Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Admitted-Finance |
| 5 | Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹35,500
Closing Date
27 Dec 2022, 11:30 amClosed
EEEANDMM-5
EEEANDMM-5
Improvement of main LT panel installed at Pahadi Dheeraj new pumphouse by replacement of existing old and faulty panel.
2022_DJB_233545_1
NIT NO. 19 (2022-2023)
Open Tender
Miscellaneous Services
Item Wise
30 days
EEEANDMM-5
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹35,500
6 Jan 2023
21 Dec 2022
27 Dec 2022
21 Dec 2022
27 Dec 2022
21 Dec 2022
Dismantling of old main LT panel including removing of all electric connections while taking all safety precautions and cutting of old rusted nuts and MS bar with help of electric cutter/ manual labour including excavation of soft / hard soil upto 100 mm and making the surface even for laying foundation for new panel as per site requirement.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement for the base of main incomer distribution panel, including cement slurry as per site requirement and directions of engineer in charge
S/o of 1250 A 4 pole draw out type ACB with frame and thermal magnetic release and breaking capacity of 50 kA equivalent to C-power series of L&T, including MDO type WITH mtx1.5g 50 KA (with LSING protection & display) with both side terminal adapter, (1) under voltage coil, channels, rails required for installation. Make: L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
S/o Moulded Case Circuit Breaker (MCCB) of rating 630 Amp, Four Pole, 415 V, AC of breaking capacity of 36 kA or more with Spreader Link/ terminals. Make: Havells/Selec/ L&T/ Schneider/ Indocop/ C&S/ Siemens( 1 spare)
S/o Moulded Case Circuit Breaker (MCCB) of rating 400 Amp, Four Pole, 415 V, AC of breaking capacity of 36 kA or more with Spreader Link/ terminals. Make: Havells/Selec/ L&T/ Schneider/ Indocop/ C&S/ Siemens. (1 spare)
S/o Moulded Case Circuit Breaker (MCCB) of rating 200 Amp, Triple Pole, 415 V, AC of breaking capacity of 36 kA or more with Spreader Link. Make:Havells/Selec/ L&T/ Schneider/ Indocop/ C&S/ Siemens
TP Air Break Contactor 140 Amps Coil Voltage 240 Make Make: - L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
TP Air Break Contactor 110 Amps Coil Voltage 240 Make Make: - L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
Star Delta Timer 0-20 Sec,240 Voltage Make: - L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
Microprocessor based Motor Protection Device having following protection : Over Voltage/Under voltage/Single phase /Phase reversal/over current/under current Protection/ Earth fault. Make:- L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
TP thermal overload Relay Range 90-150 A, suitable for above contactors Make: - L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
S/o PVC insulated copper flexible cable single core 70 sqmm. Make: Havells / Fort Gloster / ICC /CCI/ Grandlay/ Universal/ ICL
S/o Ampere Meter 800/5 Amp. Digital type. Make: - L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
S/o Ampere Meter 300/5 Amp. Digital type. Make: - L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
S/o Voltmeter Digital type Make: - L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
S/o Current Transformer 800/5 Amp. Digital type. Make: - L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
S/o Current Transformer 300/5 Amp. Digital type.Make:- L&T, Schneider, Siemens, C&S, ABB, GE, EE, BCH, HPL, SUBTECH, RST
SP MCB. 6A. Make Havells/Selec/ L&T/ Schneider/ Indocop/ C&S/ Siemens
On/Off Push Button 22.5 Make: - Warner/ Selec/ L&T/ HPL
S/o Indicating Lamp, Led type Make: - IEC/ L&T/C&S/ Havell's/Siemens
S/o PVC insulated copper flexible cable three core 10 sqmm. Make: Havells / Fort Gloster / ICC /CCI/ Grandlay/ Universal/ ICL
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required upto 35 sqmm clamped with 1 mm thick saddle. DSR 2022 7.7.1
Installation of the new L.T. Panel at site including providing of the all material required for fixing the panel in the newly laid foundation including grouting and minor civil work as per satisfaction of engineer in charge.
Making the Required incoming power supply connections between main supply and new incomer panel by connecting the cable after relaying of cable and re thimbling of cable ends as per requirement.
Testing & commissioning of the new starter panels including testing for their manual/ automatic operations for the pumps as after making required configurations for the automatic operations in the starters. Testing of Starters at No Load and then at on Load. Testing of tripping system of starters as per requirement and directions of engineer in charge
Premier Engineering Company
MITTAL TRADING COMPANY
HARI ELECTRICAL CO.
Super System Engineers
CHANDERA BUILDERS
Volts And Watts Electronics Pvt. ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .