| 1 | L1₹22.0 LAccepted-AOC 38 41 28 104 AREA INDUSTRIAL ESTATE VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC Admitted being lowest | |
| 2 | L2₹23.8 L+₹31,893 (1.36%)Rejected-AOC | L2 | Rejected-AOC Not admitted being not lowest | |
| 3 | L3₹25.5 L+₹2.1 L (8.83%)Rejected-AOC D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L3 | Rejected-AOC Not admitted being not lowest | |
| 4 | L4₹26.7 L+₹3.3 L (14.0%)Rejected-AOC DOOR NO 44 19 10 RAILWAY NEW COLONY BEHIND SIVALAYAM VISAKHAPATNAM AP 530016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L4 | Rejected-AOC Not admitted being not lowest | |
| 5 | L5₹27.3 L+₹3.9 L (16.6%)Rejected-AOC HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L5 | Rejected-AOC Not admitted being not lowest |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
19 May 2023, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIR AND REPLACEMENT OF INTERNAL WIRING AND CONNECTED WORKS AT NAD CQAE CNAI DAD DSC AND ABE PARK UNDER AGE EM OF GE ND VISAKHAPATNAM
2023_MES_591983_1
8263GEND
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Visakhapatnam
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ND VIZAG
₹64,000
11 Aug 2023
28 Apr 2023
24 May 2023
28 Apr 2023
19 May 2023
12 May 2023
Amount
The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- [i] The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time. [ii] The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE. [iii] Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places. [iv] The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work). NOTE:- Tenderers/bidders are advised to vist the site and quote their rate accordingly and no claim whatsoever in this regard shall be admissible at any later stage.
Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 20mm PVC conduit totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point/5 Amp Independent board controlled by one switch including taking down the existing old wiring of any description and type complete all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cement and civil works and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
Description all as per item No. 2 above but for 05 Amp switch socket out let,on same board complete all as specified and directed
Description all as per item No. 2 above but for 15/16Amp switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified and directed
Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 25mm surface stove enamel steel conduit on walls/ceiling with tee, bend, elbows,junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity suitable for flame proof switches, sockets regulator and connected the earth wire to common earth dolly for One light point/fan point controlled by one switch complete all as specified and as directed.
Description all as per item No. 5 above but for 15/16Amp flame proof switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified and directed
Material and labour in repairs for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in existing 20mm PVC conduit concealed /surface conduit in walls/ceiling with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated concealed galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets regulator and connected the earth wire to common earth dolly for One light/fan point/bell point /5 amps independent board controlled by one switch including taking down the existing old wiring of any description and type complete all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cement and civil work and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
Description all as per item No. 7 above but for 05Amp switch socket out let,on same board complete all as specified and directed
Description all as per item No. 7 above but for 15/16Amp switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified and directed
S & F in repairs Modular switch 1 way 6A, 1 module single pole complete all as specified and directed
S & F in repairs Modular switch 2 way 6A, 1 module single pole complete all as specified and directed .
S & F in repairs Modular switch 1 way 16A, 1 module single pole complete all as specified and directed .
S & F in repairs ceiling rose surface bakelite 65 x 30 mm with 3 terminals complete all as specified and directed .
S & F in repairs of Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified and directed
S & F in repairs of Socket 15A/16A - 2/3 pin combined 2 module, 230 volt,multipurpose, complete all as specified and directed.
S & F in repairs Modular Bell push 1 way 6A, 1 module single pole complete all as specified and directed
S & F in repairs of modular Fan step regulator, 120W - 1 module complete all as specified and directed
S & F in repairs of modular Fan step regulator, 120W - 2 module complete all as specified and directed
S & F in repairs Switch flame proof switch socket and plug combined in LM6 cable termination box in LM6 ,16A 250 volt,2P+earth complete all as specified and directed.
S&F in repairs Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F switch piano flush type, 5 Amps 240 volts single pole one way complete all as specified and directed.
S&F switch socket combination 2 in 1, 5 amps flush type with back plate/frame complete all as specified and directed.
S&F switch socket combination 5/15 amps, 5 in 1, flush type complete all as specified and directed.
S&F socket outlet, 5 pin 15amps,flush type complete all as specified and directed.
S&F socket 5A/6A - 2/3 pin ,230 volt,multipurpose,flush type complete all as specified and directed.
S&F fan regulator electronic type, rotary step type , 240 Volt complete all as specified and directed.
S&F in repair Bell push flush type, 5 Amps complete all as specified and directed
S&F in repair buzzer Ding dong, AC 230 volts single pole complete all as specified and directed.
S & F 4 feet long LED tube light fittings, professional WH 5700K to 6200K and minimum 1800 lumens (18-20 Watt) of cool white / warm comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed
S & F 2 feet long LED tube light fittings, professional WH 5700K to 6200K and minimum 900 lumens (9 Watt) of cool white / warm comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed
S & F in repairs LED decorative mirror light fittings of minimum 900 lumens (9 Watt) of cool white / warm wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed
Supply and fixing in repairs post top lantern LED type 36/40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed
S & F in repairs square recessed mounted LED light (1'x1') of minimum 1500 Lumens (15 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed
S & F in repairs Square recessed mounted LED light (2'x2') of minimum 3600 Lumens (36 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Square recessed mounted LED light of round type for Ceiling cutout: Ø 160 mm, height 16 mm, 900 -1200 Lumens (9 - 12 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed
S & F in repairs Square recessed mounted LED light of round type for Ceiling cutout: Ø 210 mm, height 16 mm, minimum 1800 Lumens (18 Watt) warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs flood light , minimum 9000 to10000 Lumens (100 W) new generation LED with high luminous efficacy, IP66 protected, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed
S & F in repairs Highbay light minimum 12000 Lumens (120 W) new generation LED with high luminous efficacy, IP65 protected, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed
S & F in repairs Highbay light minimum 15000 Lumens (150 W) new generation LED with high luminous efficacy, IP65 protected, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed
S & F in repairs Building Security light LED type of minimum 3500 Lumens (35 W) Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed
S & F in repairs LED bulb non dimmable pin / thread type 9 watts with holder pin/thread type complete all as specified and as directed
S & F in repairs CMRI certified flame proof LED tube light fittings of not less than 4000 lm (40W) output 5700K, PF>0.95 with pressure die cast aluminium housing IP-65 protection heat resistance toughen glass cover, electronic driver all accessories internally prewired connecting with flexible copper conductor of size 1.5sqmm including taking down existing light fittings of any description all as specified and directed.
S & F in repairs CMRI certified flame proof LED bulkhead fittings of not less than 6000 lm (60W) output 5700K,PF>0.95 with pressure die cast aluminium housing IP-65 protection heat resistance toughen glass cover, electronic driver all accessories internally prewired connecting with flexible copper conductor of size 1.5sqmm including taking down existing light fittings of any description all as specified and directed.
S & F Energy efficeint LED Bollard type garden light fittings,10 W 230 Volts, including connecting up with three core PVC insulated sheathed flexible copper conductor cable of size 1.5 sqmm and making of basement with PCC for support of light complete all as specified and as directed.
S&F of metallic exhaust fan of sweep 300mm Heavy duty along with metallic louver complete including cutting of wall, making of proper hole sufficient to fix exhaust fan and smoothing of the surface before fixing of exhaust all as specified and directed
Supply, installation, testing & commissioning of Single Phase Digital Electronic Meter Hotpressed with and including SMC Meter box of size 250X250X155mm with viewing glass,concealed hinge and earth bolt plugged complete all as specified and directed Make: Sintex/Hensel
Supply & fix in repairs air ventilator PVC body 300mm sweep complete all as specified and as directed.
Taking down ceiling fan of any size from its position and doing complete overhauling of fan including replacement of fan clamp , split pin, rubber bush, 02 no canopy ,fan capacitor of 2.5mfd and other spares except rewinding including painting with two coats of synthetic enamel paint over a paint of primer refixing the same after repairs complete all as specified and directed .
Rewinding of ceiling fan motor of any type sweep & any make, with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, replacing the bearings of suitabe, etc. complete all as specified and directed
Taking down Exhaust fan of any size from its position and doing complete overhauling of fan including replacement of fan clamp and split pin, rubber bush, fan capacitor of 4.0mfd and other spare parts except rewinding, painting with two coats of synthetic enamel paint over a paint of primer refixing the same after repairs complete all as specified and directed
Rewinding of Exhaust fan motor of sweep upto 380mm & any make (including flamepfoof/normal type), with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, replacing the bearings of suitable size, etc. complete all as specified and directed
Rewinding of Exhaust fan motor of sweep 450mm & 600mm & any make, with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, replacing the bearings of suitable size, etc complete all as specified and directed
Taking down existing Air circulator / Pedestal fan of any type and sweep from any position and refixing the same in new / old position after necessary over hauling / servicing and cleaning for dust, grease except rewinding and applying one coat of synthetic enamel paint (spray painting) including filling the cavities with filler complete all as specified and directed
Rewinding of pedestal / Air circulator fan motor of sweep upto 600mm & any make, with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, replacing the bearings, capacitor of suitable capacity etc. complete all as specified and directed
S & F in repairs MCCB 4 Pole, 63 Amps, 50 Hz, 16KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as specified and directed
S & F in repairs MCCB 4 Pole, 100 Amps, 50 Hz, 16KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as specified and directed
S & F in repairs MCCB 4 Pole, 125 Amps, 50 Hz, 16KA, 415 Volts,adjustable thermal and fixed magnetic type with all necessary aluminium lugs and glands, etc complete all as specified and directed
S & F in repairs MCCB 4 Pole, 160 Amps, 50 Hz, 36KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as specified and directed
S & F in repairs MCCB 4 Pole, 250 Amps, 50 Hz, 36KA, 415 Volts, adjustable thermal and fixed magnetic typewith all necessary aluminium lugs and glands, etc complete all as specified and directed
Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 8 Way, IP-43 protection with 200 Amp rated bus bar and 4.0Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s including taking down old DB box of any type and making good with use of brick work, PCC 1:2:4 and cement mortar 1:4 and matching with existing surface, complete all as specified and directed
Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 4 Way, IP-43 protection with 200 Amp rated bus bar and 4.0Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s including taking down old DB box of any type and making good with use of brick work, PCC 1:2:4 and cement mortar 1:4 and matching with existing surface, complete all as specified and directed
Supply and fixing in replacement of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, IP-42 protection with 100 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s including taking down old DB box of any type and making good with use of brick work, PCC 1:2:4 and cement mortar 1:4 and matching with existing surface, complete all as specified.
Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 12 Way, IP-42 protection with 100 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s including taking down old DB box of any type and making good with use of brick work, PCC 1:2:4 and cement mortar 1:4 and matching with existing surface,complete all as specified and directed
Supply and fixing in repairs of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified and directed
Supply and fixing in repairs of MCB 63Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, , complete all as specified and directed
Supply and fixing in repairs of MCB 6 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified and directed
Supply and fixing in repairs of MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA 'C' series, , complete all as specified and directed
Supply and fixing in repairs of RCBO 4P 100mA, 40A to 63A , 415 Volt, complete all as specified and directed.
Supply and fixing in repairs of RCBO DP 30mA, 6 to 32A , 230 Volt, complete all as specified and directed.
Supply and fixing in repairs of RCBO DP 30mA, 40A to 63A, 230 Volt, complete all as specified and directed.
M&L for sub main wiring with four run of 10.0 Sqmm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sqmm drawn through PVC concealed/surface conduit of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 05 runs along with PVC concealed conduit shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6.0 Sqmm drawn through PVC concealed/surface conduit of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduit shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC concealed/surface conduit of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduit shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
M&L for sub main wiring with two run of 2.5 Sqmm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 2.5 Sqmm drawn through PVC concealed/surface conduit of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified and directed Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduit shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate.
Supply laying and testing of cable in trenches/walls, XLPE insulated, armoured electric cable (heavy duty 1100 volt grade with stranded aluminium conductor of size 95sqmm 3.5 core including taking out old cable complete all as specified and directed
Supply laying and testing of cable in trenches/walls, XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 70sqmm 3.5 core including taking out old cable complete all as specified and directed
Supply laying and testing of cable in trenches/walls ,XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 50sqmm 3.5 core including taking out old cable including taking out old cable complete all as specified and directed
Supply laying and testing of cable in trenches/walls ,XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 6 sqmm 2 core including taking out old cable complete all as specified and directed
Supply laying and testing of cable in trenches/walls, XLPE insulated, armoured electric cable (heavy duty 1100 volt grade with stranded aluminium conductor of size 25sqmm 4.0 core including taking out old cable complete all as specified and directed
Supply laying and testing of cable in trenches/walls ,XLPE insulated, armoured electric cable (heavy duty 1100 volt grade with stranded aluminium conductor of size 16sqmm 4.0 core including taking out old cable complete all as specified and directed
Supply laying and testing of cable in trenches/walls , XLPE insulated, armoured electric cable (heavy duty 1100 volt grade with stranded aluminium conductor of size 10sqmm 4.0 core including taking out old cable complete all as specified and directed
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed
Removing excavated surplus soils material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for natural river sand as cushioning of cables 23 cm Thick, including spreading and punning down to 18 cm thickness complete all as specified and directed . Note : punned thickness only shall be measured for payment purpose
Supply and laying in trenches un-reinforced pre cast concrete cable cover class LV,type I, flat size 250x150x40 mm complete all as specified & directed
Material and labour for 50 mm dia GI steel tubes 'light grade' for cable protection including sealing both ends complete all as specified and as directed
Material and labour for cutting existing road/ PCC/ drain for laying of underground cable and including necessary earth work and making good to match with the exisitng surface with PCC 1:3:6 type C1 using 20mm graded crushed stone aggregates complete all as specified and as directed.
Supply & fix in repairs single pointed air termination Aluminium rod, 12 mm dia, 300 mm long complete all as specified and directed.
Supply & fix Air termination vertical aluminium rod of length 2-3m long to provide class of protection-IV with foundation along with other accessories required at ground complete all as specified and directed.
Supply & fix in repair aluminium strip 25 mm x 3 mm Complete with saddles and fixing screws for Fitting the strip complete all as specified and directed.
supply and fix in repairs test point terminal box of size 200 x 100 x 100 mm made out of 2 mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15 mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosphorus Bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws,with frequient opening/closing arrangement etc complete all as specified and directed.
S & F in repairs Wall mounted AC plug and socket distribution box (Industrial socket) including plug connector 16 Amps, 2 pole and earth, IP 40 protection of metal body single phase 240 Volts, 50 Hz with provision for one 16 Amps MCB 2P including necessary fixing arrangements complete all as specified and directed
S & F in repairs Wall mounted AC plug and socket distribution box (Industrial socket) including plug connector of 32 Amps, 3 pole, neutral and earth, IP 44 protection of metal body three phase 415 Volts, 50 Hz with provision for one 32 Amps MCB TPN including necessary fixing arrangements complete all as specified and directed
S & F in repairs modular sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one MCB, SP, 20 Amps, 240 volts, 10 KA complete suitable for AC complete all as specified and directed
Supply and replacement of LED driver suitable for Flameproof Light fittings of 36/ 50/ 75 watt LED light of any type complete all as specified and directed
Supply and replacement of LED driver suitable for 36/50/75 watt LED light of any type complete all as specified and directed
Supply and replacement of LED driver suitable for 25/30 watt LED bldg security light of any type complete all as specified and directed
Supply and replacement of LED driver suitable for upto 20 watt LED light of any type (Garden Light/Post top lantern/recess mounted) complete all as specified and directed
Supply and fixing in repairs switch socket combination modular type with and including modular type PVC sunken box upto 8 module 2 pin & 3 pin 5Amp, 230 volt, multipurpose, 2 screw to fix on board complete all as specified and directed
Supply and fixing in repair switch socket combination modular type with and including modular type PVC sunken box upto 8 module 2 in 1 type, 3 pin 15/16Amp, 230 volt, multipurpose, 4 screws to fix on board complete all as specified and directed
S & F in repairs GI powder coated louvers suitable for exhaust fans 300mm sweep including replacing copper conductor wire complete all as specified and directed Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height.
S & F in repairs GI powder coated louvers suitable for exhaust fans 450mm to 600mm sweep including replacing copper conductor wire complete all as specified and directed Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height.
S & F in repairs 2mm thick GI hot dip galvanised / powder coated perforated type cable trays with cover of size 100mm width, 50mm depth fixed with and including necessary MS clamps, nuts, bolts fixed to walls / ceiling including taking down old cable tray complete all as directed
S & F in repairs PVC cable tray of size 100mm width, 50mm depth fixed with and including necessary end joints,T,bends and other accessories, MS clamps, nuts, bolts fixed to walls / ceiling including taking down old cable tray complete all as specified and directed.
S & F in repairs PVC cable tray of size 50mm width, 50mm depth fixed with and including necessary end joints,T,bends and other accessories, MS clamps, nuts, bolts fixed to walls / ceiling complete all as specified and directed
S & F in repairs PVC cable tray of size 75mm width, 75mm depth fixed with and including necessary end joints,T,bends and other accessories, MS clamps, nuts, bolts fixed to walls / ceiling complete all as specified and directed
M & L for Chemical earthing by drilling of hole upto 250mm dia to a depth not less than 3.5m and fixed sealed maintenance free chemical filled earthing copper electrode 3.048m long having the dia of 17.2 mm with coppercoating thickness of 254 microns, including supply and installation of CAPE make earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 -25kg buried directly and vertically in the hole with top edge not less than 1.25m below normal ground level connected with copper earth strip 30x6mm by means of bolts, nuts, check nuts and washers of copper connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, refilling the earthing hole including earthing lead upto 7.5m incl;uding taking out old earthing complete all as specified in SSR Part-I and all as per manufacturers instructions.]
M&L Earthing complete with copper plate electrode 600x600x3mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with copper earth strip of 20X3 mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 5, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & ,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 40mm dia light grade GI pipe for protection of strip including taking out old earthing complete all as specified and testing on completion.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth strip of 25X4 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 40mm dia light grade GI pipe for protection of strip including taking out old earthing complete all as specified and testing on completion.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber,CI frame with CI 10mm thick cover, 20mm dia GI medium grade pipe for watering , and water funnel with wirw mesh, 20mm dia light grade GI pipe for protection of strip including taking out old earthing complete all as specified and testing on completion.
M&L for 20X3 mm copper strip for earthing connection to building, complete all as specified and directed.
M&L for 25x4mm galvanised iron strip for earthing connection to building, complete all as specified and directed.
M&L for 4mm galvanised iron earth wire for earthing connection to building, complete all as specified and directed.
S & F in repairs LED Tube Light Batten Frame wall mounted with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable for and including 18/20W LED Tube Rod including taking down old fittings complete all as specified and as directed
M & L for Painting of complete LT Panels of any size and make with existing colour with 2 coats of synthetic enamel spray painting after cleaning of surface by scrubbing all dust particles/ grease/ oil etc and complete all as specified and as directed.
M & L for servicing of solar water heater with solar panel complete including necessary cleaning, brazing / welding & jointing of inlet outlet pipes (GI / UPVC), tanks,solar panels etc as per the site requirement and testing & checking of solar water heater and making in working condition using all necessary minor spares complete all as specified and directed NOTE:- servicing shall be carried out by an authorized engineer/Technician of OEM only and Sparesw parts of make as per original equipment only shall be used and contractor will have to submit necessary documents in this regard
M & L for taking down existing electric geysers of any type and capacity including dismantling the spares and cleaning, servicing the geyser by descaling inner body of water tank and cleaning it with soap and acid mixed water, brazing or welding of tank as required and reassembling the geyser set and refixing the same in original position including checking for proper function complete all as directed by Engr-in-Charge. [Note: Quoted rate is deemed to be inclusive for any minor spares such as nut & bolt auto cut, washers, indicating lamp etc as required. However geyser element & thermostat shall be measured and paid seperately]
Supply only geyser element 1.5 KW / 2.0 KW capacity complete all as specified and directed . Note :- Fixing of element shall be included in Item No 119
Supply only Thermostat of necessary capacity (1.5/2 KW) complete all as specified and directed . Note :- Fixing of Thermostat shall be included in Item No 119
S&F in repairs Hot and cold pipes complete along with ncessary nuts and bolts as required and as specified and directed.
S & F in repairs of modular Cover Plate and Frame 1 module to 4 module suitable for Modular switch/socket complete all as specified and directed.
S & F of modular Cover Plate and Frame 6 module to 8 module suitable for Modular switch/socket complete all as specified and directed.
Taking down old metal flush box of any type and S & F in repairs of modular Metal Flush Box 1 module to 4 module suitable for Modular switch/socket complete all as specified and directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work and making all the disturbed surfaces of wall good to match the existing wall along with same colour.
Taking down old metal flush box of any type and S & F in repairs of modular Metal Flush Box 6 module to 8 module suitable for Modular switch/socket complete all as specified and directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work and making all the disturbed surfaces of wall good to match the existing wall along with same colour.
ESWAR ENTERPRISES
ANAND ENTERPRISES AND ENGINEERS
ANJALI ENTERPRISES
SAMPATH ENTERPRISES
MVV Prasad
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
SAI SAMPATH ELECTRICAL AND ENGINEERING
SRI SAI VAGDEVI BUILDERS
SONI ENGINEERS CONTRACTORS
S R CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .