Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹28.8 L+₹1.0 L (3.71%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹29.2 L+₹1.4 L (5.01%)Rejected-Finance 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹29.5 L+₹1.7 L (6.27%)Rejected-Finance DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹29.8 L+₹2.0 L (7.18%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Aug 2020, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2020_MES_359875_1
GE MAINT EZHIMALA 8310
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(MAINT)EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE MAINT EZHIMALA
₹70,000
Yes
20 Aug 2020
10 Jul 2020
6 Aug 2020
10 Jul 2020
4 Aug 2020
23 Jul 2020
10 Jul 2020 - 20 Jul 2020
Amount
Taking down the unserviceable LT UG cable of size of 95 to 300 sqmm 3.5 core/04 core including removing electrical connection and keeping side serviceable cable include removing cable protection cover etc all as specified.
- ditto- all as per Item No 1 above but size up to 70 sqmm complete as specified.
Excavation in trenches not exceeding 1.5 metre in width and depth and getting out in hard and dense soil all as specified and as directed. Note ;- The excavation has to be done manually only.
Returning and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil
Removal of excavated soil to a distance not exceeding 50 metres and depositing at a level not exceeding 1.5 metre from starting point.
Supply and spreading crushed stone sand for cushioning of the UG cable in trenches all as specified and directed.
Supply and lay PCC un reinforced cable cover of size 250 mmx150mmx40mm , class LV type I flat for cable protection complete as specified and directed.
Relaying of PCC un reinforced LT cable cover of size 250 mmx150mmx40mm item obtained from ser no 1 complete as specified and directed by EIC
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs, glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size 300 sqmm 3.5 core complete as specified and directed Make;-Havells, RPG, Polycab.
-ditto- all as per Item No.9.00 above but size of 150 sqmm 3.5core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.9.00 above but size of 120 sqmm 3.5core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.9.00 above but size of 95 sqmm 3.5core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.9.00 above but size of 70 sqmm 3.5core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.9.00 above but size of 50 sqmm 3.5 core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.9.00 above but size of 35 sqmm 3.5 core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.9.00 above but size of 25 sqmm 3.5 core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.9.00 above but size of 16 sqmm 4.0 core complete as specified and directed Make Havells, RPG, Polycab.
supply and fix in replacement of Route indicator for marking of UG cable of any size with cast iron round plate not less than 100 mm dia suitably fitted on iron and embedded with PCC block of size 30 cm x 30 cm x 45 cm complete as specified.
M&L for Bus bar chamber outdoor type of size 60cmx 60cm x 45cm ,made out of 3mm thick MS sheet with 630 Amp rated copper busbar with necessary insulators mounted on 25x 25x 6mm thick angle iron legs fixed in pack foundation1:4:8 type D2 complete as specified and as directed.
M&L for Bus bar chamber outdoor type of size 45cmx 45cm x 30cm ,made out of 3mm thick MS sheet with 400 Amp rated copper busbar with necessary insulators mounted on 25x 25x 6mm thick angle iron legs fixed in pack foundation1:4:8 type D2 complete as specified and as directed.
Cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.5 metre and depth 0.7 metre all as directed and making good the road/hard using pre mix bituminous as required at site to match with the existing surface all as specified (NOTE: Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by EIC)
Supply and fix in replacement of GI tubing light grade 50 mm nominal dia in trench/road/pole for cable protection complete as specified and directed. Make Surya, Jindal
-ditto- all as per Item No. 22.00 above but size of 80 mm nominal dia
M & L for LT End termination joint kit 1100 volt indoor/out door type, size of 70 to 300 Sqmm 3.5/4 core all as specified and directed
M&L for Jointing LT straight through joint kit 1100 volt , size up to 120 Sqmm 3.5/4 core all as specified and directed
M&L for Jointing LT straight through joint kit 1100 volt , size of 150 to 400 Sqmm 3.5/4 core.
Supply and fix in replacement of MCB 63 Amps TPN 240/415 Volts, 'C' curve Make C&S/L&T /Legrand
Supply and fix in replacement of MCB 32 Amp TPN 240/415 Volts, 'C' curve Make : C&S/L&T /Legrand
Supply and fix in replacement of MCB 63 Amp Amps SPN 240/415 Volts, 'C' curve Make : C&S /L&T /Legrand
Supply and fix in replacement of MCB 40 Amp Amps SPN 240/415 Volts, 'C' curve Make : C&S/L&T /Legrand
Supply and fix in replacement of MCB 32 Amp Amps SPN 240/415 Volts, 'C' curve Make : C&S/L&T /Legrand
Supply and fix in replacement of MCB 06 to 32 Amp Amps SP 240/415 Volts, 'C' curve Make : C&S/L&T /Legrand
Supply and fix in replacement of MCCB up to100 Amp 16 KA /415volt rating/415volt TPN fixed thermal rating. Make:- L&T/ABB/ Indo Asian.
Supply and fix in replacement of MCCB 125 Amp 25 KA /415volt rating four pole fixed thermal rating. Make:- L&T/ABB/ Indo Asian.
Supply and fix in replacement of MCCB 250 Amp 25 KA/415volt rating four pole fixed thermal rating. Make:- L&T/ABB/ Indo Asian.
Supply and fix in replacement of MCCB 400Amp 36 KA/415volt rating four pole fixed thermal rating. Make:- L&T/ABB/ Indo Asian.
Supply and fix in replacement of MCCB 630Amp 36 KA rating TPN fixed thermal rating. Make:- L&T/ABB/ Indo Asian.
Supply and fix in replacement of MCCB up to 100 Amp 25 KA/415volt rating TP fixed thermal rating. Make:- L&T/ABB/ Indo Asian.
Supply and fix in replacement of MCCB 125 Amp 25 KA /415voltrating TP fixed thermal rating. Make:- L&T/ABB/ Indo Asian.
Supply and fix in replacement of MCCB 200 Amp 25 KA/415volt rating TP fixed thermal rating. Make:- L&T/ABB/ Indo Asian.
Supply and fix in replacement of MCCB 250 Amp 25 KA/415voltrating TP fixed thermal rating. Make:- L&T/ABB/ Indo Asian.
M&L for welding and fabrication works of out/indoor panel board of any size as per site requirement complete as specified by EIC
M&L greasing in hinges, cleaning and removing grass not exc 1 metre around of out/indoor panel of any size as site requirement complete as specified by EIC
Supply and fix in replacement of hinges, sliding door bolt of outdoor/indoor panel of any size as site requirement complete as specified by EIC
Supply and fix in replacement of Push bottom (on/off) (Red and green) complete as specified and as directed by Engr-in charge.
Supply and fix in replacement of toggle switch as site requirement complete as specified and directed by EIC
Supply and fix in replacement of Volt meter/Amp meter Volt complete as specified and directed by EIC Make AE/L&T
Supply and fix in replacement of surface mounted device LED indicator(Red, green, yellow), low power consumption, surge and low voltage glow protection as on site requirement
Supply and fix in replacement of Multifunction meter VAF+PF, 3 phase 5A rating flush mounting complete as specified and directed by EICL&T/HPL/Ducati/ABB
General Engineering and Constructions
ROTECH ENGINEERS AND BUILDERS
KDR CONSTRUCTION
G P ENGINEERS
Gates Infra Construction Co
pk janardhanan
ANAND REFRIGERATION
devan enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .