| 1 | L1₹44.8 LAccepted-AOC LG 4 LANDMARK ARCADE BADSHAH NAGAR LUCKNOW UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | L1 | Accepted-AOC Amount after negotiation, L1 Bidder | |
| 2 | L2₹45.8 L+₹5,150.75 (0.11%)Rejected-AOC | L2 | Rejected-AOC L2 bidder | |
| 3 | L3₹45.9 L+₹17,386.05 (0.38%)Rejected-AOC BLOCK S HOUSE 75 MOHAN GARDEN WEST DELHI DELHI 110059 | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC L3 bidder |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
7 Jun 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC I, Lucknow
Pareshan Bhawan, Vibhuti Khand, Lucknow
Providing and fixing of Anti kite Bird net for 132 KV Substations under ETD I, Lucknow
2021_UPTCL_572555_1
E-tender 114/2020-21
Open Tender
Electrical Works
Piece-work
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹46,000
8 Jul 2021
18 Mar 2021
8 Jun 2021
18 Mar 2021
7 Jun 2021
18 Mar 2021
180 days
Amount
A) 132 KV S/S TRT :
Net/Mesh portion
Providing UV Stabilized high density Poly Ethelene made anti Kite flying/anti bird net of following specifications : DUAL LAYER 5 MM Braided with CONTAINMENT SAFETY NET • First Layer : Machine Knotted 5 mm braided with 100 mm X 100 mm Mesh Size • Second Layer : Strong containment net 5*3 Ply Fishnet • Border Rope : 12 mm Maxima IS : 5175:1992 • Tie cord : 12 mm Maxima 1.5 Mtr long at 4 corners and 1.5 Mtr long Tie Cord at every 2.5 mtr interval distance. Make : (Garware/Equivalent Standard Make).
Providing 24 mm dia UV Resistant PP frame rope conforming IS:14929:2001 as per technical specification enclosed.
Erection of a PP frame rope for providing adequate support to Item 1 (a) with the help of tensioners etc. on gantry/STPs as per technical specifications, enclosed drawings and instructions of supervising engineer.
Installation of Item 1(a) on top of PP frame with the help tensioners etc on Gantry /STPs as per technical specifications, enclosed drawings and instructions of supervising engineer.
Steel Supports
Providing of Steel Tubular Pole of 11 Meter as per IS 410 SP-55
Erection and Grouting of Steel Tubular Pole of 11 Meter (as per IS 410 SP-55) with Base Pate . The work includes : a) Excavation of foundation pit in mix soil/normal soil, soft & hard rack and its back filling and levelling etc. The size of the pit will be 600x900 mm and having a depth of 1.8 meter. Erection of supports by providing stone pad, fixing of Stainless Steel U-bolt/Clamp of required size including any fabrication, if required. b) Grouting of above supports with cement, concrete (CC will be of cement coarse sand & brick ballast) in ratio1:4:8 & 1/6 of full length (1.8 m) of the support, plinthing 300 mm above ground level in CC of 1:4:8 & plastering of the same with 12 mm thick plaster of cement & sand in 1:4 ratio. (c) Earthing of supports with Earth Electrode 2.5 mtr. length including excavation of pit and driving M.S. Rod upto proper depth and connecting the earth electrode with the help of 8 SWG G.I. Wire and earthing lugs. . The work shall be done as per the technical specifications and satisfaction of the Supervising Engineer (All materials including MS Earthing rods, G.I. wire, U-bolt/Clamp etc. shall be provided by the contractor)
Providing of Steel Tubular Pole of 13 Meter as per IS 410 SP-70
Erection and Grouting of Steel Tubular Pole of 13 Meter (as per IS 410 SP-70) with Base Pate . The work includes : a) Excavation of foundation pit in mix soil/normal soil, soft & hard rack and its back filling and levelling etc. The size of the pit will be 600x900 mm and having a depth of 2.0 meter. Erection of supports by providing stone pad, fixing of Stainless Steel U-bolt/Clamp of required size including any fabrication, if required. b) Grouting of above supports with cement, concrete (CC will be of cement coarse sand & brick ballast) in ratio1:4:8 & 1/6 of full length (1.8 m) of the support, plinthing 300 mm above ground level in CC of 1:4:8 & plastering of the same with 12 mm thick plaster of cement & sand in 1:4 ratio. (c) Earthing of supports with Earth Electrode 2.5 mtr. length including excavation of pit and driving M.S. Rod upto proper depth and connecting the earth electrode with the help of 8 SWG G.I. Wire and earthing lugs. . The work shall be done as per the technical specifications and satisfaction of the Supervising Engineer (All materials including MS Earthing rods, G.I. wire, U-bolt/Clamp etc. shall be provided by the contractor)
Making 03 No. Strips of 50 mm width at the height of 450 mm from the Plinth with P.O. Red colur in bottom & top and with White Colour in the middle on each M.S. Round Ple and making 150 mm dia circle and writing the Serial Number of Pole in the circle.
Stays
Providing of Stay Set 16X1800 mm for support to STPs
Erection of stay (with set of 16x1800mm Rod duly Painted with Red Oxide,Anchor Plate , Thumble Turn Buckle and stay Insulator Etc) by Grouting (including excavation of pits & laying of cc ratio 1:3:6 with Cement, Coarse Sand and 40 mm Brick Ballast mixture as per technical specifications and satisfaction of the Supervising Engineer) and binding with STPs with the help of 7/10 GI Wire/Earth wire and tightening with suitable clamp. (Earth wire/GI Wireand clamps to be provided by the contractor).
B) 132 KV S/S Mehtab Bagh :
Net/Mesh portion
Providing UV Stabilized high density Poly Ethelene made anti Kite flying/anti bird net of following specifications : DUAL LAYER 5 MM Braided with CONTAINMENT SAFETY NET • First Layer : Machine Knotted 5 mm braided with 100 mm X 100 mm Mesh Size • Second Layer : Strong containment net 5*3 Ply Fishnet • Border Rope : 12 mm Maxima IS : 5175:1992 • Tie cord : 12 mm Maxima 1.5 Mtr long at 4 corners and 1.5 Mtr long Tie Cord at every 2.5 mtr interval distance. Make : (Garware/Equivalent Standard Make).
Providing 24 mm dia UV Resistant PP frame rope conforming IS:14929:2001 as per technical specification enclosed.
Erection of a PP frame rope for providing adequate support to Item 1 (a) with the help of tensioners etc. on gantry/STPs as per technical specifications, enclosed drawings and instructions of supervising engineer.
Installation of anti Kite flying/anti bird net on top of PP frame with the help tensioners etc on Gantry /STPs as per technical specifications, enclosed drawings and instructions of supervising engineer.
Supply & fixingof wall roof type service bracket of 50 mm dia 4 Meter long fabricated from class "B" G.I. pipe complete with two bends, sockets, wall clamps. 7/3.15 mm G.I. stay wire, stay insulatorsetc. complete in allrespect.
Steel Supports
Supply and fixing of 7 meter GI Octagonal Pole of standard make (Top dia 70mm, Bottom Dia 130 mm and base plate 12 mm thickness) having 3 mm thickness with arm bracket ( 1 meter length) on RCC Foundation including the cost of foundation, foundation bolt, excavation and backfilling and required T&P)
Making 03 No. Strips of 50 mm width at the height of 450 mm from the Plinth with P.O. Red colur in bottom & top and with White Colour in the middle on each M.S. Round Ple and making 150 mm dia circle and writing the Serial Number of Pole in the circle.
Stays
Providing of Stay Set 16X1800 mm for support to STPs
Erection of stay (with set of 16x1800mm Rod duly Painted with Red Oxide,Anchor Plate , Thumble Turn Buckle and stay Insulator Etc) by Grouting (including excavation of pits & laying of cc ratio 1:3:6 with Cement, Coarse Sand and 40 mm Brick Ballast mixture as per technical specifications and satisfaction of the Supervising Engineer) and binding with STPs with the help of 7/10 GI Wire/Earth wire and tightening with suitable clamp. (Earth wire/GI Wireand clamps to be provided by the contractor).
C) 132 KV S/S HANUMAN SETU :
Net/Mesh portion
Providing UV Stabilized high density Poly Ethelene made anti Kite flying/anti bird net of following specifications : DUAL LAYER 5 MM Braided with CONTAINMENT SAFETY NET • First Layer : Machine Knotted 5 mm braided with 100 mm X 100 mm Mesh Size • Second Layer : Strong containment net 5*3 Ply Fishnet • Border Rope : 12 mm Maxima IS : 5175:1992 • Tie cord : 12 mm Maxima 1.5 Mtr long at 4 corners and 1.5 Mtr long Tie Cord at every 2.5 mtr interval distance. Make : (Garware/Equivalent Standard Make).
Providing 24 mm dia UV Resistant PP frame rope conforming IS:14929:2001 as per technical specification enclosed.
Erection of a PP frame rope for providing adequate support to Item 1 (a) with the help of tensioners etc. on gantry/STPs as per technical specifications, enclosed drawings and instructions of supervising engineer.
Installation of anti Kite flying/anti bird net on top of PP frame with the help tensioners etc on Gantry /STPs as per technical specifications, enclosed drawings and instructions of supervising engineer. (Wall mounted Tension clamps shall be provided by contractor if instructed by Supervising Engineer, wherever necessary but limited to 10 in nos)
Supply & fixingof wall roof type service bracket of 50 mm dia 4 Meter long fabricated from class "B" G.I. pipe complete with two bends, sockets, wall clamps. 7/3.15 mm G.I. stay wire, stay insulatorsetc. complete in allrespect.
Steel Supports
Supply and fixing of 7 meter GI Octagonal Pole of standard make (Top dia 70mm, Bottom Dia 130 mm and base plate 12 mm thickness) having 3 mm thickness with arm bracket ( 1 meter length) on RCC Foundation including the cost of foundation, foundation bolt, excavation and backfilling and required T&P)
Providing of Steel Tubular Pole of 13 Meter as per IS 410 SP-70
Erection and Grouting of Steel Tubular Pole of 13 Meter (as per IS 410 SP-70) with Base Pate . The work includes : a) Excavation of foundation pit in mix soil/normal soil, soft & hard rack and its back filling and levelling etc. The size of the pit will be 600x900 mm and having a depth of 2.0 meter. Erection of supports by providing stone pad, fixing of Stainless Steel U-bolt/Clamp of required size including any fabrication, if required. b) Grouting of above supports with cement, concrete (CC will be of cement coarse sand & brick ballast) in ratio1:4:8 & 1/6 of full length (1.8 m) of the support, plinthing 300 mm above ground level in CC of 1:4:8 & plastering of the same with 12 mm thick plaster of cement & sand in 1:4 ratio. (c) Earthing of supports with Earth Electrode 2.5 mtr. length including excavation of pit and driving M.S. Rod upto proper depth and connecting the earth electrode with the help of 8 SWG G.I. Wire and earthing lugs. . The work shall be done as per the technical specifications and satisfaction of the Supervising Engineer (All materials including MS Earthing rods, G.I. wire, U-bolt/Clamp etc. shall be provided by the contractor)
Making 03 No. Strips of 50 mm width at the height of 450 mm from the Plinth with P.O. Red colur in bottom & top and with White Colour in the middle on each M.S. Round Ple and making 150 mm dia circle and writing the Serial Number of Pole in the circle.
Stays
Providing of Stay Set 16X1800 mm for support to STPs
Erection of stay (with set of 16x1800mm Rod duly Painted with Red Oxide,Anchor Plate , Thumble Turn Buckle and stay Insulator Etc) by Grouting (including excavation of pits & laying of cc ratio 1:3:6 with Cement, Coarse Sand and 40 mm Brick Ballast mixture as per technical specifications and satisfaction of the Supervising Engineer) and binding with STPs with the help of 7/10 GI Wire/Earth wire and tightening with suitable clamp. (Earth wire/GI Wireand clamps to be provided by the contractor).
DPR CONSTRUCTION
M/S KSHITIJ ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .