Loading…
Loading…
Tender Value
₹32.3 L
EMD Value
₹33,000
Closing Date
7 May 2026, 12:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
EXECUTIVE ENGINEER, AHMEDABD ELECTRICAL DN NO 1
Providing and Erecting of Active component for Data Networking system at New RTO office, subhashbridge, Ahmedabad.
301078
03/01 of 2026-2027
Open
Electrical
Ahmedabad
10 documents required · 10 mandatory
₹1,500
EXECUIVE ENGINEER, AHMEDABD ELECTRICAL DN NO 1,AHMEDABAD
₹33,000
5 May 2026
5 May 2026
5 May 2026
7 May 2026
5 May 2026
Providing and Erecting of Active component for Data Networking
system at New RTO office, subhashbridge, Ahmedabad.
Sr. No. Qnty. Item Description Figures Per Amount
NIL NIL NIL NIL NIL NIL NIL
Dy. Executive Engineer
Signature of Contractor M.S. Elect. Sub- Division
R & B Deptt., Ahmedabad.
Name of Providing and Erecting of Active component for Data Networking system at New RTO office,
Work: subhashbridge, Ahmedabad.
Qty Unit Rate in words Rate in figure Amount
SITC of O. F.Cable 06F Outdoor - Armoured Unitube SM - HDPE
Rupees Fifty And Paise
1 Sheath [Approved by Competent Authority i.e. not Below the rank of 500 Mtrs. 50.50
Executive Engineer ]
Rupees Six Thousand
SITC of LIU 12 PORT Rack Mount - Loaded (LC) SM [Approved by
2 19 Ea. Nine Hundred One And 6901.33
Competent Authority i.e. not Below the rank of Executive Engineer ]
Paise Thirty Three Only
Rupees Seven Hundred
SITC of PIGTAIL LC SM SIMPLEX LENGTH- 1m [Approved by
3 144 Ea. Seventy Nine And Paise 779.72
Competent Authority i.e. not Below the rank of Executive Engineer ]
Seventy Two Only
SITC of Face Plate - Single (Keystone Jack,square) [Approved by Rupees Ninety And
Competent Authority i.e. not Below the rank of Executive Engineer ] Paise Ninety Only
Rupees One Hundred
SITC of Jack Cat 6 Keystone UTP [Approved by Competent
5 60 Ea. Sixty One And Paise 161.60
Authority i.e. not Below the rank of Executive Engineer ]
Supply, Installation, testing and commissioning of 24 port Cat 6 19"
Modular Toolless Patch Panel (loaded) enable all possible
combinations of the various types of cable (UTP, FTP, SFTP)
mounted on the same panel by using various toolless connector
blocks/modules. Have a metal structure enabling them to be durably
fixed to the uprights of the 19" chassis and assuring automatic
grounding between toolless RJ-45 connectors, the panel, and the
19" uprights of the enciosure. Include rear cable support with plastic
Thousand Eight Hundred
6 cable guides to hold cable without need for cable ties. Include quick 19 Ea. 12819.83
Nineteen And Paise
mounting system to mount the panel into the 19" rails without use of
Eighty Three Only
cage-nuts. These may be used to secure the connections of wifi
access points, IP cameras, servers, or other critical devices. Front
Removal IO's option for maintenance and trouble shooting with
Different Colours Labels for Labelling & Identification of Individual
Ports. Tested and guaranteed under dual circuit and up to Minimum
2400 on-load connections / disconnections. Make-Commscope/
Panduit/ Legrand/D-link
SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U' Snag less Rupees One Hundred
7 [Approved by Competent Authority i.e. not Below the rank of 456 Ea. Fifty Six And Paise Fifty 156.55
Executive Engineer ] Five Only
SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U' Snag less Rupees Two Hundred
8 [Approved by Competent Authority i.e. not Below the rank of 220 Ea. And Paise Ninety Nine 200.99
Executive Engineer ] Only
SITC of 8 x 10/100/1000BASE-T PoE ports
2 x Gigabit SFP ports
Advanced L2 switching and security features
Rupees Eighteen
L2+ Static Routing
9 2 Ea. Thousand Four Hundred 18400.18
Optional “standard mode” or “surveillance mode” management user
And Paise Eighteen Only
65W PoE budget [Approved by
Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Maximum distance of up to 10 km
Single-mode fiber Rupees Four Thousand
10 1000BASE-LX (IEEE 802.3z standard) 48 Ea. Eight Hundred One And 4801.54
Duplex LC connector Paise Fifty Four Only
MSA, RoHS-compliant [Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Providing following type of Modular Type Accessories mounted with
PVC / metallic/Wooden box, single mounting base frame covered Rupees One Hundred
11 with textured / metallic/white front plate , modules erected with 20 Ea. Sixty And Paise Fifty 160.59
necessary connections as per site situation directed by Engineer In Nine Only
charge.(8) Computer RJ-45 socket (Cat.III)
Supply, Installation, testing and commissioning of 9U/600
Rack/Welded/WM/Off White, Glass Door/9U/WM/Gray,Server /IT Rack
mount power distribution unit, 1Ph, 230V, 16A, 50/60Hz, 2U standard with
6 X Indian Round Pin 5/15A, Inlet Plug type 16A Indian Round Pin, 16A MCB Rupees Fourteen
PDU Rating Cable 3.6KVA/Side feed-1.5MV Black, Horz. Organiser/1U/Loop, Thousand One Hundred
Cantilever Shelf/Type2/1U/OH White, Mounting Hardware-CR (Pack of 20). One And Paise Ninety
ITE/Server Rack Air Circulation module/90CFMMake- Subnet, Netrack,D- Two Only
link, Elixer. as per selection of authority /building committiee
Supply, Installation, Testing & Commissioning of 27U (600W X
600D)MM floor rack with PDU, Horizontal Cable manager, self,
mounting hardware and cooling fan with standard accessories. UL Rupees Thirty Four
Certified. Racks should be manufactured by ISO9001:2015, Thousand Eight Hundred
ISO14001:2004 & OHSAS 18001 : 2007, DIN41494 and Equivalent Twenty One And Paise
EIA/ISO/EN /CEA Certified company and should have proper EHS Seventy Seven Only
Policy.Make- Subnet, Netrack,D- link, Elixer.
Supply, installation, testing and commissioning of Network switch
24Port 100M / 1G / 10G gigabit managed POE/POE+ Switch, QOS
Support, IPV4/IPV6 Support, Advance Security Management, 480 Gbps Rupees One Lakh(s)
Twenty Thousand Three
14 Switching Fabric, 1 Gbps Non-blocking ports and Internet Group 17 Ea. 120365.74
Hundred Sixty Five And
Management Protocol: IGMP V2/V3, Mac, windows, Linux Compatible Paise Seventy Four Only
complete with standard acessories.make -Netgear, Cisco
Rupees Thirty Two Lakh(s) Thirty Thousand Eight Hundred Thirty Three And Paise Fifteen Only
I/We am/are willing to carry out the work at % above/below percent(Should
be written in figures and words) of the estimated rate mentioned above. Amount of my /our tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct……………..…% below Add …………….. /% Above
In words In words
The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for
which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement
Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design
the cost of difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned
in all the tender.
Dy. Executive Engineer
Signature of Contractor M.S. Elect. Sub- Division
R & B Deptt., Ahmedabad.
NATIONAL COMPETITIVE BIDDING
1. The Dy. Executive Engineer, M.S. Electrical Sub Division , Ahmedabad invites bids for the construction of works detailed in the table. The bidders may submit bids for
any or all of the following works.
Approximate value of #Class ofRegistration/ Category of contractor if
Package Name of work Bid Security document Period of completion
works (Rs.) required
Providing and Erecting of Active component
for Data Networking system at New RTO 3,230,833.15 33,000 1500 7 Days E1 class and above
office, subhashbridge, Ahmedabad.
2. Prospective / Interested bidder may download the Bid Documents from websitehttps://www.nprocure.com free of cost till the Time and Date as mentioned on online NIT at website
https://www.nprocure.com.
3. However, Bidder who is submitting the Bid Online will have to pay the Bid Document Fee / Tender Fee through Demand Draft only of any Schedule Bank payable at Ahmedabad and in favour of ‘Dy.
Executive Engineer, M.S. Electrical Sub Division , Ahmedabad’. Once the Bid is received Online, Bid Document / Tender Fee will not be refundable.
The Demand Draft for Bid Document / Tender fee and FDR / Bank Guarantee against Bid Security / EMD shall be submitted in electronic format through online (by scanning) while uploading the bid, this
submission shall mean that bid document / tender fee and Bid Security / EMD has been received. Accordingly, the offer of only those shall be opened whose Bid Document / Tender Fee and Bid Security / EMD
have been received electronically. However, for the purpose of realization of Demand Draft, and FDR / Bank Guarantee bidder shall send the same in original through R.P.A.D. so as to reach to #‘ ‘‘Dy.
Executive Engineer, M.S. Electrical Sub Division , Ahmedabad' within 7 Days from the last day of bid submission.
Penetrative action for not submitting Demand Draft / FDR / Bank Guarantee in original to ‘Dy. Executive Engineer, M.S. Electrical Sub Division , Ahmedabad / Tender Inviting Authority by bidder shall be
4. Bids received online, will be opened on the time, date and place as specified in the online NIT at website https://www.tender.nprocure.com in the presence of the bidders or their authorized representatives,
who wish to remain present.
If the office happens to be closed on the day of opening of the bids as specified, the bids will be opened on the next working day at the same time and venue.
5. A pre bid meeting will be held on --at --hrs. at the office of --to clarify the issues and to answer questions on any matter that may be raised at that stage as stated in clause
9.2 of ‘instructions to Bidders’ of the bidding documents.
6. #Bid Security (EMD) is equal to 1% of Estimated Amount put to bid / tender and should be rounded off to the next thousand rupees.(As per NIT)
7. Other Information is as under:
A. Agencies can prepare and edit their offers a number of times before the end of the tender submission date and time. After the tender submission date and time, the bidder cannot modify / edit / withdraw their
submitted offer in any case. No written or online request in this regard shall be granted.
B. Offers in physical form will not be accepted in any case.
C. Demand Draft purchased by the other then bidder and issued after the last date of submission of Bids, will not be considered or accepted.
D. The cost incurred by the contractor for this offer for clarification or attending discussion, conferences or site visits will not be reimbursed by the Employer or Engineer-in-Charge.
E. Conditional tender shall not be accepted.
F. Any changes, addition, alternation made in the prescribed form attached with tender are liable to be rejected.
7. Other Information is as under:
A. Agencies can prepare and edit their offers a number of times before the end of the tender submission date and time. After the tender submission date and time, the bidder cannot modify / edit / withdraw their
submitted offer in any case. No written or online request in this regard shall be granted.
B. Offers in physical form will not be accepted in any case.
C. Demand Draft purchased by the other then bidder and issued after the last date of submission of Bids, will not be considered or accepted.
D. The cost incurred by the contractor for this offer for clarification or attending discussion, conferences or site visits will not be reimbursed by the Employer or Engineer-in-Charge.
E. Conditional tender shall not be accepted.
F. Any changes, addition, alternation made in the prescribed form attached with tender are liable to be rejected.
G. Any change in format or conditional Bank Guarantee will not be accepted and the bidder will be considered non-responsive.
H. All the bidders are instructed to fill in information strictly in accordance with the format given in the checklist /qualification document / tender document.
I. It is mandatory for the bidders to supply each and every information as asked strictly in electronic format at appropriate places only.
J. Blank / insufficient information shall be treated as nil information and shall result in disqualification.
K. Even if the bidder has been qualified in a similar or larger size of project in the past, it shall not be deemed to be a ground / reason for not giving required information for this work / bid.
L. Information supplied for earlier projects shall not be considered while evaluation of this bid. The Government will not ask for any other information, unless it is found absolutely necessary by the competent
M. If found necessary, the contractor will be intimated for negotiation,
# For the works costing up to 7.5 crore (ROAD), 7.0 crore (BUILDING & BRIDGE) kindly refer to SSR-10-2015-17-C dated 03-02-2017
For the works costing under 7.5 crore for Road Works and 7.0 crore for Building and Bridge Works following documents shall be submitted in electronic format only through online by scanning and the (i) Bid
Document Fee / Tender Fee (ii) Bid Security / EMD should be sent in original to the Tender opening authority through RPAD, so as to reach the Executive Engineer within 7 days from last day of submission of
(i) Bid Document Fee / Tender Fee.
(ii) Bid Security / EMD or Valid EMD Exemption Certificate of Appropriate Class of Registration of Approved Contractors
(iii) Valid Electrical Contractor Registration Certificate of Appropriate Class E-1 Class and above.
(iv) Valid Contractor License issued by the licensing Board of Gujarat
(v) Registration Certificate of Special Category - Road / Bridge / Building and Category I / II / III, if required
(vi) GST Number, PAN Number
(vii) Work Experience, if necessary…
(viii)Undertaking by agency ensuring access/ availability of credit facilities up to 25 percent of the value of the contract as per SBD.
Dy. Executive Engineer
M.S. Elect. Sub- Division
Signature of Contractor R & B Deptt., Ahmedabad.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
GR AND GST LTR.pdf
Notice No.03.pdf
PQ CRITERIA Data networking RTO.pdf
SBD Document.pdf
SCHEDULE A AND B AND NCB.pdf
Sp.condition for RTO.pdf
Download all tender documents and submit your bid