GEMC-511687778776497
Awarded to PSI ENGINEERING SYSTEMS PRIVATE LIMITED
₹69.7 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| As per description at Sl. No. 2.1.2.5 of pg. no. 2 of tech. spec i.e. Accessories - Filled oxygen cylinders | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 33 Nos | 19,098 | 630,234 |
| As per description at Sl. No. 4 d. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Erection Hardware - Impulse Line Drain valve | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 39,495 | 39,495 |
| As per description at Sl. No. 2.1.1 of pg. no. 2 of tech. spec i.e. Oxygen dosing skid - including oxygen cylinders mounted on each skid | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 2 Nos | 2,137,016 | 4,274,032 |
| As per description at Sl. No. 2 b. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Solenoid Valves - Coil - single or double coil type | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 39,815 | 39,815 |
| As per sl. No. 1.2 of pg. no. 4 of tech. spec. i.e. Supervision of erection and commissioning - LUMP SUM DAILY CHARGES FOR ENGINEER | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 4 Days | 6,499 | 25,996 |
| As per description at Sl. No. 2.1.2.6 of pg. no. 2 of tech. spec i.e. Accessories - Rack to hold 33 filled oxygen cylinders | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 Nos | 58,412 | 58,412 |
| As per description at Sl. No. 4 e. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Erection Hardware - Impulse Line fittings | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 51,214 | 51,214 |
| As per description at Sl. No. 2.1.2.1 of pg. no. 2 of tech. spec i.e. Accessories - Injector Assembly | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 4 Nos | 48,158 | 192,632 |
| As per description at Sl. No. 3 a. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Gauges - Pressure Gauge | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 47,250 | 47,250 |
| As per description at Sl. No. 2.1.2.7 of pg. no. 2 of tech. spec i.e. Accessories - Compression fittings | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 35 Nos | 5,853 | 204,855 |
| As per description at Sl. No. 4 f. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Erection Hardware - Impulse Pipe | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 35,542 | 35,542 |
| As per description at Sl. No. 2.1.2.2 of pg. no. 2 of tech. spec i.e. Accessories - 15 NB, SS 316, 18 BWG tubing for oxygen dosing | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 200 Meters | 1,421 | 284,200 |
| As per description at Sl. No. 4 a. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Erection Hardware - Transmitters Manifold | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 5,353 | 5,353 |
| As per description at Sl. No. 1 a. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Electronic Transmitters - Pressure | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 148,523 | 148,523 |
| As per description at Sl. No. 4 g. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Erection Hardware - Copper , SS Tube | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Meters, Qty as mentioned in item description | 94,209 | 94,209 |
| As per description at Sl. No. 2.1.2.3 of pg. no. 2 of tech. spec i.e. Accessories - SS 316 Tube fittings --tees | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 10 Nos | 6,155 | 61,550 |
| As per description at Sl. No. 4 b. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Erection Hardware - Impulse Line Root , Source valve | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 22,747 | 22,747 |
| As per description at Sl. No. 1 b. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Electronic Transmitters - Flow Transmitter - MASS FLOW CONTROLLER | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 230,576 | 230,576 |
| As per description at Sl. No. 4 h. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Erection Hardware - Fittings for Copper, SS Tube | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Meters, Qty as mentioned in item description | 357,892 | 357,892 |
| As per description at Sl. No. 2.1.2.4 of pg. no. 2 of tech. spec i.e. Accessories - SS 316 Tube fittings --90 elbows | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 10 Nos | 5,351 | 53,510 |
| As per description at Sl. No. 4 c. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Erection Hardware - Impulse Line Isolation valve | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 39,495 | 39,495 |
| As per description at Sl. No. 2 a. of pg. no. 3 of tech. spec i.e. Mandatory Spares - Solenoid Valves - Complete Solenoid Valve Assembly | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 UOM is Nos, Qty as mentioned in item description | 50,179 | 50,179 |
| As per sl. No. 1.1 of pg. no. 4 of tech. spec. i.e. Supervision of erection and commissioning - LUMP SUM CHARGES PER VISIT FOR ENGINEER - EXCEPT DAILY CHARGES | PSI / OXYGEN DOSING SYSTEM | HSN not specified by seller | 1 Visit | 24,999 | 24,999 |