Tender Value
Refer Docs
EMD Value
₹3,500
Closing Date
13 Jan 2020, 2:00 pmClosed
The Director
ICAR-Sugarcane Breeding Institute, Coimbatore-641007, Tamilnadu
Conversion of existing power control systems into wall mount bus bar units in Physiology Section
2019_DARE_529230_1
SBI/ESTATE/3-4/2019-20
Open Tender
Miscellaneous Services
Works
45 days
ICAR-Sugarcane Breeding Institute
As per tender document
2 documents required · 2 mandatory
₹0
₹3,500
Yes
12 Feb 2020
20 Dec 2019
14 Jan 2020
20 Dec 2019
13 Jan 2020
20 Dec 2019
20 Dec 2019 - 13 Jan 2020
Conversion of existing power control systems into wall mount bus bar units
Supply and clamping of existing 3.5x35/50 Sqmm PVC LTUG armoured cable on wall with MS Clamp. Complete as directed by the department officers. (U.G Cable will be supplied by the Dept).
Supply and Fixing of brass Cable Gland flange type suitable for 3.5x35/50 sqmm PVC LTUG armoured cable with earth connection. Complete as directed by the department officers.(U.G Cable will be supplied by the Dept).
Supply and provided cable end termination of 3.5x35/50sqmm PVC LTUG armoured cable with necessary aluminium cable socket by crimping etc. with electrical connection. Complete as directed by the department officers (U.G Cable will be supplied by the Dept)..
Supply and run of 1 of No 8 SWG Copper Wire for Earth connection. Complete as directed by the department officers.
Supply and run of 4 of 6Sqmm PVC insulated multi copper wire of 1100 Volt grade in suitable Pvc rigid pipe on wall and ceiling with continuous earth wire connection of 1.5 Sqmm Copper wire with painting of suitable colour. Complete as directed by the department officers.
Supply and run of 4 of 4Sqmm PVC insulated multi copper wire of 1100 Volt grade in suitable Pvc rigid pipe on wall and ceiling with continuous earth wire connection of 1.5Sqmm Copper wire with painting of suitable colour. Complete as directed by the department officers.
Supply and run of 2 of 4Sqmm PVC insulated multi copper wire of 1100 Volt grade in suitable Pvc rigid pipe on wall and ceiling with continuous earth wire connection of 1.5 SqmmCopper wire with painting of suitable colour. Complete as directed by the department officers.
Supply and run of 2 of 2.5 Sqmm PVC insulated multi copper wire of 1100 Volt grade in suitable Pvc rigid pipe on wall and ceiling with continuous earth wire connection of 1.5 SqmmCopper wire with painting of suitable colour. Complete as directed by the department officers.
Supply and run of 2 of 1.5 Sqmm PVC insulated multi copper wire of 1100 Volt grade in suitable Pvc rigid pipe on wall and ceiling with continuous earth wire connection of 1.5 SqmmCopper wire with painting of suitable colour. Complete as directed by the department officers.
Supply and erection of 150 Amps 3 Phase 4 wire L.T Bus–bar wall mounting/floor mounting weather proof type made out of heavy gauge sheet steel fabrication on suitable A.I Frame work with cable entry box as per ISI Specification and also accepted by CEIG for accommodating of suitable size UG Cables. The Bus bar should be painted suitable colour paint and inter connection should be made by suitable size flat and capacity of 150 Amps capacity. The bar has been erected proper concrete and inter connected by copper conductor from the panel with earth connection by No 8 SWG copper conductor with lock key arrangements, and accommodate the following switches 1.Incommer-150AMPS TPN Main -1No 2 Three Phase Double Door 8 Way DB-1 Set. 3.100A-4 Pole MCB- 1No 4. 63A 4 Pole MCB -1No 5 20A,16A Single Pole MCB-12+12 =24Nos 6.Three Phase Indicator Lamps-One Set 7..Electronic meters for Voltage, Current, and frequency- One set Complete as directed by the department officers
Supply and erection of 150 Amps 3 Phase 4 wire L.T Bus–bar wall mounting/floor mounting weather proof type made out of heavy gauge sheet steel fabrication on suitable A.I Frame work with cable entry box as per ISI Specification and also accepted by CEIG for accommodating of suitable size UG Cables. The Bus bar should be painted suitable colour paint and inter connection should be made by suitable size flat and capacity of 150 Amps capacity. The bar has been erected proper concrete and inter connected by copper conductor from the panel with earth connection by No 8 SWG copper conductor with lock key arrangements, for accommodate / connect the existing UG Cable and Incoming switches.
Dismantling of existing power DB’S, boxes and connecting cables etc. Complete as directed by the department officers.
Earthing as per standard specification with earth electrode of 50mm 2mtrs hot dip galvanized 45 micron thickness with chemical 25 KG (pentanite 60%, coal30%, graphite 10%) with necessary
S V ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].