Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr Quoted ₹2.1 Cr | L1 | Accepted-AOC accept |
| 2 | L2₹2.9 Cr+₹77.9 L (37.6%)Rejected-AOC 0 MATADIN KAKRAHI KAKRAHI BHARTHANA ETAWA ETAWAH UTTAR PRADESH 206242 | ETAWAH | UTTAR PRADESH | 206242 | ₹2.9 Cr+₹77.9 L (37.6%) | L2 | Rejected-AOC accept |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical HIMACHAL PRADESH | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2.1 Cr
EMD Value
₹2.4 L
Closing Date
17 Sept 2021, 11:00 amClosed
EE
Jal Shakti Division Dehra
Const Intake structure desilting tank thrust block OHSR laying jointing and testing of rising main etc
2021_HPIPH_51889_1
DHR-KNG02-728
Open Tender
Civil Works
Item Rate
730 days
Dehra
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,500
EE Dehra
₹2.4 L
Yes
10 Jan 2022
3 Sept 2021
17 Sept 2021
3 Sept 2021
17 Sept 2021
3 Sept 2021
Amount
Construction of RCC over head tank following cap., with 10.00 mtr stagging height from ground level to bottom of dome slab comprising of inlet, scour & over flow pipes as per details given below from ground level to tank including bends of requried degree, confirming to relevants code RCC stair case i/c G.I pipe railing 45cms. wide of usual height as per site requirement, SFRC manhole cover of 500mm dia and weight of frame and cover should not be less than 40 kg., ventilator at top dome with minimum opening of 45x450cms, water level indicator including floats and measuring gauge, lightening conductor with earthing arrangement etc. The RCC over head reservoir shall include randering/plastering of the uneven exposed surface, two coats of snowcem paint and any other component required for the completion of the job to the entire satisfaciton of Engineer-in-charge. The offers shall also include details structural drawing/ design calculations to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site. The offer shall also include the cost of providing and fixing of GMS/ MS pipe, fittings complete including duck foot bends, puddle collars, expansion joints etc connecting with rising main & distribution main with required length from the edge of foundation and any other component required for the completion of job upto the entire satisfaction of Engineer-in-charge. ( Dia of pipe arrangement:- Inlet pipe 80mm dia, out let pipe 80mm dia and Scour pipe 80mm dia)
OHSR 10000 Ltr Cap.
Excavation in foundation, trenches etc. in earth work in all kinds of soil lift upto all height, stacking the excavated soil not more then 3 mtrs. clear from the edge of excavation & then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming & watering and then disposing of all surplus excavated earth as directed within all leads and lifts.
Chieselling work 50% soft rock & 50% hard rock
Pick work 50% jumper work 50%
Providing and laying cement concrete 1:4:8(One cement :Four sand : eight graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work centring & shuttering in foundation and plinth within all leads and lifts.
Providing and laying cement concrete 1:3:6(One cement :three sand : six graded stone aggregate 40mm nominal size and curing complete excluding the cost of centering & shuttering in foundation and plinth within all leads and lifts.
Providing and laying cement concrete work 1:2:4 (One cement : Two sand : Four graded stone aggregate 20mm nominal size and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
Suspended floor, roofs landing and shelves and their supports balconies beams girders bressumers and cantilevers upto floor two level within all leads and lifts.
Providing and laying cement concrete 1:1.5:3 (One cement:one & half sand:three graded stone aggregate 20mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-.
Foundation, footing bases of columns and the like and mass concrete within all leads and lifts .
Wall (any thickness but not less than 0.10 mtrs.thickness) attached pillasters, buttresses plinth & string courses etc. from top of foundation level upto floor two level within all leads and lifts.
Column, pillars, posts & struts upto floor two level.
Lintels, beams girders bressumers and cantilevers.
Providing and laying cement concrete 1:5:10(1cement :5 Sand:10 graded stone aggregate 40mm moninal size) with 15% plums & curing complete excluding the cost of form work in Retaining/wall & Beast/walls, the size of plums shall usually be 150mm to 300mm, as per HPPWD specification as per direction of Engineer in charge within all leads and lifts.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering, strutting and propping etc. with wooden battons and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4.00mtrs. and removal of the same for in-situ-reinforced and plain concrete work in:-
Vertical surface such as walls (any thickness) partitions and the like including attached pillasters,buttresses, plinth and string courses and the like within all leads and lifts.
Flat surfaces such as soffits of suspended floor, roofs, landings and the like floor etc. upto 20cm thickness within all leads and lifts.
Sides and soffits of beam, beam haunching, cantilever and bressumers and lintels not exceeding 1 mtr. in depth in all heights from floor within all leads and lifts.
Column, pillars, posts and struts etc in square or rectanguler in plain and the like within all leads an dlifts complte in all respect.
Providing tor steel reinforcement for RCC work including bending, binding and placing in position complete upto floor two level within all leads and lifts.
Steel work in single section i/c cutting, hoisitng and fixing in positin etc. in RS joists, Channels, angles, Tees and brackets etc. with in all leads and lifts complete in all respect.
Steel work welded in built up sections, trusses & framed work including cutting, hoisting and fixing in position and applying a priming coat of red paint:- In grating, framed, guards bars, ladders,railing, brackets & similar works within all leads and lifts.
Providing in RCC work smooth finishing of the exposed surface with cement motor 1:3(One cement:Three sand) within all leads and lifts.
Laying in trenches GMS pipe (L/M class) tube fitting (earth work in trenches to be measured and paid for separately) complete within all leads and lifts .
80mm dia
100 mm dia
Boulder filling behing retaining wall under floor within all leads and lifts .
Providing and fixing CI man hole cover with frame having frames size of 500 mm internal dia ( Medium duty). The weight of cover and frame should not be less than 58 Kg with in all leads and lifts complete in all respect.
Providing and fixing of MS cover on chamber with MS sheet of 2.00 mm thickness fixed with angle iron frame of 25x25x3mm having locking arrangement complete with a size of 0.80mx0.80m complete in all respect.
20 mm thick cement plaster in single coat on rough side of bricks /stone masonary for interior plastering up to floor two level including arrises, internal rounded angles chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6 (One cement: Six sand) within all leads and lifts.
Providing and fixing V-nothc 90 degree complete in all respect.
Providing and fixing Alfa Valve complete in all respect.
150mm dia
200mm dia
Providing & fixing of Kirloskar/Leader make Cast Iron sluice valve following dia Class-PN-1.0 with M.S.flange table-5 conforming to IS:14846-2000 latest with uptodate ammendments having seat pressure 10.20Kg./cm2 including nut, bolts and gasket sheet within all leads and lifts.
100 mm dia
125 mm dia
150 mm dia
200 mm dia
250 mm dia
Providing and fixing screwed type cast iron Air valve (single ball type) of Leader make confirming to BIS 1452-90 with upto date ammendments as per class PN 1.00 to withstnd the seat pressure of 11.22 Kg/cm2 in raising main or as of latest ammendments complete in all respect.
25 mm dia
Constructing chamber for sluice valve, with C.I.surface box 100mm top dia,160mm bottom dia & 180mm deep(inside) with chained lid RCC top 1:2:4 mix (One cement : Two sand :Four graded stone aggregate 20mm nominal size)100mm thick foundation concrete 1:5:10 (One cement : Five sand : Ten graded stone aggregate 40mm nominal size) and in side plastering with cement mortor 1:3 (One cemet : Three sand) finished with a floating coat of neat cement including curing complete 600x600x750mm in side size with 150mm thick walls of RCC 1:2:4 )One cement:two sand : four graded stone aggregate 20mm nominal size complete with form work and reinforcement with 6mm bars at not exceeding 150mm centres both ways within all leads and lifts.
Providing and fixing gantry for hoisting and lowering of pumping machienry i/c chain pully block of 5.00 MT as per the approved design and specification as per satisfaction of Engineer-in-Chargewith complete in all respect.
40mm thick cement concrete flooring 1:2:4( One cement:two sand: four graded stone aggregate 20mm nominal size) laid in one layer and finished with a floating coat of neat cement within all leads and lifts.
Providing and fixing MS bolt off size with nuts and washers complete in all respect.
Providing, Laying, jointing and testing of GMSERW with circumferential flanged joint by electrical arc welding (welding thickness shall be equal to pipe wall thickness) of following diamters & wall thickness confirming to IS/ISO:3183-2007 of steel grade L-210 or latest upto date amendments and capable of with standing required test pressure in a random length of 5.5 to 6.5 meters, including manufacturing reducers/tapers, all short pieces, bends etc. as per site requirement made from parent tubes. The laying of pipe shall also include welding of every flanged joint duly welded in three layers( two inner one outer) and all operation such as cutting, welding, jointing, fabrication of bends of required degree, tees etc. and lowering & laying in excavated trenches to ensure required level complete in all respects to the best satisfaction of the Engineer-in-charge (Earth work in trenches and the cost of providing flanges including nuts & bolts & gasket will be measured and paid for seperately). The fabricated bends shall have three or four cuts having its radious not less than five times the dia of pipe. The pipes shall be factory galvanized (Zinc coated both inside and outside) as per relevant IS standards and the damaged portion of the pipes and other specials (if damaged during laying, jointing operation of pipe) made from the parent tube, shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS-814 of Advani Oerlikon/L&T of ISI marked made. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing, DP test of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer-in-charge within all leads and lifts.
250mm dia MSERW pipe T-5, 5.40 mm thickness
250mm dia MSERW pipe T-11, 5.40 mm thickness
Providing and fixing of M.S.flanges joint as per IS:6392-1971 (latest with upto date ammendments) and welding of M.S.flanges with G.I.pipes be done in two layers on both faces to make the joint leak proof (providing and laying of G.I.pipes to be measured and paid for separately). The welding of flanges should be as per IS:816-1969 with electrodes as per IS:814-1991 with required number of nuts and bolts as per IS:1369-1967 & compressed asbestos fibre gasket sheet not less than 3mm in thickness as per IS:2712-1998. The work shall be done as per entire satisfaction of the Engineer-in-charge complete in all respect.
250mm dia MSERW pipe T-5, 5.40 mm thickness
250mm dia MSERW pipe T-11, 5.40 mm thickness
Laying and jointing of HDPE pipe of grade PE 80 following dia and pressure complete in all respect incluidng all fittings and accessories complete in all respect.
250mm dia (OD) 4.00Kg/Sq.cm
225mm dia (OD) 4.00Kg/Sq.cm
200mm dia (OD) 4.00Kg/Sq.cm
180mm dia (OD) 4.00Kg/Sq.cm
160mm dia (OD) 4.00Kg/Sq.cm
140mm dia (OD) 4.00Kg/Sq.cm
125mm dia (OD) 4.00Kg/Sq.cm
110mm dia (OD) 4.00Kg/Sq.cm
Providing and supplying 50mm hydrant including GI riser pipe , 50mm gun metal control valve, 50mm pump connecting nipple, plain concrete grouting for GI tee, connecting riser pipe with sub main incluidng complete set of fitting etc. complete in all respect.
Providing and supplying of duly coupled 75mm HDPE based portable sprinkler pipes( IS: 14151-I marked) to withstand pressure of 3.20 Kg/cm2 complete in all respect.
6mtr long
3mtr long
Providing and fixing 75mm duly coupled bend complete in all respect.
Providing and fixing tee of 75mm x 75mm x 75mm complete in all respect.
Providing and fixing end cap , 75mm complete in all respect.
Submersible Pumping Machinery Phase Ist LIS TRIPAL Supply of submersible pumping set of Kirloskar/Kilburn/Clama/Crompton/KSB/BS make conforming to BIS; 8034-1976 latest suitable for lifting Raw water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
Total Head =65.87 mtr.
Discharge required from each pum = 47.32 LPS
No. of pump required = 2.00 Nos . One as act stand bye
Location of the site of inatallation of machinery = the site is located at a distance of 1.00 kmts from Tripal Railway station by road & 0.200 KM on head load ( for the installation of both machineries.
The Altitude of installation. The altitude of place is 511 mtrs above MSL,Type of current. AC Three phase supply with, Rate Voltage Voltage 415+ 10%,Type of water and its source Raw water from Sump well, Charactristics of water. Ambient Temperature dig.c 20 dig. C,b)Turbidity NTU =113 NTU, c)Hardness 260Mg/Ltrs(as CaCO3) = -,d) PH = 6.5 to 8.5 , e) TDS = 610 , total solid Mg /Ltrs = -,f)Other = -,Depth of sump well= 3 mtr LWL in sump well= 450 mtr. ,Center line level of pump = 450 mtr, Discharge level of highest point = ,Static head in Mrs = 61.91mtrs.,Length of R/Main = 195 mtr.,Dia of Rising main = 350MM dia No of working hours per day = 20.00 Hours,Limit of pump operation. = (-) 15 % (+) 10% of total head,R.P.M. of pumping set.= 2900 RPM ( or to be specified by the tenderer)Test run.= 8 Hours continueously for 7 days
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump of rating 75 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. Make: Aarmation Electric Private Limited/MAS/ELLES
Variable frequency drive starter of 75 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES = 2 No
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens = 1 No
MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release. = 1 No
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments. = 2 No.
incommer MCCB with for proper short circuit capability for both the starters make L&T/Schnieder/ABB = 2 No.
On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc. = 1 No.
Input Choke which should be installed at the input of VFD starter, so that there should be proper protection in case of any voltage surge and distortions in signal = = 1 No.
Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. = 1 No.
Output contactors in the output of VFD to run the pump = 2 No.
Transporatation and Carrage Charges for panel till site = 1 No.
Programmable logic controller with appropriate digital and analog inputs and outputs to give automatic command to star delta and also will get data from Multi function Meter for Current, Voltage, KWH, PF and THD. Make Mitsubishi/L&T/Delta = 1 No.
HMI 7" display with IOT to give on and off command manually and also to show pump running and breakdown status at pump station Make Wientek/Exor/Mitsubishi/Mecon. = 1 No.
Supply of software with license to monitor data at Laptop/Mobile in form of Software and Mobile Application for 3 users = 1 No.
Level Sensor to indicate the water level of tank remotely = 1 No.
Cloud GateWay for Data Cluding to Server = 1 No.
Cable for Communication for Water Level Sensor = 1 No.
Installation and Commissioning = 1 No.
Supply of fixing of doble flanged acctuator cast iron sluice valve heavy size one dia higher tha pump size to delivery of pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS 14846-2000 laest with up to date ammendments having seat pressure of 16.32kg/cm2 complete in all respect. (350mm dia)
Supply of Kirloskar/ Kilburn/Leader make Cast iron double flanged accuator swing check type reflux valve class PN 1.6 having bye pass arrangement ( to be provided on delivery side) of size of one size higher than the delivery size of pump and shall be suitable for withstanding nominal seat presure of 16 Kg/Cm2 as per BIS 5312-1984 Part-I
Supply of Kirloskar/ Kilburn/Leader make Cast iron class PN 1.6 double flanged acctuator swing check type reflux valve having bypass arrangement equal to dia of Risng main i.e. 300mm shall be suitable for withstanding nominal seat pressure of 16 Kg/Cm2 as per BIS 5312-1984 ( Latest edition)
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 16.00 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 10.00 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to 100 BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer).
Supply of standarad make 100 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Suction Pipe 300 mm dia
Delivery pipe 250 mm dia
Common header = 350 mm dia
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Centrifugal Pumping machinery Phase Ist LIS TRIPAL Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB/Mather & Platt/Jyoti/Kirloskar/BE/Maxflow/Beaconweir/Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC( Marrathon) /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below.
Total Head= 48.38 Mtrs. Discharge required from each pump = 47.32 lps of each pump No. of pump required 2.00 set ( one will act as stand by) Location of the site of installation of machinery = the site is located as a distance of 1 Km from Tripal Railway station and 0.200 KM on head load ( for the installation of both machineries) The altitude of installation = 750 MSL Type of current AC three phase supply with freqduency of 75 cycle per second. Rate Voltage 415+ 10%, Type of water and its source Clear water shaft level = 511.50 level of discharge poine = 553.35 Static head = 41.85 Charactristics of water. Ambient Temperature dig.c = 20 degree c. b)Turbidity NTU=50 NTU c) Hardness 260Mg/Ltrs(as CaCO3) = 540 ,d) PH = 6.5 to 8.5 -,e) TDS = 410 total solid Mg /Ltrs = -,f)Other = -,Depth of well assembly= . No of working hours per day = 20.00 Hours, length of Rising main = 720 Rmt. Dia of Rising main = 350 mm Limit of pump operation. in the completem Range of = (-) 75% R.P.M. of pumping set.= 2900 RPM Test run.= 8 Hours continueously for 7 days
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump of rating 55 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. Make: Aarmation Electric Private Limited/MAS/ELLES
Variable frequency drive starter of 55 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLESS = 2 Nos
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens = 1 No
MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release= 1 No
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.= 2 Nos
Incommer MCCB with for proper short circuit capability for both the starters make L&T/Schnieder/ABB = 2 No
On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc.= 1 No
Input Choke which should be installed at the input of VFD starter, so that there should be proper protection in case of any voltage surge and distortions in signal = 1 No
Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. = 1 No
Output contactors in the output of VFD to run the pump = 2 No
Transporatation and Carrage Charges for panel till site = 1 No'
Programmable logic controller with appropriate digital and analog inputs and outputs to give automatic command to star delta and also will get data from Multi function Meter for Current, Voltage, KWH, PF and THD. Make Mitsubishi/L&T/Delta = 1 No
HMI 7" display with IOT to give on and off command manually and also to show pump running and breakdown status at pump station Make Wientek/Exor/Mitsubishi/Mecon. = 1 no
Supply of software with license to monitor data at Laptop/Mobile in form of Software and Mobile Application for 3 users = 1 No
Level Sensor to indicate the water level of tank remotely = 1 No
Cloud GateWay for Data Cluding to Server = 1 No
Cable for Communication for Water Level Sensor = 1 No
Installation and Commissioning = 1 No
Supply of fixing of doble flanged cast steel actuated sluice valve heavy size one dia higher tha pump size to delivery of pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS 1414 API-600 laest with up to date ammendments having seat pressure of 58.00kg/cm2 complete in all respect.
Supply of Kirloskar/ Kilburn/Leader make Cast iron double flanged swing check type reflux valve class PN 1.6 having bye pass arrangement ( to be provided on delivery side) of size of one size higher than the delivery size of pump and shall be suitable for withstanding nominal seat presure of 58 Kg/Cm2 as per BIS 5312-1984 Part-I
Supply of Kirloskar/ Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 5312-1984 ( latest edition) to be provided on Rising main) of size and shall be suitable for withstanding nominal seat pressure of 52 Kg/cm2 (300mm dia)
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cos
On supply side of 3½ core coper cable 120mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 70 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to 100 BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer).
Supply of standarad make 350 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Suction Pipe ---- mm dia
Delivery pipe --- mm dia
Common header = 350 mm dia
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works. (for both machineries)
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Submersible Pumping Machinery Phase 2nd LIS Kuthar Supply of submersible pumping set of Kirloskar/Kilburn/Clama/Crompton/KSB/BS make conforming to BIS; 8034-1976 latest suitable for lifting Raw water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
Total Head =19.07 mtr.
Discharge required from each pum = 21.50 LPS
No. of pump required = 2.00 Nos . One as act stand bye
Location of the site of inatallation of machinery = the site is located at a distance of 6.00 kmts from Jawalamukhi road Railway station by road & 0.200 KM on head load ( for the installation of both machineries.
The Altitude of installation. The altitude of place is 500 mtrs above MSL,Type of current. AC Three phase supply with, Rate Voltage Voltage 415+ 10%,Type of water and its source Raw water from Sump well, Charactristics of water. Ambient Temperature dig.c 20 dig. C,b)Turbidity NTU =113 NTU, c)Hardness 260Mg/Ltrs(as CaCO3) = 540 -,d) PH = 6.5 to 8.5 , e) TDS = 610 PPM, total solid Mg /Ltrs = -,f)Other = -,Depth of sump well= 3 mtr LWL in sump well= 395.47 mtr. ,Center line level of pump = 395.47 mtr, Discharge level of highest point = 409.50 mtr. ,Static head in Mrs = 14.03mtrs.,Length of R/Main = 150 mtr.,Dia of Rising main = 250MM dia No of working hours per day = 20.00 Hours,Limit of pump operation. = (-) 15 % (+) 10% of total head,R.P.M. of pumping set.= 2900 RPM ( or to be specified by the tenderer)Test run.= 8 Hours continueously for 7 days
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump of rating 10 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. Make: Aarmation Electric Private Limited/MAS/ELLES
Variable frequency drive starter of -- HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES = 2 Nos.
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens = 1 No
MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release. = 1 No
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments. = 2 No.
incommer MCCB with for proper short circuit capability for both the starters make L&T/Schnieder/ABB = 2 No.
On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc. = 1 No.
Input Choke which should be installed at the input of VFD starter, so that there should be proper protection in case of any voltage surge and distortions in signal = = 1 No.
Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. = 1 No.
Output contactors in the output of VFD to run the pump = 2 No.
Transporatation and Carrage Charges for panel till site = 1 No.
Programmable logic controller with appropriate digital and analog inputs and outputs to give automatic command to star delta and also will get data from Multi function Meter for Current, Voltage, KWH, PF and THD. Make Mitsubishi/L&T/Delta = 1 No.
HMI 7" display with IOT to give on and off command manually and also to show pump running and breakdown status at pump station Make Wientek/Exor/Mitsubishi/Mecon. = 1 No.
Supply of software with license to monitor data at Laptop/Mobile in form of Software and Mobile Application for 3 users = 1 No.
Level Sensor to indicate the water level of tank remotely = 1 No.
Cloud GateWay for Data Cluding to Server = 1 No.
Cable for Communication for Water Level Sensor = 1 No.
Installation and Commissioning = 1 No.
Supply of fixing of doble flanged acctuator cast iron sluice valve heavy size one dia higher tha pump size to delivery of pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS 14846-2000 laest with up to date ammendments having seat pressure of 16.32kg/cm2 complete in all respect. (250mm dia)
Supply of Kirloskar/ Kilburn/Leader make Cast iron double flanged accuator swing check type reflux valve class PN 1.6 having bye pass arrangement ( to be provided on delivery side) of size of one size higher than the delivery size of pump and shall be suitable for withstanding nominal seat presure of 16 Kg/Cm2 as per BIS 5312-1984 Part-I
Supply of Kirloskar/ Kilburn/Leader make Cast iron class PN 1.6 double flanged acctuator swing check type reflux valve having bypass arrangement equal to dia of Risng main i.e. 300mm shall be suitable for withstanding nominal seat pressure of 16 Kg/Cm2 as per BIS 5312-1984 ( Latest edition)
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 16.00 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 10.00 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to 100 BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer).
Supply of standarad make 100 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Suction Pipe 300 mm dia
Delivery pipe 200 mm dia
Common header = 250 mm dia
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Centrifugal Pumping machinery Phase 2nd LIS KUTHAR Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB/Mather & att/Jyoti/Kirloskar/BE/Maxflow/Beaconweir/Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC( Marrathon) /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below.
Total Head= 77.40 Mtrs. Discharge required from each pump = 21.50 lps of each pump No. of pump required 2.00 set ( one will act as stand by) Location of the site of installation of machinery = the site is located as a distance of 6 Km from Jawalamukhi road Railway station and 0.200 KM on head load ( for the installation of both machineries) The altitude of installation = 750 MSL Type of current AC three phase supply with freqduency of 75 cycle per second. Rate Voltage 415+ 10%, Type of water and its source Clear water shaft level = - level of discharge point = 476.87 Static head = 69.37 Charactristics of water. Ambient Temperature dig.c = 20 degree c. b)Turbidity NTU=50 NTU c) Hardness 260Mg/Ltrs(as CaCO3) = 540, d) PH = 6.5 to 8.5 -,e) TDS= 410 ,f)Other = -,Depth of well assembly= - No of working hours per day = 20.00 Hours, length of Rising main = 450 Rmt. Dia of Rising main = 250 mm Limit of pump operation. in the completem Range of = (-) 75% R.P.M. of pumping set.= 2900 RPM Test run.= 8 Hours continueously for 7 days
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump of rating 40 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. Make: Aarmation Electric Private Limited/MAS/ELLES
ariable frequency drive starter of 40 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES = 2 No
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens = 1 No.
MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release= 1 No
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.= 2 Nos
Incommer MCCB with for proper short circuit capability for both the starters make L&T/Schnieder/ABB = 2 No
On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc.= 1 No
Input Choke which should be installed at the input of VFD starter, so that there should be proper protection in case of any voltage surge and distortions in signal = 1 No
Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. = 1 No
Output contactors in the output of VFD to run the pump = 2 No
Transporatation and Carrage Charges for panel till site = 1 No'
Programmable logic controller with appropriate digital and analog inputs and outputs to give automatic command to star delta and also will get data from Multi function Meter for Current, Voltage, KWH, PF and THD. Make Mitsubishi/L&T/Delta = 1 No
HMI 7" display with IOT to give on and off command manually and also to show pump running and breakdown status at pump station Make Wientek/Exor/Mitsubishi/Mecon. = 1 no
Supply of software with license to monitor data at Laptop/Mobile in form of Software and Mobile Application for 3 users = 1 No
Level Sensor to indicate the water level of tank remotely = 1 No
Cloud GateWay for Data Cluding to Server = 1 No
Cable for Communication for Water Level Sensor = 1 No
Installation and Commissioning = 1 No
Supply of fixing of doble flanged cast steel actuated sluice valve heavy size one dia higher tha pump size to delivery of pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS 1414 API-600 laest with up to date ammendments having seat pressure of 58.00kg/cm2 complete in all respect.
Supply of Kirloskar/ Kilburn/Leader make Cast iron double flanged swing check type reflux valve class PN 1.6 having bye pass arrangement ( to be provided on delivery side) of size of one size higher than the delivery size of pump and shall be suitable for withstanding nominal seat presure of 58 Kg/Cm2 as per BIS 5312-1984 Part-I
Supply of Kirloskar/ Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 5312-1984 ( latest edition) to be provided on Rising main) of size and shall be suitable for withstanding nominal seat pressure of 52 Kg/cm2 (250mm dia)
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cos
On supply side of 3½ core coper cable 120mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 70 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to 100 BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer).
Supply of standarad make 100 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Suction Pipe ---- mm dia
Delivery pipe --- mm dia
Common header = 250 mm dia
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works. (for both machineries)
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
sanjeev kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .