Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.2 L+₹74,793 (2.72%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹29.0 L+₹1.5 L (5.39%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹32.2 L+₹4.7 L (17.2%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹33.2 L+₹5.7 L (20.8%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Aug 2023, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura Jamnagar - 361150
Maintenance and repair of VCBs/ Ring Main Units/ Distribution Transformers, LT Panels and connected works at INS Valsura, Jamnagar
2023_MES_606221_1
8690/VAL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹60,000
Yes
8 Sept 2023
27 Jun 2023
5 Aug 2023
27 Jun 2023
3 Aug 2023
22 Jul 2023
Amount
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L for cement concrete 1:3:6 type C1, using 20mm graded crushed stone aggregate as in copings, kneelers, apex stones, bed plates, pedestal of electric poles and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 60cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed.
M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed. Notes :- (i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
Taking down carefully old existing HT PCC Cable Cover of Class EHV / HVP / HV of any type & size complete all as specified & as directed.
Laying only HT PCC cable covers of any type & size for protection of UG electric cables in trenches, obtained serviceable from serial item No. 7 here-in-above, complete all as specified & as directed.
Supplying and laying un-reinforced precast cement concrete cable covers, Class HV, Type-1, Flat, size 300 mm x 180 mm x 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and as directed.
Taking down carefully old existing LT PCC Cable Cover of Class LV of any type & size complete all as specified & as directed.
Laying only LT PCC cable covers of any type & size for protection of UG electric cables in trenches, obtained serviceable from serial item No. 10 here-in-above, complete all as specified & as directed.
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type-1, Flat, size 250mm x 150mm x 40mm for protection of underground cable in trenches complete all as specified and as directed.
Supply and laying/fixing 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
M&L for Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
All as per serial item No. 14 here-in-above, but 80mm bore.
Supply, laying, jointing and testing HT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium stranded conductor 11000 Volt (Earthed) grade of cross sectional area 95 Sqmm, 3 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc, including dismantling & taking out old unserviceable HT cable, complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 300 sqmm 3½ Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
All as per serial item No. 17 here-in-above, but cross-sectional area 185 Sqmm 3½ Core.
All as per serial item No. 17 here-in-above, but cross-sectional area 120 Sqmm 3½ Core.
All as per serial item No. 17 here-in-above, but cross-sectional area 50 Sqmm 3½ Core.
All as per serial item No. 17 here-in-above, but cross-sectional area 16 Sqmm 4 Core.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 1100 V grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/XLPE armoured aluminium conductor cable of size 16 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for 1100 V grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
All as per serial item No. 26 here-in-above, but size 70 Sqmm to 95 Sqmm.
All as per serial item No. 26 here-in-above, but size 120 Sqmm to 185 Sqmm.
All as per serial item No. 26 here-in-above, but size 240 Sqmm to 300 Sqmm.
All as per serial item No. 26 here-in-above, but size 400 Sqmm to 500 Sqmm.
S&F Danger notice plate of 25x20cm size, 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour for HT 11000 Volts and fixed with suitable MS clamps made out of flat iron 25x3mm, bolts and nuts of approved size, fixed in repairs, complete all as specified & as directed.
M&L for servicing and repair to HT RMU/ VCB of size up to 630 Amp complete by taking the shut down with prior intimation and cleaning the contacts & servicing of HT fuses, bushes, all type of coils, contactors, springs, motors, relays, limit switches, CTs, etc and put the trolley in position and testing complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Shunt trip coil for HT VCB of C&S make
S&F in repairs closing coil for HT VCB of C&S make
S&F in repairs spring charging motor for HT VCB of C&S make
S&F in repairs Limit switch of type LSMS11, AC 15 A, 3A/400 V for HT VCB of C&S make
S&F in repairs Limit switch of type MU25-I/l 2, 16 A/250 V AC for HT VCB of C&S make
S&F in repairs Breaker control switch 10A, spring return to neutral 3 position & label trip-neutral-close for HT VCB of C&S make
S&F in repairs Hand reset master trip relay, aux-110V DC (CLR-H-3). Make: C&S
S&F in repairs IDMT non directional O/C & E/F relay aux.-110V DC (IRI-PRO-3I-EI-5-5) complete all as directed.
S&F in repairs HT HRC fuse of 10 to 63 Amp as per sample. Make: L&T/ Bussmann or equivalent as approved by GE.
S&F in repairs CT's 200-100/5-5A dual core, resin cast ,core 1:- metering-15VA CL-1, core2:- protection-15VA CL-5P10, STC-18. 4kA for 3s
S&F in repairs CT's 100-50/5-5A dual core, resin cast, core1:- metering-15VA CL-1, core2:- protection-15VA CL-5P10, STC-18.4kA for 3s
S&F in repairs VT 11kv/ √3/110 vac/√3, 200VA, CL-1, 1 phase resin cast
S&F in repairs digital HTCT Meter (Trivector Meter), Class 0.5s (Base Mounting), 3 Phase 4 wire, 4 Quadrant measurement, Anti-tamper features, with CT 200-100/5A including all accessories complete all as specified & as directed. Make : L&T Model ‘ER300P’ Cat No. WR300BB5200 or equivalent in makes mentioned in Appendix 'B' here-in-after, as approved by GE).
S&F in repairs Analog Ammeter 0-100-200A CTR-200-100/5A CL-1 size 144x144mm
S&F in repairs Analog Ammeter 0-50-100A CTR-100-50/5A CL-1 size 144x144mm
S&F in repairs 0-15kV analog Voltmeter PTR-11kv/110 vac. Size - 144x144mm
S&F in repairs HT fuse 11kV/3.15A, length - 195mm, diameter - 25.4mm
S&F in repairs LED type indication lamp red, yellow, blue colour 63.5v ac, dia - 22.5mm
S&F in repairs LED type indication lamp red, green, blue, white colour 110v ac, dia - 22.5mm
S&F in repairs Space heater 80W 230V AC for 11kV HT electric VCB
S&F in repairs Thermostat 0-110°C 15A 230V AC for 11kV HT electric VCB
S&F in repairs VCB breaker mechanism for 11 kV HT electric VCB
S&F in repairs Spout of VCB/RMU of 11kV
S&F in repairs PT Spout of VCB/ RMU of 11kV
M&L for Power pack suitable for VCB with Input Voltage 230V, AC, O/P -110 V DC, with LED indication showing Main ON, Battery Mode, Battery Low, Out Put O/Load etc complete all as per existing type.
Disconnecting/ Taking out the existing transformer of the capacity upto 400 kVA from site for repairing and transporting to workshop for servicing and repairing including loading, unloading and handling to carry out the necessary repairs and refixing the same after & including checking of all parts for repair/ replacement, repairing, installation, testing and commissioning at its original/ new location, decanting the transformer oil, etc, for smooth functioning, complete all as directed by Engineer-in-Charge. Notes :- (i) Necessary spare parts required replacement shall be replaced only after prior inspection & approval of Engineer-in-Charge and replacement shall be measured & paid for separately under relevant items of this Schedule. (ii) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. (iii) All T&P & transportation shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted.
Rewinding of coils all as per its original specifications by new copper conductor and with HT/ LT necessary insulation materials.
Replacement of HT 11 KV bushing assembly with brass terminal, neoprene rubber gasket and washers etc complete with accessories for transformer of capacity upto 400 KVA.
Replacement of LT bushing assembly with brass terminal, neoprene rubber gasket and washers etc complete with accessories for transformer of capacity upto 400 KVA.
Supply and filling new Transformer oil up to conservator level marking as per IS-335 having dielectric strength not less than 40 kV at 2.5mm gap complete all as specified and as directed. Make : Electrol, Power Oil, Indian Oil, Savita or equivalent as approved by GE. Note : Transformer oil shall be supplied in sealed barrels with test certificate. Cost of barrel shall be deemed to be included in the unit rate quoted by the contractor and empty barrel will be the property of the Department and same shall be deposited to the AGE E/M Store Yard. Nothing extra shall be paid on this account.
Replacement of Silica Gel blue in crystal in existing transformer breathers for transformer of capacity upto 400 KVA.
Replacement of HT 11 KV off-load Tap changing assembly complete for transformer of capacity upto 400 KVA.
M&L for preparation of external surfaces of distribution transformer of capacity upto 400 KVA including cleaning and removing oil spots from the body and painting with one coat of synthetic enamel paint (first quality) of approved tint with gun sprayer including marking of SM/MES No etc. on transformer with synthetic enamel paint (white) complete all as specified and as directed.
M&L for filtration / dehydration of old/existing transformer oil including topping up of transformer oil as required in the transformers of different capacity, installed at various locations with suitable capacity of filtration machine to achieve dielectric strength minimum 60 KV complete all as specified and as directed. Notes: (i) All necessary T&P / testing equipment shall be provided by the contractor at his own cost. No extra payment shall be made to the contractor. (ii) New Transformer Oil required for topping up shall be paid for separately under relevant item of this Schedule.
M&L for preparation of old painted steel surfaces by cleaning, removing rust, grease and apply one coat of 1st quality synthetic enamel paint of approved tint (Spray painting outside /inside surfaces) by removing and re-fitting of switch gears/ busbar of the feeder pillar box/ LT Panels Outdoor/ Indoor type of any size complete with prior permission of Engineer in Charge. Base frame shall be painted with Black synthetic enamel paint and including writing the SM No. / MES No. on Panel/ Feeder pillar box in white synthetic enamel paint complete all as specified and as directed.
S&F locking arrangement with MS aldrop bolt set (mild steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet) complete of size 225 mm to existing feeder pillar box by welding including taking down old worn out locking arrangement complete all as specified.
M&L for galvanised iron strip 32 x 6mm earth continuity conductor or main earthing lead buried in ground / fixed on wall with suitable porcelain insulators including taking out existing GI strip complete all as specified and as directed.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing of any type. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M/s Balaji Enterprise
BHAVNA IMPERIAL ENTERPRISE
Ravi enterprise
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .