| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | ₹16.6 L Quoted ₹17.0 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹18.5 L+₹1.4 L (8.42%)Rejected-AOC | ₹18.5 L+₹1.4 L (8.42%) | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Jun 2023, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/ MAINT TO PCC ROAD, PATH /CULVERT/HARD STANDING, DRAIN AND COMPOUND WALL AND CLEANING OF SEPTIC TANK/ SOAK WELL AT TECHNICAL AND RESIDENTIAL AREA ITM MUSSOORIE, DEHRADUN
2023_MES_597732_1
GE(I)RND/9250/E8/23-24
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Class E Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹40,000
Yes
26 Jun 2023
23 May 2023
21 Jun 2023
23 May 2023
19 Jun 2023
30 May 2023
23 May 2023 - 30 May 2023
Amount
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth in soft/ loose soil for foundation, etc. or for shafts, wells cesspits, manholes, pier holes etc and getting out complete all as specified and directed.
All as per item No 2 above but exceeding 1.5 deep and not exceeding 3m deep complete all as specified and directed.
M&L for returing filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing of excavated material (Soil) to a distance exc 250m but not exceeding 500 mtr and depositing at a level n.exc 1.5 m above the starting points complete all as specified and directed.
Demolition of ( reinforced cement concrete) (reinforcement cut as required to facilitiate demolition) of any description and in any positionnot otherwise specifically provided for and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
M&L for reinforced Precast cement concrete(1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) as in landing , cover slab (for manholes, shelves), chullah hoods, chajjas, water troughs , mangers, shelves and similar articles with plain faces incluing necessary form work, & set in Cement Mortar (1:4) complete all as specified an directed. Note:-Reinforcement shall be measured and paid for separately in respective items of Sch "A"/BOQ
M&L for Mild Steel TMT bar, 8 mm dia & Over , cut to length, bent to shape require, including cranking , bending spirally for hooping for columns ,hooking ends and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise described and removal of dismantling materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165 complete all as specified and directed.
Demolition of brick or stone boulders masonary built in cement mortar or cement lime mortar including all quions, arches pillars etc but excluing ashlar facings ressed stone works and precast concrete artiles of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
M&L for Walling of random, rubble, stone masonary brought upto courses, well bonded bedded and soilidly hearted and built in cement mortar (1:6) complete all as specified and directed. Note:- The PCC bond stones as use in random, rubble, stone masonary shall be mesured and paid serpartily under recepective item of BOQ.
All as per Ser item No 12 above, but except stone complete all as specified and directed.
M&L for raised pointing to random or polygonal rubble masonry, uncoursed or brought upto courses in CM 1:4 complete all as specfied and directed.
M&L for Extra over stone walling for hammer dressing to face stone with max depression on face from straight edge held against the dressed surface not exc 40mm and dressing of face and joints as specified of random rubble walling uncoursed or brought upto coursed or lime or sand stone complete all as specfied and directed.
M&L for Brick work with sub class ‘B’ bricks, straight or curves on plan exc 6 mtr mean radius using old size bricks built in Cement Mortar (1:4), complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in lintels upto 1.5 clear span , cills steps seismic and other similar bands,bond stone copings, hold fast and the like incluing weathering , slightly rounded or chamfered angles and throating asdirected with and icluding necessary form work in CM 1:4 complete all as specified an directed.
M&L for Rendering 15mm thick in CM (1:4) on fair faces of brick masonry/ concrete surface on wall with using liquid water proofing compound and finishing the surfaces even and smooth without using extra cement , complete all as specified an directed. Note:- WPC shall be measured & paid for separately as “Supply only item under respective items of Sch "A"/BOQ.
Supply only liquid water proofing compound ISI marked complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc and removing of debrish to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:6, on fair faces of brickwork or concrete surfaces, surface finished fair and even without using extra cement, etc complete all as specified and directed.
M&L Concrete bed 150mm dia to drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; in PCC (1:4:8) type D-2 complete all as specified and directed.
All as per item No 22 above but for 200mm dia of pipe complete all as specified and directed.
M&L 150mm internal dia of pipe salt glazed stoneware drain pipe Grade 'A' laid in trenches and jointed in cement & sand morater 1:1 and testing complete all as specified and directed.
All as per item no 24 above but for 200mm internal dia of pipe complete all as specified and directed.
Demolition and breaking up Drain pipes (SGSW, AC or reinforced concrete) 150mm bore set in cement mortar and removing of debrish to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
Demolition and breaking up Drain pipes (SGSW, AC or reinforced concrete) 200mm bore set in cement mortar and removing of debrish to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type -B1, smooth finished , and reforming benching as required complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains 200mm dia making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type -B1, smooth finished , and reforming benching as required complete all as specified and directed.
Demolition of plain cement concrete ( Un reinforced)of any description in any position not otherwise specifically provied and removal and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
M&L Plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate as in foundation filling & Mass concrete , sub base complete all as specified and directed.
M&L providing 100mm thick PCC (cement concrete) 1:2:4 etc type B-2 (using 40 mm graded stone aggregate ) pavement/ramp/floor finsihed even an smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in surface channel and drain incluing necessary form work complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles complete all as specified and directed.
M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of size 350x250x7mm/ 450x350x7mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
M&L for non skid Ceramic tiles,first quality( of approved class , colour and design/ shade ) 6 to 7 mm thick( square/ rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, ,as in floor surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over and including 15 mm Screed bed in CM 1: 6 complete all as specified and directed.
S&F in repair white vitreous China wash down water closet pan (pedestal) pattern, and trap (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. with and including plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device and 15mm dia chromium plated brass washing jet fixed to water closet with 15mm dia and 1.2m to 1.5m long flexible pipe with chromium plated spring type cover complete with fixing arrangement fancy look complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest (excluding flushing cistern and flush pipe) & including CI trap & connecting fitting as required set in plain cement concrete (1:3:6) type C-1 and connecting to flusing cistern and trap & connecting fittings as required and making good to floor as per existing complete all as specified and directed.
S&F in repair Vitreous China urinals, half stall type white urinal, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S&F in repair PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed.
Taking down Cast iron/PVC pipe of any dia and size fixed on wall or floor including all fittings and removing of debrish to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
S&F 110mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in 110mm dia PVC(SWR) bends/ shoes any radius complete all as specified and directed.
S & F in PVC (SWR) floor trap 75 mm, plain with grating incl setting and jointing with solvent cement complete all as specified and directed.
S & F in PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F in 75 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in 75 mm dia PVC(SWR) bends/ shoes any radius complete all as specified and directed.
Disconnecting & taking down existing water tank of capacity exc 250 litres and not exc. 500 litres and removing from site complte and S&F rotational moulded polyethylene water storage tanks 500 lts capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position complete all as specified & directed.
M&L Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc., capacity of tank exc 250 & n exc 500 litres including writing date of cleaning on the tank with suitable synthetic enamel paint etc complete all as specified and directed.
M&L Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc., capacity of tank exc 500 litres & n exc 1000 litres including writing date of cleaning on the tank with suitable synthetic enamel paint etc complete all as specified and directed.
M&L for Cleaning of septic tank up to 25 users by removing sludge in semi solid shape / state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5 km but n exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for Cleaning of septic tank exc 25 users and not exc 50 users by removing sludge in semi solid shape / state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5 km but n exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for Cleaning of septic tank exc 50 users and n.exc 100 users by removing sluge in semi solid shape / state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for Cleaning of septic tank exc 100 users and n.exc 200 users by removing sluge in semi solid shape / state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for Cleaning of septic tank exc 200 users and n.exc 300 users by removing sluge in semi solid shape / state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for Dewatering of soak well or sewage of any dia and depth manully or by using pumps and removal of sludge if any to a distance exc1.5km but not exc 2Km out of MOD land and buried into ground by digging pits and spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for cleaning with suitable chemical of P/S trap of EWC/IWC etc by removing all blockage of any description in any situation in the system and removal of sludge in semi solid shaped state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out ofMOD land and buried into ground by digging pits and spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for cleaning of Nahani/floor trap of Bath/kitchen/urinal/ wash basin incluing Ist gully trap etc by removing all blockage of any description in any situation in the system and removal of sludge in semi solid shaped state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out of MOD land and buried into ground by digging pits and spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for cleaning of Sewage pipe line from gully trap to ISt manhole an then upto the final drop into the septic tank an soak well /cess pool (except intermediate manholes ) by removing all blockage of any description in any situation in the system complete any ia of pipe an epth by rodding ,manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out of MOD land and buried into ground by digging pits and spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for cleaning of manholes any type-size and any depth by removing of sludge in semi solid shape / state or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out ofMOD land and buried into ground by digging pits and spray a layer of bleaching powder @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed.
M&L for glossy finish rubber moulded chequered cement concrete tile 30 cm x 30 cm x 25 mm thick set jointed and pointed in neat cement slurry in floor with grey cement and pigment to match over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finished complete all as specified and directed.
M&L for injecting chemical GLYPHOSPHATW 41% SL 20 ml or till refusal by makimg cut/ injection in the stem ofplant 30mm C/C spraying with solution (25ml Glyphospoto 41% diluted with one litre water) and removing the plants/ vegetation upto five story height of building including penefreated roots complete including necessary scaffolding etc complete all as specified and directed.
M&L for road cutting as desired for laying of Sewage line pipes of any description and size including sub base, hard core and stone saling etc of any description below the ground level up to any depth complete all as specified and directed.
S&F mild steel angle iron in fencing posts, and struts fixed independently without connecting plates, grill etc and cutting to required size and shape, conforming to gde Fe 410-W (Gde E-250) Quality including dismentaling of existing fencing post any type and size. Complete all as specified and directed.
S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of fencing posts including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc including Dismentling of barbed wire of any description of any position Complete all as specified and directed.
M&L Preparation of new plastered surfaces of walls and concrete work and applying two coats of cement based paint complete all as specified and directed.
M&L for Preparation old plastered or unplastered surfaces of walls and concrete work and applying one coat of cement based paint complete all as specified and directed.
M&L for Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer. Complete all as specified and directed
M&L for Preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint Complete all as specified and directed
S & F in repair 1.00 mm thickness of laths steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, complete : push pull or manual type complete all as specified and directed.
M&L for cleaning of open/covered drain and applying a spray of bleaching powder @ 1.00 Kg/Rm area for helthy hygenic atomoshphare including removing of sludge from existing site to a minimum distance of 1.5 Km from the crowded area and also spray of bleaching powder @ 1.00 Kg / Sqm on sludge obtain from existing site complete all as specified and directed.
M&L for vitrified ceremic paver tiles of size 400mm x 400mm x 12mm thick coloured, heavy duty with grey cement and pigment set and jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for S&F stainless steel framed work such as in grills, gratings, etc. with end of bars shouldered and/or riveted , or forged in to spikes, framed guard bars, barred iron doors, ladders, framed blusters, walk ways, railings, framework of water tanks and similar work complete all as specified and directed.
M&L for S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
M&L for S&F Pre- painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
M&L for 3mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors supplied and laid in repair complete all as specified and directed.
M&L for PVC sheet wall penelling of thickness 5mm solid consisting of panels of desired size stuck on inner frame work of 50 mm wide strips of 5 mm thick prealam PVC sheet. The panel & strips shall be of 600 Kg/Cbm density manufactured by an ISO-9000 certified company. The strips should two PVC PVC strips. The PVC strip shall be fixed to the wall using 65 mm long MS screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200 mm. A groove of 2m may be left at the joint of two panels for astheticlooks. The exact size of the panel and orrespondingly of the gird may very depending on the size of the wall. Optionally a U channel at top, bottom and strip of 5mm thick PVCsheet of width 75 mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement complete all including dismentling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. (Note:- Including all necessary fittings and scafolding for working at any height).
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Paymentfor providing grooves shall be made separately). complete as specified and directed.
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge complete as specified and directed.
Supply and fixing galvanised chain link fencing, of size 4mm dia and mesh size 75 x75 mm to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed.
M&L for Mild Steel screw bolts 10 to 12 mm dia (machine made ) with hexagonal or squre head at one end and screwed the other or screwed both ends to be fitted with washers and one hexagonal or squre nuts exc 15 cm but n exc 30 cm long complete all as specified and directed.
M&L for Writing letters or figures (Block, Roman, Italic or Indian) incl dash, comma and arrow etc with Radium tape night glow in dark of approved colour, width of tape 20mm and height n exc 200mm, on board of Acryatic metal sheet complete all as specified and directed.
Ram Naresh Singh Sikarwar
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .