Executive Engineer, Kamdhenu University Gandhinagar
Construction of VCC Department for Veterinary Science College, Kamdhenu University at Navsari
278608
EE-04/2025-26
Open
Civil Works
Works
Gandhinagar
3 documents required · 3 mandatory
₹6,000
Yes
Kamdhenu University Fund Account
₹3.3 L
Yes
21 Feb 2026
21 Feb 2026
21 Feb 2026
13 Mar 2026
21 Feb 2026
Name of work : Construction of VCC department for Veterinary science collage at kamdhenu university Navsari
Index Of Specification
Architect : Earth Foundation
Sr. Description of Item Volume no Page no as item no as Remark
standard standard
specification specification
booklet booklet
1 Excavation for foundation upto 1.5 m depth Building 22 4.0.0 A
including sorting out and stacking of useful work
materials and disposing off the excavated stuff Specification
upto 50 Meter lead.(A) Loose and soft soil Booklet
2 Excavation for foundation for depth from 1.5 m to Building 25 4.0.0.1 (B)
3.0 m including sorting out and stacking of useful work
materials and disposing off the excavated stuff Specification
upto 50 Meter lead.(B) Dense or Hard soil Booklet
3 Providing and laying rubble for appron (eachstone As per Approved
weighting not less than 40Kg.) including and Separate Quality
packing and filing in the interestices with quarry- sheet
spalls. Attached
4 Providing and laying cement concrete 1:2:4 (1- Building 40 5.3.13.
Cement : 2- Coarse sand : 4- graded stone work
aggregates 20 mm nominal size) and curing Specification
complete excluding cost of formwork in (A) Booklet
Foundation and Plinth
5 Providing and laying cement concrete 1:3:6 (1- Building 30 5.3.2(A)
Cement :3- coarse sand : 6- hand broken stone work
aggregates 40 mmnominal size) and curing Specification
complete excluding cost of formwork in (A) Booklet
Foundation and Plinth
6 Filling available excavated earth (excluding rock) in Building 27
trenches , plinth , sides of foundations etc. in layers work
not exceeding 20 cm in depth consolidating each Specification
deposited layer by ramming and watering. Booklet
7 Filling in foundation and plinth with sand under Building 35
floor including watering ,ramming and work
consolidating and dressing etc complete as directed Specification
by Engineer in charge Booklet
8 Filling in foundation and plinth with murrum or Building 35 4.0.0.4.
selected soil in layers of 20cm. thickness including work
watering, ramming and consolidating etc. Specification
complete. Booklet
9 Providing & laying controlled cement concrete M - Building 40, 54, 37 5.8.3, 9.1,
250 RCC work with curing etc. complete including work C
the cost of form work but excluding the cost of Specification
reinforcement for R.C.C. Work in foundation Booklet
10 Providing & laying controlled cement concrete M - Building 40, 54, 37 5.8.3, 9.1,
250 RCC work with curing etc. complete including work C
the cost of form work but excluding the cost of Specification
reinforcement for R.C.C. Work in column up to pl. Booklet
11 Providing & laying controlled cement concrete M - Building 40, 54, 37 5.8.3, 9.1,
250 RCC work with curing etc. complete including work C
the cost of form work but excluding the cost of Specification
reinforcement for R.C.C. Work in column up to all Booklet
floor with any lead and lift
12 Providing and laying controlled cement concrete Building 40, 54, 37 5.8.3, 9.1,
M:250 RCC and curing complete including the cost work H
of form work but excluding the reinforcement for Specification
reinforced concrete work in tie beam , ground Booklet
beam as directed by engineer incharge.
13 Brick work using common burnt clay building bricks Building 43, 46 6.12(B)
having crushing strength not less than 35 work
kg./Sq.Cm. in foundation and plinth in Cement Specification
Mortar 1:5. (1- Cement : 5 -fine sand)(B) Booklet
14 Providing and laying controlled cement concrete Building 40, 54, 37 5.8.3, 9.1,
M:250 RCC and curing complete including the cost work H
of form work but excluding the reinforcement for Specification
reinforced concrete work in coping/RCC bend as Booklet
directed by engineer incharge.
15 Masonary work using Aerated light weight concrete As per Approved
block having crushing strength not less than 35 Separate Quality
kg/sqcm for super structure above plinth level upto sheet
floor two level in cement mortar 1:5 ( 1 cement : 5 Attached
fine sand ) complete as per Technical Specification
16 Half brick masonry in common brunt clay building Building 54 6.30.1 (A)
bricks having crushing strength not less than 35 work
kg/Sq.cm in cement mortar 1 : 4 ( 1 cement : 4 Specification
coarse sand ) in foundation and plinth. extra for Booklet
half brick masonry in super structure above plinth
level up to floor two level. (B) conventional
17 Providing and laying controlled cement concrete Building 40, 54, 37 5.8.2, 9.1,
M:200 RCC and curing complete including the cost work H
of form work but excluding the cost of Specification
reinforcement for reinforced concrete work in Booklet
Lintel/Sill RCC Bend up to all floors with all lead and
lift as directed by engineer incharge.
18 Providing and laying controlled cement concrete Building 40, 54, 37 5.8.2, 9.1,
M:200 RCC and curing complete including the cost work H
of form work but excluding the reinforcement for Specification
reinforced concrete work in Slab level beam up to Booklet
all level with all lead and lift as directed by
engineer incharge.
19 Providing and laying controlled cement concrete Building 40, 54, 37 5.8.2, 9.1,
M:200 RCC and curing complete including the cost work B
of form work but excluding the reinforcement for Specification
reinforced concrete work in Slab up to all level Booklet
with all lead and lift as directed by engineer
20 Providing and laying controlled cement concrete M: Building 40, 54, 38 5.8.2, 9.1, l
200 RCC and curing complete including the cost of work
form work but excluding the reinforcement for Specification
reinforced concrete work in projection /Whether Booklet
shed Cantilevers up to floor two level with all lead
and lift as directed by engineer incharge.
21 Providing and laying controlled cement concrete M: Building 40, 54, 37 5.8.2, 9.1,
200 RCC and curing complete including the cost of work M
form work but excluding the reinforcement for Specification
reinforced concrete work in RCC Staircase Booklet
Cantilevers up to floor two level with all lead and
lift as directed by engineer incharge.
22 Providing TMT Bar FE 500/500D reinforcement for As per Approved
R.C.C. work including bending, binding and placing Separate Quality
in position complete upto floor two level. sheet
23 Providing 15mm thick cement plaster in single coat Building 105, 106 17.58 (II) +
on Rough (Similar)side of single or half brick walls work 17.69 The
for interior plastering upto floor two level and Specification thickness
finished even and smooth in (ii) Cement mortar 1:4 Booklet of plaster
(1-cement :4-sand) shall be
24 Providing 10 mm thick mala cement plaster in Building 105, 106 17.57 (II) +
single coat on ceiling and soffits of stairs for work 17.69 The
interior plastering up to floor two level and finished Specification thickness
even and smooth in (ii)Cement mortar 1:4 Booklet of plaster
(1cement :4 sand) mala plastring line , level and shall be
plumb to develop even surface as per instruction mm thick.
of engineer incharge etc complete.
25 Providing 20mm thick sand faced plaster on walls Building 107
upto height 10 meters above ground level work
consisting of 12mm thick backing coat of cm 1 :3 ( 1 Specification
cement : 3 sand )with other required Chemical Booklet
binding materia and 8mm thick finishing coat of cm
1 : 1 ( 1 cement : 1 sand) etc complete.
26 Providing throating or plaster drip and moulding to As per Approved
R.C.C. Chhajja. Separate Quality
27 Applying two coats of Birla or asian acrylic lippy As per Approved
(putty) and two coats of primer of approved brand Separate Quality
and manufacture on new wall surface to give an sheet
even shade including thoroughly brushing the Attached
surface free from mortar dropping and other
foreign matter and sand prepared smooth.
28 Wall Painting (three coats) with plastic emulation As per Approved
paint of approved brand and manufacture on Separate Quality
undecorated wall surface to give an even shade sheet
including thoroughly brushing the surface free from Attached
mortar droppings and other foreingnmatter and
sand papered smooth extra every subsequent coat
of wall painting with plastic emulation paint of
approved brand.
29 Ceilings painting (three coats) with plastic emulsion As per Approved
paint of approved brand and manufacture on Separate Quality
undecorated wall surface to give an even shade sheet
including throughly brushing the surface free from Attached
mortar droppings and other foreign matter and
sand papered smooth. painting with plastic
emulsion paint of approved brand on ceilings and
30 Finishing wall with weather proof exterior emulsion As per Approved
paint on wall surface (two coats) to give an Separate Quality
required shape even shade after thoroughly sheet
brushing the surface to remove all dirt, and Attached
remains of loose powdered materials.etc complete
31 Providing and laying polished Kota stone slab Building 86 14.43(A)
flooring over 20mm (Average) thick base of cement work
mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 Specification
(1-Lime putty :1.5 - coarse sand) laid over and Booklet
jointed with grey cement slurry mixed with pigment
to match the shade of slab including rubbing and
polishing etc. complete. (A)25mm thick
32 Providing and laying polished kota stone slab 25mm Building 87
thick in risers of steps,skirting Dedo and pillars laid work
on 10mm thick cement mortar 1:3 (1-Cement : 3 Specification
coarse sand) and jointed with gray cement slury Booklet
mixed with pigment to match the shade of slab
including rubbing and polishing etc. complete.
33 Providing and laying rough kota stone flooring As per Approved
over 20mm (Average) thick base of cement mortar Separate Quality
1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime sheet
putty :1.5 - coarse sand) laid over and jointed with Attached
grey cement slurry mixed with pigment to match
the shade of slab including rubbing and polishing
etc. complete. (A)25mm thick
34 P & L 24" x 24" vitrified 8 mm thick tile flooring As per Approved
over 20 mm (average) base of cement mortar 1:6 ( Separate Quality
1 cement: 6 coarse sand) on new surface or fixing sheet
on existing flooring by adhesive material including Attached
dismentaling of existing flooring and jointed with
color cement slurry including finised with flush
pointing & cleaning the surface etc. complete for
antiskid Matt finish as per approved sample
35 Providing and laying Vitrified tiles 8 to 10 mm thick As per Approved
, in skrting risers of steps and dedo on 10mm thick Separate Quality
cement plaster 1:3 (1-cement : 3-coarse sand) and sheet
jointed with white cement slurry Attached
36 Providing & laying Controlled cement concrete M As per Approved
250 grade in Trimix flooring /road for average 150 Separate Quality
mm thick wearing coat in RCC flooring without fly sheet
ash with lead of 10 Km from plant site including all Attached
other taxes octroi, transportation, pumping,
pouring, curing of concrete etc. complete including
cost of metallic C channel from work but excluding
the cost of reinforcement in R.C.C. M 250 Trimix
flooring work having average 150 mm thick wearing
coat in RCC flooring laid as detail design &
directed. The item of M 250 grade in Trimix flooring
including plant , machinery , tamping vibrating
finishing curing for 21 days , creating expansion
joint and filling in joints with bitumen or other
material as specified etc complete with all lead
and lift as directed by engineer in charge .
(Minimum cement level as per IS 456-2000 shall be
adopted for concrete grade) (C)Concrete Grade M-
37 Dewatering of TRI MIX M-250 floor concrete by As per Approved
means of vacuum dewatering using floater machine Separate Quality
and other necessary equipment , plant and labour sheet
etc complete as directed by engineer in chrge Attached
38 Providing & lying CERAMIC tiles 6 to 8 mm thick In As per Approved
skirting risers of steps and dado on 10mm. Th. Separate Quality
Cement plaster 1:3 (1 cement : 3 coarse sand ) sheet
pointing in white cement and jointed with white Attached
cement slurry. The tiles should be approved by
engineer in charge and architect , the color and
pattern and design as per instruction of architect
and as directed by engineer in charge etc complete
with first quality of tiles only fixing up to all and
any floor with all lead & lift etc complete
39 Providing and fixing of minimum 16 mm thick As per Approved
Green marble stone slab for jambs of doors and Separate Quality
window .Green marble stone should be spotless sheet
,without any crack , vain or other damages joined Attached
with grey cement slurry and matching pigment in
vertical and horizontal member , including rubbing
and polishing and full round edge moulding on
both the sides( edge), Mirror polishing curing of
the Green marble stone as per detail design and
instruction. The door frame should have
sanchwhich type Jambs stone fitting to
accommodate fixing of door where required , the
fixing of jambs with necessary binding wire tiles
piece,adhesive , clamp , fastener, white cement
and matching pigment other consumable, moulding
and polishing machinery other tools , tackles
required to complete the item. and where two
member vertical and horizontal meet it should cut
45 degree angle etc up to all floor with all lead &
lift etc complete. The Green marble stone size and
quality should be as per sample approved by
architect and Eng. in charge.
40 Providing and fixing of minimum 18 mm thick As per Approved
Marble stone slab of approved quality for flooring , Separate Quality
riser of steps, tread dedo , landing in stair case sheet
over Bed of 20mm ( average) thick base of cement Attached
mortar 1:6 (1cement : 6 coarse sand) or lime
mortar 1:1.5 laid and jointed with white cement
slurry and matching pigment including rubbing and
polishing complete for flooring in steps . The fixing
of Black Marble stone slab 18 mm thick at the stair
case steps up to all floor in raiser & tread including
edge moulding to flooring and two anti skid
grooves as per instruction of engineer in charge .
The fixing of Marble stone slab as per detail design
and instruction, including necessary Mirror
polishing , cutting of the stone , adhesive , clamp
fastener , other consumable and labour and fixing
up to all floor with all lead & lift etc complete as
directed by engineer in charge
41 Providing and fixing minimum 50mm wide sand As per Approved
blasting on Marble stone for stair case steps with Separate Quality
necessary tools tacjels , equipment plant as per sheet
detail design upto all floor with all lead & lift etc Attached
complete as per instruction of engineer in charge
42 Applying general insecticide pest control treatment As per Approved
to floors, cupboards etc including labour material Separate Quality
etc. complete. Using Heptachloride 20 EC. As Per sheet
6113_ pests Consentration Weight 0.50 percent is Attached
recommended one litre chemical emulsion dillute
with 39 liter of water will give. Total dillute
concrentration will be 40 litre inclusive of one litre
chemical emulsion appication 0.5 Litre chemical /
Sqm of surface is recommended as per I.S.
43 Providing and laying APP (Atactic Polypropylene As per Approved
Polymer) modified prefabricated five layer 3mm Separate Quality
thick water proofing membrane, black finished sheet
reinforced with non-woven polyester matt Attached
consisting of a coat of bitumen primer for bitumen
membrane @0.40 ltr/sqm. by the same membrane
manufacture of density at 25 C, 0.87-0.89 kg/ltr
and viscocity 70-160 cps. Over the primer coat the
layer membrane shall be laid using Butane torch
and sealing all joints etc., and preparing the surface
complete. The vital physical and chemical
parameters of the membrane shall be as under :
Joints strength in logitudinal and transverse
direction at 23 C as 650/450N/5cm. Tear strength
in longitudinal and transverse direction as
300/250N/. Softening point of membrence not less
than 150 C. Cold flexibility shall be upto -2 C when
tested in accordance with ASTM, M-5147. The
laying of membrane shall be got done through the
authorised applicator of the manufacturer of
membrane : (with 5 years service guarantee
44 Providing and laying cement concrete flooring 1:2:4 Building work 44 5.4.4.
(1-cement : 2-coarse sand : 4-graded stone Specification
aggregate 20mm nominal size) laid in one layer and Booklet
finished with a floating coat of neat cement. (B)
45 Providing and laying broken China Mosaic Flooring As per Approved
for terrace using 12 mm to 20 mm broken pieces of Separate Quality
glazed tiles to be laid over cement mortar 1:3 to sheet
plain or slope and to be tempered to bring mortar Attached
crème out up to surface using white cement
including rounding off junctions and extending
them up to 15cm along the wall, clearing with
water and oxalic acidic. as directed. .
46 Providing cement vata (10cm. x 10 cm. size) quarter Building work 124 17.0.0.1
round in cement mortar 1:1 including neat cement Specification
finishing, watering etc. complete. Booklet
47 Providing erecting and fixing double coated Syntex As per Approved
PVC. (ISI) water tank of required capacity each Separate Quality
with all necessary fittings and connection etc. sheet
complete on terrace. Attached
48 Providing and fixing to wall ceiling and floor 10.0 As per Approved
Kg. F/Cm2 working pressure poluthene pipes of the Separate Quality
following outside Dia. Low densidy, complete with sheet
special falnge compression type fittings, wall Attached
clipsetc. including making good the wall ceiling and
floor.(G)110 mm etc complete with propoer wall
clamping of Rain water pipe up to all floor level
with all lead and lift as per instruction of engineer
49 Providing and fixing stainless steel chicken mesh jali As per Approved
at specific location between R.C.C. and brick Separate Quality
masonry joints including fixing ,nailing while sheet
executing plastering on the various surface at any Attached
height including all labour & material to complete.
chicken mesh jali should be maximum 20 cm only.
the item as directed by engineer incharge etc.
50 Providing and fixing window having extruded As per Approved
aluminum Colour anodized section frame main Separate Quality
outer size 63.50 x38.10 x 1.95 mm,@ Wt 1.094 Kg / sheet
Rmt, horizontal two track member size 61.85 mm x Attached
31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt, vertical
member of size 61.85 mm x 31.75mm x 1.30 mm @
wt.of 0.659 Kg/mt with sliding shutters of
horizontal member size 40mm x 18mm x 1.29mm
@ wt.of 0.456Kg/mt, vertical member of size40mm
0.457 Kg/mt with 5 mm thick transparent bronze
colour tinted float glass with powder coated
aluminum fittings and fixtures and transparent
silicon sealant glass fixing to frame as per details
etc complete for window.
51 Providing and fixing alluminium Panelled As per Approved
single/double door Partly Glazed & Partly with 12 Separate Quality
mm thick both side pre laminated Particle Board sheet
with Frame having extruded alluminium color Attached
anodized section frame main Frame size
mm x 44.45 mm x 3.18mm ( of Section No.20011 @
wt. of 2.54 kg/mt )unit providing shutters of
bottom & Top rail- 114.30 mm x 25.40 mm x
3.18mm (of Section No.19511 @ wt. of 2.65 kg/mt )
Shutter Middle rail = 150 mm x 44.45 x 2.65 mm (of
Jindal Section No.20002 @ wt. of 2.79 kg/mt)
Vertical member Shutter style = 85.00 mm x 44 mm
x 3.00(of Jindal Section No.19509 @ wt. of
kg/mt).with 12mmth. both side pre laminated
particle board (novapan) conforming to IS:
Grade 1 Type II in panelling fixed in aluminium door
consisting of outer frame shutter as per design with
two pairs of standard handles, two pair of
concealed shoot bolts 250mm long and pin type
narrow style lock and thumb turn from the other
side, including all fixtures, fastening etc. complete
as directed and as per drawing and design. Rate
including hinges/Pivots and making provision for
fixing of fitting wherver required including the cost
of EPDM rubber/neoprene gasket required
Anodised aluminium (work for all floors)
52 Providing and fixing in position collapsible steel As per Approved
shutters with vertical channels 20 x 10 x 2 mm Separate Quality
braced with flat iron diagonals 20 x 5 mm size with sheet
top and bottom rails of T_rin 40x 40 x 6 mm with Attached
38mm dia, steel pulleys complete with bolts, nuts,
locking arrangements, stoppers handles including
applying a priming coat of red lead paint
53 Providing and fixing of decorative stainless steel SS As per Approved
304 Non magnetic best quality Railing as per Separate Quality
approved sample. The SS304 Railing shall be fix on sheet
the edge or periphery of staircase & steps as per Attached
detail design and instruction .The top horizontal SS
pipe should be of 50 mm Diameter with minimum
16/14 gauge pipe thickness and in between two
horizontal pipe 25 mm diameter with minimum
16/14 gauge pipe thickness , the vertical pillar pipe
shall be of 50mm diameter with minimum 14/12
gauge pipe wall thickness , including SS pipe
bending , SS 304 square sandwich and distance
peace for fitting & assembly at extension joint as
per detail design . The Providing and fixing of SS
railing including cutting, fabrication ,SS arc
welding, grinding , erection , fixing with necessary
machinery tools, tackles, labor and required civil
work as per detail design at specific location The SS
304 pipe railing should be fixed in the floor/ wall
by means of pipe socket , bush ,flange, bullet S.S
bolt, S.S L end key and other necessary hardware
and consumable required to complete in all aspect .
The item includes buffing, polishing , assembling of
the different unit of SS pipe Railing and required
civil work for the fixing of the SS 304 railing up to
all floor in perfect position etc complete as per
approved sample as directed by engineer in
54 Providing and fixing MS grill of required pattern to As per Approved
frames of window etc. with MS flats at required Separate Quality
spacing and frame around square or round bar with sheet
round headed bolts and nuts or by screw ( B ) Attached
Ornamental grill/Jali (Similar item) as detail design
with two coats of primer & enamel paints , the
shed and color as per instruction of engineer in
charge etc complete.
55 Providing and fixing 18 mm thick approved quality As per Approved
Marble stone mirror polished, machine cut counter Separate Quality
for Vanity counter , wash basin with support and sheet
stability which include zeri cutting refitting , Attached
plastering making good of surfaces , vanity
counters fascias patti of Marble stone with
molding, cut out for wash basin sink required sizes
of approved shade, texture and color laid in zeri in
line level and plumb with cutting out v section
claning out wetting grouting with cement slurry 1:
3( 1 cement : 3 Coarse sand ) with joints treated
with white cement mixed with matching pigment
epoxy touch ups incl. rubbing, Mirror polishing
curing etc. complete at all levels as per instruction
of Architect or engineer in charge.
56 Providing and fixing pre-cast Rubber Dye / steel As per Approved
Dye inter locking concrete block 60mm thick with Separate Quality
grade of concrete M300 pnumatic compressed / sheet
vibrated mechanically and as per approved design Attached
Confirming to IS 15658 : 2006 including 35 mm
Sand layer for levelling and filling the joint with
sand in proper line and level as per guidlines of IRC
: SP 63-2018 etc. Complete
57 Providing and fixing pre-cast concrete kerb stone of As per Approved
gray cement based concrete block 30cm Separate Quality
length,30cm height and 15cm thick of M250 grade sheet
concret as per approved design and including Attached
excavation for fixing in proper line and level,filling
the joint with C:M 1:3 (1cement:3fine sand) etc
58 Providing and fixing of CIRCULAR counter type As per Approved
wash basin having size of 470 x 470 x 200 mm Separate Quality
counter type with CI / MS/SS clamps or fastener as sheet
per approved sample .The counter type wash Attached
basinin should be of ivory colour . The Item shall be
including painting of fittings and brackets, cutting
and making good the walls and floors wherever
required including mior civil and painting works &
fitting up to all fllor with all lead & lift as per detial
specification , approved sample and as per
instruction of Architect & engineer in charge
59 Providing and fixing of pillar tap 1/2" with capstan As per Approved
head. screw down high pressure with screws, Separate Quality
shanks and back nuts.(A) 15 mm dia. as approved sheet
by engg. in charge with necessary hex nipple fitting, Attached
Teflon tap and other consumable and labor etc
complete up to ALL floor level with all lead and lift
including mior civil and painting works & fitting up
to all fllor with all lead & lift as per detial
specification , approved sample and as per
instruction of Architect & engineer in charge
60 providing and fixing of Angular stop cock with wall As per Approved
flange with necessary hex nipple fitting, Teflon tap Separate Quality
and other consumable and labor etc complete 15 sheet
mm dia approved by engineer in charge with Attached
necessary coupling of approved quality for wash
basin. including fixing in pipe line etc complete up
to sixth floor level with all lead and lift including
mior civil and painting works & fitting up to all fllor
with all lead & lift as per detial specification
approved sample and as per instruction of Architect
& engineer in charge
61 Providing and fixing chromium plated, bottle trap Building work 171 23.00.4.
with necessary couplings of approved quality for Specification
wash basin. Booklet
62 Providing and fixing wire braded PVC Connection As per Approved
flexible pipe of approved brand with brass union Separate Quality
on both ends with ferule type connector 45 cm long sheet
and 15 mm nominal bore un plasticized wire Attached
braded PVC Connection pipe for angle cock (in let)
of following size. (A) 15 mm dia etc complete up
to all floor level with all lead and lift including mior
civil and painting works & fitting up to all fllor with
all lead & lift as per detial specification , approved
sample and as per instruction of Architect &
engineer in charge
63 Providing and fixing C.P. brass waste for washbasin Building work
or sink. (A) 32mmdia. Specification 168 23.135 (A)
64 Providing and fixing of C.P. brass Towel Ring As per Approved
Square with rubit clean with screws, hardware as Separate Quality
approved by client .The item includes fixing on sheet
wall/tiles with necessary screw , fitting, Teflon tap Attached
, other consumable and labour with minor civil
work etc complete up to sixth floor level with all
lead and lift etc. complete, including mior civil and
painting works & fitting up to all fllor with all lead &
lift as per detial specification , approved sample
and as per instruction of Architect & engineer in
65 Providing and fixing PVC SWR Nahni trap IS 14735 As per Approved
for drain - 100 mm diameter with jali of the Separate Quality
following nominal diameter of self cleansing design sheet
with C.I scread down or hinged grating including Attached
the cost of cutting and making good the walls.
66 Providing and fixing S.W.gully trap with C.I.grating Building 176 24.19(1)
brick masonry chamber and water tight c.i. cover work
with frame of 300 mm x 300 mm size (inside )with Specification
standard weight. (I) square month traps.150 mm x Booklet
100 mm size p or r type
67 constructing brick masonry chamber for under Building 183 24.44(1)
ground c.I. Inspection chamber and band with work
bricks having crushing strenght not less than 35 Specification
kg/cm2 in cm 1:5. c.i. cover with frame (light duty) Booklet
455 mm x 610 mm internal dimension, total weight
of cover with fram to be not lass then
kg.weight of cover 23kg and wt. of frame 15 kg )
r.c.c top slab with 1:2:4 mix (1 cement:2 sand:4
aggregates 20 mm size) foundation concrete 1:5:10
,in side plaster 15 mm thick with cement mortar 1:3
finished smooth with a floating coat of neat cement
on walls and bed concrete etc. complete.) (1) inside
dimension 455 mm x 610 mm and 450 mm deep for
68 constructing. manhole with r.c.c slab in 1:2:4 mix Building 178 2.4.27
(1 cement:2 sand:4 aggregates 20 mm size) work
foundation concrete 1:3:6( 1 cement:3 sand :6 brick Specification
bats 40+50 mm size ,in side plaster 15 mm thick Booklet
with cement mortar 1:5 (1 cement: 5 coarse sand)
finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 (1
cement:2 coarse sand :4 stone aggregate 20 mm)
finished smooth complete including curing and
testing. (i) inside size 900 mm x 1200mm and 1:5
mm deep including C.I.cover with frame size
560mm total weight of cover and frame to be not
less than 128 kgs. (wt of frame 64 kgs) (A) with
230cm thick walls of brick masonary using brick
having crushing strength not less than 35 kgs/sq
cm. in cement mortar 1:5 (1 cement :5 coarse sand)
(1) A type depth 0.90 meter 150 mm diameter
69 constructing. manhole with r.c.c slab in 1:2:4 mix Building 178 2.4.27
(1 cement:2 sand:4 aggregates 20 mm size) work
foundation concrete 1:3:6( 1 cement:3 sand :6 brick Specification
bats 40+50 mm size ,in side plaster 15 mm thick Booklet
with cement mortar 1:5 (1 cement: 5 coarse sand)
finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 (1
cement:2 coarse sand :4 stone aggregate 20 mm)
finished smooth complete including curing and
testing. (i) inside size 900 mm x 1200mm and 1:5
mm deep including C.I.cover with frame size
560mm total weight of cover and frame to be not
less than 128 kgs. (wt of frame 64 kgs) (A) with
230cm thick walls of brick masonary using brick
having crushing strength not less than 35 kgs/sq
cm. in cement mortar 1:5 (1 cement :5 coarse sand)
(1)B type depth 1.50 meter 150 mm diameter
70 Providing and fixing conceled center point to wall As per Approved
celling and floor CPVC PIPE (SDR -13.5) pipe having Separate Quality
NSFseal for portable water of following dia nominal sheet
bore ,tube ,fittings, and clamp including making Attached
good the wall, ceiling and floor. (A) 15 mm dia.
71 Providing and fixing conceled center point to wall As per Approved
celling and floor CPVC PIPE (SDR -13.5) pipe having Separate Quality
NSFseal for portable water of following dia nominal sheet
bore ,tube ,fittings, and clamp including making Attached
good the wall, ceiling and floor. (c) 25 mm dia.
72 Providing and fixing conceled center point to wall As per Approved
celling and floor CPVC PIPE (SDR -13.5) pipe having Separate Quality
NSFseal for portable water of following dia nominal sheet
bore ,tube ,fittings, and clamp including making Attached
good the wall, ceiling and floor (E) 40 mm dia.
73 Providing and fixing conceled center point to wall As per Approved
celling and floor CPVC PIPE (SDR -13.5) pipe having Separate Quality
NSFseal for portable water of following dia nominal sheet
bore ,tube ,fittings, and clamp including making Attached
good the wall, ceiling and floor (f) 50 mm dia.
74 providing & fixing to wall ceiling and floor 10 Building 162
kg/f/cum working pressure polyethylene pipes of work
the following outside diameter ,low density Specification
complete with special flange compression type Booklet
fittings ,wall clamped making good wall ,cling and
floor - 75 mm dia
75 providing & fixing to wall ceiling and floor 10 Building 162
kg/f/cum working pressure polyethylene pipes of work
the following outside diameter ,low density Specification
complete with special flange compression type Booklet
fittings ,wall clamped making good wall ,cling and
floor - 110 mm dia
76 Providing and fixing ball cock of approved. quality Building 173 23.00.5.(B)
as directed.(A) Copper Metal (ii) 50mm dia. work
77 Providing and fixing ball cock of approved. quality Building 172 23.00.5.(A)
as directed.(A) Copper Metal (ii)25 mm dia. work
78 providing and fixing gun metal check or non return Building 171
full way wheel valve ( E ) 40 mm mm diameter of work
approved quality , fixing as directed up to all lead Specification
and lift as directed by engineer in chrage Booklet
79 Making connection of galvanized Mild steel As per Approved
distribution branch with galvanized mild steel main Separate Quality
50mm to 80mm nominal bore by providing and sheet
fixing tee including cutting and threading the pipes Attached
Electrical works
80 Point wiring for Light / Bell with 2-1.5 sq.mm & Electrical Approved
earthwire of 1.5 sq.mm (Green) both are of ISI work Quality
marked 1.1 KV grade FRLS PVC insulated Specification
multistrand copper wires, in following type of pipe Booklet
to be erected concealed in/ on surface on
wall/ceiling complete with 6A Modular type switch
/ bell push & accessories and earth continuity of
following type, erected on PVC / Metallic box,
single mounting base frame covered with
textured/metallic front plate modules erected on /
in wall / ceiling as per pipe erected, with necessary
Lamp holder / ceiling rose / H.D.Connector as
directed.(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete CAT III
81 Point wiring for FAN with 2-1.5 sq.mm & earthwire Electrical Approved
of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV work Quality
Grade FRLS PVC insulated multistrand copper Specification
wires, in following type of pipe to be erected Booklet
concealed in / flushed on wall/ceiling complete
with 6A Modular type switch and hum free EME
four or more step type electronic fan regulator with
separately mounted and accessories with earth
continuity of following type erected on PVC /
Metallic box, single mounting base frame covered
with textured/metallic front plate modules erected
on / in wall / ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as
directed.(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
completecat III
82 Providing following type of Modular Type Electrical Approved
Accessories mounted with PVC / metallic/Wooden work Quality
box, single mounting base frame covered with Specification
textured / metallic/white front plate , modules Booklet
erected with necessary connections as per site
situation directed by Engineer In charge.(1)One No.
SP 6 Amp. Cat. III
83 Providing following type of Modular Type Electrical Approved
Accessories mounted with PVC / metallic/Wooden work Quality
box, single mounting base frame covered with Specification
textured / metallic/white front plate , modules Booklet
erected with necessary connections as per site
situation directed by Engineer In charge.(2) One No
5 pin plug. Cat. III
84 Point wiring for Individual Plug with & earthwire of Electrical Approved
1.5 sq.mm (Green) both are of ISI marked 1.1 KV work Quality
grade FRLS PVC insulated multistrand copper wires, Specification
in following type of to be erected concealed in / on Booklet
surface of wall / ceiling complete with Modular
type switch & 5 pin Plug erected on PVC / Metallic
box covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe erected
with following type of accessories. [II] For 16A Plug
and 16 amp switch with 2-2.5 sq.mm Cu. Wire
from mcb db board. (f) with medium class Rigid
PVC pipe and accessories erected concealed in
wall/ceiling complete Cat. III
85 Point wiring for Individual Plug with & earthwire of Electrical Approved
1.5 sq.mm (Green) both are of ISI marked 1.1 KV work Quality
grade FRLS PVC insulated multistrand copper wires, Specification
in following type of to be erected concealed in / on Booklet
surface of wall / ceiling complete with Modular
type switch & 5 pin Plug erected on PVC / Metallic
box covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe erected
with following type of accessories.[III] For 16A Plug
and 16 amp switch with 2-4 sq.mm Cu. Wire with
2.5 sq.mm ( green) earthing wire from mcb d b
board. (f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
complete Cat. III
86 Point wiring for on board Looped Plug with 6A Electrical Approved
Modular type switch & 5 pin socket erected on PVC work Quality
/ Metallic / Wooden box, single mounting base Specification
frame covered with textured / metallic /white Booklet
front plate modules erected on / in wall / ceiling
with following type accessories cat III
87 Providing following type of Modular Type Electrical Approved
Accessories mounted with pvc / metallic box, single work Quality
mounting base frame covered with textured / Specification
metallic front plate , modules erected with Booklet
necessary connection. As desired by Engineer In
charge. (7) Blank Plate Single
88 Providing following type of Modular Type Electrical Approved
Accessories mounted with pvc / metallic box, single work Quality
mounting base frame covered with textured / Specification
metallic front plate , modules erected with Booklet
necessary connection. As desired by Engineer In
charge. (8) Computer RJ-45 socket
89 Supplying & erecting Delton or approved make Electrical Approved
Telephone Cable electrolytic copper conductor PE work Quality
insulation twisted in two pairs, & wrapped with Specification
FRLS PVC tape & sheathed with FRLS PVC or HFFR Booklet
outer Jacket suitable for telephone wiring &
confirming to C-DOT erected in existing pipe. of
following size of conductors & nos.of pairs. With
necessary connections. [A] Conductor Size 0.5 mm
(b) Armoured [Jelly Filled] (2) 2 PAIR
90 Providing and erecting ISI mark Medium class RIGID Electrical Approved
PVC PIPES of following size complete to be erected work Quality
on/in wall or ceiling erected with necessary PVC Specification
fittings & Junction boxes fixed with adhesive Booklet
solution & Clamps with following diameter of pipes,
in approved manner as directed (a) 20 mm
91 Providing & erecting PVC Corrugated Flexible Electrical Approved
Conduit with required nos. of coupling, PVC bushes, work Quality
Check-nuts etc. complete of following sizes.(2) 25 Specification
92 Providing and erecting Mains with 1.1 KV grade Electrical Approved
FRLS PVC insulated ISI marked stranded Copper work Quality
conductor wire in following type of pipe to be Specification
erected concealed in /flushed on wall/ceiling, with Booklet
1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity
of following size (a) with medium class Rigid PVC
pipe and accessories(a) 2 wire 1.5 sq. mm
93 Providing and erecting Mains with 1.1 KV grade Electrical Approved
FRLS PVC insulated ISI marked stranded Copper work Quality
conductor wire in following type of pipe to be Specification
erected concealed in /flushed on wall/ceiling, with Booklet
1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity
of following size (a) with medium class Rigid PVC
pipe and accessories (b) 2 wire 2.5 sq. mm
94 providing and erecting Mains with 1.1 KV grade Electrical Approved
FRLS PVC insulated ISI marked stranded Copper work Quality
conductor wire in following type of pipe to be Specification
erected in / on wall / ceiling with 2.5 sq. mm Booklet
copper conductor FRLS PVC insulated stranded wire
of green colour for earth continuity of following
size (a) with medium class Rigid PVC pipe and
accessories.(a) 2 wire 4 sq. mm
95 providing and erecting Mains with 1.1 KV grade Electrical Approved
FRLS PVC insulated ISI marked stranded Copper work Quality
conductor wire in following type of pipe to be Specification
erected in / on wall / ceiling with 2.5 sq. mm Booklet
copper conductor FRLS PVC insulated stranded wire
of green colour for earth continuity of following
size (a) with medium class Rigid PVC pipe and
accessories g) 4 wire 4 sq. mm.
96 providing and erecting Mains with 1.1 KV grade Electrical Approved
FRLS PVC insulated ISI marked stranded Copper work Quality
conductor wire in following type of pipe to be Specification
erected in / on wall / ceiling with 2.5 sq. mm Booklet
copper conductor FRLS PVC insulated stranded wire
of green colour for earth continuity of following
size (a) with medium class Rigid PVC pipe and
accessories(b) 2 wire 6 sq. mm
97 providing and erecting Mains with 1.1 KV grade Electrical Approved
FRLS PVC insulated ISI marked stranded Copper work Quality
conductor wire in following type of pipe to be Specification
erected in / on wall / ceiling with 2.5 sq. mm Booklet
copper conductor FRLS PVC insulated stranded wire
of green colour for earth continuity of following
size (a) with medium class Rigid PVC pipe and
accessories(i) 4 wire 10 sq. mm (use earth wire of
98 Providing & Erecting approved make following size Electrical Approved
of TV Co-axial flexible cable comprising inner work Quality
conductor of solid bare copper insulated with Foam Specification
PE & Secondary conductor made of poly - Booklet
Aluminium film bonded Al. Braids @ suitable
coverage overall sheathed with black PVC
insulation. b).RG-6
99 Supplying & erecting approved make LAN cable of Electrical Approved
following size in existing pipe as per direction[C] work Quality
CAT - 6 Specification
100 Providing & erecting Switch board for Computer Electrical Approved
or electric apparatus consisting of following work Quality
modular type accessories mounted with PVC / Specification
Metallic concealed /open box with single mounting Booklet
base frame covered with textured/metallic /white
front late, modules erected with necessary
connections as directed 1 no. 6A /16A universal
plug-switch combined.3 nos. 6A Switch 3 nos. 6A
pin Plug For Modular Type Accessories CAT III
101 Supplying & erecting Approved make call bell Electrical Approved
indicator with buzzing sound and Red light work Quality
indicating lamp with Red light button to attend the Specification
call suitable for 240 v 50 c/s supply to be erected. Booklet
102 Supplying and erecting LED indoor fittings with Electrical Approved
LEDs of wattage 0.2 Watt to 0.5 Watt assembled on work Quality
single MCPCB, with housing used as a heat sink Specification
shall be made of thick sheet Steel conforming to IS: Booklet
513/CRCA/ aluminium die cast powder coated and
high U.V. & corrosion resistance with diffuser with
company mark/name 120 to 300 V,Power Factor
more than 0.9, THD < 10 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens /watt ,LED
efficiency-110 lumens /wattLED driver efficiency >
85 % CREE / OSRAM / PHILIPS Lumileds / NICHIA /
SEOUL /Bridgelux make LED used for luminaire. (
fitting required LM-79 & LM-80 Certificates )(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges
shown.) (A) Tube Light with integral driver (a) 5-9
Watts, Surge-2 KV, IP-20,2 feet CAT III
103 Supplying and erecting LED indoor fittings with Electrical Approved
LEDs of wattage 0.2 Watt to 0.5 Watt assembled on work Quality
single MCPCB, with housing used as a heat sink Specification
shall be made of thick sheet Steel conforming to IS: Booklet
513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with
company mark/name 160V to 270V,Power Factor
more than 0.95, THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver
efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.) (A) Square/ Circular
shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips
complete.IP20 (iii) 16-20 watts, Surge-2 KV CAT III
104 Supplying and erecting LED street light / Flood light Electrical Approved
fittings with High power White LEDs wattage of work Quality
1Watt and above assembled on single MCPCB, Specification
efficiency more than 130 lm/w and corrosion free Booklet
High pressure die cast aluminum housing with
smooth finish powder coated and heat sink
extruded aluminium with diffuser and
Polycarbonate optics/ lenses with company
mark/name engraved or embossed 120 to
V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver efficiency >
85 %.CREE /RAM / PHILIPS Lumileds / NICHIA /
SEOUL/ dgeLux (U.S.A.) make LED used for
luminaire. ( fittings required LM-79 & LM-80
certificates) (NOTE: Below escription have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.) (B) Flood Light (IP-65),
Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection.
(iv) above 90 to 120 watts CAT III
105 Providing and erecting required size Copper strip Electrical Approved
for earthing of H.T. OCB / ACB/ Transformer, LT work Quality
panel board, Motors etc. using copper clamp. Specification
106 Supplying & erecting earth pit of minimum bore Electrical Approved
dia.150mm size approved make Earthing Electrode work Quality
consisting Pipe-in-Pipe Technology as per IS 3043- Specification
1987 made of corrosion free hot dipped G.I.Pipes Booklet
having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having
200-250 Micron galvanising, connection terminal
dia of 12mm with constant ohmic value surrounded
by highly conductive compound with high charge
dissipation suitable for following type of
applications with chamber and heavy duty
cover.(approved make OEM has to submit test
certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:-
W/ meter testing as per IEC 62561-2017, Voltage
drop:- < 1 volt at no load & dry form, Sulphar
content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for
long time Necessary test report must be
submitted. (b)For Electrical installation up to 11 KV
in normal soil. Length of Pipe : 2.00 mtrs Back filling
Compound :1 no. Bag of 25 Kg.
107 Providing and erecting XLPE(IS:7098)(I)-88 ISI Electrical Approved
armoured cable multistrand Aluminium conductor work Quality
for 1.1 KV. to be laid on wall with necessary Specification
clamps or in existing trench / pipe of following size Booklet
of cables (E) 3 1/2 core 120 Sq. mm ( 70 Sq. mm
108 Making trench in soft soil of suitable width of 90 Electrical Approved
cms deep for laying cable or locating the fault all work Quality
over the run and back filling the same and making Specification
the surface as a normal ground. Booklet
109 Covering of cable with second class bricks or Electrical Approved
cement tiles laid cover the cable crosswise & also work Quality
on both sides with covering of 7. 5 Cms. layer of Specification
sand above & below cable (16 bricks per meter) Booklet
110 Providing and fixing heavy duty flange type brass Electrical Approved
cable gland with rubber ring for PVC insulated work Quality
armourd cable complete with out going tails, Specification
insulating tape etc. for following size of cables. d) 2 Booklet
to 4 Core 10 Sq.mm
111 Providing and fixing heavy duty flange type brass Electrical Approved
cable gland with rubber ring for PVC insulated work Quality
armourd cable complete with out going tails, Specification
insulating tape etc. for following size of cables. (E) 3 Booklet
& 1/2 core 120 Sq. mm
112 Solderiess crimping type Aluminum lugs Electrical Approved
conforming to IS suitable for cable of following size work Quality
evenly crimped with high pressure tool & Specification
connected to switchgear terminals with brass / Booklet
cadmium plated nut bolts in as approved manner
113 Solderiess crimping type Aluminum lugs Electrical Approved
conforming to IS suitable for cable of following size work Quality
evenly crimped with high pressure tool & Specification
connected to switchgear terminals with brass / Booklet
cadmium plated nut bolts in as approved manner
114 Providing & erecting weather proof, dust & vermin Electrical Approved
proof, floor mounted front operated indoor type work Quality
cubical panel board necessary IP-42 and above Specification
protection as per approval from engineer incharge Booklet
made from 14 SWG thick CRC M.S. sheet for outer
body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories
supporting angles/ flats channel including cutting,
bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of
supplied switch gears, BUSBARS, suitable size of
inter connecting PVC copper wire / copper-
aluminium strips, rubber grommets, rib, bakelite
control fuses/MCB for measuring instruments,
earth bus & earth bolts, foundation flange - bolts-
base Plates, sufficient nos. of hinged doors, handles
with locking arrangement and rubber gasket,heavy
duty end terminal connection,danger notice
board,necessary ventilation,earthing strip
complete. The Panel shall be painted with epoxy
powder coating.
(The rates excludes the cost of switchgears, bus
bars, inter connecting mains, meters Fuses etc. The
dimension shall be measured excluding base
beams). The panel shall be supplied with following
approved manufacturers with following size.(A) The
standard companies switch gear shall be used and
only manufacturers at CPRI approved factory and
shall be certified by that company whose switch
gears are used after fabrication for beneficial use.
(I) with 350mm depth
115 Operational Handle Assembly Complete for up to Electrical Approved
800A.(Rotry Handal) work Quality
116 Supplying and erecting triple pole & neutral 440V/ Electrical Approved
500V panel mounting Aluminium Busbars with four work Quality
equal Nos. of bus having current density not more Specification
than 0.8 Amp. / sq.mm (Rated current / cross Booklet
section area) duly wrapped with colour insulating
tape for phase sequence of following current
carrying capacity, erected with necessary bus bar
supports /insulators, main cable socket to each
busbar,erected in existing cubical panel with
necessary connections. (E) Suitable for 400 Amp.
117 Approved make Four pole moulded case circuit Electrical Approved
breaker having breaking capacity ICU of 25 KA. at work Quality
415 V,having normal current rating up to 25 A to Specification
100A. with Fixed thermal & magnetic release Booklet
suitable to work on A.C. supply 50 c/s. with all
internal connections & complete erected in existing
16 G.M.S. housing. ICS=100% ICU only CAT III
118 Providing & erecting Approved make Power Saving Electrical Approved
50 Watt Ceiling Fan with double ball bearing ISI work Quality
mark with Condenser 230 volt A.C. 50 Hz 1200 mm Specification
sweep complete having 3blades with aluminium Booklet
blades with , canopy & 30 cm. down rod erected
with earthing.(Make shall be approved by Engineer
119 Supplying and erecting 19 / 20 mm. nominal bore Electrical Approved
Medium Class M.S. Pipe down rod erected duly work Quality
painted for fan complete with necessary 24/ O.20, Specification
3 core flexible wire with earthing. Booklet
120 Supplying & erecting Fan Hook of 10 mm M.S. Electrical Approved
Round bar grouted in RCC slab with Making the site work Quality
as original. Specification
121 Supplying & erecting fan hook box of 10 mm M.S. Electrical Approved
round bar bounded to the RCC bars up to 50mm work Quality
length each side and pierced through a 16 Gauge Specification
M.S. box / Heavy Duty PVC box complete erected Booklet
concealed in Ceiling with necessary finishing.
122 Providing 2.5mm.thick laminated acrylic sheet to Electrical Approved
cover the fan hook or Fan box. work Quality
123 Supplying & erecting single phase approved make Electrical Approved
industrial exhaust fan suitable for medium duty ring work Quality
mounted low noise operation suitable for medium Specification
duty having following dia size and maximum speed Booklet
in RPM[B] 380 mm dia 900 RPM
124 Providing suitable M.S. louver shutter of the Electrical Approved
Exhaust fan. work Quality
125 Providing recess in wall or window frame suitable Electrical Approved
for erection of Exhaust fan complete with work Quality
plastering and colour washing to match the colour Specification
of the wall or window complete with expanded Booklet
metal in order to render the fitting in accessible
and the room water-proof.
126 providing and erecting Mains with ISI marked, Electrical Approved
1.5KV grade electrolyte multi stranded, annealed work Quality
copper conductor with heat resistant PVC insulated Specification
conforms to IS 694, IEC - 227 erected in existing Booklet
pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and
bolts if required. .(e) One wire 6.00 sq. mm
127 providing and erecting Mains with ISI marked, Electrical Approved
1.5KV grade electrolyte multi stranded, annealed work Quality
copper conductor with heat resistant PVC insulated Specification
conforms to IS 694, IEC - 227 erected in existing Booklet
pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and
bolts if required.. f) One wire 10.00 sq. mm
128 providing and erecting Mains with ISI marked, Electrical Approved
1.5KV grade electrolyte multi stranded, annealed work Quality
copper conductor with heat resistant PVC insulated Specification
conforms to IS 694, IEC - 227 erected in existing Booklet
pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and
bolts if required. g) One wire 16.00 sq. mm
129 providing and erecting Mains with ISI marked, Electrical Approved
1.5KV grade electrolyte multi stranded, annealed work Quality
copper conductor with heat resistant PVC insulated Specification
conforms to IS 694, IEC - 227 erected in existing Booklet
pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and
bolts if required.. h) One wire 25.00 sq. mm
130 Supplying and erecting approved make Digital multi Electrical Approved
Fuction paramater for measures and display, V, A, work Quality
Hz, Kw, PF, kva, kwh, Run HRS with Rs-485 with all Specification
connection wiring etc. with manufactures Booklet
calibration certificate.
131 Supplying & erecting push button type telephone Electrical Approved
instrument having speaker phone Caller ID & hands work Quality
free dialing system & 30 memories with display Specification
system (a) Single line BEETEL/panasonic or Booklet
equivalent make
132 Providing printed instruction chart both in English Electrical Approved
and Gujarati and duly framed with front glasses, for work Quality
treatment of person suffering from Electric shock Specification
133 Providing and erecting Sheet Steel powder coated Electrical Approved
MCB distribution board - flush / surface mounted work Quality
fitted with busbar, neutral link, earth bar and DIN Specification
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 Booklet
without MCB to house appropriate nos. of
MCBs.(The DBs should be used of same company of
MCB to be used) suitable for(B) three phase
incoming and single phase horizontal type outgoing
Per phase isolation type (PPI) (b) sheet steel double
door (iii)8 way
134 Approved make ELCBs / RCCBs conforming to Electrical Approved
IS:12640 and having sensitivity of 30 m A and Short work Quality
Circuit with stand capacity of 6KA and suitable for Specification
operation on single phase 240 V having Booklet
characteristic of quick action & tripping with all
advance feature & do not incorporate any
electronic component for following Max. rating. (ii)
40Amps. DP Cat III
135 providing and erecting Miniature circuit breaker Electrical Approved
single pole 6A to 25A suitable to operate on 240 V work Quality
A.C. system and having breaking capacity 10 KA to Specification
be erected in existing box. confirming to IS Booklet
8828/1996 with ISI Mark Cat-III
136 Providing & erecting 415 V MCB Four Pole for Electrical Approved
Motor & Inductive Load (C Curve) having 10KA work Quality
breaking capacity & confirms to IS :8828 in existing Specification
box having following capacity (B) 63 Amp. Cat-III Booklet
137 Providing and erecting approved make split air- Electrical Approved
conditioning unit consisting of copper condensing work Quality
unit with fan motor, hermetically sealed rotary Specification
compressor with accessories etc. duly connected Booklet
separately erected evaporating unit and blower
motor with its accessories by means of extra
supplied proper insulated copper tubing,drain PVC
pipes suitable for ( cost includes powder coated
Stand, Eco Friendly green gas charging, 15A plug
top & Remote Control) with necessary core cutting.
For 3 Star Rating of current year (b) for 1.5 ton
138 Supplying and erecting insulated pair of soft copper Electrical Approved
tubing including power and control cable,necessary work Quality
PVC drain pipes for Split AC machine up to 4 TR Specification
capacity Booklet
Note : For all the above items units for payment is applicable as per schedule - B only .The separate sheet
attached which is for application of general workmanship and material specification, the detail specification
and mode of measurement for all the item will as per instruction of engineer in charge and shall be final and
binding to all contractors
Detail Specification of Construction of VCC department for Veterinary science collage at
kamdhenu university Navsari
Providing and laying rubble for appron (eachstone weighting not less than 40Kg.) including and packing and filing in
the interestices with quarry-spalls.
Stones used for rubble packing under floors on grade, foundations etc., shall be clean, hard, durable rock free from
veins, flaws, laminations, weathering and other defects. Stones shall generally conform to the requirements
stipulated in IS: 1597 (Part I) Stones shall be as regular as can be obtained from quarries. Stones shall be of height
equal to the thickness of the packing proposed with a tolerance of 10 mm. Stones shall not have a base area± less
than 250 sq cm nor more than 500 sq.cm, and the smallest dimension of any stone shall not be less than half the
largest dimension. The quality and size of stones shall be subject to the approval of the client .
Stones shall be hand packed carefully and laid with their largest base downwards resting flat on the prepared sub-
grade and with their height equal to the thickness of the packing. Stones shall be laid breaking joints and in close
contact with each other. All interstices between the stones shall be wedged-in by small stones of suitable size, well
driven in by crow bars and hammers to ensure tight packing and complete filling-in of the interstices. The wedging
shall be carried out simultaneously with the placing in position of rubble packing and shall not lag behind. After
this, any interstices between the smaller wedged stones shall be unfilled with clean hard sand by brooming so as to
fill the joints completely. The laid rubble packing shall be sprinkled with water and compacted by using suitable
rammers. Base Concrete: The thickness and grade of concrete and reinforcement shall be as specified in items of
works prepared by the contractor. Before placing the blinding concrete, the sub-base of rubble packing shall be
properly wetted and rammed. Concrete for the base shall then be deposited between the forms, thoroughly
tamped and the surface finished level with the top edges of the forms. Two or three hours after the concrete has
been laid in position, the surface shall be roughened using steel wire brush to remove any scum or laitance and
swept clean so that the coarse aggregates are exposed. The surface of the base concrete shall be left rough to
provide adequate bond for the floor finish to be provided later.
Mode of Measurements & Payment
The payment shall be made for filling in plinth and trenches. No deduction shall be made for shrinkage or voids, if
consolidated as instructed above. The rate shall be for a unit of one cubic meter.
Masonry work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for
super structure above plinth level up to floor two level in cement mortar 1:5 ( 1 cement : 5 fine sand ) complete as
per Technical Specification
Autoclaved Aerated Concrete shall be Lightweight, Load-bearing, High-insulating, Durable as per specify sizes and
strengths. AAC Blocks as per IS 6041 (1985): Code of practice for construction of autoclaved cellular concrete block
masonry [CED 53: Cement Matrix Products], sand , cement water necessary scaffolding , plant machinery , tools
tackles etc complete the item Technical Specification of AAC
Property Units AAC Block
Size mm 600 x 200 x (75 to 300),
Size Tolerance mm ±
Compressive Strength N/mm 2 3 – 4.5 (IS 2185 part 3)
Normal Dry Density Kg / m 3 550 –
Property Units AAC Block
Sound Reduction Index Db 45 for 200 mm Thick Wall
Fire Resistance Hrs. 2 to 6 (Depending on Thickness)
Thermal Conductivity “K” W / m-k 0.16 –
Drying Shrinkage % 0.04% (Size of block)
AAC is produced out of a mix of quartz sand and/or pulverized fly ash (PFA), lime, cement, gypsum, water and
aluminum and is hardened by steam-curing in autoclaves. As a result of its excellent properties,. AAC contains 60% to
85% air by volume. It is then autoclaved under heat and pressure to create its unique properties. AAC has excellent
thermal insulation and acoustic absorption properties. AAC is fire and pest resistant, and is economically and
environmentally superior to the more traditional structural building materials such as concrete, wood, brick and
At the point when AAC is blended and cast in structures, a few compound responses occur that give AAC its light
weight (20% of the heaviness of cement) and warm properties. Aluminum powder responds with calcium hydroxide
and water to frame hydrogen. The hydrogen gas froths and copies the volume of the crude blend making gas rises to
3mm (⅛ inch) in distance across. Toward the end of the frothing procedure, the hydrogen escapes into the air and is
supplanted via air.AAC Blocks is a unique and excellent type of building material due to its super heat, fire and sound
resistance, AAC blocks are lightweight and offers ultimate workability, flexibility and durability. Its main ingredients
include sand, water, quicklime, cement and gypsum. The chemical reaction due to the aluminum paste provides AAC
its distinct porous structure, lightness, and insulation properties, completely different compared to other lightweight
concrete materials. When the forms are removed from the material, it is solid but still soft. It is then cut into either
blocks or panels, and placed in an autoclave chamber for 12 hours. During this steam pressure hardening process,
when the temperature reaches 190° Celsius (374° Fahrenheit) and the pressure reaches 8 to 12 bars, quartz sand
reacts with calcium hydroxide to form calcium silicate hydrate, which gives AAC its high strength and other unique
properties. Because of the relatively low temperature used AAC blocks are not considered fired brick but a
lightweight concrete masonry unit. After the autoclaving process, the material is ready for immediate use on the
construction site. Depending on its density, up to 80% of the volume of an AAC block is air. AAC's low density also
accounts for its low structural compression strength. It can carry loads of up to 8 MPa (1,160 PSI), approximately 50%
of the compressive strength of regular concrete. AAC offers incredible opportunities to increase building quality and
at the same time reduce costs at the construction site.
3.0. Mode of measurements & payment
3.1. The Perforated brick masonry work up to all floor 20 meter height from ground level shall be measured
and paid under this item rate includes cost of all materials & labor.
3.2. Perforated work in parapet shall be included in the corresponding masonry item of floor immediately
below the floor above which the parapet is built.
3.3. No deduction shall be made from quantity of brick work nor did any extra payment make for embedding in
masonry of marking holes in respect of following item.
(1) Ends of joints, beams, posts, girders, rafters, purlins trusses corbel, steps, etc. where cross sectional
area does not exceed 500 Sqcmt.
(2) Opening not exceed in 1000 sq.cm.
(3) Wall plate sand bed plates bearing of slab, chhajjas, and like whose thickness does not exceed 10 cm.
and the bearing does not extend the full thickness of wall.
(4) Drainage holes and recesses for cement concrete blocks to embed hold fasts for doors, window etc.
(5) Iron fixtures, pipes up to 300 mm. dia. hold fasts of doors, and window built into masonry and pipes etc.
for concealed wiring.
(6) Forming charges of section not exceeding 350 Sqcmt in masonry.
(7) Apparatuses for fire places shall not be deducted nor shall extra labor required to make splaying of
jumps, throating and making trenches over the aperture be paid for separately.
3.4. The rate shall before a unit of one cubic meter for brick masonry brick masonry.
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position
complete up to floor two levels (up to 10 ton).
Detailed specification for this item shall be as per General Technical Specifications for Building Works booklet page
No 45 item No 5.4.11 except that T.M.T bar shall be used instead of H.Y.S.D bars.
T.M.T bar shall conform to IS 1786-85 /FE 500D for R.C.C work. It shall be purchased from approved manufacturer
and necessary proof of purchase shall be submitted to Engineer-in-charge along with bill. Bars shall be tested in
Government laboratory or Government approved laboratory prior to use. All necessary tests shall be carried out as
per instruction of Engineer-in-charge.
415 TMT bar shall conform to min 540 Mpa yield strength. TMT bar shall have Tensile strength of minimum 10 %
over YS 570minimum and elongation percentage minimum 18. The chemical composition of TMT bar shall be as
Carbon : 0.25% Maximum
Sulphur : 0.040% Maximum
Phosphorus : 0.040% Maximum
Maximum Sulphur & Phosphorus :0.075% Maximum
1.0 The work shall consist of furnished and placing reinforcement of the shape and dimensions shown on the
drawings or as directed by the Engineer-in-charge.
2.0 Steel shall be clean and free from loose mill scale at the time of fixing in position and subsequent
3.0 Reinforcing steel conform accurately to the dimensions given in the Bar bender schedules shown on
relevant drawings. Bars shall be bent cold to the specified shape and dimensions or as directed by the Engineer-in-
charge using a proper bar bender, operated by hand or power to attain proper radius of bends. Bars shall not be
bent or straightened in a manner that will injure the material. Bars bent during transport or handling shall be
straightened before being used on work; they shall be not heated to facilitate bending. Unless otherwise specified a
'U' type hook at the end of each bar shall invariably provided. The radius of the bend shall not be less than twice
the diameter of the round bar and the length of the straight part of the bar beyond the end of the curve shall be at
least four times the diameter of the round bar. In the case of bars which are not round and in the case of deformed
bars, the diameter shall be taken as the diameter of circle having an equivalent effective area. The hooks shall be
suitably encased to prevent any splitting of the concrete.
4.0 All reinforcement bars shall be accurately placed in exact position shown on the drawings, and shall be
securely held in
position during placing of concrete by annealed binding wire not less than 1 mm. in size and conforming to lS:
and by using stay blocks or metal chairs, spacers, metal hanger supporting wires or other approve devices at
sufficiently close intervals. Bars will not be allowed to sag between supports nor displaced during concreting or any
other operation of the work. All devices used for positioning shall be of non-corrodible material. Wooden and
metal supports will not extend to the surface of concrete, except where shown on the drawings. Placing bars on
layers of freshly laid concrete as the work progresses for adjusting bar spacing will not be allowed. Pieces of broken
stone or brick and wooden blocks shall not be used. Layers of bars shall be separated by spacer bars, precast
mortar blocks or other approved devices. Reinforcement after being placed in position shall be maintained in a
clean condition until completely embedded in concrete. Special care shall be exercised to prevent any
displacement of reinforcement in concrete already placed. To protect reinforcement from corrosion concrete
cover shall be provided as indicated on the drawings. All bars protruding from concrete and to which other bars are
to be spliced and which are likely to be exposed for an indefinite period shall be protected by a thick coat of neat
5.0Bars crossing each other, where required, shall be secured by binding wire (annealed) of size not less than
mm. and conforming to lS: 280 in such a manner that they do not slip overreach
other at the time of fixing and concreting.
6.0 As far as possible, bars of length shall be used. In case this is not possible, overlapping of bars shall be done
as directed by the Engineer-in-charge. When practicable, overlapping bars shall not touch each other, but be kept a
part by 25 mm. or 1.25 times the maximum size of the coarse aggregate whichever is greater, by concrete between
them. Where not feasible, overlapping bars shall be bound with annealed steel wire, and not less than 1 mm.
thickness twisted tight. The overlap shall be staggered for different bars and located at points, along the span
where neither sphere nor bending moment is maximum
7.0 Whenever indicated on the drawings or desired by the Engineer- in-charge bar shall be joined by couplings
which shall have a cross-section sufficient to transits the full stresses of bars, The ends of the bars that are joined
by couplings shall be upset for a sufficient length so that the effective cross-section at the base of threads is not
less than the normal cross-section of the bar. Threads shall be standard white worth threads. Steel for coupling
shall conform to lS:
8. 0 when permitted or specified on the drawings, joints of reinforcement bars shall be butt welded so as to
transmit their full stresses. Welded joints shall preferably be located at points where steel not be subject to more
than 75 percent of the maximum permissible stresses and welds so staggered that, at any one section not more
than 20 per cent of the rods are welded. Only electric is welding using a process which excludes air from the molten
metal and conforms to any or all other special provisions for the work will be accepted. Suitable mean shall be
provided for holding the bars securely in position during welding. It must be ensured that no voids are left in
welding and when welding is done in 2 or 3 stages, previous surface shall be cleaned properly. Ends of the bars shall
be cleaned of all loose scale, rust, grease, paint and other foreign matter before welding. Only competent welder
shall be employed on the work. The M. S. Electrodes used for welding shall conform to lS: 814. Welded pieces of
reinforcement shall be tested. Specimen shall be taken from the actual site and their number and frequency of
tests shall be as directed by the Engineer-in-charge.
9.0 For the purpose of calculating consumption, wastage shall not be permitted beyond 5 percent. Excess
consumption over 5% wilt be charged at penal rate. Useful pieces of steel, as may be decided by the Engineer-in-
charge shall be taken back by the Government at issue rate and at P.W.D. Store from where the steel was supplied.
All the expenses of loading, carting, unloading and returning the waste will be boned by the contractors.
10.0 Reinforcement shall be measured in length including Over-laps, separately for different diameters as
actually used in the work, where welding or coupling is restored to, in place of lap-joints, such joints shall be
measured for payment as the, equivalent length of over-lap as per design requirement. From the length so
measured the weight of reinforcement shall be calculated in tones on the same basis of IS: 1732 even though steel
is supplied to the contractor by the Departmental actual weigh measured. Length shall include hooks at ends.
Wastage and annealed steel wire for binding shall not be measured and cost of these items shall be deemed to be
included in the rates for reinforcement.
11.0 Rate for reinforcement shall include cost of all steel, its carting from source to work site, cutting, bending,
placing, binding and fixing in position as shown on the drawings end as directed by the Engineer-in- charge up to
any floor with all lead and lift . It shall also include cost of all devices for keeping reinforcement in approved
position, cost of jointing as per approved methods and all wastage and spacer bars.
12.0 Rate shall be for a unit of one kilogram including all and fixing up to all floor with all lead
and lift as directed by engineer in charge
Providing 10 mm thick mala cement plaster in single coat on ceiling and soffits of stairs for interior plastering up to
floor two level and finished even and smooth in (ii)Cement mortar 1:4 (1cement :4 sand) mala plastring line , level
and plumb to develop even surface as per instruction of engineer incharge etc complete.
Water M-1. The Cement mortar of proportion 1:4 shall conform to M-13, scaffolding, H frame, machinery tools for
forming the Mala plaster.
The tenderer/ contractor have to execute the exterior textured plaster up to all height and level as per approved
sample and instructed of the engineer in charge
2.1 Scaffolding: Wooden ballies, bamboos, planks, treadles and other scaffolding shall be sound. These shall be
properly examined before erection and use Stage scaffolding shall be provided for ceiling plaster, which shall be
independent of the walls.
2.2 Preparation of back-ground:
2.2.1 The surface shall be cleaned of all dust, loose mortar droppings, traces of algae, efflorescence and other
foreign matter by water or by brushing. Smooth surface shall be roughened by wire brushing if it is not hard and by
racking if it is hard. In case of concrete surface, if a chemical retarded has been applied to the form work, the
surface shall be roughened by wire brushing and all the resulting dust and loose particles cleaned off and care shall
be taken that none of the re trader is left on the surface. Trimming of projections on brick/concrete surface where
necessary shall be carried out to get an even surface.
2.2.2 Raking of joints in case of masonry where necessary shall be allowed to dry out for sufficient period before
carrying out the plaster work.
2.2.3 The work shall not be soaked but only damped evenly before applying the plaster. If the surface becomes dry
such area shall be moistened again.
2.2.4 For external plaster, the plastering operation shall be started from top floor and carried downwards. The
plaster, the plastering operations may be started wherever the building frame and cladding work are ready and the
temporary supporting ceiling resting on the wall of the floor have been removed, Ceiling plaster shall be completed
before starting plaster to walls.
Mode of Measurement & payment
The mode of measurement should be of 1 square meter.
3.1 The rate shall include the cost of all materials, labor and scaffolding etc, involved in the operations described
under workmanship for 15 mm thick mala plaster.
3.2 All plastering shall be measured in square meter unless, otherwise specified length, breadth or height shall be
measured correct to a centimeter.
3.3 Thickness of the plaster shall be exclusive of the thickness of the key i.e. grooves or open joints in brick work,
stone work etc. or space between laths. Thickness of plaster shall be average thickness with minimum 10 mm. at
any point on this surface.
3.4 This item includes plastering up to floor two levels.
3.5 The measurement of wall plastering shall be taken between the walls or partition (dimensions before plastering
being taken) for length and from the top of floor or skirting to ceiling for height. Depth of cover of cornices if any
shall be deducted.
3.6 Soffits of stairs shall be measured as plastering on ceilings, flowing so fits shall be measured separately.
3.7 For jambs, soffits, sills etc. for openings not exceeding 0.5 Sqmt. each in area for ends of joints, beams, posts,
girders, steps etc. not exceeding 0.5 Sqmt. each in area and for openings exceeding 0.5 sq.mt. and not exceeding
3.0 Sqmt in each area deductions and additions shall be made in the following manner :
(a) No deductions shall be made for ends joints, beams posts etc. and openings not exceeding 0.5 Sqmt each and
no addition shall be made for reveals, jambs, so fits, sills etc. of these opening for finish to plaster around ends of
joints, beams, posts etc.
(b) Deduction for openings exceeding 0.5 Sqmt but not exceeding 3 Sqmt. each shall be made as follows and no
addition shall be made for reveals, jambs, so fits etc. sills etc. of these openings.
(i) When both faces of all walls are plastered with same plaster, deduction shall be made for one face only.
(ii) When two faces of wall are plastered with different types of plasters or if one faces is plastered and the other
pointed, deductions shall be made from the plaster or pointing on the side of frame for door, window etc. on which
width or reveals is less than that on the other side but no deductions shall be made on the other side. Where
widths of reveals on both faces of all are equal, deductions of 50% of area of opening on each face shall be made
from area of plaster and/or pointing as the case may be.
3.8 For openings having door frames equal to projecting beyond the thickness of wall, full deduction for opening
shall be made from each plastered face of the wall.
3.9 In case of openings of area above 3 Sqmt each, deduction shall be made for opening but jambs, so fits and sills
shall be measured.
3.10 The rate shall be for a unit of one square meter including all lead and lift.
Applying two coats of Birla or Asian acrylic lippy (putty) and two coats of primer of approved brand and
manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand prepared smooth.
Material : Birla or approved make equivalent brand Lapi, water, approved quality primer, brush, binding material
scaffolding and other tools and manpower .
The contractor has to provide &priming coat over wall surfaces after and including preparing the surface
thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering etc. Complete. And providing and
applying two coats of lappi on wall surface and ceiling with Birla or equivalent brand approved by engineer in
charge incl. thoroughly booming the surface free from mortar dropping and other foreign matter and sand
papering smooth etc Complete. Refer general technical specification book page no 124 item no 19.59 for applying
priming coat over wall surfaces & workmanship only.
Mode of Measurement & payment
The work done shall be measured in square meter for visible area of actual priming work & lappi coating work
done. His payment shall be done on the square meter basis for actual complete item of the Nothing extra shall be
paid for, rubbing, scrapping, finishing, carved surfaces or wastage etc. The rates includes all necessary all lead &
lift , necessary material, operation , consumable , labor , manpower , scaffolding , machinery required to complete
the item in all aspect.
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape
even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc
Primer, weatherproof acrylic emulsion Apex of Asian, Nerolec, Burger or ICI Deluxe brand only primary coat with
alkalis resistance primer , brush ,roller , spray gun scaffolding , water other necessary accessories, plant and
equipment to complete the item . The Asian Paints Apex Ultima Advanced or Asian, Nerolec, Burger or ICI Deluxe
brand Anti Algal Weather Proof Emulsion water-based, modified acrylic, anti algal, high performance exterior wall
finish should be used . The paint should incorporate the latest state-of-the-art technology to provide long-lasting
exterior performance even in the most extreme tropical conditions of .Weatherproof acrylic emulsion paint should
have unique advanced anti algal chemistry ensures that exterior walls and provided with power-packed resistance
against algae and fungi growth. Weatherproof acrylic emulsion must have very good dirt pick up resistance and dirt
cleaning properties
The work of painting shall be done according to IS: 2395(1966) and 1477(1959) and shall be to the entire
satisfaction of the Engineer.
I. External Painting:
a. Preparation of surface: The surface shall be scrapped thoroughly to remove existing Painting or any other
protective film, any major patch or repair or crack shall be cut out and made good as specified under patch
repairing. Cracks may be wetted thoroughly prior to filling or priming paint may be applied to the side of the crack
to avoid undue absorption of water and subsequent shrinkage of filling. Grey and oily spots in the surface should
be removed by approved method. In addition any fungus or mould growth shall be completely removed by
thoroughly scraping and rubbing down with bristle brush and sand paper and then washing down with clean water
and allowed to dry. The surface shall be brushed with a soft bristle brush to remove any dust particle 24 hour after
b. Preparation of color: Shall be prepared strictly as per manufacturer’s instruction.
The primer shall be applied with a brush on the clean dry and smooth surface. Horizontal strokes shall be given first
and vertical strokes shall be applied immediately afterwards. This entire operation will constitute one coat. The
surface shall be finished as uniformly as possible leaving no brush marks. It shall be allowed to dry for at least
hours, before Paint is applied.
The purpose of the primer is to give a better adhesion to the paint and also to reduce consumption of paint on the
wall. Water thin able primers shall be used only. In addition to manufacturer’s instruction, the paint shall be
applied with brushes or spray pumps, if approved, in the specified number of coats. The operation of each coat
shall consist of a stroke of the brush first given horizontally from the right and then from the left and similarly the
subsequent stroke from bottom upwards and other from top downwards. Each coat shall be allowed to dry before
the next coat is applied. No portion of the surface shall be left out to be patched up later on.
The contractor has to providing and Applying two coats of with weatherproof acrylic emulsion alkaline stable,
impregnable, water repellant, on vertical façade by using approved quality material at any height. Contractor has to
do minor repairing of plaster work brick work, pointing at various location without any extra charge. The exterior
surface shall be thoroughly cleaned with water and cleaning material, wire brush so as to remove dust, moss,
fungus etc. Admixture shall be applied as per manufacture specifications, the rate includes the cost of material
applied tools labors involved in applications scaffolding if any cleaning surface and other sundry expense for all
height up to 15 mtr. Other material and specification shall be As per the manufacturer‘s prescribed norms.
Mode of measurement of Payment
The mode of measurement & payments shall be on square meter only. The rate will be inclusive of all material,
labor , lead lift , work up to all height ,tools , scaffolding zula , brush , machinery required to complete the item in
all respect up to satisfaction of architect and engineer in charge both. The unit rate will be per square meters of the
all visible surface and mode of measurement will in square meters only. No other rate , charge will be paid for any
extra work , minor repairing of plaster work or scaffolding to complete the entire item up to satisfaction of
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement:
coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing
flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc.
complete for antiskid Matt finish as per approved sample
Material " Vitrified tiles " /Johnson/ Asian/ Kajaria /Somani brand Vitrified floor tiles antiskid Matt finish
x600, 800 x800 first grade finish in dark and light color, white cement , sand , cement , water , diamond cutter
other plant and machinery etc
S/N Technical Data Norms International Standards Average Value
1 CHEMICAL RESISTACE EN-106 NO DAMAGE NO DAMAGE
2 COLOR RESISTANCE DIN-51094 NO NOTICEABLE COLOR NO DAMAGE
CHANGE MUST TAKE PLACE
3 BREAKING STRENGTH ASTM C- 648 1113N 2829N
4 RESISTANCE TO THERMAL SHOCK EN-104 NO DAMAGE NO DAMAGE
5 SKID RESISTANCE (Bared footed traf) DIN - 51130 R9 R11
6 DETERMINATION OF DIMENSION EN-98
7 SIDES EN-176 0.6
8 THICKNESS OF SIDES EN-179 5
9 STRAIGHTNESS OF SIDES EN-176
10 RECTANGULARITY EN-176
11 SURFACE FLATNESS EN-176
12 WATER ABSORPTION EN-99
13 FLEXION RESISTANCE EN-100 N/ mm3 N/ mm3
14 ABSORPTION RESISTANCE EN-102 205N/ mm3 144N/ mm3
15 FROST RESISTANCE EN-202 NO DAMAGE NO DAMAGE
16 MOH HARDNESS EN-101 6 Moh 8Moh
17 COEFFICIENT OF LINEAR EXPANSION EN-103 9 x 106 C-1 6 x 106 C-1
Vitrified tiles should be of fine vitrified stone ware tie. With the help of highest-pressure computer controlled water
jet driven machines and thanks to specific abrasives, perfect cuts and exclusive combination must be obtained, the
material should be more adaptable malleable and effective. Unglazed with no surface coating. The tiles should be a
Monolithic Homogenous tile. The granite tiles should provides a good sizing and squaring from the factory end
ensures a good flush to flush joint and acid and Alkali resistant, except hydraulic acid and its derivatives the water
absorption must be less than 0.5%, making the tiles highly stain resistant.
2.1.1 The sub grade shall be cleaned, wetted and mopped. The bedding shall then be laid evenly over the surface
tamped and corrected to desired level and allowed to harden enough to offer a rigid cushion to tiles and to enable
the mason to place wooden planks across and squat on it.
2.1.2 The full body vitrified tiles shall be laid on cement mortar bedding of 20mm average and over it thick in cm
1:3. The mortar shall have sufficient plasticity for laying and there shall be no hard lumps that would interface with
the evenness of bedding. The base shall be cleared and well wetted. The mortar shall then be spread in thickness
not less than 10mmat any place and average 20 mm thickness. The proportion of the cement mortar shall be as
specified in the item.
2.2. Fixing full body vitrified tiles:
2.2.1 The full body vitrified tiles before laying shall be soaked in the water for at least two hours. Neat grey cement
grout at 3.3 kg/cement/sqmt of honey like consistency shall be spread over the mortar bedding as directed. The
edges of the tiles are smeared with neat cement slurry. The tiles be well pressed and gently tapped with a wooden
mallet till they are properly bedded and in level with the adjoining tiles. There shall be no hollows in bed or joints.
The joints between the tiles shall be as thin as possible in straight line or as per patterns.
2.2.2. The tiles shall not have staggered joints. The joints shall be true to center line both ways. The column p
coming in the flooring shall be so positioned that its grating shall replace only one tile as far as possible. Where full
size tiles cannot be fixed, they shall be cut (Swan) to the required size and the edges rubbed smooth to ensure
straight and true joints. The joints shall have been filled with white cement grout with wire brush of trowel to a
depth of 5mm. and loose material removed. White cement & matching pigment shall be used for pointing the
joints. After fixing the tile finally in an even plane the flooring shall be kept wet and allowed to nature undisturbed
2.3.1the surplus cement grout that may have come out of the joints shall be cleared off before it sets. Once the
floor has set, it shall be carefully washed, cleared by dilute acid and dried. Proper precaution and measures shall be
taken to ensure that the tiles are not damaged in any way till completion of the construction. Refer general
technical specification booklet page no 84 item no 14.29 for workmanship only
Mode of measurement & payment
3.1 The work done shall be measured in square meter for visible area of actual flooring work done. The length and
width of the flooring shall be measured no between the faces of skirting or dado and plastered face of wall as the
case may be. The paving under dado or skirting shall not be measured. No deduction shall be made for extra paid
for any opening in the floor of area up to 0.1 Sqmt. Nothing extra shall be paid for laying the floors at different
levels in the same rooms. Lying shall be in required pattern as per drawing.
The rate shall be for a unit of one sq. meter. The sample of tiles shall be getting approved from architect. The basic
rate of Vitrified tiles shall be 60 Rs/ Sqft at work site including all cost proof of purchase of tiles shall be given by
contractor to owner. Any lower price then stated above shall be deducted from finished item rate.
Providing and laying Vitrified tiles 8 to 10 mm thick , in skirting risers of steps and dedo on 10mm thick cement
plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry
Material " Vitrified tiles "Bell /Johanson/ Asian/ Kajaria/Varmora brand first grade finish in color & size 600 x
mm , white cement , sand , cement , water , diamond cutter , other plant and machinery etc
S/N Technical Data Norms International Standards Average Value
1 CHEMICAL RESISTACE EN-106 NO DAMAGE NO DAMAGE
2 COLOR RESISTANCE DIN-51094 NO NOTICEABLE COLOR NO DAMAGE
CHANGE MUST TAKE
3 BREAKING STRENGTH ASTM C- 648 1113N 2829N
4 RESISTANCE TO THERMAL SHOCK EN-104 NO DAMAGE NO DAMAGE
5 SKID RESISTANCE DIN - 51130 R9 R11
(Bared footed traf)
6 DETERMINATION OF DIMENSION EN-98
7 SIDES EN-176 0.6
8 THICKNESS OF SIDES EN-179 5
9 STRAIGHTNESS OF SIDES EN-176
10 RECTANGULARITY EN-176
11 SURFACE FLATNESS EN-176
12 WATER ABSORPTION EN-99
13 FLEXION RESISTANCE EN-100 N/ mm3 N/ mm3
14 ABSORPTION RESISTANCE EN-102 205N/ mm3 144N/ mm3
15 FROST RESISTANCE EN-202 NO DAMAGE NO DAMAGE
16 MOH HARDNESS EN-101 6 Moh 8Moh
17 COEFFICIENT OF LINEAR EN-103 9 x 106 C-1 6 x 106 C-1
Vitrified tiles should be of fine vitrified stone ware tie. With the help of highest-pressure computer controlled water
jet driven machines and thanks to specific abrasives, perfect cuts and exclusive combination must be obtained, the
material should be more adaptable malleable and effective. Unglazed with no surface coating. The tiles should be a
Monolithic Homogenous tile. The granite tiles should provides a good sizing and squaring from the factory end
ensures a good flush to flush joint and acid and Alkali resistant, except hydraulic acid and its derivatives the water
absorption must be less than 0.5%, making the tiles highly stain resistant.
2.1.1 the sub grade shall be cleaned, wetted and mopped. The bedding shall then be laid evenly over the surface
tamped and corrected to desired level and allowed to harden enough to offer a rigid cushion to tiles and to enable
the mason to place wooden planks across and squat on it.
2.1.2 the full body vitrified tiles shall be laid on cement mortar bedding of 20mm average and over it thick in cm
1:3. The mortar shall have sufficient plasticity for laying and there shall be no hard lumps that would interface with
the evenness of bedding. The base shall be cleared and well wetted. The mortar shall then be spread in thickness
not less than 10mmat any place and average 20 mm thickness. The proportion of the cement mortar shall be as
specified in the item.
2.2. Fixing full body vitrified tiles:
2.2.1 The full body vitrified tiles before laying shall be soaked in the water for at least two hours. Neat grey cement
grout at 3.3 kg/cement/sq mt of honey like consistency shall be spread over the mortar bedding as directed. The
edges of the tiles are smeared with neat cement slurry. The tiles be well pressed and gently tapped with a wooden
mallet till they are properly bedded and in level with the adjoining tiles. There shall be no hollows in bed or joints.
The joints between the tiles shall be as thin as possible in straight line or as per patterns.
2.2.2. The tiles shall not have staggered joints. The joints shall be true to center line both ways. The column p
coming in the flooring shall be so positioned that its grating shall replace only one tile as far as possible. Where full
size tiles cannot be fixed, they shall be cut (Swan) to the required size and the edges rubbed smooth to ensure
straight and true joints. The joints shall have been filled with white cement grout with wire brush of trowel to a
depth of 5mm. and loose material removed. White cement & matching pigment shall be used for pointing the
joints. After fixing the tile finally in an even plane the flooring shall be kept wet and allowed to nature undisturbed
2.3.1the surplus cement grout that may have come out of the joints shall be cleared off before it sets. Once the
floor has set, it shall be carefully washed, cleared by dilute acid and dried. Proper precaution and measures shall be
taken to ensure that the tiles are not damaged in any way till completion of the construction. Refer general
technical specification booklet page no 84 item no 14.29 for workmanship only
Mode of measurement & payment
3.1 The work done shall be measured in square meter for visible area of actual flooring work done. The length and
width of the flooring shall be measured no between the faces of skirting or dedo and plastered face of wall as the
case may be. The paving under dado or skirting shall not be measured. No deduction shall be made for extra paid
for any opening in the floor of area up to 0.1 sqmt. Nothing extra shall be paid for laying the floors at different
levels in the same rooms. Lying shall be in required pattern as per drawing.
The rate shall be for a unit of one sq. meter. The sample of tiles shall be get approved from architect. The basic rate
of granemite tiles shall be Rs 65/- per sqft at work site including all cost proof of purchase of tiles shall be given by
contractor to owner. Any lower price then stated above shall be deducted from finished item rate.
Providing & lying CERAMIC tiles 6 to 8 mm thick In skirting risers of steps and dado on 10mm. Th. Cement plaster
1:3 (1 cement : 3 coarse sand ) pointing in white cement and jointed with white cement slurry. The tiles should be
approved by engineer in charge and architect , the color and pattern and design as per instruction of architect and
as directed by engineer in charge etc complete with first quality of tiles only fixing up to all and any floor with all
lead & lift etc complete
Ceramic Vitrified cladding tiles , Somani Asian , Kajaria ,Varmora or Johnson make or Equivalent make approved
by architect ,white cement , matching pigment ,send , tiles with concept , butta and border the color and pattern
and design as per instruction of architect material shall be of the best approved quality obtainable and they shall
comply with the respective Indian Standard Specifications. Samples of all materials shall be got approved before
placing order and the approved samples shall be deposited with The Board. Ceramic is primarily made up of clays,
quartziferous sands, glass substances and other minerals.
Only natural raw materials are used, mixed with water and fired at high temperatures to create a naturally
beautiful product and to achieve hardness and durability. Different sizes of ceramic tiles 20x20 cm, 20x 30 cm, 25x
40cm in wall tiles and 30x 30 cm, the tiles should be from ISO 9002 & ISO 14001 certified manufacture only
Conformity of Ceramic Tiles to European Standards EN-177 B-II a /
ISO-13006 and Indian Standard IS :
CEN standards, ISO
Characteristics standards & Indian Minimum Value Method of Testing
Deviation in Length Max. +/- 0.5% Max. +/- 0.5% EN-98 / ISO-10545-2/ IS : 13630 (Part-1)
Deviation in Thickness Max. +/- 0.5% Max. +/- 0.5% EN-98 / ISO-10545.2/ IS : 13630 (Part-1)
Wedging Warpage Max. +/- 0.5% Max. +/- 0.5% EN-98 / ISO-10545.2/ IS : 13630 (Part-1)
Squareness Max. +/- 0.6% Max. +/- 0.6% EN-98 / ISO-10545.2/ IS : 13630 (Part-1)
Water Absorption 3-6% 3-6% EN-99 / ISO-10545.3/ IS : 13630 (Part-3)
Scratch Resistance
Min. 5 Min. 5 EN-101/IS:13630 (Part-13)
As per the abrasion As per the abrasion
Abrasion Resistance class indicated by the class indicated in
manufacturer catalogue
In conformity with the In conformity with the EN-105 / ISO-10545.11/ IS : 13630 (Part-
Crazing Resistance
Resistant to all acids Resistant to all acids
all alkalis (except and alkalis (except EN-122 / ISO-10545.13/ IS : 13630 (Part-
Chemical Resistance
Hydrofluoric Acid and Hydrofluoric Acid and 8)
its compounds) its compounds)
Bending Strength >=220 Kgs./cm2 >=300 Kgs./cm2
Thermal Shock Resistant to 10 Cycles Resistant to 10 cycles
Workmanship for skirting & dado
The joints shall be raked out to a depth of at least 15 mm in masonry walls, while the masonry is being laid. In case
of concrete walls, the surfaces shall be chipped and roughened with wire brushes. The surface shall be cleaned
thoroughly, washed with water and kept wet before skirting work is commenced. Tiles shall be laid on 12 mm thick
plaster of cement mortar 1:3 (1 cement 3 sand) or mix as specified shall be applied and allowed to harden. The
plaster shall be roughened with wire brushes or by scratching diagonally at close intervals while it is green.The tiles
should be soaked in water, washed clean, and a cot of cement slurry applied liberally at the back of tiles and set in
the bedding mortar. The tiles shall be tamped and corrected to proper plane and lines. The tiles shall be set in the
required pattern and but jointed. The joints shall be as fine as possible. Top of skirting of dado shall be truly
horizontal and joints truly vertical except where otherwise indicated. Skirting and dado shall rest on the top of
flooring where full size tiles cannot be fixed thee shall be cut (sawn) to the required size and their edges rubbed
smooth. The tiles should be fixed in the pattern design, color and concept with patta, butta as per instruction of
architect and detail drawing the joints shall be cleaned off the gray cement grout with wire brush or trowel to a
depth of 2 mm to 3 mm and all dust and loose mortar removed. Joints shall then be flush pointed with white
cement added with pigments if required to match the color of tiles. The surface shall then be kept wet for 7 days
after curing the surface shall be washed and finished clean. The finished work shall not sound hollow when tapped
with a wooden mallet. Refer the general specification booklet page no 84 item no 14.32 and other relevant item for
workmanship only. Please refer this entire page for workmanship only not for the mode of measurement and
Mode of Measurement & payment
The work done shall be measured in square meter for visible area of actual skirting, dado, riser of the steps cladding
work done. Nothing extra shall be paid for edge molding , rubbing , finishing ,cutting , wastage includes all
necessary material , operation , consumable , labor , manpower , scaffolding , machinery required to complete the
item in all aspect up to any floor with all lead and lift .
Providing and fixing of minimum 16 mm thick Green marble stone slab for jambs of doors and window .Green
marble stone should be spotless ,without any crack , vain or other damages joined with grey cement slurry and
matching pigment in vertical and horizontal member , including rubbing and polishing and full round edge
moulding on both the sides( edge), Mirror polishing curing of the Green marble stone as per detail design and
instruction. The door frame should have sandwich type Jambs stone fitting to accommodate fixing of door where
required , the fixing of jambs with necessary binding wire tiles piece, adhesive , clamp , fastener, white cement
and matching pigment other consumable, molding and polishing machinery other tools , tackles required to
complete the item. And where two member vertical and horizontal meet it should cut 45 degree angle etc up to all
floor with all lead & lift etc complete. The Green marble stone size and quality should be as per sample approved by
architect and Eng. in charge.
Approved quality Green marble stone slab 16 to 20 mm thick slab, spotless, without any crack, vain or other
damages sand, cement, water , hardware , adhesive , chemical clamp Water shall conform to M-1. Lime mortar
shall conform to M-10. Cement mortar shall conform to M-1). Marble stone slab 16 mm. thick shall conform to M-
2.1 Dressing of Green marble stone slab :
Every stone shall be cut to require size and fine chisel dressed to give a smooth and even surface on all sides to full
depth. A straight edge laid along the sides of the stone shall be fully in contact with it Chisel dressing shall also be
done on top surface to remove any waviness. The sides and top surface of Green marble stone slab shall
be machine rubbed or table rubbed with coarse sand before using. All angles and edges or slabs shall be true,
square and free from chipping.
2.2 The thickness of stone shall be 16 mm. The allowable tolerance shall be 2 mm. allowable. The tolerance shall +
5 mm. in length and breadth.
Bedding of marble slabs shall either be time mortar 1:1.5 (1 lime putty: 1.5 coarse sand) or cement mortar 1:6 (1
cement: 6 coarse sand) of average thickness 20 mm. thick as given in description of item. Minimum thickness at any
place shall not be less than 10 mm.
The surface of sub-grade shall be cleared, wetted and mopped. Mortar of specified mix and thickness shall then be
spread on an area sufficient to receive one marble slab. The slab is washed clean before laying. It tie laid on top
pressed and tapped gently to bring it in level with other slabs. It shall then be lifted and a side. The top surface of
the mortar shall then be corrected by adding fresh mortar at hollows, or depressions. The mortar shall then be
allowed to harden it over this surface cement slurry or honey like consistency at 4.4 Kg. of cement per sq. meter.
The edges of slabs already paved shall be buttered with gray cement. The slab shall then be gently placed in
position and tapped with wooden mallet till it is properly bedded in level with and close to the adjoining slab. The
joints shall be as fine as possible. Surplus cement on the surface of the slab shall be removed. The slab fixed in the
floor adjoining the walls shall enter not less than 10 mm. under the plaster skirting or dado. The junction between
the walls and floors shall be finished neatly. The finished surface shall be true to level and slopes as directed.
2.5. Curing: The floor shall be cured for a minimum period of seven days.
2.6. Polishing and finishing:
Unevenness at the meeting edges of slab shall be removed by fine chiseling. Finishing etc. shall be done as per
relevant specifications of item No. 14.21 (A) ( building specification booklet) or terrazzo tiles flooring except that
cement slurry with/or without pigments shall not be applied on the surface before each polishing.
The contractor has to Provide and Laying Green marble stone slab , spotless ,without any crack , vain or other
damages 16 to 20 mm thick for jambs covering of various window/ opening over 12 mm Thick Cement plaster 1:3
(1 cement : 3 coarse sand ) and joined with grey cement slurry in vertical and horizontal member in the window
opening , or on column cladding , The finishing of joints should be with white cement and matching pigment
including . The rubbing and polishing of the Green marble stone slab on the both side( edge) , mirror polishing on
all visible surfaces and molding on the edges to foam curve smooth surface & fixing up to all height at any level etc
complete up to satisfaction of architect and instruction of engineer in charge.
3.0. Mode of measurements and payment
3.1. Green marble stone slab flooring/skirting fixing in the jambs of door with various kinds of Green marble
stone slab shall be measured in sq. meter. The length and breadth shall be measured between-the finished face of
skirting or dado or wall plaster No deduction shall fie made nor extra shall be paid for nay opening in the floor or
area up to 0.05 Sqmt. Nothing extra shall be paid for laying stone at different levels in the same room. The work
done shall be measured in square meter for visible area of actual door window seal, jams work up to all height and
any level and payment should be in square meter only. Nothing extra shall be paid for, rubbing, finishing, edge
molding, mirror polishing of the Green marble stone slab. This includes all necessary material, operation,
consumable, labor, manpower, scaffolding, machinery required to complete the item in all aspect. The rate shall be
for a unit of one Sqmt.
Providing and fixing of minimum 18 mm thick Marble stone slab of approved quality for flooring , riser of steps,
tread dedo , landing in stair case over Bed of 20mm ( average) thick base of cement mortar 1:6 (1cement :
coarse sand) or lime mortar 1:1.5 laid and jointed with white cement slurry and matching pigment including
rubbing and polishing complete for flooring in steps . The fixing of Black Marble stone slab 18 mm thick at the stair
case steps up to all floor in raiser & tread including edge moulding to flooring and two anti skid grooves as per
instruction of engineer in charge . The fixing of Marble stone slab as per detail design and instruction, including
necessary Mirror polishing , cutting of the stone , adhesive , clamp , fastener , other consumable and labour and
fixing up to all floor with all lead & lift etc complete as directed by engineer in charge
Water shall conform to M-1. Lime mortar shall conform to M-10. Cement mortar shall conform to M-1). Green
Marble stone slab 25 mm thick of Kesaraji or Udaipur green as per approved sample.
2.0. Workmanship
2.1. Dressing of slabs :
Every stone shall be cut to require size and fine chisel dressed to give a smooth and even surface on all sides to full
depth. A straight edge laid along the sides of the stone shall be fully in contact with it Chisel dressing shall also be
done on top surface to remove any waviness. The sides and top surface of marble
Slabs shall be machined rubbed or table rubbed with coarse sand before using. All angles and edges or slabs shall
be true, square and free from chipping. The green marble shall to fix in stair case without joint in single piece on
each step riser and trade with edge molding on front side 2.2 the thickness of stone shall be 25 mm. The allowable
tolerance shall be 2 mm. allowable. The 'tolerance shall + 5 mm. in length and breadth.
Bedding of marble slabs shall either be time mortar 1:1.5 (1 lime putty : 1.5 coarse sand) or cement mortar 1:6 (1
cement : 6 coarse sand) of average thickness 20 mm. thick as given in description of item. Minimum thickness at
any place shall not be less than 10 mm.
The green marble shall to fix in stair case without joint in single piece on each step riser and trade with edge
molding on front side .The surface of sub-grade shall be cleared, wetted and mopped. Mortar of specified mix and
thickness shall then be spread on an area sufficient to receive one marble slab. The slab be washed clean before
laying. It tie laid on top pressed and tapped gently to bring it in level with other slabs. It shall then be lifted and a
side. The top surface of the mortar shall then be corrected by adding fresh mortar at hollows, or depressions. The
mortar shall then be allowed to harden it over this surface cement slurry or honey like consistency at 4.4 Kg. of
cement per sq. meter. The edges of slabs already paved shall be buttered with gray cement. The slab shall then be
gently placed in position and tapped with wooden mallet till it is properly bedded in level with and close to the
adjoining slab. The joints shall be as fine as possible. Surplus cement on the surface of the slab shall be removed.
The slab fixed in the floor adjoining the walls shall enter not less than 10 mm. under the plaster skirting or dedo.
The junction between the trade and riser of steps shall be finished neatly. The finished surface shall be true to level
and slopes as directed.
2.5. Curing : The floor shall be cured for a minimum period of seven days.
2.6. Polishing and finishing:
Unevenness at the meeting edges of slab shall be removed by fine chiseling. Finishing etc. shall be done as per
relevant specifications of item No. 14.21 (A) or terrazzo tiles flooring except that cement slurry with/or without
pigments shall not be applied on the surface before each polishing.
3.0. Mode of measurements and payment
3.1. Marbles stone flooring with various kinds of marble shall be measured in sq. meter. The length and breadth
shall be measured between-the finished surface of marble No deduction shall fie made nor extra shall be paid for
nay opening in the floor or dado or area up to 0.05 sq. mt. Nothing extra shall be paid for laying stone at different
levels in the any floor up to 40 meter height. Treads and steps of stairs paved with marble stone slabs shall be also
be measured under flooring.
3.2. The rate shall be for a unit of one sq. meter for fixing of The green marble in stair case without joint in single
piece on each step of riser and trade with edge molding on front side, up to all floor and level with all lead and lift.
Providing and fixing minimum 50mm wide sand blasting on Marble stone for stair case steps with necessary tools
tacjels , equipment plant as per detail design upto all floor with all lead & lift etc complete as per instruction of
engineer in charge
1.0 25mm thick textured ( sand blasting)Green marble
1.1. Water shall conform to M-1. Lime mortar shall conform to M-10. Cement mortar shall conform to M-11
Polished Green marble shall conform to textured ( sand blasted ) Green marble , The Green marble shall be hard
even, sound, and regular in shape and generally uniform in color. The color of the stone shall generally be green
Brown coloured shall not be allowed for use They shall be without any soft veins, cranks of flaws.
1.2. The size of the stones to be used for flooring shall be of size 600 mm x 600 mm and/or size 600 mm. x 450 mm
as directed However smaller sizes will be allowed to be used to the extent of maintaining required pattern.
Thickness shall be as specified
1.3. The edges of minus 30 mm on accounts of chisel dressing of edges shall be permitted for length as well as
breadth. Tolerance in thickness shall be + 3 mm
1.4. The edges of stones shall be truly chiseled and table rubbed with coarse sand before paving. All angles and
edges of the stones of shall be true, square and free from chipping and surface shall De true and plain 1.5. When
machine cut edges are specified, the exposed and the edges at joints shall be machine cut The thickness of the
exposed machine cut edges shall be uniform
1.6 The textured ( sand blasting)kota st stones shall have sand blasted surface. When brought on site, the stones-
shall be single polished or double polished depending upon its use. The stones for paving shall generally be single
side sand blasted The stones to be used for dedo, skirting, sink, veneering, sills steps etc. where machine polishing
after the stones are fixed in situ is not possible shall be double sand blasted.
2.0. Workmanship
2.1. Each sand blasted slab shall be cut to the required size and shape and fine chisel dressed at all the edges. The
trust dressed shall have a full contract if a straight edge is laid along. The sides shall be table rubbed with coarse
sand before paving. All angles and edges of the slabs shall be true square and free from chippings and giving a
plane surface. The thickness
shall be 25 mm. (Average) as specified in the item but not less than 20 mm. at any place of the slab.
2.2. Bedding for the sand blasted Green marble shall be of cement mortar 1:6 (1 cement : 6 coarse sand) or L.M.
1:1.5 of average thickness 20 mm given in the description of the item. Sub grade shall be cleaned, wetted and
mopped Mortar of the specified mix and thickness shall then be spread on an area sufficient to receive one kota
stone slab. The slab shall be washed clean before laying. It shall be laid on top, pressed, tapped gently to bring it in
level with the other slabs. If shall then be lifted and laid aside. Top surface of the mortar shall then be corrected by
adding fresh mortar at hollows or depressions. The mortar shall then be allowed to harden bit. Over this surface,
cement slurry of honey-like consistency shall be applied. The slab shall then be gently placed in position and tapped
with wooden mallet till it is properly padded in level with and close to the adjoining slab. The joint shall be as fine
as possible. The slabs fixed in the floor adjoining, the walls shall enter not less than 10 mm. under the plaster,
skirting or dedo. The junction between the wan and floor shall be finished neatly. The finished surface shall be true
to levels and slopes as directed
2.3. The floor shall be kept wet for a minimum period of 7 days so that bedding and joints set properly
2.4. Polishing shall be normally commenced after 14 days of laying the stone slab. The sand blasting should be done
with using proper compress and sand blasting gun as per standard norms . the polishing shah be done with
carborundum stones of 120 grade grit fitted in the heavy machine and then second polishing shall be done with
carborundum stone of 220 to 350 grade grit fitted in heavy machine. Water shall be properly used during polishing.
The stone shall then be washed clean with water When directed by the Engineer-in-charge, wax polish of approved
quality shall be applied on the surface with the help of soft cloth over a clean and dry surface. Then the polishing
machine fitted with bobs shall be run over it.
2.5. The holes required for Nahni traps, pipes and any other fittings shall be made, without any extra cost.
3.0. Measurement & payment
3.1. The rate shall include the cost of all materials and labor involved in ail the operations described above. The
sand blasted Green marble flooring shall be measured in square meters correct to two places decimal, length and
breadth shall be measured correct to a centimeter and between the finished face of skirting dedo plaster and no
deduction shall be made nor extra paid for any opening in floor of areas up to 0 1 sq
3.2. The rate shall be for a unit of one sq. meter
Mode of Measurement & payment
The work done shall be measured in square meter for visible area of actual flooring work done. The length and
width of the flooring shall be measured no between the faces of skirting or dado and plastered face of wall as the
case may be. The paving under dado or skirting shall not be measured. No deduction shall be made for extra paid
for any opening in the floor of area up to 0.1 sqmt. Nothing extra shall be paid for laying the floors at different
levels in the same rooms. Lying shall be in required pattern as per drawing.
The rate shall be for a unit of one sq. meter. The sample of sand blasted Green marble be getting approved from
architect. And engineer in charge
Applying general insecticide pest control treatment to floors, cupboards etc including labour material etc.
complete. Using Heptachloride 20 EC. As Per 6113_ pests Consentration Weight 0.50 percent is recommended one
litre chemical emulsion dillute with 39 liter of water will give. Total dillute concrentration will be 40 litre inclusive of
one litre chemical emulsion appication 0.5 Litre chemical / Sqm of surface is recommended as per I.S.
Bifenthrin (Biflex) TC manufactured by FMC USA and Premise IMIDACLOPRID 30.5% solvent concentration
manufactured Bayer India Ltd. water ,solution other tools plant machinery etc complete
The contractor has to Apply the general anti termite treatment for pre construction horizontal barrier , vertical
barrier and treatment to external perimeter by carrying out ant termite treatment through authorized service
center of Godrej Hicare Ltd. Using Bifenthrin (Biflex) TC manufactured by FMC USA and Premise IMIDACLOPRID
30.5% solvent concentration manufactured Bayer India Ltd. The anti termite treatment to post construction to
floors, walls /door frames , cupboards electrical boards , plumbing lines etc as per detail specification and
instruction of engineer in charge .The tenderer/ controtor shall use the approved quality chemical of the Godrej
brand . Mixing ratio should be as specified by the manufacture and as approved by the engineer in charge A daily
record shall be maintained by the Contractor indicating the amount of work done and the quantity of chemical
consumed for the work. This record book shall be the property of the Employer. Method of application The
following paragraphs specify the manner and sequence of operation, which must be followed. They also indicate
the rates of application of chemicals of stated concentration for various operations. It shall be distinctly understood
that these represent the minimum rates of application for each operation and that the Contractor shall actually
apply chemicals at rates higher than those specified herein to the extent he may consider them necessary for
effectiveness during the 7 years guarantee period. In other work the onus of Responsibility of applying adequate
amount of chemicals as required to sustain the 7 years guarantee shall be that of the Contractor, but in no case
shall actual rates of application be less than these specified herein. i) The bottom and sides of foundation pits shall
be treated to a height of 300 mm at the rate OF 5 Liters of 1% solution of chemical in water per square meter .ii)
The refill earth shall be treated at the rate of 5 liters of 1% solution of the chemical in water per linear meter on
both sides of built up walls. iii) Before laying the floor, the top surface of the consolidated earth within the plinth
wall shall be treated at the rate of 5 liters of 1% solution of the chemical in water per square meter. It is advisable
to make 20mm dia 500mm deep holes at the rate of 300 mm c/c before pouring the chemical.iv) After completion
of the building the 300mm of earth along the external perimeter of the building shall be treated at the rate of
liters of 1% solution of the chemical in water per square meter.v) All timber faces in contact with masonry work as
in door frames shall be brushed twice with 1% solution of the chemical in kerosene oil.vi) Treatment shall not be
made when the soil or fill is excessively wet or immediately after heavy rains to avoid surface flow of the toxicant
from application site. Unless the treated areas are to be immediately covered, precautions shall be taken to
prevent disturbance of the treatment by human or animal contact with the treated soil.Guarantee: 7 years.
In the unlikely event of any treatment becoming necessary subsequently during the guarantee period, required
inspection and treatment shall be carried out free of cost. The Contractor shall submit an undertaking to the
Employer, on a stamp paper, duly notarized, to carry out such repairs as and when required.
2.0. Workmanship
2.1. The chemicals barrier shall be complete and continuous under whole of the structure to be protected.
2.2. The bottom and the sides of foundations up to a height of 30 cms. from the bottom of excavation
made for masonry foundation and for basement column pits shall be treated with the chemical emulsion at
the rate 5 liters/ sq. meter of the surface area. .
2.3. The chemical treatment shall be-carried out when the surfaces is quite dry. Chemical treatment shall not be
carried out when it is raining or when the soil wet with rain or sub soil water.
2.4. Once formed, treated soil berries shall be not disturbed. If by chance, treated soil barriers are disturbed,
immediate steps shall be taken to restore the continuiting and compactness of the barrier system
2.5. The treatment against termite infection shall remain fully effective for a period not less than 7 years from
date of issue of the final certificate to completion of work. If at any time during this period, any defects in
revealed or any evidence of infection in any part of the building or structure is noticed, the contractor shall be
the concerned defects within 14 days on receipt of notice from Engineer-in-charge. On contractor's failure to do so,
the Engineer-in-charge may get the same rectified through any other agency at contractor's risk and cost, and
decision of Engineer-in-charge as to the cost payable by contractor for the same shall be final and binding to the
2.6. A guarantee bond on appropriately stamped paper shall be given by the contractor to the department in the
manner and form prescribed below:
FORM OF GUARANTEE BOND
I/We………………………………………………………………………………. ( Contractor) hereby guarantee that work
will remain unaffected and will not be any way damaged by termite or any other germs of similar types, for a
10 years after completion of the work of anti-termite as per the terms and conditions of the contract and or
that might be caused on account of termite and or other similar type of germs and hereby Guarantees to make
any loss of damages suffered by the Government of Gujarat and further guarantee to redo effective work without
claiming any extra cost.
2.7. This guarantee shall remain in force for the period of 7 years from the completion of the work under the
contract and it shall remain binding to the contractor for period of 7 years.
2.8. The deposit at the rate of 50% of the cost of this item from the running and final bills shall be recovered and
retained for the first one year after completion of the work and 10% shall be retained for the balance of guarantee
period and shall be refunded only after the completion of the guarantee period.
3.0. Mode of measurements & payment
3.1. The length and breadth shall be measured correct to a cm. as per the dimensions of sanctioned plans. No
deduction shall be made nor extra paid for any opening for pipes etc. up to 0.1.sq. mt. The rate shall include the
of all labour and materials required for the operation involved for satisfactory completion of this item. The sides of
trenches 30 cms, each side and bottom shall be measured under this item. The rate shall be for a unit of One sq.
meter of entire item complete in all respect. any charge , wastage or extra shall not be paid separately. The
contractor has signed 7 year performance bond before the final bill.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water
proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen
primer for bitumen membrane @0.40 ltr/sqm. by the same membrane manufacture of density at 25 C, 0.87-0.89
kg/ltr and viscocity 70-160 cps. Over the primer coat the layer membrane shall be laid using Butane torch and
sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the
membrane shall be as under : Joints strength in logitudinal and transverse direction at 23 C as 650/450N/5cm. Tear
strength in longitudinal and transverse direction as 300/250N/. Softening point of membrence not less than 150 C.
Cold flexibility shall be upto -2 C when tested in accordance with ASTM, M-5147. The laying of membrane shall be
got done through the authorized applicator of the manufacturer of membrane : (with 5 years service guarantee
APP attpftic polymerized polymer bituminize membrane with polyester reinforcement , Bituplus P or membrane or
Roof seal Polymer Modified Membrane With Non-woven Polyester Re-enforcement bitumen roof seal pre-
fabricated polymer modified bitumen membrane ,roof seal pre in forced with anon-woven polyester fabric, Roof
seal P. is reinforced with polyester fiber mat. The reinforcement is impregnated and coated on both sides with
polymer modified bitumen. bitumen roof seal membrane should be used for waterproofing applications on roofs,
NominalRollLength:10Mtrs. Nominal RollWidth:1MNominal Thickness :3,MM Reinforcement :Non-woven
polyester/Glass fiber mat Installation tools required Gas torch, Knife ,Trowel ,Measuring tape , Marking string,
Gloves , scaffolding , tools and manpower required to complete the job
The Contractor has to supply and apply the APP modified 3 mm thick waterproofing membrane granular finished
which consist a coat of bitumen primer for membrane on terrace with ultra violet resistance and working up to any
height with the 7 years of guaranty against any leakage The material and workmanship should produce the product
with total impermeability ,Good bond ability & sea integrity ,Stability at high temperature ,Good flexibility
Compatible with all normal roofing and building components ,The Bitumen Roof seal should be installed by torch
welding method fully bonded to substrate. Laps are bonded together. Peripheries and protrusions are sealed
according to specifications. The Coverage rate shall be minimum Flat are as:
1.15M2/M2perlayerwith10cms.sidelapsand15cms.end laps. Baseflashing: 100x35cms.with15cm. End laps,
0.40M2/Linear M Averagewastage:3-5%( Rate may vary as per site requirement up to 2%) The underside of the
membrane should be torched just enough to superficially melt the bitumen. Excessive heating may damage there
reinforcement. Overlaps should be re-heated from the top and resealed with a trowel to ensure integrity. The
details of installation method sand flashing requirements, as per relevant BITUMAT systems Design and Installation
Manual and as per instruction of engineer in charge In addition to stringent regular tests by BITUMAT laboratory,
the product should be tested periodically by Independent laboratories.
Roof seal Polymer Modified Membrane with Non-woven Polyester Reinforcement
Property Typical Value Test
Roofseal"P" Roofseal"G"
1 Reinforcement Polyester Glass fiber
2 Softeningpoint°C 150 20 650/450
3. Penetration@25°Cdmm 40/45 300/250 Noflow
4. Tensile strength, L/T,N/5 CM@23°C 0-(-2) 150
6. Tear strength/T,N No flow 0-(-2) ASTMD
7. Heatresistance,@80°C ASTMD5 ASTMD ASTMD
8. Cold flexibility, °C ASTMD5147 ASTMD ASTMD
9 Lap joint strength L/T,N/5 CM@23°C 650/450 350/300 CGSB-37-
Mode of measurement & payment:
The entire work will be measured in square meter basis and rate will be paid on per square meter basis only. The
entire work is to be carried out up to the satisfaction of architect /engineer in charge. The rate is inclusive of all
tools ,tackles ,fabrication ,wastage , overlapping , scaffolding and necessary civil work and all lead and lift up to any
height and everything to complete the work in perfect manner .The 2.5% of the total completed project cost should
be withheld with the client as a special deposit for guaranty warranty against any leakage , seepage form
waterproofing treated surface and release only after the 7 year.
Providing and laying broken China Mosaic Flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles
to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar crème out up to surface
using white cement including rounding off junctions and extending them up to 15cm along the wall, clearing with
water and oxalic acidic. as directed.
Water shall not be salty brackish and shall be clean reasonably clear and free objectionable quantities of silt and
traces of oil j\injurious alkalis salts organic matter and other deleterious material which will either weaken the
mortar of concrete or cause efflorescence or attack the steel in R C C container for transport storage and huddling
of water shall be clean, Water shall confirm to the standard specified in I S 455 -1978
If required by the Engineer in charge it shall be tested by comparison with distilled water compression shall be
made by means of standard cement tests for soundness time of setting and mortar strength as specified in I S 269-
1976 Any indication of unsoundness charge in time of setting by 30 minutes or more or decrease of more than
percent strength of mortar prepared with distilled water sample when compared with the result obtained with
mortar prepared with distilled water shall be sufficient cause for rejection of water under test.
Water for curing mortar concrete or masonry should not be too acidic or too alkaline
It shall be free of elements which significantly affect the hydration reaction or otherwise interface with the
hardening of mortar or concrete during curing or those which produce objectionable stains or other unsightly
deposits on concrete or mortar surfaces Hard and bitter water shall not be used for curing
Potable water will generally found suitable for curing mortar or concrete
Cement shall be ordinary Portland slag cement as per IS 1624 -1974 or Portland slag cement as per IS 455-1976
Cement shall be stored above the ground level in perfectly dry and water tight sheds. Wherever bulk storage
containers are used, their capacity should be sufficient to cater to the requirements at site and should be cleaned
at least once every 3 to 4 months. The aggregate shall be stored in such a way as to prevent admixture of foreign
materials. Different size of fine or coarse aggregate shall be stored in separate stockpiles sufficiently away from the
each other to prevent inter mixing the materials.
Sand shall be natural sand, clean well graded, hard strong durable and gritty particular free from immures amounts
of dust, clay, kankar modules, soft: or flaky particles shall alkali salts, organic matter, learn mica or other
deleterious substance and shall be got approved from the Engineer-in-charge. The sand shall not contain more than
8 percent of slit as determined by field test. if necessary the sand. Coarse Sand: The fineness modules of coarse
sand shall not be less than 2.5 and shall not exceed 3.0. The sieve analysis of coarse sand be as under:
I. S. Sieve Designation % by wt. passing
S. Sieve Designation % by wt. passing
FINE SAND: The fineness module shall not exceed 1.0 the sieve analysis of fine sand be as under:
I. S. Sieve Designation % by wt. passing
Materials shall be stored as to prevent their deterioration of their quality and fitness for the work. Any material
which has deteriorated or has been damaged or is otherwise considered defective by the Engineer-in-charge shall
not be used in the work.
Water proofing compound
Water proofing compound shall be of approved quality and make as approved by Engineer in charge
Brick bat aggregates shall be broken form well burnt or slightly over burnt and dense bricks it shall be
homogeneous in texture roughly cubical in shape clean and fee from dirt or any other foreign material brick bats
shall be of 40 to 50 mm nominal size unless otherwise specified in the item the under burnt or over burnt bricks
bats shall not be used
Mosaic tile pieces
China mosaic tiles pieces shall be of 50 mm to 90 mm nominal size. tile pieces shall be made from hard and good
quality fully treated oven back fine quality of tiles of various approved color .
White cement shall be of approved make it shall confirm definition of I S 8042 –E- 1978 the sample of white cement
shall be approved by Engineer in charge
First of all surface of the entire terrace shall be cleaned by thoroughly booming and then by wire brushes All the
loose material dust and de brigs shall be removed thoroughly for the entire surface of the terrace All joints and
cracks shall be racked off and cut in v trench which shall be filled by neat cement slurry admixed with water
proofing compound The joints with parapet shall be racked up to 30 cm height and shall be applied by neat cement
slurry admixed with water proofing compound Neat cement slurry shall be prepared and a water proofing
compound of approved make shall be mixed with the slurry in proportion specified by the manufacturer of the
compound and shall be laid throughout the surface of the terrace by the use of brushes mala etc Cement slurry
shall be prepared by adding adequate quantity of water so as to spread it uniformly on the surface.
After two days of proper curing applying a second coat of cement slurry on entire surface of the terrace the entire
surface shall be finished with 20 mm thick C M 1:4 and china mosaic tilling in true level and slope as directed by
Engineer in charge & finally finishing the surface with trowel with white cement slurry (specification of white glaze
tiles flooring shall be followed for the execution of this item.)
Finishing the surface with 20 mm thick C M 1:4 and china mosaic tilling & finally finishing the surface with trowel
with white cement slurry
After two days proper curing the terrace shall be flooded for 15 days.
MODE OF MEASUREMENT & PAYMENT:
The unit rate flooring shall include the cost of all materials, tools and plant required for mixing, laying of base layer
in true level and slope as required applying & placing stones in position, compacting, finishing, curing mirror
polishing, providing treatment of 30 cm high all over the length of parapets and corners and sill of doors etc, and all
other incidental expenses for producing flooring work to complete the structure or its components as shown on the
drawings and according to these specifications. They shall also include the cost of making, fixing and removing of all
scaffolding and forms required for the work. The rate of plastering shall include the cost of all labor, materials tools
and plant scaffolding and all incidental expenses as described herein above.
The work shall be measured for its length and width, limiting dimensions to those specified on plan or as directed.
The rate shall be for a unit of one square meter. The payment will be made on square Meter basis of the finished
Providing erecting and fixing double coated Syntex PVC. (ISI) water tank of required capacity each with all
necessary fittings and connection etc. complete on terrace.
POLYETHYLENE WATER STORAGE TANKS
Polyethylene used for manufacture of tanks and manhole lids may be high density (HDPE), low density (LDPE) or
liner low density (LLDPE) and shall conform to IS: 10146. Polyethylene shall be compounded with carbon black so as
to make the tank resistant to ultra violet rays from the sun. The percentage of carbon black content in Polyethylene
shall be 2.5+0.5 percent and it shall be uniformly distributed. The materials used for the manufacture of tank,
manhole lid and fittings shall be such that they neither contaminate the water not impart any taste, color, odor or
toxicity to water.
MANUFACTURE AND FINISH
The tanks shall be manufactured by rotational molding process. Each tank and the manhole lid shall be single piece
having arrangement for fixing and locking the manhole lid with the tanks. Excess material at the mould parting line
and near the top rim shall be neatly cut and finished. The internal and external surface of the tanks shall be
smooth, clean, and free from hidden internal defects like air bubbles, pit and metallic or other foreign material
inclusion. Capacity of the tank, minimum weight of the empty tank (without manhole lid) and the manufacture
brand name shall be embossed on the top surface of the tank near manhole.
SHAPE, SIZE AND CAPACITY
The tank shall be cylindrical vertical with closed top having a manhole. Diameter and height of the tank of various
capacities shall be as per manufacturer’s specification and a clearance of + 3 percent shall be permitted on these
dimensions. Capacity of the tank or up to the bottom of the inlet location whichever is less. Capacity of the tank
shall be specified. Extra Capacity if any shall be ignored.
WEIGHT AND WALL THICKNESS
Minimum weight of the empty tank (Exclusive of manhole lid fittings) and the minimum wall thickness of top,
bottom and sides shall be specified in Table 1 Wall thickness shall be checked beyond 150 mm of the edge where
the direction of the plane of tank surface changes.
INSTALLATION AND FITTINGS
The flat base of the tank shall be fully supported over its whole bottom area on a durable rigid flat and level
platform sufficiently strong to stand without deflection the weight of the tank when fully filled with water.
Depending upon the capacity and location tanks may be suitably anchored as per the directions of the Engineer-in-
charge. For inlet, outlet and other connections with hexagonal check nuts and washers on either side of the tank
wall shall be provided. Holes for threaded connections shall be drilled and not punched. Pipes entering or leaving
the tank shall be provided with unions and suitably supported on a firm base to avoid damage to the tank walls.
The lid shall rest evenly and fit over the rim of the manhole so as to prevent the ingression of any foreign matter
into the tank. The lid shall be provided with suitable arrangement for locking it with the tank. The tank and its
components shall conform to the local bye-laws for prevention of mosquito menace.
Dimensions shall be measured to the measured to the nearest cm and weight of the empty tank shall be recorded
to the nearest 100g. Capacity of the tank as defined in 20.24.3 shall be calculated to the nearest liter.
S.NO CAPACITY LITRES MINIMUM WALL THICKNESS mm MINMUM WEIGHT OF EMPTY TANK Kg
Mode of Measurement & payment
The mode of measurement shall be on liter basis only for the complete item The rate shall including the cost of the
tank, manhole lid, carriage and delivery at the place specified. Hoisting, installation, fittings, platform and anchoring
shall be payable separately. The rate shall be for a unit of one liter.
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure polythene pipes of the following
outside Dia. Low density, complete with special flange compression type fittings, wall clips etc. including making
good the wall ceiling and floor.(G)110 mm etc complete with proper wall clamping of Rain water pipe up to all floor
level with all lead and lift as per instruction of engineer in charge
Un plasticized - PVC molded fittings Bend 87.5° of 110 mm diameter, solution, clamp, adhesive, solvent cement etc
The contractor has to provide and fix the un plasticized - PVC molded fittings of Bend 87.5° of 110 mm diameter for
un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A .The contractor /tenderer has to perform
jointing of bend and pipe with seal ring conforming to IS : 5382 and leaving 10 mm gap for thermal expansion . .
The pipes and fitting shall be accurately cut. The ends of the pipes and fittings should be absolutely free from dirt
and dust. The outside surface of the pipes and the inside of the fittings shall then be roughened with emery paper,
and then solvent cement joint. Since solvent cement is aggressive to P V.C. care must be taken to avoid applying
excessive cement to the inside of pipe sockets as any surplus cement cannot be wiped off after jointing. Empty
solvent cement tins, brushes, rags, or paper impregnated with cement should not be buried in the trenches. They
should be gathered not left scattered about, as-they can prove to be a hazard to animals, which may chew them. If
any manufacturer recommends its own methods of jointing the same shall be adopted after necessary approval
from the Engineer-in-charge. The contractor has to fix the un plasticized - PVC molded fittings of Bend 87.5° of
mm diameter of Astral Dutron Prince, as per the instruction of engineer in charge up to sixth floor with all lead and
Mode of Measurement & payment
The unit rate shall be for a unit of each and payment shall be made for the unit of each including all to complete the
item in all aspect up to 30 meter height with all lead and lift as per instruction of engineer in charge.
Providing and fixing stainless steel chicken mesh jali at specific location between R.C.C. and brick masonry joints
including fixing ,nailing while executing plastering on the various surface at any height including all labor &
material to complete. Chicken mesh jali should be maximum 20 cm only. the item as directed by engineer in charge
1.0. Materials : galvanized low carbon wire, annealed wire. Mesh size (distance between the faces of the hexagon )
from 13 to 20mm.The diameter of the wire mesh from 0.6 to 2.0mm.Delivered in rolls, roll width 1m to 2.5m and
roll length 50m, 100m, 200mand other material like hardware screw nails , consumable conform to relevant IS
2.0. Workmanship : The contractor /tender have to provide and fix the Chicken wire mesh at specific location of
RCC/ Brickwork joint. The Chicken wire mesh should have specific properties for plastering use. The Chicken wire
mesh shall be formed by twisting two adjacent wires at least four times, forming a strong honeycomb mesh
structure. So, it has a high strength and durability. Even if a place is cut off, it will not lead to the entire chicken
mesh structure destroyed. While using for plastering, plaster layer and the reinforcing metal layer have different
thermal expansion coefficient. Therefore, subject to extreme changes in temperature, chicken wire (durable
twisted woven mesh - no rigid mesh) is more acceptable for plastering. Using Chicken wire mesh when plastering
effectively prevents plaster layer drying out and cracking. Its hexagonal shape prevents the formation of internal
stresses. Due to its flexibility structure, chicken wire is convenient for mounting on curved and angled surfaces. Its
other benefits are twisted mesh improved corrosion resistance and no risk of injury at work. As its special physical
and mechanical properties, chicken wire is perfectly suited for reinforcement plastering in construction,
reinforcement waterproofing, leveling floors and facade work. The minor civil including fixing base coat and
finishing coat of plaster work shall be done at the time of finishing as per instruction of engineer in charge
3.0. Mode of measurements and payment : 3.1. The Chicken wire mesh shall measure including all along its fixing
in square meter. No allowance shall be made for the work for cutting, wastage, fixing, minor civil work up to all lead
and lift. 3.2. The rate includes the cost of all materials and labour involved in all the operations including providing
and fixing of sandwich type Chicken wire mesh in plastering. 3.3. The rate shall be for a unit of one square meter of
Providing and fixing window having extruded aluminum Colour anodized section frame main outer size
x38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal two track member size 61.85 mm x 31.75 mm x 1.20mm @
wt.of 0.695 Kg/mt, vertical member of size 61.85 mm x 31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with sliding
shutters of horizontal member size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, vertical member of size40mm x
18mm x 1.29mm @ wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with 5 mm thick transparent bronze colour tinted float
glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per
details etc complete for window.
aluminum section having Color anodized section frame main outer size 63.50 x38.10 x 1.95 mm,@ Wt 1.094 Kg /
Rmt, horizontal two track member size 61.85 mm x 31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt, vertical member of
size 61.85 mm x 31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with sliding shutters of horizontal member size 40mm x
18mm x 1.29mm @ wt.of 0.456Kg/mt, vertical member of size40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, @
Wt. 0.457 Kg/mt with 5 mm thick transparent bronze colour tinted float glass with powder coated aluminum
fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc complete for window.
including providing anodized aluminum handle & stopper, aldrop & mortise lock, SS screw with fixture & fastening
with glazing Patti rubber packing including brass pivot hinges, silicon sealant handles with locking arrangement
etc. complete with anodized fixtures and fastenings,
The contractor has to provide and fixing the extruded aluminum four track window having extruded aluminum
Colour anodized section frame main outer size 127mm x 38.10mm x 1.35mm (of Jindal Section no:2443,@
Wt.1.384 Kg/mt),horizontal Four track member size 122.20mm x 31.75mm x 1.10mm (of Jindal Section no:8787,@
Wt. 1.205 Kg/mt),vertical member of size 122.20mm x 31.75mm x 1.50mm (of Jindal Section no:8935,@ Wt.
Kg/mt) with sliding shutters of horizontal member size 40mm x 18mm x 1.29mm (of Jindal Section no:8949 @ wt.of
0.456Kg/mt),vertical member of size 40mm x 18mm x 1.29mm (of Jindal Section no:8947 @ wt.of
0.456Kg/mt/Section 8948,@ Wt. 0.457 Kg/mt). The sliding shutter should be glazed with 5 mm thick transparent
bronze colour tinted float glass. The sliding shutter should be with anodized or powder coated aluminum fittings
and fixtures and other consumable accessories and hardware . the transparent silicon sealant should be used for
glass fixing to frame as per details.The work shall be carried out through an approved specialist contractor, who
shall furnish all materials, labor, accessories, equipment, tools and plant and incidentals required for providing and
installing anodized/powder coated aluminum, windows, claddings, louvers and other items as called for on the
drawings. The drawings and specifications cover the major requirement only. The supplying of additional
fastenings, accessory features and other items not mentioned specifically herein, but which are necessary to make
a complete installation shall be a part of this contract.
General:- Aluminum windows etc. shall be of sizes, section details as shown on the drawings. The details shown on
the drawings indicate generally the sizes of the component parts and general standards. These may be varied
slightly to suit the standards adopted by the manufacturer. Before proceeding with any manufacturing, the
contractor shall prepare and submit complete manufacturing and installation drawings for approval of the Engineer
and no work shall be performed until the approval of these drawings is obtained.
Shop Drawings:-
The contractor shall submit the shop drawings of doors, windows, louvers, cladding and other aluminum work,
based on architectural drawings, to the Engineer for his approval. The drawings shall show full size sections of
doors, windows etc. thickness of metal (i.e. wall thickness), details of construction, sub frame / rough ground
profile, anchoring details, hardware as well as connection of windows, doors and other metal work to adjacent
work. Samples of all joints and methods of fastening and joining shall be submitted to the Engineer for approval
well in advance of commencing the work.
Samples of doors, windows, louvers etc. shall be fabricated, assembled and submitted to the Engineer for his
approval. They shall be of sizes, types etc. as decided by Engineer. All samples shall be provided at the cost of the
Minimum doors and windows shall be fabricated from extruded section of profiles of detailed on drawings. The
sections shall be extruded by the manufacturers approved by the Engineer. The aluminum extruded sections shall
conform IS designation 63400-WP (HV9WP Old designation) with chemical composition and technical properties as
per IS: 733 and IS:1285. The permissible dimensional tolerance of the extruded sections shall be such as not to
impair the proper and smooth function / operation and appearance of doors and windows.
HSCC WP & OTHER ASSOCIATED WORKS Spec Page-C- 6 of CPWD booklet
Doors, Windows, etc. shall be fabricated to sizes as shown, as shown, at factory and shall be of section, size
combinations and details as shown in the Architectural Drawings. All doors, windows etc. shall have mechanical
joints. The joints shall be designed to withstand a wind load of 150 kgs. Per sqm. The design shall also ensure that
the maximum. All members shall be accurately machined and fitted to form hairline joints prior to assembly. The
joint and accessories such as cleats, brackets, etc. shall be of such material as not to cause any bimetallic action, the
design of the joints and accessories shall be such that the accessories are fully concealed. The fabrication of doors,
windows, etc. shall be done in suitable sections to facilitate easy transportation, handling and installation.
Adequate provision shall be made in the door and window members for anchoring to support and fixing of
hardware and other fixtures as approved by the Engineer.
For fixed portion, the aluminum angle cleat used shall be 38mm x 38mm x 4.8mm size and minimum 50mm long.
The quantity of minimum 0.9m length shall be used for 39.13 kg. of extruded sections fabricated.
For shutters of doors, windows and ventilators, aluminum angle cleat used shall be of the size mentioned above
having minimum length of 35mm. Minimum 0.42 m length of angle cleat shall be used for 20.21 kg. of extruded
sections fabricated. No extra payment shall be made for using such quantity of cleat as mentioned in para
All aluminum sections shall be anodized as per IS:7088 and to required color if specified in the item as per IS;1868
grading as specified in item schedule after cutting the member to requisite sizes before the final assembly.
Anodizing to conform to specified grade with minimum average thickness of 15 microns when measured as per
IS:612. The anodic coating shall be properly sealed by steams or in boiling water are cold sealing process as per
IS:1868/IS:6057. Polythene tape protection shall be applied on the anodized section before they are brought to
site. All care shall be taken to ensure surface protection during transportation, storage at site and installation. The
tape protection shall be removed on installation. The sample will be tested in the approved laboratory and cost of
samples, cost of testing, shall be borne by the contractor.
PROTECTION OF FINISH:-
All aluminum members shall be wrapped with approved self adhesive non-staining PVC tapes.
HSCC WP & OTHER ASSOCIATED WORKS Spec Page-C-
HANDLING AND STACKING:-
Fabricated materials shall be stacked in an approved manner to protect the material against any damage during
transportation. The loading and unloading shall be carried out with utmost care, on receipt of materials at site,
they shall be carefully examined to detect any damaged pieces. Arrangements shall be made for expeditious
replacement of damaged pieces / parts. Materials found to be acceptable on inspections shall be repacked in crates
and stored safely.
In the case of composite windows and doors, the different units are to be assembled first. The assembled
composite units should be checked for line, level and plumb before final fixing is done. Units may be serial
numbered and identified as how to be assembled in their final location of situation so warrants.
Where aluminum comes into contact with masonry brickwork, concrete, planter or dissimilar metals, it shall be
coated with approved insulation lacquer, paint or plastic tape to ensure that electro-chemical corrosion is avoided.
Insulation material shall be trimmed off to a clean flush line on completion.
The contractor shall be responsible for assembling composite, bedding and filling the groove with polysulphide
sealant inside and outside, at the transoms and mullions, placing the doors, windows etc. in their respective
openings. After the doors / windows have been fixed in their correct assigned position, the open hollow sections
abutting masonry concrete shall be fitted with approved polysulphide sealant densely packed and neatly finished.
The contractor shall be responsible for doors, windows, etc. being set straight plumb, level and for their satisfactory
operation after fixing is complete.
Just prior to installation the doors, windows, etc. shall be uncrated and stacked on edge on level bearers and
supported evenly. The frame shall be fixed into position true to line and level using adequate number of expansion
machine bolts, anchor fasteners of approved size and manufacturer and in an approved manner. The holes in
concrete / masonry members for housing anchor bolts shall be drilled with an electric drill.
The doors, windows assembled as shown on drawings shall be placed in correct final position in this opening and
marks made on concrete members at jambs, sills and heads against the holes provided in frames for anchoring. The
frame shall then be removed from the opening and laid aside. Neat hole with parallel sides of appropriate size shall
then be drilled in the concrete members with an electric drill at the marking to house the expansion bolts. The
expansion bolts shall then be inserted in the holes, struck with a light hammer till the nuts are forced into the
anchor shell. The frame shall then be placed in final position in the opening and anchored to the support through
cadmium plated machine screws of required size threaded to expansion bolts. The frame shall be set in the
opening by using wooden wedges at supports and be plumbed in position. The wedges shall invariably be placed at
meeting points of glazing bars and frames.
HSCC WP & OTHER ASSOCIATED WORKS Spec Page-C-
NEOPRENE GASKETS:-
The contractor shall provide and install Neoprene gaskets of approved size and profile at all locations as shown and
as called for to render the doors, windows etc. absolutely air tight and weather tight. The contractors shall produce
samples of the gaskets for approval and procure after approval only.
Hinges, stays, handles, tower bolts, locks and other fittings shall be of approved quality and manufacturers shall be
approved by the Engineer.
MANUFACTURER’S ATTENDANCE:-
The manufacturer immediately prior to the commencement of glazing shall adjust and set all windows and doors
and accept responsibility for the satisfactory working of the opening frames.
MASTIC CEMENT:-
The gaps between frames and supports and also any gaps in the door and windows section shall be raked out as
directed and filled with mastic cement of approved color and make to ensure complete water tightness. The mastic
cement shall be of such color and composition that it would not stain the masonry / concrete work, shall receive
paint without bleeding, will not sag and shall not set hard or dry out under any conditions of weather. The samples
of mastic cement to be used for this purpose shall be got approved by the Engineer before its actual use.
DETAILS OF TESTS:-
The various tests on aluminum sections shall be conducted in accordance with the relevant IS codes. The minimum
number of tests for anodic coating and corrosion resistance shall be asgiven below:-
DETAILS NO. OF TESTS
(i)Doors, Windows & Ventilators 5% of Nos manufactured.
The samples of major member of each unit of doors / windows shall be selected at random by Engineer as such
that all the aluminum section shall be got tested. 2.15.4 Work shall be carried out as per CPWD Specifications -
1996 Vol.I to Vol. VI with correction slips 1 to 8 unless specified.
PROTECTION & CLEANING:-
The sub-contractor shall adequately protect all components and accessories from damage during shipments,
storage at jot site, erection and after completion of the work. At such
HSCC WP & OTHER ASSOCIATED WORKS Spec Page-C-
time as may be directed, the sub-contractor shall remove all protective tapes or coating, thoroughly clean all
anodized/powder coated aluminum and glass surfaces with suitable cleaning agent, make final adjustments to all
ventilators, etc. and hardware leaving all in first class working order.
SCOPE OF WORK:-
The sub-contractor shall design, supply, fabricate, deliver and install and guarantee all construction necessary to
provide a complete aluminum composite panel cladding, complete with all necessary anchors, hardware and
fittings to provide a total installation, fully in conformity with the requirements and intent of the drawing and
specification herein. The scope of work shall be read in conjunction with those in the specification of structural
ACCEPTANCE CRITERIA:-
The aluminum sections shall conform to the provisions of the relevant item of BOQ. For payment purposes only
actual weight of sections shall be taken into account. If, however, the sectional weight of any aluminum section is
higher than the permissible variation then the weight payable shall be restricted to the weight of the section
including permissible variation.
Measurement: Payment by weight shall be made for aluminum sections including beading only and all fixing angles,
fittings / fixtures such as handles and hinges etc. shall not be included in the weight to be paid.
GUARANTEE BOND: All aluminum work shall carry two years guarantee after completion of the work against water
leakage, unsound material and workmanship and defective anodizing as per approved Performa. Two years
guarantee in prescribed Performa must be given by the specialized firm, which shall be counter signed by the
contractor, in token of his overall responsibility in addition 10% (Ten Percent) of the cost of these items would be
retained as guarantee to which the performance of the work done. The cost guarantee against this item of work
shall be in addition to the security deposit mentioned elsewhere in the contract form. If any defect is noticed
during the guarantee period, it should be rectified by the contractor within seven days, and if not attended to, the
same will be got done from another agency at the risk and cost of the contractor. However, this security deposit
can be released in full, if bank guarantee of equivalent amount for two years is produced and deposited with the
Work shall be carried out as per CPWD Specifications - 1996 Vol.I to Vol. VI with correction slips 1 to 6 unless
Mode of measurement & payment
Rate shall be for a unit of square meter basis of the complete item of anodize aluminum fully /partly glazed door.
The measurement of the square meter should be cross checked with the weight of the aluminum section used in
per square meter. The weight of the 1 square meter anodize aluminum partly paneled partly glazed door should be
minimum as per standard Jindal section weight kg/square meter. The weight of glass, rubber gasket, handle and
other accessories shall not be considered while calculating weight. The contractor / tenderer have to produce the
authentic weight slip showing the correct and actual weight of the aluminum section. The rate of the item shall
include the cost of all materials, T&P, Double Scaffolding and labor, water charges, minor, civil work , wastage etc.
required in all the above operations and item complete in all aspect up to satisfaction of architect
Providing and fixing aluminum Panelled single/double door Partly Glazed & Partly with 12 mm thick both side pre
laminated Particle Board with Frame having extruded aluminum color anodized section frame main Frame size
101.60 mm x 44.45 mm x 3.18mm ( of Section No.20011 @ wt. of 2.54 kg/mt )unit providing shutters of bottom &
Top rail- 114.30 mm x 25.40 mm x 3.18mm (of Section No.19511 @ wt. of 2.65 kg/mt ) Shutter Middle rail =
mm x 44.45 x 2.65 mm (of Jindal Section No.20002 @ wt. of 2.79 kg/mt) Vertical member Shutter style = 85.00 mm
x 44 mm x 3.00(of Jindal Section No.19509 @ wt. of 1.51 kg/mt).with 12mmth. both side pre laminated particle
board (novapan) conforming to IS: 12823 Grade 1 Type II in paneling fixed in aluminium door consisting of outer
frame shutter as per design with two pairs of standard handles, two pair of concealed shoot bolts 250mm long and
pin type narrow style lock and thumb turn from the other side, including all fixtures, fastening etc. complete as
directed and as per drawing and design. Rate including hinges/Pivots and making provision for fixing of fitting
wherever required including the cost of EPDM rubber/neoprene gasket required Anodized aluminium (work for all
Aluminum section of frame 63.50 mm X 49.50 mm @1.15 kg/m & shutter top rail & styles size 47 mm x 44 mm Wt
@ 0.88 kg/ m, Bottom rail size114 mm x 44mm Wt @1.36 kg/m & lock rail size rail size114 mm x 44mm Wt @1.36
kg/m and glazing clips size 19 mm x17 mm Wt @ 0.124 kg/m , 5 mm thick frosted or obscured (Modi Float or Saint
Gobain brand) shutter frame style size 44.5 mm X 44.5 mm of 1.30 kg/ rmt weight , both side laminated plywood
sheets , glazing Patti rubber gasket packing brass pivot, hinges, handles with locking arrangement , anodized
aluminum handle & stopper, aldrop & mortise lock, SS screw with fixture & fastening anodized fixtures and
fastenings ,hardware and other consumable
The contractor has to provide and fixing the fully partly paneled partly glazed door having anodized aluminum
single/Double leaf door standard section (Jindal or Equivalent) for frame 63.50 mm X 49.50 mm @1.15 kg/m . The
door shutter top rail & styles should be of size 47 mm x 44 mm having Wt @ 0.88 kg/mtr and Bottom rail size
mm x 44mm Wt @1.36 kg/mtr & lock rail size rail size114 mm x 44mm having Wt @1.36 kg/m . The glazing clips
size should be 19 mm x17 mm having Wt @ 0.124 kg/mtr. The shutter should be glazed with 5 mm thick frosted or
obscured on one side glass (Modi Float or Saint Gobain brand) at top and bottom panel. The glass should be fixing
with neoprene rubber gasket and fix by glazing clips. The providing and fixing of door including anodized
aluminum handle & stopper, aldrop & mortise lock, SS screw with fixture & fastening. The item includes minor civil
work, cutting the flooring, making good etc. The aluminum door including frame should be supply and fix with
required materials, consumable, hardware labors and equipments as per detailed drawing or as directed Engineer
Extant and Intent:-
The work shall be carried out through an approved specialist contractor, who shall furnish all materials, labor,
accessories, equipment, tools and plant and incidentals required for providing and installing anodized/powder
coated aluminum, windows, claddings, louvers and other items as called for on the drawings. The drawings and
specifications cover the major requirement only. The supplying of additional fastenings, accessory features and
other items not mentioned specifically herein, but which are necessary to make a complete installation shall be a
part of this contract.
General:- Aluminum windows etc. shall be of sizes, section details as shown on the drawings. The details shown on
the drawings indicate generally the sizes of the component parts and general standards. These may be varied
slightly to suit the standards adopted by the manufacturer. Before proceeding with any manufacturing, the
contractor shall prepare and submit complete manufacturing and installation drawings for approval of the Engineer
and no work shall be performed until the approval of these drawings is obtained.
Shop Drawings:-
The contractor shall submit the shop drawings of doors, windows, louvers, cladding and other aluminum work,
based on architectural drawings, to the Engineer for his approval. The drawings shall show full size sections of
doors, windows etc. thickness of metal (i.e. wall thickness), details of construction, sub frame / rough ground
profile, anchoring details, hardware as well as connection of windows, doors and other metal work to adjacent
work. Samples of all joints and methods of fastening and joining shall be submitted to the Engineer for approval
well in advance of commencing the work.
Samples of doors, windows, louvers etc. shall be fabricated, assembled and submitted to the Engineer for his
approval. They shall be of sizes, types etc. as decided by Engineer. All samples shall be provided at the cost of the
Minimum doors and windows shall be fabricated from extruded section of profiles of detailed on drawings. The
sections shall be extruded by the manufacturers approved by the Engineer. The aluminum extruded sections shall
conform IS designation 63400-WP (HV9WP Old designation) with chemical composition and technical properties as
per IS: 733 and IS: 1285. The permissible dimensional tolerance of the extruded sections shall be such as not to
impair the proper and smooth function / operation and appearance of doors and windows.
HSCC WP & OTHER ASSOCIATED WORKS Spec Page-C- 6 of CPWD booklet
Doors, Windows, etc. shall be fabricated to sizes as shown, as shown, at factory and shall be of section, size
combinations and details as shown in the Architectural Drawings. All doors, windows etc. shall have mechanical
joints. The joints shall be designed to withstand a wind load of 150 kg/Sqmt. The design shall also ensure that the
maximum. All members shall be accurately machined and fitted to form hairline joints prior to assembly. The joint
and accessories such as cleats, brackets, etc. shall be of such material as not to cause any bimetallic action, the
design of the joints and accessories shall be such that the accessories are fully concealed. The fabrication of doors,
windows, etc. shall be done in suitable sections to facilitate easy transportation, handling and installation.
Adequate provision shall be made in the door and window members for anchoring to support and fixing of
hardware and other fixtures as approved by the Engineer.
For fixed portion, the aluminum angle cleat used shall be 38mm x 38mm x 4.8mm size and minimum 50mm long.
The quantity of minimum 0.9m length shall be used for 39.13 kg. of extruded sections fabricated.
For shutters of doors, windows and ventilators, aluminum angle cleat used shall be of the size mentioned above
having minimum length of 35mm. Minimum 0.42 m length of angle cleat shall be used for 20.21 kg of extruded
sections fabricated. No extra payment shall be made for using such quantity of cleat as mentioned in Para
All aluminum sections shall be anodized as per IS:7088 and to required color if specified in the item as per IS;1868
grading as specified in item schedule after cutting the member to requisite sizes before the final assembly.
Anodizing to conform to specified grade with minimum average thickness of 15 microns when measured as per IS:
612. The anodic coating shall be properly sealed by steams or in boiling water are cold sealing process as per IS:
1868/IS: 6057. Polythene tape protection shall be applied on the anodized section before they are brought to site.
All care shall be taken to ensure surface protection during transportation, storage at site and installation. The tape
protection shall be removed on installation. The sample will be tested in the approved laboratory and cost of
samples, cost of testing, shall be borne by the contractor.
PROTECTION OF FINISH:-
All aluminum members shall be wrapped with approved self adhesive non-staining PVC tapes.
HSCC WP & OTHER ASSOCIATED WORKS Spec Page-C-
HANDLING AND STACKING:-
Fabricated materials shall be stacked in an approved manner to protect the material against any damage during
transportation. The loading and unloading shall be carried out with utmost care, on receipt of materials at site,
they shall be carefully examined to detect any damaged pieces. Arrangements shall be made for expeditious
replacement of damaged pieces / parts. Materials found to be acceptable on inspections shall be repacked in crates
and stored safely.
In the case of composite windows and doors, the different units are to be assembled first. The assembled
composite units should be checked for line, level and plumb before final fixing is done. Units may be serial
numbered and identified as how to be assembled in their final location of situation so warrants.
Where aluminum comes into contact with masonry brickwork, concrete, planter or dissimilar metals, it shall be
coated with approved insulation lacquer, paint or plastic tape to ensure that electro-chemical corrosion is avoided.
Insulation material shall be trimmed off to a clean flush line on completion.
The contractor shall be responsible for assembling composite, bedding and filling the groove with polysulphide
sealant inside and outside, at the transoms and mullions, placing the doors, windows etc. in their respective
openings. After the doors / windows have been fixed in their correct assigned position, the open hollow sections
abutting masonry concrete shall be fitted with approved polysulphide sealant densely packed and neatly finished.
The contractor shall be responsible for doors, windows, etc. being set straight plumb, level and for their satisfactory
operation after fixing is complete.
Just prior to installation the doors, windows, etc. shall be uncrated and stacked on edge on level bearers and
supported evenly. The frame shall be fixed into position true to line and level using adequate number of expansion
machine bolts, anchor fasteners of approved size and manufacturer and in an approved manner. The holes in
concrete / masonry members for housing anchor bolts shall be drilled with an electric drill.
The doors, windows assembled as shown on drawings shall be placed in correct final position in this opening and
marks made on concrete members at jambs, sills and heads against the holes provided in frames for anchoring. The
frame shall then be removed from the opening and laid aside. Neat hole with parallel sides of appropriate size shall
then be drilled in the concrete members with an electric drill at the marking to house the expansion bolts. The
expansion bolts shall then be inserted in the holes, struck with a light hammer till the nuts are forced into the
anchor shell. The frame shall then be placed in final position in the opening and anchored to the support through
cadmium plated machine screws of required size threaded to expansion bolts. The frame shall be set in the opening
by using wooden wedges at supports and be plumbed in position. The wedges shall invariably be placed at meeting
points of glazing bars and frames.
HSCC WP & OTHER ASSOCIATED WORKS Spec Page-C-
NEOPRENE GASKETS:-
The contractor shall provide and install Neoprene gaskets of approved size and profile at all locations as shown and
as called for to render the doors, windows etc. absolutely air tight and weather tight. The contractors shall produce
samples of the gaskets for approval and procure after approval only.
Hinges, stays, handles, tower bolts, locks and other fittings shall be of approved quality and manufacturers shall be
approved by the Engineer.
MANUFACTURER’S ATTENDANCE:-
The manufacturer immediately prior to the commencement of glazing shall adjust and set all windows and doors
and accept responsibility for the satisfactory working of the opening frames.
MASTIC CEMENT:-
The gaps between frames and supports and also any gaps in the door and windows section shall be raked out as
directed and filled with mastic cement of approved color and make to ensure complete water tightness. The mastic
cement shall be of such color and composition that it would not stain the masonry / concrete work, shall receive
paint without bleeding, will not sag and shall not set hard or dry out under any conditions of weather. The samples
of mastic cement to be used for this purpose shall be got approved by the Engineer before its actual use.
DETAILS OF TESTS:-
The various tests on aluminum sections shall be conducted in accordance with the relevant IS codes. The minimum
number of tests for anodic coating and corrosion resistance shall be asgiven below:-
DETAILS NO. OF TESTS
(i)Doors, Windows & Ventilators 5% of Nos manufactured.
The samples of major member of each unit of doors / windows shall be selected at random by Engineer as such
that all the aluminum section shall be got tested. 2.15.4 Work shall be carried out as per CPWD Specifications -
1996 Vol.I to Vol. VI with correction slips 1 to 8 unless specified.
PROTECTION & CLEANING:-
The sub-contractor shall adequately protect all components and accessories from damage during shipments,
storage at jot site, erection and after completion of the work. At such
HSCC WP & OTHER ASSOCIATED WORKS Spec Page-C-
time as may be directed, the sub-contractor shall remove all protective tapes or coating, thoroughly clean all
anodized/powder coated aluminum and glass surfaces with suitable cleaning agent, make final adjustments to all
ventilators, etc. and hardware leaving all in first class working order.
SCOPE OF WORK:-
The sub-contractor shall design, supply, fabricate, deliver and install and guarantee all construction necessary to
provide a complete aluminum composite panel cladding, complete with all necessary anchors, hardware and
fittings to provide a total installation, fully in conformity with the requirements and intent of the drawing and
specification herein. The scope of work shall be read in conjunction with those in the specification of structural
ACCEPTANCE CRITERIA:-
The aluminum sections shall conform to the provisions of the relevant item of BOQ. For payment purposes only
actual weight of sections shall be taken into account. If, however, the sectional weight of any aluminum section is
higher than the permissible variation then the weight payable shall be restricted to the weight of the section
including permissible variation.
Measurement: Payment by weight shall be made for aluminum sections including beading only and all fixing angles,
fittings / fixtures such as handles and hinges etc. shall not be included in the weight to be paid.
GUARANTEE BOND: All aluminum work shall carry two years guarantee after completion of the work against water
leakage, unsound material and workmanship and defective anodizing as per approved Performa. Two years
guarantee in prescribed Performa must be given by the specialized firm, which shall be counter signed by the
contractor, in token of his overall responsibility in addition 10% (Ten Percent) of the cost of these items would be
retained as guarantee to which the performance of the work done. The cost guarantee against this item of work
shall be in addition to the security deposit mentioned elsewhere in the contract form. If any defect is noticed
during the guarantee period, it should be rectified by the contractor within seven days, and if not attended to, the
same will be got done from another agency at the risk and cost of the contractor. However, this security deposit
can be released in full, if bank guarantee of equivalent amount for two years is produced and deposited with the
Work shall be carried out as per CPWD Specifications - 1996 Vol.I to Vol. VI with correction slips 1 to 6 unless
Mode of measurement & payment
Rate shall be for a unit of square meter basis of the complete item of anodize aluminum partly paneled partly
glazed door. The measurement of the square meter should be cross checked with the weight of the aluminum
section used in per square meter. The weight of the 1 square meter anodize aluminum partly paneled partly glazed
door should be minimum 1.3 kg/square meter. The weight of glass, rubber gasket, handle and other accessories
shall not be considered while calculating weight. The contractor / tenderer have to produce the authentic weight
slip showing the correct and actual weight of the aluminum section. The rate of the item shall include the cost of all
materials, T&P, Double Scaffolding and labor, water charges, minor, civil work, wastage etc. required in all the
above operations and item complete in all aspect up to satisfaction of architect.
Providing and fixing in position collapsible steel shutters with vertical channels 20 x 10 x 2 mm braced with flat iron
diagonals 20 x 5 mm size with top and bottom rails of T_rin 40x 40 x 6 mm with 38mm dia, steel pulleys complete
with bolts, nuts, locking arrangements, stoppers handles including applying a priming coat of red lead paint
Providing and fixing of decorative stainless steel SS 304 Non magnetic best quality Railing as per approved sample.
The SS304 Railing shall be fix on the edge or periphery of staircase & steps as per detail design and instruction .The
top horizontal SS pipe should be of 50 mm Diameter with minimum 16/14 gauge pipe thickness and in between
two horizontal pipe 25 mm diameter with minimum 16/14 gauge pipe thickness , the vertical pillar pipe shall be of
50mm diameter with minimum 14/12 gauge pipe wall thickness , including SS pipe bending , SS 304 square
sandwich and distance peace for fitting & assembly at extension joint as per detail design . The Providing and fixing
of SS railing including cutting, fabrication ,SS arc welding, grinding , erection , fixing with necessary machinery
tools, tackles, labor and required civil work as per detail design at specific location The SS 304 pipe railing should be
fixed in the floor/ wall by means of pipe socket , bush ,flange, bullet S.S bolt, S.S L end key and other necessary
hardware and consumable required to complete in all aspect . The item includes buffing, polishing , assembling of
the different unit of SS pipe Railing and required civil work for the fixing of the SS 304 railing up to all floor in
perfect position etc complete as per approved sample as directed by engineer in charge..
Stainless Steel SS 304 of Salem Steel Pipe, angle, flat, rod & other section should be non magnetic conforming to IS
specification. The thickness of Stainless steel shall not be less than 0.56mm at any point after manufacture.
MARKING: Marking shall be as per relevant clauses of specification. No.IND/GS.1777 Or as per relevant IS code
NOTE: Chemical composition of Stainless Steel 304 grade is as follows:
Mechanical Tests, Malleability Test, Tensile Test, Pressure Test, Alignment Test, Visual Inspection
Chemistry Data : [top] Carbon 0.08 max ,Chromium 18 - 20 ,Iron Balance ,Manganese 2 max ,Nickel 8 -
Phosphorus 0.045 max ,Silicon 1 max ,Sulphar 0.03 max Principal Design Features One of the most widely used
and oldest of the stainless steels. This was originally called 18-8 which stood for its chromium and nickel content. It
possesses an excellent combination of strength, corrosion resistance and fabric ability. It is available in the widest
variety of forms and sizes of any stainless steel.
Mach inability Slow speeds and heavy feeds will minimize this alloys tendency to work harden. Due to long
stringy chips, the use of chip breakers is advisable. Many companies now offer premium mach inability grades, such
as CarTech with their Project 70 and 7000 series. Welding all fusion and resistance processes have been
successfully employed in welding 304. AWS E/ER308 or 312 filler metal is recommended. For cleaner, stronger
welds, may users choose 304L which has a controlled low carbon content designed to reduce carbide precipitation
at the weld boundaries. Hot Working Forging, heading and other hot working should follow uniform heating to
2100-2300 F (1149-1260 C). Rapid cooling is necessary to attain maximum corrosion resistance in finished parts.
Cold Working Readily fabricated by most cold working methods, 304 may require intermediate annealing to avoid
cracking or tearing from radical deformation. Full annealing should follow any operation to reduce internal stress
and optimize corrosion resistance. Annealing 1850-2050 F (1010-1121 C) followed by rapid cooling. Hardening
This alloy does not respond to heat treatment. Cold work will cause an increase in both hardness and strength.
Physical Data: [top] Density (lb / cu. in.) 0.285 Specific Gravity 7.9 Specific Heat (Btu/lb/Deg F - [32-212 Deg F])
0.12 Electrical Resistively (microhm-cm (at 68 Deg F)) 432 Melting Point (Deg F) 2650 Modulus of Elasticity
Tension 28 Grade 304L, the low carbon version of 304, does not require post-weld annealing and so is extensively
used in heavy gauge components (over about 6mm). Grade 304H with its higher carbon content finds application at
elevated temperatures. The austenitic structure also gives these grades excellent toughness, even down to
cryogenic temperatures. Key Properties These properties are specified for flat rolled product (plate, sheet and coil)
in ASTM A240/A240M. Similar but not necessarily identical properties are specified for other products such as pipe
and bar in their respective specifications. Composition, typical compositional ranges for grade 304 stainless steels
are given in table 1.Mechanical Properties, Typical mechanical properties for grade 304 stainless steels are given in
table 2., Table 2. Mechanical properties of 304 grade stainless steel Grade Tensile Strength (MPa) min Yield
Strength 0.2% Proof (MPa) min Elongation (% in 50mm) min Hardness Rockwell B (HR B) max Brinell (HB) max
Physical Properties Typical physical properties for annealed grade 304 stainless steels are given in table 3.Table
Physical properties of 304 grade stainless steel in the annealed condition Grade Density (kg/m3) Elastic Modulus
(GPa) Mean Coefficient of Thermal Expansion (mm/m/°C) Thermal Conductivity (W/m.K) Specific Heat 0-100°C
(J/kg.K) Electrical Resistively (nW.m) Grade Specification Comparison Approximate grade comparisons for
stainless steels are given in table 4.Corrosion Resistance Excellent in a wide range of atmospheric environments
and many corrosive media. Subject to pitting and crevice corrosion in warm chloride environments, and to stress
corrosion cracking above about 60°C. Considered resistant to potable water with up to about 200mg/L chlorides at
ambient temperatures, reducing to about 150mg/L at 60°C. , Heat Resistance, Good oxidation resistance in
intermittent service to 870°C and in continuous service to 925°C. Continuous use of 304 in the 425-860°C range is
not recommended if subsequent aqueous corrosion resistance is important. Grade 304L is more resistant to
carbide precipitation and can be heated into the above temperature range., Grade 304H has higher strength at
elevated temperatures so is often used for structural and pressure-containing applications at temperatures above
about 500°C and up to about 800°C. 304H will become sensitized in the temperature range of 425-860°C; this is not
a problem for high temperature applications, but will result in reduced aqueous corrosion resistance., Heat
Treatment, Solution Treatment (Annealing) - Heat to 1010-1120°C and cool rapidly. These grades cannot be
hardened by thermal treatment. Welding excellent weld ability by all standard fusion methods, both with and
without filler metals. AS 1554.6 pre-qualifies welding of 304 with Grade 308 and 304L with 308L rods or electrodes
(and with their high silicon equivalents). Heavy welded sections in Grade 304 may require post-weld annealing for
maximum corrosion resistance. This is not required for Grade 304L. Grade 321 may also be used as an alternative to
304 if heavy section welding is required and post-weld heat treatment is not possible.
Machining, A "Ugima" improved mach inability version of grade 304 is available in bar products. "Ugima" machines
significantly better than standard 304 or 304L, giving higher machining rates and lower tool wear in many
operations. Dual Certification, It is common for 304 and 304L to be stocked in "Dual Certified" form, particularly in
plate and pipe. These items have chemical and mechanical properties complying with both 304 and 304L
specifications. Such dual certified product does not meet 304H specifications and may be unacceptable for high
temperature applications.
The metal should be preferably be good soft SS 304, sound
and clean, free from injurious cold shuts or blow holes, true
to size & shape and of excellent finish. Sample pieces of 35 kg
/cm2 for span of 140 cms (1 inch square must be capable of
sustaining on a clear span of 4ft 6inch a central load of
lbs) when test in pipe. Sharp corners should be well rounded,
the grinding to be done by grinder and to made smooth and
finished. Complete in all respect to the satisfaction of
engineer in charge.
The entire work should be carried out as per the design and drawing which includes supplying, testing, fabrication,
cutting, bending, welding, fixing, polishing, buffing, joining, minor civil work and other work related to installation
of SS 304 pipe railing. The joining of the separate elements should be as per design. One master sample should be
prepared in actual in full size and only after the approval the railing should be made as per sample should be
approved by engineer in charge before commencing the work. The consistency in the weight should be there and
the tolerance will in tune of about 2 percentages.
The complete work shall be buffed by buffing machine for glossy and Matt finish as per detail design as directed by
engineer in charge. Necessary hold fast, fixtures and fasteners should be of good quality approved make and shall
as per directed by engineer in charge.
Mode of measurement and payment
The measurement will be in terms of kilogram and payment will be made per unit rate of kilogram of the complete
item including minor civil work for fixing the gill/railing .The rate includes fixing of the pipe railing at any floor level
up to any height and on wall or column faces. The sample piece of one railing/ grill panel shall be got prepared and
get it approved from architect. Work shall be carried out as per approved sample. As this is pipe work, necessary
samples of various types of pipes and support members shall be kept in to Board office
Providing and fixing MS grill of required pattern to frames of window etc. with MS flats at required spacing and
frame around square or round bar with round headed bolts and nuts or by screw ( B ) Ornamental grill/Jali (Similar
item) as detail design with two coats of primer & enamel paints , the shed and color as per instruction of engineer
in charge etc complete.
Approved quality Mild steel bright bar, rod, hollow pipe, various section and other material, primer, synthetic oil
paint scaffolding, machinery plant etc
The contractor has to Provide and fix the MS bright grill of required pattern to frames of window duct covering of
tower as per detail design and architectural drawing. Includes, cutting, bending, welding, fabrication, fixing the grill
on any height of the building at desired location as per instruction of engineer in charge. The grill shall be of plain
and light ornamental grill as detail design as per instruction of architect etc complete. in addition refer the general
specification booklet page no66 item no 10.100 B and other relevant item for workmanship only .please refer all
these page for workmanship only not for the mode of measurement and payment .
Mode of Measurement & payment
The measurement will be in terms of kilogram and payment will be made per unit rate of kilogram of the complete
item including minor civil work for fixing the Ms grill .The rate includes fixing of the M S Grill at any floor level up to
any height and at window opening, on wall or column faces, duct covering. The sample piece of one grill panel shall
be got prepared and get it approved from architect. Work shall be carried out as per approved sample. As this is
fabrication work, necessary samples of various types of mild steel bright bar, hollow pipe various mild steel section
and support members shall be approved .No payment shall be made for any wastage of material or labor work
required to complete the item in all aspect up to all height , level and lead .
Providing and fixing 18 mm thick approved quality Marble stone mirror polished, machine cut counter for Vanity
counter , wash basin with support and stability which include zeri cutting refitting , plastering making good of
surfaces , vanity counters fascias patti of Marble stone with molding, cut out for wash basin sink required sizes of
approved shade, texture and color laid in zeri in line level and plumb with cutting out v section claning out wetting
grouting with cement slurry 1: 3( 1 cement : 3 Coarse sand ) with joints treated with white cement mixed with
matching pigment , epoxy touch ups incl. rubbing, Mirror polishing curing etc. complete at all levels as per
instruction of Architect or engineer in charge.
Approved quality 18 mm thick approved quality Green Marble stone , white cement , matching pigment , sand
cement , great , kapachi 7 other material required for the item.
Contractor have to provide the approved quality , as per approve sample 18 mm thick mirror polished , machine
cut for Green Marble stone for, vanity counters facias and similar location of required size of approved shade
color and texture . the marble should be laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand )
and with joints treated with white cement , mixed with matching pigment , epoxy touch ups . contractor have to
provide kota stone as structural member for , support ,sandwich platform wherever it required or instruction of
engineer in charge contractor have to do necessary polishing , rubbing and mirror polishing of the each marble
stone , including rubbing , curing etc complete at all levels. Contractor has to provide fascia Patti with necessary
molding and polishing as per the instruction of architect. black granite for fixing marble / granite stone over and
above corresponding basic item in facia and drops of width up to 150 mm with epoxy resin based ( araldite or
equivalent ) adhesive including cleaning etc complete contractor has to provide opening of required size and shape
for wash basins , kitchen sink in kitchen platform , vanity counters and similar location in marble / black granite
stone work including necessary holes for pillar taps etc including rubbing and polishing of cut edges . contractor has
to provide edge molding to 18 mm thick marble stone counters , vanities etc which including machine polished to
edge high gloss finish etc complete as per design approved by engineer-in charge.
Mode of measurement & payment
The work done shall be measured in Sqmt for visible area of work done. The length and width of the marble
platform will be measured and the hole for wash basin facia patty and molding for the facia patty are not paid
separately. The rate will be of complete item of creating a black granite platform/ counter for wash basin in all
aspect. The rate shall be for a unit of one sq. meter. The sample of marble shall be get approved from architect
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as per approved design Confirming to IS 15658 :
including 35 mm Sand layer for levelling and filling the joint with sand in proper line and level as per guidlines of IRC
: SP 63-2018 etc. Complete
The interlocking pavers of approved color and shape and made out with IS quality Portland cement, fine quality
sand and aggregates of 4.5 mm and smaller size. The pavers should be reflective with uv stabilized color anti glare
and anti skid groove .All the ingredient of pavers should meet the relevant IS codes. The sand used for the pavers
should be finer than the sand used for bedding. Contractor have to produce necessary testing certificate as per is or
The entire work to be carried out as per the approved color combination , shape and drawings , design and in the
pattern as given by architect. The workmanship is required to be of excellent quality and the pavers blocks should
be manufactured in automatic plants using weigh batching and hydraulic compaction. The mould for manufacturing
the pavers should be of hard steel and should be manufactured in single layer only. The vertical surfaces should be
perpendicular to the base and this also should be retained when kept for drying. The chamfers are to be of uniform
quality. The pavers should have uniform interlocking space of 2 to 3 mm for proper compacted sand filling after the
vibration on the paver’s surface. The pavers should have the following Eng. Properties when tested as per IS2185.
Crushing strength 250 kg per cm2 or as per architect’s requirement.
Maximum up to 450 kg cm2 Water absorption 7 % max. The pavers have to be steam cured to attain min 90 % of
crushing strength after one week of manufacturing. However, the pavers should be able to possess intermediate
crushing strength of 250 kg per cm2 or as per architect’s requirement. Maximum up to 450 kg cm2 before laying.
The pavers are to be laid as per the slope by the experienced workman by using compaction of sand by vibration.
The pavers used at the edge of curbing should be cut by hydraulic splitting keeping verticality intact.
The contractors should prepare the base by minimum 75mm thick sand bed to attain after compaction. The sand
should not be compacted and only after the pavers are laid the compaction by vibration should be done. The
jointing sand should be deposited all over the pavers to obtain suitable uniform joints.
Payment and Mode of measurement
The complete finished job will be measured and the unit of measurement will be in square meters. The payment
should be made as per square meter of paving as per detail design and colour combination of the paving blocks.
The rate includes the supplying and filling of 75 mm thick sand layer with leveling of the sand below the paving
block The contractor have to produce necessary testing certificate from manufacturer and govt. Approved
laboratory, both for third party inspection without any extra cost.
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height
and 15cm thick of M250 grade concrete as per approved design and including excavation for fixing in proper line
and level, filling the joint with C:M 1:3 (1cement:3fine sand) etc complete.
1.1. Pre cast concrete kerb stone of gray cement based concrete block 30 cm length 30 cm height and 15 cm thick
of M 250 Water shall conform to M-1. Cement shall conform to M-3. Sand shall conform to M-6. Grit shall conform
to M-8 Course aggregate shall conform M-12. Necessary foam work , tools tackles ,plant and machinery to cast and
fix the cubing block at specific location
2.0 workmanship
The complete concrete work shall give the appearance of uniformity in surface contour and texture, and shall be
accurately constructed to line and grade. The required joints shall show neat Edge and surface alignment on
curved construction shall conform closely to the planned curvature, and the flow-line surface of gutters shall be
finished as necessary to eliminate low spots and avoid entrapment of water.
Concrete edges and surfaces designed to straight line or grades will be checked with a 3 meter straightedge, and
any deviations in excess of 5 mm will be considered unacceptable work. Unacceptable work shall be removed and
be replaced with acceptable work as ordered by the engineer in charge.
2.1. The relevant specification of item No. 5.4.1.of building specification booklet of ordinary concrete shall be
followed except that the concrete mix shall be designed form preliminary tests. The proportioning of cement and
aggregates shall be done by weight and necessary precautions shall be taken in the production to ensure that the
required work cube strength is attained and maintained. The controlled concrete shall be in grades of, M-200, with
prefix controlled added to it. The letter M refers to mix and the numbers specify 28 days works cube compressive
strength of 150 mm. Cubes of the mix expressed in Kg./Cmt.
2.2. The proportion of cement, sand and coarse aggregate shall be determined of weight. The weight batch
machine shall be used for maintaining proper control over the proportion of aggregates as per mix design. The
strength requirements of different grades of concrete shall be as under:
Grade Compressive strength of 15 cms. Cubes in Kg./Cmt. At 28 days, Work test Min.
Concrete conducted in accordance with I.S. 516-1959. Preliminary test Min.
In all cases, the 28 days compressive strength specified in above be the criteria for acceptance or rejection of the
concrete. Where the strength of a concrete mix as indicated by tests, lies in between the strength of any two
grades specified in the above table, such concrete shall be classified in for purpose as concrete belonging to the
lower of the grades between which its strength lies.
3.0. Workmanship
3.1. The proportions for ingredients chosen shall be such that concrete has adequate workability for conditions
prevailing on the work question and can be property compacted with means available except where ft can be
shown to the satisfaction of the Engineer-in-charge, that supply of properly graded aggregate of uniform quality
can be maintained till the completion of work, grading of aggregate shall be controlled by obtaining the coarse
aggregates in different sizes and bending them in the right proportions as required. Aggregates of different sizes
shall be stocked in separate stock piles. The required quantity of material shall be stock piled several hours,
preferably a day
Before use. The grading of coarse and fine aggregate shall be checked as frequently as possible, the frequency for a
given job being determined by Engineer-in-charge to ensure that the suppliers are maintaining the uniform grading
as approved for samples used in the preliminary tests..
3.2. In proportioning concrete, the quantity of both cement and aggregate shall be determined by weight. Where
the weight of cement is determined by accepting the maker's weight per bag, a reasonable number of bags shall be
weighted separately to check the net weight. Where cement is weighted form bulk stocks at site and not by bags, it
shall be weighed separately from the aggregate. Water, shall either be measured by volume in calibrated tanks or
weighed. All measuring equipment shall be maintained in clean, and serviceable condition. Their accuracy shall be
periodically checked.
3.3. It is most important to keep the specified water cement ratio constant and at its correct value. To this end,
moisture content in both fine and coarse aggregates shall be determined by the Engineer-in-charge according to
the weather conditions. The amount of mixing water shall then be adjusted to compensate for variations in the
moisture content. For the determination of moisture content in the aggregates. I.S. 2386 (Part-Ill) shall be referred
to. Suitable adjustments shah also be made in the weights of aggregates due to variation in their moisture content.
Minimum quantity of cement to be used in controlled concrete shall not be less than 220 kg./M-3 in plain concrete
and not less Than 250 kg/M-3 in reinforced concrete.
4.0. Mode of measurement & payment
4.1. The consolidated cubical contents of concrete work for pre cast curbing as specified in item shall be measured
in running meter . The rate includes cost of all materials labour, tools and plant required for mixing, foam work
curbing block in position , line level and alignment , vibrating and compacting, finishing, as directed, curing and all
other incidental expenses for producing centre of specified strength. The rate excludes the cost of form work. The
rate shall be for a unit of one running meter for complete item of curbing fixing at the specific location
Providing and fixing of CIRCULAR counter type wash basin having size of 470 x 470 x 200 mm counter type with CI
/ MS/SS clamps or fastener as per approved sample .The counter type wash basin in should be of ivory colour . The
Item shall be including painting of fittings and brackets, cutting and making good the walls and floors wherever
required including mior civil and painting works & fitting up to all floor with all lead & lift as per detail specification
, approved sample and as per instruction of Architect & engineer in charge.
Approved quality CIRCULAR counter type wash basin having size of 470 x 470 x 200 mm of ivory or other
approved color with CI / MS/SS clamps or fastener , on the counter top marble platform , counter top Wash Basin
405 x325 x 145 mm or same size ,west , west coupling , west pvc flexible pipe other fittings and brackets
The contractor has to providing and fixing Calvin wall mounted type wash basin with CI / MS/SS clamps or fastener
, on the counter top marble platform , c CIRCULAR counter type wash basin having size of 470 x 470 x 200 mm or
same size including painting of fittings and brackets , cutting and making good the walls wherever required. in
ivory color or other approved color. which includes , 32 mm CP brass west ,west , west coupling , west pvc flexible
pipe other fittings and brackets , of standard pattern includes necessary , nipple, coupling , Teflon tape other
consumable and other plumbing material . The scope of work includes necessary, plumbing, cutting, threading and
fixing of bib cock and minor required civil work to complete the item in all respect. Refer general technical
specification booklet page no 148 item no 23.127 for workmanship as per Instruction of engineer in charge.
Mode of measurement & payment
The mode of measurement payment shall be in unit of each number. The rate includes cost of all labor material,
tools and plant etc required for satisfactory completion of this item.
Providing and fixing of pillar tap 1/2” with capstan head. screw down high pressure with screws, shanks and back
nuts.(A) 15 mm dia. as approved by engg. in charge with necessary hex nipple fitting, Teflon tap and other
consumable and labor etc complete up to ALL floor level with all lead and lift including minor civil and painting
works & fitting up to all floor with all lead & lift as per detail specification , approved sample and as per instruction
of Architect & engineer in charge
Providing and fixing jaquar collection only chromium plated pillar tap Florentine FLR-5021M , kubix, aria series
Use Brass Ingots only in raw material for casting purposes as per international standards which gives perfect
surface finish. Before casting internal cores are made on core shooter machines. The raw material gives perfect
surface finish. The raw material for these is resin-coated sand. Since cores are made on machines and not manually,
this ensures uniform wall thickness enabling smooth water passage inside the fitting.
The Internal fitting consists of the following parts: -
Bonnet, this made by forgoing which gives extra strength.
Spindle: This is made on automatic precision machines with extruded brass rod as per standard BS249 which
provides uniformity and are fully replaceable.
The Acme threads on the spindles have more strength and are long lasting as they are machined with precision
PMT (Traub Automatic) machines on extruded brass rods.
Rubber ‘O’ Ring closes the water entry from lower chamber to the internal fitting, this keeps the threads always
lubricated and hence result in very low wear and tear and lasts longer.
The bore of the seat and the water passage area throughout the body section have a uniform diameter of 12.7 mm
resulting in better flow of water even on normal water pressure
All internal fittings are made from extruded brass rods on PMT automate (Traub Machines). The Automats being
precision machines make the working parts standardized and hence easily replaceable. And also used imported
burnishing tools to have mirror finish in our WALL MIXER NON-TELEPHONIC to give long life to rubber parts thus
reducing its wear and tear. Polishing / Grading are done on the automatic machines to provide mirror smooth finish
which is essential for perfect surface coating.
a) NICKEL PLATING
Latest ultrasonic cleaning system is used for cleaning and degreasing the product before electroplating. The
thickness of nickel is 12 to 14 Microns as per international standards.
b) CHROMIUM PLATING
Quality chromium plating system which is copper based is used for giving the best surface shine having very high
resistance against corrosion. Chrome thickness is 0.4 Microns.
3. Final Product Testing
Testing is done at every stage of manufacturing process. After assembly all fittings are tested under 300 psi water
pressure as recommended by ISI standards. All concealed fitting have neumatic (air) testing.
Packing is done in colorful packing in bubble sheets to avoid any surface damage in transit of during storage.
All products have a warranty of 7 Years against any manufacturing defect covering for all kinds of finishes.
The contractor has to provide fixing of Pillar tap FLR-5021M with wall flange cock Jaquar make collection
Concealed Stop Cock with wall flange with necessary hex nipple fitting, Teflon tap and other consumable and labor
etc complete 15 mm dia, The item pertains to providing and fixing Pillar tap FLR-5021M of heavy duty CP brass, of
the specified diameter including necessary accessories. The Pillar tap FLR-5021M shall be fixed into the pipe line
with necessary sockets or union nut in places indicated on the drawing or as directed. Sun and safeda Teflon tape
shall be used for complete watertight joint. If leakages observed on test, the joint shall be remade to make it leak
proof. The item includes providing & fixing the Pillar tap FLR-5021M of the specified diameter on desired location
in centerline pattern on the tiles of wall or floors, with hex nipple, union, coupling & other consumable required to
fix the item completely, the dori, safeda, all necessary materials, plumbing labor and use of tools and minor civil
work required to complete the item up to satisfaction of engineer in charge.
Mode of Measurement and Payment:
The mode of measurement payment shall be in unit of each number. The rate includes cost of all labor material,
tools and plant etc required for satisfactory completion of the complete item in all aspect up to satisfaction of
engineer in charge. The rate shall be for a unit of one Number.
providing and fixing of Angular stop cock with wall flange with necessary hex nipple fitting, Teflon tap and other
consumable and labor etc complete 15 mm dia approved by engineer in charge with necessary coupling of
approved quality for wash basin. including fixing in pipe line etc complete up to sixth floor level with all lead and
lift including minor civil and painting works & fitting up to all floor with all lead & lift as per detail specification
approved sample and as per instruction of Architect & engineer in charge
Angular stop cock with capstan head screw down high pressure with screws, shanks and back nuts.(A) 15 mm dia
with hex nipple , union ,coupling & other consumable required to fix the item completely , the dori , safeda, all
necessary materials, plumbing labor and use of tools and minor civil work
Use Brass Ingots only in raw material for casting purposes as per international standards which gives perfect
surface finish. Before casting internal cores are made on core shooter machines. The raw material gives perfect
surface finish. The raw material for these is resin-coated sand. Since cores are made on machines and not manually,
this ensures uniform wall thickness enabling smooth water passage inside the fitting.
The Internal fitting consists of the following parts: -
Bonnet, this made by forgoing which gives extra strength.
Spindle: This is made on automatic precision machines with extruded brass rod as per standard BS249 which
provides uniformity and are fully replaceable.
The Acme threads on the spindles have more strength and are long lasting as they are machined with precision
PMT (Traub Automatic) machines on extruded brass rods.
Rubber ‘O’ Ring closes the water entry from lower chamber to the internal fitting, this keeps the threads always
lubricated and hence result in very low wear and tear and lasts longer.
The bore of the seat and the water passage area throughout the body section have a uniform diameter of 12.7 mm
resulting in better flow of water even on normal water pressure
All internal fittings are made from extruded brass rods on PMT automate (Traub Machines). The Automats being
precision machines make the working parts standardized and hence easily replaceable. And also used imported
burnishing tools to have mirror finish in our wall mixer non telephonic to give long life to rubber parts thus reducing
its wear and tear. Polishing / Grading are done on the automatic machines to provide mirror smooth finish which is
essential for perfect surface coating.
ii. Nickel plating
Latest ultrasonic cleaning system is used for cleaning and degreasing the product before electroplating. The
thickness of nickel is 12 to 14 Microns as per international standards.
iii. Chromium plating
Quality chromium plating system which is copper based is used for giving the best surface shine having very high
resistance against corrosion. Chrome thickness is 0.4 Microns.
iv. Final Product Testing
Testing is done at every stage of manufacturing process. After assembly all fittings are tested under 300 psi water
pressure as recommended by ISI standards. All concealed fitting have pneumatic (air) testing.
Packing is done in colorful packing in bubble sheets to avoid any surface damage in transit of during storage.
All products have a warranty of 7 Years against any manufacturing defect covering for all kinds of finishes.
The contractor has to provide fixing of Angular stop brass nuts with necessary hex nipple fitting, Teflon tap and
other consumable and labor etc complete 15 mm dia , The item pertains to providing and fixing of heavy duty CP
brass, of the specified diameter including necessary accessories. Angular stop cock brass nuts basin shall be fixed
into the pipe line with necessary sockets or union nut in places indicated on the drawing or as directed. Sun and
safeda Teflon tape shall be used for complete watertight joint. If leakages observed on test, the joint shall be
remade to make it leak proof. The item includes providing & fixing the Angular stop cock FLR - 5053N with brass
nuts basin of the specified diameter on desired location in centerline pattern on the tiles of wall or floors , with
hex nipple , union ,coupling & other consumable required to fix the item completely , the dori , safeda, all
necessary materials, plumbing labor and use of tools and minor civil work required to complete the item up to
satisfaction of engineer in charge.
Mode of Measurement and Payment:
The mode of measurement payment shall be in unit of each number. The rate includes cost of all labor material,
tools and plant etc required for satisfactory completion of the complete item in all aspect up to satisfaction of
engineer in charge. The rate shall be for a unit of one Number.
Providing and fixing wire braded PVC Connection flexible pipe of approved brand with brass union on both ends
with ferule type connector 45 cm long and 15 mm nominal bore un plasticized wire braded PVC Connection pipe
for angle cock (in let) of following size. (A) 15 mm dia etc complete up to all floor level with all lead and lift
including minor civil and painting works & fitting up to all floor with all lead & lift as per detail specification
approved sample and as per instruction of Architect & engineer in charge
Easy Flex Tube in Chrome Finish 1.5m Long with Nuts for washbasin with screws, shanks and back nuts
The contractor has to provide fixing of Easy Flex Tube in Chrome Finish 1.5m Long with Nuts for washbasin with
screws, shanks and back nuts with wall flange with necessary hex nipple fitting, Teflon tap and other consumable
and labor etc complete 15 mm dia, The item pertains to providing and fixing Easy Flex Tube in Chrome Finish 1.5m
Long with Nuts heavy duty CP brass, of the specified diameter including necessary accessories. The Easy Flex Tube
in Chrome Finish 1.5m Long with Nuts shall be fixed into the pipe line with necessary sockets or union nut in places
indicated on the drawing or as directed. Sun and safeda Teflon tape shall be used for complete watertight joint. If
leakages observed on test, the joint shall be remade to make it leak proof. The item includes providing & fixing the
Easy Flex Tube in Chrome Finish 1.5m Long with Nuts of the specified diameter on desired location in centerline
pattern on the tiles of wall or floors, with hex nipple, union, coupling & other consumable required to fix the item
completely, the dori, safeda, all necessary materials, plumbing labor and use of tools and minor civil work required
to complete the item up to satisfaction of engineer in charge.
All products have a warranty of 7 Years against any manufacturing defect covering for all kinds of finishes.
Mode of Measurement and Payment:
The mode of measurement payment shall be in unit of each number. The rate includes cost of all labor material,
tools and plant etc required for satisfactory completion of the complete item in all aspect up to satisfaction of
engineer in charge. The rate shall be for a unit of one Number
Providing and fixing of C.P. brass Towel Ring Square with rubit clean with screws, hardware as approved by
client .The item includes fixing on wall/tiles with necessary screw , fitting, Teflon tap , other consumable and
labour with minor civil work etc complete up to sixth floor level with all lead and lift etc. complete, including mior
civil and painting works & fitting up to all floor with all lead & lift as per detail specification , approved sample and
as per instruction of Architect & engineer in charge
Providing and fixing of Jaquar collection only C.P. brass Towel Ring Square AKB-35721& C.P. brass ACN-1121N
Towel Ring Square
The contractor has to provide fixing of jaquar collection C.P. brass Towel Ring Square with necessary hex nipple
fitting, Teflon tap and other consumable and labor etc complete 15 mm dia , The item pertains to providing and
fixing C.P. brass Towel Ring Square of heavy duty CP brass, of the specified diameter including necessary
accessories. The C.P. brass Towel Ring Square shall be fixed into the pipe line with necessary sockets or union nut in
places indicated on the drawing or as directed. Sun and safeda Teflon tape shall be used for complete watertight
joint. If leakages observed on test, the joint shall be remade to make it leak proof. The item includes providing &
fixing the Towel Ring Square of the specified diameter on desired location in centerline pattern on the tiles of wall
or floors, with hex nipple , union ,coupling & other consumable required to fix the item completely, the dori,
safeda, all necessary materials, plumbing labour and use of tools and minor civil work required to complete the
item up to satisfaction of engineer in charge.
Mode of Measurement and Payment :
The mode of measurement payment shall be in unit of each number. The rate includes cost of all labour material
tools and plant minor plumbing work etc required for satisfactory completion of the complete item in all aspect up
to satisfaction of engineer in charge. The rate shall be for a unit of one Number
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali of the following nominal
diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making
good the walls.
1.1. The PVC SWR Nahni Trap IS 14735 for drain with jali shall conform to M-69. The C.I. hinged or screwed
down cover shall be of best quality and approved by Engineer in charge.
2.0. Workmanship
2.1. The PVC SWR Nahni Trap with 100 mm. dia inlet and 50 mm. dia. outlet shall be fixed as per drawing or as
2.2. The PVC SWR Nahni Trap shall be jointed with C.I. pipe, 100 mm. dia. with lead joints. The lead joints shall
be done in conformation with I.S. 782-1976.
3.0. Mode of measurements and payment
3.1. The rate includes cost of all labor, materials, tools and plants etc. required for satisfactory completion of
this item including lead, jointing and testing.
3.2. The rate shall before a unit of one number.
Providing and fixing conceled center point to wall celling and floor CPVC PIPE (SDR -13.5) pipe having NSFseal for
portable water of following dia nominal bore ,tube ,fittings, and clamp including making good the wall, ceiling and
floor. (A) 15 mm dia.
Providing and fixing concealed center point to wall ceiling and floor CPVC PIPE (SDR -13.5) pipe having NSF seal for
portable water of following dia nominal bore ,tube ,fittings, and clamp including making good the wall, ceiling and
floor. (c) 25 mm dia.
Providing and fixing concealed center point to wall ceiling and floor CPVC PIPE (SDR -13.5) pipe having NSF seal for
portable water of following dia nominal bore ,tube ,fittings, and clamp including making good the wall, ceiling and
floor (E) 40 mm dia.
Providing and fixing concealed center point to wall ceiling and floor CPVC PIPE (SDR -13.5) pipe having NSF seal for
portable water of following dia nominal bore ,tube ,fittings, and clamp including making good the wall, ceiling and
floor (F) 50 mm dia.
Materials ( CPVC Pipe )
CPVC pipe suitable for hot water of various diameter , other connector for joint , assembly , ,bend , tee , reducer
branch connector , union , elbow and connector for bib cock , and other bathroom fitting and accessories , Teflon
tap , heat resistance pipe covering material , threads .
1.all Basic Materials Description- Chlorinated poly(viayl chloride)plastics used to make pipe ,tubing ,and fittings
meeting the requirements of this specification are categorized by two criteria. Namely. Basic short term
properties, and long-term hydrostatic strength sections 1.1 and 1.2 respectively define these categories.
1.1,Basic Short term properties-This specification covers CPVC 41 pipe. Tubing and fittings made from plastic
materials meeting the mechanical strength, hear resistance, flammability, and chemical resistance
requirements for CPVC 23447-B in specification D
Note –CPVC 23447-B was designated as CPVC type IV Grade 1, and is be rein designated as CPVC 41. This is
also used in making pipe tubing or fittings.
1.2, Long-Term Hydrostatic Strength- This specification covers CPVC 41 pipe, tubing and fittings which are
further defined by hydrostatic design stress as CPVC 4120, pipe and tubing are so defined on the basic of
long term hydrostatic strength tests and are made from compounds having an established 180’ F ( 82 C)
hydrostatic design stress of 500 psi [3.45 MPa] or greater in accordance with appendix XI AND test method
D2837, fittings are so defined by hydrostatic sustained pressure tests on fitting assemblies , required by this
specification . based on the hydrostatic strength of the corresponding pipe or tubing . Note- no hydrostatic
design stress as such existing for fittings until such time as long term hydrostatic strength test method for
fittings are developed.
Workmanship, Finish and Appearance
1,The pipe shall be homogeneous throughout and essentially uniform in color, density and other properties.
The inside and outside surfaces shall be semi matte or glossy in appearance ( depending on the type of CPVC
plastic) and free of chalking, sticky or tacky material. The surfaces shall be free of excessive bloom, that is
slight bloom is acceptable. The pipe wall shall be free of cracks, holes, blisters, voids, foreign inclusion or other
defects which are visible to the naked eye and and which may affect the wall integrity , Holes deliberately
placed in perforated pipe are acceptable . Bloom or chalking may develop in pipe exposed to direct ray of
the sun ( ultraviolet radiant energy) for extended periods and consequently these requirements do not
apply to pipe after extended to direct rays of the sun. the contractor has to fit and assembled necessary
fitting to pipe with all kind of connector , brass or other metal fuel and joining material. the contractor has to make
necessary zeri cutting and make finish the surface after piping erection in bathroom and other wall with suitable
cement plaster , or tiles surface at his own cost. The hot water pipe should be cover with heat resistance material
covering without any extra cost. The contractor has to give hydraulic test of entire pipe assembly and pipe line with
minimum7 kg pressure in the line at is own cost. The 50% amount of the total amount of particular item bill shall
minimum7 kg pressure in the line at is own cost. The 50% amount of the total amount of particular item bill shall
be withheld with GHB up to the satisfactory result of hydraulic test for entire C PVC piping assembly .
Mode of Measurement & payment
The complete finished job shall be measured in the unit of running meters. The payment should be made per
running meters including all material, tools, tackle, labour, adhesive, hardware, machinery, minor civil work etc
required to complete the job in all and every aspect .the contractor ahs to give hydraulic test of the entire piping
assembly then only payment shall be made for the item. no extra payment shall be done for fixing at any floor with
all lead and lift , rate include transportation , scaffolding etc
providing & fixing to wall ceiling and floor 10 kg/f/cum working pressure polyethylene pipes of the following
outside diameter ,low density complete with special flange compression type fittings ,wall clamped making good
wall ,cling and floor - 75 mm dia
providing & fixing to wall ceiling and floor 10 kg/f/cum working pressure polyethylene pipes of the following
outside diameter ,low density complete with special flange compression type fittings ,wall clamped making good
wall ,cling and floor - 110 mm dia
1.1. The low density polythene pipe of specified diameter with 10 Kg/Sq. Cm, working pressure shall conform to I.S.
3076-1968. The specials and fittings required shall be of best quality.
2.0. Workmanship
2.1. The P.V.C. pipes of specified diameter shall be fixed as directed. Due to thermal expansion of rigid ' P.V.D.
pipes, due allowance shall be made particularly in over ground pipe lines for any change in length of pipe line which
may occur during installation or when pipe line which may occur during installation or when pipe line is in service.
2.2. Above ground installation of rigid P.V.C. pipe should be under taken after preparations are observed for their
protection against direct sun rays and mechanical damage.
2.3. The rigid P.V.C. pipe lines should not be kept exposed above ground when it passes through public places,
railway lines, road side and foot paths.
2.4. P.V.C. pipes shall be supported at the following intervals:
-100 mm. dia 1500 mm. -75 mm. dia 1200.mm. -150 mm. dia.2000 mm.
2.5. Closer support spacing shall be provided if recommended by the manufacture.
2.6. The guide lines indicated by the manufacturer regarding handling, transportation, storing, laying and jointing pf
pipes shall be kept in view during execution.
2.7. P.V.C. pipes shall be fixed on wall with wooden plugs and suitable plastic clamps.
2.8. Jointing the pipes :
2.8.1. The pipes and sockets shall be accurately cut. The ends of the pipes and fittings should be absolutely free
from dirt and dust. The outside surface of the pipes and the inside of the fittings shall then be roughened with
emery paper, and then solvent cement joint. Since solvent cement is aggressive to P V.C. care must be taken to
avoid applying excessive cement to the inside of pipe sockets as any surplus cement cannot be wiped of after
jointing. Empty solvent cement tins, brushes, rags, or paper impregnated with cement should not be buried in the
trenches. They should be gathered not left scattered about, as-they can prove to be a hazard to animals, which may
2.8.2. If any manufacturer recommends its own methods of jointing the same shall be adopted after necessary
Approval from the Engineer-in-charge.
2.9. Laying pipes in Trenches:
2.9.1. The pipes shall be laid over uniform relatively soft fine trained soil found to be free of presence of hard
object such as large flints, rocky projections, large tree roots etc. The width of the trenches shall be minimum width
required for working.
2.9.2. The pipes laid underground shall not be less than one meter from the ground level. The pipe shall be
positioned in the trenches so as to avoid any induced stressed due to deflection. Any deviation required shall be
obtained by using proper type of rubber ring joints.
3.0. Mode of measurements & payment
3.1. The relevant specifications of item 23.2. (A) Shall be followed except that the P.V.C. pipes of specified dia. shall
be paid under this item. 3.2. The unit rate shall be for a unit of one running meter for 10.0 kg/sqm working pressure
polyethylene pipes The complete finished job shall be measured in the unit of running meters. The payment should
be made per running meters including all material , tools , tackle , labour , adhesive , hardware , machinery , minor
civil work etc required to complete the job in all and every aspect .the contractor has to give hydraulic test of the
entire piping assembly then only payment shall be made for the item. No extra payment shall be done for fixing at
any floor with all lead and lift rate include transportation, scaffolding etc
BILL OF QUANTITIES
BILLOFQUANTITIES
1. The bill of Quantities shall be read in conjunction with the Instructions to
Bidder,ConditionsofContract,TechnicalSpecificationsandDrawings.
2. The quantities given in the Bill of Quantities are estimated and provisional,
andare given to provide a common basis for bidding. The basis of payment will be
theactual quantities of work ordered and carried out, as measured by the
Contractorand verified by the Engineer and valued at the rates and prices
tendered in thepriced Bill of Quantities, where applicable, and otherwise at such
rates and pricesasthe Engineermayfixwithin the termsofthe Contract.
3. TheratesandpricestenderedinthepricedBillofQuantitiesshall,exceptinsofarasitisot
herwiseprovidedundertheContract,includeallconstructionalplant,layout,supervisi
on,materials,erection,maintenance,insurance,profit,taxes and duties, together
with all general risks, liabilities and obligations set outorimpliedin the Contract.
4. TheratesandpricesshallbequotedentirelyinIndianCurrency.
5. A rate or prices shall be entered against each item in the Bill Quantities,
whetherquantities are stated or not. The cost of Items against which Contractor
has failedto enter a rate or price shall be deemed to be covered by other rates and
pricesenteredin theBillofQuantities(in case ofItemrate contract).
6. The whole cost of complying with the provisions of the Contract shall be
includedin the items provided in the priced Bill of Quantities, and where no Items
areprovided the cost shall be deemed to be distributed among the rates and
pricesenteredforthe relateditems ofWork.
7. Generaldirectionand descriptionsofwork and materialsarenot
necessarilyrepeatedorsummarizedintheBillofQuantities.Referencestotherelevant
sections of the contract documentation shall be made before entering rates
orpricesagainst eachiteminthe BillofQuantities.
8. Themethodofcompletedworkofpaymentshallbeinaccordancewiththespecification
for Road and Bridge works. For building works specifications forbuildingare tobe
9. ErrorswillbecorrectedbytheEmployerforanyarithmeticerrorspursuantto
Clause29oftheInstructionstoBidder.
10. Rock is defined as all materials which, in the opinion of the Engineer,
requiredblasting,ortheuseofmetalwedgesandsledgehammers,ortheuseofcompres
sed air drilling for its removal, and which cannot be extracted by
rippingwithatractorofatleast150kw with asinglerearmounted heavy duty ripper.
BILLOFQUANTITIES
(A) Percentage Rate Tender UptoINR50Cr.)
SCHEDULE-B: SECTION-A (CIVIL WORK)
Kamdhenu University
Name of work :Construction of VCC department for Veterinary science collage at kamdhenu university Navsari
Architect : Earth Foundation
Sr. Estimated Description of Item Rate Unit Amount
No. Quantities Rate in Rate in
but may be figure words
1 2198.74 Excavation for foundation upto 1.5 m 120.01 Rupees One Cmt
depth including sorting out and stacking Hundred
of useful materials and disposing off the Twenty And
excavated stuff upto 50 Meter lead.(A) Paise One
Loose and soft soil Only
2 1291.5 Excavation for foundation for depth 166.35 Rupees One Cmt
from 1.5 m to 3.0 m including sorting Hundred
out and stacking of useful materials and Sixty Six And
disposing off the excavated stuff upto Paise Thirty
50 Meter lead.(B) Dense or Hard soil Five Only
3 481.39 Providing and laying rubble for apron 1067.08 Rupees One Cmt
(each stone weighting not less than Thousand
40Kg.) including and packing and filing Sixty Seven
in the interstices with quarry-spalls. And Paise
4 322.96 Providing and laying cement concrete 3713.67 Rupees Cmt
1:2:4 (1- Cement : 2- Coarse sand : 4- Three
graded stone aggregates 20 mm Thousand
nominal size) and curing complete Seven
excluding cost of formwork in (A) Hundred
Foundation and Plinth Thirteen And
5 185.41 Providing and laying cement concrete 3080.90 Rupees Cmt
1:3:6 (1-Cement :3- coarse sand : 6- Three
hand broken stone aggregates 40 mm Thousand
nominal size) and curing complete Eighty And
excluding cost of formwork in (A) Paise Ninety
Foundation and Plinth Only
6 3160.42 Filling available excavated earth 133.65 Rupees One Cmt
(excluding rock) in trenches , plinth , Hundred
sides of foundations etc. in layers not Thirty Three
exceeding 20 cm in depth consolidating And Paise
each deposited layer by ramming and Sixty Five
7 100.95 Filling in foundation and plinth with 471.69 Rupees Four Cmt
sand under floor including watering Hundred
,ramming and consolidating and Seventy One
dressing etc complete as directed by And Paise
Engineer in charge Sixty Nine
8 292.76 Filling in foundation and plinth with 270.30 Rupees Two Cmt
murrum or selected soil in layers of Hundred
20cm. thickness including watering, Seventy And
ramming and consolidating etc. Paise Thirty
9 732.56 Providing & laying controlled cement 4557.12 Rupees Four Cmt
concrete M - 250 RCC work with curing Thousand
etc. complete including the cost of form Five Hundred
work but excluding the cost of Fifty Seven
reinforcement for R.C.C. Work in And Paise
foundation Twelve Only
10 84.21 Providing & laying controlled cement 7083.13 Rupees Cmt
concrete M - 250 RCC work with curing Seven
etc. complete including the cost of form Thousand
work but excluding the cost of Eighty Three
reinforcement for R.C.C. Work in And Paise
column up to pl. Thirteen
11 63.65 Providing & laying controlled cement 7767.91 Rupees Cmt
concrete M - 250 RCC work with curing Seven
etc. complete including the cost of form Thousand
work but excluding the cost of Seven
reinforcement for R.C.C. Work in Hundred
column up to all floor with any lead and Sixty Seven
12 174.75 Providing and laying controlled cement 5921.63 Rupees Five Cmt
concrete M:250 RCC and curing Thousand
complete including the cost of form Nine
work but excluding the reinforcement Hundred
for reinforced concrete work in tie Twenty One
beam , ground beam as directed by And Paise
engineer incharge. Sixty Three
13 128.34 Brick work using common burnt clay 4153.07 Rupees Four Cmt
building bricks having crushing strength Thousand
not less than 35 kg./Sq.Cm. in One
foundation and plinth in Cement Mortar Hundred
1:5. (1- Cement : 5 -fine sand)(B) Fifty Three
Conventional And Paise
14 29.87 Providing and laying controlled cement 6289.27 Rupees Six Cmt
concrete M:200 RCC and curing Thousand
complete including the cost of form Two
work but excluding the reinforcement Hundred
for reinforced concrete work in Eighty Nine
coping/RCC bend as directed by And Paise
engineer incharge. Twenty
15 306.96 Masonary work using Aerated light 4597.84 Rupees Four Cmt
weight concrete block having crushing Thousand
strength not less than 35 kg/sqcm for Five Hundred
super structure above plinth level upto Ninety Seven
floor two level in cement mortar 1:5 ( 1 And Paise
cement : 5 fine sand ) complete as per Eighty Four
Technical Specification Only
16 81.18 Half brick masonry in common brunt 656.34 Rupees Six Smt
clay building bricks having crushing Hundred
strength not less than 35 kg/Sq.cm in Fifty Six And
cement mortar 1 : 4 ( 1 cement : 4 Paise Thirty
coarse sand ) in foundation and plinth. Four Only
extra for half brick masonry in super
structure above plinth level up to floor
two level. (B) conventional
17 37.87 Providing and laying controlled cement 6667.01 Rupees Six Cmt
concrete M:200 RCC and curing Thousand Six
complete including the cost of form Hundred
work but excluding the cost of Sixty Seven
reinforcement for reinforced concrete And Paise
work in Lintel/Sill RCC Bend up to all One Only
floors with all lead and lift as directed
by engineer incharge.
18 91.75 Providing and laying controlled cement 6327.65 Rupees Six Cmt
concrete M:200 RCC and curing Thousand
complete including the cost of form Three
work but excluding the reinforcement Hundred
for reinforced concrete work in Slab Twenty
level beam up to all level with all lead Seven And
and lift as directed by engineer in Paise Sixty
charge. Five Only
19 189.51 Providing and laying controlled cement 6429.66 Rupees Six Cmt
concrete M:200 RCC and curing Thousand
complete including the cost of form Four
work but excluding the reinforcement Hundred
for reinforced concrete work in Slab up Twenty Nine
to all level with all lead and lift as And Paise
directed by engineer in charge. Sixty Six Only
20 8.28 Providing and laying controlled cement 6664.99 Rupees Six Cmt
concrete M: 200 RCC and curing Thousand Six
complete including the cost of form Hundred
work but excluding the reinforcement Sixty Four
for reinforced concrete work in And Paise
projection /Whether shed Cantilevers Ninety Nine
up to floor two level with all lead and Only
lift as directed by engineer in charge.
21 4.9 Providing and laying controlled cement 7216.45 Rupees Cmt
concrete M: 200 RCC and curing Seven
complete including the cost of form Thousand
work but excluding the reinforcement Two
for reinforced concrete work in RCC Hundred
Staircase Cantilevers up to floor two Sixteen And
level with all lead and lift as directed Paise Forty
by engineer in charge. Five Only
22 141708.08 Providing TMT Bar FE 500/500D 77.29 Rupees Kg
reinforcement for R.C.C. work including Seventy
bending, binding and placing in position Seven And
complete upto floor two level. Paise Twenty
23 2631.61 Providing 15mm thick cement plaster in 176.09 Rupees One Smt
single coat on Rough (Similar)side of Hundred
single or half brick walls for interior Seventy Six
plastering upto floor two level and And Paise
finished even and smooth in (ii) Cement Nine Only
mortar 1:4 (1-cement :4-sand)
24 1318.51 Providing 10 mm thick mala cement 201.53 Rupees Two Smt
plaster in single coat on ceiling and Hundred
soffits of stairs for interior plastering up One And
to floor two level and finished even and Paise Fifty
smooth in (ii)Cement mortar 1:4 Three Only
(1cement :4 sand) mala plastering line
level and plumb to develop even
surface as per instruction of engineer
in charge etc complete.
25 391.24 Providing 20mm thick sand faced 339.15 Rupees Smt
plaster on walls upto height 10 meters Three
above ground level consisting of 12mm Hundred
thick backing coat of cm 1 :3 ( 1 cement Thirty Nine
: 3 sand )with other required Chemical And Paise
binding material and 8mm thick Fifteen Only
finishing coat of cm 1 : 1 ( 1 cement :
sand) etc complete.
26 413.88 Providing throating or plaster drip and 43.22 Rupees Forty Rmt
molding to R.C.C. Chhajja. Three And
27 3950.12 Applying two coats of Birla or Asian 40.59 Rupees Forty Smt
acrylic lippy (putty) and two coats of And Paise
primer of approved brand and Fifty Nine
manufacture on new wall surface to Only
give an even shade including thoroughly
brushing the surface free from mortar
dropping and other foreign matter and
sand prepared smooth.
28 2631.61 Wall Painting (three coats) with plastic 122.58 Rupees One Smt
emulation paint of approved brand and Hundred
manufacture on undecorated wall Twenty Two
surface to give an even shade including And Paise
thoroughly brushing the surface free Fifty Eight
from mortar droppings and other Only
foreign matter and sand papered
smooth extra every subsequent coat of
wall painting with plastic emulation
paint of approved brand.
29 1318.51 Ceilings painting (three coats) with 128.13 Rupees One Smt
plastic emulsion paint of approved Hundred
brand and manufacture on undecorated Twenty Eight
wall surface to give an even shade And Paise
including throughly brushing the surface Thirteen
free from mortar droppings and other Only
foreign matter and sand papered
smooth. painting with plastic emulsion
paint of approved brand on ceilings and
30 391.24 Finishing wall with weather proof 117.40 Rupees One Smt
exterior emulsion paint on wall surface Hundred
(two coats) to give an required shape Seventeen
even shade after thoroughly brushing And Paise
the surface to remove all dirt, and Forty Only
remains of loose powdered
materials.etc complete
31 576.29 Providing and laying polished Kota 1010.92 Rupees One Smt
stone slab flooring over 20mm Thousand
(Average) thick base of cement mortar Ten And
1:6 (1-cement : 6-coarse sand) or L.M. Paise Ninety
1.1.5 (1-Lime putty :1.5 - coarse sand) Two Only
laid over and jointed with grey cement
slurry mixed with pigment to match the
shade of slab including rubbing and
polishing etc. complete. (A)25mm thick
32 35.68 Providing and laying polished kota stone 1089.18 Rupees One Smt
slab 25mm thick in risers of steps, Thousand
skirting Dedo and pillars laid on 10mm Eighty Nine
thick cement mortar 1:3 (1-Cement : 3 And Paise
coarse sand) and jointed with gray Eighteen
cement slury mixed with pigment to Only
match the shade of slab including
rubbing and polishing etc. complete.
33 71.89 Providing and laying rough kota stone 1263.65 Rupees One Smt
flooring over 20mm (Average) thick Thousand
base of cement mortar 1:6 (1-cement : Two
6-coarse sand) or L.M. 1.1.5 (1-Lime Hundred
putty :1.5 - coarse sand) laid over and Sixty Three
jointed with grey cement slurry mixed And Paise
with pigment to match the shade of Sixty Five
slab including rubbing and polishing etc. Only
complete. (A)25mm thick
34 541.34 P & L 24" x 24" vitrified 8 mm thick tile 1432.78 Rupees One Smt
flooring over 20 mm (average) base of Thousand
cement mortar 1:6 ( 1 cement: 6 coarse Four
sand) on new surface or fixing on Hundred
existing flooring by adhesive material Thirty Two
including dismantling of existing And Paise
flooring and jointed with color cement Seventy
slurry including finised with flush Eight Only
pointing & cleaning the surface etc.
complete for antiskid Matt finish as per
approved sample
35 48.27 Providing and laying Vitrified tiles 8 to 1538.85 Rupees One Smt
10 mm thick , in skirting risers of steps Thousand
and dedo on 10mm thick cement Five Hundred
plaster 1:3 (1-cement : 3-coarse sand) Thirty Eight
and jointed with white cement slurry And Paise
36 18.22 Providing & laying Controlled cement 4408.65 Rupees Four Smt
concrete M 250 grade in Trimix flooring Thousand
/road for average 150 mm thick wearing Four
coat in RCC flooring without fly ash Hundred
with lead of 10 Km from plant site Eight And
including all other taxes octroi, Paise Sixty
transportation, pumping, pouring, Five Only
curing of concrete etc. complete
including cost of metallic C channel
from work but excluding the cost of
reinforcement in R.C.C. M 250 Trimix
flooring work having average 150 mm
thick wearing coat in RCC flooring laid
as detail design & directed. The item of
M 250 grade in Trimix flooring including
plant , machinery , tamping vibrating
finishing curing for 21 days , creating
expansion joint and filling in joints with
bitumen or other material as specified
etc complete with all lead and lift as
directed by engineer in charge .
(Minimum cement level as per IS 456-
2000 shall be adopted for concrete
grade) (C)Concrete Grade M-250
37 122 Dewatering and pattern making of TRI 60.60 Rupees Sixty Smt
MIX M-250 floor concrete by means of And Paise
vacuum dewatering using floater Sixty Only
machine and other necessary
equipment , plant and labour etc
complete as directed by engineer in
38 1563.38 Providing & lying CERAMIC tiles 6 to 8 997.88 Rupees Nine Smt
mm thick In skirting risers of steps and Hundred
dado on 10mm. Th. Cement plaster 1:3 Ninety Seven
(1 cement : 3 coarse sand ) pointing in And Paise
white cement and jointed with white Eighty Eight
cement slurry. The tiles should be Only
approved by engineer in charge and
architect , the color and pattern and
design as per instruction of architect
and as directed by engineer in charge
etc complete with first quality of tiles
only fixing up to all and any floor with
all lead & lift etc complete
39 217.61 Providing and fixing of minimum 16 1581.66 Rupees One Smt
mm thick Green marble stone slab for Thousand
jambs of doors and window .Green Five Hundred
marble stone should be spotless Eighty One
,without any crack , vain or other And Paise
damages joined with grey cement Sixty Six Only
slurry and matching pigment in vertical
and horizontal member , including
rubbing and polishing and full round
edge molding on both the sides( edge),
Mirror polishing curing of the Green
marble stone as per detail design and
instruction. The door frame should have
sandwich type Jambs stone fitting to
accommodate fixing of door where
required , the fixing of jambs with
necessary binding wire tiles piece,
adhesive , clamp , fastener, white
cement and matching pigment other
consumable, moulding and polishing
machinery other tools , tackles required
to complete the item. and where two
member vertical and horizontal meet it
should cut 45 degree angle etc up to
all floor with all lead & lift etc complete.
The Green marble stone size and quality
should be as per sample approved by
architect and Eng. in charge.
40 46.32 Providing and fixing of minimum 16/18 1628.60 Rupees One Smt
mm thick Rajasthan Black Granite stone Thousand Six
slab of approved quality for flooring , Hundred
riser of steps, tread dedo , landing in Twenty Eight
stair case over Bed of 20mm ( average) And Paise
thick base of cement mortar 1:6 Sixty Only
(1cement : 6 coarse sand) or lime
mortar 1:1.5 laid and jointed with white
cement slurry and matching pigment
including rubbing and polishing
complete for flooring in steps . The
fixing of Rajasthan Black Granite stone
slab 16/18 mm thick at the stair case
steps up to all floor in raiser & tread
including edge moulding to flooring
and two anti skid grooves as per
instruction of engineer in charge . The
fixing of Rajasthan Black Granite stone
slab as per detail design and instruction,
including necessary Mirror polishing
cutting of the stone , adhesive , clamp
fastener , other consumable and labour
and fixing up to all floor with all lead &
lift etc complete as directed by engineer
41 48.2 Providing and fixing minimum 50mm 90.90 Rupees Smt
wide sand blasting on Marble stone for Ninety And
stair case steps with necessary tools Paise Ninety
tacjels , equipment plant as per detail Only
design upto all floor with all lead & lift
etc complete as per instruction of
engineer in charge
42 2494.13 Applying general insecticide pest 51.52 Rupees Fifty Smt
control treatment to floors, cupboards One And
etc including labour material etc. Paise Fifty
complete. Using Heptachloride 20 EC. Two Only
As Per 6113_ pests Concentration
Weight 0.50 percent is recommended
one liter chemical emulsion dillute with
39 liter of water will give. Total dillute
concentration will be 40 liter inclusive
of one liter chemical emulsion
application 0.5 Liter chemical / Sqm of
surface is recommended as per I.S.
43 124.31 Providing and laying APP (Atactic 466.62 Rupees Four Smt
Polypropylene Polymer) modified Hundred
prefabricated five layer 3mm thick Sixty Six And
water proofing membrane, black Paise Sixty
finished reinforced with non-woven Two Only
polyester matt consisting of a coat of
bitumen primer for bitumen membrane
@0.40 ltr/sqm. by the same membrane
manufacture of density at 25 C, 0.87-
0.89 kg/ltr and viscocity 70-160 cps.
Over the primer coat the layer
membrane shall be laid using Butane
torch and sealing all joints etc., and
preparing the surface complete. The
vital physical and chemical parameters
of the membrane shall be as under :
Joints strength in logitudinal and
transverse direction at 23 C as
650/450N/5cm. Tear strength in
longitudinal and transverse direction as
300/250N/. Softening point of
membrane not less than 150 C. Cold
flexibility shall be upto -2 C when tested
in accordance with ASTM, M-5147. The
laying of membrane shall be got done
through the authorised applicator of
the manufacturer of membrane : (with
5 years service guarantee
44 39 Providing and laying cement concrete 370.13 Rupees Smt
flooring 1:2:4 (1-cement : 2-coarse sand Three
: 4-graded stone aggregate 20mm Hundred
nominal size) laid in one layer and Seventy And
finished with a floating coat of neat Paise
cement. (B) 50mm thick. Thirteen
45 124.31 Providing and laying broken China 765.97 Rupees Smt
Mosaic Flooring for terrace using 12 Seven
mm to 20 mm broken pieces of glazed Hundred
tiles to be laid over cement mortar 1:3 Sixty Five
to plain or slope and to be tempered to And Paise
bring mortar crème out up to surface Ninety Seven
using white cement including rounding Only
off junctions and extending them up to
15cm along the wall, clearing with
water and oxalic acidic. as directed. .
46 223.44 Providing cement vata (10cm. x 10 cm. 24.28 Rupees Rmt
size) quarter round in cement mortar Twenty Four
1:1 including neat cement finishing, And Paise
watering etc. complete. Twenty Eight
47 1000 Providing erecting and fixing double 3.95 Rupees Ltr.
coated Syntex PVC. (ISI) water tank of Three And
required capacity each with all Paise Ninety
necessary fittings and connection etc. Five Only
complete on terrace.
48 32.1 Providing and fixing to wall ceiling and 349.15 Rupees Rmt
floor 10.0 Kg. F/Cm2 working pressure Three
poluthene pipes of the following Hundred
outside Dia. Low densidy, complete Forty Nine
with special falnge compression type And Paise
fittings, wall clipsetc. including making Fifteen Only
good the wall ceiling and floor.(G)110
mm etc complete with propoer wall
clamping of Rain water pipe up to all
floor level with all lead and lift as per
instruction of engineer in charge
49 1633.72 Providing and fixing stainless steel 48.48 Rupees Forty Smt
chicken mesh jali at specific location Eight And
between R.C.C. and brick masonry Paise Forty
joints including fixing ,nailing while Eight Only
executing plastering on the various
surface at any height including all
labour & material to complete. chicken
mesh jali should be minimum 20 cm
only. the item as directed by engineer
incharge etc. Complete
50 166.5 Providing and fixing window having 1713.70 Rupees One Smt
extruded aluminum Colour anodized Thousand
section frame main outer size 63.50 Seven
x38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, Hundred
horizontal two track member size 61.85 Thirteen And
mm x 31.75 mm x 1.20mm @ wt.of Paise
0.695 Kg/mt, vertical member of size Seventy Only
wt.of 0.659 Kg/mt with sliding shutters
of horizontal member size 40mm x
vertical member of size40mm x 18mm x
0.457 Kg/mt with 5 mm thick
transparent bronze colour tinted float
glass with powder coated aluminum
fittings and fixtures and transparent
silicon sealant glass fixing to frame as
per details etc complete for window.
51 124.2 Providing and fixing alluminium 6306.44 Rupees Six Smt
Panelled single/double door Partly Thousand
Glazed & Partly with 12 mm thick both Three
side pre laminated Particle Board with Hundred Six
Frame having extruded alluminium And Paise
color anodized section frame main Forty Four
Frame size 101.60 mm x 44.45 mm x Only
3.18mm ( of Section No.20011 @ wt. of
2.54 kg/mt )unit providing shutters of
bottom & Top rail- 114.30 mm x
mm x 3.18mm (of Section No.19511 @
wt. of 2.65 kg/mt ) Shutter Middle rail =
150 mm x 44.45 x 2.65 mm (of Jindal
Section No.20002 @ wt. of 2.79 kg/mt)
Vertical member Shutter style =
mm x 44 mm x 3.00(of Jindal Section
No.19509 @ wt. of 1.51 kg/mt).with
12mmth. both side pre laminated
particle board (novapan) conforming to
IS: 12823 Grade 1 Type II in panelling
fixed in aluminium door consisting of
outer frame shutter as per design with
two pairs of standard handles, two pair
of concealed shoot bolts 250mm long
and pin type narrow style lock and
thumb turn from the other side,
including all fixtures, fastening etc.
complete as directed and as per
drawing and design. Rate including
hinges/Pivots and making provision for
fixing of fitting wherver required
including the cost of EPDM
rubber/neoprene gasket required
Anodised aluminium (work for all floors)
52 5.67 Providing and fixing in position 5980.75 Rupees Five Qui
collapsible steel shutters with vertical Thousand ntal
channels 20 x 10 x 2 mm braced with Nine
flat iron diagonals 20 x 5 mm size with Hundred
top and bottom rails of T_rin 40x 40 x 6 Eighty And
mm with 38mm dia, steel pulleys Paise
complete with bolts, nuts, locking Seventy Five
arrangements, stoppers handles Only
including applying a priming coat of red
53 216.75 Providing and fixing of decorative 391.88 Rupees Kg
stainless steel SS 304 Non magnetic Three
best quality Railing as per approved Hundred
sample. The SS304 Railing shall be fix on Ninety One
the edge or periphery of staircase & And Paise
steps as per detail design and Eighty Eight
instruction .The top horizontal SS pipe Only
should be of 50 mm Diameter with
minimum 16/14 gauge pipe thickness
and in between two horizontal pipe
mm diameter with minimum 16/14
gauge pipe thickness , the vertical pillar
pipe shall be of 50mm diameter with
minimum 14/12 gauge pipe wall
thickness , including SS pipe bending
SS 304 square sandwich and distance
peace for fitting & assembly at
extension joint as per detail design . The
Providing and fixing of SS railing
including cutting, fabrication ,SS arc
welding, grinding , erection , fixing with
necessary machinery tools, tackles,
labor and required civil work as per
detail design at specific location The SS
304 pipe railing should be fixed in the
floor/ wall by means of pipe socket
bush ,flange, bullet S.S bolt, S.S L end
key and other necessary hardware and
consumable required to complete in all
aspect . The item includes buffing,
polishing , assembling of the different
unit of SS pipe Railing and required civil
work for the fixing of the SS 304 railing
up to all floor in perfect position etc
complete as per approved sample as
directed by engineer in charge.
54 2497.5 Providing and fixing MS grill of required 110.09 Rupees One Kg
pattern to frames of window etc. with Hundred Ten
MS flats at required spacing and frame And Paise
around square or round bar with round Nine Only
headed bolts and nuts or by screw
Ornamental grill/Jali (Similar item) as
per detail design with two coats of
primer & two coats of enamel paints
the grill design and colour shade as per
instruction of engineer in charge etc
55 4.2 Providing and fixing 18 mm thick 2816.89 Rupees Two Smt
approved quality Marble stone mirror Thousand
polished, machine cut counter for Eight
Vanity counter , wash basin with Hundred
support and stability which include zeri Sixteen And
cutting refitting , plastering making Paise Eighty
good of surfaces , vanity counters Nine Only
fascias patti of Marble stone with
molding, cut out for wash basin sink
required sizes of approved shade,
texture and color laid in zeri in line level
and plumb with cutting out v section
claning out wetting grouting with
cement slurry 1: 3( 1 cement : 3 Coarse
sand ) with joints treated with white
cement mixed with matching pigment
epoxy touch ups incl. rubbing, Mirror
polishing curing etc. complete at all
levels as per instruction of Architect or
engineer in charge.
56 76.12 Providing and fixing pre-cast Rubber 704.07 Rupees Smt
Dye / steel Dye inter locking concrete Seven
block 60mm thick with grade of Hundred
concrete M300 pnumatic compressed / Four And
vibrated mechanically and as per Paise Seven
approved design Confirming to IS 15658 Only
: 2006 including 35 mm Sand layer for
levelling and filling the joint with sand in
proper line and level as per guidlines of
IRC : SP 63-2018 etc. Complete
57 76.12 Providing and fixing pre-cast concrete 370.68 Rupees Rmt
kerb stone of gray cement based Three
concrete block 30cm length,30cm Hundred
height and 15cm thick of M250 grade Seventy And
concret as per approved design and Paise Sixty
including excavation for fixing in proper Eight Only
line and level,filling the joint with C:M
1:3 (1cement:3fine sand) etc complete.
58 2 Providing and fixing of CIRCULAR 4252.10 Rupees Four Eac
counter type wash basin having size of Thousand h
470 x 470 x 200 mm counter type with Two
CI / MS/SS clamps or fastener as per Hundred
approved sample .The counter type Fifty Two
wash basinin should be of ivory colour . And Paise
The Item shall be including painting of Ten Only
fittings and brackets, cutting and
making good the walls and floors
wherever required including mior civil
and painting works & fitting up to all
fllor with all lead & lift as per detial
specification , approved sample and as
per instruction of Architect & engineer
59 2 Providing and fixing of pillar tap 1/2" 1798.81 Rupees One Eac
with capstan head. screw down high Thousand h
pressure with screws, shanks and back Seven
nuts.(A) 15 mm dia. as approved by Hundred
engg. in charge with necessary hex Ninety Eight
nipple fitting, Teflon tap and other And Paise
consumable and labor etc complete up Eighty One
to ALL floor level with all lead and lift Only
including mior civil and painting works
& fitting up to all fllor with all lead & lift
as per detial specification , approved
sample and as per instruction of
Architect & engineer in charge
60 2 providing and fixing of Angular stop 653.47 Rupees Six Eac
cock with wall flange with necessary Hundred h
hex nipple fitting, Teflon tap and other Fifty Three
consumable and labor etc complete 15 And Paise
mm dia approved by engineer in charge Forty Seven
with necessary coupling of approved Only
quality for wash basin. including fixing
in pipe line etc complete up to sixth
floor level with all lead and lift
including mior civil and painting works
& fitting up to all fllor with all lead & lift
as per detial specification , approved
sample and as per instruction of
Architect & engineer in charge
61 2 Providing and fixing chromium plated, 295.80 Rupees Two Eac
bottle trap with necessary couplings of Hundred h
approved quality for wash basin. Ninety Five
62 2 Providing and fixing wire braded PVC 177.76 Rupees One Eac
Connection flexible pipe of approved Hundred h
brand with brass union on both ends Seventy
with ferule type connector 45 cm long Seven And
and 15 mm nominal bore un plasticized Paise
wire braded PVC Connection pipe for Seventy Six
angle cock (in let) of following size. (A) Only
15 mm dia etc complete up to all floor
level with all lead and lift including mior
civil and painting works & fitting up to
all fllor with all lead & lift as per detial
specification , approved sample and as
per instruction of Architect & engineer
63 2 Providing and fixing C.P. brass waste for 67.91 Rupees Sixty Eac
washbasin or sink. (A) 32mmdia. Seven And h
64 2 Providing and fixing of C.P. brass 924.15 Rupees Nine Eac
Towel Ring Square with rubit clean with Hundred h
screws, hardware as approved by client Twenty Four
.The item includes fixing on wall/tiles And Paise
with necessary screw , fitting, Teflon tap Fifteen Only
, other consumable and labour with
minor civil work etc complete up to
sixth floor level with all lead and lift etc.
complete, including mior civil and
painting works & fitting up to all fllor
with all lead & lift as per detial
specification , approved sample and as
per instruction of Architect & engineer
65 2 Providing and fixing PVC SWR Nahni 585.37 Rupees Five Eac
trap IS 14735 for drain - 100 mm Hundred h
diameter with jali of the following Eighty Five
nominal diameter of self cleansing And Paise
design with C.I scread down or hinged Thirty Seven
grating including the cost of cutting and Only
making good the walls.
66 2 Providing and fixing S.W.gully trap with 1246.92 Rupees One Eac
C.I.grating brick masonry chamber and Thousand h
water tight c.i. cover with frame of 300 Two
mm x 300 mm size (inside )with Hundred
standard weight. (I) square month Forty Six And
traps.150 mm x 100 mm size p or r type Paise Ninety
67 2 constructing brick masonry chamber for 2932.93 Rupees Two Eac
under ground c.I. Inspection chamber Thousand h
and band with bricks having crushing Nine
strenght not less than 35 kg/cm2 in Hundred
cm 1:5. c.i. cover with frame (light duty) Thirty Two
455 mm x 610 mm internal dimension, And Paise
total weight of cover with fram to be Ninety Three
not lass then 38 kg.weight of cover Only
23kg and wt. of frame 15 kg ) r.c.c top
slab with 1:2:4 mix (1 cement:2 sand:4
aggregates 20 mm size) foundation
concrete 1:5:10 ,in side plaster 15 mm
thick with cement mortar 1:3 finished
smooth with a floating coat of neat
cement on walls and bed concrete etc.
complete.) (1) inside dimension 455 mm
x 610 mm and 450 mm deep for single
68 2 constructing. manhole with r.c.c slab in 11042.74 Rupees Eac
1:2:4 mix (1 cement:2 sand:4 Eleven h
aggregates 20 mm size) foundation Thousand
concrete 1:3:6( 1 cement:3 sand :6 brick Forty Two
bats 40+50 mm size ,in side plaster 15 And Paise
mm thick with cement mortar 1:5 (1 Seventy Four
cement: 5 coarse sand) finished with a Only
floating coat of neat cement and
making channels in cement concrete
1:2:4 (1 cement:2 coarse sand :4 stone
aggregate 20 mm) finished smooth
complete including curing and testing.
(i) inside size 900 mm x 1200mm and
1:5 mm deep including C.I.cover with
frame size 560mm total weight of cover
and frame to be not less than 128 kgs.
(wt of frame 64 kgs) (A) with 230cm
thick walls of brick masonary using brick
having crushing strength not less than
35 kgs/sq cm. in cement mortar 1:5 (1
cement :5 coarse sand) (1) A type depth
0.90 meter 150 mm diameter sewer
69 2 constructing. manhole with r.c.c slab in 19349.63 Rupees Eac
1:2:4 mix (1 cement:2 sand:4 Nineteen h
aggregates 20 mm size) foundation Thousand
concrete 1:3:6( 1 cement:3 sand :6 brick Three
bats 40+50 mm size ,in side plaster 15 Hundred
mm thick with cement mortar 1:5 (1 Forty Nine
cement: 5 coarse sand) finished with a And Paise
floating coat of neat cement and Sixty Three
making channels in cement concrete Only
1:2:4 (1 cement:2 coarse sand :4 stone
aggregate 20 mm) finished smooth
complete including curing and testing.
(i) inside size 900 mm x 1200mm and
1:5 mm deep including C.I.cover with
frame size 560mm total weight of cover
and frame to be not less than 128 kgs.
(wt of frame 64 kgs) (A) with 230cm
thick walls of brick masonary using brick
having crushing strength not less than
35 kgs/sq cm. in cement mortar 1:5 (1
cement :5 coarse sand) (1)B type depth
1.50 meter 150 mm diameter sewer
70 8 Providing and fixing conceled center 170.36 Rupees One Rmt
point to wall celling and floor CPVC PIPE Hundred
(SDR -13.5) pipe having NSFseal for Seventy And
portable water of following dia nominal Paise Thirty
bore ,tube ,fittings, and clamp including Six Only
making good the wall, ceiling and floor.
71 32 Providing and fixing conceled center 253.82 Rupees Two Rmt
point to wall celling and floor CPVC PIPE Hundred
(SDR -13.5) pipe having NSFseal for Fifty Three
portable water of following dia nominal And Paise
bore ,tube ,fittings, and clamp including Eighty Two
making good the wall, ceiling and floor. Only
72 30 Providing and fixing conceled center 447.72 Rupees Four Rmt
point to wall celling and floor CPVC PIPE Hundred
(SDR -13.5) pipe having NSFseal for Forty Seven
portable water of following dia nominal And Paise
bore ,tube ,fittings, and clamp including Seventy Two
making good the wall, ceiling and floor Only
73 40 Providing and fixing conceled center 653.77 Rupees Six Rmt
point to wall celling and floor CPVC PIPE Hundred
(SDR -13.5) pipe having NSFseal for Fifty Three
portable water of following dia nominal And Paise
bore ,tube ,fittings, and clamp including Seventy
making good the wall, ceiling and floor Seven Only
74 24 providing & fixing to wall ceiling and 280.23 Rupees Two Rmt
floor 10 kg/f/cum working pressure Hundred
polyethylene pipes of the following Eighty And
outside diameter ,low density complete Paise Twenty
with special flange compression type Three Only
fittings ,wall clamped making good wall
,cling and floor - 75 mm dia
75 30 providing & fixing to wall ceiling and 339.05 Rupees Rmt
floor 10 kg/f/cum working pressure Three
polyethylene pipes of the following Hundred
outside diameter ,low density complete Thirty Nine
with special flange compression type And Paise
fittings ,wall clamped making good wall Five Only
,cling and floor - 110 mm dia
76 2 Providing and fixing ball cock of 189.84 Rupees One Eac
approved. quality as directed.(A) Hundred h
Copper Metal (ii) 50mm dia. Eighty Nine
77 2 Providing and fixing ball cock of 132.89 Rupees One Eac
approved. quality as directed.(A) Hundred h
Copper Metal (ii)25 mm dia. Thirty Two
78 2 providing and fixing gun metal check or 663.43 Rupees Six Eac
non return full way wheel valve ( E ) 40 Hundred h
mm mm diameter of approved quality , Sixty Three
fixing as directed up to all lead and lift And Paise
as directed by engineer in chrage Forty Three
79 1 Making connection of galvanized Mild 913.09 Rupees Nine Eac
steel distribution branch with Hundred h
galvanized mild steel main 50mm to Thirteen And
80mm nominal bore by providing and Paise Nine
fixing tee including cutting and Only
threading the pipes complete.
Electric work Rupees Nil
80 188 Point wiring for Light / Bell with 2-1.5 485.81 Rupees Four Pt
sq.mm & earthwire of 1.5 sq.mm Hundred
(Green) both are of ISI marked 1.1 KV Eighty Five
grade FRLS PVC insulated multistrand And Paise
copper wires, in following type of pipe Eighty One
to be erected concealed in/ on surface Only
on wall/ceiling complete with 6A
Modular type switch / bell push &
accessories and earth continuity of
following type, erected on PVC /
Metallic box, single mounting base
frame covered with textured/metallic
front plate modules erected on / in wall
/ ceiling as per pipe erected, with
necessary Lamp holder / ceiling rose /
H.D.Connector as directed.(f) with
medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete CAT III
81 36 Point wiring for FAN with 2-1.5 sq.mm 674.68 Rupees Six Pt
& earthwire of 1.5 sq.mm (Green) both Hundred
are of .ISI marked 1.1 KV Grade FRLS Seventy Four
PVC insulated multistrand copper wires, And Paise
in following type of pipe to be erected Sixty Eight
concealed in / flushed on wall/ceiling Only
complete with 6A Modular type switch
and hum free EME four or more step
type electronic fan regulator with
separately mounted and accessories
with earth continuity of following type
erected on PVC / Metallic box, single
mounting base frame covered with
textured/metallic front plate modules
erected on / in wall / ceiling as per pipe
erected. with necessary ceiling rose /
H.D.Connector as directed.(f) with
medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling completecat III
82 42 Providing following type of Modular 151.50 Rupees One Pt
Type Accessories mounted with PVC / Hundred
metallic/Wooden box, single mounting Fifty One
base frame covered with textured / And Paise
metallic/white front plate , modules Fifty Only
erected with necessary connections as
per site situation directed by Engineer
In charge.(1)One No. SP 6 Amp. Cat. III
83 42 Providing following type of Modular 151.50 Rupees One Pt
Type Accessories mounted with PVC / Hundred
metallic/Wooden box, single mounting Fifty One
base frame covered with textured / And Paise
metallic/white front plate , modules Fifty Only
erected with necessary connections as
per site situation directed by Engineer
In charge.(2) One No 5 pin plug. Cat. III
84 21 Point wiring for Individual Plug with & 745.38 Rupees Pt
earthwire of 1.5 sq.mm (Green) both Seven
are of ISI marked 1.1 KV grade FRLS PVC Hundred
insulated multistrand copper wires, in Forty Five
following type of to be erected And Paise
concealed in / on surface of wall / Thirty Eight
ceiling complete with Modular type Only
switch & 5 pin Plug erected on PVC /
Metallic box covered with appropriate
front plate modules erected on / in wall
/ ceiling as per pipe erected with
following type of accessories. [II] For
16A Plug and 16 amp switch with 2-2.5
sq.mm Cu. Wire from mcb db board. (f)
with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete Cat. III
85 21 Point wiring for Individual Plug with & 871.63 Rupees Eight Pt
earthwire of 1.5 sq.mm (Green) both Hundred
are of ISI marked 1.1 KV grade FRLS PVC Seventy One
insulated multistrand copper wires, in And Paise
following type of to be erected Sixty Three
concealed in / on surface of wall / Only
ceiling complete with Modular type
switch & 5 pin Plug erected on PVC /
Metallic box covered with appropriate
front plate modules erected on / in wall
/ ceiling as per pipe erected with
following type of accessories.[III] For
16A Plug and 16 amp switch with 2-4
sq.mm Cu. Wire with 2.5 sq.mm ( green)
earthing wire from mcb d b board. (f)
with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete Cat. III
86 36 Point wiring for on board Looped Plug 257.55 Rupees Two Pt
with 6A Modular type switch & 5 pin Hundred
socket erected on PVC / Metallic / Fifty Seven
Wooden box, single mounting base And Paise
frame covered with textured / metallic Fifty Five
/white front plate modules erected on Only
/ in wall / ceiling with following type
accessories cat III
87 10 Providing following type of Modular 25.25 Rupees Ea.
Type Accessories mounted with pvc / Twenty Five
metallic box, single mounting base And Paise
frame covered with textured / metallic Twenty Five
front plate , modules erected with Only
necessary connection. As desired by
Engineer In charge. (7) Blank Plate
88 1 Providing following type of Modular 160.59 Rupees One Ea.
Type Accessories mounted with pvc / Hundred
metallic box, single mounting base Sixty And
frame covered with textured / metallic Paise Fifty
front plate , modules erected with Nine Only
necessary connection. As desired by
Engineer In charge. (8) Computer RJ-
89 100 Supplying & erecting Delton or 20.20 Rupees Mtr
approved make Telephone Cable Twenty And
electrolytic copper conductor PE Paise Twenty
insulation twisted in two pairs, & Only
wrapped with FRLS PVC tape &
sheathed with FRLS PVC or HFFR outer
Jacket suitable for telephone wiring &
confirming to C-DOT erected in existing
pipe. of following size of conductors &
nos.of pairs. With necessary
connections. [A] Conductor Size 0.5 mm
(b) Armoured [Jelly Filled] (2) 2 PAIR
90 200 Providing and erecting ISI mark Medium 24.24 Rupees Mtr
class RIGID PVC PIPES of following size Twenty Four
complete to be erected on/in wall or And Paise
ceiling erected with necessary PVC Twenty Four
fittings & Junction boxes fixed with Only
adhesive solution & Clamps with
following diameter of pipes, in
approved manner as directed (a)
91 50 Providing & erecting PVC Corrugated 17.17 Rupees Mtr
Flexible Conduit with required nos. of Seventeen
coupling, PVC bushes, Check-nuts etc. And Paise
complete of following sizes.(2) 25 mm Seventeen
92 250 Providing and erecting Mains with 1.1 62.62 Rupees Sixty Mtr
KV grade FRLS PVC insulated ISI marked Two And
stranded Copper conductor wire in Paise Sixty
following type of pipe to be erected Two Only
concealed in /flushed on wall/ceiling,
with 1.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green
colour for earth continuity of following
size (a) with medium class Rigid PVC
pipe and accessories(a) 2 wire 1.5 sq.
93 1500 Providing and erecting Mains with 1.1 82.82 Rupees Mtr
KV grade FRLS PVC insulated ISI marked Eighty Two
stranded Copper conductor wire in And Paise
following type of pipe to be erected Eighty Two
concealed in /flushed on wall/ceiling, Only
with 1.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green
colour for earth continuity of following
size (a) with medium class Rigid PVC
pipe and accessories (b) 2 wire 2.5 sq.
94 250 providing and erecting Mains with 1.1 124.23 Rupees One Mtr
KV grade FRLS PVC insulated ISI marked Hundred
stranded Copper conductor wire in Twenty Four
following type of pipe to be erected in / And Paise
on wall / ceiling with 2.5 sq. mm copper Twenty
conductor FRLS PVC insulated stranded Three Only
wire of green colour for earth continuity
of following size (a) with medium class
Rigid PVC pipe and accessories.(a)
95 100 providing and erecting Mains with 1.1 180.79 Rupees One Mtr
KV grade FRLS PVC insulated ISI marked Hundred
stranded Copper conductor wire in Eighty And
following type of pipe to be erected in / Paise
on wall / ceiling with 2.5 sq. mm copper Seventy Nine
conductor FRLS PVC insulated stranded Only
wire of green colour for earth continuity
of following size (a) with medium class
Rigid PVC pipe and accessories g) 4 wire
96 100 providing and erecting Mains with 1.1 147.46 Rupees One Mtr
KV grade FRLS PVC insulated ISI marked Hundred
stranded Copper conductor wire in Forty Seven
following type of pipe to be erected in / And Paise
on wall / ceiling with 2.5 sq. mm copper Forty Six
conductor FRLS PVC insulated stranded Only
wire of green colour for earth continuity
of following size (a) with medium class
Rigid PVC pipe and accessories(b) 2 wire
97 100 providing and erecting Mains with 1.1 425.21 Rupees Four Mtr
KV grade FRLS PVC insulated ISI marked Hundred
stranded Copper conductor wire in Twenty Five
following type of pipe to be erected in / And Paise
on wall / ceiling with 2.5 sq. mm copper Twenty One
conductor FRLS PVC insulated stranded Only
wire of green colour for earth continuity
of following size (a) with medium class
Rigid PVC pipe and accessories(i) 4 wire
10 sq. mm (use earth wire of 4 sq.mm )
98 50 Providing & Erecting approved make 39.39 Rupees Mtr
following size of TV Co-axial flexible Thirty Nine
cable comprising inner conductor of And Paise
solid bare copper insulated with Foam Thirty Nine
PE & Secondary conductor made of poly Only
- Aluminium film bonded Al. Braids @
suitable coverage overall sheathed
with black PVC insulation. b).RG-6
99 500 Supplying & erecting approved make 47.47 Rupees Forty Mtr
LAN cable of following size in existing Seven And
pipe as per direction[C] CAT - 6 Paise Forty
100 19 Providing & erecting Switch board for 1133.22 Rupees One Ea.
Computer or electric apparatus Thousand
consisting of following modular type One
accessories mounted with PVC / Hundred
Metallic concealed /open box with Thirty Three
single mounting base frame covered And Paise
with textured/metallic /white front late, Twenty Two
modules erected with necessary Only
connections as directed 1 no. 6A /16A
universal plug-switch combined.3 nos.
6A Switch 3 nos. 6A 5 pin Plug For
Modular Type Accessories CAT III
101 1 Supplying & erecting Approved make 148.47 Rupees One Ea.
call bell indicator with buzzing sound Hundred
and Red light indicating lamp with Red Forty Eight
light button to attend the call suitable And Paise
for 240 v 50 c/s supply to be erected. Forty Seven
102 10 Supplying and erecting LED indoor 112.11 Rupees One Ea.
fittings with LEDs of wattage 0.2 Watt Hundred
to 0.5 Watt assembled on single Twelve And
MCPCB, with housing used as a heat Paise Eleven
sink shall be made of thick sheet Steel Only
conforming to IS: 513/CRCA/ aluminium
die cast powder coated and high U.V. &
corrosion resistance with diffuser with
company mark/name 120 to
V,Power Factor more than 0.9, THD <
%, CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens /watt ,LED
efficiency-110 lumens /wattLED driver
efficiency > 85 % CREE / OSRAM /
PHILIPS Lumileds / NICHIA / SEOUL
/Bridgelux make LED used for
luminaire. ( fitting required LM-79 &
LM-80 Certificates )(NOTE: Below
description have shown ranges of
Wattage capacity of LED fittings.The
Engineer incharge may select any
wattage capacity between the ranges
shown.) (A) Tube Light with integral
driver (a) 5-9 Watts, Surge-2 KV, IP-20,2
103 156 Supplying and erecting LED indoor 589.84 Rupees Five Ea.
fittings with LEDs of wattage 0.2 Watt Hundred
to 0.5 Watt assembled on single Eighty Nine
MCPCB, with housing used as a heat And Paise
sink shall be made of thick sheet Steel Eighty Four
conforming to IS: 513/CRCA/aluminium Only
pressure die cast powder coated and
high U.V. & corrosion resistance with
diffuser housed in aluminium casted
body with company mark/name 160V
to 270V,Power Factor more than 0.95,
THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 % ( fitting
required LM-79 & LM-80
Certificates)(NOTE: Below description
have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge
may select any wattage capacity
between the ranges shown.) (A)
Square/ Circular shaped
Surface/Recessed Mount Downlight
with provision for spring loaded
mounting clips complete.IP20 (iii) 16-20
watts, Surge-2 KV CAT III
104 2 Supplying and erecting LED street light / 7266.95 Rupees Ea.
Flood light fittings with High power Seven
White LEDs wattage of 1Watt and Thousand
above assembled on single MCPCB, Two
efficiency more than 130 lm/w and Hundred
corrosion free High pressure die cast Sixty Six And
aluminum housing with smooth finish Paise Ninety
powder coated and heat sink extruded Five Only
aluminium with diffuser and
Polycarbonate optics/ lenses with
company mark/name engraved or
embossed 120 to 300 V,Power Factor
more than 0.95, THD < 10 %, CCT
K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt .
LED driver efficiency > 85 %.CREE /RAM
/ PHILIPS Lumileds / NICHIA / SEOUL/
dgeLux (U.S.A.) make LED used for
luminaire. ( fittings required LM-79 &
LM-80 certificates) (NOTE: Below
escription have shown ranges of
Wattage capacity of LED fittings.The
Engineer incharge may select any
wattage capacity between the ranges
shown.) (B) Flood Light (IP-65), Surge
protection -4KV integral and ,Light must
have 440VAC line supply with over-
voltage protection. (iv) above 90 to
105 20 Providing and erecting required size 794.87 Rupees Kg.
Copper strip for earthing of H.T. OCB / Seven
ACB/ Transformer, LT panel board, Hundred
Motors etc. using copper clamp. Ninety Four
106 2 Supplying & erecting earth pit of 5760.03 Rupees Five Ea.
minimum bore dia.150mm size Thousand
approved make Earthing Electrode Seven
consisting Pipe-in-Pipe Technology as Hundred
per IS 3043-1987 made of corrosion Sixty And
free hot dipped G.I.Pipes having Outer Paise Three
pipe dia of 50mm having 80-200 Only
Micron galvanising, Inner pipe dia of
mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with
constant ohmic value surrounded by
highly conductive compound with high
charge dissipation suitable for following
type of applications with chamber and
heavy duty cover.(approved make OEM
has to submit test certificate) & having
back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:-
0.2 W/ meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load
& dry form, Sulphar content:- <2%(C)
Back fill Compound :- Earthing
compound should be capable to retain
moisture for long time Necessary test
report must be submitted. (b)For
Electrical installation up to 11 KV in
normal soil. Length of Pipe : 2.00 mtrs
Back filling Compound :1 no. Bag of
107 120 Providing and erecting XLPE(IS:7098)(I)- 540.35 Rupees Five Mtr.
88 ISI armoured cable multistrand Hundred
Aluminium conductor for 1.1 KV. to be Forty And
laid on wall with necessary clamps or in Paise Thirty
existing trench / pipe of following size Five Only
of cables (E) 3 1/2 core 120 Sq. mm (
Sq. mm 1/2 core)
108 50 Making trench in soft soil of suitable 55.55 Rupees Fifty Mtr.
width of 90 cms deep for laying cable or Five And
locating the fault all over the run and Paise Fifty
back filling the same and making the Five Only
surface as a normal ground.
109 50 Covering of cable with second class 140.39 Rupees One Mtr.
bricks or cement tiles laid cover the Hundred
cable crosswise & also on both sides Forty And
with covering of 7. 5 Cms. layer of sand Paise Thirty
above & below cable (16 bricks per Nine Only
110 2 Providing and fixing heavy duty flange 38.38 Rupees Ea.
type brass cable gland with rubber ring Thirty Eight
for PVC insulated armourd cable And Paise
complete with out going tails, insulating Thirty Eight
tape etc. for following size of cables. d) Only
2 to 4 Core 10 Sq.mm
111 4 Providing and fixing heavy duty flange 140.39 Rupees One Ea.
type brass cable gland with rubber ring Hundred
for PVC insulated armourd cable Forty And
complete with out going tails, insulating Paise Thirty
tape etc. for following size of cables. (E) Nine Only
3 & 1/2 core 120 Sq. mm
112 20 Solderiess crimping type Aluminum lugs 13.13 Rupees Ea.
conforming to IS suitable for cable of Thirteen And
following size evenly crimped with high Paise
pressure tool & connected to Thirteen
switchgear terminals with brass / Only
cadmium plated nut bolts in as
approved manner A)B) 10 Sq.mm.
113 40 Solderiess crimping type Aluminum lugs 45.45 Rupees Forty Ea.
conforming to IS suitable for cable of Five And
following size evenly crimped with high Paise Forty
pressure tool & connected to Five Only
switchgear terminals with brass /
cadmium plated nut bolts in as
approved manner (H) 120 Sq.mm.
114 1 Providing & erecting weather proof, 14902.55 Rupees Sqm
dust & vermin proof, floor mounted Fourteen t
front operated indoor type cubical Thousand
panel board necessary IP-42 and above Nine
protection as per approval from Hundred
engineer incharge made from 14 SWG Two And
thick CRC M.S. sheet for outer body & Paise Fifty
doors, 16 SWG thick CRC M.S.sheet for Five Only
internal partitions with necessary
accesories , supporting angles/ flats
channel including cutting, bending,
drilling, welding, riveting with internal
partitions & cable alley as per
requirements & instruction of engineer-
in-charge with erection of supplied
switch gears, BUSBARS, suitable size of
inter connecting PVC copper wire /
copper-aluminium strips, rubber
grommets, rib, bakelite control
fuses/MCB for measuring instruments,
earth bus & earth bolts, foundation
flange - bolts-base Plates, sufficient nos.
of hinged doors, handles with locking
arrangement and rubber gasket,heavy
duty end terminal connection,danger
notice board,necessary
ventilation,earthing strip complete. The
Panel shall be painted with epoxy
powder coating.
0 (The rates excludes the cost of 0.00 Rupees Nil 0.00 -
switchgears, bus bars, inter connecting
mains, meters Fuses etc. The dimension
shall be measured excluding base
beams). The panel shall be supplied
with following approved manufacturers
with following size.(A) The standard
companies switch gear shall be used
and only manufacturers at CPRI
approved factory and shall be certified
by that company whose switch gears
are used after fabrication for beneficial
use. (I) with 350mm depth
115 2 Operational Handle Assembly Complete 754.47 Rupees Ea.
for up to 800A.(Rotry Handal) Seven
116 2 Supplying and erecting triple pole & 5752.96 Rupees Five Rmt
neutral 440V/ 500V panel mounting Thousand .
Aluminium Busbars with four equal Nos. Seven
of bus having current density not more Hundred
than 0.8 Amp. / sq.mm (Rated current / Fifty Two
cross section area) duly wrapped with And Paise
colour insulating tape for phase Ninety Six
sequence of following current carrying Only
capacity, erected with necessary bus
bar supports /insulators, main cable
socket to each busbar,erected in
existing cubical panel with necessary
connections. (E) Suitable for 400 Amp.
117 1 Approved make Four pole moulded case 6173.12 Rupees Six Ea.
circuit breaker having breaking capacity Thousand
ICU of 25 KA. at 415 V,having normal One
current rating up to 25 A to 100A. with Hundred
Fixed thermal & magnetic release Seventy
suitable to work on A.C. supply 50 c/s. Three And
with all internal connections & Paise Twelve
complete erected in existing 16 G.M.S. Only
housing. ICS=100% ICU only CAT III
118 36 Providing & erecting Approved make 1948.29 Rupees One Ea.
Power Saving 50 Watt Ceiling Fan with Thousand
double ball bearing ISI mark with Nine
Condenser 230 volt A.C. 50 Hz 1200 Hundred
mm sweep complete having 3blades Forty Eight
with aluminium blades with , canopy & And Paise
30 cm. down rod erected with Twenty Nine
earthing.(Make shall be approved by Only
Engineer in charge)
119 36 Supplying and erecting 19 / 20 mm. 108.07 Rupees One Mtr
nominal bore Medium Class M.S. Pipe Hundred
down rod erected duly painted for fan Eight And
complete with necessary 24/ O.20, 3 Paise Seven
core flexible wire with earthing. Only
120 36 Supplying & erecting Fan Hook of 10 43.43 Rupees Forty Ea.
mm M.S. Round bar grouted in RCC slab Three And
with Making the site as original. Paise Forty
121 36 Supplying & erecting fan hook box of 108.07 Rupees One Ea.
10 mm M.S. round bar bounded to the Hundred
RCC bars up to 50mm length each side Eight And
and pierced through a 16 Gauge M.S. Paise Seven
box / Heavy Duty PVC box complete Only
erected concealed in Ceiling with
necessary finishing.
122 36 Providing 2.5mm.thick laminated acrylic 18.18 Rupees Ea.
sheet to cover the fan hook or Fan box. Eighteen And
123 1 Supplying & erecting single phase 2740.13 Rupees Two Ea.
approved make industrial exhaust fan Thousand
suitable for medium duty ring mounted Seven
low noise operation suitable for Hundred
medium duty having following dia size Forty And
and maximum speed in RPM[B] 380 mm Paise
dia 900 RPM Thirteen
124 1 Providing suitable M.S. louver shutter of 368.65 Rupees Ea.
the Exhaust fan. Three
125 1 Providing recess in wall or window 189.88 Rupees One Ea.
frame suitable for erection of Exhaust Hundred
fan complete with plastering and colour Eighty Nine
washing to match the colour of the wall And Paise
or window complete with expanded Eighty Eight
metal in order to render the fitting in Only
accessible and the room water-proof.
126 5 providing and erecting Mains with ISI 56.56 Rupees Fifty Mtr
marked, 1.5KV grade electrolyte multi Six And Paise
stranded, annealed copper conductor Fifty Six Only
with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in
existing pipe of following size
(Specifically for control panel, relays,
power switchgears, motor starters &
control wiring) with required size of
copper lugs, nuts and bolts if required.
.(e) One wire 6.00 sq. mm
127 5 providing and erecting Mains with ISI 91.91 Rupees Mtr
marked, 1.5KV grade electrolyte multi Ninety One
stranded, annealed copper conductor And Paise
with heat resistant PVC insulated Ninety One
conforms to IS 694, IEC - 227 erected in Only
existing pipe of following size
(Specifically for control panel, relays,
power switchgears, motor starters &
control wiring) with required size of
copper lugs, nuts and bolts if required..
f) One wire 10.00 sq. mm
128 5 providing and erecting Mains with ISI 142.41 Rupees One Mtr
marked, 1.5KV grade electrolyte multi Hundred
stranded, annealed copper conductor Forty Two
with heat resistant PVC insulated And Paise
conforms to IS 694, IEC - 227 erected in Forty One
existing pipe of following size Only
(Specifically for control panel, relays,
power switchgears, motor starters &
control wiring) with required size of
copper lugs, nuts and bolts if required.
g) One wire 16.00 sq. mm
129 5 providing and erecting Mains with ISI 236.34 Rupees Two Mtr
marked, 1.5KV grade electrolyte multi Hundred
stranded, annealed copper conductor Thirty Six
with heat resistant PVC insulated And Paise
conforms to IS 694, IEC - 227 erected in Thirty Four
existing pipe of following size Only
(Specifically for control panel, relays,
power switchgears, motor starters &
control wiring) with required size of
copper lugs, nuts and bolts if required..
h) One wire 25.00 sq. mm
130 1 Supplying and erecting approved make 5454.00 Rupees Five Ea.
Digital multi Fuction paramater for Thousand
measures and display, V, A, Hz, Kw, PF, Four
kva, kwh, Run HRS with Rs-485 with all Hundred
connection wiring etc. with Fifty Four
manufactures calibration certificate. Only
131 1 Supplying & erecting push button type 898.90 Rupees Eight Ea.
telephone instrument having speaker Hundred
phone Caller ID & hands free dialing Ninety Eight
system & 30 memories with display And Paise
system (a) Single line BEETEL/panasonic Ninety Only
or equivalent make
132 2 Providing printed instruction chart both 130.29 Rupees One Ea.
in English and Gujarati and duly framed Hundred
with front glasses, for treatment of Thirty And
person suffering from Electric shock Paise Twenty
133 2 Providing and erecting Sheet Steel 3412.79 Rupees Ea.
powder coated MCB distribution board Three
- flush / surface mounted fitted with Thousand
busbar, neutral link, earth bar and DIN Four
rail, Conforms to IS 8623-1 & 3, IEC Hundred
61439-1 & 3 without MCB to house Twelve And
appropriate nos. of MCBs.(The DBs Paise
should be used of same company of Seventy Nine
MCB to be used) suitable for(B) three Only
phase incoming and single phase
horizontal type outgoing Per phase
isolation type (PPI) (b) sheet steel
double door (iii)8 way
134 9 Approved make ELCBs / RCCBs 2235.13 Rupees Two Ea.
conforming to IS:12640 and having Thousand
sensitivity of 30 m A and Short Circuit Two
with stand capacity of 6KA and suitable Hundred
for operation on single phase 240 V Thirty Five
having characteristic of quick action & And Paise
tripping with all advance feature & do Thirteen
not incorporate any electronic Only
component for following Max. rating.
(ii) 40Amps. DP Cat III
135 70 providing and erecting Miniature circuit 112.11 Rupees One Ea.
breaker single pole 6A to 25A suitable Hundred
to operate on 240 V A.C. system and Twelve And
having breaking capacity 10 KA to be Paise Eleven
erected in existing box. confirming to IS Only
8828/1996 with ISI Mark Cat-III
136 4 Providing & erecting 415 V MCB Four 737.30 Rupees Ea.
Pole for Motor & Inductive Load (C Seven
Curve) having 10KA breaking capacity & Hundred
confirms to IS :8828 in existing box Thirty Seven
having following capacity (B) 63 And Paise
Amp. Cat-III Thirty Only
137 8 Providing and erecting approved make 30713.09 Rupees EA
split air-conditioning unit consisting of Thirty
copper condensing unit with fan motor, Thousand
hermetically sealed rotary compressor Seven
with accessories etc. duly connected Hundred
separately erected evaporating unit and Thirteen And
blower motor with its accessories by Paise Nine
means of extra supplied proper Only
insulated copper tubing,drain PVC pipes
suitable for ( cost includes powder
coated Stand, Eco Friendly green gas
charging, 15A plug top & Remote
Control) with necessary core cutting.
For 3 Star Rating of current year (b) for
1.5 ton capacity
138 10 Supplying and erecting insulated pair of 746.39 Rupees Rmt
soft copper tubing including power and Seven .
control cable,necessary PVC drain pipes Hundred
for Split AC machine up to 4 TR capacity Forty Six And
I/We am/are willing to carry out the work at… .................... % above/below percent ( Should Be written in figure
sand words) of the estimated rate mentioned above. Amount of my/our tender works out as under. Estimated
amount put to tender Estimated amount put to tender
I/We am/are willing to carry out the work at… ..................... %above/below percent
(Should be written in figures and words) of the estimated rate mentioned above.
Amount of my /our tender works out asunder.
Estimatedamountputtotender Estimatedamountputtotender
Deduct………%below Add………%Above
Inwords Inwords
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD VCC Technical Spec Schedule-B and Drawings.pdf
Important Instruction VCC.pdf
09 CC VCC.pdf
10 SC VCCC.pdf
2 A MEMORANDUM OF UNDERSTANDING FOR C.R 11 FEB 26.pdf
12_TESTING.pdf
Check list for bidders-2.pdf
Check list for bidders.pdf
20_DTP CHEKLIST.pdf
5_MEMORANDUM OF UNDERSTANDING 05122024.pdf
4.5_ALL CONDITIONS 05122024.pdf
16_For Safety inst-.pdf
9_Electrical SPECIFICATIONS-05122024.pdf
8_SPECIFICATION BUILDING CIVIL SPECIFICATIONS- 05122024.pdf
15_AFFIDAVIT DOC DETAIL-.pdf
17_GR Part 1.pdf
17_GR Part 2.pdf
06 NOTIFICATION - Standards for cement consumption 16 dec.pdf
05 IS Codes 16 dec.pdf
6_site office plan.... -05122024.pdf
Schedule-B for VCC.pdf
SBD for VCC Navsari.pdf
07 VCC LAYOUT C SIZE A3.pdf
08 SECTION SIZE A3.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .