Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance SARCH GANDERBAL J K 191131 | GANDERBAL | JAMMU AND KASHMIR | 191131 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
19 Jan 2023, 4:00 pmClosed
EXECUTIVE ENGINEER RNB SRINAGAR
EXECUTIVE ENGINEER RNB SRINAGAR
Electrification of Block at transit accommodations Block no.04, 16 flats at wandhama Ganderbal
2023_PWDJK_202434_4
E/NIT/169/2023/24dtd13/01/2023
Open Tender
Electrical Works
Item Rate
wandhama
AS PER BOQ
2 documents required · 2 mandatory
₹600
EXECUTIVE ENGINEER RNB SRINAGAR
₹25,000
Yes
19 Jan 2023
14 Jan 2023
19 Jan 2023
14 Jan 2023
19 Jan 2023
14 Jan 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of srandard make dully isi marked, to be laid in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box etc. as required (excluding cost of conduit) but including cost of circuit wiring from DB to first switch in sub circuit.complete job
Providing of Wiring for Power plug points (16 Amps socket outlet points) with 3X4 sq. mm FRLS PVC insulated copper conductor single core cable of srandard make dully isi marked to be laid in surface/ recessed PVC conduit along as required with making of necessary connections (excl cost of Conduit ) but including cost of circuit wiring from DB to first switch in sub circuit complete job
providing and laying of Wiring for 6 Amp Socket Out Points with 3X2.5 sq. mm FRLS PVC insulated copper conductor single core cable of srandard make dully isi marked,to be laid in surface/ recessed PVC conduit , including making of necessary connections (excl cost of Conduit ) but including cost of circuit wiring from DB to first switch in sub circuit.complete job
Providing and laying of Wiring for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable of srandard make dully isi marked to be laid in surface/ recessed medium class PVC conduit as required
2 X 16 sq. mm + 1 X 16 sq. mm earth wire
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 in 5/6 A modular socket outlet and 5/6 A modular switch. connections etc. as required
Supply and Fixing of two module stepped type Electronic Fan regulatot on the existing modular plate switch box including connections etc as required.
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections. testing and commissioning etc. as required
Single Pole
Supplying and fixing 40-63 Amp 240/415V, 10 kA. "C" curve. miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A
Supplying and fixing 32 Amp 240/415V. 2 Module Change over Switch fitted in exciting D Box incl making of necessary connections
Supply and Fixing of Neon Indicator Modular Switch Series incl its Frame Plate, cover plate and G I Box of required size
Suppling and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply of 15 Watt Surface mounted Slim / Recessed tve LED Fixtures of Standard make dully ISI marked.
Supply of 14 Watt Batten Type Al Base LED Light Fixture of standard make as mirror lights of Standard make dully ISI marked
Supolv of 1400 mm sweep Ceiling Fans complete in all respects.
Supplv of 250 mm sweep Shutter type Exhaust Fans comolete.
Supply of 30 watt LED (IP67) street Light made of pressure die cast Aluminum Housing with high power LEDs, Lens & Toughened alass IP66 fitted on ornemental L Bracket Complete
Supply of AC / DC Bells with its Batteries.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
Upto 450 sweep
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required for repairs or laying of additional conduits wherever required
Design, Fabrication, assembly, Installation, Testing and Commissioning of Front Operated Cubicle type compartmentalised as per form 3B free standing, dust and verim proof (IP 42 ingress protection) LT panel suitable for use of 415 volts, 3 Phase 4 wire 50Hz suitable for a fault levewl of 55kA at 415 volts, fabricated from 2 mm thick Powder coated paint finish of approved shade CRCA MS sheet with hinged, gasketted9 metal based neoprene) and lockable doors having structral reinforcement with suitable angle/ chanel/T / Flat section uncl gland plates as requiredand lifting hooks with sleeved TPN AL Busbars and G I strip of required size with 2 no earthing terminals complete with interconnections as required for MCB's and control wiring. Each incoming / out going breakers shall have thermal megeatic release. The panel will be made as oper detailed specifications and drawings formating part of this document. Incomer:- 1 No 400 Amp TPN MCCB with beaking capacity 50 kA with thermal release and adjustable settings. 1 Set of R,Y,B Phase indicating lamps 1 No MFM with 630/5CT coils 1 Set of 500 Amp TPN Alluminum Bus Bar with colour coding sleeves Out Going :- 16 No 100 Amp D Pole MCB's 6 No 32-40 Amp D P MCB's 2 no 63 Amp TPN MCB
Supply, laying, jointing, terminating, testing and commissioning of 185 sq mm 3.5 Core 1100 V grade, armoured, PVC/ XLPE, aluminum(AL) conductor cables of ISI Make on existing trays/walls/columns/ trenches including the cost of supports with suitable clamps, saddles, hooks, bolts etc. and including the cost of proper dressing of cables, markers providing identification tags, earthing of glands armouring etc complete.
Chemical Earthing with 3 mts long I electrode to 50 mm dia G I Pipe placed verticaly in 100 mm dia bore dully drilled with hand drill and filed with required quantatity of chemical and man hole cover at top. The job includes extending of Earthing fron Eart Electrode to Main L T panel with 19 x5 mm G I Strip in one run
M/S BHAT ENGINEERING
M/S FAROOQ AHMAD BHAT
X TREME ENGINEERS
M/S S.S. TRADERS
M/S PEARL ENTERPRISES
stage.html
html • 0.03 MB
finance_541086.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .