Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹40.9 L+₹13.6 L (49.7%)Rejected-Finance | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹42.9 L+₹15.6 L (57.2%)Rejected-Finance | L3 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
MAINTENANCE / REPAIR OF DG INSTALLATION, REPLACEMENT OF PARTS WITH ALLIED WORKS AND REPAIR / REPLACEMENT OF LT EXTERNAL ELECTRIFICATION WITH CONNECTED WORKS AT R AND O FLT UNDER GE (WEST) BAREILLY.
2024_MES_665916_1
8202/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST BAREILLY
₹99,000
Yes
24 Oct 2024
13 Jul 2024
16 Sept 2024
13 Jul 2024
12 Sept 2024
28 Jul 2024
Amount
DG Set
General servicing of DG Set including B check ,cleaning of machine,replacement of oil filter,fuel filter and air filter ) cleaning of fuel tank, checking of oil level,checking of tension in fan belts,checking and repair of leakages in hose pipe, proper adjustment of tappet, checking of Governor control assembly, radiator,complete all as per manufactaures recommendations for following capacity and make of DG sets. Note: (i) Rate of all filters deemed to be included in the quoted rate of general servicing of DG Sets. (ii) Cost of Engine Oil to be included in quoted rate.
125 KVA Cummins/ Kirloskar DG Set
500/600 KVA Jackson Kirloskar DG Set
250 KVA any make
82.5/63/62.5 KVA Kirloskar/Ruston/Ashoka Leyland DG set
20/40 KVA DG set Make : Kirloskar
15/10 KVA DG set Make : Kirloskar
Dismantling / stripping diesel engine of DG Det of 63/40 KVA rating capacity after separating alternator from common base frame setting a side for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detained inspection complete all as specified and directed. Note :- Spares shall be measurd & paid separately under relevent items of BOQ.
Supply and fixing of the following spares for DG Set 63/40 KVA Make- Kirloska/Ashoka required to be replaced under relevant item here in before complete all as specified and directed :-
(a) Piston std size Cat Part No. as existing.
(b) Piston Ring Cat Part No. as existing.
(c) Piston Pin Cat Part No. as existing.
(d) Cylinder liner (Sleeve) Cat Part No. as existing.
(e) Exhaust valve Cat Part No. as existing.
(f) Inlet valve -Cat Part No. as existing.
(g) Packing kit Cat Part No. as existing.
(h) Oil Seal Cat Part No. as existing.
(j) Oil Pressure guage Cat Part No. as existing.
(k) Kit "O" Ring Cat Part No. as existing.
(l) Fuel flexible pipe Cat Part No. as existing.
(m) Oil Filter with gasket Cat Part No. as existing.
(n) Diesel filter with gasket Cat Part No. as existing.
(o) Connecting Rod bush Cat Part No. as existing.
(p) Thrust washer Cat Part No. as existing.
(q) Valve guide inlet and outlet seat Cat Part No as existing
(r ) Cylinder Head Gasket Cat Part No as existing
(s) Packing kit.Cat Part No as existing
(s) Fuel injection pipes.Cat Part No as existing
(t) Air Filter Cat Part No as existing
(u) Primary element
(v) Stop Solenoid
Dismantling / stripping diesel engine of DG Det of 15/20 KVA rating capacity after separating alternator from common base frame setting a side for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detained inspection complete all as specified and directed. Note :- Spares shall be measured & paid seperately under relevent items of Sch 'A'.
Supply and fixing of spares for DG Set 15/20 KVA Make Kirlosker, Cummins required to be replaced under relevant item here in before complete all as specified and directed .
(a) Piston std size Cat Part No. as existing.
(b) Piston Ring Cat Part No as existing.
(c) Piston Pin as existing.
(d) Cylinder liner 22001-40847
(e) Exhaust valve Cat Part No as existing
(f) Inlet valve Cat Part No as existing
(g) Packing kit (Gasket) Cat Part No as existing
(h) Oil Seal Cat Part No as existing
(j) Oil Pressure guage (Precell) Cat Part No as existing
(k) Kit "O" Ring 7B -Cat Part No as existing
(l) Fuel flexible pipe Cat Part No as existing
(m) Oil Filter B-Cat Part No as existing
(n) Diesel filter Cat Part No as existing
(o) Connecting Rod assembly make kirloskar cat part no 4200910000
(p) Thrust washer YD -Cat Part No as existing
(q) Valve guide inlet and outlet seat Cat Part No as existing
(r) Cylinder Head Gasket / packet kit.
(s) Fuel injection pipes.
(t) Valve Solenoid
(u) Air Filter Cat Part No as existing
Reassembling the diesel engine after top overhauling and installation in its original place/position including testing commissioning of DG Set complete all as specified and directed of following capacities:-
(a) DG Set 63/40 KVA cap Make Kirloskar
(b) DG Set 15/20 KVA cap Make Kirloskar/Cummins
Griding, polishing of cylinder head, cylinder valve seats, valve guide etc all as required for best overhauling for DG Set 63/40 KVA Make- Kirloskar/Ruston complete all as specified and directed
Griding, polishing of cylinder head, cylinder valve seats, valve guide etc all as required for best overhauling for DG Set 15 KVA Make- Kirloskar/Cummins complete all as specified and directed
Overhauling, servicing/calibration of FIP (fuel injection pump) assembly of DG Set 125/63/40 KVA Make: Kirloskar/Ruston including replacement of nozzle /injection delivery valve holders benjo bolt copper washer roater bearing etc including testing complete all as specified and directed.
Suppy and fixing following spares parts of FIP of DG Set 63/40 KVA Make: Kirloskar/Ruston complete all as specified and directed (only unserviceble parts shall be replaced after inspection):-
(a) Elements of FIP (Make MICO 1200240183)
(b) Nozzle (-do-) 1267230814
(c) Plunger
(d ) Delivery valve (-do-) 14185220471 HP
(e) Benjo Bolt (-do-) 29112037051 HP
(f) Seat Washer
(g) Bearing
(h) Tappet roller bush pin
(j) Control Rod 1416024007
(k) Fly weight assembly
(l) Governer spring
(m) Packing/Gasket 1411015052
Suppy and fixing following spares parts of FIP of DG Set 125 KVA Make: Kirloskar/Ruston complete all as specified and directed (only unserviceble parts shall be replaced after inspection):-
(a) Elements of FIP (Make MICO 1200240183)
(b) Nozzle (-do-) 1267230814
(c) Plunger
(d ) Delivery valve (-do-) 14185220471 HP
(e) Benjo Bolt (-do-) 29112037051 HP
(f)Seat Washer
(g) Bearing
(h) Tappet roller bush pin
(j) Control Rod 1416024007
(k) Fly weight assembly (MICO) 1428194000128
(l) Governer spring
(m) Packing/Gasket 1411015052
(n) Coolant for radiators
Overhauling, servicing/calibration of PT(Pressure Time) pumps assembly and Injector of DG Set 125 KVA Make: Cummins including replacement of Gear Pump /Pulsation Damper/ Teco Shaft/Main shaft and injector parts, Fly weight assembly bearing etc including testing complete all as specified and directed.
Suppy and fixing following spares parts of PT pumps and Injector of DG Set 125 KVA Make: Cummins complete all as specified and directed (only unserviceble parts shall be replaced after inspection):-
Gear Pump
Main Shaft
Techo Shaft
Throttle Shaft
Fly Weight assembly
Pulsation Damper
Bearing
Filter screen
Packing/Gasket Set
Barrel Plunger aasembly of Injector
Injector Cup of Injector
Supply and fixing of the following spares for DG Set 500/600 KVA Make- Jackson Kirloskar complete all as specified and directed :-
Oil Cooler Gasket
Oil Pan Gasket
Cylinder Head Gasket
Cylinder Head Cover Gasket
Water pump Gasket
Exhaust Manifold Gasket
Intake Manifold Gasket
O' ring Kit
Fan V Belt
Water Pump V Belt
Bearing
Cooling Nozzle
Thermostat
Impeller Water Pump
Sensor Tech complete
Water Separator
Supply , installation , commissioning and testing of Governor Controller Assembly complete Model - DWC-2000 Cat part No 65.11220.7008 CE certified . For 500 KVA DG sets Make - Jackson Kirlosker
Supply , installation , commissioning and testing of Digital Display Controller card complete for Electric Control Panel of 500/600 KVA DG sets Make - Jackson Kirlosker
Supply , installation , commissioning and testing of Electric Actuator Assembly complete for 500 KVA DG sets Make - Jackson Kirlosker
Supply , installation , commissioning and testing of self starter 24 Volt make Doosan or equilavent as per sample for DG Set complete for 500/600 KVA DG sets Make - Jackson Kirlosker
Supply , installation , commissioning and testing of Priming Pump complete for 500 KVA DG sets Make - Jackson Kirlosker
Supply , installation , commissioning and testing of Relief Valve assembly complete for 500 KVA DG sets Make - Jackson Kirlosker
Dimantling of FIP (fuel injection pump) assembly and FIP nozzles, Reassembling after repairing and calibration ,setting injection timing to aasure smoke less operation of DG Set 500/600 KVA Make: Jackson Kirloskar complete all as specified and directed.
Repairing/servicing/calibration of FIP (fuel injection pump) assembly of DG Set 500/600 KVA Make: Jackson Kirloskar including replacement of all unserviceable spare parts for 10/12 nos of cylinder engine of DG set including testing complete all as specified and directed.
Repairing and calibration of FIP Nozzle of DG Set 500/600 KVA Make: Jackson Kirloskar including replacement of all unserviceable spare parts for 10/12 nos of cylinder engine of DG set including testing complete all as specified and directed.
Opening of Cylinder Head , tappings , Griding, polishing of cylinder head, cylinder valve seats, valve guide etc and reassembling including tappet setting testing and trial complete all as required for best operation for DG Set 500/600 KVA Make- Jackson Kirloskar complete all as specified and directed
Rectification of water contamination i.e. water entering in Oil Chamber including replacement of seals and gaskets and nut bolts etc complete all as specified and directed
Repair of Governor Controller including setting and adjustment of Droop speed mode control Fuel control , stability controll, over speed control and testing complete of DG set Cap 500/600 KVA DG set Make- Jackson Kirloskar
Repair of Electric Control Panel of DG set of cap 500/600 KVA DG set Make- Jackson Kirloskar
Supply and fixing in replacement of Relay Card with Relay complete of Electric Control Panel of DG set of cap 500/600 KVA DG set Make- Jackson Kirloskar
Dismantling of radiator of DG Set 40 KVA/ 63 KVA / 125 KVA Make Kirloskar/ Ruston/Cummins complete all as specified and directed.
Repairing of radiator 40KVA/ 63 KVA / 125 KVA DG Set of make Kirloskar/ Ruston by brazing, soldering and cleaning of fins and descaling of tubes, replacement of new hose pipe set with clamp and fixing in original position and testing complete all as specified and directed.
Supply , and fixing including testing of radiator core of copper for 63 KVA DG set Make- Ashoka Leyland/Kirlosker/Ruston as per sample complete alla s specified and as directed.
Supply , and fixing including testing of radiator core of copper for 125 KVA DG set Make- Cummins as per sample complete all as specified and directed.
Dismantling unserviceable self starter 12 Volts of following capacity DG set of Make Kirloskar/ Ruston/Cummins and repair/maint by replacement of worn out parts like bendix pinion, piston, bush housing armature field coil, carbon bushes etc and refixing and testing for following cpacity complete all as specified and directed.
63 KVA & 40 KVA
Supply , installation , commissioning and testing of self starter 12/24 Volt make lucas/Bosch or equilavent as per sample for DG Set complete for 125 KVA DG sets Make - Kirlosker,Cummins
Supply , installation , commissioning and testing of self starter 12 Volt make lucas/Bosch or equilavent as per sample for DG Set complete for 63/40/20/10 KVA DG sets Make - Kirlosker,Cummins, Ruston
Dismantling, broken terminal shaft with MS cover for alternator of DG Set of any make /capacity and supply and connecting new terminal plates and cover of 1 mm thick MS sheet for alternator including cable connection complete all as required at site to complete the job as per approved sample complete all as specified and directed.
Dismantling of alternator from engine and stripping /opening replacement /rewinding the alternator with copper super enamelled wire of existing size and A class insulation for 63/125 KVA alternator make Kirloskar /Cummins /Crompton and refixing after alignment complete all as specified and directed.
S & F rectifier for DG Set 63/125 KVA cap Make Kirloskar complete all as specified and directed.
S&F Hr Run M/ Hr Meter including RPM Meter cable connection through Engine by making provision as necessary as per site requirement complete all as specified and directed.
S &F of turbo charger repair kit make ; Garrett Cat Part No. 0612321000 for 125/63 KVA DG Set Make - Kirloskar complete all as specified and directed.
S & F Core assembly of turbo charger Make Garrett complete all as specified and directed.
S & F Turbo charger garrett for kirloskar DG Set complete all as specified and directed.
S & F diesel fuel flexible pipe for DG Set of any capacity / Make complete all as specified and directed.
S&F of oil pressure pipe as per sample Make : Ashoka Leyland complete all as specified and directed.
S & F in repair hose pipe flexible Cat part AK 5040 SS of Make Cummins
S & F in repair hose pipe flexible Cat part AK 6065 SS of Make Cummins
S & F Oil cooler for DG Set 63 KVA/125 KVA capacity of make Kirloskar complete all as specified and directed.
S & F Lubricating oil pump for DG set 63 KVA/100 KVA capacity of make : Kirloskar and testing complete all as specified and directed.
S&F in repair cut out 12 Volts automatic of make : Lucas/Bosch and testing complete all as specified and directed.
S & F ignition switch with replacement of auto wiring suitable for DG Set of any capacity make complete all as specified and directed.
S & F battery charger suitable for charging of battery 12 Volts 90/180 AH with charging current 0-10 Amps, input voltage 230 Plus complete all as specified and directed.
S & F alternator for battery charging 12 Volts 180 AH with pulley complete all as specified and directed.
S & F battery cables of following sizes complete all as specified and directed:-
(a) 78 " long (+)
(b) 78" long (-)
S & F battery terminal brass heavy duty complete all as specified and directed.
S & F of battery charging meter (0-30) range complete all as specified and directed.
S & F oil temperature gauge Make AE, Dass Mesh, Siemens complete all as specified and directed.
Supply only distilled water in 5 Ltr Jericanes complete all as specified and directed.
S & F Anti vibration pad set for DG Sets as per site requirement complete all as specified and directed.
S&F Fan belt of following sizes complete all as specified and directed :-
Repair of Electric Panel of DG set capacity 125 KVA make- Kirlosker Bliss without any damage to the serviceable equipments complete all as directed.
Supply and fixing in replacement of following spares/parts of Electric Panel of DG set capacity 125 KVA make- Kirlosker Bliss
Pro com controller
Relay Card
Oil safety controller
Engine Temperature Safety controller
Battery charger 24 Volts
Connection plate
Push button with NO NC
Toggle switch
CT(current transformer) 6500T/6600T
Engine Harness
Panel Harness
OEM relay with base
LED lamp
Ampmeter
Repair/Maintenance of Automatic Voltage Regulator (AVR) of DG Set of Capacity 500 KVA/600 KVA installed at MH including replacement of all minor and major parts like Ics, Rectifier,diodes, capacitors, resistance, relay,Printed circuit board etc. and refix the same after complete repair and testing on load complete all as specified and directed.
Supply and fixing in replacement Automatic Voltage Regulator (AVR) of DG Set of Capacity 500/600 KVA of the existing make type and capacity and testing on load complete all as specified and directed. Make : as per existing/as recommended by OEM.
S&F in replacement Automatic Voltage Regulator (AVR) of DG Set of following Capacity. Make Cummins/Kirloskar/Ruston and testing on load, complete all as specified and directed. Note:- The AVR installation should be done through experienced electrician cum DG mechanic and the AVR should be capable of regulating and maintaining the desired Voltage rating after installation.
(a) DG Set 125 KVA
(b) DG Set 63/40/20 KVA
Supply and fixing in repair Battery 12 Volt 88 AH Make: Exide/Luminous complete all as specified and directed
Supply and fixing in repair Battery 12 Volt 150 AH Make: Exide/Luminous complete all as specified and directed
Supply and fixing in repair Battery 12 Volt 180 AH Make: Exide/Luminous complete all as specified and directed
Repair/maintenance of DG sets of any capacity ranges from 10 KVA to 600 KVA and any make and Model by qualified DG Set mechanic cum electrician by testing of complete units, and panels and governor Control setting and voltage fluctuation rectification including testing of self starter and battery and AMf panel and control panel etc and find out/detect the faults by setting/adjustment and rectify the defects in situ by using required spares and repair jobs and cleaning / normal maintenance to the DG Set complete to make the DG set functional in all respect complete all as directed by Engineer-in-charge. Note: (a) Spare parts and repair jobs of DG sets are measured separately under relevant items. (b) Register must be maintained by the contractor for the jobs carried out during breakdowns attending complaints and rectification of faults. (b) In this job only breakdown faults will be measured as a job. and Minor and other major repairs and periodical,general servicing and preventive maintenance will be not considered in this job it will be measured in the respective repair jobs/refixing of spares items sub part. (c)The complaint lodged regarding unserviceability of DG set must be attended by the qualified technician within 1 hour of complaint lodged and must be rectified on same day . A penalty of 1000 per day will be deducted from the contractor dues if complaints not attended or not rectified.
M&L for Earthing complete with galvanized earth plate electrode of size 60 cm x 60 cm x 6.00 mm buried directly in ground vertically at a depth not less then 2.25 Mtrs below normal ground level with top edge of earth plate at a depth not less then 1.5 Mtrs below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers made of galvanized iron and protected by light grade 40 mm dia GI pipe upto test point or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:3:6 type C2 (using 40 mm grade stone aggregate) including excavation and earth work in any type of soil, returning, filling in soil and disposal of surplus soil to a distance not exceeding 50 Mtrs all as specified and shown on plate No 05 of SSR Part I 1991.
M&Lin repair Galvanised iron strip of size 32x6 mm burried in ground/on wall ,
Refilling of fire Extinguser ABC type of capacity 10kg (incl monomonium phosphate and silicon and Pressure of nitrogen as required for 10 kg ) complete all as specified and directed.Note:-Cost of locking arrangement after refilling and painting work included in coated rate.
S & F in repair AMF panel for 125 kVA DG set complete all as spcd and directed
Rewinding of exciter coil of capacity up to 125 kVA DG set with copper wire complete all as spcd and directed.
Rewinding of exciter coil of capacity 500/600 kVA DG set with copper wire complete all as spcd and directed.
Repair of trolley four wheel incl welding work, nut-bolt etc and incl replacement of u/s tyre of size 750/16(4 nos.) to make it serviceable complete all as spcd and directed.
S&F in repair on load changeover switch 200 Amp four pole 415V phase for LT panel complete all as spcd and directed.
S&F in repair on load changeover switch 400 Amp four pole 415V phase for LT panel complete all as spcd and directed.
S&f in repair of charging motor suitable for ACB 2000 Amp capacity, complete all as spcd and directed.
S&F in repair of relay card for ACB 2000 Amp capacity,complete all as spcd and directed.
S&F in repair of complete relay for ACB 2000 Amp capacity,complete all as spcd and directed.
Servicing of ACB of capacity of 2000 Amp capacity,complete all as spcd and directed.
Notes: for Item No 02 to 209 (i) Complaints pertaining to DG Sets shall be resolved by the contractor within 24 hrs of getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 500 per day per complaint shall be imposed on the contractor. (ii) The contractor or his authorised representative shall report to the concerned JE E/M at 09:00 hours dailly on all working days to receive order/instructions of the work. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned. (iii) Work done register to be maintained by the contrator.
R&O Flt & LT External Electrification
Periodical maintenance of complete runway lighting system and repair by dismantling of air field/taxi track light fitting, AFL Cable & Connection of any description and segregatting to servicable and unserviceable parts and make it in serviceable condition by deploying person who have knowledge about Air field light system, Constant current regulator and Beacon light compelte all as specified and directed. Note (i) Replacement of spare parts will be measure and paid separately under respective item of schedule. (ii) T&P and HT insulation tape required for repair will be arrange by the contractor with his own cost. (iii) Day of maintanence/ repairs intimate by the dept prior to flying twice in a month. (iv) Failed to maintaining Runway light system for flying will be penalty of Rs 2000/- borne per job by the contractor.
S&F bipin halogen lamp 200 watt 6.6 Amp 50 HZ all as directed by Engr-in-Charge.
S&F bipin halogen lamp 45 watt 6.6 Amp 50 HZ all as directed by Engr-in-Charge.
S&F Bipin halogen holder for 200/45 watt lamps complete with chord complete all as specified and directed
S&F isolating transformer 200W, 6.6 Amp, 50 Hz all as directed by Engr In Charge. Make- Bildal/ AMA
S&F isolating transformer 45W, 6.6 Amp, 50 HZ all as directed by Engr In Charge.
S&F Protection Glass cover with washer for 200 watt runway light (Clear white) complete all as specified and directed.
S & F Protection Glass cover with washer for 45 watt Taxi track light (Blue) complete all as specified and directed.
S&F 6 Sqmm AFL cable connector (male female joint kit) complete all as specified and directed.
S&F in repair Run way light fitting 200 watt including lamp, 6.6Amp, Complete with outer lens, inner lens/filters, base plate rubber gasket, lamp, lamp holder isolating transformer etc complete all as specified and directed Make AMA ALN/Metro or equivalent
S&F in repair Taxi way light fittings 45 watt including lamp, 6.6Amp, Complete with outer lens, inner lens/filters, base plate rubber gasket, lamp, lamp holder isolating transformer etc complete all as specified and directed Make AMA ALN/Metro or equivalent
M&L for servicing, Oiling, greasing and testing of Beacon lights including replacement of unsv spares as required complete all as specified and directed.
S&F in repiar LED aviation obstruction light 12 Watt with fitting complete and making electric connections.Note :- Obstruction lights are to be replaced/fixed at Hangers/ATC
S&F in repair Approach light fittings 200 watt including lamp, 6.6Amp, Complete with outer lens, inner lens/filters, base plate rubber gasket, lamp, lamp holder isolating transformer etc complete all as specified and directed Make AMA ALN/Metro or equivalent
Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches, punning complete all as specified and directed Note:- Punning thickness of 18 cm will be considered for payment.
M&L for providing of new sub class 'B' Bricks, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Laying only old bricks complete all as specified and directed.
Taking out old unserviceable Old LT cable any type and size from trenches or fixed on poles or through pipes/walls/laid under roads/paths/ drains/culverts including Old Bricks complete all as specified and directed.
Supply and laying of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 185 Sq mm 3.5 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
All as per Ser item Ser No 233 here-in-before but 120 Sq mm 3.5 core
All as per Ser item Ser No 233 here-in-before but 95 Sq mm 3.5 core
All as per Ser item Ser No 233 here-in-before but 25 Sq mm 4 core
All as per Ser item Ser No 233 here-in-before but 16 Sq mm 4 core
All as per Ser item Ser No 233 here-in-before but 10 Sq mm 4 core
All as per Ser item Ser No 233 here-in-before but 10 Sq mm 2 core
S&F in replacement HT tropodome PVC insulated sheathed, AFL cable 6.6 Amps 5000 volts, with copper conductor 6 sqmm single core mltistranded including taking out of old cables complete all as specified and directed.
M&L in repair for boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50mm bore for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item.
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (a) 50 mm dia
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (b) 80 mm dia
S&F in repair bulk head fittings for landing T with 100W warm white lamp, holder with glass top cover and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 volt 50 Hz complete all as specified and directed.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / street light poles upto 3 mtr from furthest conductor / pole including removing of cut branches and cleaning of site complete all as specified and directed. Note:- (a) Tools & plants including safety measures equipments like belt, ladder & ropes etc shall be arranged by the contractor at own cost. (b) Contractor supervisor will take proper shut down before starting the work and clear it before resuming power supply, however full assistance will be provided by MES Staff.
Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: 1. Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid. 2. One RM length will be measured for 03 phase and one neutral one street light and one earth wire.
S&F in replacement stay assembly complete comprising of 20mm dia 40cm long stay bow rod 16mm dia x 1.8 Mtr long stay rod threaded and with nuts including 300mmx300mmx6mm thick plate necessary clamps etc as specified and directed. ( Note : Cost of Loop type insulator, stay clamp, stay wire, excavation and concrete included in quoted rate).
S&F in replacement shackle type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, complete all as specified and as directed.
S&F in replacement pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade, complete all as specified and as directed.
S&F in replacement, fabricating and fixing in replacement of cross arms (any type) supports, bracting, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed.
M&L for cleaning and preparation of old painted surface of LT steel tubular pole complete and painting with one coat of aluminium paint including channels/brackets, street light brackets, cross arms and making Black/Red/Yellow & white strips with synthetic enamelled paint of 30cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coat of white wash on PCC coping complete all as specified.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI wire 4mm dia with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR (Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Supply & fixing in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 02 mm dia aluminium binding wire all as specified & directed.
S&F in repair MCCB 415 Volts 4 pole 400 Amps 50 Hz 36 KA alongwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed. Make : L&T/Legrand /Havels/C&S. Note :- Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
All as per Item Ser No 254 here-in-before but of MCCB 250 Amps 4 pole 50 Hz 415 V, 25 KA
All as per Item Ser No 254 here-in-before but of MCCB 200 Amps 4 pole 50 Hz 415 V, 25 KA
All as per Item Ser No 254 here-in-before but of MCCB 125 Amps 4 pole 50 Hz 415 V, 16 KA
All as per Item Ser No 254 here-in-before but of MCCB 100 Amps 4 pole 50 Hz 415 V, 16 KA
S&F in replacement Isolator 4 pole 100 Amps, 415 Volts complete all as specified and directed.
Dismantling of LT PCC/Steel tubular pole of any size and discription incl coping, foundation etc complete all as specified and as directed.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
M&L for PCC type B1 (1:2:4) using 20 mm graded aggregate as in coping to the poles complete all as specified and directed.
M&L for PCC (1:3:6) type C2 using (40 mm graded aggregate in foundation, filing and mass concrete complete all as specified and directed.
M & L fabrication of MS Busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 250 Amp 36 KA incl making connection /thimbles complete all as sepcified and directed
Note : For Item No 212 to 264 (i) Day to Day Complaints pertaining to Street Light/LT External Electric Supply shall be resolved by the contractor immediatelly after getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 500/- per day per complaint shall be imposed from the contractor. (ii) The contractor or his authorised representative shall report to the concerned JE E/M at 09:00 hours dailly on all working days to receive order/instructions of the work. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned. (iii) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge.
Notes:- (a) Materials not included in sch of credit and debris from the dismantling having lowest value/Nil value shall be the property of department. The same shall be removed/ disposed or deposited by the contractor in MES stores yard of GE (West) Bareilly as directed for which no additional payment shall be made. The contracotor shall be fully responsible to safe guard these materials against losses/theft/deterioration etc till the same are deposited by him in MES Store yard (b) The contractor or his authorized representative shall attend office of AGE B/R for collection of complaints raised by user on regular basis and same has to be rectified /completed on requirement basis. If the contractors unable to rectify the complaints within stipulated time of 7 days (maximum), the penalty will be imposed to the contractor at the rate of Rs 500.00 per day for each complaint.
Notes- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
LEEJA ENTERPRISES (BID ID -3078913)
NOORI ENTERPRISES (BID ID -3094713)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .