.00 2,306.00 92,24,000.00
curing. Polypropylene fibers to be added to reduce shrinkage. For measurement, patch area of repair work will be taken.
(SBR bond coat will be paid separately) (Specification meeting ASTM C-1059 shall approved by EIC before application), ali
complete as per direction of Engineer In-Charge (a) 25 mm average thickness (In small patches at diffrent location)
Providing and fixing double scaffolding system (cup lock type) made with 40 mm dia M.S. tube 1.5 m centre to centre,
horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S.
staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required
duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings,runners,
19-a5 NS connection with the building etc wherever required for inspection of work at required locations with essential safety features Sqm 4,667.00 498.00 23,24,166.00
for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding
shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.
Providing and laying in position free flow high strength non shrink micro-concrete M-40 using single component cement
micro concrete added with 6 mm down size aggregate in the ratio of 1-part micro concrete with 0.3 part of aggregate by
weight. Water cement ratio shall be maintained properly as per manufacturers specifications to achieve dense soild mass
19-a6 NS prepared micro concrete shall be poured properly and curing the micro concrete thoroughly for 14 days cost inclusive of Cum 37.00 53,810.00 19,90,970.00
curing etc. complete all as directed at site by Engineer-in-charge (in small patches at different location)
Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper
shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing
19-a7 14.75 mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. Sqm 1,000.00 659.36 6,59,362.69
Supply and installation of Sensor taps as per approved sample including required size and shape of base plate including
cutting and making good the surface complete. (Make: Plumber Bathware, Euronics or equivalent)
Digitally signed by RAJ PAL
Supplying Installation Testing and Commissioning of 4MP IP IR Dome Camera having following specifications and features
etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live
& recorded video 2)Image Sensor: 1/2.8" or better progressive Scan CMOS to get color image even at night
condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance
Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto
50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain
Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking 3)
Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic
Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple
streaming , configurable Main stream: 4MP (2560×1440)25/30fps , Sub streams minimum: 720P@25/30 fps 7) Image
Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge
Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption,
19-a9 40.3.2 trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Each 33.00 23,991.54 7,91,720.82 -
Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with
minimum 128GB memory 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards:
BIS with ER, STQC Certified, CE, FCC and RoHS Card. 10) Recording Management: Format SD, overwrite, storage
management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4,
DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System
Capability: ONVIF, Camera shall support open source VMS
14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External
Mic. and Speakers as per site requirement.
16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE
(802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24
VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10,
Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and
features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB,Camera should display Camera title, Date &
Time in live & recorded video 2)Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night
condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance
Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto
50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain
Control, White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3)
Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic
Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 3) Compression (Minimum): Video:- H.265 or
better, 16) Power Input: The camera should support 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8
MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS simultaneous dual power input—12 VDC (via
power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power
Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19)
Operating Condition:- Ambient Temperature:- ( )05°C to 50°C, humidity 95% (max) (non-condensing) Audio:- G.711U/A,
G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D)
On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps , Sub
streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable
through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-
bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC
19-a10 40.4.2 filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot Each 7.00 23,991.54 1,67,940.78 -
upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite,
storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection
detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6,
IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13)
System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio :
It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 6) Video
Streaming & Frame Rates :- Triple streaming, configurable Main stream: 4MP (2560×1440)25/30fps Sub streams
minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through
client software or web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection 8) Cyber Security: AES 256-bit
Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC
filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot
upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite,
storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection
detection; IP conflict detection; memory card state detection; memory space detection 12) Network Protocol: SFTP, IPv6,
IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13)
System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio :
It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power
Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to
ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE
16 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
Digitally signed by RAJ PAL
Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses
to record for all channels having specifications and features etc as mentioned below :
1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a
live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum
support of 384 Mbps incoming Bandwidth. 2) NVR should support video compressions : H.265 or better, H.264, MJPEG. 3)
Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio
compressions. 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support
minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x
10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port 7) Backup Interface : Its should have 4 Nosx USB
port (2x USB3.0, 2xUSB2.0) 8) Video Output Ports: 2x HDMI and 2 VGA. 9) Alarm Ports: It should have 16/8 Ch In/ Out
ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options:
Option for SMS/Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring,
network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for
alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP,
DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM
Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified. 14) Power Supply :
Should support AC100-240V, 50/60Hz Power supply. 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-
condensing). 16) The VMS application shall support all the features & functionalities of the offered cameras. 17) VMS should
consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording
modes. VMS should be provided with Camera Licenses, with no dependency of VMS licenses by binding with the MAC
address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application
19-a12 40.11 compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The
OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring
over the Internet. 20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode. 21) It should support
Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF. 22) When alarm recording is enabled
and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is
supported on monitoring and playback page. 23) The Network Video Recorder (NVR) shall be configured to send email
whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each
recipient email address shall be configured to receive any combination of critical, warning, or informational messages or
alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera
that is configured to record upon alarm. 24) It should have Web and GUI interface. .25) Built-In Artificial Intelligence: NVR
should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum
8 Channel Smart Motion Detection. 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist
capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name,
gender, birthday, address, credential type, credential No., countries & regions and state to each face image. 27) Face &
Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color,
top type, hat, bag, age, gender and umbrella. 28) ANPR Capability: It should support ANPR Camera with License plate, plate
color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 29)
Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external
alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo
analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity
exception 30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs,
presets and email. 31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall
32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen:
Supplying, Installation, Testing and Commissioning following capacity Surveillance grade Hard Disk with upto 256MB/s
Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE,
19-a14 40.12.3 FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. Each 13.00 20,320.19 2,64,162.47 -
8TB (Terabytes)
Online UPS - Input supply: Single Phase, Output Supply: Single Phase. Supplying, installation, Testing & Commissioning of
following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single
Phase input,Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes
back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load
(Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable
isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based
Digital Control, using Insulated Gate BipolarTransistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width
Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-
national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear
loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100
%load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to
0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable
to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase160-
270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload
capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non
condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output
voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for
watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC)
achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as
per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/
RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC
breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required
Digitally signed by RAJ PAL
Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation, Testing & Commissioning of
following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online
double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules
without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number
of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes
back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load
(Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable
isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction.
The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation
using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width
Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national
standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery
mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid
shall be <5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost),
extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity
(i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading
power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output
19-a18 DSR 26.2 voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing,
noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery
over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must
comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall
be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for
BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required
battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are
inclusive of the cost). This system must providea means for logging and alarming of all monitored points plus email
notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least
80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242
and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage,
current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity.
e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS
should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-
circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to
Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS
Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure,
Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over,
19-a19 26.2.1 10KVA (Each Power module shall be < 10 KVA) each 3.00 2,10,981.93 6,32,945.79 -
19-a20 26.2.2 20KVA (Each Power module shall be < 10 KVA) each 8.00 3,45,189.72 27,61,517.76 -
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589
19-a21 27.7 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling
with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade
complete as required :
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm
19-a25 27.9 dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as
19-a26 27.9.2 Single headed Stainless steel each 10.00 6,698.32 66,983.20 -
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless
19-a27 27.10 Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap
and chain as required :
19-a28 27.10.2 Single headed Stainless steel each 10.00 6,698.32 66,983.20 -
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked
19-a29 27.11 complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with
19-a39 27.14 rubber gasket, GI bolts, nuts, washers etc.as required :
Digitally signed by RAJ PAL
Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding,
fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable
19-a49 27.8.6 clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required meter 200.00 1,529.14 3,05,828.00
Supply installation testing commissioning of Stainless Steel Monobloc (pump and motor) set, 3 HP, Three Phase, 415 Volts,
19-a50 NS Size 50 mm X 32 mm for water supply with all fittings and accessories complete as required. (Ref make Kirloskar, model: Set 2.00 81,114.00 1,62,228.00
ETERNA KSMB 324 or equivalent from approved makes)
LED Down lighter (SMD Type) (System lumen Unit Rate efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing &
Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material
with PMMA andprismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver
efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal
surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR
(Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of
minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K /
19-a51 8.1 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption
should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word
Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with
1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5
year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing
required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge
as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not
rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim.
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of
Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with
Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to
40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,
UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of
minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-
21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour
Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS
standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c
external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.
as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test
report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved
by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED
junction temperature shall not rise
19-a54 8.6.3 above
22 Watt90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) each 33.00 2,393.70 78,992.10 -
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED
surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per
the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp
19-a55 8.9 range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20,
CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000
Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI
Bin), SDCM(Standard Deviation.
19-a57 NS MOTOR & PUMP REPAIRING ITEMS
19-a58 S.NO. 7.5 H.P Pump & Motor Repairing Vertical type
19-a59 a. Mechanical Seal Nos. 12.00 9,609.00 1,15,308.00
19-a62 d. Diffuzer Repair Nos. 15.00 1,281.00 19,215.00
19-a64 f. Impeller Repair Nos. 15.00 897.00 13,455.00
19-a66 h. Pump Opening Fitting and Alignment Charges Nos. 12.00 5,765.00 69,180.00
19-a67 i. Motor Rewinding Nos. 3.00 8,968.00 26,904.00
19-a69 k. Motor Opening Fitting and Alignment Charges Nos. 12.00 4,484.00 53,808.00
19-a70 15 H.P Pump & Motor - -
19-a71 a. Mechanical Seal Nos. 12.00 8,328.00 99,936.00
19-a74 d. Pump Opening Fitting and Alignment Charges Nos. 6.00 5,765.00 34,590.00
19-a75 e. Motor Rewinding Nos. 6.00 12,812.00 76,872.00
19-a77 g. Motor Opening Fitting and Alignment Charges Nos. 6.00 4,484.00 26,904.00
19-a79 20 H.P Pump & Motor -
19-a80 a. Mechanical Seal Nos. 8.00 8,328.00 66,624.00
19-a82 c. Neck Ring (Bronze) Nos. 8.00 5,765.00 46,120.00
19-a83 d. Pump Opening Fitting and Alignment Charges Nos. 4.00 5,765.00 23,060.00
19-a84 e. Motor Rewinding Nos. 4.00 15,374.00 61,496.00
19-a86 g. SS sleeve Digitally Nos. 4.00
signed by RAJ PAL 3,587.00 14,348.00
19-a87 h. Motor Opening Fitting and Alignment Charges Nos. 5.00 4,484.00 22,420.00
19-a88 25 H.P Pump & Motor - -
19-a89 a. Mechanical Seal Nos. 8.00 8,328.00 33,312.00
19-a91 c. Neck Ring (Bronze) Nos. 8.00 5,765.00 23,060.00
19-a92 d. Pump Opening Fitting and Alignment Charges Nos. 4.00 5,765.00 23,060.00
19-a93 e. Motor Rewinding Nos. 4.00 16,015.00 1,28,120.00
19-a96 h. Motor Opening Fitting and Alignment Charges Nos. 4.00 4,484.00 35,872.00
19-a97 30 H.P Pump & Motor - -
19-a98 a. Mechanical Seal Nos. 8.00 8,328.00 66,624.00
19-a101 d. Pump Opening Fitting and Alignment Charges Nos. 4.00 5,765.00 46,120.00
19-a102 e. Motor Rewinding Nos. 4.00 17,937.00 71,748.00
19-a105 h. Motor Opening Fitting and Alignment Charges Nos. 8.00 4,484.00 35,872.00
19-a106 50/60 H.P Pump & Motor - -
19-a107 a. Mechanical Seal Nos. 8.00 9,993.00 39,972.00
19-a110 d. Pump Opening Fitting and Alignment Charges Nos. 8.00 5,765.00 23,060.00
19-a111 e. Motor Rewinding Nos. 4.00 35,873.00
19-a114 h. Motor Opening Fitting and Alignment Charges Nos. 4.00 4,484.00 17,936.00
19-a115 100 H.P Pump & Motor - -
19-a116 a. Mechanical Seal Nos. 4.00 9,993.00 39,972.00
19-a119 d. Pump Opening Fitting and Alignment Charges 4.00 5,765.00
19-a123 h. Motor Opening Fitting and Alignment Charges Nos. 6.00 25,624.00 1,53,744.00
19-a124 Diesel Engine and (Fire Pump 102 HP)
19-a125 a. Mechanical Seal each 3.00 20,499.00 61,497.00
19-a126 b. Bearing 102 HP Fire diesel Pump 4.00 38,051.00 1,52,204.00
19-a129 e. Pump Opening Fitting and Alignment Charges Nos. 5.00 10,249.00 51,245.00
19-a130 f. Fire DG B-Check and complete servicing on yearly basis as required Nos. 5.00 96,089.00 4,80,445.00
19-a131 Sump Pump 2 H.P- 3 H.P - -
19-a132 a. Motor Rewinding Nos. 5.00 3,203.00 16,015.00
19-a133 b. Mechanical Seal Nos. 5.00 3,075.00 15,375.00
19-a139 h. Impeller & Body Repair Nos. 5.00 2,562.00 12,810.00
19-a140 i. Pump Opening Fitting and Alignment Charges Nos. 5.00 3,203.00 16,015.00
19-a141 Sump Pump 5.H.P Dewatering Pump - -
19-a142 a. Motor Rewinding Nos. 4.00 6,406.00 25,624.00
19-a143 b. Mechanical Seal Nos. 4.00 4,933.00 19,732.00
19-a148 g. Pump Opening Fitting and Alignment Charges Nos. 4.00 3,844.00 15,376.00
19-a149 20 HP High Pressure Horizontal Pump
19-a150 a. Mechanical Seal Nos. 4.00 4,869.00 19,476.00
19-a154 e. Pump Opening Fitting and Alignment Charges Nos. 4.00 5,765.00 23,060.00
19-a155 20 HP High Pressure Pump Vertical Type - -
19-a156 a. Mechanical Seal Nos. 4.00 14,734.00 58,936.00
19-a159 d. Diffuser Repair Nos. 4.00 1,281.00 5,124.00
19-a161 f. Impeller Repair Nos. 4.00 1,281.00 5,124.00
19-a162 g. Bearing with silicon driver Nos. 4.00 26,905.00 1,07,620.00
19-a164 i. Pump Opening Fitting and Alignment Charges Nos. 4.00 5,765.00 23,060.00
19-a165 NS Supply and laying of 3 mm thick 11KV grade rubber Mats as per IS 15652 of size 1000mmX2000mm NO 30.00 1,800.00 54,000.00
Digitally signed by RAJ PAL
Supply & Installation of Metallic Exhaust Fan of 450mm. Ref make Havells, Model: Turboforce Plus Exhaust Fan or
19-a166 equivalent from other approved makes)
Supplying, Installation, Testing and commissioning of Non-clog fully automatic Dewatering (Sewage) Pump, 5 HP,
Three Phase, 415 Volts, Size 65mm. Handling type of Screened sewage, Raw sewage' Contaminated effluents, Industrial
waste water, Storm water, Trench and tunnel water, Drain water, mine water, etc. Motor is dry type submersible and cooled
by liquid being handled. Motors are air tested for leakfree operation. Degree of protection for motor is IP68 as per IS:2147
19-a167 Non-DSR Class of insulation : F, Voltage : 415V 10%, Frequency : 50 Hz. 5%, Type of starting : As per requirement (DOL/Star Set 8.00 86,187.88 6,89,503.02
Delta/ATS), Non-clog two vane or single vane enclosed impeller, Permissible solid size up to 40 mm, Gland
packed/mechanical seal, 50 HZ/60 HZ availability , Delivery size up to 65 mm, Capacity up to 720 m3/hr, Head up to 25
metres. ( reference make: Kirloskar model ETERNA 3700 CW+ or equivalent from approved makes), Minimum Capacity -
1200 LPM, Minimum Head - 25 Mtr, Minimum Power - 5HP/3.7 KW
Supply, Installation, Testing & Commissioning of 5 Star rated enery efficient Inverter Split AC with all length piping,
insulation, fitting, drainage pipe and other accessories in all respect (Ref Model: Hitachi 2 Ton 5 Star ice Clean Xpandable
Plus Inverter Split AC (100% Copper, Dust Filter, 2024 Model, Yoshi 5400FXL, R32-RAS.G522PCAISF, Dual Platinum).
19-a168 Non-DSR Note: After installation Maintenance/repairing/repalcement of AC unit having same capacity/specification shall be under Nos. 7.00 73,014.73 5,11,103.13
scope of contractor for which no extra payments shall be paid by the department.
INTELLIGENT FIRE ALARM SYSTEM
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm
panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including
detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320
character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile
19-a169 Non-DSR memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries
with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless
integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and
shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus
over IP complete as per specifications.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with
19-a171 28.2.4 mounting base complete as required. each 133.00 3,034.04 4,03,527.32
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED,
19-a172 28.2.5 metallic cover complete with all connections etc as required. each 50.00 309.06 15,453.00
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed
19-a175 28.2.9 tempreature thermistor complete with base as required. each 20.00 2,894.66 57,893.20
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
19-a177 Supplying, installation, testing & commissioning of addressable phone control module complete as required. . 3,466.32
19-a178 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 4,103.63
19-a179 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required 3,718.82
19-a180 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as 86,304.50
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor
having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR)
19-a181 28.5.1 insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. Metre 667.00 389.86 2,60,036.62
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface /
recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
19-a182 28.5.3.2 speaker cable Two pair, 2-core, 1.5 sqmm Metre 500.00 97.97 48,985.00
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 Degree C with required
accessories: Pendent Sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 Degree C with required
accessories: Upright Sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 Degree C with required
accessories: Horizontal side wall sprinkler
Digitally signed by RAJ PAL
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 Degree C with required
accessories: Concealed Sprinkler
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT
on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet)
NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket,
stockbar of following sizes complete as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not
19-a188 less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended
from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as
19-a189 4.6.1 100 mm width X 50 mm depth X 1.6 mm thickness Metre 50.00 761.54 38,077.00
19-a190 4.6.2 150 mm width X 50 mm depth X 1.6 mm thickness Metre 50.00 811.03 40,551.50
19-a191 4.6.3 225 mm width X 50 mm depth X 1.6 mm thickness Metre 50.00 1,000.91 50,045.50
19-a192 4.6.4 300 mm width X 50 mm depth X 1.6 mm thickness Metre 50.00 1,072.62 53,631.00
19-a193 4.6.5 375 mm width X 50 mm depth X 2.0 mm thickness Metre 50.00 1,335.22 66,761.00
19-a194 4.6.6 450 mm width X 50 mm depth X 2.0 mm thickness Metre 50.00 1,453.39 72,669.50
19-a195 4.6.7 600 mm width X 50 mm depth X 2.0 mm thickness Metre 50.00 1,944.25 97,212.50
Supplying, Installation, Testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high
19-a196 7.1 performance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 each 144.00 4,944.96 7,12,074.24
meter and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc.
complete as required.
Supplying, Installation, Testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day
light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy
19-a197 7.2 detection.) having high performance, regulating programmable suitable for connected load upto 10Amp , for mounting each 85.00 9,766.70 8,30,169.50
height up to 3 mtr and for 5 m diameter coverage area along with necessary fixing
arrangements i/c programming at site etc. complete as required.
Supplying, Installation, Testing and commissioning of Microwave technology based occupancy sensor having high
performance, non programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 meter and
for 5m X 20m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as
Providing, supplying, installing, testing and commissioning of 80-inch (minimum) LED Smart TV of reputed make, having
latest specifications, 4K Ultra HD resolution (3840 × 2160 pixels), high-quality display with HDR support, minimum 120 Hz
refresh rate, advanced picture processing, built-in Wi-Fi and Bluetooth, Smart TV operating system, screen mirroring/casting
19-a199 NS facility, minimum 4 HDMI inputs including HDMI 2.1 with eARC, minimum 2 USB ports, LAN/Ethernet connectivity, built-in Each 1.00 4,80,444.00 4,80,444.00
high-quality stereo speakers with Dolby Audio/DTS or equivalent, and all other standard/latest connectivity features.
Complete with remote control, wall-mounting bracket, power cable, necessary accessories, installation and commissioning,
complete in all respects as per the direction of Engineer-in-Charge.
Providing, supplying, installing, testing and commissioning of professional LED display data splitter/distributor, suitable for
distribution of the same video/data signal to multiple LED displays, supporting required resolution and refresh rate, with
multiple output ports, HDMI/DVI/DP input-output as required, signal amplification/re-generation, EDID management,
19-a200 NS cascading facility, rack/table mounting accessories, power supply, interconnecting cables, connectors and all necessary each 2.00 7,687.00 15,374.00
accessories, complete in all respects as per direction of Engineer-in-Charge.
Sub Total of Special Repair Items 1,80,34,732.05 2,38,29,179.12
Digitally signed by RAJ PAL
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
NIT.pdf
Tender Document
SCC.pdf
Tender Document
List of Approved Makes.pdf
Tender Document
Scope of Works.pdf
Tender Document
Integrity Pact.pdf
Tender Document
GCC WITH AMENDMENTS.pdf
Tender Document
BOQ .pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .