Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.5 L+₹28,870 (9.11%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹4.8 L+₹1.6 L (50.3%)Rejected-Finance | L3 | Rejected-Finance Third Lowest |
Tender Value
₹3.5 L
EMD Value
₹8,694
Closing Date
11 Feb 2019, 5:00 pmClosed
Executive Engineer
Office of the Executive Engineer PWD Electrical Division Thiruvananthapuram
Supply and renewing damaged AC unit in Cytology Lab and FNAC lab providing additional electrical installation in the Medical College Hospital , Vandanam Alappuzha
2019_PWD_265374_1
EDT.ET.26/19
Open Tender
Electrical Works
Item Rate
20 days
MCH Vandanam
Please refer Tender documents.
5 documents required · 5 mandatory
₹784
Executive Engineer
₹8,694
6 Jan 2020
1 Feb 2019
15 Feb 2019
1 Feb 2019
11 Feb 2019
1 Feb 2019
1 Feb 2019 - 11 Feb 2019
Amount
od161408/2018_2019 : Supply installation testing and commissioning of the following capacity single phase 5 star rating wall mounting type split air conditioner unit fitted with hermetically sealed compressor, operation on refrigerant R22/Non CFC Suitable for wall/floor mounting conforming to IS 1391 (part II) (amendments - I except Power consumption norms) suitable for operation on 230 V, 50 HZ Single phase AC Supply of performing.:- a. Cooling b. Dehumidifying. c. Air Circulating. d. Filtering. e. Higher Energy Efficient. f) Copper Condensing coil , g) White/ off-white :-1.5TR single phase split AC unit including copper pipe connection, electric cabling from out door to indoor unit upto 3 meter complete (including Stand) ( Blue star/ Voltas/ Equivalent)
od161410/2018_2019 : SITC of wall mounting type 2 TR , 3 Star rated split type air conditioner unit confirming to IS 1391(Part 2) with up to date amendments, suitable for 230V, 50 Hz single phase AC supply, shall be capable of performing the functions as cooling, dehumidifying, air circulating and filtering. The air conditioners shall be complete with automatic temperature control and cut-in and cutout etc. for temperature range 16 to 30 degreeC. Outdoor unit of the air conditioners shall be fitted with hermetically sealed discharge cooled type rotary compressor operating on Eco-Friendly R32 / R410A Refrigerant with Anti-Corrosive Copper Condenser and the outer body of the unit shall be powder- coated. It shall be equipped with overload protection and shall be mounted on resilient mountings for quiet operation. (The rate is inclusive of charges for 3 m copper refregerant piping , 5m power Cables, 3m drain pipe and company make stand for ODU). Voltas or Blue star or equivalent
od161412/2018_2019 : Supply of 4 KVA automatic voltage stabilizer for A/C unit with input voltage 170 - 270 V and output 210 -230 V with overload protection (cut off), time delay, indicator, chord wire etc., as required.
od161414/2018_2019 : Supply of 5 KVA automatic voltage stabilizer for A/C unit with input voltage 170 - 270 V and output 210 -230 V with overload protection (cut off), time delay, indicator, chord wire etc., as required.
od161416/2018_2019 : Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge
od161418/2018_2019 : Dismantling the existing indoor and out door unit 1 TR/1.5TR/2TR/2.5TR/3TR and conveyance to store
od161422/2018_2019 : supply and installation for the Out door unit stand of Single phase 1 TR/1.5 TR/2TR/3TR Wall mounting split A/C unit.
od165836/2018_2019 : Supply and fixing 25 mm PVC drain pipe in position etc as required
PONNU HYLINE
cristalcool
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_361483.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .