Tender Value
₹10.1 L
EMD Value
₹20,200
Closing Date
21 Feb 2022, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN- 160003
REPLACEMENT OF SPLIT TYPE ACS AND ALLIED WORKS AGAINST BER AND RENOVATION OF GATE AT LOWER MALL ROAD AT AF STN KASAULI
2022_MES_503637_1
GE(AF)/CHD/T-50/2021-22
Open Tender
Civil Works
Item Rate
180 days
Kasauli
All as per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹20,200
Yes
27 Apr 2022
25 Jan 2022
23 Feb 2022
25 Jan 2022
21 Feb 2022
8 Feb 2022
25 Jan 2022 - 31 Jan 2022
Amount
Taking down carefully existing unserviceable Air conditioner Window type/ Split (indoor unit, out door unit) of any capacity including Stablizer etc deposited to MES Store yard all as directed by Engineer-in-Charge.
Taking down carefully aluminIum/ copper point wiring for light, bell, fan, socket outlet, complete in all respect including fittings such as wooden battens junction boxes, round blocks bakelite sheets, and making good to the disturbed surface of wall, ceiling or floor etc to match with the existing specifications, all as specified.
Taking down existing DB TPN/SPN an type of any capacity including MCBs and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Supply and fix, testing and commissioning split type Air Conditioner single phase 240 Volts, 50 HZ capacity 2 TR with minimum 5 Star rating including necessary initial gas charging as required, fixing arrangement for blower unit and proper arrabgenent of outdoor compressor unit, (indoor/outdoor) complete with copper condenser cordless remote control unit and with in built air ionsier and Plasma filter for better indoor air quality all as directed. Make: Blue Star/Volta/Godrej
Supply and fix, testing and commissioning split type Air Conditioner single phase 240 Volts, 50 HZ capacity 1.5 TR with minimum 5 Star rating including necessary initial gas charging as required, fixing arrangement for blower unit and proper arrabgenent of outdoor compressor unit, (indoor/outdoor) complete with copper condenser cordless remote control unit and with in built air ionsier and Plasma filter for better indoor air quality all as directed. Make: Blue Star/Volta/Godrej
M/L Point wiring complete with 1100 volt grade PVC insulated unsheathed multistranded 4sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC conduit concealed size4 25/20 mm etc fixed in wall/celling including provision of 2.5 sqmm PVC unsheathed copper condutor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thich plastic laminated sheet top cover for housing switches sockets etc concealed on wall complete all as specified and directe by Engr-in-Charge.
Supply and fix Voltage stablizer for automatic operation, single phase naltuarally air cooled indoor type and designed for input variation between 170V to 240V with output voltage stablizer at 230V with accuracy of (plus minus) 2.5% and of capacity of 4KVA Make: V GUARD/MICROTEK/SINETRAC.
S & F Sheet metal enclosure single pole and neutral with a two pin socket and earth plug complete with one MCB single pole and 240V, 20 Amp 'C' curve 10 KA, complete all as specified.
Demolition of reinfoced concrete in gate pillars all as specified & directed
M &L PCC 1:1.5:3, type B-0 (12.5mm graded agregate) as in pillars all as specified & directed
S& F rolled steel sections frame work conforming to Fe 410-W (Gde E-250 quality A) including welded to plate, bolted in to PCC all as specified & directed.
M &L preparation of steel surfaces of any description above 10 cm width or girth not otherwise described with two coats of syn enamel paint over one coat of primer all as specified & directed
S&F coloured / transulent ACP sheet, 3 mm thick of approved colour and make compete all as specified & directed
S & F Stainless steel letters of size 200 mm with LED complete all as specified & directed
S & F Stainless steel Logo of size 300 mm with LED lights complete all as specified & directed
S & F Stainless steel pipe of 6mm thickness 100 mm dia (4.5 Kg /RM approx) with accessories in ornamental design fixed on PCC pillars complete all as specified & directed
S& F LED focus light 120 Watt 230V AC out door type with high pressure die cast aluminium hosing and heat resistant with driver, lamp brackets with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed on PCC pillars all as spd & directed
Vinod Kumar Aggarwal
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .