Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-AOC 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | ₹1.3 L Quoted ₹1.4 L | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹1.7 LRejected-Finance D NO CC XX 1487 B1 CC 18 1786 B1 NEAR VVLP SCHOOL KONAM PALLURUTHY P O KOCHI 682006 | ERNAKULAM | KERALA | 682006 | ₹1.7 L | L2 | Rejected-Finance Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | AR Traders L1 | COCHIN CHEMICALS L2 |
|---|---|---|---|---|---|
| 1.00 | Supply and fix factory built hermetically sealed compressor unit suitable for 1.5 Ton, single phase, 230 V, 50Hz capacity split / window type AC, testing the leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerant gas including taking out old unserviceable compressor with connected old material from the split type ACs /window ACs complete all as specified and as directed. | 1 | Each Job | 9,500 ₹9,500 | 13,000 ₹13,000 |
| 2.00 | `-Ditto- all as per item No 01 above but 2.0 TR | 1 | Each Job | 10,000 ₹10,000 | 14,000 ₹14,000 |
| 3.00 | Material and labour for Leak testing of Window / Split type ACs, Water cooler, Refrigerator, Deep freezer etc. including filling of nitrogen gas for pressure testing, finding leaks, Vacuuming the system, necessary brazing work, charging with refrigerant gas ( R-22 / R 304 a /R 407a /R 134 ) of required quantity, testing for proper functioning complete all as specified and as directed. | 10 | Each Job | 1,500 ₹15,000 | 865 ₹8,650 |
| 4.00 | Material and labour for onsite servicing 1.5 / 2.0 Ton capacity split / window type AC of any description by cleaning air filter, cooling coil / condenser coil and outer cabinet with pressurised water and detergent solution, applying new insulation to torn/damaged insulation complete all as specified and as directed. | 16 | Each Job | 500 ₹8,000 | 720 ₹11,520 |
| 5.00 | Supply and fix in repairs of condenser fan motor with capacitor and mounting materials, single phase, 230 Volts, 50 Hz suitable for 1.5/2.0 Ton capacity split type AC including taking out old unserviceable blower motor complete all as specified and as directed. | 2 | Each | 300 ₹600 | 2,400 ₹4,800 |
| 6.00 | Supply and fix in repairs of thermostat cut off switch suitable for 1.5 / 2.0 Ton capacity split / window type AC complete all as specified and as directed. | 2 | Each | 100 ₹200 | 800 ₹1,600 |
| 7.00 | Supply and fix in repairs of overload protective relay suitable for 1.5/2.0 Ton capacity window type AC complete all as specified and as directed. | 5 | Each | 100 ₹500 | 480 ₹2,400 |
| 8.00 | Supply and fix in repairs of starting relay suitable for 1.5 /2.0 Ton capacity window type AC complete all as specified and as directed. | 4 | Each | 100 ₹400 | 420 ₹1,680 |
| 9.00 | Supply and fix in repairs of copper, aluminium mixed alloy condenser suitable for up to 1.5 Ton capacity split / window type AC complete all as specified and as directed. | 1 | Each | 1,200 ₹1,200 | 4,500 ₹4,500 |
| 10.00 | Supply and fix in repairs of copper, aluminium mixed alloy condenser suitable for 2.0 Ton capacity split type AC complete all as specified and as directed. | 3 | Each | 1,300 ₹3,900 | 5,200 ₹15,600 |
Updated dates
Tender Value
₹2 L
EMD Value
₹4,000
Closing Date
17 Nov 2025, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
REPAIR/MAINT OF COOLING APPLIANCES LIKE SPLIT/ WINDOW ACs, WATER COOLERS, DEEP FREEZERS ETC AT SMA RAMESWARAM UNDER GE FORT KOCHI
2025_MES_735011_1
8290/E8_GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
270 days
FORT KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹300
GE FORT KOCHI
₹4,000
Yes
23 Dec 2025
14 Oct 2025
24 Nov 2025
14 Oct 2025
17 Nov 2025
28 Oct 2025
Amount
Supply and fix factory built hermetically sealed compressor unit suitable for 1.5 Ton, single phase, 230 V, 50Hz capacity split / window type AC, testing the leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerant gas including taking out old unserviceable compressor with connected old material from the split type ACs /window ACs complete all as specified and as directed.
`-Ditto- all as per item No 01 above but 2.0 TR
Material and labour for Leak testing of Window / Split type ACs, Water cooler, Refrigerator, Deep freezer etc. including filling of nitrogen gas for pressure testing, finding leaks, Vacuuming the system, necessary brazing work, charging with refrigerant gas ( R-22 / R 304 a /R 407a /R 134 ) of required quantity, testing for proper functioning complete all as specified and as directed.
Material and labour for onsite servicing 1.5 / 2.0 Ton capacity split / window type AC of any description by cleaning air filter, cooling coil / condenser coil and outer cabinet with pressurised water and detergent solution, applying new insulation to torn/damaged insulation complete all as specified and as directed.
Supply and fix in repairs of condenser fan motor with capacitor and mounting materials, single phase, 230 Volts, 50 Hz suitable for 1.5/2.0 Ton capacity split type AC including taking out old unserviceable blower motor complete all as specified and as directed.
Supply and fix in repairs of thermostat cut off switch suitable for 1.5 / 2.0 Ton capacity split / window type AC complete all as specified and as directed.
Supply and fix in repairs of overload protective relay suitable for 1.5/2.0 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in repairs of starting relay suitable for 1.5 /2.0 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in repairs of copper, aluminium mixed alloy condenser suitable for up to 1.5 Ton capacity split / window type AC complete all as specified and as directed.
Supply and fix in repairs of copper, aluminium mixed alloy condenser suitable for 2.0 Ton capacity split type AC complete all as specified and as directed.
Supply and fix in repairs of 30 / 36 mfd running capacitor suitable for 1.5 / 2.0 Ton capacity split / window type AC complete all as specified and as directed.
Supply and fix in repairs of PVC fan blade suitable for 1.5/2.0Ton capacity split / window type AC complete all as specified and as directed.
Supply and fix in repairs of Prime Control Remote Board and temperature digital display sensor suitable for split type/ Window AC of any capacity, make or model all as per site requirement complete all as specified and as directed.
Supply and fix in repairs of liquid strainer suitable for 1.5 / 2.0 Ton capacity split type AC complete all as specified and as directed.
Supply and fix in repairs of capillary tube for 1.5 / 2.0 Ton capacity split type AC complete all as specified and as directed.
Supply and fix in repairs of factory built hermetically sealed compressor unit suitable for 40 / 60 / 80 Ltrs capacity water cooler, testing the leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134/R-22 Refrigerant gas including taking out old unserviceable compressor from the water cooler complete all as specified and as directed.
`-Ditto- all as per item No 16 here in above but suitable for 100 / 150 Ltrs capacity complete all as specified and as directed.
Supply and fix in repairs of starting relay assembly suitable for 40 / 60 / 80 Ltrs capacity water cooler complete all as specified and as directed.
Supply and fix in repairs of running capacitor suitable for 40 / 60 / 80 Ltrs capacity water cooler complete all as specified complete all as specified and as directed.
Supply and fix in repairs of overload relay suitable for 40 / 60 / 80 Ltrs capacity water cooler complete all as specified and as directed.
Supply and fix in repairs of thermostatic switch suitable for 40 / 60 / 80 Ltrs capacity water cooler complete all as specified and as directed..
Supply and fix in repairs of 15mm dia brass chromium plated push cock / lifting cock suitable for 40 / 60 / 80 Ltrs capacity water cooler complete all as specified and as directed.
Supply and fix in repair 15mm dia PVC high pressure release valve complete all as specified and as directed.
Supply and fix in repairs of condenser fan motor, single phase, 50 Hz, 230 Volts suitable for 40 / 60 / 80 Ltrs capacity water cooler complete all as specified and as directed.
Supply and fix in repairs of 15mm dia, 450mm long, PVC connection with brass check nuts, complete all as specified and as directed.
Supply and fix in repairs of liquid strainer suitable for any capacity of water cooler complete all as specified and as directed.
Supply and fix in repairs of capillary tube suitable for any capacity water cooler complete all as specified and as directed.
Supply and fix in repairs for plug top suitable for industrial socket/normal 16 Amp socket complete all as specified and as directed. Make : Legrand / Standard / Havells/ Anchor
Supply and fix repairs to voltage stabilizer 5 KVA by rewinding the main stabilizing unit and replacing PCB, sensing unit, power relay, connector piece and testing on completion all as specified and as directed.
Supply and fix in repairs of copper pipe OD of any size including connecting to split type AC and applying insulation complete all as specified and as directed.
Supply and fix in repairs of PVC drain pipe one metre long 32mm dia heavy duty with two Nos of galvanized adjustable clamps complete all as specified and as directed.
Supply and filling of Refrigerant Gas-R-22 in ACs/ Water coolers/ Refrigerators of any model and capacity including leakage testing complete all as specified and as directed.
Supply and filling of Refrigerant Gas R- 32 ,ACs/Water coolers/Refrigerators of any model and capacity including leakage testing complete all specified and as directed.
Supply and fix in repairs of Fan motor suitable for outdoor unit of 3 phase tower AC of any capacity make or model all as specified. and as directed.
Writing letters or figures for permanent marking of MES No with anti-corrosive enamel paint not exceeding 03 cm in height as numbers obtained from Engineer-in-charge in window AC/ Split ACs inner and outer unit and water cooler /refrigerator etc. with thick approved colour paint complete all specified and as directed.
Supply and fixing in repairs of indoor unit and outdoor unit kit of 2.0 TR split type ACs of any make by dismantling the old indoor unit and outdoor unit connecting up with existing outdoor unit and indoor unit including complete indoor unit items like blower fan, PCB / Remote controls etc. and excluding out door unit components like compressor, condenser fan motor and condenser unit, copper pipe complete set and necessary brazing as per site requirement etc. complete all as specified and as directed.
Material and Labour for disconnection the power supply of split ACs and dismantling, taking down split ACs, any make / mode/ type of capacity 1.5/ 2.0TR from existing location including indoor units/ outdoor units along with its copper pipes, connecting cables, clamps/ stands, water drain pipes etc. including making good the surfaces to match with existing finishes in all respects and re-fixing at new location as directed with all accessories such as clamps, pipes, stand for outdoor unit including top up of refrigerant gas if required and making satisfactory working of AC unit in all respect complete all as specified and as directed.
COCHIN CHEMICALS (BID ID -3470058)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
8290Tenderdocu.pdf
Tender Documents • 0.82 MB
BOQ_823041.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid