Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC 108 AND 111 COMMERCIAL ROAD 133001 | AMBALA | HARYANA | 133001 | ₹36.6 L | L1 | Accepted-AOC LOA |
| 2 | L2₹37.2 LRejected-Finance C 109 POCKET C SECTOR 2 DSIIDC INDUSTRIAL AREA BAWANA DELHI DELHI 110039 UDYAM DL 06 0004527 | NORTH DELHI | DELHI | 110039 | ₹37.2 L | L2 | Rejected-Finance Highest |
| 3 | L3₹37.4 LRejected-Finance | ₹37.4 L | L3 | Rejected-Finance Highest |
| Sl No | Description | Qty | Unit | Instruments and Equipment Co L1 | AAR KEY INDUSTRIES L2 | H S Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00 | [24.13.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate] | 40 | Metre | 2,006 ₹80,240 | 2,010 ₹80,400 | 2,100 ₹84,000 |
| 2.00 | SITC of 800 KVA 3-Phase Oil Cooled Servo Motor Operated Automatic Voltage Stabilizer, Input- 340-480 V. AC Three Phase, Output-415 V. AC Three Phase., Stability-±1%, Efficiency-More than 95%, Cooling-Oil Cooled with first filling of oil, as per IS-335, Distortion Introduced- -NIL-, Frequency-50 Hz , Class of Insulation-‘A’, Construction-Indoor type, No. of Servo Motor.-03 Nos. (01 for each phase), Digital control cards.-03 Nos. (01 for each phase), Auto variable Transformer-03 Nos. (As per IS-5142), Buck Boost Transformer-03 Nos. (As per IS-2026), Ambient Temp.- 45ºC, Duty Cycle-Continuous, Power Factor-Suitable for all Power factor load., Control Card-Micro-Controller based Software driven fully, Solid state Digital control card with static Switching-avoiding Electromagnetic relays. Insulation Resistance. -As per IS-9815, Mode of operation-Auto Mode Manual Mode with Press switches., H.V. Break Down Test-Shall with stand 1.5KV rms for 1 minute, Response Time-Less than 20ms, Testing Standards - IS:9815 and IS: 2026, Mains Indicators - Large 19 mm Red, Yellow, Blue for each Phase, Output Indication - Individually on each phase(Both Input and O/Put, Type.-Unbalanced Supply, Unbalanced Load, In addition to above the stabilizer shall be provided with following facilities. 1. Mains indicator in each phase. 2. Digital Voltmeter to read Input and output in each phase. 3. Auto/Manual operation facility. 4. Input Low/High voltage indication. 5. Input/output connecting terminals. 6. Lifting Lugs 7. Drain valve 8. Oil Level Gauge 9. Rating Plate 10. Earthing Terminals 11. Wheels for Uni-Directional movement PROTECTIONS 1. Automatic Low/High Voltage Cut off in the output. 2. Single and Reverse Phasing Protection. 3. Automatic Overload and short circuit Protection 4. Automatic Phase sequence Correction Facility Bypass Arrangement - The Stabilizer shall be provided with Four Pole ON Load Bypass Switch with inter connections to isolate the AVR and Bypass the mains supply, including end terminations and petty material Required for installation. complete in all respect up to entire satisfaction of Engineer in charge of Work. MAKE - AARKEY/IECO/HI -SHINE. | 1 | Each | 35,76,000 ₹35.8 L | 36,40,000 ₹36.4 L | 36,60,000 ₹36.6 L |
Tender Value
₹35.5 L
EMD Value
₹70,960
Closing Date
8 Jan 2026, 5:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Upgradation of Civil Hospital at Naraiangarh from 50 Bedded to 100 Bedded along with residential accommodation in Ambala Distt (Pdg. 800 KVA Automatic Servo Voltage Stabilizer).
2026_HRY_494316_1
2026CF9A24B2 6375 40F7 BE03 AEEFFE9D4899663BAR
Open Tender
Civil Works
460 days
Ambala
Upgradation of Civil Hospital at Naraiangarh from 50 Bedded to 100 Bedded along with residential accommodation in Ambala Distt (Pdg. 800 KVA Automatic Servo Voltage Stabilizer).
2 documents required · 2 mandatory
₹5,000
₹70,960
Yes
18 Feb 2026
1 Jan 2026
9 Jan 2026
2 Jan 2026
8 Jan 2026
2 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer Electrical Division PWD B&R Br., Ambala Cantt
Name of Work: Upgradation of Civil Hospital at Naraiangarh from 50 Bedded to 100 Bedded along with residential accommodation in Ambala Distt (Pdg. 800 KVA Automatic Servo Voltage Stabilizer).
Estimated Cost Rs. 35.48 lacs
Name of the Bidder/ Bidding Firm / Company :
Sl. No. HSR Items / Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.