Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | ₹9.0 L Quoted ₹9.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹10.3 L+₹38,965 (3.94%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹10.3 L+₹38,965 (3.94%) | L2 | Rejected-Finance NOT L1 |
| 3 | L3₹10.6 L+₹69,852 (7.06%)Rejected-Finance | ₹10.6 L+₹69,852 (7.06%) | L3 | Rejected-Finance NOT L1 |
| 4 | L4₹10.6 L+₹73,359 (7.41%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | ₹10.6 L+₹73,359 (7.41%) | L4 | Rejected-Finance NOT L1 |
| 5 | L5₹10.7 L+₹79,094 (7.99%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹10.7 L+₹79,094 (7.99%) | L5 | Rejected-Finance NOT L1 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
12 Aug 2021, 6:00 pmClosed
AGE I A Jamnagar
INFANTRY LINES JAMNAGAR
REPAIRS TO SUMMER APPLIANCES SUCH AS CEILING FANS, EXHAUST FANS, GEYSERS AND CONNECTED ITEMS AT OTM ACCN AT MIL STN JAMNAGAR.
2021_MES_462068_1
8826
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Jamnagar
AS TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
AGE I ARMY JAMNAGAR
₹18,000
Yes
15 Sept 2021
23 Jul 2021
13 Aug 2021
24 Jul 2021
12 Aug 2021
29 Jul 2021
Amount
Taking down ceiling fan any type from hook and sealing cable and dismantling blades and removing to store for repair any make and sweep all as directed by Engr in charge and hanging ceiling fan in position after repair greasing etc. and painting and connecting up including provision of cable from ceiling rose of connecter to fan flexible copper cable of size 23/00076 complete directed at site (Note: re-winding of fan and parts required shall be measured and paid separately under relevant item of sch 'A')
M & L for re-winding of ceiling fan 1200 mm sweep with super enamelled copper wire as per existing size/gauge
M & L for re-winding of ceiling fan 1400 mm sweep with super enamelled copper wire as per existing size/gauge
Taking down Exhaust/pedestal/wall mounted fan any type sealing cable and dismantling blades and removing to store for repair any make and sweep all as directed by Engr in charge and hanging exhaust fan in position after repair greasing etc. and painting and connecting up including provision of cable from ceiling rose of connecter to fan flexible copper cable of size23/00076 canopy complete directed at site (rewinding of fan painting and parts required shall be measured and paid separately)
M & L for re-winding of Exhaust fan of 230/300/325mm sweep complete all as specified and directed by Engineer-in-Charge.
M & L for re-winding of exhaust fan 300mm to 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix condenser 2.5 Mfd including dismantling of unserviceable condenser, reconnection and testing complete all as specified and directed by Engineer-in-Charge. Make: Havells / Tibcon / Seimens
Supply and fix including removing of unserviceable condenser and replacement with new condenser 4 Mfd (+) or (-) 10% of approved make including connecting soldering complete all as specified and directed by Engineer-in-Charge. Make: Havells/ Seimens/TIBCON
Supply and fix including dismantling, removing of unserviceable ball bearing (in ceiling fan) and replacement with original size ball bearing of following sizes and approved make to suit the respective make including testing and commissioning complete all as specified and directed by Engineer-in-Charge. : Make: Tata / NBC / SICF
(a) Ball bearing No 6201
(b) Ball bearing No 6202
(c) Ball bearing No 6203
Supply and fix in replacement of old unserviceable gun metal bushes for ceiling fans of same type, size and shape as per existing bushes of approved make complete all as specified and directed by Engineer-in-Charge.
M&L for painting of complete ceiling fans, exhaust fans at site, with one coat of synthetic enamel paint (white/smoke grey) including writing of MES No. with black paint complete all as specified and directed by Engineer-in-Charge.
(a) Ceiling fan of 1200mm sweep.
(b) Ceiling fan of 1400mm sweep.
(c) Exhaust fan of 230/300/325mm sweep.
(d) Exhaust fan of 380/400/450mm sweep.
Supply & fix in replacement of ceiling fan blades (set of three) suitable for any make and size as approved and complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of canopy suitable for ceiling fan of any make and size as approved and complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Ceiling fan Down rods 30/45cm long complete as per existing size complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of copper Flexible cable twisted 3core 1.00 Sqmm for fan connection complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of clamp Heavy duty for hanging celing fan as per existing size including 2 No of Nuts bolts with lock pin rubber seal complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Electronic fan regulator step type (5 Steps) 2module 100/120w ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc, complete all as specified and directed by Engineer-in-Charge.
WINDOW/ SPLIT TYPE AC
M & L for tracing out the leakage from suction line, discharge line, evaporation condenser, filter, capilary tube by suitable method including brazing, welding, replacement of filter Strainer charging line and filling of gas R-22 in window type AC capacity 1.5/2 TR complete all as specified and directed by Engineer-in-Charge.
M & L for tracing out the leakage from suction line, discharge line, evaporation condenser, filter, capilary tube by suitable method including brazing, welding, replacement of filter Strainer charging line and filling of gas R-22 in split type A/C 1.5 /2.0 Ton capcity complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of starting capacitor of 100/120 MFD, 230 Volt AC suitable for 1.5 TR/2.0TR capacity AC complete all as specified and directed by Engineer-in-Charge. Make : Usha/Keltron/ BHEL /KEL/Texla
M & L for removing existing unserviceable compressor cut/uncut from window type/split A/C and replacement of factory reconditioned clean compressor ( with 1 year replacement warranty), in exchange suitable for 1.5/2 ton capacity A/C including fixing in original position, with filling of gas R-22 and pressure testing including welding, brazing replacement of filter/Strainer made of copper capilary tube, complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of running capacitor 50/40 mfd 230 Volt AC suitable for 1.5 Ton capacity AC complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of capacitor, 6 MFD, 240 Volt AC suitable for condenser motor 1/6 HP 1350 RPM complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of overload protector AC suitable for 1.5 TR/2.0 TR capacity complete all as specified and directed by Engineer-in-Charge. Make : Usha /Shriram/ISI marked.
Supply & fix in replacement of starting relay box type R-22 suitable for 1.5TR/2.0TR capacity A/C complete all as specified and directed by Engineer-in-Charge.
M & L for removing of existing unserviceable burnt condenser motor from window/split type AC 1.5/2.0 ton capacity and replacement of condenser motor of capacity 1/6 HP 1350 RPM as per existing single phase 230 V including fixing in original position with replacement rubber bush of motor mounting, testing complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of copper condenser in split type air conditioner outdoor unit complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of electronic circuit complete including controling unit ie (Remote) all as per existing sample and suitable for 1.5 / 2.0 Ton capacity split type AC complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Copper pipe 1/4 with u Foam for 1.5/2 ton capacity split AC complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Copper pipe 5/8 with u Foam for 1/5/2 ton capacity split AC complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of copper AC suction valve of size 5/16 complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of copper AC suction valve of size 5/8 complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of rubber pipe for waste water of 15mm complete all as specified and directed by Engineer-in-Charge.
M & L for servicing of window/Split type A/C unit 1.5/2.0 ton capacity removing from existing position (Indoor & Outdoor unit both in case of split AC) and washable servicing the same by complete cleaning & washing the dust by suitable blower machine method including supply and replacement of air filter, damaged wires with copper wire PVC insulated of same size, tightening of loose wire, nuts, bolts, servicing of condenser motor, by oiling, greasing, supply and replacement of bushes of condenser motor, damaged knobs, setting of grills alignment complete including refixing in original position including provision of thermocoal for air thightness, testing and commissioning to the entire satisfaction of Engineer-in-Charge.
REFRIGERATORS
M & L for tracing out the leakage from suction/ discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-134a, replacement of strainer, capilary tube, nut bolts of compressor of refrigerators of different capacities etc, complete all as specified and directed by Engineer-in-Charge.
M & L for removing existing unserviceable compressor cut/uncut from Refrigerator capacity 286/310 ltrs and replacement of factory reconditioned compressor ( with 1 year replacement warranty) clean exchange including fixing in original position charging of gas R-134a, replacement of strainer, capillary tube complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of thermostat defrost type for refrigerator.
S&F in replacement condenser in outer side of refregerator
S&F in replacement of 15 Watt lamp screw/Pin type for refrigerator complete all as specified and directed by Engineer-in-Charge. Make : Phillips/Bajaj
S&F in replacement of cooling coil with PVC freezer door complete with screw/nut bolt suitable for 286/310 ltrs capacity refrigerator complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of over load relay suitable for 280/310 Ltrs capacity refrigirator as per existing complete all as specified and directed by Engineer-in-Charge.
WATER COOLER
M & L for tracing out the leakage from suction/discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-22, replacement of strainer, capilary tube, nut bolts of compressor of water cooler 40/80 ltrs capacity complete all as specified and directed by Engineer-in-Charge.
M&L for removing of existing unserviceable compressor cut/uncut from water cooler 120/150 ltrs capacity and replacement of factory reconditioned clean compressor ( with 1 year replacement warranty) suitable for existing water cooler 120/150 ltrs capacity including fixing in original position with filling R-22 gas charging and pressure testing ,brazing replacement of stainer, capilary tube cleaning of condenser coil etc complete all as specified and directed by Engineer-in-Charge.
M & L for removing of existing unserviceable burnt condenser motor from water cooler 120 to 320 ltr capacity and replacement of condenser motor of capacity 1/30 HP 1350 RPM as per existing single phase 230 V including fixing in original position with replacement rubber bush of motor mounting, testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of starting relay box type for 120/150 ltrs capacity Water Cooler including overload protector complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of thermostat including knob, plate and screw suitable for 120/150 ltrs capacity storage type water coolercomplete all as specified and directed by Engineer-in-Charge.
S&F in replacement of push cock, lifting cock 15mm size as per existing pattern for water cooler complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC drain pipe approx 1.5 mtr long of 25mm dia for water cooler complete with clamp screws etc complete for drainout water from water cooler complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Float valve, chromium plated with polythene PVC ball for 15mm (1/2") bore size suitable for 40/80 ltrs capacity water cooler complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of chromium plated drain pot suitable for collecting drain water from 120/150 ltrs water cooler, as per existing pattern complete all as specified and directed by Engineer-in-Charge.
S&F in replacement condenser suitable for 120/150 Ltrs capacity water cooler as per existing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of capacitor 10 MFD, 440 Volt AC. complete all as specified and directed by Engineer-in-Charge.
DEEP FREEZER
M & L for tracing out the leakage from suction/ discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-134a, replacement of strainer, capilary tube, nut bolts of compressor of deepfreezer of different capacities etc, complete all as specified and directed by Engr-in-Charge.
M & L for removing existing unserviceable compressor cut/uncut from Deep freezer of capacity 320 ltrs and replacement of factory reconditioned compressor (with 1 year replacement warranty) clean exchange including fixing in original position charging of gas R-134a, replacement of strainer, capillary tube complete all as specified and directed by Engr-in-Charge.
M & L for removing of existing unserviceable burnt condenser motor from deep freezer of 320 ltr capacity and replacement of condenser motor of capacity 1/30 HP 1350 RPM as per existing single phase 230 V including fixing in original position with replacement rubber bush of motor mounting, testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement thermostat suitable for 320 Ltrs capacity deep freezer as per existing complete all as specified and directed by Engr-in-Charge.
S&F in replacement condenser suitable for 320 Ltrs capacity deep freezer as per existing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of over load relay suitable for 320 Ltrs capacity deep freezer as per existing complete all as specified and directed by Engr-in-Charge.
M/s Jagdish Machinery Stores
Dara Paras.D
fakhrie apostrical
SURESH ELECTRICALS
Ravi enterprise
Hirachand Sunderji and co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .