Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAdmitted-Fee/PreQual/Technical/Finance NOT SPECIFIED IN THE DOCUMENT | ₹10.3 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹10.6 LAdmitted-Fee/PreQual/Technical/Finance | ₹10.6 L | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | P. R. RIJESH L2 | EDISON ELECTRICAL ENGINEERING L1 |
|---|---|---|---|---|---|
| 1.00SITC OF ON grid Solar Power Plant | |||||
| 1.00 | OD273849/2025-2026:Supply, Installation, Testing, and Commissioning of 15.2 kW on-grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:a) Solar Photovoltaic Module of capacity 545 Wp or above, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories, etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, a main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.g) Statutory fees such as KSEB Fees (Application Fee, Registration fee & Liasioning Fee),Electrical Inspectorate Liasioning Fee, Net meter - HT(Including Testing/Calibration Liasioning Fee) etc is included in this proposal. Brand - Havells /equivalent. | 1 | each | 9,39,000 ₹9,39,000 | 9,19,000 ₹9,19,000 Lowest |
| 1.00 | OD273851/2025-2026:Providing structure work required for installation of Solar plant with purlin / single section with GI round / rectangular pipes including cutting , hoisting , fixing in position and two coat painting with suitable paint over a coat of approved steel primer , including welding and bolted with special shaped washers etc complete as required . | 58 | kg | 700 ₹40,600 | 600 ₹34,800 Lowest |
| 1.00 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board | 50 | kg | 100 ₹5,000 Lowest | 100 ₹5,000 Lowest |
| 1.00 | 90.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp | 55 | metre | 400 ₹22,000 Lowest | 400 ₹22,000 Lowest |
| 1.00 | 90.12.39.36:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 35 sq mm | 75 | metre | 400 ₹30,000 Lowest | 400 ₹30,000 Lowest |
| 1.01 | 9.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.4 X 35 sq. mm (32mm) | 2 | set | 700 ₹1,400 | 600 ₹1,200 Lowest |
| 1.01 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size | 77 | metre | 50 ₹3,850 Lowest | 50 ₹3,850 Lowest |
| 1.01 | 14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia | 4 | metre | 500 ₹2,000 | 400 ₹1,600 Lowest |
| 1.01 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) | 256 | metre | 55 ₹14,080 Lowest | 55 ₹14,080 Lowest |
Tender Value
₹10.6 L
EMD Value
₹26,509
Closing Date
19 Aug 2026, 6:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer, PWD electricalsubdivision kasaragod
Electrical works
2026_PWD_865211_1
PWD/BLDG/TR/15801/2025_6_2_1/1
Open Tender
Electrical Works
Item Rate
Vidyanagar
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
₹26,509
22 Aug 2026
11 Aug 2026
22 Aug 2026
11 Aug 2026
19 Aug 2026
11 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC OF ON grid Solar Power Plant | |||||
| 1.001 | OD273849/2025-2026:Supply, Installation, Testing, and Commissioning of 15.2 kW on-grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:a) Solar Photovoltaic Module of capacity 545 Wp or above, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories, etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, a main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.g) Statutory fees such as KSEB Fees (Application Fee, Registration fee & Liasioning Fee),Electrical Inspectorate Liasioning Fee, Net meter - HT(Including Testing/Calibration Liasioning Fee) etc is included in this proposal. Brand - Havells /equivalent. | - | each | - | - |
| 1.002 | OD273851/2025-2026:Providing structure work required for installation of Solar plant with purlin / single section with GI round / rectangular pipes including cutting , hoisting , fixing in position and two coat painting with suitable paint over a coat of approved steel primer , including welding and bolted with special shaped washers etc complete as required . | - | kg | - | - |
| 1.003 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board | - | kg | - | - |
| 1.004 | 90.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp | - | metre | - | - |
| 1.005 | 90.12.39.36:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 35 sq mm | - | metre | - | - |
| 1.006 | 9.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.4 X 35 sq. mm (32mm) | - | set | - | - |
| 1.007 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size | - | metre | - | - |
| 1.008 | 14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia | - | metre | - | - |
| 1.009 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) | - | metre | - | - |
stage.html
html • 0.02 MB
finance_1464113.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewsbd.pdf
Tender Documents • 1.80 MB
BOQ_1464113.xls
BOQ • 0.31 MB
materialslist.xls
Additional Documents • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].