| 1 | L1₹10.7 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC M/s Krishna Construction Company is the Lowest Bidder, hence accepted | |
| 2 | L2₹11.3 L+₹18,266 (1.64%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹12.6 L+₹1.5 L (13.1%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
13 Nov 2023, 6:00 pmClosed
Garrison Engineer
GE (AF) Phalodi
Repair to flooring, Path, External surface, replacement of fencing, steel doors in WSA complex and associated E/M works at AF Stn Phalodi
2023_MES_623282_1
8513/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Phalodi
Class E Category a(i)
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹30,000
Yes
11 Jan 2024
14 Oct 2023
20 Nov 2023
14 Oct 2023
13 Nov 2023
29 Oct 2023
Amount
Demolition of cement concrete (unreinforced) of any description not other specifically provided for etc complete all as specified and directed.
Taking down cement plaster or any description including raking out joints, hacking for key, scrubbing down with water etc and removal of debris to a distance not exc 50 mts and depositing where directed complete all as specified and directed..
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for 75 mm thick plain cement concrete (1:3:6), type C1, using 20 mm graded stone aggregate as in plinth protection, path etc laid in alternate bays not exc 3 m in length, and finishing cement concrete surface even and smooth without using extra cement all as specified and directed.
M&L for 75mm thick Cement concrete type D-2, (1:4:8) using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for 40 mm thick plain cement concrete (1:2:4) type B-0 using 12.5mm graded aggregate as in floor including finishing top cement concrete surface even & smooth without using extra cement all as specified and directed.
M&L for 3 mm thick glass dividing strips of 38 mm width inserted in position complete all as specified and directed.
M&L for 10 mm thick rendering in CM (1:6) on other than fair faces of brick work or concrete surfaces including finishing plaster surface even and smooth without using extra cement all as specified and directed.
M&L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed
M&L for preparation of old distempered surfaces of walls by washing, rubbing down and stopping of distempered and painted surfaces and treating oil and greasy spots and applying one coat of oil bound distemper oil emulsion white or tinted complete all as specified and directed.
Dismantling of AC (corrugated or semi corrugated etc) sheets in roof covering complete all as specified and directed.
S&F 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in roof, wall etc.complete all as specified and directed.
M&L for 10 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for glazed coloured ceramic tiles 300x200x7 mm thick, on vertical surfaces of wall such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick backing coat in CM (1:3) complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with pigment to match the shade of the slab including rubbing and polishing including screed bed and bedding layer of mortar 20 mm thick in CM (1:4) for laying floor finishes size complete all as specified and directed.
M&L for cleaning and removing all scale and dirt etc from tank exc 250 litre but not exc 500 litre capacity of any type (AC, RCC or PVC) and cleaning mouths of circulating pipes etc and writing date of cleaning on tank using enamel paint complete all as specified and directed. Note :- (a). The size and pattern of letters of date shall be as per format approved by Engineer in charge. (b). The unit quoted rate deemed to be included of cost of bleaching powder or any other cleaning agent to be used for tank cleaning.
M&L for cleaning and removing all scale and dirt etc from tank exc 500 litre but not exc 1000 litre capacity of any type (AC, RCC or PVC) and cleaning mouths of circulating pipes etc and writing date of cleaning on tank using enamel paint complete all as specified and directed. Note :- (a). The size and pattern of letters of date shall be as per format approved by Engineer in charge. (b). The unit quoted rate deemed to be included of cost of bleaching powder or any other cleaning agent to be used for tank cleaning.
Dewatering of residual water, disilting and mud Cleaning of SWT of capacity 50000 Ltr as described below :- (a) The inner surface of the wall of tank shall be cleaned with high pressure jet pump after emptying the water in the tank. (b) After through cleaning of the Tank, the cleaning water and the cleaning water and sludge is to be removed by using pump and sludge has to be disposed off at a place as directed. (c) After made the Tank dirt free, the inner surface of Tank shall be treated with approved anti bacterial agents by GE. (d) After the treatment as mentioned at (c) above , the inner surface of the Tank shall be treated with UV-Radiator. (e) Writing date of cleaning on tank using synthetic enamel paint with letters n. exc 30 cm high complete all as specified and directed. (f) Removal of any tiny plants and vegetation any position and necessary repair work of SWTs. Note :- (a) The size and pattern of letters of date shall be as per format approved by GE and will be paid under respective item of BOQ. (b) The unit rate quoted deemed to be included of cost of bleaching powder or any other cleaning agent to be used for tank cleaning. (c) Cost of Earthwork and excavation at places deemed to be included in unit quoted rate.
M&L for preparing old painted plastered surface of walls by washing, rubbing down & stopping and applying one coat of exterior emulsion paint of 1st grade quality, in one or more tints and pattern (camouflage) as approved complete all as specified and directed.
M&L for 15mm thick plaster in two layer on external surfaces :- 1 layer 10mm thick in CM (1:4) & 2nd layer 5mm thick in CM (1:4) on fair faces of concrete or masonary surfaces with water proofing compound @ 3% by weight of cement on concrete or masonary surfaces and finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid for seperately as supply only under respective item. No extra cost will be pay for all jams, chajjas, projection, etc
Supply only integral water proofing compound conforming to relevant IS complete all as specified and directed.
M&L for preparing on newly plastered wall surfaces and finishing walls with Acrylic Smooth exterior paint in one or more tints and pattern (camouflage) as approved of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
M&L for anodised aluminium snap grid 605x605mm frame work for false ceiling using main tee of size 25x35x1.50mm & cross tee of size 25x35x1.50mm, aluminium anodized angle section 25x25x1.50mm supported hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to RCC roof slabs/iron truss by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including 12mm thick gypsum board/tiles for insulation and acoustic purpose of size 600mmx600mm fixed with screws with staple on snap grid as per manufacturers instructions etc complete all as specified and directed.
Dismantling of structural steel work including door gates but excluding framed truss complete all as specified and directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Gde E-250, quality A complete all as specified and directed.
Dismantling chain link fencing of any guage & size not exc 4 Kg/Sqm complete all as specified and as directed
Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
M&L for Running welding thickness of metal to be welded exc 6mm but n exc 9mm complete all as specified and directed.
Demolition of Brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for Pre-cast cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate in block masonry with solid blocks, exc. 10 cm in width and setting in Cement mortar (1:6), complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement, including forms, moulds, mitered/stopped end etc. complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S&F 3.00 mm thick sheet glass,ordinary quality and glazing with oil putty in squares not exceeding 0.50 sq.m. in each pane complete all as specified and directed. Note : The work will be executed at G+3 storey.
M&L for preparation of new steel surfaces of any description not otherwise described not exc 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide primer complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out for laying underground cable in soft/losse soil complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for laying underground cable in hard/dense soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
M&L for dry tibba sand in trenches for cushioning to under ground cable spreading, levelling, hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Disconnecting and Taking out of old LT armored PVC cables of any size/core/any voltage grade from trenches for replacement complete all as specified and directed.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2.0 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
M&L for cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line and finished surfaces by extracted material and provided with 150mm thick PCC (1:3:6) type C-2 as top layer to match the existing surfaces and remove surplus extracted material 50 m away complete all as specified and directed.
S&F 50 mm bore tube, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for making of surface for painting duly scrubing the existing paint and applying two coats of synthetic enamel paint over a coat of red oxide primer for LT panel board/Feeder piller box of any size/type at various location complete all as specified and directed.
M&L for servicing to Outdoor/Indoor type LT panel Board of any capacity/size by replacing pitted portion area not exceeding 1.0 sqm with suitable gauge of MS sheet,welding work,replacement of unservicable door hinges and locking arrangement complete all as specified and directed.
S&F in repair Adjustable thermal & Adjuatable magnetic setting MCCB four pole 63 Amps, 16 KA rating,Ics=75% Icu ,415 volts AC complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with minimum capacity 200 Amp bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification including taking down old complete all as specified and directed.
S&F in renewal MCB SPN 40 Amp C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB 6 Amp to 32 Amp SP capacities 'C' series, 240 V, 10KA rupturing capacaity complete all as specified and directed.
M&L for Sub main wiring with 2 runs of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for iron sheet box for protection of DB not less than 40x40x30mm made of 22 gauge iron sheet with hinged door at one side duly painted by primer and two coats of synthetic enamel paint and fixed to wall with suaitable size of fastners complete all as specified and directed.
S&F in replacement of unserviceable flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium housing in powder coated die-casting power coated in gray finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 KV surge protection of 150 W LED 6000K complete all as specified and directed. Note : Cost of necessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay /low bay luminaires,security light /high mast light fittings etc shall be deemed to be included in the unit rate quoted.
S&F in replacement of unserviceable flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium housing in powder coated die-casting power coated in gray finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 KV surge protection of 60 W LED 6000K complete all as specified and directed. Note : Cost of necessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay /low bay luminaires,security light /high mast light fittings etc shall be deemed to be included in the unit rate quoted.
S&F in replacement of unserviceable flame proof light of 2x16/40 Watt, 4' long with die cast aluminium housing with resistance toughten glass with LED tube light fixture driver, holder, connector etc prewired including connecting up with 3 core copper cable in steel flexible pipe complete all as specified and directed.
M&L for copper plate of size 30x30x3.15mm suitable for discharging of electron charge from human body and fixed to wall with suitable size of fasteners and insulator and duly connected with earthing test point complete all as specified and directed.
M&L for replacement of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled & screwed including 3 Nos 8mm dias , 25mm long hexagonal head screw complete all as specified and directed.
S&F in replacement of copper strip 20x3.15mm with saddels and fixing screws for roof conductors and down conductors above ground , earth continuity conductor or main earthing lead fixed to wwall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or fixed to wall on insulators or any other indicating situation for loop earthing as required 20x3.15mm copper strip complete all as specified and directed.
S&F in replacement of aluminium strip 23x3.15mm with saddels and fixing screws for roof conductors and down conductors above ground complete all as specified and directed.
S&F in replacement of air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S&F in replacement HDPE pit cover of existing size complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 25X4mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion. Note: (i) Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc. complete all as specified and directed. (ii) The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level.
M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 20X3mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion. Note: (i) Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc. complete all as specified and directed. (ii) The unit rate includes for protection pipe and GI strip 20 x 3mm from top of earth plate up to 7.5 meter above ground level.
M/S SOLANKI GENERAL SUPPLIERS
M/s Ramniwas Bishnoi
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .