Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹41.1 L+₹2.3 L (5.92%)Rejected-AOC KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹41.2 L+₹2.4 L (6.05%)Rejected-AOC HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹41.3 L+₹2.4 L (6.29%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹41.4 L+₹2.6 L (6.64%)Rejected-AOC SF6 10 SF6 10 SUBHASH PARK SHOPPING HARNI ROAD SANGAM CHAAR RASTA VADODARA 390006 | VADODARA | VADODARA | GUJARAT | 390006 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
30 Dec 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVISION AND ENHANCEMENT OF APPROACH TO 69 ACV SQN ARAMBHADA, DHQ15 OKHA UNDER GE I CG PORBANDAR.
2022_MES_568537_1
8817
Open Tender
Civil Works
Item Rate
180 days
OKHA
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹72,000
Yes
7 Feb 2023
10 Dec 2022
31 Dec 2022
10 Dec 2022
30 Dec 2022
24 Dec 2022
Amount
SCHEDULE 'A'
Surface excavation n.exc 30 cm deep averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Hard/Dense soil all as specified.
Removing excavated material exc 50m but n exc 100m and depositing where directed at a level n.exc 1.5m above from the starting point as in soil complete all as specified.
Returning, filling in, including spreading,levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of Brick work built in cement mortar pavings in ground floors
Labour only for Fixing of walling of precast PCC solid block masonary in PCC (1:3:6) type C1 built in CM (1:6) bonded and solidly hearted all specified .
Rolling and consolidation of surfaces in with power roller of 8 to 12 t capacity power roller including filling up depression which occurred during rolling complete all as specified and directed.
Dismantling of Precast concrete Interlocking paver block of any size,discription, pattern laid dry complete all as specified and directed.
Laying only Machine pressed precast concrete interlocking paver block any shape and size
M&L for walling of precast PCC solid block masonary in PCC (1:3:6) type C1 built in CM (1:6) bonded and solidly hearted complete all as specified and directed.
M&L for Plain Cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in foundation ,sub base complete all as specified and directed.
M & L for rendering 15mm thick in CM (1:4) on fair faces of brick work.or concrete surfaces finished fair and even with out using extra cement.complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished surfaces of concrete complete all as specified.
Use & waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished surfaces of concrete complete all as specified.
M&L for Mild steel TMT CRS bars 10mm dia and over cut to length, bent to shaperequired, including cranking,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT CRS bars 5mm dia and over upto 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for RCC M-30 (using 20mm graded stone agg) as in foundation, including rafts, footings, foundation beams, plinth beams; bases for columns,etc.,basement slabs, under reamed piles and mass concrete, all as specified.
M&L RCC M-30 (using 20mm graded stone agg) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
Use & waste of form work to edges and sides of slabs such as cover slabs and similar work: not exceeding 200 mm thick(Horizontal or sloping with rough finished surfaces of concrete complete all as specified and directed.
M& L for Reinforced cement concrete 1:2:4 type B1 using 20mm grade stone aggregate as in cover slabs complete all as directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.
Material & labour for Cement concrete type D- 2, 1:4:8(40mm graded aggregate) 100 mm thick over a prepared subgrade with coarse and fine aggregate inclneccessary formwork finishing etc complete all as specified and as directed.
Material & labour for 10 mm thick sand layer over DLC layer for cushion to polythene sheet complete all as specified and directed.
Material & labour for providing 400 micron thick ploythene film white/light colour over DLC complete all as specified and directed.
Material & labour for 150 mm thick Cement concrete work in pavement hard-standing of flexural strength 40 kg/per square centimetre in field as specified complete as specified and directed
Supply only polyester triangular synthetic fibres 6/12mm long with circum circle diameter 30-35 micron desgined for melting point 240 -260 degree celsius having specific gravity 1.34 to 1.4 Recron 3S manufactured by M/s Reliance Industries Ltd Mumbai or M/s Finolex Industires Ltd or equivalent as secondary reinfocement in all type of concrete @0.25% by wt of cement complete. (@1.0 Kg per cum of PQC) complete all as specified and directed.
Finishing top concrete pavement by brooming while concrete is green complete.
M & L for forming 20mm thick and 150 mm deep Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete
M & L for forming Contraction (Dummy) joints 65mm deep x 10mm wide,filled with sealing compound→ for forming 10mm thick and 65mm deep (dummy) joints complete all as specified and directed.
M & L 110 mm bore PVC (SWR) pipes single socketed, of any length laid as in trenches ,floor ,weep holes all as specified and directed
Supply and laying Reinforced concrete pipes, class NP2, 150 mm dia laid and jointed complete with collars complete all as specified and directed.
M&L for approved earth or Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, rolled , levelled and rammed including watering
M & L for painting lines,dashes,arrowes,letters,marking of 2 mm thick on new surface or previously treated road surface with hot applied retro reflective thermoplastic road marking paint(white/golden yellow) confirming to MORTH (clause 803.4) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 degree Centigrade including cleaning and drying the existing road surfaces to ensure dust,oil grease and moisure free surfaces before applying paint complete all as specified
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade
Sand filling under floors including watering and consolidation
M & L for hard core (broken stone or boulders) of guage n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M& L for Pre-cast cement concrete 1:3:6 type C1 using 20mm grade stone aggregate as in kerbs set in cement mortar 1:6 with plain fair faces,including chamfers,weatherings,throating etc., complete all as directed.
M & L for providing chequered cement concrete tiles with mixture of white and grey cement in equal proportions and no pigment 300 mm x 300 mm x 25 mm thick jointed and pointed in neat cement slurry in floors ,over & incl. 15 mm screed in CM 1:6 as specified
M & L for PCC in (1:3:6) type C-2 (using 40mm graded stone aggregate) 75mm thick as in Sub base etc. complete all as specified and as directed.
M&L for Cement concrete 1:2:4, type B1(using 20mm graded aggregate ) in edging, coping ,channels necessary form work and finishing of exposed surfaces of concrete as specified.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Preparation for surfaces of any description over 10cm width or girth not otherwise describedand applying two coat synthetic enamel paint over a coat red oxide on steelm surfaces. complete all as specified and directed.
Preparation for surfaces of any description over 10cm width or girth not otherwise describedand applying two coat synthetic enamel paint over concrete suface complete all as specified and directed.
S&F Rolled sections as in rafters / purlins where connected to common rafters etc conforming to Fe-410(W) (Gde-E 250) complete all as specified and directed.
S&F for compound girder / single stanchions, built up of one beam or channel section with one plate etc conforming to Fe-410(W) (Gde-E 250)complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified.
M&L for Plain cement concrete type B1, 1:3:6 (20mm graded stone aggregate) as bed plates to vertical steel posts, etc including necessary form work complete all as specified and directed.
JAY BHARAT METAL SUPPLIERS
roxy enterprise
M/S. P.M GODHANIYA
AUM STRUCT BUILD PVT LTD
K K Construction Co
Harsh Infrastructure
Nitesh Enterprise
SURESH ELECTRICALS
shree chamunda enterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .