Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.2 CrAccepted-AOC 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | ₹2.2 Cr | L-1 | Accepted-AOC AOC |
| 2 | L-2₹2.4 Cr+₹19.2 L (8.70%)Rejected-Finance 164 A 11 GALI NO 3 RISHI NAGAR KAITHAL 136027 | KAITHAL | HARYANA | 136027 | ₹2.4 Cr+₹19.2 L (8.70%) | L-2 | Rejected-Finance Highest |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
5 Aug 2021, 5:00 pmClosed
Navin Kumar
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Widening with cement concrete pavement on Radaur Jathlana upto Model Town road in Yamuna Nagar under NABARD RIDF-XXV Head for the year 2020-21 of Public Works (B and R) Deptt, Haryana (Pdg. Utility Shifting) (Recall).
2021_HRY_174339_2
PWD/Elect-KNL/Elect-AMB/110161
Open Tender
Construction Works
Works
120 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹3.2 L
12 Oct 2021
23 Jul 2021
6 Aug 2021
23 Jul 2021
5 Aug 2021
23 Jul 2021
Amount
Providing 11 mtr long PCC pole complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-1
Providing of stay set complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-2
Providing of stay wire complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-3
Supply of ACSR conductor wire with accessories including stringing and sagging of conductor of various sizes as well as jointing and binding with insulator at supports complete in all respect up to entire satisfaction of Engineer-in-charge of the work. 50 sqmm HSR No. NS-4 (i)
Supply of GSL wire 8 SWG complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work HSR No. NS-5
Supply of MS channel 100x50x6mm galvinized including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. HSR No. NS-6
Supply of MS angle 50x50x6mm galvinized including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. HSR No. NS-7
Supply of MS flat 50x6mm galvinized including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. HSR No. NS-8
Providing of Nut & Bolt of size as per specification of Engineer-in-charge. HSR No. NS-9
Supply of Disc insulator for HT Stay polymer T&C type complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work HSR No. NS-10
Supply of HT XLPE cable including the cost of i-bolt for holding of cable etc. including required material to erect on existing PCC pole complete in all respect up to entire satisfaction of Engineer-in-charge of the work. 185sqmm 3 core. HSR No. NS-11 (i)
Supply of Cable Box O/D HSR No. NS-12
Supply of Suspension clamp with eye hook wooden cleat complete in all respect upto the entire satisfaction of Engineer-in-Charge. Suspension clamp. HSR No. NS-13
Supply of Dead end clamp with eye hook wooden cleat complete in all respect upto the entire satisfaction of Engineer-in-Charge. Dead end clamp. HSR No. NS-14
Supply of 11KV gang operated switch for 11 mtr pcc pole conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing 'H'pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works. HSR No. NS-15
Supply of Disc insulator with fitting & for staymake T&C type complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work HSR No. NS-16
Supply of 11KV pin insulator with pin with all labour and material required to the complete the job included the fixing the same on existing channels up to entire satisfaction of the Engineer-in-Charge of the works. HSR No. NS-17
Supply of LT insulator with pin with all labour and material required to the complete the job included the fixing the same on existing channels up to entire satisfaction of the Engineer-in-Charge of the works. HSR No. NS-18
Supply of LT AB cable including the cost of i-bolt for holding of cable etc. including required material to erect on existing PCC pole complete in all respect up to entire satisfaction of Engineer-in-charge of the work. LT AB cable 95+ 70mm2 HSR No. NS-19
Supply of LT AB cable including the cost of i-bolt for holding of cable etc. including required material to erect on existing PCC pole complete in all respect up to entire satisfaction of Engineer-in-charge of the work. LT AB cable 50+ 35mm2 HSR No. NS-20
Supply of LT XLPE Single core armoud cable 50mm2 as per satisfaction of Engineer-in-Charge of the work. HSR No. NS-21
Supply of LT XLPE Single core armoud cable 95mm2 as per satisfaction of Engineer-in-Charge of the work. HSR No. NS-22
Supply of V-shape X-arm on PCC poles as per state electricity Nigam design and requirement it should be made out of MS channel size 75 x 40 x 6mm complete in all respect . HSR No. NS-23
Supply of Top Hammer as per satisfaction of Engineer-in-Charge of the work. HSR No. NS-24
Supply of LT Fuse Unit Board as per satisfaction of Engineer-in-Charge of the work. HSR No. NS-25
Supply of earthing rod with GI Strip 25 x 6 & GI Plate 40mm dia complete in all respect upto the entire satisfaction of the Engineer in Charge of work HSR No. NS-26
Supply of MS D Strap as per satisfaction of Engineer-in-Charge of the work. HSR No. NS-27
Supply of lighting arrestor model ALPRO / Alastem / LEMCO make suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resitar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. HSR No. NS-28
Supply of T/F plateform set as per satisfaction of Engineer-in-Charge of the work. HSR No. NS-29
Erectioning 4 pole with 4 nos stay complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-30
Erectioning H pole with 2 nos stay 11 mtr complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-31
Erectioning 11 mtr long PCC pole complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-32
Erectioning of stay set complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-33
Erectioning of 25 KVA transformer with P/M S/STN complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-34
Erectioning of 63 KVA transformer with P/M S/STN complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-35
Erectioning of 100 KVA transformer with P/M S/STN complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-36
Erectioning of 11KV gang operated switch for 11 mtr pcc pole conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing 'H'pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works. HSR No. NS-37
Erectioning of Cable Box O/D HSR No. NS-38
Erectioning of HT XLPE cable including the cost of i-bolt for holding of cable etc. including required material to erect on existing PCC pole complete in all respect up to entire satisfaction of Engineer-in-charge of the work. 185sqmm 2 HSR No. NS-39(i)
Erectioning of Single phase meter complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-40
Erectioning of 3 phase meter complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-41
Erectioning of LT AB Cable 50+35mm2 complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-42
Erectioning of LT AB Cable 95+70mm2 complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-43
Erectioning of LT XLPE single core armod 50mm2 complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-44
Erectioning of LT XLPE single core armod 95mm2 complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-45
Sagging and stringing ACSR complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-46
Sagging and stringing GSL 8 SWG complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-47
Erectioning of LA Set complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-48
Erectioning of LA fuse unit board complete in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-49
D/o 100 KVA T/F with P/M S/STN in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-50
D/o 50 KVA T/F with P/M S/STN in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-51
D/o 25 KVA T/F with P/M S/STN in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-52
D/o Pcc pole 9 mtr long in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-53
D/o Iron Pole in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-54
D/o PCC pole 11 mtr long in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-55
D/o H pole with 2 nos stay in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-56
D/o 4 pole with 4 nos stay in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-57
D/o ACSR 50mm2 (3SWG) in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-58
D/o HT AB cable 185+240mm2 Split up in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-59
D/o HT AB cable 185+240mm2 in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-60
D/o HT XLPE cable 50mm2 in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-61
D/o HT XLPE cable 95mm2 in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-62
D/o HT XLPE cable 185mm2 in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-63
D/o Single phase meter in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-64
D/o LT AB Cable 50+35 mm2 in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-65
D/o 3 phase meter in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-66
D/o PVC 4/C Cable 16mm2 in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-67
D/o PVC 3.5/C Cable 95mm2 in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-68
D/o LT XLPE Single core armod 50mm2 in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-69
D/o GO Switch in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-70
D/o ACSR 5 SWG in all respect upto the entire satisfaction of Engineer-in-Charge. HSR No. NS-71
Loading Unloading of PCC Pole of 11 mtr HSR No. NS-72
Fabrication charges HSR No. NS-73
Note:- 1. In case material is not provided by the UHBVN authority the contractor will arrange the material as per UHBVN specification, approved make of UHBVN authority, get it dully inspected by UHBVN authority. 2. The final inspection will be done by the Chief Electrical Inspector at his own level by contractor. 3. The contractor will arrange NAC from UHBVN limited at his own level before taking the work in hand as per The Chief Engineer Electrical PWD B&R Chandigarh instructions/direction.
M R CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .