Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 LAccepted-AOC | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹44.4 L+₹1.8 L (4.21%)Rejected-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹46.0 L+₹3.4 L (7.92%)Rejected-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹46.8 L+₹4.2 L (9.90%)Rejected-AOC 239 PHASE 2 MODEL TOWN BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L4 | Rejected-AOC AOC rejected. | |
| 5 | L5₹47.5 L+₹4.9 L (11.5%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-AOC AOC rejected. |
Tender Value
Refer Docs
EMD Value
₹99,200
Closing Date
23 Aug 2021, 6:00 pmClosed
GE DEHRADUN
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Addn/ Altn To Thimayya Auditoruim at RIMC, Provn Of 02 X Soakage Pit And Sewage Line For Bldg No P-6 Of 2/9 GR at Birpur, Special Repair to Bathroom of Bldg No P-2 AGs Branch and Bldg No T-27 ORs Bathroom of HQ Uttarakhand Sub Area under GE Dehradun
2021_MES_462762_1
8322/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE DEHRADUN
Class D cat a (i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹99,200
Yes
5 Oct 2021
26 Jul 2021
25 Aug 2021
26 Jul 2021
23 Aug 2021
9 Aug 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n. exc. 15 cm thickness(below or above ground level) complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed.
M&L for brick work (Except bricks) with sub class 'B' bricks, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:6) complete all as specified and directed (using old size bricks).
M&L for brick work with old size sub class 'B' bricks, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:4) complete all as specified and directed (using old size bricks).
M&L for 75mm thick cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor for laying floor finish complete all as specified and directed.
Taking down cement or cement lime plaster on walls of any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L for 15 mm thick cement plaster, I st coat 10 mm thick in cement morter 1:6 & II nd coat 5 mm thick in cement morter 1:4 with including water proofing compound, surface finished even and smooth without using extra cement. (Note:- Water proofing compound measured & paid seperately)
M&L for rendering 15mm thick in cement mortar 1:4 on walls (fair / unfair finished faces of brick/concrete), finished even and smooth without using extra cement complete all as specified. (Water proofing compound where ever ordered shall be added and the same will be measured and paid separately)
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06sqm but not exceeding 0.11 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick in CM 1:6 complete all as specified and directed .
M&L for glazed ceramic coloured tiles of size 350 x 250 x 6 to 7mm/ 450mm x 350 mm x 6-7 mm thick as on vertical surfaces such as skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface over & including rendering 10 mm thick in cement mortar 1:4 finished roung to fix tiles complete all as specified and directed.
Supply only integral water proofing compound complete all as specified & directed.
Taking down Chowkats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each complete all as specified and directed.
S&F solid PVC door frame of size 50mmx 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as shown in SSR Part – II 2010 and as directed by GE/Engineer-in-Charge. Make : “SYNTEX/RAJSHREE Plastic wood Forex ”, ECHON.
S&F 150 mm long,aluminium,anodised, barrel tower bolts of extruded section ISI marked complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised 150 mm size complete all as specified and directed.
M&L mild steel butt hinges, medium weight 100 mm size (including welding to steel chowkhats) ISI marked.
M&L for two coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified.
M&L for complete removal of existing treatment of wall and applying wall putty 2 to 3mm on walls to make the surface smooth and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal complete all as specified and as directed by Engr-in-Charge.
Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal complete all as specified and as directed by Engr-in-Charge.
Cutting of brick massonry wall for concealed water tubing and making good, cutting not exc 10 cm girth all as specified and directed.
M&L galvanized steel water tubing 15 mm bore medium grade with all fittings such as bends, tees, nipples, elbows, reducers, etc, fixed to walls and ceilings or laid in floors all as specified and directed.
M&L galvanized steel water tubing 20 mm bore medium grade with all fittings such as bends, tees, nipples, elbows, reducers, etc, fixed to walls and ceilings or laid in floors all as specified and directed.
Supply and fixed in repair 550 x 400 mm white vitreous china wash hand basin including brackets, cutting for and pinning in ends of brackets, 32 mm brass, chromium plated Waste fittings, with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed , PVC washout pipe, 15mm cast copper alloy fancy type chromium plated pillar tap with long screwed shanks and fly nuts or screwed for iron pipe complete all as specified.
S&F pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F full stall type white vitreous china urinal, (Excluding 'flushing cistern/flush pipe) complete all as specified and directed
S&F 32 mm dia waste fittings, brass chromium plated suitable for sink, WHB, etc with long screwed shanks and flynuts, flange embedded in cement complete all as specified and directed.
S&F 32 mm bore PTMT waste pipe suitable for wash hand basin/ sink etc not less than 610mm in length complete all as specified and directed.
S&F 450 mm long PVC connection with 15mm size PTMT nuts, of complete all as specified and directed.
S&F 15mm dia cast copper alloy chromium plated stop valve, screwed down high pressure with cluch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S&F in repair self closing galvanised cast iron or malleable cast iron taps for urinal, screwed for iron pipe and fixed
S&F in repair 150 mm square PTMT Grating with or without hole complete all as specified and directed.
S&F in repairs 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified.
S&F 75mm dia UPVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring,joints laid/fixed in wall/trenches complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring,joints laid/fixed in wall/trenches complete all as specified and directed.
S & F in repair PVC (SWR) bend,'T'socket reducer etc 75 mm bore complete.
S & F in repair PVC (SWR) bend,'T'socket reducer etc 110 mm bore complete.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
S&F mild steel framed work as in grills, grating etc. with end of bars shouldered and/or riveted, or forged into spikes: frame guard bars: barred iron doors: ladders: frame balusters: walk ways: railing: frame work of water tanks and similar works confirming to Fe- 410 or F-310-0 complete all as specified and directed .
S&F 1.60 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone agg as insub base for laying floor finishes complete all as specified and as directed.
M&L factory made prepolished rubber moulded vibromatic Chequred cement concrete tiles 30cmx30cmx22-25mm thick, set jointed and pointed in neat cement slurry with grey cement and colour pigment to matc over and including 15mm thick screed bedding layer in CM (1:6) complete all as specified.
M&L 10mm thick rendering in CM (1:3) on concrete surfaces finished even and smooth as in ceiling complete all as specified and as directed.
M&L 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggreate), as in plinth protection, finishing the surface even & fair without using extra cement the plinth protection shall be laid in alternate bays n exe 2 Sqm, 10mm joints shall be provided, joints shall be filled with bitumen mastic, bitumen mastic comprise of 1 Part of Hot bitumen 85/25 grade and 3 parts of sand all by weight complete all as specified & directed.
S&F 0.36 mm nominal dia stainless steel wire cloth with average aperture 1.40 mm and fixed with stainless steel wire staples complete all as directed by Engineer- in -Charge.
M&L for complete removal of paint from old decorated wooden surface by paint removers or burning off by blow lamp and cleaning with scraper and applying two coat of synthetic enamel paint on wooden surface over a coat of pink primer exc 10 cm width or girth incl preparetion of surfaces complete all as specified.
M&L for complete removal of existing treatment of ceiling and applying three coats of white wash on ceiling including preparation of surface complete all as specified and directed.
M&L for complete removal of existing treatment of walls and applying two coat of cement base paint on external wall surfaces complete all as specified in SSR Part I and directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade over a coate of white wash on walls all as specified & directed by Engineer-in-Charge.
S&F in repair 125 mm dia CP brass shower rose with or without swivel joints any size including fixing to steel pipe complete all as specified and directed.
S&F 15 mm dia with short body fancy type brass chromium plated bib taps, wall flange, and round headed knob screwed down to GI pipes or for brass ferule or to GI socket complete all as specified and directed.
S & F 500 Ltrs capacity Rotational moulded, polythene water storage tanks ( cylindrical shape with vertical top closed) hoisted and fixed in position all as specified in SSR part I including Ball valves 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic bal screwed for iron pipe and fixed. (minimum weight 15mm-142gms/20mm-210gms/25mm-455gms/40mm-690gms), including dismantling of existing broken PVC 500 ltrs water tank complete all as specified and directed.
S&F structural steel work as in roof trusses (framed), trussed, purlins crane gantries, rails & fastenings & heavy brackets framimg (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc. Structural steel conforming to Fe-410W, Grade-E 250, Quality 'A' .
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings complete all as specified and directed.
M&L Pre-painted galvanlume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strangth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for taking down existing roof treatment of any thickness or description including cleaning all upto roof slab incluing removing spoil from site & providing water proofing treatment described as under:- (a) Applying 15mm thick renedering in CM 1:4 over neat cement slurry @ 3.00 Kg/Sqm over cleaned roof surface with using of approved water proofing compoung. (b) Cleaning the plastered surface and applying (Resin & Hardner) smart care Epoxy Primer 2k of Make Asian paints or equivalent product of Thermax/ Berger ) on the cleaned surface for bonding of PU magnum with the existing concrete surface. (c) Supplying, providing and applying waterproofing treatment to Terrace area with Asian Paints Smart care PU magnum, single component highly elastomeric seamless cold applied modified PU coating or equivalent product of Thermax/ Berger) including all necessary surface preparation, coving using smart care multipurpose polymer, water pond test, etc. complete as per manufacture's specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1mm. The coating shall have dual combination of 250% elongation . Execution to be done with authorised applicator of the manufacturer and company back gurantee to be given by the contractor. Work will be executed in smart assurance system complete all as specified & directed by Engr-in-Charge.
Excavation over areas n.exc 1.50m deep and getting out in hard/ dense soil complete all as specified and directed.
Excavation over areas exc 1.50m deep but n.exc 3 m and getting out in hard/ dense soil complete all as specified and directed.
Excavation over areas exc 3m deep but n.exc 4.5 m and getting out in hard/ dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/ dense of soil for foundation, etc. or for shafts, wells, cesspits, manholes, pierholes, cable etc n.exc 10 Sqm on plan and getting out complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete as in sub base floor complete all as specified and directed.
M&L for brick work with sub class 'B' bricks in one brick thick honey comb walling, built in cement mortar 1:4 complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 (Nominal mix, using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves complete all as specified and directed.
M&L for loose filling with brick bats of size 80 to 150mm in soakage wells complete all as specified and directed by Engr-in-Charge.
M&L for use and waste form work to soffits of suspended slab such as roof slabs, floor slabs, landing and similar works, not exceeding 200mm thick for rough finished surfaces of concrete complete all as specified and directed.
S&F 150mm internal dia salt glazed stoneware drain pipe Gde 'A', laid in trenches and jointed in cement & sand mortar (1:1) complete all as specified and directed.
M&L for concrete in PCC (1:3:6) type C-2 ( using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed including demolition of SGSW pipe.
Returning, filling in soil including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed
M&L for 65 mm thick vibromatic reinforced precast cement concrete 1:1:2 (using 20mm graded stone aggregate) with 2mm thick mild steel CR sheet around painted with 2 coats of bituminous paint , as in man hole cover slabs finish fair even and smooth without using extra cement ( Top surface will be chequred finish) including necessary form work, 100 mm long handle of 12mm dia round bar counter sunk by 25mm welded to reinforcement complete all as specified and directed by Engr-in-charge (Note : CA No and date will be engraved on covers. Reinforcement shall be measured and paid saperately. Curing will carried out with ponding method)
S&F cast iron works grade FG 150, Unmachined in brackets, gully traps, gratings, railings, frames, manhole covers, fire and soot doors, dampers, part of ranges, balusters, Grating jali and similar articles.
M&L for dewatering and desludging of septic tank/sokage well of any size and depth mechanically (solid contents if not removed by mechanically should be removed by manually after taking permission from Engr-in-Charge) and removing the sludge out side of MOD complete all as directed at site. After complete cleaning of septic tank the manhole cover shall be re-fixed in same position with CM 1:4 and bleaching powder spread on top surface of septic tank @ 1 Kg per septic tank complete all as specified and directed at site.
Cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete al as specified and directed.
Cutting into existing road for the sewage/ drain pipe 150 mm bore and making good surface with PCC and road patchment material etc to match existing surface complete all as specified and directed.
S&F mild steel TMT bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia as specified .
M&L for Cleaning of existing sewage pipe lines 150/200mm internal dia at any depth through manholes by removing the manhole covers, by means of hydraulic jet pressure machine or manually as required at site, getting out sludge and liquid materials from connecting manholes and sewar line, flushing with water after cleaning, reinstating the manhole cover to the original postion and removing the solids and sludge out of MD land complete all as specified and directed. (Note: Cost of removal of sludge/liquid material from sewage lines and manholes in same line is included in rate of this item. A particular sewage line which is undertaken once for cleaning and paid for shall be kept functional for entire contract period and no extra payment shall be made for repitetive cleaning if required )
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified
S&F suspended gypsum board false ceiling made out of perforated, gyp board acoustical tiles of size 595 x 595 x 12mm thick including necessary frame work of gyp steel GI frame work constating intermediate channel of 15x45x0.9mm thick fixed at 1200mm centre to centre suspended with MS flat 25x3mm suspenders fixed to GI angle cleat fixed to structural members as directed. The perimeter channel of size 20x27x30x0.5mm thick shall be fixed at junction of wall and ceiling with scrump and rawal plugs at 600mm centre to centre at a height of 11 metre including two coats of acrylic emulsion over a coat of primer and preparation of surfaces complete all as specified. (Note : Joint of face board shall be finished with specifically formulated jointing compound and wide fibre tape to provide seamless finish). Make :- Saint Gobain or equivalent as approved by GE.
S&F 12 mm thick Acoustic wall panel ( size 1200x3200 mm) fixed with and over 50 mm GI Channel, 10 mm foam, 50 mm thick Rockwool of density 48 Kg/Cum and tissue paper, including two coats of acrylic emulsion over a coat of primer complete all as specified and directed by Engr-in-Charge. (Note : Joint of face board shall be finished with specifically formulated jointing compound and wide fibre tape to provide seamless finish). ( Make : Saint Gobain or equivalent
M&L for preparation of old wooden surface of any description, not otherwise described, over 10cm width or girth and applying two coat of french polish complete all as specified
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
M&L for point wiring with 1.5 Sqmm. (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings/ conduit on wall as required and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Engr-in-charge of following. (Note: Colour code shall be maintained as per IE rule).
One light point point controlled by one-one way switch.
One Fan point controlled by one-one way switch.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board.
All as per item 86 No above but with 4 Sq.mm. (nominal area) cable for one 3 Pin 15 amp socket on independent board complete all as specified.
S&F switch piano flush type single pole, 5 Amps, one way all as per specified & directed.
S&F switch piano flush type single pole, 15/16 Amps, one way all as per specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet 2-in1,3 pin 5 and 15 Amp flush type 250V AC complete all as specified & directed.
S&F ceiling rose surface bakelite 3 terminals of size 65x25mm. complete .
S&F LED tube light fitting 1x20 watt 230V, LED smart slimline stylish, energy saving luminaire, with diffuser one no LED tube 20 watt suitable for 4 fit complete all as specified and directed.
S&F energy saving Bulk head luminaire with opal diffuser with and including retrofit LED lamp 10 watts complete all as specified and directed by Engr-in-charge.
S&F Exhaust fan PVC AC single Phase 230 V / 240V 50 Hz of size 300 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old exhaust fan complete all as specified and directed.
S&F in repair sheet metal enclosures 240 volt 8 way with suitable rated bus bar for Single door IP-43DB's complete all as specified and directed .
S&F in repair MCB single pole 240 volt 10 KA 5 to 40 Amp, conforming to relevant IS complete all as specified & directed.
S&F in repair MCB SPN 240 Volt 10 KA 40 Amp conforming to IS complete all as specified
M&L in repair submain wiring with 3 runs(N+P+E) of 4 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed PVC conduit pipe of medium duty not less than 15 mm dia including necessary PVC conduit specials and connecting with suitable size thimble complete all as specified and directed. Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
Materials and labour, earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 m below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 20 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch all as shown in electrical plate No 3 of SSR Part-I 2009 including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia), with 40x40x6mm MS angle iron frame including necessary earth work and testing on completion, complete all as specified and as directed.
Supplying, laying, jointing and testing in replacement LT under armoured electric power cable 16 sqmm 2 core XLPE insulated, Screned PVC bedded galavanised steel strip or wire armoured conforming to IS 7098 (Part-I) 1985 ISI marked with aluminium multi stranded heavy duty 1100V laid in trenches / under floor, roads path or fixed on walls / on poles in heavy duty etc. as specified and directed of following size including lugs / thimbles / Glands including connecting testing & commissioning all bare conductor duly insulated 1.1 kv grade heat shrinkable sleeve at both ends complete all as directed by E-in-Charge.
S&F/ laying in repair 50 mm dia GI Pipe , (Medium grade) on wall/with pole/under PCC/under Road/ Under Pavments for cable protection all as specified and directed
Arun Construction Co.
R K BUILDERS
SARASWATI CONSTRUCTION CO
M/s Anil Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .