| 1 | L1₹35.2 LAccepted-AOC H NO 31 DUPLEX MOTIAZ ROYAL FAME VILL CHAJJA MAJRA PO LANDRAN SEC 117 DISTT SAS NAGAR MOHALI PB PIN 140307 | S A S NAGAR | PUNJAB | 140307 | ₹35.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹36.3 LRejected-AOC 20 1 CHANDRA NIVAS APPLEBY ROAD WELLINGTON COONOOR THE NILGIRIS 643232 | 643232 | ₹36.3 L | L2 | Rejected-AOC L2 |
| 3 | L3₹37.0 LRejected-AOC 121004 | ₹37.0 L | L3 | Rejected-AOC L3 |
| 4 | L4₹37.4 LRejected-AOC 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | ₹37.4 L | L4 | Rejected-AOC L4 |
| 5 | L5₹38.9 LRejected-AOC | ₹38.9 L | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | P K ENTERPRISES L2 | AR Traders L4 | Jack Electrolinks Private Limited L6 | Dharm Singh Contractor L1 | eurekaenterprises L5 | Neptune Engineers and Builders L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and taking down unserviceable BER window AC of any capacity comprising of all connected accessories from existing locations and deposit to MES store yard complete all as specified and as directed. | 29 | Each Job | 400 ₹11,600 | 250 ₹7,250 | 2,500 ₹72,500 | 350 ₹10,150 | 600 ₹17,400 | 500 ₹14,500 |
| 2.00 | Material and labour for closing the existing opening with brick work in cement mortar 1:6 removed locations of window ACs, plastering in CM 1:4 , painting as matching to the existing surfaces complete all as specified and as directed. | 27 | Each Job | 800 ₹21,600 | 1,300 ₹35,100 | 2,500 ₹67,500 | 850 ₹22,950 | 5,000 ₹1.4 L | 1,500 ₹40,500 |
| 3.00 | Dismantling and taking down unserviceable BER split AC including dismantling of copper three core cable connecting MCB boxes, copper piping etc complete and making good the disturbed surfaces to match with the existing finish complete all as specified and as directed | 27 | Each Job | 400 ₹10,800 | 550 ₹14,850 | 2,500 ₹67,500 | 350 ₹9,450 | 600 ₹16,200 | 750 ₹20,250 |
| 4.00 | Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity (Inverter type) with HD filter complete with cordless remote control with in built display unit 5 star labelled, latest model energy efficent model eco friendly, 4500 Kcal / Hr, 50 Hz, 240 volts, air cooled condenser with 100% copper & Goldpin coating and 100% copper cooling coil with ocean black protection complete all accessories including fixing the out door unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/supports/making holes to pass the refrigerant pipes(by using core cutting machine) drain pipes to reach nearest drain, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant pipes with nitrile rubber insulation and control cable from indoor to outdoor upto a distance, Power cabling (Isolator/ Enclosure to unit), first charging of refrigerant gas including cordless remote, connection drain lines from unit to nearest drain points complete all as specified and as directed. | 38 | Each | 49,990 ₹19.0 L | 52,000 ₹19.8 L | 60,000 ₹22.8 L | 47,000 ₹17.9 L | 53,216 ₹20.2 L | 52,600 ₹20.0 L |
| 5.00 | Supply, installation, testing and commissioning of split air conditioning unit 2 TR capacity (Inverter type) with HD filter complete with cordless remote control with in built display unit 5 star labelled, latest model energy efficent model eco friendly, 6000 Kcal / Hr, 50 Hz, 240 volts, air cooled condenser with 100% copper & gold fin/blue fin coating and 100% copper cooling coil with ocean black protection complete all accessories varied speed including fixing the out door unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/supports/making holes to pass the refrigerant pipes(by using core cutting machine) drain pipes to reach nearest drain, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant pipes with nitrile rubber insulation and control cable from indoor to outdoor upto a distance, Power cabling (Isolator/ Enclosure to unit), first charging of refrigerant gas including cordless remote, connection drain lines from unit to nearest drain points complete all as specified and as directed. | 22 | Each | 69,900 ₹15.4 L | 73,000 ₹16.1 L | 72,500 ₹15.9 L | 67,000 ₹14.7 L | 70,928 ₹15.6 L | 67,500 ₹14.8 L |
| 6.00Note for Item Nos 4 & 5 : - (i) All outdoor units must be installed/ placed in service friendly location /as per the direction of Engr-in-charge. The bidder must visit the site before bidding to ensure feasibility of location to ensure requirement of refrigerant pipes/electrical fittings (ii) The bidder should install the AC by the auth rep of OEM and provide test certificate . (iii) The ACs should have warranty for 10 years on compressor, 05 yrs warranty on PCBs, fan motor (indoor& outdoor) & swing motor and 01 year comprehenssive warranty. In this condition the contractor has to submit the warranty certificate by the OEM/authorised dealer before claiming the RAR. (iv) Extra copper pipe from indoor unit to outdoor unit if required to be measured and paid separately under relevant items of this schedule. (v) Extra drain pipe from from indoor unit to nearest drain to be considered in the unit rate. (vi) Rate for taking down and refixing including making good incase of wall panelling included in the unit rate quoted. | |||||||||
| 7.00 | Supply and fix in repair 3 core multistranded copper conductor PVC insulated sheathed flexible cable of size 1.5 Sqmm complete all as specified and as directed | 78 | RM | 60 ₹4,680 | 150 ₹11,700 | 215 ₹16,770 | 400 ₹31,200 | 68 ₹5,304 | 145 ₹11,310 |
| 8.00 | Supply and fix in repair of copper tube of size both 5/8" & 1/4" from indoor unit to outdoor unit including nitrile rubber insulation for refrigerant line suitable for 2 ton AC all as specified and as directed | 48 | RM | 1,100 ₹52,800 | 500 ₹24,000 | 750 ₹36,000 | 1,788 ₹85,824 | 900 ₹43,200 | 1,050 ₹50,400 |
| 9.00 | Supply and fix in repair of copper tube of size both 1/2" & 1/4" from indoor unit to outdoor unit including nitrile rubber insulation for refrigerant line suitable for 1.5 ton AC all as specified and as directed. | 30 | RM | 1,100 ₹33,000 | 500 ₹15,000 | 650 ₹19,500 | 1,773 ₹53,190 | 968 ₹29,040 | 850 ₹25,500 |
| 10.00 | Supply and fix in repair MCB protected socket 4 module 20A, metal base, PVC plate (white) color cover plate suitable for upto 2.0 Ton AC with 16A 3 pin top, 20 A SP MCB 16A Scoket duly concealed on the surface/wall including making all electrical connection complete all as specified or as directed. | 58 | Each | 1,000 ₹58,000 | 800 ₹46,400 | 2,850 ₹1.7 L | 900 ₹52,200 | 1,040 ₹60,320 | 850 ₹49,300 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹94,280
Closing Date
29 Dec 2025, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
SPECIAL REPAIR FOR REPLACEMENT OF BER SUMMER APPLIANCES AT INS GADUDA NAVAL BASE KOCHI AND PROVN OF DEFICIENT AIR CONDITIOERS IN SERVER ROOM AT SECURITY COMPLEX BUILDING (P-305) AT INS GARUDA, NAVAL BASE, KOCHI
2025_MES_741988_1
8590/E8
Open Tender
Electrical and Maintenance Works
120 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹94,280
Yes
2 May 2026
28 Nov 2025
31 Dec 2025
28 Nov 2025
29 Dec 2025
13 Dec 2025
28 Nov 2025 - 29 Nov 2025
Amount
Dismantling and taking down unserviceable BER window AC of any capacity comprising of all connected accessories from existing locations and deposit to MES store yard complete all as specified and as directed.
Material and labour for closing the existing opening with brick work in cement mortar 1:6 removed locations of window ACs, plastering in CM 1:4 , painting as matching to the existing surfaces complete all as specified and as directed.
Dismantling and taking down unserviceable BER split AC including dismantling of copper three core cable connecting MCB boxes, copper piping etc complete and making good the disturbed surfaces to match with the existing finish complete all as specified and as directed
Supply, installation, testing and commissioning of split air conditioning unit 1.5 TR capacity (Inverter type) with HD filter complete with cordless remote control with in built display unit 5 star labelled, latest model energy efficent model eco friendly, 4500 Kcal / Hr, 50 Hz, 240 volts, air cooled condenser with 100% copper & Goldpin coating and 100% copper cooling coil with ocean black protection complete all accessories including fixing the out door unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/supports/making holes to pass the refrigerant pipes(by using core cutting machine) drain pipes to reach nearest drain, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant pipes with nitrile rubber insulation and control cable from indoor to outdoor upto a distance, Power cabling (Isolator/ Enclosure to unit), first charging of refrigerant gas including cordless remote, connection drain lines from unit to nearest drain points complete all as specified and as directed.
Supply, installation, testing and commissioning of split air conditioning unit 2 TR capacity (Inverter type) with HD filter complete with cordless remote control with in built display unit 5 star labelled, latest model energy efficent model eco friendly, 6000 Kcal / Hr, 50 Hz, 240 volts, air cooled condenser with 100% copper & gold fin/blue fin coating and 100% copper cooling coil with ocean black protection complete all accessories varied speed including fixing the out door unit with suitable stand as per site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/supports/making holes to pass the refrigerant pipes(by using core cutting machine) drain pipes to reach nearest drain, cables etc and making good to match with existing finishing complete, providing and making interconnection, including refrigerant pipes with nitrile rubber insulation and control cable from indoor to outdoor upto a distance, Power cabling (Isolator/ Enclosure to unit), first charging of refrigerant gas including cordless remote, connection drain lines from unit to nearest drain points complete all as specified and as directed.
Note for Item Nos 4 & 5 : - (i) All outdoor units must be installed/ placed in service friendly location /as per the direction of Engr-in-charge. The bidder must visit the site before bidding to ensure feasibility of location to ensure requirement of refrigerant pipes/electrical fittings (ii) The bidder should install the AC by the auth rep of OEM and provide test certificate . (iii) The ACs should have warranty for 10 years on compressor, 05 yrs warranty on PCBs, fan motor (indoor& outdoor) & swing motor and 01 year comprehenssive warranty. In this condition the contractor has to submit the warranty certificate by the OEM/authorised dealer before claiming the RAR. (iv) Extra copper pipe from indoor unit to outdoor unit if required to be measured and paid separately under relevant items of this schedule. (v) Extra drain pipe from from indoor unit to nearest drain to be considered in the unit rate. (vi) Rate for taking down and refixing including making good incase of wall panelling included in the unit rate quoted.
Supply and fix in repair 3 core multistranded copper conductor PVC insulated sheathed flexible cable of size 1.5 Sqmm complete all as specified and as directed
Supply and fix in repair of copper tube of size both 5/8" & 1/4" from indoor unit to outdoor unit including nitrile rubber insulation for refrigerant line suitable for 2 ton AC all as specified and as directed
Supply and fix in repair of copper tube of size both 1/2" & 1/4" from indoor unit to outdoor unit including nitrile rubber insulation for refrigerant line suitable for 1.5 ton AC all as specified and as directed.
Supply and fix in repair MCB protected socket 4 module 20A, metal base, PVC plate (white) color cover plate suitable for upto 2.0 Ton AC with 16A 3 pin top, 20 A SP MCB 16A Scoket duly concealed on the surface/wall including making all electrical connection complete all as specified or as directed.
P K ENTERPRISES (BID ID -3502604)
Neptune Engineers and Builders (BID ID -3510931)
AR Traders (BID ID -3504653)
eurekaenterprises (BID ID -3510539)
Jack Electrolinks Private Limited (BID ID -3504867)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
COMMONPAGES8590.pdf
Tender Documents • 0.49 MB
PS8590.pdf
Tender Documents • 0.53 MB
BOQ_830853.xls
BOQ • 0.86 MB
Download all tender documents and submit your bid