Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC L1 STATUS | |
| 2 | L2₹36.4 L+₹2.7 L (8.09%)Rejected-AOC H NO 30 2 83 WARD NO 18 PRASHANTH NAGAR COLONY NEW PALVANCHA BHADRADRI KOTHAGUDEM DISTRICT TELANGANA 507115 | BHADRADRI KOTHAGUDEM | TELANGANA | 507115 | L2 | Rejected-AOC L2 STATUS, HENCE REJECTED. | |
| 3 | L3₹39.0 L+₹5.4 L (16.0%)Rejected-AOC H NO 1 77 1 VIJAYANAGARAM COLONY KONDAIEGUDEM POST MANUGURU 507117 BHADRADRI KOTTAGUDEM DIST TELANGANA STATE | BHADRADRI KOTHAGUDEM | TELANGANA | 507117 | L3 | Rejected-AOC L3 STATUS, HENCE REJECTED. | |
| 4 | L4₹39.3 L+₹5.6 L (16.7%)Rejected-AOC 12 HARMONY RESIDENCY NEAR PANCHMUKHI HANUMAN MANDIR VASNA BHAYLI ROAD VADODARA VADODARA GUJARAT 391410 | VADODARA | GUJARAT | 391410 | L4 | Rejected-AOC L4 STATUS, HENCE REJECTED. | |
| 5 | Rejected-Technical H NO 3 79 ASWAPURAM ASWAPURAM M BHADRADRI KOTHAGUDEM DIST TELANGANA STATE 507116 | BHADRADRI KOTHAGUDEM | TELANGANA | 507116 | - | Rejected-Technical Not Meeting ENIT conditions |
| Sl No | Description | Qty | Unit | POWER TECH SERVICES L4 | M/s P N R ENGINEERING WORKS L3 | M/s K S EVEREST ENGINEERING WORKS L2 | SRI VENKATA DURGA CONSTRUCTIONS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Preventive Maintenance of circuit breakers of following voltage level and type: | |||||||
| 1.01 | 220kV SF6 | 8 | No. | 1,000 ₹8,000 | 980 ₹7,840 | 700 ₹5,600 | 500 ₹4,000 Lowest |
| 1.02 | 33 kV VCB | 32 | No. | 700 ₹22,400 | 675 ₹21,600 | 550 ₹17,600 | 400 ₹12,800 Lowest |
| 1.03 | 11 kV VCB | 8 | No. | 725 ₹5,800 | 700 ₹5,600 | 500 ₹4,000 | 400 ₹3,200 Lowest |
| 1.04 | 415V ACB | 12 | No. | 500 ₹6,000 | 475 ₹5,700 | 350 ₹4,200 | 250 ₹3,000 Lowest |
| 2.00 | Preventive maintenance of 220kV Isolators | 16 | No. | 700 ₹11,200 | 675 ₹10,800 | 450 ₹7,200 | 350 ₹5,600 Lowest |
| 3.00 | Preventive maintenance of 220kV switchyard bay marshalling box | 20 | No. | 985 ₹19,700 | 900 ₹18,000 | 700 ₹14,000 | 500 ₹10,000 Lowest |
| 4.00Preventive maintenance of switchgear panel of following voltage level: | |||||||
| 4.01 | 33kV | 30 | No. | 1,400 ₹42,000 | 1,375 ₹41,250 | 1,000 ₹30,000 | 550 ₹16,500 Lowest |
| 4.02 | 11kV | 8 | No. | 925 ₹7,400 | 900 ₹7,200 | 750 ₹6,000 | 500 ₹4,000 Lowest |
Tender Value
₹37.6 L
EMD Value
₹75,300
Closing Date
31 May 2025, 6:45 pmClosed
General Manager
General Manager , HWP(M).
Biennial Electrical Maintenance Works at Captive Power Plant, HWP, Manuguru during the period 2025-27.
2025_HWB_860991_1
HWPM/EU/AMC/2025/01/NIT , Dt.15.05.2025
Open Tender
Electrical Works
Item Rate
730 days
EU, CPP - HWPM, Aswapuram
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹75,300
26 Sept 2025
23 May 2025
6 Jun 2025
23 May 2025
31 May 2025
23 May 2025
23 May 2025 - 27 May 2025
Amount
Preventive Maintenance of circuit breakers of following voltage level and type:
33 kV VCB
11 kV VCB
Preventive maintenance of 220kV Isolators
Preventive maintenance of 220kV switchyard bay marshalling box
Preventive maintenance of switchgear panel of following voltage level:
Preventive Maintenance of transformers of following rating:
220/33kV, 40MVA
33/11kV, 40MVA
33/6.6kV, 16MVA
11/6.6kV, 8MVA
Below 8MVA
Oil topup in transformers of following rating:
Above 8MVA
8MVA and below
Replacement/Drying of Silica Gel of transformer
Arresting of oil leak from transformer of following rating:
220/33kV, 40MVA
33/11kV, 40MVA
33/6.6kV, 16MVA
11/6.6kV, 8MVA
Below 8MVA
Transformer oil sample collection and testing(for BDV) as per relevant Indian standard. BDV kit will be provided by department
Disconnection of power cables from transformer(rated 40 MVA) terminals(after opening terminal box cover) for the purpose of measuring of IR value and subsequent connection and closing of terminal boxes. Measurement of IR value covered in other item.
Disconnection of ground connection from transformer(rated 40 MVA) neutral terminals for the purpose of measuring of IR value and subsequent connection. Removal and reconnection of any other ground connections in the circuit are also covered in this item. Measurement of IR value covered in other item.
Disconnection of power cables from transformer(rated between 8MVA and 40MVA) terminals(after opening terminal box cover)/bus bar terminals for the purpose of measuring of IR value and subsequent connection and closing of terminal boxes. Measurement of IR value covered in other item
Disconnection of ground connections from transformer(rated between 8MVA and 40 MVA) neutral terminals for the purpose of measuring of IR value and subsequent connection. Removal and reconnection of any other ground connections in the circuit are also covered in this item. Measurement of IR value covered in other item.
Disconnection of power cables from transformer(rated 8 MVA and less) terminals(after opening terminal box cover) for the purpose of measuring of IR value and subsequent connection and closing of terminal boxes. Measurement of IR value covered in other item.
Disconnection of ground connections from transformer(rated 8MVA and less) neutral terminals for the purpose of measuring of IR value and subsequent connection. Removal and reconnection of any other ground connections in the circuit are also covered in this item. Measurement of IR value covered in other item.
Removal of existing Oil Temperature indicator/Winding temperature indicator of transformer and replacing it with spare by proper mounting. Connection and disconnection of indicator terminals from marshalling box is in the scope of contractor
Measurement of Insulation resistance value/ Polarisation index value of transformer winding/power cable/circuit breaker/bus bar/motor etc.
Measurement of dielectric disspitation factor/Capacitance value of insulations of 220kV CT/PT/transformer/OIP bushing
Troubleshooting of control/protective/power circuits of 220kV circuit breaker/ 220kV isolator/ 220/33kV 40MVA transformer/220kV CT/220kV PT etc.
Troubleshooting of control/protective/power circuits of 33kV switchgear/33kV breakers/33kV-11kV-6.6kV voltage level transformers etc.
Troubleshooting of control/protective/power circuits of 6.6kV-415V voltage level transformer/6.6kV motor etc.
Troubleshooting of control/protective/power circuits of 415V circuit breaker/ 415V transformer/ 415V switchgear/ 415V motor etc.
Troubleshooting of control/protective circuits of 220V DC/48V/24V DC system
Improvement of IR value to satisfactory value(as directed by EIC) of 33kV outgoing cubicle by hot air blowing/ heating with luminaires etc.
Improvement of IR value of 415V motor to satisfactory value(as directed by EIC) by hot air blowing in terminal box/ heating with luminaires etc.
Preventive Maintenance of HT motor
Condition monitoring of HT motor
Improvement of IR value of 6.6kV motor to satisfactory value(as directed by EIC) by hot air blowing in terminal box/ heating with lumiaires etc.
Preventive Maintenance of LT motor and its module
Condition monitoring of LT motor
Temporary power supply connection / disconnection at different location (material collection from plant store and safe return to plant in contractor scope)
Condition monitoring of LT module
Shifting of CTs/PTs/LT motors/Control transformers/testing kits etc. from DPS store/E-U store to site/site to store when required
Removal of connection of 220KV overhead conductors from OIP bushings for testing of bushings and re-termination after completion of testing
Pre-monsoon checks of transformers as per checklist
Disconnection of cables from motors/overhead lines/TBs etc. for troubleshooting etc. and reconnecting after completion of troubleshooting
Supply of paint and painting of the surface of cable tray/panel/motor/exhaust fan etc. Minimum quantity of synthetic enamel smoke grey paint to be supplied: 60 litres
Preparation of various documents in system as per technical specifications
Supply of 1.5V AA cells as and when required, Make: Duracell
Supply of 9V cells as and when required, Make: Duracell
Puncture Repair of cargo loader tyre as and when required as per technical specifications
Installation of quarter turn locks(Zinc die casting body, steel cam, chrome plating) including supply of lock with key for electrical panel of following dimensions:Panel cut-out:22mm dia.(approx.) as per sample. Grip length upto 100mm as per sample.
De-dusting of modules/panels, Segregation of spares/scrap in section stores etc.
Fabrication, painting(one coat each of red oxide and synthetic enamel grey) of support angles/transformer control cabinet canopy/cable tray canopy/neutral grounding resistor enclosure etc. including supply, cutting, welding of MS sheet/plate/angle of required thickness, required GI nuts, bolts, plain and spring washers and fixing at site as per technical specifications. Supply of red oxide and synthetic enamel grey paint is also in the scope of contractor
Supply of magnetic oil gauge suitable for 33kV/6.6kV 10/16 MVA transformer as per technical specifications. Make: Sukrut/Yogya/Atvus/Viat
Replacement of supplied magnetic oil gauge as per item Sl.No.47 as per technical specifications
Supply and replacement of control transformer in HV testing kit. Specification of transformer: 230V/115V,50Hz, 300VA. Double winding type, Chassis mount
M/s K S EVEREST ENGINEERING WORKS (BID ID -3223961)
M/s P N R ENGINEERING WORKS (BID ID -3222960)
POWER TECH SERVICES (BID ID -3222048)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .