Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.4 LAccepted-AOC | ₹25.4 L Quoted ₹27.3 L | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER |
| 2 | 2₹29.7 L+₹2.4 L (8.82%)Rejected-Finance | ₹29.7 L+₹2.4 L (8.82%) | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 3 | 3₹31.8 L+₹4.5 L (16.5%)Rejected-Finance | ₹31.8 L+₹4.5 L (16.5%) | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 4 | 4₹32.0 L+₹4.7 L (17.2%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | ₹32.0 L+₹4.7 L (17.2%) | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 5 | 5₹32.4 L+₹5.1 L (18.9%)Rejected-Finance 65 6 518 B 1 HIMACHAL NAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | ₹32.4 L+₹5.1 L (18.9%) | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| Sl No | Description | Qty | Unit | KALPANA INFRA PROJECTS L1 | SUPREET CONSTRUCTIONS L11 | P VENKATA RAO L13 | AYYAPPA CONSTRUCTIONS L8 | SREE DURGA INFOTECH L2 | VIJAYA DURGA CONSTRUCTIONS L3 | ANUJ INFRA L12 | M/S Jayalakshmi Constructions L7 | HARSHITHA INFRA L6 | LALITHA SAI INFRA L5 | P JAGANNADHARAJU L9 | S A R CONSTRUCTIONS L10 | SAMPATH ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc except light fitting. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. | 578 | Point | 9 ₹5,202 Lowest | 100 ₹57,800 | 50 ₹28,900 | 35 ₹20,230 | 10 ₹5,780 | 25 ₹14,450 | 80 ₹46,240 | 60 ₹34,680 | 80 ₹46,240 | 99 ₹57,222 | 25 ₹14,450 | 40 ₹23,120 | 20 ₹11,560 |
| 2.00 | Taking down unserviceable main switches, DBs, bus bars chambers any capacityincluding all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed. | 96 | Each | 9 ₹864 Lowest | 100 ₹9,600 | 95 ₹9,120 | 50 ₹4,800 | 80 ₹7,680 | 100 ₹9,600 | 70 ₹6,720 | 70 ₹6,720 | 80 ₹7,680 | 90 ₹8,640 | 10 ₹960 | 65 ₹6,240 | 10 ₹960 |
| 3.00 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. | 1,000 | RM | 9 ₹9,000 | 60 ₹60,000 | 13 ₹13,000 | 12 ₹12,000 | 20 ₹20,000 | 10 ₹10,000 | 25 ₹25,000 | 20 ₹20,000 | 60 ₹60,000 | 18 ₹18,000 | 10 ₹10,000 | 25 ₹25,000 | 5 ₹5,000 Lowest |
| 4.00 | M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) surface fitted type including Flush type metal GI/PVC boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed.
(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) | 140 | Point | 250 ₹35,000 Lowest | 905 ₹1,26,700 | 830 ₹1,16,200 | 875 ₹1,22,500 | 800 ₹1,12,000 | 950 ₹1,33,000 | 850 ₹1,19,000 | 750 ₹1,05,000 | 650 ₹91,000 | 720 ₹1,00,800 | 550 ₹77,000 | 960 ₹1,34,400 | 600 ₹84,000 |
| 5.00 | All as per item No. 04 above but for One light point controlled by two Nos two way switch complete ditto | 24 | Point | 250 ₹6,000 Lowest | 905 ₹21,720 | 890 ₹21,360 | 925 ₹22,200 | 1,050 ₹25,200 | 1,100 ₹26,400 | 950 ₹22,800 | 780 ₹18,720 | 550 ₹13,200 | 720 ₹17,280 | 750 ₹18,000 | 960 ₹23,040 | 600 ₹14,400 |
| 6.00 | All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto | 165 | Point | 250 ₹41,250 Lowest | 905 ₹1,49,325 | 930 ₹1,53,450 | 925 ₹1,52,625 | 800 ₹1,32,000 | 950 ₹1,56,750 | 875 ₹1,44,375 | 730 ₹1,20,450 | 650 ₹1,07,250 | 720 ₹1,18,800 | 575 ₹94,875 | 960 ₹1,58,400 | 600 ₹99,000 |
| 7.00 | All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto | 25 | Point | 250 ₹6,250 | 905 ₹22,625 | 320 ₹8,000 | 225 ₹5,625 | 75 ₹1,875 Lowest | 100 ₹2,500 | 300 ₹7,500 | 250 ₹6,250 | 160 ₹4,000 | 108 ₹2,700 | 100 ₹2,500 | 430 ₹10,750 | 100 ₹2,500 |
| 8.00 | All as per item No. 04 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLSH (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLSH (ISI marked) as earth lead complete ditto | 130 | Point | 300 ₹39,000 | 1,050 ₹1,36,500 | 1,150 ₹1,49,500 | 1,120 ₹1,45,600 | 1,200 ₹1,56,000 | 1,100 ₹1,43,000 | 1,150 ₹1,49,500 | 800 ₹1,04,000 | 150 ₹19,500 Lowest | 900 ₹1,17,000 | 850 ₹1,10,500 | 1,320 ₹1,71,600 | 700 ₹91,000 |
| 9.00 | M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch.
(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.
(ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) | 40 | Point | 300 ₹12,000 Lowest | 1,200 ₹48,000 | 900 ₹36,000 | 825 ₹33,000 | 950 ₹38,000 | 1,300 ₹52,000 | 1,220 ₹48,800 | 800 ₹32,000 | 655 ₹26,200 | 720 ₹28,800 | 600 ₹24,000 | 955 ₹38,200 | 800 ₹32,000 |
| 10.00 | All as per item No. 09 above but for One light point controlled by two Nos two way switch complete ditto | 3 | Point | 300 ₹900 Lowest | 1,200 ₹3,600 | 980 ₹2,940 | 925 ₹2,775 | 1,200 ₹3,600 | 1,500 ₹4,500 | 1,220 ₹3,660 | 820 ₹2,460 | 655 ₹1,965 | 811 ₹2,433 | 600 ₹1,800 | 955 ₹2,865 | 800 ₹2,400 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Oct 2025, 6:00 pmClosed
GARRISON ENGINEER (NAVAL BASE)
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
MAINTENANCE REPAIR AND REPLACEMENT OF INTERNAL ELECTRICAL FITTINGS, FIXTURES, DBS AND SUB MAIN WIRING AT INHS KALYANI AREA AND CONNECTED E/M WORKS AT SECTOR J, K, L, M (NAUSAINIK VIHAR AREA) AT DOLPHIN HILL AREA UNDER GE (NB) VISAKHAPATNAM
2025_MES_733908_1
C/8516/25-26/E8 TOKEN 37 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹90,000
Yes
3 Jan 2026
6 Oct 2025
4 Nov 2025
6 Oct 2025
28 Oct 2025
21 Oct 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc except light fitting. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers any capacityincluding all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) surface fitted type including Flush type metal GI/PVC boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
All as per item No. 04 above but for One light point controlled by two Nos two way switch complete ditto
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 04 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLSH (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLSH (ISI marked) as earth lead complete ditto
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 09 above but for One light point controlled by two Nos two way switch complete ditto
All as per item No. 09 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 09 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 09 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLSH (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLSH (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F steped type modular fan regulator ,100/120 W 1/ 2 module complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i)Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (ii) Four runs of 10 sqmm and two runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
S & F repairs of single core 1.5 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLSH copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 2.5 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLSH copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 4 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLSH copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 6 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLSH copper conductor cable 1100 Volts [ISI marked ] drawn through existing Sub main wiring complete all as specified and as directed.
S & F repairs of single core 10 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLSH copper conductor cable 1100 Volts [ISI marked ] drawn through existing /Sub main wiring complete all as specified and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 1.5 sqmm complete all as specified and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 2.5 sqmm complete all as specified and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 4 sqmm complete all as specified and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 6 sqmm complete all as specified and as directed.
S & F Single phase sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, C-curve complete all as specified and as directed.
S & F in repairs AC Plug for two pin and earth plug and socket enclosure complete all as specified and as directed.
S & F in repairs AC Socket for two pin and earth plug and socket enclosure complete all as specified and as directed.
S & F in repairs 3 pin male top plug, 5 Amps for electrical fittings complete all as specified and as directed.
S & F in repairs 3 pin male top plug, 15 Amps for electrical fittings complete all as specified and as directed.
S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed.
S & F Distribution Board, TPN 8 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed.
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09 complete all as specified and as directed.
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed.
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed
Supply, fixing commissioning and testing in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed
Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed
Supply, fixing, commissioning and testing in repair MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed
Supply, fixing, commissioning and testing MCB SPN 40 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed
Supply, fixing, commissioning and testing in repairs MCB SPN 40 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed
Supply, fixing, commissioning and testing MCB Four pole 63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed
Supply, fixing, commissioning and testing in repairs MCB Four pole 63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
Supply and fix in repair fan capacitors of 2.5 Mfd complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
S & F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole two way 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 16 amp 240 volts, complete all as specified and as directed.
S & F in repairs bell push flush type, 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.
S & F in repairs Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts, universal with PVC rectangluar gang box complete all as specified and directed.
S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal with PVC rectangluar gang box complete all as specified and as directed.
S & F in repair Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
S & F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed.
S & F in repairs switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F in repairs switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs modular bell push 6 amp 240 volts1 module,complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs stepped type modular fan regulator ,100/120 W, 1/ 2 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 1 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 2 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 3 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 4 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 6 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 8 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 12 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 1/2 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 3 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 4 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 6 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 8 module complete all as specified and as directed.
S & F in repair 1/2 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 3 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 4 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 6 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 8 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S & F in repairs LED Drive 36/40 watts as per site requirement complete all as specified and as directed.
S & F in repairs LED Drive 12-15 watts as per site requirement complete all as specified and as directed
S & F in repairs LED Drive 18-24 watts as per site requirement complete all as specified and as directed
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 10 Watt, Lumen ≥ 1000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed.
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 20 Watt, Lumen ≥ 2000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed.
S & F in repairs LED light fittings, ceiling mounted, panel type, white powder coated CRCA body, PC lens, Approx dimensions 2'x2', 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,min IP 40 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repairs LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI > 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repairs LED downlight, Recess mounted round, die cast aluminium housing, 12 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repairs LED downlight, Recess mounted round, die cast aluminium housing, 15 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repairs LED downlight, Surface mounted round die cast aluminium housing, 12 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. [Make: Jaquar Cat No IDL-WHT-LNRO02R012SC or equivelant of make as per list of manufacturer]
S & F in repairs LED downlight, Recess mounted round, die cast aluminium housing, 18 Watt as per the existing cutout, 200-275mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repairs LED downlight, surface mounted round, die cast aluminium housing, 15 Watt as per the existing cutout, 200-275mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed.
S & F in repair 7 Watt, LED picture light fittings, having 270 Lumen and 3000K, correlated colour temperture, decorating light with all accessories, internally pre-wired and connecting up complete all as specified and directed.
S & F in repairs LED Bulb, 9 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
S & F in repair LED Strip light, 24V DC, 25W, 8mm width with IP 20 protection, uniform light distribution and long lasting adhesive and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed.
S & F in repairs LED Power Supply for IP20 strip light, 24V DC, 30 Watt suitable for strip lights and connecting up complete all as specified and directed.
S & F in repairs LED tube rod, T8, 20 Watt, polycarbonate diffuser, 1200mm length, CCT: WW/CW complete all as specified and directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 10"x8" for fixing switches, sockets & regulator etc complete all as specified and as directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 6"x4" for fixing switches, sockets & regulator etc complete all as specified and as directed.
S & F in repairs Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc.. including re-inserting existing serviceable cables complete all as specified and directed.
S & F in repairs 25-35 Sqmm size Aluminium thimbles to terminate electrical wires/cables or connections in a professional manner to minimize current leakage and to avoid overheating or electrical failures due to loose connection complete all as specified and as directed.
S & F in repairs 4-10 Sqmm size Copper thimbles to terminate electrical wires/cables or connections in a professional manner to minimize current leakage and to avoid overheating or electrical failures due to loose connection complete all as specified and as directed.
Note :- 1. In compliance with condition 26 of IAFW-2249 (General Condition of Contract) for safety purpose Electrician employed by the contractor for this work shall have Industrial training Institute pass certificate from a recognized institute in relavant trade with 3 years experience in relevant field or 10th Class pass Certificate having 10 years of practical experience in relevant field . Before commencement of work contractor shall submit the name of electrician alongwith necessary documents in support of their qualification and practical experience to the Engineer-in-Charge for approval of accepting officer. Incase any changes of manpower require during currency of tender ,fresh approval shall be taken from accepting officer. 2. Before commencement of work contractor shall submit valid electrical license in accordance with Cl No 23 of Sch “A” Notes of contract agreement. 3. Supervisor for execution of above mentioned work employed by the contractor shall also posses supervision certificate of competency issued by concerned State Govt where the works are to be executed
SREE DURGA INFOTECH (BID ID -3461306)
VIJAYA DURGA CONSTRUCTIONS (BID ID -3461344)
SAMPATH ENTERPRISES (BID ID -3459907)
LALITHA SAI INFRA (BID ID -3461179)
HARSHITHA INFRA (BID ID -3461847)
M/S Jayalakshmi Constructions (BID ID -3461669)
AYYAPPA CONSTRUCTIONS (BID ID -3461283)
P JAGANNADHARAJU (BID ID -3461299)
S A R CONSTRUCTIONS (BID ID -3461295)
SUPREET CONSTRUCTIONS (BID ID -3460467)
ANUJ INFRA (BID ID -3461561)
P VENKATA RAO (BID ID -3461260)
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
Tender_8516.pdf
Tender Documents • 1.19 MB
BOQ_821744.xls
BOQ • 0.39 MB
Corrigendum8516.pdf
PDF • 0.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .