Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹20.3 L
EMD Value
₹40,700
Closing Date
27 Aug 2024, 2:30 pmClosed
OSD HWBF TALCHER
HWBF TALCHER
Annual Maintenance of Air Conditioners, Water Coolers and Refrigerators at HWBF, Talcher
2024_HWB_820900_1
HWBF/TAL/MAINT E/2024/04
Open Tender
Electrical Works
Item Rate
365 days
HWBF TALCHER
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹40,700
6 Sept 2024
13 Aug 2024
28 Aug 2024
13 Aug 2024
27 Aug 2024
14 Aug 2024
14 Aug 2024 - 16 Aug 2024
Amount
UPTO 1.5 TR. WINDOW A/C AND REFRIGERATOR
Bi-monthly servicing of 1.5 TR window a/c units including handling of units, cleaning of air filters within 15days and attending breakdown maintenance both at plant and colony, as per specifications of tender document.
Replacement of a/c compressor/Leak arresting and associated works including supply of refrigerant filter, capillary and refrigerant gas including charging of refrigerant. Compressor shall be supplied by dept. at free of cost.
Fresh Installation including cutting of wall, supply of Aluminium frame and packing, fixing of AC, plastering & painting work to make the wall as good as before & testing.
Installation without cutting of wall, supply of Aluminium frame and packing, fixing of AC, plastering & painting work to make the wall as good as before & testing.
Quarterly servicing of Refrigerators including handling of units and attending breakdown maintenance both at plant and colony, as per specifications of tender document.
Replacement of refrigerator compressor/Leak arresting and associated works including supply of refrigerant filter dryer, capillary and refrigerant(R22/R134/R600) including charging of refrigerant. Compressor shall be supplied by dept. at free of cost.
2 TR / 1.5 TR SPLIT A/C
Bi-monthly servicing of Split a/c units including handling of units, cleaning of air filters within 15days and attending breakdown maintenance both at plant and colony, as per specifications of tender document.
Replacement of compressor/Leak arresting and associated works including supply of refrigerant filter, capillary and refrigerant including charging of refrigerant. Compressor shall be supplied by dept. at free of cost.
Fresh Installation including cutting of wall, fixing of Split AC, plastering & painting work to make the wall as good as before & testing.
WATER COOLER
Monthly servicing of water cooler including cleaning of tank inside and out side once in 15 Days and attending breakdown maintenance both at colony and plant site as per specifications of tender document.
Replacement and installation of compressor/ leak arresting of refrigerant and associated works including supply of refrigerant filter, capillary, refrigerant, and charging of gas. Compressor shall be supplied by dept. at free of cost.
Supply and fixing of High density nitrile rubber thermal insulation tube/ centrally cut of thickness 1 cm for suction and discharge copper tube upto size from 1/4" to 5/8" along with fixing of 3M Duct tape, Silver, Model: 3939 ( 3M Duct tape supply is in contractor's scope)
Supply and installation of following suitable new spares parts in upto 1.5 TR window Acs / Upto 60 liters per hour water coolers as when required.
Fan motor including capacitor(metal, oil filled) and fixing clamps suitable for 1.5TR window ac, 230 V, 1- Ph, 50Hz as when required. Nominal wattage: 100W
Compressor of following specifications for 1.5T window AC: Make and model: Techumseh AW1500 or as per sample Reciprocating type
Fan blade with outer ring, 5 wing, ellen key tight of condenser for window a/c as per requirement for assembled AC
Fan blade with outer ring, 5 wing, ellen key tight of Condenser for window a/c as per requirement for Spencer make, blade should be metallic
Fan blade with outer ring, 5 wing, ellen key tight of Condenser for window a/c as per requirement for Arco make, blade should be metallic
Cooling air blower for Window a/c without motor as per requirement
OEM Air filter Synthetic type for window a/c for Godrej 5034 1.5T / as per sample
Topping up in Split a/c or refrigerator of R-22/R-32/ R-134/R-600 (as when required).
Louver motor for window AC. Make: Mukund/ Annapurna
Universal remote control for Window AC of make Voltas/ Godrej
Compressor reciprocating type for Watercooler as per sample .
Fan motor for water cooler including capacitor(metal, oil filled) and fixing clamps, 230 V, 1- Ph, 50Hz as when required. Nominal wattage: 35W
Fan motor with metal fan blade for water cooler as per sample
PTC strating relay with overload for water cooler as per sample
Push tap cock for water cooler as per sample
Brass Float valve for Usha make water cooler tank. Thread size of 1/2", rod length of 6 inch
Supply and installation of following spare parts in 2 TR/ 1.5 TR Split A/C 's as when required
Rubber Bush for Blower as per sample
Cooling air blower as per sample for split AC without motor.
Indoor blower motor of copper winding and double ball bearing including capacitor(metal, oil filled) and fixing clamps for split AC. Nominal Wattage: 25W
Indoor unit (for replacement of indoor unit of 1.5T split AC), BEE 3 star, evaporator of copper tubing, indoor motor of copper winding and double ball bearing. Provision of remote control unit and temperature display LCD/LED(both set and measured temperatures) shall be present. Remote control with LCD screen shall also be supplied.
Outdoor fan motor of copper winding and double ball bearing including capacitor(metal, oil filled) and fixing clamps as per sample for split AC. Nominal Wattage: 75W
Outdoor fan as per sample for split AC as per sample
Condensor coil(consisting of Copper tubing) for 1.5TR split AC as per sample.
Air filters for Voltas 1.5T/2T or as per sample
Corrugated plastic Drain pipe(for split AC) of half inch inner diameter(Sample of the same shall be submitted for approval before bulk supply)
Louver motor for split AC as per sample.
Universal remote control(with LCD display) for split AC of make Voltas Vectra/Voltas Vertis Elite/Voltas Visionaire/Voltas silver
Outdoor unit (for replacement of outdoor unit of 1.5T split AC), BEE 3 star, condensor of copper tubing, energy star hermetically sealed compressor, outdoor motor of copper winding and double ball bearing alongwith 3.5 mtr. of suction and discharge tubing each, 3.5mtr flexible wire.
Split AC Compressor for Voltas silver 1.5T, Make and model: Highly Rotary SH295RY-C7PUA
Split AC Compressor for Voltas Visionaire 2T, Make and model: Techumseh AW-2000F Reciprocating
Split AC Compressor for Voltas Elite 2T, Make and model: Panasonic Rotary 3 legs 2V38S225AUV
Rotary Compressors for 2T split AC as per sample
Supply and installtion of 2Ton 3 Star Inverter Cassette AC with minimum rated cooling capacity 7000W, 4 way cooling,R32 refrigerant, 100% copper, indoor unit , outdoor unit, accessories all complete and as per technical specification.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks).
Supply and installation of following parts in Refrigerators of upto 310 ltr. as when required
Timer for refrigerator as per sample
Overload relay with PTC starting relay for refrigerator as per sample
Bimetallic thermostat for refrigerator as per sample
Fan motor(for frost free) of copper winding and double bearing for refrigerator as per sample
Heater for refrigerator as per sample
GAGAN BIHARI BISWAL
JYOTI ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .