Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L1 | Accepted-AOC L-1 Bidder | |
| 2 | L2₹18.0 L+₹2.8 L (18.6%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹20.7 L+₹5.6 L (36.7%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹21.4 L+₹6.3 L (41.2%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | Rajesh Enterprises L3 | M/s Shiv Builder and Suppliers L1 | Nikhat nirman L4 | M/S KAUTILYA GARG L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium Each Point wiring for light, fan, bell socket power slocket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose etc complete | 876 | Each Point | 10 ₹8,760 Lowest | 25 ₹21,900 | 20 ₹17,520 | 10 ₹8,760 Lowest |
| 2.00 | M & L for Surface Conduit Point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLS cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC concealed conduit of size 20 mm or med grade as required as site, fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc/Surface PVC Box (as per site requirement/directed at site) incl 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly, suitable for One light/ fan/ bell Point controlled by one, one way switch, complete all as specified and directed. | 152 | Each Point | 500 ₹76,000 | 335 ₹50,920 Lowest | 600 ₹91,200 | 500 ₹76,000 |
| 3.00 | All as per item No. 2.00 here-in-above, but one socket outlet 3 pin 5/6 Amps on same board | 20 | Each Point | 100 ₹2,000 | 45 ₹900 Lowest | 400 ₹8,000 | 100 ₹2,000 |
| 4.00 | All as per item No. 2.00 here-in-above, but one socket outlet 3 pin 5/6 Amp on independent board | 30 | Each Point | 500 ₹15,000 | 375 ₹11,250 Lowest | 600 ₹18,000 | 500 ₹15,000 |
| 5.00 | All as per item No. 2.00 here-in-above, but one light Each Point controlled by two, two-way switches | 1 | Each Point | 500 ₹500 | 385 ₹385 Lowest | 700 ₹700 | 500 ₹500 |
| 6.00 | All as per item No. 2.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable(FRLS) including 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 6 pin 16 Amp socket outlet on independent board . | 20 | Each Point | 650 ₹13,000 | 400 ₹8,000 Lowest | 800 ₹16,000 | 700 ₹14,000 |
| 7.00 | M & L for (concealed) Point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLS cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC concealed (including Cutting Chases and make good the distrubed surfaces ) conduit of size 20 mm or med grade as required as site, totally concealed in walls / and surface on floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, suitable for One light/ fan/ bell Point controlled by one, one way switch, complete all as specified and directed.
Note:- The quoted rate is deemed cost of chase cutting on wall for concealed conduit and steel terminal boxes. | 152 | Each Point | 500 ₹76,000 | 390 ₹59,280 Lowest | 600 ₹91,200 | 500 ₹76,000 |
| 8.00 | All as per item No. 7.00 here-in-above, but one socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch. | 20 | Each Point | 500 ₹10,000 | 45 ₹900 Lowest | 400 ₹8,000 | 500 ₹10,000 |
| 9.00 | All as per item No. 7.00 here-in-above, but one socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch. | 20 | Each Point | 110 ₹2,200 | 395 ₹7,900 | 600 ₹12,000 | 100 ₹2,000 Lowest |
| 10.00 | All as per item No. 7.00 here-in-above, but one light Point controlled by two, two-way switches | 1 | Each Point | 500 ₹500 | 410 ₹410 Lowest | 700 ₹700 | 500 ₹500 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
29 Aug 2025, 6:00 pmClosed
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
REPAIR REPLACEMENT OF SUB MAIN WIRING, FIRE FIGHTING, LIGHTING ALISTER, EARTIHING INCLUDING DBs AND MISC WORK UNDER GE (ARMY) No 1 JODHPUR.
2025_MES_723523_1
GE/JODH (A) No 1 OF 2025-26 (9352/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jodhpur
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (A) No 1
₹60,000
Yes
11 Oct 2025
30 Jul 2025
5 Sept 2025
30 Jul 2025
29 Aug 2025
15 Aug 2025
Amount
Taking down carefully copper/aluminium Each Point wiring for light, fan, bell socket power slocket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose etc complete
M & L for Surface Conduit Point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLS cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC concealed conduit of size 20 mm or med grade as required as site, fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc/Surface PVC Box (as per site requirement/directed at site) incl 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly, suitable for One light/ fan/ bell Point controlled by one, one way switch, complete all as specified and directed.
All as per item No. 2.00 here-in-above, but one socket outlet 3 pin 5/6 Amps on same board
All as per item No. 2.00 here-in-above, but one socket outlet 3 pin 5/6 Amp on independent board
All as per item No. 2.00 here-in-above, but one light Each Point controlled by two, two-way switches
All as per item No. 2.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable(FRLS) including 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 6 pin 16 Amp socket outlet on independent board .
M & L for (concealed) Point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLS cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC concealed (including Cutting Chases and make good the distrubed surfaces ) conduit of size 20 mm or med grade as required as site, totally concealed in walls / and surface on floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, suitable for One light/ fan/ bell Point controlled by one, one way switch, complete all as specified and directed. Note:- The quoted rate is deemed cost of chase cutting on wall for concealed conduit and steel terminal boxes.
All as per item No. 7.00 here-in-above, but one socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
All as per item No. 7.00 here-in-above, but one socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
All as per item No. 7.00 here-in-above, but one light Point controlled by two, two-way switches
All as per item No. 7.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable (FRLS)including 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 6 pin 16 Amp socket outlet on independent board .
M&L for Point wiring complete with using 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade, ISI Marked, passing in existing PVC/ steel conduit fixed on on surface of wall / roof / ceiling or concealed etc in sunken pressed steel terminal boxes in wall or with pressed flush metal boxes covered with inner plates & outer plates etc,/including 3.00 mm thick plastic laminated hylem sheet and 1.50 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) cable for common earth and connecting to earth dolly, suitable for One light/ fan/ bell Point controlled by one, one way switch, complete all as specified and directed.
All as per item No. 12.00 here-in-above, but one socket outlet 3 pin 5/6 Amps on same board
All as per item No. 12.00 here-in-above, but one socket outlet 3 pin 5/6 Amp on independent board
All as per item No. 12.00 here-in-above, but one light Point controlled by two, two-way switches
All as per item No. 12.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable (FRLS)and 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 6 pin 16 Amp socket outlet on independent board .
M&L for modular Point wiring (Concealed) using approved colour coding as per IS Red/Yellow/Blue, Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FR LS cable 1100 Volts grade ISI 694 marked with valid CML No. in and including medium grade PVC concealed conduit of dia not less than 20mm and conduit accessories ISI marked with valid CML No. ( IS 9537 -1983 for wall/roof /floor etc with pressed flush metal boxes covered with inner plates & outer plates etc suitable for mounting of modular switches & sockets including PVC insulated multi stranded copper conductor FRLS 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continully conductor to common earth and connecting to earrth dolly, suitable for One light/ fan/ bell Point controlled by one, one way switch, complete all as specified and directed. Note:- The quoted rate is deemed cost of chase cutting on wall for concealed conduit and steel terminal boxes.
All as per item No. 17.00 here-in-above, but one socket outlet 3 pin 6 Amps on same board
All as per item No. 17.00 here-in-above, but one socket outlet 3 pin 6 Amp on independent board
All as per item No. 17.00 here-in-above, but one light Point controlled by two, two-way switches
All as per item No. 17.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable (FRLS)and 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 6 pin 16 Amp socket outlet on independent board .
S&F switch piano flush type 6 amp single pole one way 230 Volts complete all as specified & directed .
S&F switch piano flush type 6 amp single pole two way 230 V complete all as specified & directed .
S&F switch piano flush type 16 amp single pole one way 230 V Complee all as specified & directed .
S&F bell push AC, 230 Volts, 5 Amps complete all as directed.
S&F socket out let flush type 6 amp 3/5 pin suitable for 6 Amp plug top 230 V complete all as specified & directed.
S&F in replacement socket out let flush type 6 amp 3/5 pin suitable for 6 Amp plug top 230 V including taking down of old unserviceable socket, complete all as specified & directed.
S&F socket out let flush type 3/6 pin suitable for 16 Amp plug top multipurpose 230 V complete all as specified & directed.
S&F bell AC ding dong type 230 volts, complete all as specified & directed.
S&F in replacement bell AC ding dong type 230 volts, including taking down of old unserviceable bell, complete all as specified & directed.
S&F fan regulator electronic Switch/socket type, complete all as specified and directed.
S&F in replacement fan regulator electronic switch/ socket type, including taking down of old unserviceable fan regulator, complete all as specified & directed.
S&F lamp holder insulated body with back plate batten/angle type for batten fittings, complete all as specified and directed.
S&F in replacement lamp holder insulated body with back plate batten/angle type for batten fittings, including taking down of old unserviceable lamp holder complete all as specified and directed.
S&F in replacement fan capacitor 2.5 m.f.d for ceiling Fan, including taking down of old unserviceable capacitor, complete all as specified and directed.
S&F in replacement ceiling rose 3 terminals, including taking down of old unserviceable ceiling rose, complete all as specified and directed.
S&F modular switch, 6 amp, one way, 230 V, complete all as specified and directed.
S&F in replacement modular switch, 6 amp, one way, 230 V, including taking down of old unserviceable ceiling rose, complete all as specified and directed.
S&F modular switch, 16 amp, one way, 230 V, complete all as specified and directed.
S&F in replacement modular switch, 16 amp, one way, 230 V, including taking down of old unserviceable ceiling rose, complete all as specified and directed.
S&F modular socket, 6 amp 5 Pin one way 230 V, complete all as specified and directed.
S&F in replacement modular socket, 6 amp 5 Pin one way 230 V, including taking down of old unserviceable socket, complete all as specified and directed.
S&F modular socket 16 amp 5 Pin one way 230 V, complete all as specified and directed.
S&F in replacement modular socket 16 amp 5 Pin one way 230 V, including taking down of old unserviceable socket, complete all as specified and directed.
S&F in replacement modular switch, 6 amp, two way, 230 V, including taking down of old unserviceable switch, complete all as specified and directed.
S&F modular fan Regulator step type, 100 watt , 230 Volts, complete all as specified and directed.
S&F in replacement modular fan Regulator step type, 100 watt , 230 Volts, including taking down of old unserviceable fan regulator, complete all as specified and directed.
S&F modular Bell push any type and make 6 amp one way 230 V, complete all as specified and directed.
S&F in replacement modular Bell push any type and make 6 amp one way 230 V, including taking down of old unserviceable bell push, complete all as specified and directed.
S&F in replacement modular cover plate with frame 3 module type for fixing of modular switch socket, regulators, blank plates etc., including taking down of old unserviceable cover plate, complete all as specified and directed.
S&F in replacement modular cover plate with frame 8 module type for fixing of modular switch socket, regulators, blank plates etc, including taking down of old unserviceable cover plate, complete all as specified and directed.
S&F in replacement modular cover plate with frame 12 module type for fixing of modular switch socket, regulators, blank plates etc, including taking down of old unserviceable cover plate, complete all as specified and directed.
S&F in replacement PVC conduit including fitting such as tee,elbow,bend etc 20mm dia ISI (MMS) grade, including taking down of old unserviceable pvc conduit, complete all as specified and directed.
S&F in replacement PVC cassing Capping tee,elbow,bend etc 20/25 mm dia ISI (MMS), including taking down of old unserviceable pvc casing-N-capping, complete all as specified and directed.
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-42 DB's suitable for one MCB SPN as incoming and 2 MCB SP as out going,SPN 4Way, including taking down of old unserviceable DB, complete all as specified and directed.
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 6 MCB SP as out going SPN 8 way, including taking down of old unserviceable DB, complete all as specified and directed.
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 10 MCB SP as out going SPN 12 way, including taking down of old unserviceable DB, complete all as specified and directed.
S&F replacement sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for one No 63 to 100 Amp 10 KA TPN MCCB as incoming, including taking down of old unserviceable DB, complete all as specified and directed.
S&F in replacement MCB Single pole"B" series 5-32 Amps ISI marked, including taking down of old unserviceable MCB, complete all as specified and directed.
S&F in replacement MCB Single pole & neutral "B" series upto 63. Amps ISI marked, including taking down of old unserviceable MCB, complete all as specified and directed.
S&Fin replacement MCB TPN B Curve 63 to 100 Amps, including taking down of old unserviceable MCB, complete all as specified and directed.
S&F in replacement electronic driver as per sample for LED fitting up to 45 watt, including taking down of old unserviceable driver, complete all as specified and directed.
Taking down bldg security light upto 45 watt and repairing, servicing & refixing the same after repair all as specified and directed. Note:- Electronic driver shall be measured & paid sepearately under sch A.
M & L in replacement remote bell ding dong type, including taking down of old unserviceable bell, complete all as specified and directed.
S&F in replacement 2-Watt LED decorative Wall Light (bed light) for reading, including taking down of old unserviceable light, complete all as specified and directed.
S&F in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffusersoft glare free light complete with drivers, holders LED lamp suitable for roof ceiling includin gconnecting up with three core flexible copper conductor cable of suitable size, including taking down of old unserviceable light, complete all as specified and directed.
S&F in replacement Spot light 6 Watts Black/ white Body LED Spot Light, Focus Light (Warm White), including taking down of old unserviceable light, complete all as specified and directed.
S&F in replacement 1.5 sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor, as in existing conduit , including taking down of old unserviceable cable, complete all as specified and directed.
All as per item No. 68.00 here-in-above but cable size 2.5 sqmm
S&F in replacement Street light bracket made out of medium grade GI Pipe, bent to shape including GI Clamps nut,bolts washers,reducer of required size for suitable any type fittings etc complete including necessary painting, including taking down of old unserviceable bracket, complete all as specified and directed.
S&F in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.60 mtr long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm pvc insulated cable, including taking down of old unserviceable light, complete all as specified and directed.
S&F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, including taking down of old unserviceable light, complete all as specified and directed.
S&F in replacement LED lights fitting 1x 20W, 220V, Cool White, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including taking down of old unserviceable light, complete all as specified and directed.
S&F in replcement LED lights fitting 1x 20W, 220V, Warm White, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including taking down of old unserviceable light, complete all as specified and directed.
S&F in replacement Decorative wall light fixture made up of Polycarbonate, suitable for & including 9 W LED lamp B22 base, including taking down of old unserviceable light, complete all as specified and directed.
S&F in replacement Decorative wall light fixture made up of Acrylic, Iron,Warm White, suitable for & including 9 W LED Bulb, including taking down of old unserviceable bulb, complete all as specified and directed.
S & F in replacement LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, including taking down of old unserviceable light, complete all as specified and directed.
M & L in replacement GLS Coloured Lamp Red,Green,Milky,0-60 Watt
S & F in replacement LED Bulb threaded types in holders 0 to 15 Watts as per existing sample given by department
S & F in replacement LED Bulb brown in brightness(Warm tpye) 0 to 15 Watts as per existing sample given by department.
S&F in replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed.
S&F in replacement post top lantern LED type 20 to 40 watt (as per Site requirement) 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, including taking down of old unserviceable light, complete all as specified and directed.
M&L in replacement sub main wiring with PVC insulated and unsheathed 2x 1.5 Sq mm single core multistrandred copper conductor cable(FRLS) passing through in and including PVC conduit surface/Concealed walls with all required with matching good distributed surface accesries of 25 mm dia heavy duty PVC conduit ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 1.5 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire, including taking down old UNSV submain wiring complete all as specified and directed Note :- Two runs of cable 1.5 Sqmm (FRLS) and One run of 1.5 Sqmm copper conductor(FRLS) along with 25 mm dia heavy duty PVC conduit shall be measured as one unit length
All as per item No. 83.00 here-in-above but cable size is 6 sqmm with concealing in wall
All as per item No. 83.00 here-in-above but cable size is 6 sqmm with surface mounted
M & L in replacement Earthing complete with galvanised steel earth plate electrode 60 x x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal/hard/dense ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate No. 3 connected to earthing test Each Point all as specified or indicated including testing on completion . Note : Rates are deemed to be included for necessary earth work , earth pit with RCC cover of size 300X300 x25 mm etc complete all as specified and as directed.
Supply and laying or fixing or passing through pipe in replacement, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections complete all as specified and as directed.
Supply and laying or fixing or passing through pipe in replacement, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 4 core nominal cross section in service connections complete all as specified and as directed.
M & L for road cutting(not more than 3.5 mtr in width of road) and excavation upto 60 cm below ground level and laying of 5 running mtr protection 40 mm dia GI pipe of medium grade and make good distrubuted suface by premix buitman sealed bag/salipach complete all as specified and as directed.
S & F in replacement PVC Surface Box including and with one 6 Amps switch and one 6 Amps sockets complete all as specified and as directed.
S & F in replacement Extension PVC Surface Box including and with two 06 Amps switch and two 06 Amps sockets , 4 meter suitable cable complete all as specified and as directed.
S & F in replacement PVC Surface Box including and suitable for one 16 Amps switch and one 16 Amps sockets complete all as specified and as directed.
S&F in repair 2'x2' energy efficient recess mounting 36 watt LED lumanaries fixing for POP/snapgrid ceiling housing including LED lamps other accessories and necessary electric connection complete all as specified and as directed.
M&L in repairs sub main wiring with PVC insulated and unsheathed 2 x 4 Sqmm signle core multistandered copper conductor cable (FRLS) passing through in and including PVC conduit concealing in walls (by means of chasing including making good existing surface and matching existing surface) ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrubed surface, incl 4 sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note. Two runs of cable 4 Sqmm (FRLS) and One run of 4 Sqmm copper conductor (FRLS) alongwith conduit shall be measured as one unit length including taking down old UNSV submain wiring complete all as specified and as directed.
M&L in repairs sub main wiring with PVC insulated and unsheathed 2 x 4 Sqmm signle core multistandered copper conductor cable (FRLS) passing through in and including PVC conduit surface on walls with all required accesries of conduit ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrubed surface, incl 4 sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note. Two runs of cable 4 Sqmm (FRLS) and One run of 4 Sqmm copper conductor (FRLS) alongwith conduit shall be measured as one unit length including taking down old UNSV submain wiring complete all as specified and as directed.
S&F Vertical Distribution Board, double Door, suitable for and including 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Note: Rate are deemed to be included for 100 Amps MCCB in the quoted rate
S&F copper 20 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test Each Point all as specified.
S&F single Each Pointed air termination Copper rod 12mm dia, 300 mm long
M&L for Test Each Point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test Each Point completed all as specified.
M&L for Point wiring (Concealed) using approved colour coding as per IS Red/Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FR LSH cable 1100 Volts grade ISI 694 marked with valid CML No. in and including In stove enamelled Steel(fire/flame proof) Conduit concealed conduit of dia not less than 20mm and conduit accessories ISI marked for wall/roof /floor etc siutable for switch fire/flame proof rotary type with termination box in LM6, 16A, single pole 250V including PVC insulated multi stranded copper conductor FRLSH 1.5 sqmm nominal cross sectional area single core FRLS H cable as earth continully conductor to commonearth and connecting to earrth dolly complete all as specified and directed for the follwing (a) One light Each Point controlled by one, one way switch
S & F flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as directed.
S&F LED light fitting 1x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
M & L in replacement Earthing complete with copper earth plate electrode 60 cm x60cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal/hard/dense ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers/brazing(as directed by Engineer in Charge) all as shown in electrical plate No. 3 connected to earthing test Each Point all as specified or indicated including testing on, complete all as specified and directed. Note : Rates are deemed to be included for necessary earth work , earth pit with RCC cover of size 300X300 x25 mm etc complete all as specified and as directed.
S&F in repalacement Decorative Strip Light LED ROPE for indoor & outdoor (water proof) with driver (20 mtr in lenght) and complete all as specified and as directed.
M&L for Earthing complete with Chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 32x6 mm strip, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth strip 50x6mm strip means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 3 connected to earthing test Each Point all as specified or indicated including testing on completion, Note : Rates are deemed to be included for necessary earth work, earth pit with RCC cover of size 300X300x25mm etc., complete all as specifed and as directed.
S&F ESE lightening Arresters (protection system ), having arrester length minimum 1 meter, Colour - steel, radius minimum 107 meter for Bldg as per site requirement including GI pipe 40 mm dia or suitable size and length and complete all as specified and as directed.
S&Fin repair of sheet metal enclosure SPN with a two pin earth plug and socket with metal cladd top and one MCB,SP 20amps capacity complete all as specified & directed.
S & F in repairs Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth, complete all as specified & directed.
M & L for detecting fault of existing fire alarm system of with wire/ wireless complete and rectified same, check the faulty Circuit, Control Panel, Alarm/Hooter, call bell etc Completely and rectified the fault and testing on site of circuit complete all as specified and directed. Note: Repair/ replacment of minor space part/ defective items will be deemed to be included in the quoted rate above.
M & L for in replacement of PCB of BLDC fan of any type complete all as specified & directed.
M & L for replacement of BLDC fan bearing of any capacity, type size complete all as specified & directed.
Note for all items:- Making good the distrurbed surface and matching with existing surface of wall is not done Satisfactorily, the panelty as Rs:100/Each unit will be deducted by department. NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
M/S KAUTILYA GARG (BID ID -3410506)
Rajesh Enterprises (BID ID -3401896)
Nikhat nirman (BID ID -3410435)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .