Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.8 L+₹2.2 L (22.8%)Rejected-Finance | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹17.7 L+₹8.1 L (84.6%)Rejected-Finance | L3 | Rejected-Finance Third Lowest | |
| 4 | L4₹18.1 L+₹8.5 L (88.2%)Rejected-Finance | L4 | Rejected-Finance Fourth Lowest | |
| 5 | L5₹18.7 L+₹9.1 L (94.7%)Rejected-Finance 97 ABROL NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Fifth Lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
7 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major S N Gaikwad
Holta Cantt Palampur
REPAIR MAINTENANCE OF SECURITY LIGHTS AND OTHER MISC EM WORKS AT PALAMPUR MIL STN
2023_MES_608523_1
GEP-35/2023-24
Open Tender
Civil Works
Item Rate
180 days
Palampur Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹40,000
23 Sept 2023
10 Jul 2023
11 Aug 2023
10 Jul 2023
7 Aug 2023
24 Jul 2023
Amount
Labour only for checking the serviceability of the different spares / components / parts of security light fittings/post top lantern light fittings (LED, flood light/focus light etc, any wattage/capacity) of any description and fixed in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed.
NOTES (i) Replacement of parts i.e LED driver for Flood light/ LED/Focus light fittings any wattage & capacity, if any required at site, shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ as ‘supply only. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor’s quoted rates for Schedule `A' /BOQ Srl item No 12 is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed.
Disconnecting and taking out existing unserviceable light fitting of any description and in any position on poles and S&F 20W LED Post top lantern complete accessories to be fixed on pole/wall including connecting the fitting to control switch at the bottom of the pole with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor copper conductor cable complete all as specified and directed. Make: Bajaj Cat Part No- BGCT W4 LED WW/Crompton Cat NoL PTH-20 CDL/Havells Cat Part No RUBYPT25WLED830SSYMTOPC
Disconnecting and taking out existing Flood light fitting of any description and in any position on High mast 16.0/12.0 mtr height poles and Supply, fixing & testing 200 W LED flood light with pressure die-cast aluminium housing, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. Make- Philips Cat NoBVP184 LED 196/197/184 CW / NW / WW FG WB 200W PSU/Bajaj Cat part No BJFL 200W LED/Havells Cart No JETAIRISMAXFL200WLED757PWBLTG Note : GI pipe bracket and clamps if required shall be measured and paid separately.
Disconnecting and taking out existing Street light fitting of any description and in any position on Street light poles and Supply, fixing & testing 45W LED street light fitting IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens embdded PC cover complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed.(Make- Philips Cat NoBRP031 LED45 CW / WW MR PSU GR DX Bajaj Cat Part No ENXT P 54L WH CR PC SD/Havells Cart Part No ENDURASUNDOWNSL45WLED765PASYBOTG Note : GI pipe bracket and clamps if required shall be measured and paid separately.
Disconnecting and taking out existing Street light fitting of any description and in any position on Street light poles and Supply, fixing & testing 60W LED street light fitting IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. (Make- Philips Cat No BRP032 LED60 CW / WW SLR GR PSU Bajaj Cat Part No ENXT P 72L WH CR PC SD/Havells Cat part No ENDURAPEARLNEOSL 60WLED757PASYTOPCAST Note : GI pipe bracket and clamps if required shall be measured and paid separately.
Disconnecting and taking out existing Street light fitting of any description and in any position on Street light poles and Supply, fixing & testing 90W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed.(Make- Crompton Cat No TRP-411-90-57-SL-GL-NSG / Bajaj Cart No BRTFG 90W LED CRor/ Havells cat part No ENDURAOMNIPLUSSL90WLED757SASYTOPC Note : GI pipe bracket and clamps if required shall be measured and paid separately.
Supply and fixed in repair LED Driver suitable for street/flood light 45 to 48 Watt working on 230 volts AC supply, complete all as specified and directed.
Supply and fixed in repair LED Driver suitable for street/flood light 50 to 60 Watt working on 230 volts AC supply, complete all as specified and directed.
Supply and fixed in repair LED Driver suitable for street/flood light 70 to 90 Watt working on 230 volts AC supply, complete all as specified and directed.
Supply and fixed in repair LED Driver suitable for street/flood light 100 to 150 Watt working on 230 volts AC supply, complete all as specified and directed.
Taking down existing unserviceable bracket complete and S&F 25 mm dia GI light grade pipe , 1.2 metre long bent to shape at 120 degree angle with bracket bent to shape by cutting & welding as required & directed and fixed to pole with two No,s of FI clamps 40x5 mm to be tightened with bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply & Fixing repairs cable junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 205x255x112 mm and suitable for LT under ground cable any size/capacity including bracing clamp,bolts,nuts & washers. (Make Hensel/ model No-KF2525B or Sintex or equivalent as approved)
Dismantling and taking out old un-serviceable Non-integral light fittings from 13.5/16 mtr High mast tower with connection and unserviceable parts ,such as Drivers,LED lamps ,LED Fittings etc and replace the same and refitting in its position including servicing the double drum winch and greasing the 5 mm dia steel wire rope, wheels,operating handles with all parts and equipments of existing High mast Tower ,fitting ,Allignment upto length, testing complete in all respect after the high mast tower mounted all as specified and directed.
M&L for replacement of Steel wire rope of size 5 mm dia ( as per existing) with required nuts,bolts and hooks including taking down old U/S steel wire rope from different high mast towers.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
All as item No. 15 above, but not exceeding 3 mtr in depth.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning to undergound cable with using fine river sand and gently punning for cushioning to cable complete all as specified and as directed. Note:-for the purpose of payment only punned thickness will be measured.
M&L old size brick class "B" as in cable protection laid dry,flat,transversally along the length of cable on sand cushioning with width equalto length of the brick complete all as specified and as directed.
M&L PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal including necessary formwork and fair finishing to exposed surface without using extra cement complete all as specified and directed.
M&L cement concrete (1:3:6) type C2 using 40mm graded crushed stone aggregates for foundation of poles / struts / stays etc complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Material and labour for prepration of old concrete surface of HT poles, 11 metres high including PCC coping, removing old paint particles and apply two coats of cement base paint on the surface of pole and PCC coping, applying two coat of aluminium paint on cross arms, bracing, supports, clamps, eye hooks, security light bracket clamp etc and marking black and white strips with synthetic enamel paint, 30 cm wide, alternatively upto 1.5 mtr above the coping of pole starting with black strip complete, all as specified and directed. Note. (i) The quoted rate shall include marking of numbers on each HT pole as per direction of Engr in-Charge. (ii) The quoted rates includes the cost of repairing of coping in cement mortar 1:3 finishing surfaces even and smooth without using extra cement.
Trimming of tree branches from LT overhead line to branch 2 mtr up to both side & re-stretching of ACSR conductor and earth wire of any size and type on LT poles including disconnecting and rebinding with insulators with suitable size of binding wire after restretching, connecting jumpers, adjusting line deviders and disposal tree branches as per direction by Engr-in-Charge complete including removing and refixing of UG cable /service wires to the ACSR conductor complete. (Note- Pole to pole length shall be measured and paid as one run)
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 16 sq.mm 4 core including taking out old unserviceable cable complete all as directed by Engineer-in-charge.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 10 sq.mm 4 core including taking out old unserviceable cable complete all as directed by Engineer-in-charge.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 16 sq.mm 2 core including taking out old unserviceable cable complete all as directed by Engineer-in-charge.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 10 sq.mm 2 core including taking out old unserviceable cable complete all as directed by Engineer-in-charge.
S&F 50mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
Cutting and removing existing wild grass,vegetation, creepers, small plants / bushes etc clamping up towards the poles and stays etc including cleaning bottom surface area of pole &stay not less than 1m x 1m by surface dressing of earth outside and inside substations, perimeter fencing around pump house area, and in drains surrounding area from site complete all as specified and directed by Engineer-in-charge.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connecting to GI earth wire of size 4mm size by means of bolts, nuts, check nuts and protected by provision of GI medium grade pipe of 15mm bore including provision of 40mm tk cover of RCC (1:2:4) reinforced with XPM (wt no less than 4Kg/sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm dia pipe for watering of suitable length placed on tp edge of earth plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and excavation and earthwork in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as per plate No. 3 of SSR 2009 Part-I and connecting to earth test point all as specified and directed by Engineer-in-Charge and including testing on completion.
Note:-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B1, 80mm thick reinforcement with 8mm TOR steel @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item. (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe up to 7.50m and the rate includes in the unit rate of item. (iii) Earth pit chamber and RCC cover shall be painted with red paint over a primer coat and the rate includese in the unit rate of item. (iv) The earth chamber shall be constructed 5m away from the edge of the bldg pit and the cost of the same is deemed to be included in the rate for this item.
M/S MALHI CONSTRUCTIONS
M/S SAROOP ELECTRICAL & MECHANICAL WORKS
dinesh enterprises
Eshaan Construction Co.
RATTAN CHAND CHANDAN AND CO
M/S SEALINE BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .