Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC NIL | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.7 L+₹32,233 (1.51%)Rejected-AOC AIR FORCE ROAD GORAIMARI HALESHWAR TEZPUR SONITPUR ASSAM 784104 | SONITPUR | ASSAM | 784104 | L2 | Rejected-AOC Become L2 | |
| 3 | L3₹22.1 L+₹64,420 (3.01%)Rejected-AOC MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L3 | Rejected-AOC Become L3 | |
| 4 | L4₹23.1 L+₹1.7 L (7.97%)Rejected-AOC | L4 | Rejected-AOC Become L4 | |
| 5 | L5₹25.2 L+₹3.8 L (17.8%)Rejected-AOC | L5 | Rejected-AOC Become L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Jun 2020, 6:00 pmClosed
GE SOUTH TEZPUR
GE SOUTH TEZPUR MISSION CHARALI
REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION AND OTHER ALLIED WORKS AT ZONE 1 (HQ 4 CORPS, STN HQ, SIGNAL CENTRE, PRU, PRS) UNDER GE (S) TEZPUR
2020_MES_351155_1
8497
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH TEZPUR
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE SOUTH TEZPUR
₹60,000
Yes
25 Aug 2020
9 Jun 2020
2 Jul 2020
9 Jun 2020
30 Jun 2020
23 Jun 2020
Amount
Taking down carefully copper /alluminium point wiring (light ,fan, sockets light / power etc.) complete with fitting and fixtures such as all type of switches, ceiling rose, regulators, sockets ,light fitting, calling bell ,cover plates, boxes, PVC /metallic holder , casing, caping, conduit pipe etc.all to be made credit to contractor and making good to disturbed surface of wall as per exisitng all as specified and directed.
M&L for point wiring for one light point / Fan point controlled by one switch using 1.5 Sqmm PVC insulated unsheathed single core muiltistranded copper conductor cable 1100 volts grade confirming to IS- 694 drawn through in PVC casing caping in suitable size and PVC box for housing to modular switches and using 1.5 Sqmm PVC insulated unsheathed single core muitistaindard copper conductor cable 1100 volts cable as earth wire to connecting as common earth dolly for light point controlled by one switch complete all as specified and directed.
M&L for point wiring for one light point controlled by one switch using 1.5 Sqmm PVC insulated unsheathed single core muiltistranded copper conductor cable 1100 volts grade confirming to IS- 694 drawn through in PVC casing caping in suitable size and PVC box for housing to modular switches and using 1.5 Sqmm PVC insulated unsheathed single core muitistaindard copper conductor cable 1100 volts cable as earth wire to connecting as common earth dolly forsocket point 5 Amps on the independent board complete all as specified and directed.
M&L for point wiring for one light point controlled by one switch using 1.5 Sqmm PVC insulated unsheathed single core muiltistranded copper conductor cable 1100 volts grade confirming to IS- 694 drawn through in PVC casing caping in suitable size and PVC box for housing to modular switches and using 1.5 Sqmm PVC insulated unsheathed single core muitistaindard copper conductor cable 1100 volts cable as earth wire to connecting as common earth dolly for sockets point on the same board with other swithches complete all as specified and directed.
M&L for point wiring for 2.5 Sqmm copper cable for 15 Amps sockets on independent board and using 1.5 Sqmm PVC insulated unsheathed single core muilti strandard copper conductor cable 1100 volts cable as earth wire to connecting as common earth dolly confirming to IS- 694 drawn through in PVC Conduit pipe medium grade heavy duty in suitable size and PVC box for housing to modular switches complete all as specified and directed.
M&L for point wiring for one call bell point controlled by one switch using 1.5 Sqmm PVC insulated unsheathed single core muiltistranded copper conductor cable 1100 volts grade confirming to IS- 694 drawn through in PVC casing caping in suitable size and PVC box for housing to modular switches and using 1.5 Sqmm PVC insulated unsheathed single core muitistaindard copper conductor cable 1100 volts cable as earth wire to connecting as common earth dolly for sockets point on the same board with other swithches complete all as specified and directed.
M&L for point wiring for one light point controlled by two way switch using 1.5 Sqmm PVC insulated unsheathed single core muiltistranded copper conductor cable 1100 volts grade confirming to IS- 694 drawn through in PVC casing caping in suitable size and PVC box for housing to modular switches and using 1.5 Sqmm PVC insulated unsheathed single core muitistaindard copper conductor cable 1100 volts cable as earth wire to connecting as common earth dolly for light point controlled by one switch complete all as specified and directed.
S & F in repair electronic fan regulator,100W ,230V ,50Hz stepped socket type for ceiling fan complete all as specified.
S&F in repair switch piano type, 5 Amp. SP, one way all as directed/ specified.
S&F in repair switch piano type, 15 Amp. SP, one way all as directed/ specified.
S&F in repair switch socket outlet, 2 in one 5 pin, 5 Amp, piano type all as directed.
S&F in repair switch socket combination 2 in 1, 6 pin 5 and 15 Amp flush type universal all as directed/ specified.
S&F in repair switch bell push, flush type, 5 Amp all as directed/ specified.
S&F in repair bell, AC, 230 V, SP, ding dong type all as directed & specified.
S&F in repair of Ceiling rose 3 phase, PVC/ Polycarbonate body all as directed/ specified.
S&F in repair switch two way switch flush type, 5 Amp all as directed/ specified.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 105 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and directed.
M&L for point wiring using 2.5 Sqmm copper conductor single core FRLS 1100 volts grade cable for 15 Amps sockets on independent board and using 1.5 Sqmm PVC insulated unsheathed single core muilti strandard copper conductor FRLS cable 1100 volts grade as earth wire to connecting as common earth dolly confirming to IS- 694 drawn through in PVC casing caping in suitable size and PVC box for housing to modular switches complete all as specified and directed.
M&L for in repair of lamp holder PVC/ polycarbonate type with cord grip cap suitable for pendent/ back plate as required complete. Note : Type of holder given by deppt.
M&L in repair of only for top plug 16 Amps 240 volts 3 pin PVC/ polycarbonate.
M&L in repair of for top plug 6 Amps 240 volts 3 pin PVC/ polycarbonate.
M&L in repair of rigid non metallic PVC casing & caping or conduit pipe medium grade heavy, 25 mm dia of bore but inclusive of all tees ,bens ,elbow, reducers, bell mouth tube ends and fixing accessories such as couplers ,lock nuts, saddles, pipe hooks etc for telephone and TV cable cable as laid seprately .
M&L for point wiring using 4 Sqmm copper conductor single core FRLS 1100 volts grade cable for power point 20 Apms sockets on independent board and using 2.5 Sqmm PVC insulated unsheathed single core muilti strandard copper conductor FRLS cable 1100 volts grade as earth wire to connecting as common earth dolly confirming to IS- 694 drawn through in PVC casing caping in suitable size and PVC box for housing to modular switches complete all as specified and directed.
S&F in repair wall mounting industirial socket including top plug with suitable straight plug, 220 to 280 volts, 2 poles SP&N enclosure, 20 Amps, Tamper Proof IP 67 to used as single phase industrial load complete all as specified and directed.
S&F in repair wall mounting industirial socket including top plug with suitable straight plug, 180 to 250 volts, 3 polesTP&N enclosure, 30 Amps, Tamper Proof IP 67 to used as single phase industrial load complete all as specified and directed.
M&L for point wiring for one light / fan point controlled by one switch using 1.5 Sqmm PVC insulated unsheathed single core muiltistranded copper conductor cable 1100 volts grade confirming to IS- 694 drawn through in conceled as site required PVC conduit pipe medium grade heavy duty in suitable size and mettalic box for housing to modular switches and using 1.5 Sqmm PVC insulated unsheathed single core muitistaindard copper conductor cable 1100 volts cable as earth wire to connecting as common earth dolly complete for light point controlled by one switch as directed . Note :- Unit rate shall be included chasing/ cutting /plastering/ painting and matching with existing wall surface painting etc to surface of wall (if required) complete.
M&L for point wiring for one light point controlled by one switch using 1.5 Sqmm PVC insulated unsheathed single core muiltistranded copper conductor FRLS cable 1100 volts grade confirming to IS- 694 drawn through in conceled as site required PVC conduit pipe medium grade heavy duty in suitable size and mettalic box for housing to modular switches and using 1.5 Sqmm PVC insulated unsheathed single core muitistaindard copper conductor cable 1100 volts cable as earth wire to connecting as common earth dolly complete for socket point 5 Amps on the independent board as directed.
M&L for point wiring for one light point controlled by one switch using 1.5 Sqmm PVC insulated unsheathed single core muiltistranded copper conductor FRLS cable 1100 volts grade confirming to IS- 694 drawn through in conceled as site required PVC conduit pipe medium grade heavy duty in suitable size and mettalic box for housing to modular switches and using 1.5 Sqmm PVC insulated unsheathed single core muitistaindard copper conductor cable 1100 volts cable as earth wire to connecting as common earth dolly complete for sockets point on the same board with other swithches as directed .
M&L for point wiring using 2.5 Sqmm copper cable for 15 Amps sockets PVC insulated unsheathed single core muiltistranded copper conductor cable 1100 volts grade confirming to IS- 694 drawn through in conceled as site required PVC conduit pipe medium grade heavy duty in suitable size and mettalic box for housing to modular switches and on independent board and using 1.5 Sqmm PVC insulated unsheathed single core muilti strandard copper conductor cable 1100 volts cable as earth wire connecting to as common earth dolly as directed . Note :- Unit rate shall be included chasing/ cutting /plastering/ painting etc to surface of wall (if required) complete.
all as per above but for one bell point controlled by one, one 5 amp switch
S&F in repair of modular metal flush box of module 1/3/2 flush ISI marked all as specified and directed.
S&F in repair of modular metal flush box of module 4 flush ISI marked all as specified and directed.
S&F in repair of modular metal flush box of module 6 /8flush ISI marked all as specified and directed.
S&F in repair of modular white cover plate with frame of module 1 flush ISI marked all as specified and directed.
S&F in repair of modular white cover plate with frame of module 2/3flush ISI marked all as specified and directed.
S&F in repair of modular white cover plate with frame of module 4 flush ISI marked all as specified and directed.
S&F in repair of modular white cover plate with frame of module 6 ISI marked all as specified and directed.
S&F in repair of modular white cover plate with frame 8 module ISI marked all as specified and directed.
S&F in repair of modular blank plate module 1 all as specified and directed.
S&F in repair of modular switch flush type, 6 Amp. SP, one way ,1 module all as directed specified.
S&F in repair of modular socket outlet, 3 pin, 6 Amp, flush type 2 module all as directed/ specified.
S&F in repair of modular switch, 16 Amp flush type 1 module all as directed/ specified.
S&F in repair of modular socket outlet, 3 pin, 6/16 Amp flush type 2 module all as directed/ specified.
S&F in repair of modular bell push, flush type, 5 Amp,1 module all as directed/ specified.
S&F in repair of modular Fan Regulator step type 2 module ,120W all as directed/ specified.
Taking down old unsv submain wiring of any size complete all as specified and directed
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 2.5 Sq mm drawn through PVC conduit and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length.
M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC conduit and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length.
Supply and fixing single phase Electronic tamper proof energy meters with LCD display of 10-60A capacity 230V AC 50Hz ISI marked and celing the meter(Top & Bottom covers) with suitable lead wire and connecting up incomming and outgoing cable connetions to meter including taking down old unsv meter and taking to MES Store of meter including testing and commisioning complete.
S& F ceiling fan of sweep not less than 1200mm with hanger in repair of existed old vintage unseviceable ceiling fan as specified and directed.
S&F in repair exhaust fan size of sweep not less than 300 mm copper wounded winding energy saving single phase, 230 volts, 50 HZs with louver, set of sweep and all connecting accessories including making all electric connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed.
S&F in repair exhaust fan size of sweep not less than 230 mm copper wounded winding energy saving single phase, 230 volts, 50 HZs with louver, set of sweep and all connecting accessories including making all electric connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed.
Supply and fix in repair , wall mounting fan size of sweep not less than 450 mm heavy duty energy saving single phase, 230 volts, 50 HZs complete all connecting accessories including making all electric connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed.
Taking down old unsv LED lights of any wattage , any type including all its accessories complete all as specified and directed.
Supply and Fixing in repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution not less than 9W 2 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting complete all as directed.
Supply and Fixing in repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution not less than 20W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as per complete all as directed.
S & F in repair not less than 12 Watt LED fitting surface mounted , 6500k, colour temp >= 5700K with die cast body with premier diffuser ensuring glare free light including taking down old unserviceable type downlighter all as specified and directed.
S & F in repair surface accessory module for not less than 12 Watt LED fitting with all its accessories including taking down old unserviceable module all as specified and directed.
Taking down fans any type /model/ size etc complete with all connecting accessories incl dismenteling the fan blade and other accessories to be kept in safe custody and depositing in AGE yard for re-using the same at site all as specified and directed.
M&L for rewinding of ceiling fan,1200mm any make and any type of model, after taking burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG Varnishing, baking in oven and reassembling with new bearings both complete all as specified and directed
M&L for rewinding of Exhaust fan 300mm any make and any type of model, after taking burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG Varnishing, baking in oven and reassembling with new bearings complete all as specified and directed
M&L for rewinding of Exhaust fan 400mm any make and any type of model, after taking burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG Varnishing, baking in oven and reassembling with new bearings complete all as specified and directed
M&L for painting of fan (ceiling fan / exhaust fan/wall mounted fan ) any sweep with applying one coat of synthetic enamel paint (Ceiling Fan -White Paint and Exhaust fan - Gray Paint ) by spray machine including preparation of old painted surfaces with filling of cavity by filler with and including writting of MES No. of fan in capital letters with black synthetic enamel paint of height not less than 20mm on fan body in approved pattern complete all as specified and directed.
Supply and Fix louver shutter (with Mosquito net made out Aluminium wire cloth 0.36 mm nominal dia ) made out GI sheet (Thickness of louver shutter Body 1mm ,shutter Fins 0.5 mm fixed with 3 mm GI wire ) for Exhaust fan 300/400 mm sweep including proper fixing with screw in wall at existing Hole including taking down old unsv louver shutter complete all as specified and directed.
S & F Gun metal bush for ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv bush.
S & F Canopy (top and bottom) for ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv Canopy.
S & F Rubber packing with hanging bolt for ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv Rubber.
S & F Ball bearing (Bearing No- 6201/6202) of ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv bearing complete all as specified and directed.
S & F Capacitor( 2.5-4) MFD for ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv capacitor.
S & F Down rod 15mm bore medium grade GI pipe including cut in required length and drilled as per existing size including taking down old unsv down rod complete all as specified and directed.
S & F Fan blade for Ceiling fan of 1200mm sweep of white colour including taking down old unsv fan blade complete all as specified and drected.
Taking down old Unsv DB of any type & any capacity complete all as specified and directed
S & F Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed.
S & F Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed.
S & F Power line vertical type TPN DB double door 4 way, IP 43 suitable for MCCB 100 amps CRCA sheet metal enclouser with detachable gland plates for flush / surface mounting with bus bar neutral link and Earth Bar in concealed and all disturbed surfaces of wall shall be made good to match the existing wall finishes complete all as specified and directed.
S&F in repair of metering Panel, powder coated factory made for mounting Electric meter at stair case for 4 electric meters, box should be cubical indoor type modular design of not less than 900 mm x 900mm x200mm , with 2mm thick CRCA sheet steel with IP 52 tested, fabricated by welded frame construction with CRCA frame section, compartmentalised (Modular) desing. The cable entry shall be from the bottom and top of the panel provided with suitable dia brass gland plates for provisioning specific bending radius for cable. The panel shall have opening arrangements front side mounted on hinges as and fitting fixure in wall as specified and directed .
Taking down old Unsv MCB/MCCB/RCBOs of any type & any capacity complete all as specified and directed
S & F MCB SP 6 to 32 Amp,C series , 230 Volts complete all as specified and directed.
S & F MCB DP 6 to 32 Amps, C series, 230 Volts complete all as specified and directed.
S & F MCB DP 40-63 Amps, C series, 230 Volts complete all as specified and directed.
S & F MCB TPN 10 KA "C" series 415 Volt complete all as specified and directed.
S & F MCCB 4 Pole 415V Fixed type 25-100A with breaking capicity 16 KA complete all as specified and directed.
Supply and fixing in repair water heater (Geyser) storage type, single phase, energy saving 5 star rated 230 volts grade 25 Ltrs storage capacity complete with fixing accessories.
Supply and fixing in repair water heater (Geyser) storage type, single phase, energy saving 5 star rated 230 volts grade 10 Ltrs storage capacity complete with fixing accessories.
Supply and fix Heating element of 1500/2000 watts suitable for 25 ltrs capacity water heater including taking down old unsv element complete all as specified and directed.
S & F Thermostat of range 0-80 degree Celsius suitable for 25 Ltrs water heater including taking down old unsv thermostat complete all as specified and directed.
M/S Kangkans
D G Corporation
Shree Krishna Traders
M/S SR BUILDERS
United Traders
M/S Manjit Singh
M/S GOSWAMI ENGINEERING
M/S Himalayan Trading Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .