Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC AOC | |
| 2 | L2₹38.7 L+₹36,133.50 (0.94%)Rejected-Finance | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹53.0 L+₹14.6 L (38.1%)Rejected-Finance | L3 | Rejected-Finance Rejected being |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
26 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NORTH) AMBALA CANTT
GE(NORTH) AMBALA CANTT
SPECIAL REPAIR TO BLDG NO P-55/13-20, P-56/21, P-56/27 AT ALBERT EKKA LINE, ADDITIONAL ALTERATION TO BLDG NO. P-07 (REPAIR BAY) AT SECTOR B-I IN THE AREA OF AGE B/R-I (N) AND CERTAIN MINOR WORKS IN THE AREA OF AGE B/R-I AND AGE E/M (N) UNDER
2022_MES_500944_1
GE(N)Amb-68/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE(NORTH) AMBALA CANTT
As per tender documents
8 documents required · 8 mandatory
₹500
GE(NORTH) AMBALA CANTT
₹96,000
Yes
5 Mar 2022
28 Jan 2022
28 Feb 2022
28 Jan 2022
26 Feb 2022
12 Feb 2022
28 Jan 2022 - 12 Feb 2022
60 days
Amount
Schedule 'A' Part-I (B/R itmes) Demolition of reinforced cement concrete in roofs, floors, beams, chajjas, staircases, landings and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete 1:1-1/2:3 (Nominal Mix) using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 CM thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge
M&L TMT steel bars 6 to 8mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M&L rendering 10 mm thick on fair faces of brick work or concrete ceiling or chajjas surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 15mm thick in cement mortar 1:6 on any faces of brick work or concrete wall surfaces and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in charge.
M&L rough cast plaster complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:4 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
Supply only water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 15 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:4 and finished even and fair without using extra cement but using water proofing compound @ 2% by weight of cement or as per manufacturer's instructions complete all as specified and as directed by the Engineer-in-Charge. (water proofing compound shall be measured and paid for separatally)
S&F box type using ERW hollow 'P' section ventilators fixed type with glazing bar including MS grills of square bar 10mm dia @ 100 c/c complete with glazing bars dovetailed or welded, including two coat of synthetic enamel ordinary tint paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of newly plastered / un--plastered surfaces of ceiling and applying three coats of white lime wash over prepared surfaces of ceiling complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered surfaces and applying two coats of oil bound distemper with painting roller over a coat of alkali resistant primer over and including 1 to 2 mm thick wall care putty white cement based in two or more coats to achive smooth surfaces complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregates as in sub base of floor and finished even and fair to receive tiles etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectangular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/ skirtings/dados of size 300x450x7mm/450x350x7mm thick or nearest size, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L light shade vitrified tiles premium quility joint free 10 mm thick (square/ rectangular) area of each tiles not exc 0.36 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match the surface over and including screed bed or bedding layer 15mm thick in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L light shade vitrified tiles premium quility joint free 10 mm thick (square/ rectangular) cut from tiles having area of each tiles not exc 0.36 Sqm in skirting etc set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutter from the frames) area n. exc 1.5 Sqm each and removal from site complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm each and removing the same from site complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by Engineer in Charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill fabricated from 10mm square bar as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
M & L rolled mild steel framed work as in door or gates of angle or other section with gusset plates, rails braces etc. complete, drilled for fixing for steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410-(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new steel and iron surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new wooden surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
S&F galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply only mild steel butt hinges 50 mm long medium weight and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel cold rolled butt hinges 100mm long medium weight complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 150 mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel butt hinges 100mm long medium weight complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
S&F 1 mm thick mild steel plain black sheet in wall cladding, steel gates and similar work cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up mitred angles etc as required, complete all as specified and as directed by the Engineer-in-Charge.
M & L figured glass, pin head type 3.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F as in repair mild steel door shutter two leaves with frame of 20 gauge MS sheet (all around) and leaves of 21 gauge MS Sheet ( all as per Godraj Pettern) with three way locking arrangement with brass lock with duplicate key and CP handle including two coats of spray painting over a coat or red oxide primer complete fixed in existing cupboard fixed with necessary nuts, bolts including embedded in PCC 1:2:4 (area of opening shall be measured) complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm with and including pedestal white, fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest and PVC (SWR) 'P' or 'S' trap of pressure rating 6 Kg/ sqcm complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F sinks with drainage board made out of stainless steel 1mm thick sheet for kitchen with plugs, waste pipe, brass chromium plated coupling and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm as in repair complete all as specified and as directed by the Engineer-in-Charge
S&F kitchen plate rack of stainless steel sheet 1mm thickness size 900mm x 900mm x250mm and having weight not less than 8.00 Kg each as in repair complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases to brick wall ,pinning in making good to facing where required and pointing in CM 1:3 to ends or edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 20mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore fancy type cast copper alloy chromium plated stop valves with long shank and cup (concealed type), screwed down, high pressure with crutch handle, scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm bore fancy type brass chromium plated with long body and crutch handle screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 600 mm as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type pillar tap of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement as in repair complete all as specified and as directed by the Engineer-in-Charge
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 mm wide with chromiun plated brackets guard and railing 60 cm long as in reapir complete all as specified and as direced by the Engineer-in-charge.
S & F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor or fixed to wall as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor or fixed to wall as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) juction single (Single T) equal are unequal with access door as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC (SWR) juction single (Single T) equal are unequal with access door as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F 100mm bore PVC (SWR) vent cowl etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix stack clamp out of 50mm x5mm flat iron 16mm dia round iron stays including bolt and nuts and securing ends of stays to walls or roof for 75mm bore pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with crutch or butterfly handle, scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with crutch or butterfly handle, scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shall be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
M & L providing PCC precast 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, precast cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weathering, throating etc and setting in CM 1:4 complete with joints to match, complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel curtain rod 25mm dia having wall thickness 1.6mm fixed with and including stainless steel decorative brackets, two lotto for each road length at both end etc complete all as specified and as directed by the Engineer-in-Charge.
Surface excavation not exceeding 30cm deep and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc 63mm , deposited , spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M&L machine pressed rubber moulded coloured precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006, ISI marked of 60 mm thickness, grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge.
M & L applying a coat of solar reflective aluminium paint @ 0.11 kg per sqm on APP membrane surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L providing cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings including necessary form works, weathering slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
Removing of excavated material to a distance not exc 50 m and depositing at a level not exc 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing old decorated/undecorated plastered surfaces and applying two coats of oil bound distemper with painting roller over and including 1 to 2 mm thick wall care putty white cement based in two or more coats to achive smooth surfaces complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy fancy type chromium plated angular stop valves screwed down, high pressure with crutch handle, scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated toilet paper holder complete fixed to wall as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing plastic water closet seat cover , white closed pattern with recessed bottom, and cover and mild steel chromium plated or aluminised hinging device as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC cabinet type looking mirror size 450 mm x 600 mm box type including all as necessary items as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair brass chromium plated wall/sink mixer for mixing hot & cold water for 15mm bore pipes with hand shower arrangement including all connecting fittings, screwed down for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair brass chromium palted WHB mixer for mixing hot & cold water for 15mm bore pipes including all connecting fittings, screwed down for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws as in repair complete all as specified and as directed by the Engineer-in-Charge
S&F brass chromium plated overhead shower 200mmx200mm square shape single flow ABS body chrome plated with grey face plate with rubit clean system as in repair complete all as specified and directed by Engr-in-Charge.
S & F brass CP Towel ring round between flanges including fixing with brass screws complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ACN-1121BN/Cera Cat Part No.F5007105 / Hindware Cat Part No.F 880007
S & F brass CP corner glass slelf (with bracket) including fixing with brass screws to wall complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ACN-1173/Cera Cat Part No.F5005101 / Hindware Cat Part No.F 890009
Supply and fix double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, govering pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 12 mm thick prelaminated particale board,interior grade, prelaminated both side with decorative choice lamination and fixed to aluminium door with glazing clips, rubber gasket etc complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated aluminium section (minimum thickness of powder coating 50 micron) for doors,windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws complete all as specified and as directed by the Engineer-in-Charge. Note : (a). Glazing shall be measured and paid separately; (b). Weight of aluminium sections shall be as per IS or actual weight which ever less shall be measured. (c). The rates quoted shall be inclusive of neoprene beading, glazing clips, jointing clips, screws, etc as required and the same shall not be measured for arriving the weight; (d). The rates shall be inclusive of locking arrangement including complete packing with silicon gel alround contacting surface of aluminium framework and including matching the existing surface area complete all as specified and directed.
Supply and fixing 4.8 mm thick tinted glass to aluminium door with glazing clips, rubber gasket etc complete all as specified and as directed by the Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge.
S & F 500 Litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed by the Engineer-in-Charge. Note:- Tank shall be in white colour.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:4:8 Type D-1 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L Non Skid coloured ceramic tiles premium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 15mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fiber pulp, insulation etc) or insulation boards/ slabs/blankets any thickness including cover fillets and false ceiling frame /gird of any type/any description, fixed in position,complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing false ceiling with semi perforated 12 mm thick micro tegular edged at all hights with GRG(glass fiber reinforced gypsum ) false ceiling tiles of size 595mmx595mm of approved texture ,design and pattern having moisture content less than 2% ,humidity resistance of 99% ,NRC 0.5 to 0.75 as per IS 8225-1987 ,non- combustile as per BS475 (part-4) -1970 and light code description unit rate No.429 SUB HEAD :26.0 new technologies and material reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 gms per sqm including both sides ) comprising of main -T runners of size 15x32mm of length 3000mm ,cross T of size 15x32mm of length 1200mm and secondry intermediate cross-T of size 15x32mm of length 600 mm to form grid module of size 600x600mm ,suspended from ceiling using galvanised mild steel items (galvanising @80 gms per sqm ) i.e, 50mm long ,8 mm outer diameter M-6 dash fastners ,6mm dia fully threaded hanger rod upto 1000mm length and L- Shape level adjuster of size 85x25x2mm . Galvanised iron perimeter wall angle of size 24x24x0.4mm of length 3000mm to be fixed on periphery wall /partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws . complete all as specified and as directed by the Engineer-in-Charge.
S & F bib tap 15mm dia brass chromium plated fancy type with crutch handle screwed down for iron pipe and fixed complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make :Jaquar Cat Part No : QQP-7037PM / Cera Cat Part No.F1003151 / Hindware Cat Part No.F 330041
S & F CP Brass wash hand basin mixer for mixing hot and cold water screwed down for 15mm dia pipe including waste popup waste with 450mm long braided hoses and all connecting fittings complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charg Make :Jaquar Cat Part No QQP-7167BPM / Cera Cat Part No.F2007461 / Hindware Cat Part No.F 480011
S & F CP brass wall mixture 3-in-1 system with provision for both hand shower and overhead shower complete with 115 mm long bend pipe , connecting legs & wall flange without hand & overhead shower as in repair complete all as specified and as directed by the Engineer-in-Charg Make :Jaquar Cat Part No QQT-7309 /Hindware Cat Part No.F 120019
M & L 75mm bore PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated tublar towel rail, 20mm dia, D type 60cm long between flanges complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No: ACN-1101S/Cera Cat Part No.F5002103
S & F 15mm bore angular valves, fancy type brass chromium plated with long shank and cup (Concealed) type complete fixed as in rtepair complete all as specified and as directed by the Engineer-in-Charge. Make :Jaquar : Cat Part- QQP-7053PM / Cera Cat Part No.1003201 / Hindware Cat Part No.F 370006
S & F brass CP toilet paper holder including fixing with brass screws to wall complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : AKP-35753PS/Cera Cat Part No.F5007109 / Hindware Cat Part No.F 840009
S&F brass chromium plated shower rose 100mm dia with or without swivel joint with arm of standard size as per site as in repair complete all as specified and as direced by the Engineer-in-charge.
S & F glass slelf (with bracket) including fixing with brass screws to wall complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ACN-1171N/Cera Cat Part No.F5005301/ Hindware Cat Part No.F 840011
S & F single pieace water closet wtih PP soft close seat cover, hinges, fixing accessories and accessories set, cistern fittings S or P Trap complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No SLS -WHT-6855S / /CERA Cat part No.S10131095 /Hindware Cat Part No.92099 (S-30)
S&F 32 mm dia PVC waste pipe of standard length for wash hand basin / Kitchen sink etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated hand shower ( health faucut) with 8 mm dia 1.2 mtr long flexible tube and wall hook with NRV ( back flow preventor )complete fixed to wall complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ALD577/Cera Cat Part No. F8030101
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm as in repair complete all as specified and as directed by the Engineer-in-Charge.
M & L 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
S & F continuous (paino) hinges , width of flaps 30mm (when open) mild steel bright finish or electro galvanished complete all as specified and as directed by the Engr-in-charge.
S&F 100 mm long fancy type stainless steel handle complete all as specified and as directed by the Engineer-in-Charge.
S&F magnet catcher fixed in cabnet shutter (one portion) and wooden frame (other portion) with screw complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 100 mm size mild steel mortice lock, vertical type, 2 levers with duplicate key complete all as specified and as directed by the Engineer-in-Charge.
S&F aluminium (Diecast) body hydraulically door closer regulated,designation No.3, universal type,suitable for door shutters of 851 mm to 1000 mm in width and weight between 61 to 80 Kg complete all as specified and as directed by the Engr-in-charge.
S&F 5 to 6mm thick mirror including ingraved any pattern, with wooden beading of any size fixed to wall with chromium plated brass screws and cup washers and all connected fitting complete all as specified and as directed by the Engr-in-charge.
Dismantling plain or corrugated steel sheeting, any gauge, thickness in roof coverings including ridges complete all as specified and as directed by the Engineer-in-Charge.
Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and as directed by the Engineer-in-Charge.
M&L 6mm thick asbestos cement, corrugated or semi- corrugated in roofs,walls etc fixed with L type or J type or cranked hook bolts complete all as specified and as directed by Engr-in -charge.
Dismantling wooden scantling of any description not otherwise provided for complete all as specified and as directed by the Engineer-in-Charge.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade E-250) quality B complete all as specified and as directed by the Engineer-in-Charge
S & F vitreous china table top wash hand basin white, of size 565mmx420mmx140mm fixed on and including 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F brass CP Single towel rack 600 mm long between flanges including brackets complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ACN-1181FHS/Cera Cat Part No. F5007101 / Hindware Cat Part No.F 890012
Brass CP SOAP DISH HOLDER including fixing with brass screws to wall complete fixed as in repair complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No : ACN-1131N/Cera Cat Part No.F500716 / Hindware Cat Part No.F 840006
M&L 16 to 18 mm thick prelaminated MDF board exterier grade (grade-1) confirming IS 14587, fixed with nails for kitchen cupboard and cabinet ,shelves for cupboard including 3mm thick 2nd class hardwood leeping patti on cut edge of boards as in repair complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on wall by scrappers or any other means and washing , rubbing down with water to remove loose particlse etc and applying two coats of oil bound distemper with painting roller over and including 1 to 2 mm thick wall care putty white cement based in two or more coats to achive smooth surfaces complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases to brick wall ,pinning in making good to facing where required and pointing in CM 1:3 to ends or edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting exceeding 20 cm girth complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete 1:1-1/2:3 (Nominal Mix) using 20mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M&L TMT mild steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 5mm dia and over up to and including 10mm dia in stirrups, spacers etc, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 gm per sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S&F 12 mm thick costomized and moulded toughened glass as in partition, door, fixed with patch fittings of stainless steel grade 304 or any suitable fittings of stainless steel grade 304 as required (fixing of glass should be top to bottom and any cutting required shall be done with diamond blade) including drilling holes for patch fittings and spider fittings as required and locking arrangement complete all as specified and directed by Engr-in -charge
Supply and fixing 25 to 30mm stainless steel channel of grade 304 in floor including cutting in any floor finish and embedding the channel for receving the glass including silicon filling etc complete all as specified and directed by Engr-in -charge
Supply and fixing 25 to 30mm stainless steel channel of grade 304 as in top to fix or hanging glass as in top including suspending to channel to hang glass as in partition complete all as specified and directed by Engr-in -charge
Supply and fixing 25 to 30mm stainless steel channel of grade 304 , fixed along wall with patch fittings of stainless steel to receive glass complete all as specified and directed by Engr-in -charge
M and L precast cement concrete 1:2:4 type B0 using 12.5mm curshed stone aggregate louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (Pre cast frame shall be measured separately and paid for under item) and set in cm 1:4 complete all as specified and directed by Engr-in -charge.
M & L precast cement concrete 1:2:4 type B-1 using 20 mm curshed stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 with joints to match complete all as specified and directed by Engr-in -charge.
M & L mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates of Fe-410-W(Gde E-250) quality-B complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'A' Part-II (E/M itmes) Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 156 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 156 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring with 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 2/3 pin combined, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 3/3 pin combined, (6pin), 6/16amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F of electronic Fan regulator modular 120 watt, 2 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
S&F modular bell push 6 Amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply & fix calling bell ding dong 230 volt including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
S&F LED lamp 12 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down unserviceable bulbs complete all as specified and as directed by the Engineer-in-Charge.
S&F LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down unserviceable bulbs complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing indoor decorative LED tube light fitting box type 1x18/20 watt with opal diffuser, high efficient aluminium housing body in CRCA body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 1x18/20 watt LED tube rod luminaries (Warm/Cool as per site requirement) environment friendly, high efficient, T8 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair mirror light 9/12watt LED wall mounting fixture, one feet , aluminium housing compact & energy efficient epoxy powder coated CRCA light luminaire, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing unserviceable items all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, auminum housing, surge protection including driver & LED lamp etc complete with all accessories connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F LED 22 watt integrated batten with inbuilt lithium ion battery with minimum 4 hour back up including removing of unservicable light fitting complete all as specified and as directed by the Engineer-in-Charge.
S&F LED lamp Invertor technology 9 watt with 4 hour power back up with efficiency more than 100 lumen per watt,Lithium ion battery including removing of unservicable lamp complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP, 6-32 Amps, 240 volt,10 KA , 'C' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN, 40 Amps, 240 volt,10 KA , 'C' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix RCBO 40 Amps, 2 pole, 2 Module, 300 mA, (HI immunity) sensitivity, 230 volts, 50 Hz, including removing old unserviceable RCBO complete all as specified and as directed by the Engr-in-charge.
Supply and fix RCBO 40 Amps, 2 pole, 2 Module, 100 mA, (HI immunity) sensitivity, 230 volts, 50 Hz, including removing old unserviceable RCBO complete all as specified and as directed by the Engr-in-charge.
Supply and fix as in repair over and Low voltage release 1 module, 230 volts AC, suitable for single phase adjustabe from 170 volts to 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fixing LED flat panel 2' x 2' size fully difused surface/ recess mounted fitting (grid/ gypsum type) 36-40 watt , 5700K, warm/cool white with powder coating and CRCA front cover including frame with provision of PVC flexible copper conductor cable to light fitting as in repair complete all as specified and as directed by the Engr-in-charge.
Supply and fixing LED batten fitting 10-12 watt, 2 feet, aluminium housing and electronic driver including tube rod 10/12 watt cool/warm type industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Disconnecting electrical connection and anchor fastner, taking down existing water storage heater of any capacity and refixing the same in original position complete all as specified and as directed by the Engr-in-charge. Note:-The quoted rates shall be deemed to be included of anchor fastners, electrical connection, testing and minor work required at site.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 20mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors with insulators per 0.5 meter on the wall & above ground complete all as specified and as directed by Engineer-in-Charge.
S & F galvanised iron strip 32 x 6mm buried in ground complete all as specified and as directed by Engineer-in-Charge.
S & F air termination, single pointed copper rod 12 mm dia and 300mm long with insulators as suitable complete all as specified and as directed by Engineer-in-Charge.
M & L test point terminal block made of gun metal of size 75 x 75x 25 mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screw complete all as specified and as directed by Engineer-in-Charge.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old U/S fitting complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable 70 sqmm cross sectional area, 3.5 core with aluminium conductor, 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables, GI pipes and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L dry sand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 50mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directed by Engineer-in-Charge
S&F MCCB 4 pole , 125 Amp, 415 Volts, 35 KA , with and including double door enclosure made out from 2mm thick MS sheet duly painted with two coats of synthetic enamal paint over a coat red oxide primer with locking arrangment and fixed on wall complete all as specified and as directed by the Engr-in-charge.
Supply and fix wall mounting fan, 400mm sweep, off white colour, AC single phase 230 volts, 1300 RPM, and fixed on wall with necessary nuts, bolts & washers including grouting bolts in wall and making nacessary electrical connection complete all as specified and as directed by the Engr-in-charge.
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard, copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades and applying one coat of painting on ceiling fans with synthetic enamel paint by spraying incl filling cavaties with filler after cleaning all dust etc, reassembling the same and refixing in original location including making connection with 3 core copper cable complete all as specified and as directed by the Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing as in repair complete all as directed by Engineer-in-Charge and earth testing on completion .
M & L for earthing complete with Copper earth plate electrode 600 x 600 cm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to copper strip size 20x 3mm as earthing lead by means of bolts, nuts, check nuts and washers of copper and earth strip protected by 40mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
M & L galvanised iron tubing 50mm bore medium grade with all fittings and laid in trenches or fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 40mm bore medium grade with all fittings and laid in trenches or fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
M & L cutting 150 mm bore cast iron pipes in position for insertion of new tees, branchess etc complete all as specified and as directed by the Engineer-in-Charge.
M & L cast iron fittings up to 150mm bore pipe such as bends, tapers, tee pieces (single & double branch) any type and angle/radius and straight connecting pieces complete all as specified and as directed by the Engineer-in-Charge.
S & F 50 mm bore Gun-metal, globe or gate valves with iron wheel head screwed class-I with one sockets, nipple and union sockets screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 40 mm bore Gun-metal, globe or gate valves with iron wheel head screwed class-I with one sockets, nipple and union sockets screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
M & L 2000 Litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge. Note:- Tank shall be in white colour.
S & F 25 mm dia ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
M & L rolled mild steel work in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 410-W (Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
M & L valve chamber/pit of internal size 450mm x 450mm x 450mm depth with one brick thick masonary wall built in CM 1:4, 100mm thick PCC 1:3:6 in foundation extended 15cm from the outer edge of brick wall all round, 15mm thick plaster in cm 1:4 on internal/external surfaces of brick work including MS sheet cover 3mm thick along with angle iron frame of size 40 x 40x 6 mm with locking arrangment & necessary fixing materials like hinges, nut/ bolts etc and painting to MS work with one coat of red oxide and two coats of synthetic enamel paint and necessary excavation & earth work complete all as specified and as directed by the Engineer-in-Charge.
M/s Vridhi Construction Co.
V K Constructive Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .