Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹12.4 L+₹61,860.04 (5.27%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹12.5 L+₹72,983.36 (6.22%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹12.6 L+₹81,321.06 (6.93%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹13.3 L+₹1.5 L (13.1%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹13.2 L
EMD Value
₹26,500
Closing Date
14 Sept 2022, 10:00 amClosed
Executive Engineer, HPPWD Division Sangrah
Executive Engineer, HPPWD Division Sangrah
C/O link road from village Sail to Kelwad Sajkhil km. 0/00 to 6/500 (SH - C/O 900 mm dia Hume Pipe Culvert at RD. 2/640,2/690,3/945,5/090 and 5/875)
2022_PWD_64544_2
Sangrah 7098-8028 dated 30.08.2022
Open Tender
Civil Works
Item Rate
90 days
Sangrah
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
₹26,500
14 Aug 2024
7 Sept 2022
14 Sept 2022
7 Sept 2022
14 Sept 2022
7 Sept 2022
Amount
Excavation in soil in hilly area by Manual means including cutting and trimming of side slope and disposing of excavated earth a lift up to 1.5 mtr and a lead of 20mtrsas per technical specification clause 1603.1 including all leads, lifts and carriage of materials complete as per entire satisfaction of the Engineer in Charge.
Earth work in excavation for structure as per drawing and technical specification clause 305.1including setting out, construction of shoring and bracing,removoval of stumps and other deleterious material and disposal up to a lead of 50 meters dressing of sides and bottom and back filling trenches with excavated suitable material including all leads, lifts and carriage of materials complete as per entire satisfaction of the Engineer in Charge.
Providing and laying plain cement concrete 1:6:12 (One cement is to six sand is to twelve graded hard crushed stone aggregate nominal mix) mechanically mixed and vibrated in foudation or similar works complete as per drawings and technical specification of ministery of rural Development for rural road August 2004(Two thousand four) clause 802-803, 1202 and 1203 (eight hundred two, Eight hundred three , One thousand two hundred two and one thousnad two hundred three)as per drawings andtechnical specification of ministery or rural development for rural road and curing complete including cost of form work and hauling/ carriage of all labour equipments and materials to various locations through all modes of transportations in all leads and lifts to the entire specifications as per direction of Engineer- in-Charge
Providing and laying concrete for plain/reinforced concerete in open foundations complete as per drawing and technical specification clauses 802,803,1202 & 1203,(1:4:8 , 40 mm nominal size)as per HP.PWD specification 1990 volume-I, including carriage of all labour equipment and material to various location through all modes of transportation in all leads and lifts as per entire satisfaction of Engineer in charge.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and specification clause 802,803,1202 & 1203(PCC Grade M10 Nominal mix 1:3:6) 40MM including all leads,lifts and carriage of materials complete as per entire satisfaction of the Engineer in Charge.
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, back filling concrete and masonry work in head walls and parapets clause 1106. including all leads, lifts and carriage of materials complete as per entire satisfaction of the Engineer in Charge.
Backfilling behind abutment ,wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 with granular material including all leads, lifts and carriage of materials complete as per entire satisfaction of the Engineer in Charge.
Providing weep holes in brick masonry / stone masonry /plain reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full with of the structures with slop of 1(v):20(H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7 including all leads,lifts and carriage of materials complete as per entire satisfaction of the Engineer in Charge.
lokesh sharma
Praveen Chauhan
vijay singh thakur
Satish Thakur
HARISH THAKUR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .