| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.9 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹75.8 L+₹4.9 L (6.94%)Admitted-Fee/PreQual/Technical/Finance EDAKKANDY MANNIL AVALA P O KOYILANDI TALUK KOZHIKODE DISTRICT | KOZHIKODE | KERALA | 612906 | L2 | Admitted-Fee/PreQual/Technical/Finance | |
| 3 | L3₹76.7 L+₹5.7 L (8.07%)Admitted-Fee/PreQual/Technical/Finance NADAPURAM GRAMA PANCHAYAT POST KALLACHI 673 506 | KOZHIKODE | KERALA | 673506 | L3 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | KAREEM M L2 | K MAJEED L1 | Harikrishnan L3 |
|---|---|---|---|---|---|---|
| 1.00CONSTRUCTION OF SECOND FLOOR | ||||||
| 1.00 | OD96334/2026-2027:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:-cement content shall be as per design mix No seperate payment shall be made for extra cement used. All work above plinth level upto floor V level. | 101.71 | cum | 11,500 ₹11,69,619 | 10,831.28 ₹11,01,606.16 Lowest | 11,800 ₹12,00,130.8 |
| 1.00 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 225.26 | sqm | 900 ₹2,02,732.2 | 847.2 ₹1,90,838.58 Lowest | 941.31 ₹2,12,037.61 |
| 1.00 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 350.3 | sqm | 700 ₹2,45,208.6 | 640.8 ₹2,24,470.96 Lowest | 712.02 ₹2,49,419.18 |
| 1.00 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 407.83 | sqm | 860 ₹3,50,733.8 | 807.45 ₹3,29,302.33 Lowest | 897.16 ₹3,65,888.76 |
| 1.00 | 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and wallsUnder 20 cm wide | 196.99 | metre | 205 ₹40,382.95 | 191.65 ₹37,753.13 Lowest | 212.92 ₹41,943.11 |
| 1.01 | 5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) | 366.05 | sqm | 360 ₹1,31,778 | 336.3 ₹1,23,102.62 Lowest | 373.64 ₹1,36,770.92 |
| 1.01 | 5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) | 44.39 | sqm | 750 ₹33,291 | 692.85 ₹30,754.23 Lowest | 769.82 ₹34,170.77 |
| 1.01 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 13,045.39 | kilogram | 100 ₹13,04,539 | 94.45 ₹12,32,137.09 Lowest | 95 ₹12,39,312.05 |
| 1.01 | 50.6.7.3:Laterate masonry with neatly dressed laterate stone of size 40x20x15 cm or nearest size in cement mortar 1:6 for superstructure above floor two level upto floor five level including all cost of materials, labour charges etc. | 40.3 | cum | 9,350 ₹3,76,823.7 | 8,557.75 ₹3,44,894.44 Lowest | 9,508.61 ₹3,83,216 |
Tender Value
₹78.8 L
EMD Value
₹50,000
Closing Date
22 Sept 2026, 6:00 pmClosed
AE EDACHERI GP
AE EDACHERI GP
Annual Plan-EDACHERY GP 2026-27 CONSTRUCTION OF EDACHERY PANCHAYATH OFFICE BUILDING-IN WARD 13 Pr no.113/27-General Civil Work
2026_LSGD_869316_1
2/AE/EDY/27/26-27
Open Tender
Civil Works - Buildings
Item Rate
90 days
EDACHERI GP
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
Yes
₹50,000
Yes
24 Sept 2026
11 Sept 2026
24 Sept 2026
11 Sept 2026
22 Sept 2026
11 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1CONSTRUCTION OF SECOND FLOOR | |||||
| 1.001 | OD96334/2026-2027:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:-cement content shall be as per design mix No seperate payment shall be made for extra cement used. All work above plinth level upto floor V level. | 101.71 | cum | - | - |
| 1.002 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 225.26 | sqm | - | - |
| 1.003 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 350.3 | sqm | - | - |
| 1.004 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | 407.83 | sqm | - | - |
| 1.005 | 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and wallsUnder 20 cm wide | 196.99 | metre | - | - |
| 1.006 | 5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) | 366.05 | sqm | - | - |
| 1.007 | 5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) | 44.39 | sqm | - | - |
| 1.008 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 13,045.39 | kilogram | - | - |
| 1.009 | 50.6.7.3:Laterate masonry with neatly dressed laterate stone of size 40x20x15 cm or nearest size in cement mortar 1:6 for superstructure above floor two level upto floor five level including all cost of materials, labour charges etc. | 40.3 | cum | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.06 MB
BOQ_1472670.xls
BOQ • 0.35 MB
epay.pdf
Tender Documents • 0.01 MB
viewnit.pdf
Tender Documents • 0.04 MB
viewsbd.pdf
Tender Documents • 11.57 MB
fot.pdf
Tender Documents • 0.01 MB
affidavit.pdf
Tender Documents • 0.01 MB
ip.pdf
Tender Documents • 0.01 MB
priliminary.pdf
Tender Documents • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .