Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 CrAccepted-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L1 | Accepted-AOC Award | |
| 2 | L2₹16.5 Cr+₹13.9 L (0.85%)Rejected-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | L2 | Rejected-AOC Reject | |
| 3 | L3₹17.4 Cr+₹1.1 Cr (6.81%)Rejected-AOC 52 SHANTI NAGAR MODEL TOWN PANIPAT OPPOSITE AMAR STEEL SHUTTERING WORKS 132103 | PANIPAT | PANIPAT | HARYANA | 132103 | L3 | Rejected-AOC Reject | |
| 4 | L4₹19.3 Cr+₹2.9 Cr (17.9%)Rejected-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L4 | Rejected-AOC Reject | |
| 5 | L5₹21.9 Cr+₹5.6 Cr (34.2%)Rejected-AOC 14 CHAHAR CONSTRUCTION CO ADARSH NAGAR NEAR ROHILLA COMMUNICAION 124103 | JHAJJAR | HARYANA | 124103 | L5 | Rejected-AOC Reject |
| Sl No | Description | Qty | Unit | Jai Shree Balaji Constn Co. L3 | M/S SHREE BALAJI BUILDERS L6 | Chahar Construction Co L5 | ROHTASH KUMAR CONTRACTOR L2 | RAJEEV KUMAR GOEL CONTRACTORS L4 | Rajesh Kadiyan Contractor L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (150 Sqmm size) | 30 | Per Mtr | 19,000 ₹5,70,000 | 13,857.09 ₹4,15,712.7 | 13,407.92 ₹4,02,237.6 | 4,000 ₹1,20,000 Lowest | 11,782 ₹3,53,460 | 7,000 ₹2,10,000 |
| 2.00 | PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
2500 LPM x 15 Mtr. Head | 1 | Each | 80,000 ₹80,000 | 1,01,146.58 ₹1,01,146.58 | 97,868 ₹97,868 | 90,000 ₹90,000 | 86,000 ₹86,000 | 40,000 ₹40,000 Lowest |
| 3.00 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. (25 Sqmm size) | 30 | Per Mtr | 3,000 ₹90,000 | 2,276.98 ₹68,309.4 | 2,203.17 ₹66,095.1 | 1,000 ₹30,000 Lowest | 1,936 ₹58,080 | 1,100 ₹33,000 |
| 4.00 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. (35 Sqmm size) | 60 | Per Mtr | 3,000 ₹1,80,000 | 3,154.37 ₹1,89,262.2 | 3,052.12 ₹1,83,127.2 | 1,200 ₹72,000 Lowest | 2,682 ₹1,60,920 | 2,000 ₹1,20,000 |
| 5.00 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. (70 Sqmm size) | 30 | Per Mtr | 7,000 ₹2,10,000 | 6,132.3 ₹1,83,969 | 5,933.53 ₹1,78,005.9 | 2,500 ₹75,000 Lowest | 5,214 ₹1,56,420 | 3,500 ₹1,05,000 |
| 6.00 | Providing, fixing, jointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, transportation ets up to the site. (200 mm nominal diameter) | 2 | No. | 4,000 ₹8,000 Lowest | 4,822.1 ₹9,644.2 | 4,665.8 ₹9,331.6 | 5,500 ₹11,000 | 4,100 ₹8,200 | 4,100 ₹8,200 |
| 7.00 | National high way crossing by Trenchless (Arya Nagar): Boring, excavation by trenchless adopting HDD method (Horizontal Directional Drilling) below ground at all depth Including carriage etc. complete in all respect, construction of thrust pit and receiving pit of required size and depth and soil investigation making suitable arrangement for barricading of pits, traffic diversion, lights, refilling of pits in compacted layers of 150 mm including disposal of surplus material with all lift and lead up to 50 meter as per specification and the direction of the Engineer including provision of probe radar survey to check any underground obstruction before start of work. Manual Pipe jacking is not permitted for workmen safety reasons.
Providing and insertion of 500 mm i/d M.S. casing pipe 8 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 and also coating of inner and outer surface of casing pipe with high built epoxy paint as per R.D.S.O. specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion including cost and cartage of material to site of work complete in all respect as per specification given in DNIT.
Providing, lowering, laying in trenches, aligning, fixing in position and jointing HDPE pipe PN-6 355 mm dia by Roller arrangement for smooth insertion and anchoring of pipe throughout the length with HDPE spacers at a distance of 2 meters apart to avoid contract of carrier pipe including cost of HDPE Special complete in all respect. (For Arya Nagar Rohtak road) | 25 | Meter | 30,000 ₹7,50,000 | 31,060.23 ₹7,76,505.75 | 30,053.44 ₹7,51,336 | 25,000 ₹6,25,000 Lowest | 26,409 ₹6,60,225 | 26,000 ₹6,50,000 |
| 8.00 | National high way crossing by Trenchless (Miglani Colony): Boring, excavation by trenchless adopting HDD method (Horizontal Directional Drilling) below ground at all depth Including carriage etc. complete in all respect, construction of thrust pit and receiving pit of required size and depth and soil investigation making suitable arrangement for barricading of pits, traffic diversion, lights, refilling of pits in compacted layers of 150 mm including disposal of surplus material with all lift and lead upto 50 metre as per specification and the direction of the Engineer including provision of probe radar survey to check any underground obstruction before start of work. Manual Pipe jacking is not permitted for workmen safety reasons.
Providing and insertion of 500 mm i/d M.S. casing pipe 8 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 and also coating of inner and outer surface of casing pipe with high built epoxy paint as per R.D.S.O. specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion including cost and cartage of material to site of work complete in all respect as per srecification given in DNIT.
Providing, lowering, laying in trenches, aligning, fixing in position and jointing HDPE pipe PN-6 355 mm dia by Roller arrangement for smooth insertion and anchoring of pipe throughout the length with HDPE spacers at a distance of 2 meters apart to avoid contract of carrier pipe including cost of HDPE Special complete in all respect. (For Miglani Colony) | 25 | Meter | 30,000 ₹7,50,000 | 31,060.23 ₹7,76,505.75 | 30,053.44 ₹7,51,336 | 25,000 ₹6,25,000 Lowest | 26,409 ₹6,60,225 | 26,000 ₹6,50,000 |
| 9.00 | Trenchless Crossing (For R/M Shani Mandir Disposal): Boring, excavation by trenchless adopting HDD method (Horizontal Directional Drilling) below ground at all depth Including carriage etc. complete in all respect, construction of thrust pit and receiving pit of required size and depth and soil investigation making suitable arrangement for barricading of pits, traffic diversion, lights, refilling of pits in compacted layers of 150 mm including disposal of surplus material with all lift and lead upto 50 metre as per specification and the direction of the Engineer including provision of probe radar survey to check any underground obstruction before start of work. Manual Pipe jacking is not permitted for workmen safety reasons.
Providing and insertion of 200 mm i/d M.S. pipe 8 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 and also coating of inner and outer surface of casing pipe with high built epoxy paint as per R.D.S.O. specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion including cost and cartage of material to site of work complete in all respect as per srecification given in DNIT. (For Disposal Shani mandir) | 25 | Meter | 18,000 ₹4,50,000 | 10,055.85 ₹2,51,396.25 | 9,729.9 ₹2,43,247.5 | 10,000 ₹2,50,000 | 8,550 ₹2,13,750 Lowest | 8,600 ₹2,15,000 |
| 10.00 | NON CLOG SEWAGE PUMP: Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head below mentioned as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked.
`13000 LPM x 20 Mtr. Head | 1 | Each | 8,50,000 ₹8,50,000 | 9,46,779 ₹9,46,779 | 9,16,090 ₹9,16,090 | 9,00,000 ₹9,00,000 | 8,05,000 ₹8,05,000 | 8,00,000 ₹8,00,000 Lowest |
Tender Value
₹19.3 Cr
EMD Value
₹38.5 L
Closing Date
10 Jun 2026, 11:00 amClosed
NAVEEN KUMAR GOYAT
Gohana PHED No. 1
GOHANA TOWN SEWAGE SCHEME- Laying the sewerage network, House sewer connection, Const of manholes, laying the Rising main line and installation of PM at Disposal Shani mandir and MPS Gudha at Gohana Town including defect liability period of 3 years
2026_HRY_522993_1
2026E421E6FD 4623 49D5 8B12 CE161E7337F5589PUH
Open Tender
Civil Works
Works
450 days
Gohana
2 documents required · 2 mandatory
₹20,000
₹38.5 L
Yes
25 Sept 2026
20 May 2026
10 Jun 2026
20 May 2026
10 Jun 2026
20 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (150 Sqmm size) | 30 | Per Mtr | - | - |
| 2 | PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
2500 LPM x 15 Mtr. Head | 1 | Each | - | - |
| 3 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. (25 Sqmm size) | 30 | Per Mtr | - | - |
| 4 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. (35 Sqmm size) | 60 | Per Mtr | - | - |
| 5 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. (70 Sqmm size) | 30 | Per Mtr | - | - |
| 6 | Providing, fixing, jointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, transportation ets up to the site. (200 mm nominal diameter) | 2 | No. | - | - |
| 7 | National high way crossing by Trenchless (Arya Nagar): Boring, excavation by trenchless adopting HDD method (Horizontal Directional Drilling) below ground at all depth Including carriage etc. complete in all respect, construction of thrust pit and receiving pit of required size and depth and soil investigation making suitable arrangement for barricading of pits, traffic diversion, lights, refilling of pits in compacted layers of 150 mm including disposal of surplus material with all lift and lead up to 50 meter as per specification and the direction of the Engineer including provision of probe radar survey to check any underground obstruction before start of work. Manual Pipe jacking is not permitted for workmen safety reasons.
Providing and insertion of 500 mm i/d M.S. casing pipe 8 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 and also coating of inner and outer surface of casing pipe with high built epoxy paint as per R.D.S.O. specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion including cost and cartage of material to site of work complete in all respect as per specification given in DNIT.
Providing, lowering, laying in trenches, aligning, fixing in position and jointing HDPE pipe PN-6 355 mm dia by Roller arrangement for smooth insertion and anchoring of pipe throughout the length with HDPE spacers at a distance of 2 meters apart to avoid contract of carrier pipe including cost of HDPE Special complete in all respect. (For Arya Nagar Rohtak road) | 25 | Meter | - | - |
| 8 | National high way crossing by Trenchless (Miglani Colony): Boring, excavation by trenchless adopting HDD method (Horizontal Directional Drilling) below ground at all depth Including carriage etc. complete in all respect, construction of thrust pit and receiving pit of required size and depth and soil investigation making suitable arrangement for barricading of pits, traffic diversion, lights, refilling of pits in compacted layers of 150 mm including disposal of surplus material with all lift and lead upto 50 metre as per specification and the direction of the Engineer including provision of probe radar survey to check any underground obstruction before start of work. Manual Pipe jacking is not permitted for workmen safety reasons.
Providing and insertion of 500 mm i/d M.S. casing pipe 8 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 and also coating of inner and outer surface of casing pipe with high built epoxy paint as per R.D.S.O. specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion including cost and cartage of material to site of work complete in all respect as per srecification given in DNIT.
Providing, lowering, laying in trenches, aligning, fixing in position and jointing HDPE pipe PN-6 355 mm dia by Roller arrangement for smooth insertion and anchoring of pipe throughout the length with HDPE spacers at a distance of 2 meters apart to avoid contract of carrier pipe including cost of HDPE Special complete in all respect. (For Miglani Colony) | 25 | Meter | - | - |
| 9 | Trenchless Crossing (For R/M Shani Mandir Disposal): Boring, excavation by trenchless adopting HDD method (Horizontal Directional Drilling) below ground at all depth Including carriage etc. complete in all respect, construction of thrust pit and receiving pit of required size and depth and soil investigation making suitable arrangement for barricading of pits, traffic diversion, lights, refilling of pits in compacted layers of 150 mm including disposal of surplus material with all lift and lead upto 50 metre as per specification and the direction of the Engineer including provision of probe radar survey to check any underground obstruction before start of work. Manual Pipe jacking is not permitted for workmen safety reasons.
Providing and insertion of 200 mm i/d M.S. pipe 8 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 and also coating of inner and outer surface of casing pipe with high built epoxy paint as per R.D.S.O. specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion including cost and cartage of material to site of work complete in all respect as per srecification given in DNIT. (For Disposal Shani mandir) | 25 | Meter | - | - |
| 10 | NON CLOG SEWAGE PUMP: Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head below mentioned as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked.
`13000 LPM x 20 Mtr. Head | 1 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.96 MB
BOQ_601921.xls
BOQ • 0.28 MB
1F4BN0Z163775.pdf
Additional Documents • 19.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .