Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹28.6 L+₹2.4 L (9.25%)Rejected-Finance 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹32.0 L+₹5.8 L (22.2%)Rejected-Finance 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹32.7 L+₹6.5 L (24.6%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
10 Apr 2024, 6:00 pmClosed
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
REPAIR AND MAINT OF WINDOW/SPLIT AND DUCATABLE TYPE ACs, WATER COOLER, DEEP FREEZER, REFRIGERATOR IN THE AREA OF GE (A) NO.1 JODHPUR.
2024_MES_646036_1
GE/JODH (A) NO 1- OF 2023-24 (9231/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY NO. 1
₹80,000
Yes
2 Oct 2024
12 Mar 2024
19 Apr 2024
12 Mar 2024
10 Apr 2024
27 Mar 2024
Amount
M&L for taking down, checking of window type air conditioner of any make/capacity (1.5/2 TR ) in any location and position at Army Area Jodhpur including necessary servicing .ie. electrical connection/wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality, cleaning cooling coil, replacement of micro filter of approved quality, testing for proper functioning of window type air conditioner in situ complete incl labour for gas charging/top up, complete all as specified and as directed. Note : .(i)- Quoted rate are deemed to be inclusive for maintain proper complete record of machine i.e., Make with cap and location , date of servicing, user signature after servicing, concerned JEs signature duly verified by the Engr-in-Charge. (ii) Quoted rate are deemed to be inclusive cost of both end bushes of approved quality, cleaning cooling coil, micro filter of approved quality, Cleaning & descaling of condensing unit and cooling coil with caustic soda mixed water and air blower & sludge etc. and Greasing/oiling of blower fan motorall as directed by Engr-in-Charge. (iii) Minor charging/ top up of gas if reqd and cost of gas will be paid seperately under respective item of sch A
All as per item No. 1.00 but suitable for Split type Acs of any Make/ Capacity (1.5/ 2.0 Ton), complete all as specified and as directed.
M&L for Servicing only of Split/Window type Acs of any Make/ Capacity (1.5/ 2.0 Ton) in any location & position at Army Area Jodhpur including cleaning of drain water pipes, making electrical connections / wiring, etc., complete all as specified and as directed by Enginner-in-charge. Note : .(i)- Quoted rate are deemed to be inclusive for maintain proper complete record of machine i.e., Make with cap and location , date of servicing, user signature after servicing, concerned JEs signature duly verified by the Engr-in-Charge. (ii)- This item qty shall not be overlapped with the qty's of item No. 1.00 & 2.00.
M&L in replacement of rotary type sealed reciprocating conventional compressure suitable for 1.5 ton capacity of window/ split type ACs, including pressuring system checking for leakage in system and flush out the system etc., disconnecting, taking down old existing u/s sealed unit., complete all as specified and as directed Note: Gas charging etc shall be measured and paid separately under relevant item of schedule 'A'.
All as per item No. 4.00 but suitable for 2.0 Ton capacity of window/ split type Acs, complete all as specified and as directed.
All as per item No. 4.00 but Reciprocating type sealed reciprocating conventional compressure, complete all as specified and as directed.
All as per item No. 6.00 but suitable for 2.0 Ton capacity of window/ split type Acs, complete all as specified and as directed.
M&L for pressurising complete system of split/window type at any existing location, single phase air conditioner, checking leakage and flushing out system, rectification of leakages if any and including gas charging using refrigerant as per existing oil charging complete in compressor of Window/Split type AC cap.1.5/2.0 Ton all as directed & with entire satisfaction of Engr-in-Charge, complete all as specified and as directed. Note : Quoted rate are deemed to be inclusive cost of Refrigerant, if required.
M&L for rewinding of blower motor (speed 900 RPM) of window/Split Air conditioner of cap. 1/5 HP any make with super enamelled copper conductor winding wire including replacement of worn out bushes, shaft and capacitor etc and testing, complete all as specified and as directed.
Supply and replacement of running capacitor clip type of cap. 50 MFD, 240 volts 50 cycles for window/ split type air conditioner 1.5/2.0 Ton Cap, complete all as specified and as directed
Supply and replacement of running capacitor clip type of cap. 06 MFD, 240 volts 50 cycles for window/ split type air conditioner 1.5/ 2.0 Ton Cap, complete all as specified and as directed
Supply and replacement of running capacitor clip type of cap. 12 MFD, 240 volts 50 cycles for window/ split/ duct type type air conditioner, complete all as specified and as directed
M&L for replacement of thermostatic switch for window type AC cap. 1.5/2.00 Ton Capacity, complete all as specified and as directed.
M&L for replacement of temp Sensor for Split/window type AC cap. 1.5/2.00 Ton Capacity, complete all as specified and as directed.
Supply and fixing in replacement of single phase contactor ( for 1.5 Ton cap. For split/ window type AC, complete all as specified and as directed.
M&L in replacement of cooling/condensor coil for Split type AC Cap. 1.5/2.0 TR (as per existing make) Etc, complete all as specified and as directed
Material and labour for replacement of cooling/condensor coil for window type AC Cap. 1.5/2.0 TR (as per existing make) Etc, complete all as specified and as directed
M&L for taking out and refixing split type ACs any cap/Make from one location to another location including pressurising the system ,testing and leakage rectification in system , making good disturbed surfaces and texisting, complete all as specified and as directed Note :- Rates are deemed to included for making holes for suction , discharge pipe and condensed water pipe (ii ) extra lenth of copper pipe duly insulated and gas if required shall be paid seperately .
Material and labour for replacement of 3 core 4 sqmm (Nominal area) multistranded copper conductor cable, 1100 volts grade ,FRLS,complete all as specified and as directed
Material and labour for replacement of cord less remote (as per existing make & model) with control panel suitable for split type AC Cap 1.5/2.0 Ton, complete all as specified and as directed.
Material and labour for replacement of Swing motor of split type AC cap 1.5/2.0 Ton with flapper complete all as directed by Engr-in-Charge.
Material and labour for replacement of PVC condensed water drain pipe nylon braided 15 mm dia for split type AC complete including providing saddle with clamping arrangement , complete all as specified and as directed.
Material and labour of Rubber insulation for suction/discharge copper tubes , complete all as specified and as directed.
Material and labour for replacement of copper discharge tube of size (1/4)"/(3/8)' duly nylon insulated, complete all as specified and as directed.
Material and labour for replacement of copper suction tube of size (1/2)"/ (5/8)" duly nylon insulated , complete all as specified and as directed.
Supply and fixing blower motor of indoor unit for 1.5/ 2.0 TON cap split type AC (Make Blue star/Voltas complete as per sample) as in replacement, complete all as specified and as directed.
Supply and fixing exhaust fan motor of outdoor unit for 1.5/ 2 TON cap split type AC (Make Blue star/Voltas complete as per sample) as in replacement, complete all as specified and as directed.
Supply and fixing of indoor unit for 1.5 TON cap split type AC complete as per sample) as in replacement, complete all as specified and as directed.
Supply and fixing of indoor unit for 2.0 TON cap split type AC , complete as per sample as in replacement, complete all as specified and as directed.
M&L for Repair of PCB for indoor unit of split type AC 1.5/2 Ton capacity of existing make and model as per sample, complete all as specified and as directed.
Supply and replace of PCB for indoor unit of split type ACs 1.5/2 Ton of existing make and model as per sample, complete all as specified and as directed.
Supply and replace of PCB for outdoor unit of split type AC (inverter type) 1.5/2 Ton of existing make and model as per sample, complete all as specified and as directed.
M&L checking of split type three phase air conditioner of any make / capacity 7.5/5.5/3.76/ 3.0 in location and position at any site in AA Jodhpur including necessary servicing ie: electrical connection /wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil ,replacement of micro filter of approved quality and testing for proper functioning of split type air conditioner, incl labour for gas charging/ top up, complete all as specified and as directed. Note : .(i)- Quoted rate are deemed to be inclusive for maintain proper complete record of machine i.e., Make with cap and location , date of servicing, user signature after servicing, concerned JEs signature duly verified by the Engr-in-Charge. (ii) Quoted rate are deemed to be inclusive cost of both end bushes of approved quality, cleaning cooling coil, micro filter of approved quality, Cleaning & descaling of condensing unit and cooling coil with caustic soda mixed water and air blower & sludge etc. and Greasing/oiling of blower fan motorall as directed by Engr-in-Charge. (iii) Minor charging/ top up of gas if reqd and cost of gas will be paid seperately under respective item of sch A
Material and labour for ,pressurising complete system of split type at any location, three phase air conditioner, checking leakage and flushing out system , rectification of leakages if any and including gas charging using refrigerant M- 404/444/R-22 oil charging complete in compressor /Split type AC cap.7.5/5.5/3.76/3.0 Ton all as directed & with entire satisfaction of Engr-in-Charge Note : Cost of Gas will be paid under separately under Schedule 'A'
M & L for disconnecting, existing U/S sealed unit and replacement with new three phase hermatic sealed rotary compressure cap -3.5/3.76 ton ( for split type ACs), complete all as specified and as directed. Note: Gas charging etc shall be measured and paid separately under relevant item of schedule 'A'.
Supply only refrigerant gas as per existing, ( Note : (i) The gas is to be supplied in cylinder duly sealed by manufacturer/ factory sealed with proper PVs and other documents, complete all as specified and as directed.
Supply and replacing blower motor of indoor unit for 3/3.5Ton cap split type AC (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement, complete all as specified and as directed.
Supply and replacing blower motor of indoor unit for 2 TON cap split type AC(Cassette ) (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement, complete all as specified and as directed.
Supply and replace PCB for indoor unit of three phase split type Acs any capacity, complete all as specified and as directed.
Supply and replace PCB for Out door unit of three phase split type Acs any capacity, complete all as specified and as directed.
Supply and replace contactor for outdoor unit of Single phase split type Acs any capacity / make as per existing /sample.
Supply and replacing fan motor of outdoor unit for 4/5 Ton cap Three phase split type AC (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement, complete all as specified and as directed.
Supply and replacing fan motor/Blower motor for out door for 3/3.5 TON cap three phase split type AC (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement, complete all as specified and as directed.
Material and labour for carefully dismentlling of automatic electronic voltage stablizer of cap 4KVA/5 KVA of any make and replacement of PCB and transformer complete unit reassembling and testing complete, complete all as specified and as directed.
Supply and replacing single pole and neutral enclosure with 2 pin earth plug ad socket complete with one MCB SP 25 Amps (Make -Legrand/Havells) as in replacement, complete all as specified and as directed.
material and labour for replacement of PVC/Fibre sheet 3m thick of superior quality of canopy of out door unit , complete all as specified and as directed.
M&L,checking of Refrigerators/Deepfreezer of any make / capacity in location and position at any site in AA Jodhpur including necessary servicing ie: electrical connection /wiring, cleaning , door gasket cleaning evaporator cleaning and testing for proper functioning of refrigerators/ deep freezer , complete all as specified and as directed.( The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no ,SM no. capacity, date of servicing , user signature after servicing , concerned JEs signature all as directed by engineer incharge )
Material and labour for replacement of unserviceable hermetically sealed compressor of Deep freezer 405 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete all as specified and as directed. NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company .(ii) The new unit will be purchased from authorised dealer only as per existing make and model.
Material and labour for replacement of unserviceable hermetically sealed compressor of Refrigerator / deep freezer 310/280 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete all as specified and as directed. NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company .(ii) The new unit will be purchased from authorised dealer only as per existing make and model.
All as per ser item No 49 above but for 165/170/180 /220 Ltr capacity refrigerator, complete all as specified and as directed.
Material and labour for replacement of relay suitable for 286/310/320 Litres cap. Refrigerator, complete all as specified and as directed.
All as per ser item No 51 but cap 165/220 Ltrs Refrigerator, complete all as specified and as directed.
Material and labour of replacement of thermostat automatic defrost with knob suitable for 165 to 310 liters cap refrigerator , complete all as specified and as directed.
Material and labour for replacement of door gasket of best quality complete suitable for 286/310 litres cap. Refrigerator as per manufacturer's instruction , complete all as specified and as directed.
All as per ser item No 54 above but for 165/220 Ltrs Cap., complete all as specified and as directed.
Material and labour bulb for pin/screw type, 230 Volts suitable up to310 Ltrs Cap. Refrigerator as in replacement, complete all as specified and as directed.
Material and labour for replacement of freezer door incl. necessary door springs, screws etc for 286/310 Ltrs Cap. Refrigerator complete all as specified and directed by Engr-in-Charge.
All as per ser item No 57 above but for 165/220 Ltrs cap. Refrigerator, complete all as specified and as directed.
Material and labour for replacement of door lock with keys-2 nos. for any capacity of refrigerator , complete all as specified and as directed.
Material and labour for replacement of PVC chiller tray and suitable for 286/310 Ltrs Cap. Refrigeraator complete of matching size, complete all as specified and as directed.
Material and labour for replacement of PVC chiller tray suitable for 165/170/180 ltrs capacity refrigerator complete of matching colour, complete all as specified and as directed.
Material and labour for replacement of PVC Accessories suitable for refrigerator of any model/ any size, complete of matching colour, complete all as specified and as directed.
Material and labour for patch work (in the outer body of refrigerator/Deep freezer with 20 gauge PGI sheet upto required length/width &hight incl necessary welding/brazing etc , complete all as specified and as directed.
Material and labour for replacement of refrigerator door handle of 165 to 320 Ltrs Cap. Of any make and model, complete all as specified and as directed.
Material and labour for repairing to bottom/ foundation of refrigerator any cap. With 20 gauge PGI sheet, angle iron frame made out of 25 X 25 X3 mm angle and incl necessary welding work , complete all as specified and as directed.
Material and labour for replacement of evaporator ( Freezer ) assy with door and fixing brackets complete with screw, jointing of tubes etc and testing of cap220 to 320 Ltrs refrigerator (any make), complete all as specified and as directed.
All as per ser item No 66 above but of capacity 165/180 Ltr refrigerator, complete all as specified and as directed.
Material and labour for replacement of condensor unit of refrigerator cap.280/ 286/310/320 Ltrs of any make incl jointing of tubes and testing etc, complete all as specified and as directed. (gas charging will be measure and paid under relevant item separately).
All as per ser item No 68 above but for 165/180/220 ltrs capacity refrigerator, complete all as specified and as directed.
Material and labour for leakage detection including flushing out system,pressurising,including gas charging(as per existing) suitable for 286/310 ltrs., complete all as specified and as directed.
Material and labour for leakage detection including flushing out system,pressurising,including gas charging (as per existing ) suitable upto 220 ltrs., complete all as specified and as directed.
Material and labour for leakage detection including flushing out system,pressurising,including gas charging(as per existing), including material and laying of copper cooling tubes if required suitable for 320/405 ltrs capacity Deep Freezers , complete all as specified and as directed.
Material and labour for sub main /Circuit wiring with 1.5 sq mm copper conductor cable 1100 volts grade conforming to relevant IS and ISI Marke including same size of earth wire and taking out old unserviceable sub main wiring including Making good to distrubed surface , complete all as specified and as directed.
Supply and replacement of condensor fan motor complete for deep freezer cap.310 to 405 ltrs. In existing location and position as per sample, complete all as specified and as directed.
Material and labour for replacement of timer frost free refrigerator as per sample, complete all as specified and as directed.
Material and labour for replacement of fan motor double door frost free refrigerator as per sample, complete all as specified and as directed.
Supply and replacement of PCB as per existing suitable for 220 to 320 Ltrs refrigerator/Deep Freezer , complete all as specified and as directed.
Material and labour for carefully dismentling of automatic voltage stablilzer electronic type of cap up to 3 KVA of any make including replacement of PCB and transformer complete kit reassembling and testing etc, complete all as specified and as directed.
Supply and replacement of 3 Pin Plug Top 06Amps ISI Marked 230 Volts , complete all as specified and as directed.
Material and labour for replacement of PVC Connection pipe ISI Marked 300m long heavy duty, complete all as specified and as directed.
Material and labour for replacement of PVC stop cock ISI Marked heavy duty, complete all as specified and as directed.
M & L for disconnecting, loading, unloading and transportation of Water coolers from existing location and position in A/A site for repairing of Water coolers of any make/capacity including reinstallation and testing at site after repairs , complete all as specified and as directed. NOTE : (i) Material required for defective / U/S parts shall be paid separately under relevent items.
M&L for checking of Water cooler of any make / capacity in location and position at any site in AA Jodhpur including necessary servicing i.e. making good electrical including copper terminal, cleaning , drain water system including replacement of hose clamp etc . complete , cleaning condensor , condenser fan motor , door gasket , cleaning storage water tank cleaning and testing for proper functioning ofwater cooler, complete all as specified and as directed.( The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no ,SM no. capacity, date of servicing , user signature after servicing , all as directed by Engineer in-charge )
Material and labour for replacement of unserviceable hermetically sealed compressor of water cooler 150 Ltr storage having cooling capacity 100 Ltrs / hour Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete all as specified and as directed. NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturing company (ii) The new unit will be purchased from authorised dealer only as per existing make and model.
All as per ser item No 84 above but for 60/120 Ltr storage capacity with cooling capacity 60 Ltrs / hour water cooler of any , complete all as specified and as directed.
All as per ser item No 84 above but for 40/80 Ltr storage capacity with cooling capacity 40 Ltrs / hour water cooler of any , complete all as specified and as directed.
Material and Labour for replacement of copper filter and capillary tube of water cooler cooling capacity 40 Ltr/hrs , complete all as specified and as directed.
Material and Labour for replacement of of cooper filter and capillary tube of water cooler cooling capacity 60 Ltrs per hour, complete all as specified and as directed.
Material and Labour for replacement of cooper filter and capillary tube of water cooler cooling capacity 100 Ltr per hour, complete all as specified and as directed.
Material and Labour for replacement of relay with over load protection for 40/80 Ltr/hrs cooling capacity suitable as per site requirement , complete all as specified and as directed.
Material and Labour for replacement of relay with over load protection for 60Ltr/hrs cooling capacity suitable as per site reuqirement , complete all as specified and as directed.
Material and Labour for replacement of relay with over load protections for 100 Ltr/hrs cooling capacity suitable as per site requirement , complete all as specified and as directed.
Material and Labour for replacement of condensor fan motor HP-1/32, RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan bladeISI marked, complete all as specified and as directed.
Material and Labour for replacement of condensor fan motor HP-1/16, RPM-1300 suitable for water cooler having cooling cap 60 to100 Ltr/hr with clips and motor fixing stand with fan blade ISI marked, complete all as specified and as directed.
Material and Labour for Repalcement of thermostat switch with knob for water cooler, having cooling capacity 40/60/150 Ltrs/hr , complete all as specified and as directed.
Material and Labour for patch repair work of worn out MS body of water cooler any capacity made out of 22 gauge mild steel sheet including welding and making good with paint to match with existing , complete all as specified and as directed.
Material and Labour for replacement of drain PVC pipe, 25 mm bore for cooling cap 40 Ltr /Hrs 90 cms in length with two Nos mild steel clamps and necessary brass screws etc. , complete all as specified and as directed.
All as per item No. 97 but size 32 mm bore suitable for cooling Cap 60 to 100 Ltrs/Hrs water cooler and not more than 1.00 meter , complete all as specified and as directed.
Material and Labour for replacement of SS drain water tray made out of 24 gauge stainless Steel sheet of size of 30x12x5 cm deep with necessary GI screws and PVC drain water connection arrangement of size not less than 25 mm dia, complete all as specified and as directed. (as per sample)
Material and Labour for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler storage cap 120 to 150 Ltrs , of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour , complete all as specified and as directed.
Material and Labour for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler cap 80Ltrs., platic sheet of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour all as specified and directed.
Material and Labour for replacement of rubber magnet gasket fixed with top cover of water cooler of 80/120 litres storage capacity, complete all as specified and as directed.
Material and Labour for replacement of rubber magnet gasket fixed with top cover of water cooler of 150 litres storage capacity, complete all as specified and as directed.
Material and Labour for replacement of worn out bottom base of water cooler foundation frame made out of 1.6mm thick MS sheet for water cooler, & frame work made out of angle iron25x25x3 mm, including cutting welding brazing soldering , making holes for sealed unit , condenser with condensor fan motor , including painting black colour ( two coats ) synthetic enamelled paint over a coat of red oxide primer etc and finishing , complete all as specified and as directed.
Material and labour for replacement of water cooler body back sheet with 22 gauge mild steel sheet including suitable size( as per existing) and necessary painting, screws etc. , complete all as specified and as directed.
Material and Labour for replacement of water cooler front pannel with 20 gauge mild steel sheet including suitable size( as per existing) and necessary screws/nuts/bolts/washers etc. for 40 ltrs/hour capacity , complete all as specified and as directed.
Material and Labour for replacement of condensor fan motor mounting stand made out of mild steel sheet 3 mm thick size 400x150 mm and refixing on the existing base , complete all as specified and as directed.
Material and labour for replacement of foundation stand of water cooler fabricated out of angle iron 25x25x3 mm 1600 mm in length incl. Welding and necessary fitting with patch work to bottom portion of 20 gauge MS sheet size 40x15 cm , complete all as specified and as directed.
Supply and fix CP lift cock, 15mm bore made of brass self closing vertical type made of brass nickle chromium plated alongwith CP adaptor and nipple, complete all as specified and as directed.
Supply and fix CP push cock, 15mm bore made of brass self closing horizontal type made of brass nickle chromium plated with CP adaptor and nipple , complete all as specified and as directed.
Material and labour for painting to water cooler of storage cap. 150/120/80 Ltrs spray painting with two coats of synthetic enamelled paint (first quality) including preparation of surface, complete all as specified and as directed.
Material and labour for repair to storage water tank of cooler of cooling cap 40 Ltr/hour by soldering / brazing to prevent leakage spots incl. cleaning of water tank and testing , complete all as specified and as directed. (NOTE : work is to be carried out in existing position as and where machine in army area)
Material and labour for repair to water tank cooler of cooling cap 60 Ltr/hour cap. by soldering, brazing to prevent leakage spots incl. cleaning of water tank and testing complete (NOTE : work is to be carried out in existing positio as and where machine lyes in army area )
Material and labour for repair to water tank of water cooler of cap. 150 ltrs/hrs, by soldering / brazing to prervent leakage spots incl. cleaning of water tank and testing , complete all as specified and as directed. (NOTE : Repairing to be done by the contractor at various location of units).
Material and labour for replacement of starting capacitor 40-60 Mfd oil filled 240 volt AC Supply , complete all as specified and as directed.
Material and labour for replacement of starting capacitor 60-80 Mfd oil filled 240 volt AC Supply , complete all as specified and as directed.
Material and labour for replacement of running capacitor of 15 Mfd oil filled , complete all as specified and as directed.
Material and labour for replacement of running capacitor of 10 Mfd oil filled, complete all as specified and as directed.
Material and labour for replacement of running capacitor of 2.5 Mfd oil filled , complete all as specified and as directed.
Material and labour for PVC float valve 15 mm bore with PVC float, ball ISI marked complete with check nut/socket/GI nipple , complete all as specified and as directed.
Material and labour for replacement of water cooler side panel with 20 gauge MS sheet as per sample incl. necessary screws/nuts/bolts/washers etc for 40/60/150 Ltrs/hour cap all as specified and directed by Engineer-in-Charge
Material and labour for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and gas (using as per existing ), oil complete incl testing and commissioning of water cooler having cooling Capacity 40 Ltrs per hour of any make, complete all as specified and as directed.
Material and labour for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and Gas (using as per existing ) chargE , oil complete incl testing and commissioning of water cooler having cooling Capacity 60 Ltrs per hour of any make, complete all as specified and as directed.
Material and labour for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and gas charging (using as per existing ), oil complete incl testing and commissioning of water cooler having cooling Capacity 100 Ltrs per hour of any make, complete all as specified and as directed.
Material and labour for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/hr water cooler, complete all as specified and as directed.
Material and labour for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 60/150 Ltr/hrs water cooler, complete all as specified and as directed.
Material and labour for replacement of condenser unit complete suitable for 40 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed , complete all as specified and as directed.
Material and labour for replacement of condenser unit complete suitable for 60 Ltr/hrs cap. Water cooler including gas chargin flushing out the system brazing, welding and jointing the suction reed and discharge reed , complete all as specified and as directed.
Material and labour for replacement of condenser unit complete suitable for 150 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed , complete all as specified and as directed.
Material and labour for replacement of PVC insulated and PVC sheathed flexible cable , multistranded copper conductor 3 core 1.50 sqmm cross sectional area superior quality, complete all as specified and as directed.
NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
Panwar Electricals
DIWAKAR CONSTRUCTION CO.
M/s R K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .