| 1 | L-1₹22.5 LAccepted-AOC MINISTRY OF DEFENCE MES JALPAIGURI WEST BENGAL | BANKURA | WEST BENGAL | 713142 | ₹22.5 L Quoted ₹22.9 L | L-1 | Accepted-AOC Being L 1 |
| 2 | L-2₹25.4 L+₹2.6 L (11.2%)Rejected-Finance PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | ₹25.4 L+₹2.6 L (11.2%) | L-2 | Rejected-Finance Being L 2 |
| 3 | L-3₹26.7 L+₹3.8 L (16.5%)Rejected-Finance BANKIM CHANDRA ROAD HAKIMPARA SILIGURI DIST DARJEELING PIN 734001 W B | JALPAIGURI | WEST BENGAL | 734001 | ₹26.7 L+₹3.8 L (16.5%) | L-3 | Rejected-Finance Being L 3 |
| 4 | L-4₹27.0 L+₹4.1 L (18.1%)Rejected-Finance TELEPARA HATKHOLA PO BINNAGURI 735203 DISTT JALPAIGURI W B | JALPAIGURI | WEST BENGAL | 735203 | ₹27.0 L+₹4.1 L (18.1%) | L-4 | Rejected-Finance Being L 4 |
| 5 | L-5₹27.0 L+₹4.2 L (18.2%)Rejected-Finance DEPOPARA PO BINNAGURI PS BANARHAT DIST JALPAIGURI WEST BENGAL PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | ₹27.0 L+₹4.2 L (18.2%) | L-5 | Rejected-Finance Being L 5 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
2 Oct 2021, 6:00 pmClosed
GE North Binnaguri
Post Binnaguri Dist Jalpaiguri West Bengal
SPECIAL REPAIRS TO BUILDING NO OTM 04 UNDER GE NORTH BINNAGURI
2021_MES_474037_1
NIT No. 8701/ 55 / 2021-2022 / 02 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
BINNAGURI
Class D Category a i
8 documents required · 8 mandatory
₹500
Yes
GE North Binnaguri
₹66,000
Yes
10 Nov 2021
9 Sept 2021
4 Oct 2021
9 Sept 2021
2 Oct 2021
20 Sept 2021
Amount
SCHEDULE `A' ( CIVIL WORK) Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm each etc including removing material from work site complete all as specified and directed.
Taking down chowkats with shutter (without taking off shutter from the frame) n. exc 1.50 Sqm each etc including removing material from work site complete all as specified and directed.
Supply and fixing of pressed steel framed for door with one or more rebates including necessary fixing lugs, hinges, lock strike plates, size of frame 125 X 60 mm, 1.6 mm thickness of sheet, complete all as specified and as directed.
Supply and fixing of 35mm thick 2nd class hard wood factory made, plain, framed, panelled shutter (two panel) with lock rails and panel of 9mm BWP comercial ply or 12 mm thick veneered particle board with comercial veneering on both faces. The size of rail and style as per IS-1003 Part-I klin seasoned and chamicaly pressure treated complete all as specified and as directed.
Supply and fixing of 35mm thick factory made 2nd class hard wood gauged and skeleton shutter open rebated and prepared to receive glass , gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitred beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 clause No.8.23(a) and fitted to chowkats complete all as specified and as directed.
Supply and Fixing solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supply & fixing in opening as per specification & drawing and as directed.
Supply and Fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side as gap insert for top rails bottom rail, panelling of plain colour PVC sheet to be fitting in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drg and as directed.
Supply and fixing of 100 mm long medium weight, cold rolled mild steel butt hinges complete all as specified and directed.
Supply and Fixed of 100 mm long medium weight, stainless steel butt hinges complete all as specified and directed.
Supply and fixing 150 mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified.
Supply and fixing 150 mm size aluminium, anodised, barrel tower bolts of extruded section and fixed, complete all as specified.
Supply and fixing in repairs 150 mm size black jappen painted mild steel handle oval type complete all as specified.
Supply and fixing 250 mm long Aluminium alloy. Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified.
Supply and fixing for factory made steel window with side hung shutters including projecting type hinges with steel handles, and steel peg stay, fixing lugs complete with glazing bar devetailed or welded including one shop coat of red oxide primer compete all as specified and as directed.
Supply and fixing for factory made steel window with side hung shutters including projecting type hinges with steel handles, and steel peg stay, fixing lugs complete without glazing bar devetailed or welded including one shop coat of red oxide primer compete all as specified and as directed.
Supply and fixing for Steel windows, fixed type, with glazing bars bar devetailed or welded including one shop coat of red oxide primer compete all as specified and as directed.
Supply and fixed mild steel framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290-Gde E-165 complete all as specified and directed.
Supply and fixing in repair factory made steel ventilator top hung shutter including hinges, steel peg stay, fixing lugs etc complete with or witthout glazing bar devetailed or welded including one shop coat of red oxide primer compete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete including removing dismantled material from work site all as specified.
Supply and fixed mild steel in framed work as in doors frame of angle or other section conforming to Fe 410-W(Gde-E-250) quality-A with gusset plates, rails, braces, etc,. and including fixing of steel hinges or other door fittings complete all as specified and as directed.
Material and labour for preparation of untreated new wooden surface of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint, (1st quality) with a coat of pink primer all as specified and directed.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint (1st quality) over one coat of red oxide Zinc chrome primer complete all as specified.
Hacking out old broken glass ( any thickness , size , quality or description) from wooden/metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads upto 1.5 sqm complete all as specified.
Supply and fixing 3 mm thick (nominal) Sheet glass, ordinary quality , figured glass, pin head type and glazing with oil putty in squares n exc 0.50 sq.m. in each pane complete all as specified.
Supply and fixing 3 mm thick figured glass, pin head type and ordinary quality , in squares, not exceeding 0.50 sqm each each pane fixed with oil putty complete all as specified.
Material and labour for plain cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in fixing of hold fast ,bed blocks parapet, cills, coping, and similar works including necessary form work as required complete all as specified and as directed.
Supply and fixed stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fixed in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc.including removing of rubbished material from work site complete all as specified.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces , in cement and sand mortar 1:4 using water liquid water proofing compound @ 200 ml per bag of cement or as per manufacturer's instructionscomplete all as specified top surfaces finished even and smooth without using extra cement complete all as specified. (WPC shall be measured and paid separately)
Material and Labour for rendering 15 mm thick on other than fair faces of brick or concrete surfaces finishing surfaces even and smooth without using extra cement in Cement mortar 1:6 all as specified and directed.
Material and labour for rendering 5mm thick on concrete surfaces in ceiling , in cement and sand mortar 1:3 finishing surfaces even and smooth without using extra cement complete all as specified
Supply only Integral liquid water proofing compound conforming to IS-2645-2003 complete all as specified.
Material and labour for preparation of new plastered or unplastered surafces of wall and applying three coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour fo preparation of new plastered or unplastered surafces of ceilings and applying three coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of new/untreated surfaces/ of walls and applying two coats of colour wash over a coat of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of walls by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surfaces of walls including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of walls by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of colour wash on old decorated surfaces of walls including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), in floors, aprons etc .laid dry or laid dry and pointed including removing of demolished material from work site at any distance outside MD land complete all as specified and directed.complete all as specified.
Material and labour for Non Skid ceramic coloured tiles (1st quality) 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screeding in CM 1:6 complete all as specified (Note : screed bed shall not be measured and paid separately).
Material and labour for glazed ceramic coloured / digital printed of size (300 x 200 mm / 300 x 450 mm x 7 mm thick ) as in vertical surfaces such as skirting/dado / riser to steps etc conforming to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including cement screed bed / backing layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed. (Note : screed bed shall not be measured and paid separately).
Roughening surfaces of old concrete floor/ verticle surface by picking, sweeping clean and washing down with water to remove dust etc.and prepare the surface to receive tiles including applying 3Kg/Sqm cement slurry complete all as specified and directed.
Material and labour for machine cut Kota stone slab as in flooring, 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20 mm thick plaster as screed bed in CM 1:6 complete all as specified.( Note Screed bed shall not be measured and paid separately).
Material and labour for machine cut Kota stone slab as in skirting / dado verticle surface 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 10 mm thick plaster as screed bed in CM 1:4 complete all as specified.( Note Screed bed shall not be measured and paid separately).
Demolition of cement concrete ( unreinforced ) in ground floors and pavings not exceeding 15 cm thick above or below ground level, including removing of demolished material from work site at any distance outside MD land complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection; pathway / hardstanding etc laid in bays / panels not exc. 2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extra cement complete all as specified.
Taking up or down steel tubing and connections, including cleaning for re-fixing and removal of unserviceable pipe from work site,15 mm bore dia all as directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing and removal of unserviceable pipe from work site, 20 mm bore dia all as directed.
Supplying , laying, jointing and testing 15 mm nominal bore Steel water tubes, 'medium grade' ,galvanised , with all fittings ; fixed to walls and ceilings or laid in floors complete all as specified.
Supplying , laying, jointing and testing 20 mm nominal bore Steel water tubes, 'medium grade' ,galvanised , with all fittings ; fixed to walls and ceilings or laid in floors complete all as specified.
Refixing old steel tubing and connections in new or old position ( walls, ceiling , floors, etc.)15 mm nominal bore dia, including new fittings complete all as specified ( Note:- Refixing means including cleaning down existing pipes and fittings. )
Cutting chases in brick work, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades,shelves, lintels,etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc.,and making good, cutting not exc 10 cm girth complete all as specified.
Supply and fixed rotational moulded poly-ethylene multilayer water storage tanks ( cylinderical vertical with closed top ) 1000 litres capacity ,hoisted and fixed in position complete all as specified including dismantling PVC water tanks, including removing ball valve and removing unserviceable tank from work site complete all as specified
Supply and fixed ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete , screwed for 20 mm bore dia. pipe or brass ferrule complete all as specified.
Supply and fixed in repair PTMT ( Polytetra Methyllene Terephthalate ) Bib taps suitable for 15 mm bore pipe long body of PTMT any colour screwed, for iron pipe and fixed ( (Minimum weight 15mm-120gms) complete all as specified .
Supply and fixed in repair, CP stop cock ( concealed type) long fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified
Supply and fixed in repairs Swivel shower with shower arm 15mm size,195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gmsof PTMT complete all as specified.
Supply and fixed in repairs vitreous china wash basin (WHB) , white , flat back , size 550 mm x 400 mm (1st quality) including brackets, waste fittings , brass Chromium plated for glazed basins etc. with long screw shanks and fly nuts , flange end embedded in red lead cement , including cutting for and pinning in ends of brackets or erecting stand but but incl providing brackets, waste pipe & CP waste coupling complete all as specified and as directed.
Supply and fixed in repair, pillar taps, fancy type, cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified.
Supply and fixed in repairs vitreous china white Squatting pan ,'Orissa' pattern size 580x440mm with integral footrests water closet) with 'P' or 'S' trap front or back inlet complete including lime concrete for bedding, connection to drain pipe and to flushing pipe , anti syphonage pipe etc complete all as specified.
Supply and fixed in repairs low level flushing cistern (dual-flush), 9-10 litres capacity ISI marked embossed moulded from virgin poly propylene valveless, syphonic ac-tion type, low level, white, with inlet, ball valve, float and handle including brackets including flush pipe complete all as specified and directed.
Supply and fixed in repairs of Vitreous China bowl urinal flat back, size of 465x355x265 mm White ( minimum) including providing and fixing plugs, bedding the urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement and providing grating and union for discharge pipe including 32mm bore PVC discharge pipe complete all as specified and as directed.
Supply and fixing in repairs CP angular cock cast copper alloy with flange , 15 mm bore dia screwed both end high pressure complete all as specified.
Supply and fixing in repairs CP Brass Tubular towel rail, 20 mm dia. D type, 60 cm long between flanges fixed in position with CP brass screws complete all as specified.
Supply and fixed in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement, 75 mm dia. outlet complete all as specified.
Demolition and breaking up drain pipes ( salt glazed ware, AC or Reinforced concrete/SWR ) set in cement mortar of 75mm/100mm dia bore and removal of unserviceable pipe from work site,all as directed.
Supply and fixed of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified.
Supply and fixed for 110mm dia PVC (SWR) bend of any radius for PVC (SWR) pipes, fixed to walls complete all as directed.
S&F PVC ( SWR) junction single , ( Single T) equal or unequal 110 mm bore with access door complete all as specified.
Supply and fixed for 110mm dia PVC (SWR) branch piece, (single ‘Y‘) equal or unequal complete all as specified and as directed.
Demolition of Cement concrete ( reinforced) of any description and in any position not otherwise specifically provided for including reinforced cut to facilitate demolition complete including removing demolished material from work site all as specified and directed.
Material and labour for reinforced Cement concretetype A-1 (1:1.5:3), 20 mm graded stone aggregate) as inin slabs supported on walls, beams and columns , in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified..
Material and labour for use and waste form work to sides of fins, louvers, fascia and similar work; vertical or to batter) surfaces fair finished complete all as specified.
M&L Mild steel bars ( TMT) 8mm dia. and over up to and including 10 mm dia. in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips complete all as specified.
Demolition of existing mud roof treatment complete of any description and taking down existing tarfelt including tiles, lime concrete and screed bed complete from roof surfaces including parapets and lowering and removing the same to a distance exc. 500 mtr and not exc. 1000 meter, cleaning the surface by wire brushing to remove all loose dust etc complete all as specified and directed.
Material and labour for plain cement concrete type B-0 (1:2:4), using 12.5 mm graded crushed stone aggregate, in roof kerbs or mud stops, rounded or cmamfered on edges complete all as specified.
Material and labour for 10 mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces finished even and smooth without using extra cement for receiving treatment complete all as specified and directed.
M&L for water proofing treatrment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bitumenous primer @ 0.4 ltrs per Sqm over plastered surfaces of roof incl parapet surface. (b) Over the priming coat laying one layer APP based polymembric membrane of approved manufacturer 3 mm thick weight not less than 3.6 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i) Laying APP bassed polymenic membrane shall be done torch on methed or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (iii) Applying two coats of Aluminium paint over APP membrane.) (iv) Treatment shall be done by authorise applicator of the firm (v) Cutting groove in brick wall 75 mm wide & 65 mm deep and sloping horizontal face of groves with cement mortar 1:3 (vi) APP water proofing work shall be carried out through from authorized applicator of manufacturer and approved by GE in writing.
INTERNAL ELECTRIFICATION Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
Material & Labour for consealed type point wiring with 1.50 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable of working voltage 1100 volts grade conforming to IS-694 Pt I & II of 2000 drawn through and including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification), including provision of 1.5 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable as earth continuity conductor, connected to main switch / DBs or common earth dolly for one light / fan point / exhaust point/bell push point controlled by one 5 Amps one way switch complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No.82 here-in-before but for one socket out let 5/6 amps point on the independent board
All as per item No.82 here-in-before bu above but one socket out let 5/6 amps point on the same board complete all as specified.
Material and labour wiring for 5/6 pin 6/16 Amp switch socket combination on independent boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FR earth wire and connecting to earth dolly and brass screws, washers etc. including cutting chases pinning in for concealed conduit wiring and making good of disturbed surface n exc 15 cm girth complete all as specified.
Supply and fixed switch piano flush type, single pole , 6 Amps, one way complete all as specified.
Supply and fixed socket 2 in 1 , 5/6 amps, flush type complete all as specified.
Supply and fixed switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified.
Supply and fixed switch socket combination 2 in 1 , 6 pin , 5/6 amps and 15/16 amps multipurpose, of any type complete all as specified.
Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply & fixed lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified.
Supply & fixed stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified .
Supply & fixed LED white glass Lamp 1x 9 Watts, 230V Base-22 complete all as directed.
Supply and fixing in repairs of LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as specified and directed.
Supply and fixed in repairs new generation energy saving and environmental friendly long life LED street light fitting with 25 watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening including separate driver comportment with IP 66 protection & impart resistance of IKO7 with operating voltage range of 140V to 270 V olts, 110 Lumen per watt complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose to fittings and GI pipe bracket made out of GI pipe medium grade 32mm dia 1.5 mtr long bend to required shape complete all as specified.
Materials and labour for Sub main wiring with 2 runs of 6.00 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FRLS) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly, drawn through and including PVC rigid non- metallic PVC conduit / casing and capping ISI marked , medium garde of adequate size with all conduit / casing and capping accessories ISI marked as required complete all as specified and as directed including taking down old unserviceable / burnt / damaged one. [NOTE : Two run of sub main wiring cable along with one run of earth wire and one run of PVC Conduit / casing and capping shall be measured as one length]
Taking down ceiling fan any size from its location including disconnecting from ceiling rose, after removing carefully false celing/ ceiling wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and bottom cover in position; washing body, blades, canopies with detergent soap powder; preparation of old painted surfaces by filling cavaties with suiatble filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re - hanging fan and false ceiling in position and making electric connection complete all as directed.
Supply and fixed of sheet metal enclosure for 8 way Distribution Boards (DB’s), double door , single pole and neutral with 200 amps rated bus bar, including bus bar neutral link, earth bar and din rail, IP-43, IK-09 protection including gasket and door earthing suitable for fixing MCBs/isolators fixed on wall surface and making good the disturbed surfaces of wall and connecting up including taking down old unserviceable one including MCBs complete all as specified and as directed.
Supply and fixed MCB SPN 35 to 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SP 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Material and labour for Earthing complete with galvanised mild steel earth plate electrode 600 mm x 600 mm x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 20 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
L. B. SHARMA
M/s. MD IRSHAD
M/S MAJUMDER CONSTRUCTION
M/S MOHAN KUMAR BANSAL
R K AGARWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .