Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹7.6 L
EMD Value
₹8,000
Closing Date
5 Dec 2026, 4:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
The Deputy Executive Engineer Electrical R and B Sub Division PWD Campus Panvadi Bhavnagar
PROVIDING & ERECTING SOLAR ROOFTOP PLANT AT SIR P.P. INSTITUTE OF SCIENCE COLLEGE, UNIVERSITY CAMPUS -BHAVNAGAR,TA. & DIST.:- BHAVNAGAR.
367970
E Tender 14 of 2026-27
Open
Electrical Works
Works
Bhavnagar
1 document required · 1 mandatory
₹900
The Executive Engineer, Electrical R&B Division, Bhavnagar
₹8,000
21 Nov 2026
21 Nov 2026
21 Nov 2026
5 Dec 2026
21 Nov 2026
90 days
OF PROVIDING & ERECTING SOLAR ROOFTOP PLANT AT SIR P.P. INSTITUTE OF SCIENCE COLLEGE, UNIVERSITY CAMPUS -
WORK: BHAVNAGAR,TA. & DIST.:- BHAVNAGAR.
SR NO ITEM QTY. UNIT IN WORDS Amout
1 Supply, Installation, Testing & Commissioning of following size of Grid Tied 18 PER KW 42455.35 Rupees Forty Two
Solar Power Plant with Thousand Four
Solar Panels (ALMM approved): Frame Material : Anodized Aluminum alloy Hundred Fifty Five
Frame With Twin Wall Profile, Front Cover : High Transmission Low-Iron And Paise Thirty
Tempered Glass (AR Coated), High efficency and positive power tolerance Five Only
Pmax: 0/+5, Module Efficiency should be approx. 19.5%-22%, Normal
operating temperature 45'C, Junction Box with Waterproof IP67 & MC4
Compatible and Enclosed with Bypass diodes, 100% Electroluminescence
test to ensure error free Modules, Thep. temp. co-efficient of the PV module
shall equal or better than -0.45%/degree C. Solar PV modules of minimum fill
factor 75% to be used. Unit Production:- More than 4.5 Unit /kw /day
(Actual)(1Year Avg) With 10 year Product warranty. Modules must be
complied to the DCR(Domestic content requirements). The Ration of AC to
DC is 5:6 for the Installation capacity which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency:
97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p
Power Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -25~60°C,
Integrated protection of Inverter are Anti-islanding Protection, Input Reverse
Polarity Protection, Insulation Resistor Detection, Ground fault protection,
Residual Current Monitoring Unit, Output Over Current Protection, Output
Short Circuit Protection, Output Over Voltage Protection, PV array string fault
Protection. Protection Degree: IP65, User Interface LCD & APP, Datalogger &
Communication: GPRS / Wi-Fi.
0 Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor
Detection Integrated, Residual Current Monitoring Unit Integrated, Output
Over Current Protection Integrated, Output Short Circuit Protection Integrated,
Output Over Voltage Protection Integrated, Protection Degree: IP65, User
Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi, Module
Mounting Structure: The mounting (Rectangular pipe / square pipe / circular
pipe) with requisite cross bars, nuts and bolts, etc. shall be Hot deep
galvanized with minimum 80micron coating. The Rectangular / square
/circular hollow pipe section used for the structure should have a minimum
thickness of 2.0 mm. other than above, the material thickness should be
minimum 2.5 mm. A certificate of a structural engineer certifying the strength
and stability of the mounting structure to withstand the weight and wind speed
of 150 km/hour , shall be submitted by the vendors. Hot Dipped Galvanized
steel coils. suitable arrangement for base plate for foundation , solar panel
mounting, the structure should be suitable for carry the load of solar
panel,wiring, sprinkler system etc. with necessary foundation work/wall
mount, j bolt, anchor fastner etc. the nut bolt used for installtion of stucture
should be (SS 304) quality.The ground clearance of the bottom most edge of
solar panel shall not be less than 300 mm to 1200 mm or as per site’s
technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM Balane
of System with necessary Swichgears (Suitabel size and protection of ACDB
& DCDB), inter connecting wiring, earthing system as per the CEIG drawing
approval, lightining arrester system as per the CEIG drawing approval, all
liasoning work with various gov. dipartment like state nodal agency,DISCOM
& CEIG is included in agency scope (Excluding All charges namely GEDA
Application fees, Solar connectivity Charges, Meter connectivity Charges,
Meter testing Charges and system stability/strenthning charges.) (C ) Grid
Tied Solar Power System: 11 - 25 kW (3 - phase)
AMOUNT PUT TO TENDER FOR RS.
Rupees Seven Lakh(s) Sixty Four Thousand One Hundred Ninety Six And Paise Thirty Only
(A) Total Tendered Amount Rs..…..……………….…………...…………….
(B) Rebate on above tendered amount (if any)………………..…..%(in Figure) Rs….………………….………………………...
(C) Net tendered amount (A-B) Rs……………………………………………….
All work shall be carried out as per Public Works Department Handbook and other specification of Division or as directed
Rates quoted include clearance of site (prior commencement of work and at its close) in all respects and hold good for work under all
conditions, site, moisture, weather etc.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Additional Instruction (3).pdf
Eligibility Criteria for solar work (1) (2).pdf
nivida-14.pdf
general condition and performa Amreli (3).pdf
SBD SIR PP.pdf
SCH-A SIR PP.pdf
SCH-B SIR PP.pdf
tender details SOLAR SIR PP.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .