Loading…
Loading…
Tender Value
₹1 Cr
EMD Value
₹1 L
Closing Date
17 Apr 2026, 6:00 pmClosed
COMMISSIONER JUNAGADH MUNICIPAL CORPORATION
Annual Rate contract for Drilling different size of Bore and fitting casing pipes &Supplying with lowering different size of electrical pumping machinery with related fittings as per required of water works branch at Junagadh Municipal Corporation area
293400
E-Tender No.JuMC /WW /NIT No.14 Second Try
Open
Drilling Works
Junagadh
12 documents required · 12 mandatory
₹5,000
Commissioner,Municipal Corporation Junagadh
₹1 L
4 Apr 2026
4 Apr 2026
4 Apr 2026
17 Apr 2026
4 Apr 2026
Name Of Work:- Annual Rate for Drilling different size of Bore and fitting casing pipes & Supplying with lowering
different size of electrical pumping machionery with related fittings as per required of water works branch at
Junagadh Municipal Corporation area
Schedule-B (Excluding GST)
Sr. Item Discription Unit Rate
1 Drilling of 125 mm dia bore in over burden strata & lowering of casing & further drilling of RMT
bore in soft & hard rock with development of bore measuring the yield etc. comp.
2 Supplying & Jointing of casing pipe 140 mm / 160 mm dia size 6 kg / cm2 IS standard RMT
P.V.C. casing pipe of the site of work incl. Jointing materials etc. comp.
3 Supplying & Fitting of 140 mm / 160 mm dia size 6 kg / cm2 IS standard P.V.C. casing NO
4 Drilling of 165 mm dia bore in over burden strata & lowering of casing & further drilling of RMT
bore in soft & hard rock with development of bore measuring the yield etc. comp.
5 Supplying & Jointing of casing pipe 200 mm dia size 6 kg / cm2 IS standard P.V.C. RMT
casing pipe of the site of work incl. Jointing materials etc. comp.
6 Supplying & Fitting of 200 mm dia size 6 kg / cm2 IS standard P.V.C. casing cap plug. NO
7 Air Compressor
A Compressor test of tube well by air compressor of 400 CFM / 100 PSI capacity in all Hour
B Compressor test of tube well by air compressor of 600 CFM / 150 PSI capacity in all Hour
C Compressor test of tube well by air compressor of 900 CFM / 200 PSI capacity in all Hour
D Compressor test of tube well by air compressor of 1100 CFM / 300 PSI capacity in all Hour
8 Cleaning of bore hole by sand barrel system including removing foreign materials, sand, RMT
clay, pebbles etc. with necessory tools, plants and accessories.
9 Removing and dispoasal of excavated soil/borring cutting obtained after completion of job
125 mm/ 165 mm dia bore,including loading,transportation, and dumping at approved
location,complete(MR)
SECTION 4-6 / CABLE GLANDS.
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for
PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
(a) 2 to 4 core 2.5 / 4 Sq. mm Ea.
(b) 2 to 4 core 6 Sq. mm Ea.
(c) 2 to 4 core 10 Sq. mm Ea.
(d) 2 to 4 core 16 Sq. mm Ea.
(e) 2 to 4 core 25 Sq. mm Ea.
Providing and, fixing heavy duty flange type brass double compression type cable
gland with rubber ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables.
(a) 3 core 35/50 Sq. mm Ea.
(b) 3 core 70 Sq. mm Ea.
(c) 3 core 95 Sq. mm Ea.
(d) 3 core 120 Sq. mm Ea.
(e) 3 core 150 Sq. mm Ea.
(f) 3 core 185 Sq. mm Ea.
4-6- Providing and, fixing heavy duty flange type brass double compression type cable
gland with rubber ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables.
(A) 3 & 1/2 / 4 core 25 Sq. mm Ea.
(B) 3 & 1/2 core 35/50 Sq. mm Ea.
(C) 3 & 1/2 core 70 Sq. mm Ea.
(D) 3 & 1/2 core 95 Sq. mm Ea.
(E) 3 & 1/2 core 120 Sq. mm Ea.
(F) 3 & 1/2 core 150 Sq. mm Ea.
(G) 3 & 1/2 core 185 Sq. mm Ea.
(H) 3 & 1/2 core 240 Sq. mm Ea.
(I) 3 & 1/2 core 300 Sq. mm Ea.
(J) 3 & 1/2 core 400 Sq. mm Ea.
(K) 3 & 1/2 core 500 Sq. mm Ea.
SECTION 4-7 CABLE LUGS.
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of
4-7- following size evenly crimped with high pressure tool & connected to switchgear
1. terminals with brass/cadmium plated nut bolts in an approved manner.
4-7- Solder less crimping type Copper lugs conforming to IS suitable for cable of following
size evenly crimped with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
SECTION 8-13. WATER COOLERS
8-13- Providing and erecting water cooler having storage capacity 80Ltr. & cooling capacity 40 Nos.
1. Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop by
15˚ C within a hour, The water cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank surrounded by evaporating coil,
thermostats, relay etc. complete with necessary inlet & outlet connection. The body of
water cooler will be made from Stainless Steel. ◦
8-13- Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity Nos.
2. 150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop
by 15˚C within a hour, The water cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank surrounded by evaporating, coil,
thermostats, relay etc.complete with necessary inlet & outlet connection. The body of
water cooler will be made from Stainless Steel.
8-13- Providing & Erecting full SS Body (SS 304) Split type water cooler having storage Nos.
3. capacity 160 to 175 Ltr.(Tank SS 304) & Cooling capacity 150 ltr. Per hour @ an ambient
temp of 350 C.The outlet temp. of the water should drop by 150C within a hour,The water
cooler should be comprising of hermetically sealed Reciprocating compressor with
R134A, fan motor, Copper Condensing unit,water tank surrounded by evaporating coil,
thermostats, relay etc.complete with necessary copper tube & Insulation, M.S Chanel
Stand with Painting for water tank & M.S. Powder Coated Stand for Outdoor unit with
With DPELCB and 4 Way DB Box with accessory Three core Cord for connection.
8-13- Supplying and erecting approved make water filter having outer body of tough Nos.
4. polycarbonate with fitter cartridge having filter to trap micro elements with coupling
suitable for erection on pipe line.
8-13- Supplying and erecting water filter cum purifier with ultra violate technology. Nos.
5 (Aquaguard / waterdoc model or equivalent symphony/ crystal/videocon model)
8-13- Supplying & erecting 5 stage single reverse osmosis water purification system with M.S. Nos.
6 powder coated frame, prefilter housing with 'O' ring presediment filter GAC filter, carbon
filter suitable buster DC pump capacity 80 psi, mention with 40 psi inline type post
carbon filter auto low & high pressure switches with following size of storage tank & LPH
capacity & erected as directed with one year comprehensive maintenance guarantee.
[A] 10 Ltr / Hr with 7 Ltr Plastic Pressure Tank Nos.
[C] 50 Ltr / Hr with 250 psi 2 nos booster pump Nos.
8-13- Supplying & erecting reverse osmosis (RO) water purification system with M.S.
6 powder coated pedestal frame, prefilter housing carbon filter suitable buster DC pump,
auto low & high pressure switches with following size of LPH capacity & erected as
directed with one year comprehensive maintenance guarantee.
[D] 100 LPH with 3 phase Raw water pump of 500LPH @ 2.5kg/cm2 - (1N0 - Kirloskar Nos.
/CRI/Lubi), Dual media filter 10"x54" - (1 No), Micron cartridge filter 20" x 2.5" ( 1No),
High pressure pump 500LPH @ 10kg/cm2 - (1No - Shimge /CRI /Lubi), RO Membrane
housing with RO membrane of 40*40 - (1No), RO pressure tube 4" x 1E - ( 1No), 0 -
1200LPH Rotameter -(2 Nos), with Recovery Rate 50%.
[E] 200 LPH with 3 phase Raw water pump of 1000LPH @ 2.5kg/cm2 (1N0 - Nos.
Kirloskar/CRI/Lubi) , Dual media filter 10"x54" (1 No), Micron catridge filter 20" x 2.5" -
(1No), High pressure pump 1000LPH @ 10kg/cm2 - (1No - Shimge /CRI /Lubi) , RO
Membrane housing with RO membrane of 40*40 - ( 1 No),RO pressure tube 4" x 1E-
(1No), 0-1200LPH Rotameter-(2 Nos). Recovery Rate 50%.
[F] 500 LPH with 3 phase Raw water pump of 1000LPH @ 3.0 kg/cm2 (1No - Kirloskar Nos.
/CRI /Lubi), Dual media filter 13"x54" - (1No), Micron catridge filter 20" x 4.0"-1No, High
pressure pump 1000LPH @ 11kg/cm2 - (1No - lubi/ Shimge/ CRI), RO Membrane
housing with RO membrane of 40*40 - (2 Nos), RO pressure tube 4" x 2E -(1No), 0-
2400 LPH Rotameter ( 2Nos), , Dosing pump 0 -6 LPH - (1 No),. with 100 Ltr Dosing
tank - (1 No), with Recovery Rate 50%.
[G] 1000 LPH with 3 phase Raw water pump of 1700LPH @ 3.0 kg/cm2 (1No - Nos.
Kirloskar/CRI/Lubi), Dual media filter 13"x54" - 1 No, Micron catridge filter 20" x 4.0" -
(1No), High pressure pump 1000LPH @ 11kg/cm2 - (1No - Kirloskar/CRI/Lubi), RO
Membrane housing with RO membrane of 40*40 -(4 Nos), RO pressure tube 4" x 2E-
(2Nos), 0 - 2400LPH Rotameter ( 2 Nos). Dosing pump 0 -6 LPH (1 No) with 100 Ltr
Dosing tank - (1 No.), Recovery Rate 50%.
[H] 2000 LPH with 3 phase Raw water pump of 3400LPH @ 3.0 kg/cm2 (1No - Kirloskar Nos.
/CRI /Lubi), Dual media filter 18"x65" - 1 No., Micron catridge filter 20" x 4.0" - ( 2Nos),
High pressure pump 3400LPH @ 11kg/cm2 - (1No), Kirloskar/CRI/Lubi), RO
Membrane housing with RO membrane of 80*40 - (2 Nos), RO pressure tube 8" x 2E -
(1No), 0 - 3500LPH Rotameter - (2 Nos), Dosing pump 0 -6 LPH - (1 No). with 100 Ltr
Dosing tank - (1 No), Recovery Rate 50%.
CHEPTER - IX Pump
NOTE:The head and flow of pump is showing minimum values for getting best operating efficiency.
9-1- Supplying and erecting Direct - On - Line Starter with 18 A. rating contactor and with
1-A. 3.5 Amp. 18A range directly operated in totally insulated elegant enclosure for single
phase operation up to 3 HP as per IS 13947 complete erected on P.W. Block with
necessary connection.
9-1- Supplying and erecting Direct On-line Electronics Starter with 2-5/4-10/8-14/10-16 Ea
1-B Amp. Rating relay (variable current setting) directly operated in totally insulated elegant
enclosure and 18 Amp. Rating power relay with start - stop button for single phase
operation up to 3 HP as per complete erected on P.W. Block with following features.
Low voltage cut off below 140 V
High voltage cut off above 280 V
Overload protection
Indicating LEDs for motor on lv, hv & overload tripping. [Cat.II]
9-1- Supplying and erecting Direct-on-line, Starter with 15A.rating contractor and with 4-
2-A. 14A. range, directly operated thermal overload relay in sheet steel enclosure for 3phase
415V.50 c/s. A.C. motor up to 7.5 H.P.complete erected on P.W. Block with necessary
9-1- Supplying and erecting Direct on line starter with 30 Amp. (resistive @ 230v) power Ea
2-B relay and with 2 to 5/ 4 to 10 / 8 to 20 amp. Range C.T. Operated electronic overload
relay in engineering grade plastic enclosure for 3 ph 415v 50 HZ A.C. motor up to 7.5 HP
with high voltage protection (above 480 v) and under voltage protection (below 330 v)
current sensing single phasing protection. Reverse phasing protection, inverse current
characteristic overload protection with indication for On, OL, HV,LV SPP in a single unit
with feather touch start / stop push button, high temperature with standing Bakelite
terminals complete erected on P.W. Block with necessary connection. [Cat.II]
9-1- Supplying and erecting push button operated fully automatic Star-Delta starter with
3. Nos. of 15A.rating contactors and directly operated thermal overload relay having 10-
21A range and erected in sheet steel enclosure for 3 phase 415V. 50 c/s. A.C. motors
from 7.5 to 15H.P. complete erected on
(a) P.W. Block with necessary connection.
(b) Angle iron frame add to the above Ea.
9-1- Supplying and erecting push button operated fully automatic Star-Delta starter with
4. 3 Nos.of 32A. rating contactors and. 1 No. of directly operated thermal overload relay
having 20-32A range in sheet steel enclosure for 3 phase 415V. 50 c/s. A.C. motors up
to 35 H.P. complete erected on
(a)P.W.Blockwith necessary connection
(b) For erection on Angle iron frame add to the above. Ea.
9-1- Providing and erecting AC-3 duty 3 pole power contactor with 2 NO & 2 NC aux
5-1. contacts complete with 415V/220V operating coil suitable for (L&T, BCH,T.C., Siemens,
(a) for 25 / 32 A rating Ea.
(b) for 40 A rating Ea.
(c) for 60 / 70 A rating Ea.
(d) For 80 / 95 A Rating Ea.
(e) for 110 A rating Ea.
9-1- Providing and erecting AC-3 duty 3 pole power contactors spare kits (L & T, C&S,
5-2. BCH,T.C. Siemens, make).
(a) for 25 / 32 A rating Ea.
(b) for 40 A rating Ea.
(c) for 60 / 70 A rating Ea.
(d) For 80 / 95 A Rating Ea.
(e) for 110 A rating Ea.
9-1- Providing and erecting AC-3 duty 3 pole power contactor thermal over load relay ( L
5-3. & T BCH / Siemens, / C & S / Alstom make)
(a) For 4 - 15 Amp. rating Ea.
(b) For 25 Amp rating, Ea.
(c) For 32 Amp. rating Ea.
(d) For 40 Amp. Ea.
[e] For 48 to 70 Amp. Ea.
(f) For 80 to 110 Amp. Ea.
9-1- Providing and erecting AC-3 duty 4 pole A.C. Coil with 2 NO & 2 NC aux contacts
6 complete with 415V/220V operating coil suitable for (L&T, BCH,T.C., Siemens, C&S
(a) for 25 / 32 A rating Ea
(b) for 40 A rating Ea
(c) for 60 / 70 A rating Ea
(d) For 80 / 95 A Rating Ea
(e) for 110 A rating Ea
9-1- Pro. & erecting electronic overload relay with single phasing preventer [ (L&T,
7 Alstom, BCH,T.C., Siemens, C&S make).
[a] for 30 to 50 Amp. Ea
[B[ for 48 to 150 Amp. Ea
9-1- Providing and erecting operating coil for power contactors
(a) for 32A/40A Ea.
(b) for 70A/110A Ea.
9-1- Pro. & erecting motor protection circuit breaker with shock proof enclosure (IP 65)
9 erected as per direction for following motor HP 3 phase 440V A.C.
[A] up to 5 Hp 7 to 10 Amp. Ea
[B] up to 7.5 HP / 10 HP 12 to 18 Amp. Ea
[C] up to 15 HP 18 to 26 Amp. Ea
[D] up to 20 HP 24 to 36 Amp. Ea
9-2- Supplying and erecting approved make Analog type voltmeter moving iron with Ea.
1. square/ Round Dial, flush/pedestal mounting pattern for A.C.Voltage 0 to 500 Volt
range, erected on panel board with all connection, wiring etc.
9-2- Supplying and erecting approved make panel mounting type Digital Voltmeter having Ea.
2. 3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all
connection, wiring etc .with manufacturers calibration certificate.
9-2- Supplying and erecting approved make Analog type moving iron Ammeter direct Ea.
3. reading type 0-30A AC current, 500 V square /. Round dial, flush or projection type
complete erected with connection and wiring.
9-2- Supplying and erecting approved make panel mounting type Digital Ammeter having 3 Ea.
4. digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to
operate on 500 Volt AC , erected on existing panel board with all connection, wiring etc
.with manufacturers calibration certificate.
9-2- Supplying and erecting approved make Analog type moving iron C.T operated Ea.
5. Ammeter A C Current suitable slide in scale 0- 400 Amp. with 3 Nos. of Current
Transformer erected on panel board with connections.
9-2- Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase AC Supply Ea.
6. 500 V on existing panel board with necessary connections.
9-2- Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio Ea.
7. 15 VA burden erected in existing CRCA box duly secured with insulating materials
connected to the meter
9-2- Supplying & erecting approved make Power Factor Meter 150mm dia flush/projection Ea.
8. type/ balanced & unbalanced load to work with appropriately provided CT’s 100/5A to
400/5A ratio & other accessories complete erected in M.S. box & connected to the circuit
by means of PVC copper Core leads.
9-2- Supplying and erecting approved make suitable panel indicator lamps of LED type lamp, Ea.
9. lens cover, Bakelite holder complete erected with necessary connections.
9-2- Supplying & erecting directly operated single phasing preventer complete erected and Ea.
10. connected to supply up to 45 Amp. Range.
NOTE:The head and flow of pump is showing minimum values for getting best operating efficiency.
9-3- Supplying & erecting approved make self-priming domestic monoblock water pump
1. with 0.5 H.P. motor, suitable for operation on 230 volts 50 c/s. AC supply with metallic
flange, delivery and discharge of 32 LPM at 10 mtrs.head.
9-3- Supplying & erecting approved make self-priming domestic monoblock water pump
2. with 1 H.P motor, suitable for operation on 230 volts, 50c/s. AC supply with metallic
flange, and M.S. impeller delivery and following discharge
(a) 40 LPM at 24 mtrs. head suitable for 25mm dia. Delivery
(b) 100 LPM at 14 mtrs. head suitable for 25 mm dia. delivery
9-3- Supplying & erecting approved make self-priming domestic monoblock water pump
3 with 1.5 H.P motor, suitable for operation on 230 volts, 50c/s. AC supply with metallic
flange, and M.S. impeller delivery and following discharge 44 LPM at 32 Mtr head
suitable 25 mm dia delivery
9-4- Providing & erecting open well type horizontal mono block pump set with stainless
1. steel body having following specification
(A) 0.5 H.P. single phase open well motor pump set having discharge of 115 LPM @
mtr. head suitable for 32 mm dia. delivery pipe with control panel
(A-1) 0.75 H.P. single phase open well motor pump set having discharge of 170 LPM @
20 mtr. head suitable for 25 mm dia delivery pipe with control panel
(B) 1 H.P. single phase open well motor pump set suitable for 185 LPM discharge @
mtr. head, suitable for 32 mm dia. Delivery pipe with control panel.
(C) 1 HP Three phase open well motor pump set suitable for 190 LPM discharge @
mtr. head, suitable for 32mm dia. delivery pipe.
9-4- Providing & erecting open well horizontal mono block pump set with cast iron body,
2. complete for three phase submersible motor having
[A] For 1.5 HP 3 phase open well horizontal mono block pump set suitable for 190 LPM
@ 20 mtr head suitable for 40 mm dia delivery pipe
[B] For 2 HP 3 phase open well horizontal mono block pump set suitable for 200 LPM @
25 mtr head suitable for 50 mm dia delivery pipe
[C] For 3 HP 3 phase open well horizontal mono block pump set suitable for 85 LPM to
270 LPM @ 11 mtr to 33 mtr head suitable for 50/65 mm dia delivery pipe
[D] For 5 HP 3 phase open well horizontal mono block pump set suitable for 1350 LPM
to 310 LPM @ 10 to 42 Mtr head suitable for 50/65 mm dia delivery pipe
[E] For 7.5 HP 3 phase open well horizontal mono block pump set suitable for 1550 LPM
to 370 LPM @ 13.5 Mtr to 42 Mtr head suitable for 65/75 mm dia delivery pipe
[F] For 10 HP 3 phase open well horizontal mono block pump set suitable for 1725 LPM
to 940 LPM @ 15 to 36 MTR head suitable for 65/80 mm dia delivery pipe
[G] For 12.5 HP 3 phase open well horizontal mono block pump set suitable for
LPM to 950 LPM @ 24 to 40 MTR head suitable for 65/80 mm dia delivery pipe
[H] For 15 HP 3 phase open well horizontal mono block pump set suitable for 1600 LPM
to 1025 LPM @ 33 to 42 MTR head suitable for 65 /80 mm dia delivery pipe
[I] For 20 HP 3 phase open well horizontal mono block pump set suitable for 1750 LPM
to 1150 LPM @ 33 to 51 MTR head suitable for 65 /80 mm dia delivery pipe
[J] For 25 HP 3 phase open well horizontal mono block pump set suitable for 1850 LPM
to 1075 LPM @ 36 to 60 MTR head suitable for 65 /80 mm dia delivery pipe
[K] For 30 HP 3 phase open well horizontal mono block pump set suitable for 2450 LPM
to 1575 LPM @ 40 to 51 MTR head suitable for 80 / 100 mm dia delivery pipe
9-5- Supplying & erecting approved make Automatic liquid level controller 6A. with Ea.
1. sensor testing as per instruction of Engineer in charge on site complete with wiring
connection with existing wires , with copper conductor from pump to upper and lower
9-5- Supplying & erecting approved make motor control cubical panel (Direct - on - line)
2 made from 16 G. CRCA sheet duly epoxy powder painted inside and outside with hinged
doors and locking, arrangement consisting of suitable size of ON- OFF isolator (AC -
3/23duty) main fuses, single phasing preventer, indicating lamps for R- Y - B phases,
overload relay, Automatic water level controller, Ammeter, Voltmeter each with two way
selector switch incoming, wires duly socket crimped, main contactor & overload relay,
start - stop push buttons, to be erected on angle iron frame grouted on wall as directed.
The isolator, overload relay & contactors will be of L & T, Siemens or BCH make only.
(a) DOL up to 5.0 H.P. Ea.
(b) DOL for 7.5 H.P. Ea.
9-5- Supplying & erecting approved make motor control cubical panel [Star delta] made
3 from 16G CRCA sheet duly epoxy powder painted inside and outside with hinged doors
and locking with suitable size of ON - OFF isolator (AC 3 / 23 duty) main fuses. Digital
volt and current meter (in a single unit) with micro controller based control unit and
current sensing single phasing preventer electronic overload protection, over voltage
(Programmable) protection and under voltage (Programmable) protection, prod less dry
run protection programming facility for setting of all parameter like overload current, high
voltage limit, low voltage limit, dry run limit with digital indication on seven segment LED
display for any fault like over load, high voltage, low voltage, dry running single crimped,
electronic star delta timer, feather touch start / stop push buttons to be erected on angle
iron frame. Grouted on wall the contactors will be of L& T, Siemens, BCH make only)
(a) DOL up to 5.0 H.P. Ea
(b) DOL for 7.5 H.P. Ea
9-5- Supplying & erecting approved make 3 phase motor control cubical panel ( Star -
4 Delta) made from16 G. CRCA sheet duly painted with epoxy powder painted inside and
outside with hinged doors and locking arrangement, consisting of suitable size of ON-
OFF isolator (AC - 3/23 duty) main fuses, single phasing preventer cum water level.
Guard (Complete unit), Toggle switch to by pass Single phase preventer cum WLG,
indicating lamps for R- Y- B phases, over load relay, Automatic water level controller,
Ammeter & Voltmeter each with two way selector switch incoming wires duly socket
Crimped, Panel to be erected on angle iron frame grouted on wall as directed. Star
Delta & main contactor, overload relay, thermal / Electronic Star delta cutoff timer, start -
stop push buttons. The isolator overload relay & contactors of L& T, Siemens or Cuttler
Hamer make only. Panel to be erected on angle iron frame ground on wall.
9-5- Supplying & erecting approved make motor control cubical panel [Star delta] made
5 from 16G CRCA sheet duly epoxy powder painted inside and outside with hinged doors
and locking with suitable size of ON - OFF isolator (AC 3 / 23 duty) main fuses. Digital
volt and current meter (in a single unit) with micro controller based control unit and
current sensing single phasing preventer electronic overload protection, over voltage
(Programmable) protection and under voltage (Programmable) protection, prod less dry
run protection programming facility for setting of all parameter like overload current, high
voltage limit, low voltage limit, dry run limit with digital indication on seven segment LED
display for any fault like over load, high voltage, low voltage, dry running single crimped,
electronic star delta timer, feather touch start / stop push buttons to be erected on angle
iron frame. Grouted on wall the contactors will be of L& T, Siemens , BCH make only)
9-5- Supplying and erecting approved make3 phase motor control panel (ATS) made from
6 16 G. CRCA sheet duly painted with epoxy power paint inside and outside with hinged
doors and locking arrangement, consisting, of suitable switch of AC 23 duty with HRC
fuses (Cat.III), starting and running contactors, overload relay, Automatic water level
controller, Electronic timer with master timer CT operated Ammeter with selector switch,
Voltmeter with selector switch, phase indicating lamps, single phasing preventer , water
level guard, over load, start, run and stop push buttons, air cooled auto transformer with
60%, 70%, 80% tapping, Panel to be erected on angle iron frame grouted on wall as
directed., contactors relays, timer etc. shall be of L & T Siemens / Cutler Hammer make.
(a) Suitable for 25 H.P. Ea.
(b) Suitable for 30 H.P. Ea.
(c) Suitable for 35 H.P. Ea.
(d) Suitable for 40 H.P. Ea.
(e) Suitable for 50 H.P. Ea.
(f) Suitable for 60 H.P. Ea.
9-6- Supplying of single phase submersible pump set suitable for 100 mm size or more
1. dia bore well having motor capacity and discharge as under with necessary panel box
(a) Motor rating 1 HP (12 stage) pump having capacity of 50 LPM at 43 to 45 mtr head
suitable for 32 mm dia. delivery pipe
(b) Motor rating 1.5 HP (16 stage) pump having capacity of 50 LPM at 60 mtr head
suitable for 32 mm dia. delivery pipe
(c) Motor rating 2 HP (17 stage) pump having capacity of 106 LPM at 40 mtr head
suitable for 32 mm dia. delivery pipe
Note:- Add or less Rs. 450/- for Additional / Less Stage
9-6- Supplying submersible pump set suitable for bore of 100 mm. dia. or more having
2. three phase motor capacity not more than 3 H.P. of different range with following
(A) (20 stage) 170 to 185 LPM discharge at 57 to 48 mtrs. Respectively head suitable
for 50 mm dia. delivery pipe
(B) (15 stage) 130 LPM discharge at 50 mtrs. Respectively head suitable for 50 mm dia.
(C) (12 stage) 130 LPM discharge at 54 mtrs. Respectively head suitable for 50 mm dia.
Note:- Add or less Rs. 500/- for Additional / Less Stage
9-6- Supplying submersible pump set suitable for bore of 100 mm. dia. or more having
3. three phase motor capacity not more than 5 H.P. with following capacity ..
(a) (25 stage) 120 to 125 LPM discharge at 155 to 120 mtrs. head respectively suitable
for 50 mm dia. delivery pipe
(b) (16 stage) 140 to 180 LPM discharge at 96 to 69 mtrs. head respectively suitable for
50mm dia. delivery pipe
Note:- Add or less Rs. 550/- for Additional / Less Stage
9-6- Supplying submersible pump set suitable for bore of 150 mm. dia. or more having
4. three phase motor capacity not more than 5 H.P. with following capacity ..
(a) (8 stage) 240 to 200 LPM discharge at 70 to 78 mtrs. head respectively suitable for
50mm dia. delivery pipe
(b) ( 5 stage) 410 to 350 LPM discharge at 40 to 36 mtrs. head respectively suitable for
50mm dia. delivery pipe
Note:- Add or less Rs. 600/- for Additional / Less Stage
9-6- Supplying submersible pump set suitable for bore of 150 mm. dia. or more having
5. three phase motor capacity not more than 7.5 H.P. with following capacity ..
(a) (12 stage) 280 to 240 LPM discharge at 90 to 104 mtrs. head respectively suitable for
50mm dia. delivery pipe
(b) ( 8 stage) 390 to 350 LPM discharge at 62 to 70 mtrs. head respectively suitable for
50mm dia. delivery pipe
Note:- Add or less Rs. 650/- for Additional / Less Stage
9-6- Supplying submersible pump set suitable for bore of 150 mm dia or more having
6 phase motor capacity not less than 10 HP with following capacity.
[A] 10 stage 575 to 480 LPM discharge at 60 to 70 mtr head for 65 mm dia delivery pipe
[B] 20 stage 210 to 160 LPM discharge at 148 to 173 mtr head for 50 mm dia delivery
[C] 25 stage 160 to 100 LPM discharge at 185 to 220 mtr head for 50 mm dia delivery
Note:- Add or less for Item No 9-6-6 Rs. 900/- for Additional / Less Stage
9-6- Supplying submersible pump set for bore of 150 mm. dia. Or more having 3 phase
7-A. motor capacity not more than 12.5 H.With following capacity
(a)12 Stage, 390 to 350 L.P.M. discharge at the head about 95 to 107 mtrs. suitable
for 50 mm dia. Delivery pipe
9-6- (b)25 Stage, 210 to 140 L.P.M. discharge at the head about 185 to 229 mtrs.
7-B. suitable for 50 mm dia. Delivery pipe
Note:- Add or less Rs. 950/- for Additional / Less Stage
9-6- Supplying submersible pump set for bore of 150 mm. dia. Or, more having 3 phase
8. motor capacity not more than 15 H.P. and discharge capacity having
(a) (15 Stage) 480 to 330 L.P.M at the head 105 to 135 mtrs..suitable for 65 mm dia.
(b) (12 Stage) 360 to 410 L.P.M. at the head 84 to 108 mtrs suitable for 65 mm dia.
(c) (10 stage) 600 to 500 L.P.M. at the head 70 to 85 mtrs suitable for 65/50 mm dia.
(d) ( 8 stage) 695 to 492 L.P.M. at the head 48 to 73 mtrs suitable for 65/50 mm dia.
Note:- Add or less Rs. 1100/- for Additional / Less Stage
9-6- Supplying submersible pump set for bore of 150 mm. dia. Or more having 3 phase
9. motor capacity about 20 H.P and discharge capacity having
(a) (20 Stage) 370 to 350 LPM discharge at head in between 168 to 177 mtrs. suitable
for 50 mm dia. delivery pipe
(b) (14 Stage) 650 to 550 LPM discharge at head 84 to 112 mtrs suitable for 65 mm dia.
(c) ( 8 Stage) 1000 to 900 LPM discharge at head 59 to 64 mtrs suitable for 80 mm dia.
Note:- Add or less Rs. 1100/- for Additional / Less Stage
9-6- Supplying submersible pump set for bore of 200 mm. dia. or more having 3 phase
10. motor capacity about 25 H.P. and discharge capacity having
(a) (12 Stage) 472 to 330 L.P.M. discharge at the head 120 to 192 mtrs. suitable for
mm dia. delivery pipe
(b) (8 Stage) 1000 to 750 L.P.M. discharge at the head 87 to 115 mtrs. suitable for
mm dia. delivery pipe
(c) (6 Stage) 1000 to 800 L.P.M. discharge at the head 84 to 102 mtrs. suitable for
mm dia. delivery pipe
(d) ( 5 Stage) 1400 to 1200 L.P.M. discharge at the head 64 to 79 mtrs. suitable for
mm dia. delivery pipe
Note:- Add or less Rs. 2200/- for Additional / Less Stage
9-6- Supplying submersible pump set for bore of 200 mm. dia. or more having 3 phase
11. motor capacity about 30 H.P. and discharge capacity having
(a) ( 12 Stage) 650 to 440 L.P.M. discharge at the head 120 to 190 mtrs. suitable for
mm dia. delivery pipe.
(b) ( 10 Stage) 620 to 510 L.P.M. discharge at the head 130 to 160 mtrs. suitable for
mm dia. delivery pipe
(c) ( 8 Stage) 900 to 650 L.P.M.discharge at the head 104 to 152 mtrs. suitable for
mm dia. delivery pipe
(d) ( 5 Stage ) 1400 to 1150 L.P.M. discharge. at the head 70 to 85 mtrs. suitable for
mm dia. delivery pipe
9-6- Supplying submersible pump set for bore of 200 mm. dia. or more having 3 phase
12. motor capacity about 34/35 H.P discharge capacity having
(a) (12 Stage) 750 to 500 L.P.M. discharge at the head 172 to 204 mtrs. suitable for
mm dia. delivery pipe
(b) ( 6 Stage) 1600 to 1150 L.P.M. discharge at the head 72 to 102 mtrs. suitable for
mm dia. delivery pipe
(c) ( 5 Stage) 1500 to 1300 L.P.M. discharge at the head 75 to 85 mtrs. suitable for
mm dia. delivery pipe
9-6- Supplying submersible pump set for bore of 200 mm. dia. Or more having 3 phase
13. motor capacity about 40-45 H.P discharge capacity having
(a) (11 Stage) 930 to 780 L.P.M. discharge at. the head 154 to 182 mtrs. suitable for
mm dia. delivery pipe
(b) ( 9 Stage) 1270 to 1180 L.P.M. discharge at. the head 113 to 126 mtrs. suitable for
100 mm dia. delivery pipe
(c) (6 Stage) 1600 to 1300 L.P.M. discharge at the head 81 to 102 mtrs. suitable for
mm dia. delivery pipe
9-6- Supplying submersible pump set for bore of 200 mm. dia. or more having 3 phase
14. motor capacity about 50-55 H.P discharge capacity having
(a) ( 13 Stage) 100 to 400 L.P.M. discharge at the head 182 to 265 mtrs. suitable for
mm dia. Delivery pipe
(b) ( 10 Stage) 1400 to 1200 L.P.M. discharge at the head 117 to 128 mtrs. suitable for
100 mm dia. Delivery pipe having
(c) ( 8 Stage) 1400 to 1100 L.P.M. discharge at the head 113 to 138 mtrs. suitable for
100 mm dia. Delivery pipe having
9-6- Supplying submersible pump set for bore of 225 mm. dia. or more having 3 phase
15 motor capacity about 50-55 H.P discharge capacity having
(a) (6 Stage) 1800 to 1200 L.P.M. discharge at the head 86 to 114 mtrs. suitable for
mm dia. Delivery pipe having
9-6- Supplying submersible pump set for bore of 225 mm. dia. or more having 3 phase
16 motor capacity about 60 H.P discharge capacity having
(a) (10 Stage) 1400 to 1150 L.P.M. discharge at the head 141 to 164 mtrs. suitable for Ea.
100 mm dia. Delivery pipe [Cat.III]
(c) (7 Stage) 2200 to 1600 L.P.M. discharge at the head 81 to 124 mtrs. suitable for 125 Ea.
mm dia. Delivery pipe [Cat.III]
9-7- Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible
1. Submersible copper cable approved make of following Size.
(a) 3 Core x 1.5 Sq. mm. Mtr.
(b) 3 Core x 2.5 Sq. mm. Mtr.
(c) 3 Core x 4 Sq. mm Mtr.
(d) 3 Core x 6 Sq. mm. Mtr.
(e) 3 Core x 10 Sq. mm. Mtr.
(f) 3 Core x 16 Sq. mm. Mtr.
(g)3 Core x 25 Sq. mm Mtr.
(h) 2 Core x 1.5 Sq. mm Mtr.
(i) 2 Core x 2.5 Sq. mm Mtr.
9-7- Providing Water proof straight Joint in PVC insulated flat flexible copper cable by using
2. insulating material, water proofing material, & making the joint complete.
9-7- Supplying & erecting ISI Marked (Embossed) following size of “B” Class G.I . Pipe &
3. erecting as directed by Engineer-in-charge with necessary plumbing as desired.
(A) 25 mm dia Mtr.
(B) 32 mm dia Mtr.
(C) 40 mm dia Mtr.
(D) 50 mm dia Mtr.
(E) 65 mm dia Mtr.
(F) 80 mm dia. Mtr.
(G) 100 mm dia. Mtr.
9-7- Supplying ISI Marked (Embossed) following size of Heavy duty “C” Class G.I . Pipe
4. & erecting as directed by Engineer-in-charge with necessary plumbing as desired.
(A) 25 mm dia Mtr.
(B) 32 mm dia Mtr.
(C) 40 mm dia Mtr.
(D) 50 mm dia Mtr.
(E) 65 mm dia Mtr.
(F) 80 mm dia. Mtr.
(G) 100 mm dia. Mtr.
(H) 125 mm dia. Mtr.
9-7- Supplying and erecting with leak proof materials, M.S. Heavy duty ISI marked coupling
5. having threads of 8 TPI/11 TPI suitable for ‘C’ class pipe to take load of pump and pipe
assembly of following size andTPI :-
(A) 40mm( 1.5") dia. pipe 8 TPI Ea.
(B) 40mm( 1.5") dia. pipe 11 TPI Ea.
(C) 50 mm(2") dia. pipe 8 TPI Ea.
(D) 50mm (2") dia. pipe 11 TPI Ea.
(E) 65mm(2.1/2") dia. pipe 8 TPI Ea.
(F) 65mm(2.1/2") dia. pipe 11 TPI Ea.
(G) 80mm (3")dia pipe 8 TPI Ea.
(H) 80mm (3")dia. pipe 11 TPI Ea.
(I) 100mm(4") dia. pipe 8 TPI Ea.
(J) 100mm(4") dia. pipe 11 TPI Ea.
(K) 125mm (5") dia. pipe 8 TPI Ea.
(L) 125mm (5") dia. pipe 11’TPI Ea.
9-7- Add cost of leak proof complete welding surrounding pipe and coupling for use as
6. column pipe for following size
9-7- Cutting the heavy duty pipe and threading one end of pipe with 8 TPI / 11 TPI as
7. per requirement and including to and fro charges.
(A) 40mm ( 1.5") dia pipe Ea.
(B) 50mm (2") dia pipe Ea.
(C) 65mm(2.1/2") dia. Pipe Ea.
(D) 80mm (3") dia pipe Ea.
(E) 100mm (4") dia pipe Ea.
(F) 125mm (5") dia, pipe Ea.
9-7- Heavy duty clamp made from 4" x 1.5" iron strip suitable for column pipe 1.5" to
(A) 40 mm (1.5") dia pipe Ea.
(B) 50mm(2") dia pipe Ea.
(C) 65mm(2.1/2") dia. Pipe Ea.
(D) 80mm (3") dia pipe Ea.
(E) 100mm (4") dia pipe Ea.
9-7- Supplying & erecting G.l. bend for pipe connections suitable for
9-7- Supplying & erecting ISI Marked G.l. Elbow for pipe connections suitable for
9-7- Supplying & erecting ISI Marked G.l. Reducer Elbow for pipe connections suitable for
9-7- Supplying & erecting ISI Marked G.l. Reducer Socket for pipe connections suitable for
9-7- Supplying & erecting ISI Marked G.l. Union for pipe connections suitable for
9-7- Supplying & erecting Mild Steel heavy duty Flanges with rubber packing and
14. hardware materials for pipe connections suitable for
Supplying & erecting UPVC heavy duty Flanges with rubber packing and hardware
materials for pipe connections suitable for
9-7- Supplying and erecting ISI marked sluice valve at position with necessary material for
15. following size of pipe diameter.
9-7- Supplying, & erecting C.I. swing, check type non-return (Reflux) Valve -ISI marked
16. suitable for following size
(A) 50 mm dia. Ea.
(B) 65 mm dia. Ea.
(C) 80 mm dia. Ea.
(D) 100 mm dia. Ea.
(E) 125 mm dia. Ea.
9-7- Supplying of following size of STANDARD UPVC column pipe with coupler and wire
[A] 25 mm dia RMT.
[B] 32 mm dia RMT.
[C] 40 mm dia RMT.
[D] 50 mm dia RMT.
[E] 65 mm dia RMT.
[F] 80 mm dia RMT.
[G] 100 mm dia RMT.
9-7- Supplying of following size of HEAVY UPVC column pipe with coupler and wire lock
[A] 40 mm dia RMT.
[B] 50 mm dia RMT.
[C] 65 mm dia RMT.
[D] 80 mm dia RMT.
[E] 100 mm dia RMT.
9-7- Supply of following size of TOP & BOTTOM accessories i.e. Adaptor set (CI) long,
19 pump guard set, starter pipe Rubber ring for submersible pump & UPVC column
pipe as directed by Engineer - in - charge with necessary plumbing as desired.
[A] 25 mm dia Per Set
[B] 32 mm dia Per Set
[C] 40 mm dia Per Set
[D] 50 mm dia Per Set
[E] 65 mm dia Per Set
[F] 80 mm dia Per Set
[G] 100 mm dia Per Set
9-8- Supplying and erecting Fully Automatic hydro pneumatic booster system with cast ea.
1. iron housing Enclosure class IP44 minimum, with built in PTO motor protection and
stainless steel impeller pump, pump model GRUNDFOS CMB 5-46 series or
equivalent with 24 Liter hydro pneumatic pressurized tank capacity : 3.1 m3/hr,Rated
head :25 mtr motor rating : 1 H.P. includes pressure switches, Non Return Valve,
Pressure Gauge, 5 way Brass connector, with necessary Plumbing work of 25mm dia
suction and delivery pipe which includes all required size of pipes which includes all
required size of pipes, Joints valves, Bypass valve, labor all accessories required for
installation of pressure pump ( Foundation work and base stand cost included)
9-8- Supplying and erecting Fully Automatic hydro pneumatic booster system with cast ea.
2. iron housing Enclosure class IP44 minimum , with built in PTO motor protection and
stainless steel impeller pump, pump model GRUNDFOS CMB 5-46 series or equivalent
with 24 Liter hydro pneumatic pressurized tank capacity : 5 m3/hr,Rated head :30 mtr,
motor rating : 1.2 H.P. includes pressure switches, Non Return Valve, Pressure Gauge,
5 way Brass connector, with necessary Plumbing work which includes all required size of
pipes, Joints valves, Bypass valve, labor all accessories required for installation of
pressure pump ( Foundation work and base stand cost included)
9-8- Supplying and erecting Fully Automatic hydro pneumatic booster system with cast ea.
3. iron housing Enclosure class IP44 minimum , with built in PTO motor protection and
stainless steel impeller pump, pump modelGRUNDFOS CMB 5-46 series or equivalent
with 24 Liter hydro pneumatic pressurized tank capacity 8 m3/hr,Rated head :40 mtr,
motor rating : 1.5 H.P. includes pressure switches, Non Return Valve, Pressure Gauge,
5 way Brass connector, with necessary Plumbing work of 25mm dia suction and delivery
pipe which includes all required size of pipes, Joints valves, Bypass valve, labor all
accessories required for installation of pressure pump ( Foundation work and base stand
Chapter 11.2 / Diesel Generator Set
11-2- Hire charges for 240V A.C generating set following capacity with necessary fuel,
mains, switchgears & accessories complete running on load / no load as per
requirement. With transportation charges up to 30 kms..
[A] 1 KVA to 2 KVA
[B] 3 KVA to 10KVA
Hire charges for440V A.C generating set following capacity with necessary fuel, mains,
11-2- switchgears & accessories complete running on load / no load with acoustic sound proof
2 enclosure etc as per requirement. With transportation charges up to 30 kms.
[A] 3 KVA to 10KVA
[B] 11 KVA to 25 KVA ( excluding 25 KVA)
[C] 25 KVA to 40 KVA
[E] 75 KVA to 100 KVA
Hire charges for providing, erecting, and dismantling after use Flexible PVC insulated
11-2- multistrand multi core 1.1 kv grade lSl marked copper wires for sound system of
3 following size.
a).2 5 Sq.mm 3 core round l PVC sheathed Mtr
b).4.0 Sq mm 3 core round PVC sheathed Mtr
Miscellenous Items
Providing Water proof straight Joint in PVC insulated flat flexible copper cable by using
1 insulating material, water proofing material, & making the joint complete.
Supplying & erecting ISI Marked (Embossed) following size of “B” Class G.I . Pipe &
2 erecting as directed by Engineer-in-charge with necessary plumbing as desired.
(A) 25 mm dia Mtr.
(B) 32 mm dia Mtr.
(C) 40 mm dia Mtr.
(D) 50 mm dia Mtr.
(E) 65 mm dia Mtr.
(F) 80 mm dia. Mtr.
(G) 100 mm dia. Mtr.
Supplying ISI Marked (Embossed) following size of Heavy duty “C” Class G.I . Pipe
3 & erecting as directed by Engineer-in-charge with necessary plumbing as desired.
(A) 25 mm dia Mtr.
(B) 32 mm dia Mtr.
(C) 40 mm dia Mtr.
(D) 50 mm dia Mtr.
(E) 65 mm dia Mtr.
(F) 80 mm dia. Mtr.
(G) 100 mm dia. Mtr.
(H) 125 mm dia. Mtr.
Supplying and erecting with leak proof materials, M.S. Heavy duty ISI marked coupling
4 having threads of 8 TPI/11 TPI suitable for ‘C’ class pipe to take load of pump and pipe
assembly of following size andTPI :-
(A) 40mm( 1.5") dia. pipe 8 TPI Ea.
(B) 40mm( 1.5") dia. pipe 11 TPI Ea.
(C) 50 mm(2") dia. pipe 8 TPI Ea.
(D) 50mm (2") dia. pipe 11 TPI Ea.
(E) 65mm(2.1/2") dia. pipe 8 TPI Ea.
(F) 65mm(2.1/2") dia. pipe 11 TPI Ea.
(G) 80mm (3")dia pipe 8 TPI Ea.
(H) 80mm (3")dia. pipe 11 TPI Ea.
(I) 100mm(4") dia. pipe 8 TPI Ea.
(J) 100mm(4") dia. pipe 11 TPI Ea.
(K) 125mm (5") dia. pipe 8 TPI Ea.
(L) 125mm (5") dia. pipe 11’TPI Ea.
Add cost of leak proof complete welding surrounding pipe and coupling for use as
column pipe for following size
Cutting the heavy duty pipe and threading one end of pipe with 8 TPI / 11 TPI as
per requirement and including to and fro charges.
(A) 40mm ( 1.5") dia pipe Ea.
(B) 50mm (2") dia pipe Ea.
(C) 65mm(2.1/2") dia. Pipe Ea.
(D) 80mm (3") dia pipe Ea.
(E) 100mm (4") dia pipe Ea.
(F) 125mm (5") dia, pipe Ea.
Heavy duty clamp made from 4" x 1.5" iron strip suitable for column pipe 1.5" to
(A) 40 mm (1.5") dia pipe Ea.
(B) 50mm(2") dia pipe Ea.
(C) 65mm(2.1/2") dia. Pipe Ea.
(D) 80mm (3") dia pipe Ea.
(E) 100mm (4") dia pipe Ea.
8 Supplying & erecting G.l. bend for pipe connections suitable for
9 Supplying & erecting ISI Marked G.l. Elbow for pipe connections suitable for
Supplying & erecting ISI Marked G.l. Reducer Elbow for pipe connections suitable for
Supplying & erecting ISI Marked G.l. Reducer Socket for pipe connections suitable for
12 Supplying & erecting ISI Marked G.l. Union for pipe connections suitable for
Supplying & erecting Mild Steel heavy duty Flanges with rubber packing and
hardware materials for pipe connections suitable for
Supplying & erecting UPVC heavy duty Flanges with rubber packing and hardware
materials for pipe connections suitable for
Supplying and erecting ISI marked sluice valve at position with necessary material for
following size of pipe diameter.
Supplying, & erecting C.I. swing, check type non-return (Reflux) Valve -ISI marked
suitable for following size
(A) 50 mm dia. Ea.
(B) 65 mm dia. Ea.
(C) 80 mm dia. Ea.
(D) 100 mm dia. Ea.
(E) 125 mm dia. Ea.
Supplying of following size of STANDARD UPVC column pipe with coupler and wire
[A] 25 mm dia RMT.
[B] 32 mm dia RMT.
[C] 40 mm dia RMT.
[D] 50 mm dia RMT.
[E] 65 mm dia RMT.
[F] 80 mm dia RMT.
[G] 100 mm dia RMT.
Supplying of following size of HEAVY UPVC column pipe with coupler and wire lock
[A] 40 mm dia RMT.
[B] 50 mm dia RMT.
[C] 65 mm dia RMT.
[D] 80 mm dia RMT.
[E] 100 mm dia RMT.
Supply of following size of TOP & BOTTOM accessories i.e. Adaptor set (CI) long,
pump guard set, starter pipe Rubber ring for submersible pump & UPVC column
pipe as directed by Engineer - in - charge with necessary plumbing as desired.
[A] 25 mm dia Per Set
[B] 32 mm dia Per Set
[C] 40 mm dia Per Set
[D] 50 mm dia Per Set
[E] 65 mm dia Per Set
[F] 80 mm dia Per Set
[G] 100 mm dia Per Set
Providing and supplying in standard length ISI mark high density Polyethylene H.D.P.E.
Pipes suitable for potable water as per IS specification no. 4984/1995 including all local
20 and central taxes, transportation, freight charges,octroi, inspection charges, loading,
unloading, conveyance to the departmental stores etc. complete.
32 mm (RA) Mtr.
21 Supplying of water proof pach type Tap roll Mtr.
22 Supplying of Tafflon make 8mm/ 10mm/ 12mm black packing seal Kg.
23 Supplying of Tafflon make 8mm/10mm/12mm white packing seal Kg.
24 Supplying of ISI Mark PVC Tap roll. No.
25 Motor coupling. No.
26 Motor Oil Seal Set
27 Sand Guard No.
28 Motor Stud & Nut No.
29 Motor rotor blazing Job.
30 Connecting piece with couple key. Job.
31 Drain plug No.
32 Motor Base Complete Job.
33 Motor rotor through machining and varnishing etc. complete Job.
34 Motor cable guard mm
35 Replacement Stud nut No.
36 Pump NRV No.
37 Sand Guard No.
38 Pump L&Key bolt / lock No.
39 Pump shaft couple No.
40 Stud and nut SS No.
41 Pump opening servicing fitting etc. labour charge
Pump Set compleet per stage SS per
Pump Set compleet per stage GM per
46 V-4 Signle phase sub pums section Case No.
47 V-4 Signle phase sub pums section Bush No.
48 V-4 Signle phase sub pum Couple No.
49 V-4 Signle phase sub pum Bowl No.
50 V-4 Signle phase sub pum Bowl (Lubi) No.
51 V-4 Signle phase sub pum Bush No.
52 V-4 Signle phase sub pum bush lubi No.
53 V-4 Signle phase sub pum slive No.
54 V-4 Signle phase sub pump Support SS No.
V-4 Signle phase sub pump Pipe SS per
V-4 Signle phase sub pump Lath work Labour per
57 Sub Pump Connection Cable 2.5 mm Rmt.
58 Sub Pump Connection Cable 4 mm Rmt.
59 NVC Up to 2 HP Motor Startor No.
60 NVC Up to 7.5 HP Motor Startor No.
61 NVC Up to 20 HP Motor Startor No.
62 NVC Up to 30 HP Motor Startor No.
63 Relay Unit MK-1 No.
64 Relay Unit ML-2 No.
65 Relay Unit ML-3 No.
66 Relay Unit ML-4 No.
67 Contact Kit MK-1 No.
68 Contact Kit ML-2 No.
69 Moving Patti No.
70 Volte Meter No.
71 Ampier Meter No.
72 Volte Meter Gard No.
73 Ampier Meter Gard No.
74 Push Button Square No.
75 Starting Button No.
76 Moving Contect Bridge Up to 2 HP Motor Startor No.
77 Moving Contect Bridge Up to7.5 HP Motor Startor No.
78 Moving Contect Bridge Up to 20 HP Motor Startor No.
79 Moving Contect Bridge Up to 30 HP Motor Startor No.
80 Fix Contect Bridge Up to 2 HP Motor Startor No.
81 Fix Contect Bridge Up to7.5 HP Motor Startor No.
82 Fix Contect Bridge Up to 20 HP Motor Startor No.
83 Fix Contect Bridge Up to 30 HP Motor Startor No.
84 1-Phase Starting Capacitor No.
85 36 MFD capacitor No.
86 32 A Connector No.
87 63 A Connector No.
88 Verticle Turbine Pump At Anandpur Dam
a Pump Housing SS No.
c Pump main shaft 2620 X 47mm No.
d G Support Brass Bushing No.
e Pump Bottom long bush GM No.
f Section SS Sleeve short No.
j Section SS Sleeve long No.
h Section PU bushing No.
j Packing kits Set
k Pump glan housing Set
l Bearing No.6824 SKF No.
m Bearing No.29322E SKF No.
SKF Bearing 6319 C3 No.
n Gland Dori No.
q Nut Bolt (12 X 50) High Quality No.
s Couple Bush No.
t Bolt (22 X 75) High Quality No.
u Bolt (16 X 75) High Quality No.
v Nut, Bolt, Vicer (20 X 75) No.
x Gland Collar No.
y Shafting Machining (Through) No.
z Pump Housing Dismantling through Hydraulic No.
Couple Joto Flange pump motor set No.
Bush of Bolt No.
High Temperature Grease Per Kg
Glan Dori White 10mm Per Mtr
Glan Dori Black Vergin 10 mm Per Mtr
PVC box with door type Weatherproof IP 65 Suitable for Outdoor use Waterproof PVC
Enclosure with Cover Against Water Splash Outdoor IP65 as required size
89 S.S. Nipple for Hdpe pipe incl. fitting, labour,etc.
90 Chapdo suitable for
91 S.S. Pump jari
a Suitable For V4 pump / V6 Pump No.
92 T Bolt for submercible pump. No.
a Suitable For V4 pump /Suitable For V6 pump incl; double door No.
94 S.S. nipple 12 inch
95 Flange pair (HM8Mf) No.
96 V4 Pump repairing labour per stage No.
97 V6 pump repairing labour per stage No.
98 V4 pump ampular( rotter) per unit No.
99 V8 pump ampular (rotter) per unit No.
100 V8 Pump bowl per unit No.
101 Foot valve/ non return valve per unit No.
Lowering work of single submersible pump machionary in bore with loading different
102 size pipes,cable from water works store/ ware house & unloading at bore site of Ea.
junagadh municipal corporation area. (with cleaning site if necessary)
Lowering work of three submersible pump machionary in bore with loading different
103 size pipes,cable from water works store/ ware house & unloading at bore site of Ea.
junagadh municipal corporation area. (with cleaning site if necessary)
Lowering work of Three phase sub-pump in well with loading different size pipes,cable
104 from water works store/ ware house & unloading at bore site of junagadh municipal Ea.
corporation area. (with cleaning site if necessary)
105 Motor Pump CI type pin bush Couple joto
Constructing bore chamber with using cement concrete around bore of size (0.46 M x
0.46 M x 0.46 M ) with supplying and fitting 12mm thick iron cap size (0.46 M x 0.46 M )
with iron frame complete fitting above the chamber with suplying ring lock (Nos.1)
113 Providing and supplying Hand pump cylinder SS. Body
114 Providing and supplyingHand pump break bite saliya.
road cuplin No.
115 Providing and supplying general item for dipwell and handpump
1.25" vicer No.
2.5 " vicer No.
upper valve No.
lower valve No.
flvar upar na complet No.
cylinder nut No.
dabba danki pin shafteen No.
dabba danki set with cylinder No.
dipwell glan No.
chapla (dipwell rod pakadvana) No.
bering 6204 No.
bering 6205 No.
mibil oil 5 lit
dabba danki chain 1 no.
oil for dipwel 5 lit
handpump na hata 1 no.
handpump water tank 1 no.
foundation stand 1 no.
Constructing Handpump Auta with using cement concrete L.S. with labour work of
connection into nearest drainage pipe with required pipes,...etc complete.
Providing, Supply and fixing Rooftop Harvesting Module should be an efficient &
aesthetical solution to trap the sediments of rainwater coming from the rooftops. Its key
features should include maximum water recovery, large filter area and ease of
maintenance/installation with ergonomic considerations. It should be floor mounted M25
grade precast concrete module that has a circumscribing diameter of 390mm and a
height of 570mm. The filter spine should be made of PVC and 250 micron SS 316 mesh
with a filter surface area of 1100 cm2, having Filter spine should push fit assembly that
can be taken out easily for cleaning after removing precast concrete lid. RHM should
recover more than 99% of the water that enters the module. The Module should come
with a provision for first flush, a separate flush for the maintenance and an overflow.
Input should support 90/110 mm down take pipe with a provision of water entering into
the module from left or right side. Output should be 63 mm with a flexibility of its opening
in the left, right or bottom of the module. Filtration capacity of the module should be
m3 per hour and should be designed only for rooftop rainwater. Harvested rainwater can
be stored or diverted to a recharge well for groundwater recharging, including cost of
excavation, lowering laying, laying, refilling and commissioning, restoration, plumbing
from roof out late through RHM to hand pump with 90mm pvc pipe (4Kg / cm2) and
heavy pvc fiting.
(Note:- Length of pipeline which from rooftoop to borewell may be varies, Agnecy have to
complete all the work with required pipe and fitting materials, withing the street or area
4-3- Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables
(A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core) Mtr.
(A-1) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core) Mtr.
(B) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core) Mtr.
(C) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) Mtr.
(D) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) Mtr.
(E) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core) Mtr.
(F) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) Mtr.
(G) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core) Mtr.
(H) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core) Mtr.
(I) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core) Mtr.
(J) 3 1/2 core 400 Sq.mm ( 185 Sq. mm 1/2 core) Mtr.
(K) 3 1/2 core 500 Sq.mm ( 240 Sq. mm 1/2 core) Mtr.
(L) 3 1/2 core 630 sq. mm (300 sq.mm 1/2 core) Mtr.
SECTION 4-7 CABLE LUGS.
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of
4-7- following size evenly crimped with high pressure tool & connected to switchgear
1. terminals with brass/cadmium plated nut bolts in an approved manner.
4-7- Solder less crimping type Copper lugs conforming to IS suitable for cable of following
size evenly crimped with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
SECTION 3-1 SWITCHGEARS WITH REWIRABLE FUSES
3-1- providing and erecting Approved make Double Pole Plastic Switch and fuse 250V.,
1. 30A confirming to IS erected on Polished wooden block as directed.
3-1- Providing Approved make Double Pole Cast Iron Clad Switch & rewirable Fuse
2. / 250 V confirming to IS.
3-1- Erection & connection charges for 16A / 32 A DP as following
(a) on existing wooden block / A.I. frame Ea.
(b) on polished wooden block. Ea.
(c) on angle iron frame duly painted with Red Oxide Ea.
3-1- Providing Approved make Triple Pole Cast Iron Clad Switch & rewirable Fuse with
4. neutral link 415/500 V confirming to IS
3-1- Erection & connection Charges For 16A/32A TP as following
(a) on existing wooden block / A.I.frame Ea.
(b) on polished wooden block. Ea.
(c) on angle iron frame duly painted with Red Oxide Ea.
3-1- Providing Approved make Triple Pole Metal / Iron Clad Switch & Fuse with neutral
6. link 415/500 V confirming to IS
3-1- Erection & connection Charges for 63A/100A TP as following
(a) on existing wooden block / A.I.frame Ea.
(b) Erection on angle iron frame duly painted with Red Oxide Ea.
SECTION 3-2 / SWITCHGEARS WITH HRC FUSES.
3-2- Providing Approved make Triple Pole Metal Clad Switch Fuse Unit 415/500 V. with
1. HRC fuse of suitable load and neutral link confirming to IS.
3-2- Providing Approved make Triple Pole Metal Clad Switch Fuse Unit 415/500 V. with
2. HRC fuse of suitable load and neutral link confirming to IS
3-2- Providing Approved make Triple Pole metal clad switch fuse unit 415 / 500V. 400 A
3. with HRC fuse of suitable load and neutral link confirming to IS
3-2- Erection & connection charges for 32A/ 63 A / 100 A HRC TPN as following
(a)on existing wooden block / A.I.frame Ea.
(b)Erection on New angle iron frame duly painted with red oxide Ea.
3-2- Erection & connection Charges for 200A/ 250A/ 300 A /325 A/400 A HRC TPN as
(a)on existing wooden block / A.I. frame Ea.
(b)Erection on New angle iron frame duly painted with red oxide . Ea.
SECTION 3-3 / PANEL MOUNTING SWITCHGEARS
Providing and erecting Approved make panel mounting front fixing rotary switch
3-3- (CAM Switch) with face plate with double pair of contacts with two fix and a moving
contacts, operated by means of slide, rest on disk with grooves for sequential operation
rotated by switch handle, square shaft and knob for Two way with off
providing and erecting Approved make Three Phase & Neutral LT Heavy Duty Switch
3-3- Disconnector Fuse Unit Cubical type for panel mounting complete with operating
mechanism suitable to operate on 415V A.C. , 23A duty With HRC fuses of suitable load
confirming to IS. 13947 (Part I & III). of following capacities.
(c) 100Amp/125 Amp
Approved make Four Pole LT Heavy Duty Switch Disconnector Fuse Unit Cubical
3-3- type for panel mounting complete with operating mechanism suitable to operate on
3. 415V A.C. With HRC fuses of suitable load confirming to IS. 13947 (Part I & III). of
following capacities
3-3- Supplying & erecting following spare parts for panel mounting Switch Disconnector
3-3- Operational Handle Assembly Complete for
3-3- Operating Shaft (Extensible) for
3-3- Cable Terminal ( ‘Z" Type) Set of Two for
(i)200 / 250 Amps Ea.
(ii) 320 / 400 Amps Ea.
(iii) 630 / 800 Amps Ea.
3-3- Cable Terminal ( ‘Plain" Type)Set of Four for
(i) 32 / 63 Amps Ea.
(ii) 125 / 200 Amps Ea.
(iii) 250 / 320 Amps Ea.
3-3- HRC Fuse Contacts Set of six for
(i) 32 / 63 Amps Ea.
(ii) 125 Amps Ea.
(iv) 630 / 800 Amps Ea.
3-3- Moving Contact finger of Set of Six for 32 / 63 / 125 Amps
3-3- Moving Contact finger of Set of Eight for 200 / 250 / 320 / 400 / 630 / 800 Amps
3-3- Neutral Link for
SECTION 3-4 / MOULDED CASE CIRCUIT BREAKERS
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12 (The Enclosures
providing and erecting Approved make Four pole moulded case circuit breaker having
3-4- breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to
100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s.
with all internal connections & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Four pole moulded case circuit breaker having
3-4- breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with
2. Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all
internal connections & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Four pole moulded case circuit breaker
3-4- having breaking capacity ICU of 35 KA. at 415 V. having Normal current rating
200A.with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s.
with all internal connections & complete erected in existing 16 G.M.S.housing
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Four pole moulded case circuit breaker having
3-4- breaking capacity ICU of 35 KA. and above at 415 V . having normal current rating
250A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s.
with all internal connections & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Four pole moulded case circuit breaker having
3-4- breaking capacity ICU of 50 KA and above at 415 V having Normal current rating
400A. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s.
With all internal connections & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Four pole moulded case circuit breaker having
3-4- breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating up
to 630A. with variable thermal & magnetic release suitable to work on A.C.supply
c/s. with all internal connections & complete erected in existing 16 G.M.S. housing
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Four pole moulded case circuit breaker having
3-4- breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating
800A.with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s.
with all internal connections & complete erected in existing 16 G.M.S.housing.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Three pole moulded case circuit breaker
3-4- having breaking capacity ICU of 25 K.A. at 415 V having normal current rating up to
A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply
c/s. with all internal connections & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Three pole moulded case circuit breaker
3-4- having breaking capacity/strength ICU of 35 K.A. at 415 V. having normal current rating
125A.with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s.
with all internal connections & complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Three pole moulded case circuit breaker
3-4- having breaking capacity/strength ICU of 35 K.A. and above at 415 V. having Normal
current rating 200A.with variable Thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Three pole moulded case circuit breaker
3-4- having breaking capacity/strength ICU of 50 K.A. and above at 415V. having normal
current rating 250A. with variable thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Three pole moulded case circuit breaker
3-4- having breaking capacity/strength ICU of 50 K.A. and above at 415 V having Normal
current rating 400A.with variable Thermal & magnetic release suitable to work on
A.C.supply 50 c/s. With all internal connections & complete erected in existing 16 G.M.S.
ICS=100% of ICU only Cat III Ea.
providing and erecting Approved make Earth fault Relay suitable to mount with inter
3-4- connection suitable to following size of moulded case circuit breaker having CT ratio &
13. MCCB rating as following along with shunt trip 220V AC. with all internal connections &
complete erected in existing M.S.housing..
(1) 15 A -100 A , CT Ratio 1/100 Ea.
3-4- providing and erecting following additional parts for panel mounting MCCBs
(A)Extended operating rotary handle with pad lock with three position trip,off,on
suitable for 25A to 250 A panel mounting cat-III
(B)Extended operating rotary handle with pad lock with three position trip,off,on
suitable for 400A to 630 A panel mounting cat-III
SECTION 3-5 AIR CIRCUIT BREAKERS
providing and erecting Approved make standard manually operated fixed type
3-5- Pole Air circuit breaker. Having 50 kA breaking capacity ,Vsr=690 v, Ui=1kv ,impulse
1. voltage=12 kv with ICU=ICS=ICW (1 sec), with following type of relay and accessories.
(1) Equipped with DN-1 magneto thermal release, CTs & 6NO + 6NC auxiliary contacts
& secondary isolating contacts of following current ratings.
(a) 400Amp Cat III Ea.
(b) 630Amp Cat III Ea.
(c) 800Amp Cat III Ea.
(d) 1000Amp Cat III Ea.
(e) 1250Amp Cat III Ea.
(f) 1600Amp Cat III Ea.
(g) 2000 Amp Cat III Ea.
(2) with microprocessor Release with over load, short circuit, earth fault protection
(L.S.I.G.) and metering display in modular design with LED display and Test Trip button
facility, CTs and auxiliary contacts, of following current ratings
(a) 630Amp Cat III Ea.
(b) 800Amp Cat III Ea.
(c) 1000Amp Cat III Ea.
(d) 1250Amp Cat III Ea.
(e) 1600Amp Cat III Ea.
(f) 2000 Amp Cat III Ea.
(g) 2500 Amp Cat III Ea.
providing and erecting Approved make standard manually operated fixed type
3-5- Pole Air circuit breaker. Having following kA breaking capacity with ICU=ICS=ICW (1
2. sec),Vsr=690 v, Ui=1kv with following type of relay and accessories.
(1) Equipped with DN-1 magneto thermal release, CTs & 6NO + 6NC auxiliary
contacts & secondary isolating contacts of following current ratings
(A) 800Amp 50kA Cat III Ea.
(B) 1000Amp , 50 kA Cat III Ea.
(C) 1250Amp , 50 kA Cat III Ea.
(D) 1600Amp , 50 kA Cat III Ea.
(E) 2000 Amp , 50/55 kA Cat III Ea.
(F) 2500 Amp, 60 kA Cat III Ea.
(2) with microprocessor Release with over load, short circuit, earth fault protection
(L.S.I.G.) and metering display in modular design with LED display and Test Trip button
facility, CTs and auxiliary contacts, of following current ratings.
(A) 800Amp 50kA Cat III Ea.
(B) 1000Amp , 50 kA Cat III Ea.
(C) 1250Amp , 50 kA Cat III Ea.
(D) 1600Amp , 50 kA Cat III Ea.
(E) 2000 Amp , 50/55 kA Cat III Ea.
(F) 2500 Amp, 60 kA Cat III Ea.
(G) 3200 Amp, 60 kA Cat III Ea.
providing and erecting Approved make standard Draw out type 3 Pole Air circuit
3-5- breaker. Having following kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v,
3. Ui=1kv ,impulse voltage=12 kv with following type of relay and accessories.
(1) Manual Draw out type (MDO) with following type of relay system
(A) Equipped with DN-1 magneto thermal release, CTs & 6NO + 6NC auxiliary
contacts & secondary isolating contacts of following current ratings.
(i) 800Amp 50 kA Cat III Ea.
(ii) 1000Amp 50 kA Cat III Ea.
(iii) 1250Amp 50 kA Cat III Ea.
(iv) 1600Amp 50 kA Cat III Ea.
(v) 2000 Amp 50kA Cat III Ea.
(vi) 2500 Amp 60kA Cat III Ea.
(vii) 3200 Amp 75kA Cat III Ea.
(B) with microprocessor Release with over load, short circuit, earth fault
protection (L.S.I.G.) and metering display in modular design with LED display and
Test Trip button facility, CTs and auxiliary contacts, of following current ratings
(i) 800Amp 50 kA Cat III Ea.
(ii) 1000Amp 50 kA Cat III Ea.
(iii) 1250Amp 50 kA Cat III Ea.
(iv) 1600Amp 50 kA Cat III Ea.
(v) 2000 Amp 50kA Cat III Ea.
(vi) 2500 Amp 60kA Cat III Ea.
(vii) 3200 Amp 65kA Cat III Ea.
(viii) 4000 Amp 80kA Cat III Ea.
(2) Add Rs. 30500.00 in above said item for Electrically Draw out type (EDO) type in
place of manual draw out (MDO)
3-5- Approved make standard Draw out type 4 Pole Air circuit breaker. Having 50 kA
breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv
with following type of relay and accessories.
(1) Manual Draw out type (MDO) with following type of relay system
(A) Equipped with DN-1 magneto thermal release, CTs & 6NO + 6NC auxiliary
contacts & secondary isolating contacts of following current ratings.
(i) 800Amp 50 kA Cat III Ea.
(ii) 1000Amp 50 kA Cat III Ea.
(iii) 1250Amp 50 kA Cat III Ea.
(iv) 1600Amp 50 kA Cat III Ea.
(v) 2000 Amp 50kA Cat III Ea.
(vi) 2500 Amp 60kA Cat III Ea.
(vii) 3200 Amp 75kA Cat III Ea.
(B) with microprocessor Release with over load, short circuit, earth fault
protection and metering display in modular design with LED display and Test Trip
button facility, CTs and auxiliary contacts, of following current ratings.
(i) 800Amp 50 kA Cat III Ea.
(ii) 1000Amp 50 kA Cat III Ea.
(iii) 1250Amp 50 kA Cat III Ea.
(iv) 1600Amp 50 kA Cat III Ea.
(v) 2000 Amp 50kA Cat III Ea.
(vi) 2500 Amp 60kA Cat III Ea.
(vii) 3200 Amp 75kA Cat III Ea.
3-5- Providing & erecting Accessories For Air Circuit Breakers as follows:
(A) Six way Isolating Contact block Ea.
(B) Lockable Trip Push Button Type A,B,C,D Ea.
(C) Lockable Trip Push Button Kit L, M, LM, MN Ea.
(D) Locking of ACB in Isolated Position Ea.
(E) Locking of ACB in Any Position Ea.
(F) Racking Inter Lock Ea.
(G) Door Inter Lock Ea.
3-5- Providing & erecting additional parts for Air Circuit Breakers as follows:
(A) Auxiliary Contact Block for CN-CS 800 to 2500 & 2 NO + 2 NC Ea.
(B) Auxiliary Contact Block for CN-CS 800 to 2500 & 6 NO + 6 NC Ea.
(C) Arc Chutes for 800 / 1000 / 1250 / 1600 A ACBs Ea.
(D) Arc Chutes for 2000 / 2500 / 3200 A ACBs Ea.
(E) Shutter Accessories for 800 / 1000 / 1250/ 1600 A ACBs Ea.
(F) Shutter Accessories for 2000 / 2500 / 3200 A ACBs Ea.
(G) Shunt Release Type EA:24/48 V, 110V, 220V DC Ea.
(H) Shunt Release Type EA1 : 240V AC Ea.
(I) Under Voltage Release Type MV(2) : 240V AC, 415 V AC Ea.
(J) Earth Fault Release Type EF 1 (10%, 20% ) Ea.
(K) Earth Fault Release Type EF 2 (30%, 40%, 50% ) Ea.
(L) Thermal Magnetic Release Type DN1 Ea.
(M) CTs for 800 C / 1000 C with 400A / 640A and 800A taps for Fixed & Drawout
(N) CTs for 1250 C / 1600 C for Fixed & Drawout Type ACBs Ea.
(O) CTs for 2000 C & higher size With required taps for Fixed & Drawout Type
(P) Fixed Type Arcing Contacts Kit for 3 Pole ACB of 800A to 1600A Kit
(Q) Fixed Type Arcing Contacts ACB of 2000A to 2500A Ea.
(R) Moving Type Arcing Contacts Kit for 3 Pole ACB of 800A to 1600A Ea.
(S) Moving Type Arcing Contacts for 2000A to 2500A Ea.
SECTION 3-10 / MINIATURE CIRCUIT BREAKERS.
providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and
3-10- having breaking capacity 10 KA to be erected in existing box. confirming to IS
1.(A) 8828/1996 with ISI Mark
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to
3-10- operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in
1.(B) existing box. confirming to IS 8828/1996 with ISI Mark
Providing & erecting 240 V MCB double pole switch for motor & inductive load
(C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having
following capacity
(A) 6 to 32 Amp.
3-10- Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve)
having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following
(A) 6 to 32 Amp.
3-10- Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having
10KA breaking capacity & confirms to IS :8828 in existing box having following capacity
(a) 6 to 32 Amp.
3-10- Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve)
having 10KA breaking capacity & confirms to IS :8828 in existing box having following
(a) 6 to 32 Amp.
3-10- Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve)
having 10KA breaking capacity & confirms to IS :8828 in existing box having following
(a) 6 to 32 Amp.
Supplying & erecting 20 Amp 10 KA ‘C Curve’ single pole MCB with 20 Amp.
Plug socket, company fabricated powder coated sheet steel enclosure erected as
directed with connection.
[A] Metal Clad Socket with metal clad top
[B] 15 Amp. / 5 Amp. Five pin Universal Socket
Supplying & erecting approved make Electronics Starter and relay for air
conditioners in ABS plastic moulded housing. Company fabricated with bakelite
terminal for connection with silver coating bimetallic contact in switching device for o/p
with following features.
3-10- (1) Low Voltage Protection below 130 V
6-B (2) High Voltage protection above 270 V
(3) Overload protection for 2-5, 4-10, 8-14, 10-16, 14-22 Amp. (inverse time chara-)
(4) Indicating LEDs for AC on LV, HV, O/L, T/D
(5) With unique feature of 3 minute of time delay
3-10- Providing and erecting double pole Miniature isolator A.C. 22 duty confirms to IS
7. 13947-3 240V 40A in existing box.
3-10- Providing and erecting Three pole Miniature isolator A.C. 22 duty confirms to IS
8. 13947-3 in existing box.
(a) for 40 Amp.
(b) for 63 Amp.
(c) for 100 Amp.
3-10- Providing and erecting four pole Miniature isolator A.C. 22 duty confirms to IS 13947-
9. 3 in existing box.
(a) for 40 Amp.
(b) for 63 Amp.
(c) for 100 Amp.
3-10- Providing and erecting Two way Centre off Double pole MCB Change Over Switch
10. (IS 13947-3 / IEC 60947-3) in existing box.
(b) for 40 Amp.
3-10- Providing and erecting Two way Centre off Four pole MCB Change Over Switch (IS
11. 13947-3 / IEC 60947-3) in existing box.
SECTION 3-12 EARTH LEAKAGE CIRCUIT BREAKERS
providing and erecting Approved make ELCBs / RCCBs conforming to IS: 12640 and
3-12- having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having characteristic of quick action & tripping
with all advance feature & do not incorporate any electronic component. for following
Max. rating erected as directed
(ii) 40Amps. DP
(iii) 63 Amps. DP
providing and erecting Approved make ELCBs / RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
3-12- operation on 3 phase and neutral 415V,50Hz. having characteristic of quick action &
2. tripping with all advance feature & do not incorporate any electronic component for
following Max. rating erected as directed.
(ii) 40Amps. FP
(iii) 63 Amps. FP
(iv) 100 Amps. FP (100 mA Sensitivity)
Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working
on residual current device having 10 KA short circuit breaking capacity and
3-12- mAmp. Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob
3 facility trip free mechanism operating for rated leakage at nominal ten volt, complete
erected including all materials lugs screws etc. completed.
[a] 6A / 10A / 16A / 20A / 25A 2 pole single phase
[b] 32A / 40A, 2 pole Single Phase
[c] 63 A, 2 pole Single Phase
[d] 6A to 25 A, 4 Pole Three Phase
[e] 32A to 40 A, 4 Pole Three Phase
[f] 63A, 4 pole Three Phase
3.12. Supplying & fixing box for housing ELCB + MCB combination made of 18 SWG sheet
steel duly powder coated with gasket, dust & vermin proof bakelite shield two earthing
terminals for following type of RCCB, ELCB, ELCB + MCB
[a] For 2 pole Ea.
[b] For 4 Pole Ea.
SECTION 3-13 / DANGER NOTICE BOARDS.
3-13- Providing and erecting metallic vitrified danger notice board as per language
suggested by engineer incharge for MEDIUM VOLTAGE installation to be erected as per Ea.
3-13- Providing and erecting metallic vitrified danger notice board as per language
suggested by engineer incharge for HIGH VOLTAGE installation to be erected as per Ea.
3-13- Providing & erecting Medium Voltage Danger Notice Board sticker as per language
3 suggested by engineer incharge of standard size as per IS-2551
3-13- Providing & erecting High Voltage Danger Notice Board sticker as per language
4 suggested by engineer incharge of standard size-as per IS
SECTION 3-14 EARTHING
Follow IS code :3043 is the guideline for the earthing
3-14- Providing and erecting required size Aluminium strip for earthing of H.T. , OCB / ACB /
1 Transformer, LT panel board, Motors etc. using copper clamp.
3-14- Providing and erecting required size HOT deep Galvanised iron strip for earthing of
H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. Kg.
3-14- Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/
3 Transformer, LT panel board, Motors etc. using copper clamp.
3-14- Providing and erecting Annealed bare Copper wire 8 to 16 SWG.
3-14- Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia.
3-14- galvanised iron pipe with coupling and buch buried in specially prepared earth pit
6-A complete with necessary 8 SWG earth wire.
3-14- Providing and erecting Pipe type earthing with 40 mm dia 2.5 mtr long 'B' grade
G.I. pipe with necessary coupling buch buried in specially prepared earth pit & G.I. earth Ea.
wire of 8 SWG erected & connected as directed (For panel)
3-14- For using salt and charcoal / coke as required for pipe type earthing.
3-14- Add Extra for excavation in Semi hard rock (Murrum) by dry and wet blasting and
7 chiselling for pipe type earthing
3-14- Add Extra for excavation in Hard rock by dry and wet blasting and chiselling for pipe
8 type earthing.
Supplying & erecting earth pit of minimum bore dia.150mm size approved make
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made
of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value surrounded by highly
3-14- conductive compound with high charge dissipation suitable for following type of
9 applications with chamber and heavy duty cover.(approved make OEM has to submit
test certificate) & having back filling compound of (B) Inner chemical (CCM Compound)-
Resistivity:- 0.2 / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound
should be capable to retain moisture for long time Necessary test report must be
(a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr Ea.
Back filling compound - 1 Nos Bag of 15 Kg.
(b)For Electrical installation up to 11 KV in normal soil.
Length of Pipe : 2.00 mtrs Ea.
Back filling Compound :1 no. Bag of 25 Kg.
(c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing,
A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent
Earthing in normal soil. Ea.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make
Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-
3-14- 200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising,
connection terminal dia of 14 mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover.(approved make OEM has to submit
test certificate including value of earth resistane of installation.
[A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr Ea.
Back filling compound - 1 Nos. of Bag of 15 Kgs.
[B] For Electrical installation up to 11 KV located in other than normal soil i.e.
Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr
-Back filling Compound :1 no. Bag of 25 Kg.
[C] For Electrical Installation covering Transformer Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive Computer System(like Automation,
SCADA)i.e. independent Earthing located in other than normal soil i.e. Soft
Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
3-14- Providing one bag of 25 Kg. Additional Back Filling Compound (BFC) suitable for
11 safe earthing device.
Supplying & erecting funnel type earthing having earth plate of following size burred in
specifically prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with
alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with a wire mesh for
3-14- watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with
necessary length of double Galvanised Iron / copper earth wire No 6 SWG bolted with
lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to
the nearest switch gear with end socket as per direction & duly tested by earth tester
confirming to IS (As per drawing) with following specification
(A) With 30 x 30 x 0.35 cms: C.I. earth plate Ea.
(B) With 45 x 45 x 0.35 cms. C.I. earth plate Ea.
(C) with 60 x 60x 0.315 cms. Copper earth Plate Ea.
3-14- ADD Extra for excavation in Semi hard rock (Murrum) by dry and wet blasting and
13 chiselling for funnel type earthing of above
3-14- ADD Extra for excavation in Hard rock by dry and wet blasting and chiselling for funnel
14 type earthing of above .
providing and erecting Cast iron earth plate size 30 X 30 X 0.35 cms. buried in
3-14- specially prepared 2.5 Mtr. deep earth pit complete with necessary G.I. strip in G.I. pipe
15 2 Mtr. long with coupling and G.I. plug for earthing of switch gear, conduit run or power
providing and erecting Cast iron earth plate size 45 X 45 X 0.35 cms. buried in
3-14- specially prepared 2.5 Mtr. Deep earth Pit complete with necessary G.I. strip in G.I. pipe
16 2 Mtr. long with coupling and G.I. plug for earthing of switch gear, conduit run or power
A Earth Augar Machine 63 CC capacity No
Supplying and rotationally moulded HDPE storage tank with ISI mark of approved make
incl. taxes transporation octroi etc. complete.
Storage tank with ISI Mark (with outside black colour & inside lining)
6 1000 lit cap.
7 1500 lit cap.
8 2000 lit cap.
9 2500 lit cap.
10 3000 lit cap.
11 4000 lit cap.
12 5000 lit cap.
13 6000 lit cap.
14 7500 lit cap.
15 10000 lit cap.
As per Rate from R&B
Any extra required Electrical Items not included above Schedule-B
Electrical latest S.O.R.
Note:- G.S.T. will be paid as per used S.O.R. and its terms and condition for the G.S.T. If the
rate is including the G.S.T. then such tax will be not paid additionally, else such tax will be paid
GWSSB Electro-Mechanical
Tender Amount 1,00,00,000+GST
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender DIscription for bore and electric (4).pdf
SCH-B ARC Bore with electrical pumping machineries 2026-27.pdf
Download all tender documents and submit your bid