Loading…
Loading…
Tender ID
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
16 Mar 2026, 6:00 pmClosed
DGVCL - Raipipla Division office
Tender for the work of Erection & Maintenance of HT/ LT Line & Transformer Centre of Rajpipla-1 SDN (also in any other sdn of Rajpipla Dn if required) for SI and other Scheme under Rajpipla Division
284247
E-188/25-26
Open
Electrical Works
Works
Narmada
2 documents required · 2 mandatory
₹1,180
DGVCL
₹5,000
9 Mar 2026
9 Mar 2026
9 Mar 2026
16 Mar 2026
9 Mar 2026
ITEM CODE Details of Works Qty Unit Amount
STRINGING OF 100MM2 ACSR/100MM2 AAAC CONDUCTOR FOR LT LINES INCLUDING COND
FIXING OFINSULATORS, BINDING JUMPERING ETC. PER
STRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES INCLUDING FIXING OF COND
INSULATORS, BINDING JUMPERING ETC. PER
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OF AB SWITCH, HG
FUSES, TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF
METERS 270 KGAND PSC POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROMSTORES TO SITE, FIXING OF CHANNELS,
32 9926000032 SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTI-CLIMBING No. 10662
DEVICES,DANGER BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SETS AND EARTHING.
DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITH TRANSFORMER)
35 9926000035 WITH CREDITING OF FABRICATION & TRANSFORMER AT STORE & STACKING OF POLE No. 3975
SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITHOUT
36 9926000036 TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE & STACKING OF POLE No. 2701
SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND TO
PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP,
38 9926000038 FIXING OF CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER KM 12330
WIRE AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, BINDING TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS
REQUIRED & DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, BINDING TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS
REQUIRED AND DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM INCLUDING FITTING
OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND TO
PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING THE OLD MATERIAL TO
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC POLE(WITHOUT
43 9926000043 TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE AND STACKING OF POLE No. 2828
SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC POLE(WITH
44 9926000044 TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE AND STACKING OF POLE No. 5332
SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES AND FABRICATION TO DEPARTMENTAL STORE
HT,LT &TC Revised as per Letter No DGCS/1408/01/2025 Dt: 27-01-2025
Maintenance Revised as per Letter No DGCS/1410/01/2025 Dt: 27-01-2025
UG Cable Revised as per Letter No DGCS/1411/01/2025 Dt: 27-01-2025
ITEM CODE Details of Works Qty Unit Amount
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM AND CREDITING FITTING
OF ALL ACESSARIES AND FABRICATION TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM AND CREDITING
FITTING OF ALL ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM AND CREDITING
FITTING OF ALL ACESSARIES TO DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR 11/22KV COND
& LT LINES INCLUDING FIXING OF INSULATORS, BINDING JUMPERING ETC. PER
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES INCLUDING , BINDING COND
JUMPERING ETC. PER
LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR METER. (METER WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE REPLACEMENT OF DTR METER AND OLD METER SHOULD BE
CREDITED TO SDN STORE. (METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR METER CONNECTION. (CT COIL PER
WILL BE PROVIDED BY DGVCL) CT
LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR DTR METER CONNECTION AND
55 9926000055 OLD CT SHOULD BE CREDITED TO SDN STORE. (CT COIL WILL BE PROVIDED BY 126
LABOUR CHARGE FOR FIXING OF MMB FOR DTR METER (MMB WILL BE PROVIDED BY
LABOUR CHARGE FOR REPLACEMENT OF DTR METER BOX. (METER WILL BE PROVIDED
PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE COPPER CABLE 3.5 METER (CABLE
TO BE PROVIDED BY AGENCY)
LABOUR CHARGE FOR PROVIDING/RECONNECTION OF TERMINAL CONNECTION WITH TERMI
PROPER SIZE OF LUGS. (LUGS COST IS BORNE BY AGENCY) NATIO
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH DETAIL SURVEY OF
DEFECT IF ANY. A DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN PRO-FORMA
60 9926000060 REPORT SHOULD BE SUBMITTED TO SDN OFFICE.(* ONLY IF ALL PARAMETER OF 60
VOLTAGE, CURRENT & LOAD AS SHOWN IN PER-FORMA IS FILLED) AS PER THE
INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH DETAIL SURVEY OF
DEFECT IF ANY. A DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN PRO-FORMA PER
REPORT SHOULD BE SUBMITTED TO SDN OFFICE. (DULY FILL PER-FORMA IN FAULT DTR
CONDITION IN WHICH READING PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING METER BOX, PROVIDING & FIXING OF 1.5SQ
62 9926000062 MM SINGLE STRAND 10 CORE ARMOURED COPPER CABLE (3.5METER), TERMINATION IN No. 2726
METER & COIL ETC.(METER, METER BOX, C.T./P.T. COIL WILL BE PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING METER BOX, TERMINATION IN METER &
63 9926000063 COIL ETC. (WITHOUT 10CORE COPPER CABLE) (METER, METER BOX, C.T./P.T. COIL No. 886
WILL BE PROVIDED BY DGVCL)
Binding of messanger Conductor at with a distance not more than 0.75 mtr with 6 turns
minimum on XLPE Cable with single strand binding wire (including cost of binding wire)
TOTAL ESTIMATED AMOUNT OF SCHEDULE B1
1 9924000001 Cutting of Tree branches surounding HT/LT line 57
Replacement of old jumpers & providing new double jumpers with 8" binding & capsuling
with PVC pipe etc
3 9924000005 Support pole for Stay PSC/STP/RSJ No. 633
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No. 18
5 9924000007 Pin binding of conductor 11/22kv Pin insulator per pole in costle area with cleaning . No. 41
6 9924000008 Pin binding of conductor LT shakel insulator No. 14
HT,LT &TC Revised as per Letter No DGCS/1408/01/2025 Dt: 27-01-2025
Maintenance Revised as per Letter No DGCS/1410/01/2025 Dt: 27-01-2025
UG Cable Revised as per Letter No DGCS/1411/01/2025 Dt: 27-01-2025
ITEM CODE Details of Works Qty Unit Amount
7 9924000009 Replacement of one/both disc.insulator at strain pole No. 161
8 9924000010 Replacement of LT shackle insulator at cut point No. 31
9 9924000011 Refixing of V cross Arm No. 61
10 9924000012 Replacement of V cross Arm No. 210
11 9924000013 Refixing of Top fitting in proper position No. 41
12 9924000014 Replacement of Top fitting No. 51
13 9924000015 Replacement of LT cross Arm No. 105
14 9924000016 Providing DO fuse on DP with carting & jumpuring(ONE DO FUSE) No. 243
Numburing of pole with paint by preparing back ground of one colour and have
lettering(height 3" * width 0.5") using stensil
16 9924000018 Fixing of MMB(1PH.) at consumer end No. 86
17 9924000019 Fixing of MMB(3PH.) at consumer end No. 128
18 9924000020 Replacement of (1ph.) meter for Urban area No. 51
19 9924000021 Replacement of (1ph.) meter for Rural area No. 74
20 9924000022 painting consumer no. on MMB (Urban) (with letter size height 40mm* width 8mm) No. 11
21 9924000023 painting consumer no. on MMB (Rural) (with letter size height 40mm* width 8mm) No. 19
22 9924000024 Replacement of deteriorated Single phase Service line No. 93
23 9924000025 Fixing of new dist. Box with complete wiring including clamps,nut bolts etc. No. 816
24 9924000026 Reparing of guarding involving reshaping of bearer wire cross lacing binding etc. R Mtr. 25
25 9924000027 Painting of steel fabricated material of RSJ DO DP structure with paint No. 2406
Painting of steel fabricated material of RSJ pole mounted transformer double pole
structure with paint
27 9924000029 Painting of steel fabricated material of RSJ single pole with paint No. 902
28 9924000030 painting of steel fabricated material of PSC Single pole (HT line) with paint No. 135
29 9924000031 painting of steel fabricated material of PSC DO DP double pole with paint No. 362
painting of steel fabricated material of PSC double pole at pole mounted transformer with
31 9924000033 Providing line seperater single phase No. 11
32 9924000034 Providing line seperater three phase No. 31
33 9924000035 Replacement / Providing of stay insulator along with adjustment of tension in stay wire No. 276
Replacement of deteriorated /providing LT dist. Box with new up to 100KVA capacity &
crediting it to store.
Replacement of deteriorated /providing LT dist. Box with new above 100KVA capacity &
crediting it to store.
36 9924000038 Adjustment of tension in stay wire No. 158
37 9924000039 Refitting of LA No. 31
38 9924000040 Converting pin point to Shackle point including dismentaling & restringing etc. 2232
39 9924000041 replacement of 11KV Pin insulator with providing new double pin binding No. 60
replacement of 22KV Pin insulator by new 11kv pin insulator with spares & providing new
double pin binding
41 9924000043 Providing 11kv double disc insulators with binding & restringing No. 161
42 9924000045 Replacement of existing 11kv conductor (all size) with new double pin binding 4354
43 9924000046 Plumbing of PSC Pole with straightening at pin point No. 287
44 9924000047 Plumbing of PSC Pole with straightening at tension point No. 373
45 9924000048 Plumbing of tilted DP structure (PSC/RSJ/STP) with refilling of stone Murrum etc. No. 816
Providing new 11kv AB /GO switch with fabrication and insulated colour code jumper,
binding, lugs etc
Replacement of old 11kv AB /GO switch with providing new insulated jumper, binding,
48 9924000052 Providing cage type loop guard in verticle LT line with using PVC reel insulators etc 53
Labour charges for replacement /providing of MMB & service with all accessories for three
phase connection
Labour charges for replacement /providing of MMB & service with all accessories for single
phase connection
Dismentalling of existing Dist.X'mer center(RSJ /STP POLE) 25/63/100/200 KVA with all
fabrication & creditig the old material to store
52 9924000060 Dismentaling & removing of service line from pole & crediting to S/dn (1 ph.) No. 111
53 9924000061 Dismentaling & removing of service line from pole & crediting to S/dn (3 ph.) No. 205
54 9924000062 Reconnection of service line complete with PVC cable (1 Ph) No. 244
55 9924000063 Reconnection of service line complete with PVC cable (3 Ph) No. 328
Providing spiral type earthing by G.I. NO 8(weight 2kg -5mtr in length) with salt and coal
56 9924000064 10kg each, including pvc rigid pipe 20mm dia( 1.5mtr length) to pass exposed part of G.I. No. 816
wire at consumer end with all materials, earth resistance should be less than 2 ohms
HT,LT &TC Revised as per Letter No DGCS/1408/01/2025 Dt: 27-01-2025
Maintenance Revised as per Letter No DGCS/1410/01/2025 Dt: 27-01-2025
UG Cable Revised as per Letter No DGCS/1411/01/2025 Dt: 27-01-2025
ITEM CODE Details of Works Qty Unit Amount
Providing and fixing of signle core 1.5 sq mm single strand copper insulated cable with
cable nail clip for spiral type earthing at consumer end. The end of G.I. no 8 is to be
connected by connector with copper cable of which other end shall be connected to the per
earth terminal of meter box. This item shall be used in location where there is more meter
distance between earth terminal and earthing terminal of meter. (All materials supplied by
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of cross arm, LT shackle insulator etc.
for fixing of messenger wire and inclusive of dismantling charge of existing bare
58 9924000065 conductor and crediting in to store & dismentaling of service line from LT bare conductor KM 8922
and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer in
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM including fitting of all
acessaries i.e. special design suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of dismantling charge of existing
59 9924000066 bare conductor and crediting in to store & dismentaling of service line from LT bare KM 22303
conductor and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of cross arm, binding to pin
60 9924000067 insulator,preparing shackle point,jumpers etc. and inclusive of dismantling charge of KM 44608
existing bare conductor and crediting in to store complete as required & directed by
Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of cross arm, binding to pin
61 9924000068 insulator,preparing shackle point,jumpers etc. and inclusive of dismantling charge of KM 55019
existing bare conductor and crediting in to store complete as required & directed by
Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM including fitting of all
acessaries i.e. special design suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of dismantling charge of existing
62 9924000069 bare conductor and crediting in to store & dismentaling of service line from LT bare KM 15613
conductor and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer in
63 9909000001 Carting of PSC poles at site No 217
64 9909000021 Carting of RSJ poles at site No 435
TOTAL ESTIMATED AMOUNT OF SCHEDULE B2
1. DGVCL will provide key material like M.S. materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc. to the contractor.
2.All fabricated items shall be fabricated as per DGVCL approved drawing and by welding rods confirming to the
relevent ISI specification and as directed by Engineer in charge.
3.Necessary electricity connection for fabrictated items shall be provided by DGVCL on payment of required charge
for connection & electricity bill of the same shall be paid by the agency.
4.All the rates are inclusive of PF and Exclusive of GST applicable time to time.
5.All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles & steel fabricated materials
of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ poles & steel fabricated
materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver paint) is to be
properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC poles.
Total of B1 & B2 is Rs. TOTAL
Executive Engineeer (O&M)
DGVCL,Rajpipla Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1 E 188 Tender copy.pdf
E 188 schedule A.pdf
3 E 188 Erection and Maintainance New schedule B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .