GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
REPAIR TO DG SETS, VOLTAGE STABILIZER AND REPAIR/ REPLACEMENT TO LT OVERHEAD LINES INCL CONNECTING WORK AT VARIOUS LOCATION OF RAJOURI UNDER AGE E/M OF GE 862 EWS
2023_MES_628289_1
GER-75/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS Rajouri
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹98,900
Yes
3 Feb 2024
14 Nov 2023
16 Dec 2023
14 Nov 2023
14 Dec 2023
28 Nov 2023
Amount
Repairing & servicing of 500 KVA DG set of any make by the authorised technician/ service engineer of OEM or their authorised service dealer, inspection and checking the machanical and electrical healthyness of the diesal engine and alternator, cylinder head assembly, piston system, piping system, cylinder liners, radiator function and cleaning thoroughly with cleaning agents and drain out engine oil including cleaning all sludge/deposits in the oil sump and removed off the site as per schedule, minor adjustment of control parameters, greasing, tracing out the defects, dismantling if necessary for replacement of defective spares and reassembing, testing and commissioning including taking out the old unserviceable one to keep the DG set healthy and serviceable required at 250 running hours or six months which ever is earlier as specified and directed by Engineer-in-Charge at site. (Notes :- (a) Spares parts, engine oil will be measured and paid saparately under relevant items. (b) In case, any abnormality found in between normal routine inspections, the service personnels must attend the service call urgently within 24 hrs.(c)Apart from these routine servicings, major repair/replacement if any as decided by Engineer-in-Charge will be measured and paid separately available within the scope of this schedule.(d)A Log Book indicating the details of all types of repairs and maintenance carried out time to time has to be recorded by the contractor's rep/supervisor and endorsed by JE(E/M) and AGE(E/M) . The contractor's rep/supervisor will monitor the serviceability of all the DG Sets and give report to JE (E/M) and AGE(E/M). This register is required to be produced at the time of claiming payment. (e) Replaced spare part shall be as per make of DG sets duly recommended by OEM.
All as per Srl Item No. 1.00 here-in-before but DG set of capacity 320 KVA.
All as per Srl Item No. 1.00 here-in-before but DG set of capacity 200 KVA.
All as per Srl Item No. 1.00 here-in-before but DG set of capacity 160 KVA.
All as per Srl Item No. 1.00 here-in-before but DG set of capacity 125 KVA.
All as per Srl Item No. 1.00 here-in-before but DG set of capacity 100 KVA.
All as per Srl Item No. 1.00 here-in-before but DG set of capacity 40 KVA to 63 KVA.
All as per Srl Item No. 1.00 here-in-before but DG set of capacity 15 KVA to 30 KVA.
Supply and fixing diesel filter element with all accessories suitable for D.G. Set 15 KVA to 30 KVA complete all as specified and directed.
All as per Srl Item No. 9.00 here-in-before but DG set of capacity 40 KVA to 63 KVA.
All as per Srl Item No. 9.00 here-in-before but DG set of capacity 100 KVA to 125 KVA .
All as per Srl Item No. 9.00 here-in-before but DG set of capacity 160 KVA to 200 KVA
All as per Srl Item No. 9.00 here-in-before but DG set of capacity 320 KVA.
All as per Srl Item No. 9.00 here-in-before but DG set of capacity 500 KVA.
Supply and fixing oil filter with all accessories for D.G. Set 500 KVA complete all as specified and directed.
All as per Srl Item No. 15.00 here-in-before but DG set of capacity 320 KVA.
All as per Srl Item No. 15.00 here-in-before but DG set of capacity 160 KVA to 200 KVA.
All as per Srl Item No. 15.00 here-in-before but DG set of capacity 100 KVA to 125 KVA.
All as per Srl Item No. 15.00 here-in-before but DG set of capacity 40 KVA to 63 KVA.
All as per Srl Item No. 15.00 here-in-before but DG set of capacity 15 KVA to 30 KVA.
S&F for air filter with all accessories air filter element complete with outer and inner suitable for D.G. Set 500 KVA capacity complete all as specified and directed.
All as per Srl Item No. 21.00 here-in-before but DG set of capacity 320 KVA.
All as per Srl Item No. 21.00 here-in-before but DG set of capacity 100 KVA to 125 KVA.
All as per Srl Item No. 21.00 here-in-before but DG set of capacity 40 KVA to 63 KVA.
All as per Srl Item No. 21.00 here-in-before but DG set of capacity 15 KVA to 30 KVA.
S&F for fan belt suitable for D.G. Set of capacity 500 KVA, complete all as specified and directed.
S&F for fan belt suitable for D.G. Set of capacity 320 KVA, complete all as specified and directed.
S&F for fan belt suitable for D.G. Set of capacity 100 KVA to 125 KVA, complete all as specified and directed.
S&F for fan belt suitable for D.G. Set of capacity 40 KVA to 63 KVA, complete all as specified and directed.
S&F for fan belt suitable for D.G. Set of capacity 15 KVA to 30 KVA, complete all as specified and directed.
S&F in repair for of rubber hose pipe set with clamps suitable for D.G. Set 500KVA capacity, complete all as specified and directed.
All as per Srl Item No. 31.00 here-in-before but DG set of capacity 320 KVA.
All as per Srl Item No. 31.00 here-in-before but DG set of capacity 100 KVA to 125 KVA.
All as per Srl Item No. 31.00 here-in-before but DG set of capacity 40 KVA to 63 KVA.
All as per Srl Item No. 31.00 here-in-before but DG set of capacity 15 KVA to 30 KVA.
Supply & filling for Engine Oil valvoline premuim blue, 20W 40, complete all as specified and directed.
Supply and filling Coolant for DG set, complete all as specified and directed
S&F in repair for water temperature gauge including sensor and cable complete all as specified and directed.
Dismantling the radiator of 40 KVA to 63 KVA DG Sets from engine, transportation to the workshop, repairing of top and bottom tank including necessary welding / brazing & making the radiator leak proof, cleaning the complete radiator internally with chemical agent (K Clean) and outside with Kerosene oil and high pressure water jet, and assembling the radiator including replacement of all old rusted mild steel nuts, bolts washers & gasket sets and hose pipe asembly including transportation from wksp to original work site & fixing to the engine and testing, complete all as specified and directed. (Coolant for radiator will be measurd and paid separately)
All as per Srl Item No. 39.00 here-in-before but DG set of capacity 100 KVA to 125 KVA.
All as per Srl Item No. 39.00 here-in-before but DG set of capacity 320 KVA to 500 KVA.
S&F in repair for water pump of suitable capacity for D.G. Set 40 KVA to 63 KVA capacity, complete all as specified and directed.
All as per Srl Item No. 42.00 here-in-before but DG set of capacity 100 KVA to 250 KVA.
S&F in repair for fuel pipe steel braded with benzo bolts, washers etc, length 30 cm long, complete all as specified and directed.
S&F in repair for fuel pipe steel braded with benzo bolts, washers etc, length 45 cm long, complete all as specified and directed.
S&F in repair for fuel pipe steel braded with benzo bolts, washers etc, length 60 cm long, complete all as specified and directed.
S&F in repair for fuel level indicator transparent PVC pipe of suitable dia for the fuel tanks complete all as specified and directed.
S&F in repair of fuel injection pump from the authorised dealer complete with all connected items as per existing for DG set 15 KVA to 30 KVA, complete all as specified and directed.
All as per Srl Item No. 48.00 here-in-before but for DG set 40 KVA to 63 KVA.
All as per Srl Item No. 48.00 here-in-before but for DG set 100 KVA to 125 KVA.
All as per Srl Item No. 48.00 here-in-before but for DG set 320 KVA to 500 KVA.
S&F in repair for gaskets, springs including tappet setting etc, complete all as specified and directed. Capacity of DG set 15 KVA to 30 KVA.
All as per Srl Item No. 52.00 here-in-before but for DG set 40 KVA to 63 KVA.
All as per Srl Item No. 52.00 here-in-before but for DG set 100 KVA to 125 KVA.
All as per Srl Item No. 52.00 here-in-before but for DG set 320 KVA to 500 KVA.
S&F in replacement for turbo charger of suitable capacity complete of DG set 40 KVA to 63 KVA capacity, complete all as specified and directed.
S&F in replacement for turbo charger of suitable capacity complete of DG set 100 KVA to 250 KVA capacity, complete all as specified and directed.
S&F in repair for battery 12 volts 180 AH red coloured specially designed for diesel Gen Set, complete all as specified and directed .
S&F in repair for battery 12 volts 120 AH red coloured specially designed for diesel Gen Set, complete all as specified and directed .
S&F in repair for battery 12 volts 92 AH red coloured specially designed for diesel Gen Set, complete all as specified and directed .
S&F in replacement of battery leads set, PVC insulated multisranded, copper conductor 70sqmm, each 1.25 mtr long, duly fitted with brass clamps, copper lugs for DG sets of any capacity, complete all as specified and directed.
Supply & filling of distlled water for batteries, complete all as specified and directed
Repair of self starter of capacity 12 volts including all connected items, complete all as specified and directed
All as per Srl Item No. 63.00 here-in-before but self starter of capacity 24 volts.
Preparation of old steel painted surfaces by cleaning/ rubbing/ scraping of old paint from the DG set of capacity 200-320 KVA as per existing and making surfaces ready for paint outdoor and indoor and spray painting with gun one coat of synthetic enamel paint of approved colour, including writing SM/MES No, capacity and other details with white paint all as required at site or as directed.
Preparation of old steel painted surfaces by cleaning/ rubbing/ scraping of old paint from the DG set of capacity 63-100 KVA as per existing and making surfaces ready for paint outdoor and indoor and spray painting with gun one coat of synthetic enamel paint of approved colour, including writing SM/MES No, capacity and other details with white paint all as required at site or as directed.
S&F in repair for aluminium tubular lugs of cable size 10 Sqmm to 16 Sqmm, complete all as specified and directed by Engr-in-Charge.
S&F in repair for aluminium tubular lugs of cable size 25 Sqmm to 50 Sqmm, complete all as specified and directed by Engr-in-Charge.
S&F in repair for aluminium tubular lugs of cable size 70 Sqmm to 120 Sqmm, complete all as specified and directed by Engr-in-Charge.
S&F in repair for aluminium tubular lugs of cable size 150 Sqmm to 300 Sqmm, complete all as specified and directed by Engr-in-Charge.
S&F in repair for copper lugs of cable size 10 Sqmm to 16 Sqmm, complete all as specified and directed by Engr-in-Charge.
S&F in repair for copper lugs of cable size 25 Sqmm to 50 Sqmm, complete all as specified and directed by Engr-in-Charge.
S&F in repair for copper lugs of cable size 70 Sqmm to 120 Sqmm, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of rectifier from the authorised dealer complete with all connected items as per existing make for DG set 15 KVA to 30 KVA, complete all as specified and directed.
All as per Srl Item No. 74.00 here-in-before but for DG set 40 KVA to 63 KVA.
All as per Srl Item No. 74.00 here-in-before but for DG set 100 KVA to 125 KVA.
All as per Srl Item No. 74.00 here-in-before but for DG set 320 KVA to 500 KVA.
S&F in replacement for automatic voltage regulator from the authorised dealer with all connected items as per existing makr for DG set 15 to 30 KVA complete as in repair as per existing all as specified and directed.
All as per Srl Item No. 78.00 here-in-before but for DG set 40 KVA to 63 KVA.
All as per Srl Item No. 78.00 here-in-before but for DG set 100 KVA to 125 KVA.
All as per Srl Item No. 78.00 here-in-before but for DG set 320 KVA to 500 KVA.
S&F in replacement of lubrication oil temp sensor/ fuel level sensor from the authorised dealer complete with all connected items as per existing make for DG set capacity 15 KVA to 30 KVA, complete all as specified and directed
All as per Srl Item No. 82.00 here-in-before but for DG set 40 KVA to 63 KVA.
All as per Srl Item No. 82.00 here-in-before but for DG set 100 KVA to 125 KVA.
All as per Srl Item No. 82.00 here-in-before but for DG set 320 KVA to 500 KVA.
S&F in replacement of coolent temperture sensor from the authorised dealer complete with all connected items as per existing make for DG set capacity 15 KVA to 30 KVA, complete all as specified and directed
All as per Srl Item No. 86.00 here-in-before but for DG set 40 KVA to 63 KVA.
All as per Srl Item No. 86.00 here-in-before but for DG set 100 KVA to 125 KVA.
All as per Srl Item No. 86.00 here-in-before but for DG set 320 KVA to 500 KVA.
All as per Srl Item No. 90.00 here-in-before but suitable for capacity 24 Volts.
S&F in replacement for phase indicator LED lamp with holder in different colours i.e. Red, yellow & green , complete all as specified and directed.
S&F in repair for Onload change over switch of sheet steel enclosure confirming SS Enclosure, front operated 4Pole 415 V, 50 Hz of Capacity 160 Amps, complete all as specified and directed.
S&F in repair for Onload change over switch of sheet steel enclosure confirming SS Enclosure, front operated 4Pole 415 V, 50 Hz of Capacity 250 Amps, complete all as specified and directed.
S&F in repair for Onload change over switch of sheet steel enclosure confirming SS Enclosure, front operated 4Pole 415 V, 50 Hz of Capacity 630 Amps, complete all as specified and directed.
S&F in replacement for battery charging alternator 12/24 Volt suitable for 1500 RPM DG set as per exiting complete all as specified and directed.
M&L in replacement for PCB assembly control PCC 1301, Item Code No. 0327-1513-01 suitable for Cummins Engine DG sets complete all as specified and directed.
M&L in replacement for control assembly, Item Code No. 0300-6014 suitable for Cummins Engine DG sets complete all as specified and directed.
S&F in repair for broken hinges for DG set door as per existing size and make of DG set, complete all as specified and directed by the Engr-in-Charge.
Repair to broken door DG set capacity from 200 KVA to 500 KVA by welding including complete denting painting with nut bolt, complete all as specifie directed by Engr-in-Charge.
All as per Srl Item No. 102.00 here-in-before but for DG set 40 KVA to 160 KVA.
VOLTAGE STABILIZERS Taking out unserviceable control wiring complete from voltage stabilizer capacity from 5KVA and upto 25 KVA, 3 phase 415 volts of any make for unbalanced load, providing wiring loom complete, made out of suitable size PVC insulated copper conductor cable including cables lugs, connectors, channels etc complete all as specified and directed. Note:- Cost of copper wire used shall be deemed to be included in quoted rate measured and paid separetaly.
All as per Srl Item No 104.00 here-in-before but capacity of stabilizers above 25 KVA and up to 50 KVA.
All as per Srl Item No 104.00 here-in-before but capacity of stabilizers above 50 KVA and up to 100 KVA.
All as per Srl Item No 104.00 here-in-before but capacity of stabilizers above 100 KVA and up to 300 KVA.
S&F in replacement of analog voltmeter of size 72 x 72 mm range 30 to 300 volts, complete all as specified and directed.
S&F in replacement of printed control card circuit suitable for voltage stabilizers of capacity upto 100 KVA as per existing make, complete all as specified and directed.
S&F in repair for holder for printed control card circuit suitable for voltage stabilizer including connections by soldering complete all as specified and directed.
S&F in repair for servo motor single phase AC 230 volts suitable to work with voltage stabilizer upto 50 KVA capacity as per eexisting make with torque up to 5 Kg/CM complete all as specified and directed.
All as per srl item No 111 here-in-before but stabilizer above 100 KVA capacity above with torque above 5Kg/CM upto 12 Kg/CM.
S&F in replacement of dimmer stat suitable for voltage stabilizer of any capacity upto 5 to 25 KVA of any make to match with existing system. Complete all as specified and directed.
All as per Srl Item No. 113 here-in-before but for capacity of motor 50 KVA
All as per Srl Item No. 113 here-in-before but for capacity of motor 100 KVA
All as per Srl Item No. 113 here-in-before but for capacity of motor 300 KVA
Supply and filling in replacement of new transformer oil of dielectric strength not less than 40 KV to various voltage stabilizers, complete all as specified and directed.
M&L for rewinding of burnt voltage stabilizer and transformer, primary and secondary winding with super enamelled copper winding wire of size and gauge as per existing including insulation, varnishing, drying and testing for stabilizer of capacity of 5 KVA to 300 KVA as per manufacturer's design including removing old winding complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth foy laying of cables, pipe line, protection pipes and foundation, etc and getting out in soft loose soil, complete all as specified and directed.
Excavating in trenches, n. exc 1.5m wide and exc more than 1.5m in depth for foundation for erection of poles, etc and getting out in any type soil, complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting poin, complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness i.e 18cm of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 300 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands including taking down old cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 185 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands including taking down old cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands including taking down old cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands including taking down old cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands including taking down old cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands including taking down old cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands including taking down old cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
S&F for Aluminium conductor steel reinforced (ACSR) of any description including stretching on overhead line on LT poles to required sag and binding with aluminium binding wire to insulators including jumpering the OH line jointing after dismantling of old unserviceable over head ACSR conductor of any type and size inlcuding all clamps, jumpering etc and kept in safe custody for reuse of serviceable ACSR etc complete all as specified and directed.
S&F for Pin type, porcelain viterous white, brown or green insulator including one glavanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height, 65 mm dia for 1100 volts grade after dismantling of old unserviceable pin type insulator complete all as specified and directed.
M&L for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches for cable protection including taking down old GI pipe complete all as specified and directed.
M&L for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches for cable protection including taking down old GI pipe complete all as specified and directed.
M&L for 40mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches for cable protection including taking down old GI pipe complete all as specified and directed.
S&F for MCCB 63 Amps four pole adjustable thermal and magnetic setting type,16 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
S&F for MCCB 100 Amps four pole adjustable thermal and magnetic setting type,16 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
S&F for MCCB 160 Amps four pole adjustable thermal and magnetic setting type, 25 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
S&F for MCCB 200 Amps four pole adjustable thermal and magnetic setting type, 35 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
S&F for MCCB 250 Amps four pole adjustable thermal and magnetic setting type,35 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
S&F for MCCB 400 Amps four pole adjustable thermal and magnetic setting type,35 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
S&F for MCCB 63 Amps four pole adjustable thermal and magnetic setting type,10 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
M&L for steel tubular swaged poles errected to truly vertical position with 6mm thick mild steel base plate of size 300mm x300mm, welded to Pole, B-118 finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II, type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide at 300mm spacing alternately and marking pole number. with black paint at suitable height including taking down old unserviceable broken steel pole of 9 mtr long complete all as specified and directed. (Note :- Necessary excavation of earth work, removing, returning filling in, PCC foundations of poles, coping etc shall be measured and paid separately)
M&L for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete of poles and stay/installation paths complete all as specified and directed.
M&L for plain cement concrete type C-1 , 1:3:6 (using 20mm graded stone aggregate) as in poles foundation including necessary form work complete all as specified and directed.
M&L for complete removal of existing paint by scraping from the steel tubular swaged pole of 9 mtr height without removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamel paint upt 1.50mtr height having alternative white and yellow strips of 30cm height each, including one coat of aluminium paint to the remaining part of pole and numbering of poles (i.e above 1.50 mtr height) and its corss arms bracing, support and all steel members complete etc all as specified and directed.
Cutting/trimming of tree branches upto 100mm thick under OH LT electric line including cleaning upto 1.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers small bushes etc of under OH line upto 60 mtr each sapn and depositing the cut branches upto 50mtr from the pole including taking shut down in writing with all safety measure as per electric rules complete all as directed by Engineer-in-Charge. (Note :- Materials/T&P like Axes, rope, gloves,safety harness etc. and the like will be provided by the contractor without any extra cost )
M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earthwork, Earth strip and protection pipe upto board is included in the rate quoted)
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2009 including testing on completion after dismantling of old unserviceable earthing with material etc. complete all as specified and directed. (Note:-Earthwork, Earth strip and protection pipe upto board is included in the rate quoted)
S&F in repair for cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material ) heat shrink type) and accessories suitable for XLPE armoured aluminium conductor 1100 volts grade of size 35 to 70 Sqmm 3.5 core laid cable and testing after jointing, complete all as specified directed.
S&F in repair for cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material )heat shrink type) and accessories suitable for XLPE armoured aluminium conductor 1100 volts grade of size 95 to 150 Sqmm Sqmm 4/3.5 core laid cable and testing after jointing, complete all as specified directed.
S&F in repair for cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material )heat shrink type) and accessories suitable for XLPE armoured aluminium conductor 1100 volts grade of size 185 to 400Sqmm Sqmm 3.5 core laid cable and testing after jointing, complete all as specified directed.
Supply , install, testing and commissioning of factory made bus bar chamber panel of size 600mmx 900mmx350mm ( CPRI approved) out door type 3.15 mm with 4 strips 200 Amps bus bar aluminium, with MCCB of 40 Amp, FP, 16 KA adjustable type duly connected to aluminium strip at incoming side with suitable space for 2 incoming cable and outgoing of 2 cable. Bus bar fixed on insulators in zig-zag position, clearance in each strip and clearnace at both side should not be less than 125mm with sufficient working space, height of bus bar chamber not less than 1 mtr, mounted MS angle 50x50x6mm, shutter in two parts, cable opening form bottom side with indicators R,Y,B, hinges through out the length of shutter with half turn locking arrangement, including grounting in PCC, including taking down old bus bar chamber complete all as directed by Engr-in-charge.
Repairing of LT panels of any size by welding, grinding etc & removing of rust and applying one coat of red oxide primer & spary painting with the existing colour to match with existing surface, inserting rubber packing on doors, glands for cables complete all as specified and directed by Engr-in-charge. Note: Angle iron of any size, sheets etc used for repairing will be included in the quoted rate.
M/S PARSHOTAM KUMAR GUPTA
M/s Kay Aar Enterprises
M/S SOHUM ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .