Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L1 | Accepted-AOC Being L 1 | |
| 2 | L2₹13.5 L+₹77,920 (6.14%)Rejected-Finance GARRISON ENGINEER GE NORTH BINNAGURI | JALPAIGURI | WEST BENGAL | 735232 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹13.7 L+₹97,797.50 (7.71%)Rejected-Finance 234 4 JC BOSE ROAD KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance Being L3 |
Tender Value
₹15 L
EMD Value
₹50,000
Closing Date
26 Nov 2020, 6:00 pmClosed
GE North Binnaguri
Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
REPAIR REPLACEMENT OF LT CABLE LT PANELS LT ACBs AND ALLIED WORKS IN MD OTM ACCN OF CENTRAL ZONE AREA UNDER GE NORTH BINNAGURI
2020_MES_384467_2
8701/17/2020-21/02/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BINNAGURI
Class E bi
8 documents required · 8 mandatory
₹500
Yes
GE North Binnaguri
₹50,000
Yes
7 Dec 2020
2 Nov 2020
28 Nov 2020
2 Nov 2020
26 Nov 2020
14 Nov 2020
Amount
SCHEDULE `A' ( ELECTRIFICATION) Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations of poles etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed .
Material and labour for laying well burnt old size bricks, fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Laying only old burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed. Note :- Excavation & Earth work shall be measured and paid separately)
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 80 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed. Note :- Excavation & Earth work shall be measured and paid separately)
Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material and keep serviceable material for reuse in safe custody for any size complete as directed (Excavation/earth work shall be measured & paid separately under relevant item of this schedule)
Supply, laying , jointing and testing LT underground electric power cable XLPE insulated, galvanised steel strip or wire armoured / PVC insulated armoured cable 1100 volts grade,heavy duty with aluminium conductor of cross section area of 16 sqmm 2 core with all fixing and connecting accesoriessuch as aluminium cable lugs, cable glands, nuts and bolts, washer etc laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / GI Pipes shall be measured and paid separately under appropriate items)
Supply, laying , jointing and testing LT underground electric power cable XLPE insulated, galvanised steel strip or wire armoured / PVC insulated armoured cable 1100 volts grade,heavy duty with aluminium conductor of cross section area of 50 sqmm 3.5 core with all fixing and connecting accesoriessuch as aluminium cable lugs, cable glands, nuts and bolts, washer etc laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / GI Pipes shall be measured and paid separately under appropriate items)
Supply, laying , jointing and testing LT underground electric power cable XLPE insulated, galvanised steel strip or wire armoured / PVC insulated armoured cable 1100 volts grade,heavy duty with aluminium conductor of cross section area of 95 sqmm 3.5 core with all fixing and connecting accesoriessuch as aluminium cable lugs, cable glands, nuts and bolts, washer etc laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / GI Pipes shall be measured and paid separately under appropriate items)
Supply, laying , jointing and testing LT underground electric power cable XLPE insulated, galvanised steel strip or wire armoured / PVC insulated armoured cable 1100 volts grade,heavy duty with aluminium conductor of cross section area of 185 sqmm 3.5 core with all fixing and connecting accesoriessuch as aluminium cable lugs, cable glands, nuts and bolts, washer etc laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / GI Pipes shall be measured and paid separately under appropriate items)
Supply, laying , jointing and testing LT underground electric power cable XLPE insulated, galvanised steel strip or wire armoured / PVC insulated armoured cable 1100 volts grade,heavy duty with aluminium conductor of cross section area of 300 sqmm 3.5 core with all fixing and connecting accesoriessuch as aluminium cable lugs, cable glands, nuts and bolts, washer etc laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / GI Pipes shall be measured and paid separately under appropriate items)
Material and labour for Digging out incoming and outgoing cables of any sizes from loop near junction box/ feeder pillar box in tranches, cutting burntout uninsulated portion of cable abd rectify the defect and relaying the XLPE cable under ground aluminium conductor in trenches and returning and filling the excavated soil and connecting the cables with bus bars including provision of lugs as applicable and testing complete all as specified.
Relaying in trenches or passing through pipes , 1100 volts grade , serviceable LT electric power cable UG Cable, of any size / type with and including all fixing and connecting accessories such as aluminium cable lugs, cable gland, nt bolts washers etc complete all as directed. Note :- Serviceable cable obtained from dismantling shallbe reused.
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 63 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 100 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 160 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 200 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 250 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, 400 Amps, Four pole, adjustable, 415 Volts, 36 kA, 50 Hz Icu=100% complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCB in panels etc. MCB, 63 Amps, TPN, 240 Volts, 10 kA, 50 Hz 'C" series complete all as specified and directed
Dismconnecing the existing cable from Panel/ Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint (Epoxy Type) suitable for LT XLPE cable of Size 3.5/4 Core 25 to 50 Sqmm complete all as directed.
Dismconnecing the existing cable from Panel/ Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint (Epoxy Type) suitable for LT XLPE cable of Size 3.5/4 Core 70 to 120 Sqmm complete all as directed.
Supply and fixing in replacement of factory made sheet metal box made out of 2 mm thick MS sheet of size 450 X 300 X 200 mm Bus bar box 3 phase one Neutral 415 Volts with copper busbar of 25X3 mm capacity mounted on hydrograpic PVC insulator with single door hinged shutter and locking arrangement and grouting on wall incl painting with two coated of powder coated paint after necessary preparation of surface complete all as specified & directed.
Supply and fixing of aluminium bus bar of size 400 mm X 40 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and directed.
Supply and fixing of aluminium bus bar of size 600 mm X 20 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and directed.
Supply and fixing in replacement of factory made sheet metal box made out of 2 mm thick MS sheet of size 350(B) X 400(H) X 200(D) mm with single door hinged shutter and locking arrangement for fixing MCCB flashed / grouting on wall incl painting with two coated of powder coated paint after necessary preparation of surface complete all as specified & directed
Supply, installation, testing and commissioning out door type cubical panel board of size (1500 mm (H) x 1000 mm (B) x 600 mm (D)) overall made out of 3.15 mm thick CRCA and MS angle section 50x50x6 mm CPRI approved degree of protection IP-55 and general construction confirming to IS; 13947 on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system (Each door hinged with body at 4 places ) lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which included seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns , provided with suitable gasket to make it dust / vermin proof and general construction confirming to IS:8623/93. the TPN busbar shall be insulated with colour coaded heat shrinkable sleeve through out length of the busbar and shall be mounted on suitable size "F"class insulator at an interval not more than 250 mm. the cubicle incomer MCCB as well as outgoing shall have aluminium TPN extansion links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. the extansion capacity not less than 300 mm long supported on suitable size "F"class insulator. all inter connection between the main busbar as well as outgoing feeder shall be carried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves, Danger Notice Board size as per IE Rule 1956 including PCC foundation of size 0.80m x 0.60m x 1.05m depth (45cm below GL and 60 cm above GL in PCC 1:3:6 type C2 comprising of the following and including taking down of unserviceable panel board from site all as directed. (a) Incomming TPN acopper busbar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulators of non hygroscopic non combustable , all internal connection from main busbar to switch gear etc - 04 Nos (b) Outgoing TPN acopper busbar 300 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulators of non hygroscopic non combustable , all internal connection from main busbar to switch gear etc - 04 Nos (b) Incoming MCCB TPN 200 Amps 16 KA 415 volts, 50 Hz, FP withadjustable thermal magneti c release with Icu = 100 % Icu, neutral adjustmnet 100 % including all fixing accessories with both ends spreader links - 01 No NOTE: Rate of earthwork and PCC are deemed to be inclusive in the unit rate quoted against this item.
Supply, installation, testing and commissioning of factory made sheet metal box made out of 2 mm thick MS sheet of Minimam size 600 X 900 X 200 mm with double door (one side glass and second metal door) hinged shutter and locking arrangement for fixing DBs, KWH Metter etc flashed / grouting on wall incl painting with two coat of powder coated paint over a coat of red oxide primer with and incl fixing/connecting of Meters on insulated board with all accessories and and making good disturbed surfaces of walls with necessary plaster/PCC works complete all as specified & directed including taking down old one.
Supply, installation, testing and commissioning out door type LT Junction box cubical of size (900 mm (H) x 600 mm (B) x 400 mm (D)) overall outer shell made out of 3.15 mm thick CRCA sheet and MS angle section 50x50x6 mm the panel shall be dust and vemin proof, IP65 class protection on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system (Each door hinged with body at 4 places ) lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which included seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns , provided with suitable gasket to make it dust / vermin proof and general construction confirming to IS:8623/93. the TPN busbar shall be insulated with colour coaded heat shrinkable sleeve through out length of the busbar and shall be mounted on suitable size "F"class insulator at an interval not more than 250 mm. the cubicle incomer MCCB as well as outgoing shall have aluminium TPN extansion links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. the extansion capacity not less than 300 mm long supported on suitable size "F"class insulator. all inter connection between the main busbar as well as outgoing feeder shall be carried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves, Danger Notice Board size as per IE Rule 1956 including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches comprising of the following and including taking down of unserviceable panel board from site all as directed. (a) TPN aluminium busbar 200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulators of size 50 mm X 6 mm X 400mm long wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. (b) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Supply, installation, testing and commissioning out door type LT Junction box cubical of size (900 mm (H) x 600 mm (B) x 400 mm (D)) overall outer shell made out of 3.15 mm thick CRCA sheet and MS angle section 50x50x6 mm the panel shall be dust and vemin proof, IP65 class protection on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system (Each door hinged with body at 4 places ) lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which included seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns , provided with suitable gasket to make it dust / vermin proof and general construction confirming to IS:8623/93. the TPN busbar shall be insulated with colour coaded heat shrinkable sleeve through out length of the busbar and shall be mounted on suitable size "F"class insulator at an interval not more than 250 mm. the cubicle incomer MCCB as well as outgoing shall have aluminium TPN extansion links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. the extansion capacity not less than 300 mm long supported on suitable size "F"class insulator. all inter connection between the main busbar as well as outgoing feeder shall be carried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves, Danger Notice Board size as per IE Rule 1956 comprising of the following and including taking down of unserviceable panel board from site all as directed. (a) TPN aluminium busbar 200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulators (b) MCCB TPN 200 Amps 25 KA 415 volts, 50 Hz, FP - 01 No
Material and labour for complete removal of existing paint of external steel surface by scrapping or heating of feeder pillar box / LT panel board and Junction Box of any size and applying two coats of spray painting of 1st quality over a coat of zinc chrome primer including applying filler coat for smooth surface and marking Sub-Station No, Feeder No, Feeding area, and Building with synthetic enamel paint as per existing complete all as specified
Supply & fixing in repairs LED indicating RED lamp, including necessary connection complete all as specified and directed.
Supply & fixing in repairs LED indicating YELLOW lamp, including necessary connection complete all as specified and directed.
Supply & fixing in repairs LED indicating BLUE lamp, including necessary connection complete all as specified and directed.
Supply & fixing in repairs CT coil 100/5 Amps including necessary connection complete all as specified and directed.
Supply & fixing in repairs danger notice board / plate of size 20 cm x 15 cm, made out of 1.6 mm thickness mild sheet, vitreous enamelled white letters, figure and conventional skull and bones in Red colour and fixed with nuts and bolts for 1100 volts current complete all as specified and directed.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Permises around pole, around panel board along boundaries fencing, removing runnish material from work site and depositing where directed not exc. 100 meter from the starting point complete all as directed. Note : The item shall be operated maximum 2 (Two) times in the entire period of the Contract period and measurement will be taken every time independently for payment.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- (i) Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate. (ii) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Shri Amarnath Sah
M/S SARKAR BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .