Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹33.4 L+₹6.5 L (24.3%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L2 | Rejected-Finance 3RD LOWEST BIDDER | |
| 3 | L3₹42.8 L+₹15.9 L (59.1%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance 2ND LOWEST BIDDER | |
| 4 | Rejected-Technical 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | - | Rejected-Technical 1. Authorization Certificate is incomplete as per condition of the tender clause no. 5(i) 2. Electrical contractor License not found as per notice clause no. 3 (iii) |
Tender Value
Refer Docs
EMD Value
₹84,138
Closing Date
15 Jun 2021, 2:00 pmClosed
Office of SE,SWEC,PWD, MIDNAPORE
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Construction of (G plus 4) District Judge Court building within the campus of District Judge court in the district of Purulia--Supply, Installation, Testing and Commissioning of Fire Detection and Annunciation system.
2021_WBPWD_326888_2
WBPWD/SE/SWEC/NIQ40/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
PURULIA
Please refer Tender documents.
4 documents required · 4 mandatory
₹84,138
Office of SE / SWEC, PWD, Midnapore
20 Jul 2022
29 May 2021
17 Jun 2021
29 May 2021
15 Jun 2021
3 Jun 2021
2 Jun 2021
Amount
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent optical -Thermal multi-criteria detector, Deatiled specification given in Annexure-A .(Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST).
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (MCP).Deatiled specification given in Annexure-A (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST).
Supply, Installation, Testing & Commissioning of Addressable sounders/ stobers/Hooters .Deatiled specification given in Annexure-A . (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST)
Supply, Installation, Testing & Commissioning of Addressable Transponder and Control /Monitor Modules for monitoring flow switches/Fire exit doors /Lift / AHU etc complete as required.Deatiled specification given in Annexure-A (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST)
Supply, Installation, Testing & Commissioning of Microprocessor based Intelligent Addressable Fire Alarm control Panel .(FACP) having expandable and fully networkable features suitable for handling all the detectors and devices for this project. It can be suitably configured according to the OEM loop capacity, Deatiled specification given in Annexure-A . (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST).
Supply, Installation, Testing & Commissioning of LED type Response Indicator.Deatiled specification given in Annexure-A (Approved make : Honeywell/ Siemens / Secutron/ Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton/GST).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / RR Kabel/ Polycab) with 20mm NB PVC rigid conduit pipe on the surface of the wall. (Make : Precission-Medium).Deatiled given in Annexure-A.
Supply, Installation, Testing & commissioning of of 7AH - 12 Volt DC battery for standby power supply system for Main FACP, (Make: Exide\Amaron/APC).Deatiled given in Annexure-A.
NOTE :1.The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.3. As built drawing shall be submitted in Both soft (CAD) & hard copy format..Drawing shall be approved by the Engineer in charge before the commence of the work. 4. Necessary Certificate from the Competent Authority / Statutory body should be obtained by the executing agency if asked by EIC 5. The work shall be completed in all respect and shall be free from all kinds of defects/deficiencies/damages in equipment, materials, components and other auxiliaries and workmanship from any cause whatsoever for a period of Three years warrenty or, total replacement in case of major defects or fault for both the FACP and the battery. 6.Test Certificates of individual components may be produced if asked by EIC
GLYPTIC
TAPAN KUMAR SARKAR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .